Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹80.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹83.0 L+₹2.0 L (2.46%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹85.6 L+₹4.6 L (5.72%)Rejected-Finance NEAR SHIV SHAKTI DHARAM KANTA SHIV PURAM FULSUNGA RUDRAPUR U S NAGAR UTTARAKHAND | UDAM SINGH NAGAR | UTTARAKHAND | 244712 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹85.9 L+₹5.0 L (6.14%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹88.5 L+₹7.5 L (9.29%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹86.9 L
Closing Date
20 Sept 2021, 6:00 pmClosed
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO. CWE /HILLS /PGH/35 OF 2021-2022 SPECIAL REPAIR OF OLD VINTAGE BER TRANSFORME, SERVO, HT OVER HEAD LINES WITH HT UNDER GROUND CABLE AND SHIFTING OF HT OVER HEAD LINE WITH HT UG CABLE NEAR PSI CHILDREN PARK UNDER GE PITHORAGARH
2021_MES_467088_2
CA NO CWE / HILLS / PGH/35 OF 2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
PITHORAGARH
Class C
10 documents required · 10 mandatory
₹1,000
GE PITHORAGARH
Yes
4 Oct 2021
16 Aug 2021
22 Sept 2021
16 Aug 2021
20 Sept 2021
8 Sept 2021
17 Aug 2021 - 6 Sept 2021
Amount
Dismantling of HT PCC/ steel tubular pole of any size and discription including coping, foundation etc and shifting to MES yard or any other location complete all as specified and directed.
Dismantling of ACSR/ AAC conductor of any description from HT poles complete all as specified and directed.
Dismantling earth wire or copper conductor, service feeder or distributor span complete all as specified and directed.
Dismantling cross-arms of M.S. channel or angle sections etc. complete all as specified and directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Supply and laying of factory made unreinforced pre-cast concrete cover class HVP type-1 with size 300mm x 180mm x 40mm laid in trenches for cable protection complete all as specified and directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed.
Supply and laying of HT underground cable XLPE insulated, screened with extruded semi conducting compound in combination with copper tape (0.3 KA for 1 sec) cores laid up, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 11000 volts earth grade 95 sq mm 3 core confirming to IS:7098 (Part-II) with latest amendements, laid in duct/ trench/ along pole etc including making connection complete all as specified and directed. Note : 1. The end termination joint shall be measured and paid separately under respective items.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, 11000 Volts grade complete all as specified and directed.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, 11000 Volts grade complete all as specified and directed.
S&F /laying of galvanized iron pipe of 80 mm bore dia light grade fixed to poles with clamps nuts, bolts and washers and with all GI fittings or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x 60cm x 6mm thick burried directly in ground vertically (to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected with GI earth lead wire of 4mm dia as earth conductor and protection pipe of 15 mm dia for earthing of poles and lightening arrester incl connection with the equipment. with nuts, bolts , check nuts , washers, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around, top & bottom watering pipe 20mm bore of GI medium grade with funnel and wiremesh all as shown in electrical plate No. 5 of SSR -1991 Part I and connecting to arthing test point,main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c both ways in cement concrete(1:2:4) type B-1 all asshown in electrical plate in No 5 of SSR(Pt-I)1991 complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
M&L for HT lightening arrester metal oxide type (gap less) for out door use complete with all fittings and fixing arrangements transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps,nuts, bolts ,washers and connecting to earth wire 4mm dia GI comp lete all as specified and directed with manufacturers test certificate complete all as specified and directed.
S&F air break gang operated triple pole mechnically operated mounted on HT insulators and galvanised steel frame with operating rod of 25 mm bore medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt , 50 HZ supply incl 12 insulator and drop out fuse carrier element complete all as specified and directed.
S&F cable route markers made of cast iron with embossing of HT Cable or LT Cable, supporting MS angle of 75 cm long, for HT/LT cable route marking duly embedded in and including PCC (1:3:6) foundation up to 30 cm including excavation and earth work complete all as specified and directed.
M&L for disc type insulator, poprcelain, vitreous in single disc assy for tension with tension clamps for conductors, working pressure 11000 volts of size 145 mm high and 255 mm dia ball complete all as specified and as directed.
S&F pin type porcelain vitreous white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut 150 mm height, 150 mm dia for 11000 volts grade complete all as specified and as directed.
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-55 (11 meter long) in true vertical position all as specified and directed and including the following:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 1200mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 1200mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm x 450 mm square or as directed by Engr-in-Charge complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and writting pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
S&F ACSR conductor of any size including binding on existing HT poles or new poles with 02mm dia aluminium binding wire complete all as specified and as directed.
S&F danger notice plate of 1.6mm thick, MS sheet, vitreous enamelled white, with letters, figuers and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3 mm, nuts-bolts, of approved size for HT 25 x 20 cm complete all as specified and as directed.
M& L for cutting of floor /wall/ road/ footpath for removal of HT U/G cable of any size/ description and making good the same as per existing surface after relaying the same or new cable complete all as specified and as directed.
Dismantling of insulator any type complete all as specified and as directed.
S&F of stay assembly consisting of galvanised stay wire 7/10 SWG stay bow of 14 mm dia, stay rod 16 mm dia 180 cm long with loop insulators stay plate 230 x 230 mm x 6 mm with PCC foundation 1:3:6 type C2 complete with stay clamps, bolts and nuts etc complete all as specified and directed including the following :-. (a) Excavation and earth work for stay foundation in soft/loose soil,disposal of surplus soil to a distance n exc 50 metres & depositing where directed at a level n.exc 1.5 mtr from the starting point as directed. (b) PCC 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in embedding blocks all as specified.
S&F cable twin core PVC insulated and unsheathed flat solid aluminium conductor of size 2.5 Sqmm including PVC conduits over cable with proper sadling on wall/ ground complete all as specified and directed.
S&F 4 pole Isolator, 63 Amps, 415 Volts including weather proof Box complete all as specified and directed.
S&F 45 watt LED street light fitting powder coated pressure die cast aluminium compact heat resistance toughened glass with lens including GI bracket of suitable size of length 1.5 mtr with fixing arrangement on pole including clamps nut bolt etc. complete all as specified and directed.
S&F in repair loop-in loop-out box of size 20x20x15cm made of 1.6mm thick PVC sheet weather proof, dust and vermin proof with hinged door of locking arrangements and slanting cover on top with provision of aluminium busbar of size 25 x 2mm - 2 No fixed on insulator complete fixed on pole with and including suitable size MS flat iron clamps, nuts, bolts and washers, etc. complete all as specified and directed.
S&F 100 watt LED flood light powder coated pressure die cast aluminium compact Lumos heat resistance toughened glass including fixing arrangement on wall complete all as specified and directed.
Supply and laying sub class 'B' bricks, old size, well burnt laid flat dry for protection of under ground cable complete all as specified and directed.
S&F 40mm bore dia GI pipe, light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
Supply laying and testing cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cables (heavy duty) with stranded aluminium conductor , 1100 volts grade of size 4 core 10 Sqmm complete all as specified and directed.
M&L for PCC 1:3:6 type C-2,using stone aggregate 40mm graded as in foundation of stays and coping of poles including necessary form work where required and fair finish to the exposed surfaces complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles and making of cable duct including necessary form work where required and fair finish to the exposed surfaces complete all as specified and directed.
Supply and erection, steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31 (09 mtrs long) Class -10 in truly vertical position, including two coats of synthetic enamel paint in black and white strips upto 1.5 mtr height from coping over a coat of red oxide primer including numbering of poles complete all as specified and directed.
S&F of danger notice plate of 1.6mm thick, MS sheet, vitreous enamelled white, with letters, figuers and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3 mm, nuts-bolts, of approved size for LT 20 x 15 cm complete all as specified and directed.
Supply installing testing and commissioning of AC 3 phase 50 cycle per second 400 KVA capacity transformer confirming to IS 1180 copper wound step down out door type 11000/433 volts ( at on no load) double wound oil imeressed naturally cooled with internal cooling tubes delta connected on primary ( HV) side and star connected on secondary ( LV) side in accordance with vector symbol Dy-11 ( Vector group IV) with neutral brought on secondary ( LV ) ride and having at (+/-) 2.5%, (+/-) 5% and 7.5% taping to be changed by means of hand operated “ OF LOAD” tape changing gear. The maximum temp raised should not exceed 45 degree centigrate in oil and 55 degree centrigrate in HV & LV winding when measured by the resistance method after continuous full load run and in imfident temp of 40 degree C . The transformer shall be complete with standard fitting and mainly comprising the following:- (a) One cable box on LV side ( secondary side) consist of 4 Nos porcelain bushing with studs made out of copper with nuts and washers and one cable glands suitable for reception of taking out one No 3.5 core LT cable of requested size 1100 volts grade PVC sheathed and PVC insulated armoured heavy duty. b) Conservator with drain valve and oil level indicator. (c) Dehydrating beather with first fill of dehydrating agent silica gel. (d) Explosive vent.
(e) Thermo meter pocket on tank cover (f) One No 100 mm dia dial type thermo meter vapour pressure type having range –120 degree C with more reading pointer maximum indicator and re-setting device (g) Rating plate with terminal marking (h) Two earthing terminal on tank and tank cover to facilitate fixing of 30x6 mm GI strips (j) Oil level gauge (k) Oil drain and filter valve (l) Lifting lugs/hooks (m) Oil filter hole with cap/plug with connection complete (n) Air relief valve plugs (o) Four plain solid cast steel detachable by directional rollers (p) Extra bushing ;for neutral out side the cable for providing independent earthing for neutral. (q) First filling fresh oil conforming to relevant IS and tested upto 40 KV dielectric strength
All as per srl item No. 39 here-in-before but of capacity 315 KVA.
All as per srl item No. 39 here-in-before but of capacity 250 KVA.
Supply laying & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) 1100 volt grde with standard aluminium conductor of size 240 sqmm 3.5 core complete all as specified and directed.
Labour & transportation for shifting of 11/0.433 KV transformer from one location to another location with in cantt area and making connections and testing complete all as specified and directed. Note : Safe transportation of transformer for shifting is responsibility of contractor.
Supply, installation, commissioning and testing of Voltage Stabilizer for autoamatic operation, three phase naturally oil cooled indoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuarcy (+/-) 2.5% and speed of correction 8 volts per second and capacity of 25 KVA complete all as specified and directed.
Supply, installation, commissioning and testing powder coated factory made out door type double door panel board confirming to IP 66 protaction, of suitable size made of Robust steel sheet construction made from min 2.15 mm steel sheet with countersunk holes at bottom for base mounting brackets and sheet steel gland plates for cable entry, formed gasket arround doors, with provision of Lock inserts, earthing straps, door stay and grouted in ground by using angle iron frame of size 50mm x 50mm x 6mm, pedastal type and provided with four nos of angle iron supports duly embedded in foundation using PCC (1:2:4) type C-1 with 20mm graded stone aggregate. The panel will be prewired with suitable size PVC insulated copper conductor cable, multistranded housed with the following accessories:-
M&L for earthing complete with galvanised or steel earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground vertically (to a depth not less than 2.25mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to strip 32x6 mm size with nuts, bolts, check nuts, washers, earth plate surrounded by packed layers of charcoal, dust and common salt 15 cm thick all arounf, top and bottom watering pipe 20mm bore of GI medium grade with funnel and wire mess all as shown in electrical plate No. 5 of SSR(Part-I) 1991 and connecting to earthing test point, main switch board and testing on completion including PCC chamber concrete 1:3:6 type C-2 and RCC cover 75mm thick with MS TMT bar 8mm dia @ 150mm c/c booth ways in cement concrete (1:2:4) type B-1 all as shown in electrical plate No. 05 of SSR(Part-I) 1991 complete all as specified and directed.
M/S HINA ELECTRICALS
Perfect Electricals and Engineers
Ravi Electrical
Ridhi engineers and builders
SHAHJEE FRIDGE SERVICE
Amit Engineering
Garg Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .