Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹85.5 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹87.2 L+₹1.6 L (1.89%)Rejected-AOC | 2 | Rejected-AOC L2 | |
| 3 | 3₹88.6 L+₹3.0 L (3.55%)Rejected-AOC | 3 | Rejected-AOC L3 |
Tender Value
₹95.3 L
EMD Value
₹1 L
Closing Date
7 Dec 2020, 5:30 pmClosed
Executive Engineer, RWSS Division, Athagarh
O/o Executive Engineer, RWSS Division, Athagarh
Execution of Rural Piped Water Supply Scheme to village Bhusuka and Nuagarh in Debabhuin GP under Narsinghpur block with 5 years Operation and Maintenance under RWSS Division Athagarh
2020_RWSS_64115_1
RWS/ATH/18/2020-21
National Competitive Bid
Civil Works - Others
Lump-sum
270 days
NARASINGHPUR
Please refer SBD
2 documents required · 2 mandatory
₹10,000
₹1 L
Yes
25 Jan 2021
26 Nov 2020
8 Dec 2020
26 Nov 2020
7 Dec 2020
26 Nov 2020
26 Nov 2020 - 6 Dec 2020
Amount
Laying and Jointing HDPE Pipe with FHTC. Headworks and chlorination
Supplying all materials , labour , T&P , design , drawing , soil testing etc. complete in all respect for construction of RCC Roof building pump house and construction of Compound wall alongwith site Development including laying , testing and commissioning of Rising main & Distribution system pipe line such as HDPE , GI pipe lines etc. along with required fittings & specials and construction of RCC Valve chambers, public stand posts ,Functional household tap connection for each house hold , stand alone , storage tank , installation of Chlorination system , installation of submersible pump with motor in deep Tube well etc. ( Including supply of stand by pump motor , internal wiring of pump house & installation of Servo Stabilizer , as per supplied Drawing in section - 8 and detail scope of work & Technical specification , Quantity of work mentioned in section- 5 and in ( Annexure ) of village BHUSKA and NUAGARH . All materials required shall be supplied by the contractor as per terms and condition of DTCN & all dimentions are as per supplied drawings and as per direction of Engineer- in -charge. All work shall be completed in such a manner that all house hold of entire village will get required quantity of drinking water with residual head of 7.00 mtr and residual chlorine of 0.20 mg/ ltr without any leakage in the entire PWS System.
Design , Drawing , Construction , errection , testing and commissioning of 1 No 50,000 ltrs. capacity RCC Elevated storage reservoir ( Circular type with spherical dome )with 12 mt. Staging height and 20000 ltrs. capacity RCC Elevated storage reservoir ( Circular type with spherical dome )with 12 mt. Staging height as per detailed scope of work & technical specification mentioned in section- 5 and in Annexure including testing of SBC etc. complete as per direction of Engineer- in -charge.
5YEARS OPERATION AND MAIONTAINANACE:- The contractor shall maintain the PWS Project for five ( 5 ) calender years from the actual date of completion of the project in such a manner that all the house hold of the PWS Scheme covered area will get ( adepuate ) required quantity of supply water taking supply hour as 8 hour / day without facing any problems. The contractor shallrepair and replace any types of defect arise within 24 Hrs of receipt of complain either from public or from Department. The contractor shall maintain all structure of the PWS Schemes as per terms and conditions of DTCN & Technical spacification mentioned in section - 5 and in Annexure.
SATYA SUNDAR PARIDA
SATRUJIT SAMARENDRA KUMAR PUHAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .