Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.8 LAccepted-Finance 154 A BARASIROHI NEAR IIT KANPUR KALYANPUR KANPUR NAGAR UTTAR PRADESH 208016 | KANPUR NAGAR | UTTAR PRADESH | 208016 | L1 | Accepted-Finance Above Estimate. | |
| 2 | L2₹15.8 L+₹4,200.80 (0.27%)Accepted-Finance | L2 | Accepted-Finance Above Estimate. | |
| 3 | L3₹15.8 L+₹5,251 (0.33%)Accepted-Finance | L3 | Accepted-Finance Above Estimate. |
Tender Value
Refer Docs
EMD Value
₹15,800
Closing Date
10 Apr 2025, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Gonda
220 KV Substation Gonda Campus, Jail Road Gonda
WORK
2025_UPTCL_1015881_1
23/ETC(GD)/2024-25
Open Tender
Electrical Works
Fixed-rate
45 days
Bahraich
Please refer Tender documents.
3 documents required · 3 mandatory
₹590
EE ETD
₹15,800
19 Jul 2025
10 Mar 2025
10 Apr 2025
10 Mar 2025
10 Apr 2025
10 Mar 2025
Amount
Troubleshooting/rectification/restoration/configuration of the Siemens make SCADA System installed at 220 KV Sub-Station Bahraich
SCADA HMI Troubleshooting/rectification of the Siemens make SCADA substation Automation System installed at 220kV Bahraich, The following work included to make SCADA System Healthy (A) Replacing the defective Fiber patch cords/CAT-5 cables, if any. (B) Checking & rectifying the healthiness of IEC61850-3 compliance Ethernet Switches. (C) Rectification /checking healthiness of the old backup installed at the system, if any. (D)Checking the all-healthiness communication in between protection relays and SCADA system. (E) Checking the SLD communication failure on SCADA HMI. F) Checking the real time Analogue Values on the SCADA System. (G) Checking and rectifying the control command issues from SCADA to BCPUs, if any. subject to CB /ISO must be control from the respective BCPUs. (H) Installation of OS window 10 (Long time support) and updated HMI (WinCC+SCC) (J) Reinstallation of old backup in Main and Standby sever SCADA HMI-I & HMI-II if required. All above required mentioned material will be provided by the contractor.
Bay Integration/configuration in the existing SICAM 230 ver 7.11 make SCADA of 33 kV Bays, work includes as below: (A) Creation of Single line Diagram(SLD) Graphics. (B) Database point configuration as per the existing database version 7.11. (C) Alarm/EVENT/REPORT templates veneration. (D) Real time report page generation for Hourly/daily/monthly). (E) Soft Interlock logics templates generation. (F) Buffered/Un-buffered Report Control Block updation as per the BCPUs files. Following are the details of 132 KV Bays for integration/configuration. 1. 33 kV Bay No-313 (33 KV Bhakla DOC 31.10.2020) 2. 33 kV Bay No-314 (33 KV Medical DOC 20.01.2020) 3. 33 kV Bay No-315 (33 KV TA Green DOC 11.02.2019)
Mapping/Configuration of the ICD files variables of IEC61850 base relays in existing database software of feeder bays. (01 Job includes 01 Relay per Bay work)
Supply and Installation of IEC61850 based Ethernet Switch suitable for existing SAS system with sufficient Fiber/RJ45 ports..
Gateway Configuration and testing validation work of the above mentioned feeders to send the real time data to SLDC Lucknow and SLDC Modipuram.
Supply and installation Various type of Fiber patch LC to LC, LC to ST MM patch cords of different lengths as required.
Troubleshooting/rectification/restoration/configuration of the Siemens make SCADA System installed at 132 KV Sub-Station Kaiserganj
SCADA HMI Troubleshooting/rectification/restoration of all healthy 132 KV/33 KV Feeders real time data at local SCADA HMAI as previously running on the SCADA also rectifying the issue related IEC 1850 variable and buffered report control block to mate healthy communication on IEC-104 protocol over TCP/IP to SLDC Lucknow.
Configuration of the stand by CPT cum gateway in the existing SICAM, Siemens make SCADA system. Mapping the IEC61850 variables as per the field signals in the gateway to make the communication on IEC-104 protocol over TCP/IPs to Modipuram SLDC. Firmware updation for the Network protocol (NTP) and configuration the time synch. Validation of the real time data to Modipuram in between Relays / BCUS.
AR POWER AUTOMATION (BID ID -5112741)
exSel Corporation (BID ID -5112869)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .