Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹91,220Accepted-AOC THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | L1 | Accepted-AOC L1 | |
| 2 | L2₹94,885+₹3,765 (4.13%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | Rejected-Technical BETHAL THIRUMALA TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695001 | - | Rejected-Technical L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical L4 |
Tender Value
₹1.1 L
EMD Value
₹2,700
Closing Date
29 Jul 2024, 5:00 pmClosed
Executive Engineer
Executive Engineer Thiruvananthapuram Corporation 695033
RE- ELECTRIFICATION OF ANGANWADI NO 28 SOUTH ROAD IN MUDAVANMUGAL WARD OF THIRUVANANTHAPURAM MUNICIPAL COPRPORATION
2024_LSGD_679824_3
EE(C)/PLAN FUND TENDER/2024-25 (03)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹2,700
Yes
17 Nov 2024
20 Jul 2024
31 Jul 2024
20 Jul 2024
29 Jul 2024
20 Jul 2024
Amount
1.10.1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch,modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A
1.14.1 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5sq.mm + 1x1.5 sq.mm earth wire
1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required.
1.56 Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess,including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings).
1.58 Supplying and fixing PVC batten/ angle holder including connection etc. as required.
od1761805/2022_2023 Supplying and fixing cast aluminium bulk head fitting with mesh guard with 7W LED bulb and giving connection etc. as required
od1761806/2022 2023Supply and providing the following types and power rated lamps in the existing fittings as required B22LED bulb 10 W
1.24.1 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modularswitches in recess etc as required.3 Module (100mmX75mm)
90.3.18.2Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut andwelded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required.32 mm dia with HG company fabricated clamps
90.3.20.3Supply & installation of light fittings on TW round block<br>Supply, conveyance installation testing andcommissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with allaccessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit thefitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wireconforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box typefixture
90.15.4.1Supply Conveyance, installation, testing and commissioning of 20W LED street light output greater than105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factorgreater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-castPowder coated housing,acrylic cover complete with THD Less than10%, power factor greater than 0.98,RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatlyaccessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be producedmentioning chip manufacturer)
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210 (cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
2.3.3Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V,on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator 12 way, Double door
2.10.1Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.2Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual currentcircuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
1.17.3Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.12Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in theexisting surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20mm
5.3 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, andproviding masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required.
90.14.1.2Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dustand vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panelassembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved designand requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gearcompartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outsfor mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus barchamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for thefabrication of panel assembly. The measurments will be taken the area of the complete sheets used forpanel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.16.1.3 Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
od1761809/2022_2023 Supply and fixing 32A backelite fuse base with HRC fuse link in the existing meter board and giving connections etc
od1761810/2022_2023 Supply and fixing 32A, 415 V, 2 way neutral link mounted on DMC/ SMC base in the existing meter board and giving connections etc.
od1761813/2022_2023 Supply and providing iron hook for binding service wire
ASOK ELECTRICALS
STEPHEN MOSES
SYNERGY POWER TECH
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1060157.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .