Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | ₹8.4 L | L1 | Accepted-AOC L1 Contractor |
| 2 | Rejected-Technical BUS STAND ROAD BARARA AMBALA | BARARA | AMBALA | - | - | Rejected-Technical despite several chances, valid shortfall documents has not been uploaded by you. Therefore, Bid submitted by you for this tender has been rejected |
| 3 | Rejected-Technical | - | - | Rejected-Technical despite several chances, valid shortfall documents has not been uploaded by you. Therefore, Bid submitted by you for this tender has been rejected |
| Sl No | Description | Qty | Unit | shiv enterprises L1 |
|---|---|---|---|---|
| 1.00Laying of foundations for erecting of tower of 66kv Line on Labour rates Lump-Sum basic as per PSPCL drawings including excavation, placement of steel reinforcement, concreting, stub setting, form work, centering shoring, shuttering back filling and other allied works required for setting stubs including the cost of sand and gravel complete in all respects as per PWD specifications crusher & sand to be arranged by the contractor. All other material i.e. Cement, Steel, Stub Setting templates etc. shall be provided by PSPCL from its stores at Bathinda, Verpal and Mandi Gobindgarh) free of Cost. | ||||
| 1.01 | Labour Charges involved in Stubbing of 2D-60 CW/TT 1303 type double circuit towers | 1 | No. | 1,80,585 ₹2.1 L |
| 2.00 | Transportation and erection of towers complete with all fittings including tack welding including all T&P (Welding Rods to be supplied by the contractor) & zinc rich paint touching wherever required (zinc paint to be supplied by the contractor) Installation of danger plates, No. plates, Phase Plates, Ckt Plates, Bird guard & Anti climbing devices etc on labour rate basis (220 KV) | 14.19 | MT | 1,40,276.63 ₹1.7 L |
| 3.00Pit Marking | ||||
| 3.01 | Angle Tower | 1 | No. | 1,500 ₹1,770 |
| 4.00 | Dismantlement & Reasagging of conductor size 0.4sq'' HTLS | 1.65 | SC Km | 1,24,718.85 ₹1.5 L |
| 5.00 | Dismantlement & Reasagging of conductor size 0.4sq'' ACSR | 1.65 | SC Km | 1,24,718.85 ₹1.5 L |
| 6.00 | Re-sagging of Earth Wire 7/2.24 mm | 1.65 | Km | 4,281.27 ₹5,051.90 |
| 7.00 | Dismantlement and Transportation and return of tower material complete with all fittings including all T&P 66KV in PSPCL store | 17.89 | MT | 1,16,642.8 ₹1.4 L |
| 8.00 | Transportaion of Cement from Central store Patiala, Steel from S&T store M. Gobind garh and carriage of Sand Crusher from Quarry and Difference of Material | 1 | Lump Sum | 16,100 ₹18,998 |
Updated dates
Tender Value
₹9.3 L
EMD Value
₹18,600
Closing Date
12 Jan 2026, 10:00 amClosed
ASE TL Division PSPCL Ludhiana
Quarter no 20, type 5, power colony 2 sarabha Nagar Ludhiana
shifting of 66 kV line in the premises of M S Apra Developers Pvt Ltd
2025_POWER_153809_1
04/TL Div LDH/2025-26
Open Tender
Power/Energy Projects/Products
60 days
Near Gill Road Ludhiana
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
₹18,600
Yes
7 Apr 2026
18 Nov 2025
13 Jan 2026
18 Nov 2025
12 Jan 2026
18 Nov 2025
Laying of foundations for erecting of tower of 66kv Line on Labour rates Lump-Sum basic as per PSPCL drawings including excavation, placement of steel reinforcement, concreting, stub setting, form work, centering shoring, shuttering back filling and other allied works required for setting stubs including the cost of sand and gravel complete in all respects as per PWD specifications crusher & sand to be arranged by the contractor. All other material i.e. Cement, Steel, Stub Setting templates etc. shall be provided by PSPCL from its stores at Bathinda, Verpal and Mandi Gobindgarh) free of Cost.
Labour Charges involved in Stubbing of 2D-60 CW/TT 1303 type double circuit towers
Transportation and erection of towers complete with all fittings including tack welding including all T&P (Welding Rods to be supplied by the contractor) & zinc rich paint touching wherever required (zinc paint to be supplied by the contractor) Installation of danger plates, No. plates, Phase Plates, Ckt Plates, Bird guard & Anti climbing devices etc on labour rate basis (220 KV)
Pit Marking
Angle Tower
Dismantlement & Reasagging of conductor size 0.4sq'' HTLS
Dismantlement & Reasagging of conductor size 0.4sq'' ACSR
Re-sagging of Earth Wire 7/2.24 mm
Dismantlement and Transportation and return of tower material complete with all fittings including all T&P 66KV in PSPCL store
Transportaion of Cement from Central store Patiala, Steel from S&T store M. Gobind garh and carriage of Sand Crusher from Quarry and Difference of Material
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
newspaper.pdf
Tender Documents • 1.08 MB
finaldnit.pdf
Tender Documents • 1.40 MB
BOQ_311668.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid