| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.8 LAccepted-AOC | L1 | Accepted-AOC Agreement executed | |
| 2 | L2₹51.0 L+₹20,738.43 (0.41%)Rejected-AOC | L2 | Rejected-AOC L2 Rejected | |
| 3 | L3₹51.3 L+₹56,709.33 (1.12%)Rejected-Finance | L3 | Rejected-Finance L3 Rejected | |
| 4 | L4₹51.8 L+₹1.0 L (2.02%)Rejected-Finance | L4 | Rejected-Finance L4 Rejected | |
| 5 | L5₹54.6 L+₹3.9 L (7.64%)Rejected-Finance | L5 | Rejected-Finance L5 Rejected |
Tender Value
₹61.9 L
EMD Value
₹50,000
Closing Date
20 Oct 2023, 3:00 pmClosed
Executive Engineer
PWD Building Division,Thrissur
GENERAL GED Annual Plan 2022 23 Construction of School building for Govt K V Higher Secondary School Eriyad Thrissur work General Civil Work 1
2023_PWD_610151_1
35/2023-24/EE
Open Tender
Civil Works - Buildings
Item Rate
365 days
Eriyad
Please refer Tender documents.
10 documents required · 10 mandatory
₹2,760
Yes
₹50,000
Yes
22 Nov 2023
6 Oct 2023
25 Oct 2023
6 Oct 2023
20 Oct 2023
6 Oct 2023
Amount
Detailed estimate
OD100141/2021-2022:Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. Note:- Cement content obtained as per mix design shall be used by the contractor at site to obtain the required strength.Minimum cement content to be used for this item is @ 330 kg/ cum. There is no additional payment for exess cement used in the mix design seperately as per circular no.CE/BL/GL/6541/2015 dtd.30.08.17 of CE, BLDS PWD.All work above plinth level upto floor V level
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.16.1:Centering and shuttering including strutting, etc. and removal of form for: Edges of slabs and breaks in floors and wallsUnder 20 cm wide
5.9.19:Centering and shuttering including strutting, etc. and removal of form for:Weather shade, Chajjas, corbels etc., including edges
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
15.2.2:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:4:8 leaner mix ( including equivalent design mix)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
50.13.1:9 mm cement plastering of mix : 1:3 (1 cement : 3 fine sand ) including all cost of materials, labour charges etc complete
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD100145/2021-2022: supplying and fixing of Pressed Steel windows using frame 82*60*12mm and shutters 50*20*1.20mm made out of Galavano steel sheets welded and assembled with 10mm dia MS rod at 10cm clear gap horizontaly and 25*5mm flat 2 nos per each shutter vertically as grill with SS butt hinges,hooks and eyes. stay NSD handles and fitted with 1mm thick embossed and stiffened sheet as shutter panel instead of glass panels or as specified and inclusive of labour charges for fixing all window fittings( optional items like tower bolts, handles,Aluminium beading etc.) but excluding the cost of window fittings and beadings and finally applied with suitable primer
OD100146/2021-2022:Supplying and fixing pressed steel door of standard pattern with frame as per profile of IS 4351 of section 105x60 mm using 18 G (1.2mm thick Galvano sheet) sheet and shutters made of section 75 x 30 cm for oyter styles and horizontal members and then inserted with enclosed and stiffned sheet 26 CR as per specification with zincromate primer coat measured in sequence metre totally including all charges for fixing handle, aldrop, but hinges etc. complete
13.61.1:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:Two or more coats on new work
OD25845/2023-2024:Providing and laying Vitrified tiles (double charged) indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4coarse sand) Size of Tile 600x600 mm Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.
50.18.9.16.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10Kgf/cm2 - External work - Exposed on wall
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
4.2.5:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:3:6 ( 1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size)
P K Umesh
MOHAMMED MUTHU IBRAHIM
DAVIS ANTO P
SHAMSEER AHAMED C
MEPCON Engineering and contracting
ABDUL LATHEEF P K
SAJAN P C
Bidder Name
ABDUL LATHEEF P K
K.S.SAJEEV KUMAR
DAVIS ANTO P
SHAMSEER AHAMED C
MOHAMMED MUTHU IBRAHIM
MEPCON Engineering and contracting
SAJAN P C
P K Umesh
stage.html
html • 0.06 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_911555.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .