| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1Leak rectification | ||||||
| 1.001 | 22.6:Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/ sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. laying second layer of fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/ sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall and tucked into groove in parapet all around. d) fourth and final layer of brick tilling with cement mortar (which will be paid for separately. For the purpose of measurement the entire treated surface will be measured) | - | sqm | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) | - | sqm | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 26.29.1:Cleaning of reinforcement from rust from the reinforcing bars to give it a total
rust free steel surface by using alkaline chemical rust remover of approved
make with paint brush and removing loose particles after 24 hours of its
application with wire brush and thoroughly washing with water and allowing
it to dry, all complete as per direction of Engineer-In-Charge.Bars upto 12 mm diameter | - | metre | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | - | sqm | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | - | sqm | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | - | sqm | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | OD216209/2025-2026:Engaging coolie as labour for various works as per the direction of departmental officers at site | - | each | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 14.17: Raking out joints in lime or cement mortar and preparing the surface for repointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge | - | sqm | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 26.28.3:Chipping of unsound/weak concrete material from slabs, beams, columns etc.
with manual Chisel and/ or by standard power driven percussion type or of
approved make including tapering of all edges, making square shoulders of
cavities including cleaning the exposed concrete surface and reinforcement
with wire brushes etc. and disposal of debris for all lead and lifts all complete
as per direction of Engineer-In-Charge25 mm average thickness | - | sqm | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_1447852.xls
BOQ • 0.31 MB
PRELIMINARYAGREEMENTCOMMON.pdf
Tender Documents • 0.14 MB
ePay.pdf
Tender Documents • 0.01 MB
FIP.pdf
Tender Documents • 0.01 MB
Affidavit.pdf
Tender Documents • 0.31 MB
FOT.pdf
Tender Documents • 0.01 MB
SBD.pdf
Tender Documents • 1.64 MB
Download all tender documents and submit your bid