Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical JINDAL ITF CENTRE 28 SHIVAJI MARG MOTI NAGAR NEW DELHI 110015 INDIA | NEW DELHI | WEST DELHI | DELHI | 110015 | Accepted-Technical Technically Responsive |
| 2 | Accepted-Technical 12 106 LAXMINAGAR GOPALAPATNAM GOPALAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | Accepted-Technical Technically Responsive |
| 3 | Accepted-Technical ELECTRICAL DIVISION 8TH FLOOR NCC HOUSE MADHAPUR HYDERABAD 500081 | HYDERABAD | HYDERABAD | TELANGANA | 500081 | Accepted-Technical Technically Responsive |
Tender Value
Refer Docs
EMD Value
₹6.1 Cr
Closing Date
23 Oct 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer PH, Ananthapuramu
O/o, Superintending Engineer, Public Health Circle, Reservoir Compound, Court Road, Ananthapuramu - 515001, Andhra Pradesh, India.
Execution of Water Supply Improvement Schemes including completion of the balance stage component works in 6 ULBs and 5 MLD STP in Madakasira ULB including Operation and Maintenance for 7 years including DLP of 2 years under PH Circle,Ananthapuramu
2025_MAUD_876584_1
07/DB/AEE/1336/AIIB/WSIS/2025
Open Tender
Civil Works - Water Works
Item Rate
730 days
Ananthapuramu
Please refer Tender Document
2 documents required · 2 mandatory
₹0
₹6.1 Cr
ENC PH, Tadepalli, Guntur
12 Dec 2025
13 Sept 2025
27 Oct 2025
13 Sept 2025
23 Oct 2025
13 Sept 2025
13 Sept 2025 - 18 Sept 2025
19 Sept 2025
KALYANADURGAM MUNICIPALITY
Construction of 10 m dia Intake well cum Pump House in Penna Ahobilam Balancing Reservoir, approach bridge of 55 mts length from Intake Well Cum Pump House to Reservoir Bund with including formation of 80 mts length coffer dam.
Bailing out water with oil driven pumpsets, including hire charges, fuel charges for driver & helper all labor charges and incidental charges and as per Technical Specification
Excavation and removal of silt or silt mixed with sand in slussy condition of copper dam from reservoir bed including disposing off the same in spoil bank as directed etc., complete with intial lead 3 Km and lift of all materials to be complte with machinery and including all labour charges and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40mm graded metal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand : 8 Coarse aggregate) including cost and conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., completeas per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Raft Slab
Side Walls - 600mm Thick
Sidewalls of intake well from 400.000 mts to 397 ( Below GL )
Sidewalls of intake well from 397.000 mts to 396 ( Below GL )
Sidewalls of intake well from 396.000 mts to 395 ( Below GL )
Sidewalls of intake well from 400.000 mts to 403.000 ( Above GL)
Sidewalls of intake well from 403.000 mts to 404.000
Sidewalls of intake well from 404.000 mts to 405.000
Sidewalls of intake well from 405.000 mts to 406.000
Sidewalls of intake well from 406.000 mts to 407.000
Sidewalls of intake well from 407.000 mts to 408.000
Sidewalls of intake well from 408.000 mts to 409.000
Sidewalls of intake well from 409.000 mts to 410.000
Sidewalls of intake well from 410.000 mts to 411.000
Sidewalls of intake well from 411.000 mts to 412.000
Sidewalls of intake well from 412.000 mts to 413.000
Sidewalls of intake well from 413.000 mts to 414.000
Sidewalls of intake well from 414.000 mts to 415.000
Sidewalls of intake well from 415.000 mts to 416.000
Sidewalls of intake well from 416.000 mts to 417.000
Sidewalls of intake well from 417.000 mts to 418.000
Sidewalls of intake well from 418.000 mts to 419.000
Sidewalls of intake well from 419.000 mts to 420.000
Sidewalls of intake well from 420.000 mts to 421.000
Side Walls - 400mm Thick
Sidewalls of intake well from 421.000 mts to 422.000
Sidewalls of intake well from 422.000 mts to 423.000
Sidewalls of intake well from 423.000 mts to 424.000
Sidewalls of intake well from 424.000 mts to 425.000
Sidewalls of intake well from 425.000 mts to 426.000
Sidewalls of intake well from 426.000 mts to 427.000
Sidewalls of intake well from 427.000 mts to 428.000
Sidewalls of intake well from 428.000 mts to 429.000
Sidewalls of intake well from 429.000 mts to 430.000
Sidewalls of intake well from 430.000 mts to 431.000
Sidewalls of intake well from 431.000 mts to 432.000
Sidewalls of intake well from 432.000 mts to 433.000
Sidewalls of intake well from 433.000 mts to 434.000
Sidewalls of intake well from 434.000 mts to 435.000
Sidewalls of intake well from 435.000 mts to 436.000
Sidewalls of intake well from 436.000 mts to 437.000
Sidewalls of intake well from 437.000 mts to 438.000
Sidewalls of intake well from 438.000 mts to 439.000
Sidewalls of intake well from 439.000 mts to 440.000
Sidewalls of intake well from 440.000 mts to 441.000
Sidewalls of intake well from 441.000 mts to 442.000
Sidewalls of intake well from 442.000 mts to 443.000
Sidewalls of intake well from 443.000 mts to 444.000
Sidewalls of intake well from 444.000 mts to 445.000
Sidewalls of intake well from 445.000 mts to 445.600
lintel Beams over Rooling Shutter
sunshades with lintel beam
Ring beam at support of crane at 450 mts
Roof Beams
Floor Slab (400 mm thick) at level +446 mts
Walkway
Roof Slab 150 thick at Level :454
Motor Support Beams
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including Cost and Conveyance as per Technical specification
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Pump House Side Walls
Providing plastering in 20mm thick cement mortar 1:3 proportion with minimum 2% of approved quality water proof compound, including scaffolding, racking out joints 25mm deep, smooth finishing, curing etc. with all lead and lifts for all materials etc. complete for finished item of work and as per Technical Specification
Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical Specification for ceiling
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as per Technical Specification-walls
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete and as per Technical Specification-slabs
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work and as per Technical Specification
Supply of CI Sluice Gate(1.8x1.8m) including all mechanical arrangements such as gearing arrangements, MS extended rods with wheel arrangements for smooth lifting & lowering and fixing at different levels as directed by Engineer-in-charge and as per Technical Specification
Supply, Delivery and fabrication of Stain Steel Railing for Pump maintenance and Aluminium ladder from base slab to floor slab with each flight of 12 steps of 0.3 mt Traed and 0.15 mt rise with 25X25X5 mm angle frameance and 2 intermediate support, 5 nos of 25X5 mm Flat for foot resting. 100X50 mm 'c' Channel supports for steps on both edges. Landing flatform of 1.90X1.00 mt with 2 nos of 150X75 mm 'C' Channel supports embeded into the intake well side wall and 25X25X5 mm angular frame and 4 nos of intermediate supports, 3 mm thick MS sheet landing flatform. Hand railing with 38mm MS pipe for both flight and landing with 7 Nos of 25X25X5 mm verticals including cost and conveyance of necessary MS angles, C channels, Flats and Pipes etc., with fabrication and installation at site work with all incidental and labour charges as directed by the Engineer incharge of the work.
Supply of Stainless Steel Tubes and Pipes grade 304 handrailing upto 1.2 m Height with top railing of 40 mm dia and middle 25 mm dia and verticles with 40 mm dia including cost and conveyance of all materials, machinery, all labour charges , machine mixing, vibration, curingand all incidental & operational charges etc. complete including cost and coveyance and all labor charges and as per Technical Specification
Approach bridge
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40mm graded metal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand : 8 Coarse aggregate) including cost and conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., completeas per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Beams
Column
Walkway Slab (200 mm thick)-(@ +215 mts level)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Building Electrification and yard Lighting
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT ELEC 5.1.12
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Providing Raw Water Pumping system at PABR Reservoir by supply, delivery and erection of VT pump set with specifications of Head range of 117 mtrs, discharge of 429 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer including Supply, delivery and erection of VFD Control Panels for Pump sets all taxes but excluding GST.
Providing Raw Water Pumping system at DR KS PBR Reservoir by supply, delivery and erection of VT pump set with specifications of Head range of 117 mtrs, discharge of 429 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity
Rubber Mat 6" x 4"
Fire Buckets with stand and three buckets
Rubber Hand Gloves
Danger Board Plates
First aid kit with chart
Shock Treatment Chart
Portable rechargeble torch light
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Supply, delivery and laying of 450mm dia DI K9 Pumping Main from Intake well in PABR to intrmediate sump at Ankampalli
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of 450mm dia centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (450mm dia)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including cost of rubber gaskets and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -450mm
Supply and delivery of D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge including all taxes except GST.
200DN PN 2.5 (scour valves)
100DN PN 2.5 (isolated sluice valve for air valve)
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80DN PN2.5 Mpa( Air Valve)
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
250DN PN.2.5 ( Scour valve)
80DN PN.2.5( Isolated sluice valve for Air valve)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80 DN PN.2.5 ( Air Valve)
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m for sluice valves
200 mm Ø DI D/F Pipe of 1.00 m for scour valves
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m
200 mm Ø DI D/F Pipe of 1.00 m
Laying RCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification-Thrust Block
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450mm dia (Size 2.20*2.20*1.90 Mts)
80mm (Size 2.10*1.90*1.75 Mts)
250mm (Size 2.00*2.00*1.70 Mts)
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification- for thrust blocks
Laying RCC M-20 grade Nominal mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification -for encasing 1000 mm dia MS pipes for road and canal crossings
Road crossing by adopting trenchless technology tunneling work through specialized pipejacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but excluding cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in –charge-800 mm pipe
Supply and delivery of M.S Spirally Welded Pipes conforming to IS: 3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar (1:3) 30mm thick by short crating or gunetting duly providing wire mesh of size 50x50x3mm including cost of all materials, labor charges, transportation and including all taxes but excluding GST.-800mm MS Pipe - 10 mm thk
Construction of 250 KL Raw water Intermediate sump at Ankampalli Village.
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Raft Foundation
Sidewalls of Sump 250mm th
Columns
Ring Beams
Roof slab 125mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply & Erection of M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint, labor charges etc compelte for finished item of work ass per the Technical Specification
Construction of 7.5mx 12 m Raw water pump house at Ankampalli Village
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40mm graded metal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand :8 Coarse aggregate) including cost and conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete as per Technical Specification
Laying insitu VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification-Flooring and Ramp
Laying insitu VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
lintel beam
Roof Beams
Roof slab - 150 Thk
Sunshades 0.60m wide, 0.075m at fixed end and 0.05m at free end
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Ground floor
Parapet wall
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Ground floor
Parapet wall
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification-Walls
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and fixing of precast RCC Jollys 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification
Building Electrification and yard Lighting
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT ELEC 5.1.12
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Supply, delivery and erection of HSC pump set with specifications of Head range of 117 mtrs, discharge of 429 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor including Supply, delivery and erection of VFD Control Panels for Pump sets all taxes but excluding GST. etc., complete
Supply, delivery and erection of HSC pump set with specifications of Head range of 117 mtrs, discharge of 429 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity
Rubber Mat 6" x 4"
Fire Buckets with stand and three buckets
Rubber Hand Gloves
Danger Board Plates
First aid kit with chart
Shock Treatment Chart
Portable rechargeble torch light
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Supply, delivery and laying of 450mm dia DI K9 Raw water Pumping Main from Intermediate Sump at Ankampalli to WTP at Akkammakonda in Kalayanadurgam
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open CC road surface including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of 450mm dia centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification-450mm
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including cost of rubber gasket and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -450mm
Supply and delivery of D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
200DN PN 2.5 (scour valves)
80DN PN 2.5 (isolated sluice valve for air valve)
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80 DN PN.2.5( Air Valve)
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
200DN PN.2.5 ( Scour valve)
80DN PN.2.5( Isolated sluice valve for Air valve)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80 DN PN.2.5 ( Air Valve)
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m for sluice valves
200 mm Ø DI D/F Pipe of 1.00 m for scour valves
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m
200 mm Ø DI D/F Pipe of 1.00 m
Laying RCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification-Thrust Block
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450mm dia (Size 2.20*2.20*1.90 Mts)
80mm (Size 2.10*1.90*1.75 Mts)
250mm (Size 2.00*2.00*1.70 Mts)
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Laying PCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification -for encasing 800 mm dia MS pipes for road and canal crossings
Road crossing by adopting trenchless technology tunneling work through specialized pipejacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but excluding cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in –charge-800 mm pipe
Supply and delivery of M.S Spirally Welded Pipes conforming to IS: 3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar (1:3) 30mm thick by short crating or gunetting duly providing wire mesh of size 50x50x3mm including cost of all materials, labor charges, transportation and including all taxes but excluding GST.-800mm dia 10mm Thk
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.-for road restoration
Design and Construction of 10.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PH SSR 2025-26 .All valves in the Filtration Plant should be compatable for operation with motorised Actuators integrated to SCADA
Construction of Recycling of Back Wash Water unit at WTP
Construction of 100 KL Collecting Sump at Wtp
Earthwork in excavation for structures as per drawing and technical specifications Cncluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Sidewalls of Sump 250mm th
Columns
Ring Beams
Roof slab 125mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply and fixing of M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint etc compelte for finished item of work and as per Technical Specification
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge -150 mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification-150mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -150mm dia
CONSTRUCTION OF 200 KL CAPACITY SETTILING TANK AT WTP
Earthwork in excavation for structures as per drawing and technical specifications Cncluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Sidewalls of Sump 250mm thk
Columns
Ring Beams
Roof slab 125 mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply and fixing of M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint etc compelte for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete for finished item of work as per Technical Specification
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge -150 mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification-150 mm dia
Jointing D.I. pipes and fittings and valves with flanged ends but including cost of materials and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -150 mm dia
Laying of 200 mm dia DI K-9 Pumping Main from Water settlement Tank to Aerator ( 100 m) and Sludge ponds ( 50 m)
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
200 mm dia.pumping Main DI K9
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
200 mm dia.pumping Main DI K9
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including cost of rubber gaskets and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
200 mm dia.pumping Main DI K9
Provision for 4 No 6 Kw Pumpsets Pump back wash water from sump to Aerator
Supply ,delivery,and erection of 4 Nos of Centrifugal pumpsets of 6 KW capacity Centrifugal pump sets having discharge of 9 lps againt head of 16 mts with combined efficiency of 60% to pump Back Wash Water from Sump to 10.0MLD WTP with 100% stand by of standard make including suction, and delivery connections , Panel boards, cables, earthing arrangements, Non return valves, Butter fly valves , Providing thrust blocks, M.S specials and pipes connection upto puming main, , all taxes and duties, and all labour charges etc., complete including delivery connections upto pumping main.
SLUDGE PONDS
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in hard Rock blasting prohibited for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -Mechanical
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
a)Floor Slab
Base slab
b)Sidewalls of Sump
Outer wall
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Plastering with CM (1:3) 20 mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical specification.
Construction of 250 KL clear water sump at 10.0MLD WTP.
Earthwork in excavation for structures as per drawing and technical specifications Cncluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Sidewalls of Sump 250mm thk
Columns
Ring Beams
Roof slab 200mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply & Erection of M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint, labor charges etc compelte for finished item of work ass per the Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete for finished item of work and as per Technical Specification
Supply and fixing of M.D 10 500 mm dia SFRC manhole covers and frames with ISI marking as per BIS 12592 (Part - 1&2) including cost and coveyance and all labour charges and as per Technical Specification
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
300 mm dia sluicccw valves
2000mm dia scour valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
300 mm dia sluicccw valves
200mm dia scour valves
Jointing D.I. pipes and fittings with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
300 mm diaflanged joints
200 mm diaflanged joints
Construction of 250 KL GLBR on Akkamma Konda Hillock
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Sidewalls of Sump250 mm thick
Columns
Ring Beams
Roof slab 200mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply & Erection of M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint, labor charges etc compelte for finished item of work ass per the Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete for finished item of work and as per Technical Specification
Supply and fixing of M.D 10 500 mm dia SFRC manhole covers and frames with ISI marking as per BIS 12592 (Part - 1&2) including cost and coveyance and all labour charges and as per Technical Specification
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
350 mm dia sluice valves
150 mm dia scour valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
350 mm dia sluice valves
150mm dia scour valves
Jointing D.I. pipes and fittings flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
350 mm diaflanged joints
150 mm diaflanged joints
Construction of 7.5mx 12 m Clear water pump house at Head water Works
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40mm graded metal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 4 Sand :8 Coarse aggregate) including cost and conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mmm/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification-flooring and ramps
Laying VRCC M-25 grade design mix using 20 mmm/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab - 150 mm
Sunshades 0.60m wide, 0.075m at fixed end and 0.05m at free end
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Ground floor
Parapet wall
Plastering with CM (1:3), 20mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification-inside and outside
Ground floor
Parapet wall
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Plastering with CM (1:3), 20mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours). The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities.- Walls
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and fixing of precast RCC Jollys 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification
Building Electrification and yard Lighting
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT ELEC 5.1.12
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Supply, delivery and erection of HSC pump set with specifications of Head range of 49 mtrs, discharge of 216 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor including Supply, delivery and erection of VFD Control Panels for Pump sets all taxes but excluding GST. etc., complete
Supply, delivery and erection of HSC pump set with specifications of Head range of 49 mtrs, discharge of 216 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity
Rubber Mat 6" x 4"
Fire Buckets with stand and three buckets
Rubber Hand Gloves
Danger Board Plates
First aid kit with chart
Shock Treatment Chart
Portable rechargeble torch light
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Supply, delivery and laying of 450 mm dia DI K9 pumping Main from Sump at Head Works 250 KL GLBR on Hillock
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of 450mm dia centrifugally cast (spun) Ductile Iron x K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification-450mm
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including cost off rubber gaskets and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -450mm
Supply and delivery of D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and coveyance ans stacking as per standards and as directed by the Engineer-in-Charge
200DN PN 1.6 (scour valves)
100DN PN 1.6 (isolated sluice valve for air valve)
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 DN PN.1.6( Air Valve)
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
200DN PN 1.6 ( Scour valve)
100DN PN 1.6( Isolated sluice valve for Air valve)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
100 DN PN.1.6 ( Air Valve)
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m for sluice valves
200 mm Ø DI D/F Pipe of 1.00 m for scour valves
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
450 mm Ø DI D/F Pipe of 1.00 m
200 mm Ø DI D/F Pipe of 1.00 m
Laying RCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification-Thrust Block
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450mm dia (Size 2.20*2.20*1.90 Mts)
100mm (Size 2.10*1.70*1.85 Mts)
200mm (Size 2.00*2.00*1.70 Mts)
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Supply, delivery, laying, jointing and testing of DI class K7 Gravity main 450mm/400mm/350mm/ 300mm/250mm/200mm/150 mm dia from Sump at Head Works to various ELSRS in Zone-I, Zone-II, Zone-III , Zone-IV, and Zone-VI
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
450mm dia.
400mm dia.
300mm dia.
200mm dia.
150mm dia.
100 mm dia.
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
450mm dia.
400mm dia.
300mm dia.
200mm dia.
150mm dia.
100 mm dia.
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including rubber gaskets, all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450mm dia.
400mm dia.
300mm dia.
200mm dia.
150mm dia.
100 mm dia.
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per Technical specification
For Sluice valve of 400mm dia - PN1.6
For Sluice valve of 150mm dia - PN1.6
For Scour valve of 150mm dia - PN1.6
Supply and delivery of PN 1.6 Mpa D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Sluice valve of 400mm dia - PN1.6
Sluice valve of 300mm dia - PN1.6
Sluice valve of 200mm dia - PN1.6
Sluice valve of 150mm dia - PN1.6
Sluice valve of 150mm dia - PN1.6 for scour
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia. PN 1.6
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
400mm dia
300mm dia
200 mm dia
150 mm dia
150mm dia
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-100mm dia. PN 1.6
Laying RCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification-Thrust Block
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.- for road restoration
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
400mm dia (Size 2.20*2.20*1.90 Mts)
300mm dia (Size 2.10*2.10*1.80 Mts)
200mm dia (Size 2.00*2.00*1.70 Mts)
150mm dia (Size 1.80*1.80*1.50 Mts)
150mm dia (Size 1.80*1.80*1.50 Mts)
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Construction & Completion of balance works of 600 KL Capacity M30 Grade desing mix VRCC ELSR 21.0Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-I. The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 700 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-II. The present Stage of Work is appended in the Tender Document
Design and Construction of 500 KL Capacity M30 Grade desing mix VRCC ELSR 12Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-III.
Construction & Completion of balance works of 900 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-IV. The present Stage of Work is appended in the Tender Document
Design and Construction of 300 KL Capacity M30 Grade desing mix VRCC ELSR 17Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-V. The present Stage of Work is appended in the Tender Document
Inlet ,outlet Arrangments with DI fittings and valve pits for 300 KL capacity ELSR at Mudigallu
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
150mm dia Sluice Valves (PN - 1.6)
150mm dia Scour Valves (PN - 1.6)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
150mm dia (Size 1.80*1.80*1.50 Mts)
150mm dia (Size 1.80*1.80*1.50 Mts)
Design and Construction of 300 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Zone-VI
Inlet ,outlet Arrangments with DI fittings and valve pits for 300 KL capacity ELSR at Ontimidde
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
150mm dia Sluice Valves (PN - 1.6)
150mm dia Scour Valves (PN - 1.6)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
150mm dia (Size 1.80*1.80*1.50 Mts)
150mm dia (Size 1.80*1.80*1.50 Mts)
Errection of 315 KVA transformer with Transformer yard 15.00 X 12.00m near near raw water intake well in PABR
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - by mechanical means
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by Engineer-in-Charge
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work as per technical specification for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Errection of 500 KVA transformer with Transformer yard 15.00 X 12.00m near Intermediate sump at Ankampalli
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04046e 500KVA
1. Quantity : 1
2. Rated KVA : 500 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- by manual means
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
LayingVRCC M-20 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
column footings
columns
plinth beam
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by Engineer-in-Charge
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Errection of 315 KVA transformer with Transformer yard 15.00 X 12.00m near Head Works
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04046e 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - by manual means
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by Engineer-in-Charge
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Intake Well Cum Pump House at PABR-Watchman quarters
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification Up to 3.00 Mts depth below GL in ordinary soils With Mechanical Means.
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Excavation for structures in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification -mechanical means
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 155 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification Ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work.windows 1.50x1.20
Providing PCC M-10 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per Technical Specification.For flooring
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent as per Technical Specification
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- Manual Means.
Collection, Supply and filling of sand from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per technical specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) with 2nd class Bricks including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification out side & inside
Laying VRCC M-25 grade Nominal mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Intermediate Sump @Ankampalli-Watchman quarters
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification Up to 3.00 Mts depth below GL in ordinary soils With Mechanical Means.
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Excavation for structures in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Hard rock (blasting prohibited)
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 155 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification Ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities and as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work.windows 1.50x1.20
Providing PCC M-10using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per Technical Specification
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent as per technical Specification
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification-ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Collection, Supply and filling of sand to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. as per technical specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification out side & inside
Laying VRCC M-25 grade Nominal mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Head Works -Watchman quarters
Earthwork in excavation for structures as per drawing and technical specification including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification With Mechanical Means.-ordinary soil
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Excavation for structures in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 155 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification Ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities and as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical Specification .windows 1.50x1.20
Providing PCC (1:3:6) using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks etc complete as per Technical Specification
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent as per technical Specification
Supply and Fixing of GI union Ist Quality etc complete as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification-ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete and as per Technical Specification out side & inside
Laying VRCC M-25 Nominal design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
300 KL ELSR at zone v Watchman quarters
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical SpecificationUp to 3.00 Mts depth below GL in ordinary soils With Mechanical Means.
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Excavation for structures in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause Hard rock (blasting prohibited)
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 155 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification Ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities and as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical Specification .windows 1.50x1.20
Providing PCC (1:3:6) using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent as per technical Specification
Supply and Fixing of GI union Ist Quality etc complete as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete and as per Technical Specification out side & inside
Laying VRCC M-25 grade Nominal mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
300 KL ELSR at zone vi-Watchman quarters
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical SpecificationUp to 3.00 Mts depth below GL in ordinary soils With Mechanical Means.
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Excavation for structures in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause Hard rock (blasting prohibited)
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 155 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification Ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities and as per Technical Specification(in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical Specification .windows 1.50x1.20
Providing PCC (1:3:6) using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent as per technical Specification
Supply and Fixing of GI union Ist Quality etc complete as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick work in CM 1:5 mix using 2nd class bricks brought from approved kilns including cost and conveyance of all materials and all labour charges ,curing for 21 days etc complete and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete and as per Technical Specification out side & inside
Laying VRCC M-25 grade Nominal mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing Protection Compound Wall for Head Water Works at Akkamma Konda and Sump @Ramapuram
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Columns Footing
Columns
Plinthbeams
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete and as per Technical Specification
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities.
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Supply,delivery and fixing of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat as per approved design by the department including cost and coveyance and all labour charges for fixing for finihsed item of work and as per Technical Specification
Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per Technical Specification
Supply and Fixing of Name Boards with MS chanels and angulars with GI sheet as per Technical Specification
Levelling of WTP Site ,ELSR Sites Providing Approach Road from Main road to Glbr and Internal Roads in Head Works at Akkamma Konda
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification mechnical means
Earthwork in excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification and as per Specification drawings and as directed by the departmental Officer including all Incidental and operational Charges etc Complete Leveling of ELSR Sites
Excavation for structures in hard rock (blasting ) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause Hard rock (blasting prohibited)-Approach Road to GLBR
Supply and spreading of Crusher dust including watering, tamping including cost and conveyance of all materials and labour charges etc complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations by Mechanical Means
Drains
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete and as per Technical Specification
Drains
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Drains
Laying VCC M-20 grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Drains
Laying RCC M-20 grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Culverts
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Culverts
Instrumantation and Automation of the Pumping System
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station-1 as per the above specification
For Raw Water Pumping Station-2 as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station-1 as per the above specification
For Raw Water Pumping Station-2 as per the above specification
For Clear Water Pumping Station as per the above specification
For 250KL GlBR as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Raw Water Pumping Station-2 as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 250 - PN 16 pump control valve for Raw Water Pumping Station-1 as per the above specification
DN 250 - PN 16 pump control valve for Raw Water Pumping Station-2 as per the above specification
DN 200 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
400MM Dia Above Specification.
outlet of Clear Water Pumping Station at Akkamma Konda
Outlet of 250KL Clear Water sump
450MM Dia Above Specification.
outlet of Raw Water Pumping Station-1 at DR KS PBR Reservior
Inlet of Raw Water Sump at Rama Sagaram
outlet of Raw Water Pumping Station-2 at Rama Sagaram
Inlet of Raw Water main at WTP at Akkamma Konda
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Outlet-1 of Water Treatment plant
Raw Water Outlet-2 of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Outlet-1 of Water Treatment plant
Raw Water Outlet-2 of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Outlet-1 of Water Treatment plant
Raw Water Outlet-2 of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Outlet-1 of Water Treatment plant
Raw Water Outlet-2 of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at WTP
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water Outlet-1 of Water Treatment plant
Raw Water Outlet-2 of Water Treatment plant
Clear Water outlet of Water Treatment plant
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department
Reservoir Inlet Management
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
100MM Dia Above Specification.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
150MM Dia Above Specification.
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
200MM Dia Above Specification.
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
150MM Dia Above Specification.
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
200MM Dia Above Specification.
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
100MM Dia Above Specification.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
150MM Dia Above Specification.
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
200MM Dia Above Specification.
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
150MM Dia Above Specification.
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
200MM Dia Above Specification.
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhencive over temprature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 300 KL Zone-V ELSR at Mudigallu
Inlet of 300 KL Zone-VI ELSR at Ontimmide
Inlet of 700 KL Zone-I ELSR at NTR colony
Inlet of 600 KL Zone-II ELSR at Gravy yard
Inlet of 500 KL Zone-III ELSR at Dhobhi Ghat
Inlet of 900 KL Zone-IV ELSR at Marempalli
24 x 7 Water Supply :: DMA Management
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
200MM Dia Above Specification.
Inlet of DMA-1&3 under 900 KL ELSR at Marampalli
250MM Dia Above Specification.
Inlet of DMA-2 under 900 KL ELSR at Marampalli
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1&3 under 900 KL ELSR at Marampalli
250MM Dia Above Specification.
Inlet of DMA-2 under 900 KL ELSR at Marampalli
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
200MM Dia Above Specification.
Inlet of DMA-1&3 under 900 KL ELSR at Marampalli
250MM Dia Above Specification.
Inlet of DMA-2 under 900 KL ELSR at Marampalli
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1&3 under 900 KL ELSR at Marampalli
250MM Dia Above Specification.
Inlet of DMA-2 under 900 KL ELSR at Marampalli
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Under 600 KL ELSR at NTR Colony
Under 700 KL ELSR at Graveyard
Under 500 KL ELSR at Dhobi Ghat
Under 300 KL ELSR at Mudigallu
Under 300 KL ELSR at Ontimidde
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 900 KL ELSR at Marampalli
Construction of SCADA Control Room at Filtration Plant Site
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Laying Plain Cement concrete (M 30) Design Mix using 20mm m/c HBG metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete as per technical specification for Bed.Septic Tank
Laying Plain Cement concrete (M 30) Design Mix using 20mm m/c HBG metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete as per technical specification for walls.Septic tank
Laying insitu VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification-Outside
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification-Inside
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specificationfor ceiling
Flooring with Non skid ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials and as per Technical Specification for Floor
Flooring with Non skid ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials and as per Technical Specification for Toilets
Providing skirting to internal walls to 15 cm height/risers of steps with ceramic tiles 7.30 mm thick length equal to flooring stones, set over base coat of CM (1:3) 12 mm thick with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointed with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc., complete including seigniorage charges, etc., complete for finished item of work, but excluding the cost of conveyance of all materials and as per Technical Specification
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities.- Walls
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as directed by the departmental authorities and as per Technical Specification.- insidel Walls
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification internal
Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work as per Technical Specification for Single leaf Door
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per Technical Specification Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Supply of 1.5 TR 3 Star capable of delivering 18000 BTU/ hr and above with operating on refrigerant R-32 / R-410A AC unit Makes: As per list of recommended brands as category INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz,1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser 1.5 TR, 5 Star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R- 410A. Makes: As per list of recommended brands as category I. ELEC-5.5.1 Aa
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 27.25 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-I.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -Mechanical means
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Hard rock and boulders more than 3 Cum in size for pipeline trenches without blasting for pipeline trenches etc., and as per specification drawing and as directed by departmental officers and to protecting the existing walls and other structures etc., so as not to disturb the existing utility services existing water supply lines, sewers, telephone,power cables/ducts, storm water drains, traffic signals ,etc., during the laying of pipe line taking all precautionary measures in the restricted areas with the initial lead of 50mts and intial lift of 3m for pipeline trenches for laying of water main taking all precautionary measures in the restricted areas such as urban areas including divertion of traffic including all incidental and operational charges etc., complete as per Technical Specification
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
200mm dia HDPE PE-100 gr pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
200mm dia HDPE PE-100 gr pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materialsas per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
315mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
BENDS
315mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand from approved quarry including cost and conveyance, watering, tamping including all labour charges etc complete for finished item of work and as per the Technical Specification.
Supply and delivery of PN1.6D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
400mm dia valve
300mm dia sluice valve
150mm dia sluice valve
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
400mm dia valve
300mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
400 mm DF pipes 1.00 m long
300 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing D.I. pipes and fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification-for drain crossing
400mm dia valve
300mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation, taxes etc. complete.
400 mm DF pipes 2.00 m long
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing D.I. pipes and fittings with rand valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
400 mm DF pipes 2.00 m long
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
400mm [2.20*2.20*1.90 Mts]
300mm [2.10*2.10*1.80 Mts]
150mm [1.80*1.80*1.50 Mts]
100mm [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 25.96 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-II.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160mm dia HDPE Pipe
110mm dia HDPE Pipe
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
250mm dia HDPE Pipe
160mm dia HDPE Pipe
110mm dia HDPE Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials and as per the Technical Specification.
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST.and as per the Technical Specification.
200mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
BENDS
200mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery PN 1.6 Mpa D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and coveyance ans stacking as per standards and as directed by the Engineer-in-Charge
400mm dia valve
300mm dia sluice valve
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
400mm dia valve
300mm dia sluice valve
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
400 mm DF pipes 1.00 m long
300 mm DF pipes 1.00 m long
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
400mm dia valve
300mm dia sluice valve
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
400mm dia valve [2.20*2.20*1.90 Mts]
300mm dia sluice valve [2.10*2.10*1.80 Mts]
250mm dia valve [2.00*2.00*1.70 Mts]
200mm dia sluice valve [2.00*2.00*1.70 Mts]
150mm dia sluice valve [1.80*1.80*1.50 Mts]
100mm dia sluice valve [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 13.66 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-III.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and Delivery of HDPE Pipes of pressure 6Kgs/ Sqcm and 100 grade confirming to IS: 4984 - 1995 including transporation to any where in AP.excise duty, sales tax and excluding specials etc complete as per standard specifications
OD 110mm x 125mm
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
250mm dia HDPE PE-100 gr pipe
200mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
250mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
BENDS
250mm dia PN 12.50 PVC-O Pipes
315mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
400 mm DF pipes 2.00 m long
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
400 mm DF pipes 2.00 m long
300 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
250mm dia valve [2.00*2.00*1.70 Mts]
200mm dia sluice valve [2.00*2.00*1.70 Mts]
150mm dia sluice valve [1.80*1.80*1.50 Mts]
100mm dia sluice valve [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 20.19 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-IV.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160mm dia HDPE Pipe
110mm dia HDPE Pipe
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
200mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
200mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
BENDS
200mm dia PN 12.50 PVC-O Pipes
250mm dia PN 12.50 PVC-O Pipes
400 mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge including all duties except GST.
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
400 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
400 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 8.379 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-V
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160mm dia HDPE Pipe
110mm dia HDPE Pipe
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST.
400 mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Laying and jointing of HDPE pipes by butt fusion welding as per IS 7634 - part - II / 1975 as amended from from time to time to the aligment and gradient and testing the pipe line to the required pressure.
250mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per BIS No. 7634 - Part III - 1975.
400 mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
400 mm dia PN 12.50 PVC-O Pipes
BENDS
400 mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification Quantity equal to rock quantity
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge including all duties except GST.
200mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
400 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
400 mm DF pipes 2.00 m long
250 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
250mm dia valve [2.00*2.00*1.70 Mts]
200mm dia sluice valve [2.00*2.00*1.70 Mts]
150mm dia sluice valve [1.80*1.80*1.50 Mts]
100mm dia sluice valve [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 9.03 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-VI.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Earthwork excavation by Manually in all types of soils for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160mm dia HDPE Pipe
110mm dia HDPE Pipe
Supply, & delivery of PN 12.50 PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS 16647:2017 inclusive cost of EPDM gasket seals on joints, and transportation anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
250 mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
250mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
110mm dia HDPE PE-100 gr Pipe
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical specification.
250 mm dia PN 12.50 PVC-O Pipes
200mm dia PN 12.50 PVC-O Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery at site of moulded or fabricated OPVC fittings compatible with OPVC pipes confirming to IS 16647-2017 to anywhere in Andhra Pradesh, excluding GST and as per the Technical Specification.
250 mm dia PN 12.50 PVC-O Pipes
BENDS
250 mm dia PN 12.50 PVC-O Pipes
REDUCERS
160 OD to 200 OD Pipes
250 MM x 200 MM
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge including all duties except GST.
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
100mm dia sluice valve
100mm dia sluice valve for scour
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
100 mm DF pipes 1.00 m long
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
250 mm DF pipes 2.00 m long
200 mm DF pipes 2.00 m long
150 mm DF pipes 2.00 m long
100 mm DF pipes 2.00 m long
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab
250mm dia valve [2.00*2.00*1.70 Mts]
200mm dia sluice valve [2.00*2.00*1.70 Mts]
150mm dia sluice valve [1.80*1.80*1.50 Mts]
100mm dia sluice valve [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work - Road Formation
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.for Road Formation
Providing 15mm dia (6881 Nos) new House service connections & 5000 nos House service connections
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
for New connections
Connection at House Side
Connection at Opposite Side
With CC&BT Road Cutting for Pits
in Earthen Roads
HH-side in Earthen Roads
Opposite Side in Earthen Roads
OPPOSITE SIDE IN CC &BT ROADS
AMR Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
for domestic Water Meters as per above specification for all reservoirs comman area
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Nos
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Nos
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider -1 Nos
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete 1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer - 1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station at Kalyandurgam municipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Kalyandurgam municipality with the above specifications.
Provision for Environmental Management Plan during execcution period
Monitoring Costs : Construction Phase (Two years)
Air Quality Monitoring once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs& Pipe line.
Noise level once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs& Pipe line..
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs 7 Pipe line .
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5) with Tree Gaurds as per the Technical Specification
Sprinkling of water once in a day for two years (excluding rainy days): 500 days @ Rs.1000/trip
Monitoring Costs : Construction Phase (Two years)-Distribution
Air Quality Monitoring once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs& Pipe line.
Noise level once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs& Pipe line..
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at Intake well, WTP (Akkammakonda), Sump/Pumhouse (Ramasagaram), ELSRs 7 Pipe line .
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5) with Tree Gaurds as per the Technical Specification
Sprinkling of water once in a day for two years (excluding rainy days): 500 days @ Rs.1000/trip
GOOTY MUNICIPALITY
Construction of 8.00 mt dia Intake wellwith Foot Bridge 200.00mts span over Columns, braces etc., including Formation of Earthen Ring Bund during construction and Approach for construction.
Excavation and removal of silt or silt mixed with sand in slussy condition including disposing off the same in spoil bank as directed etc., complete with initial lead upto 50 m and all lifts and as per Technical Specifications
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Excavation in all kinds of soil including boulders upto 0.30 m dia. for foundations and placing the excavated stuff neatly in specified dump area or disposing off the same as directed etc., complete with initial lead upto 50 m and initial lift upto 3 m by Manual Means and as per Technical Specification
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification.
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-10 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Vertical Side Wall(1000mm Thickness)
In-Take Well Vertical Wall +340.00 to +343.000
In-Take Well Vertical Wall +343.00 to +344.00
In-Take Well Vertical Wall +344.00 to +345.00
In-Take Well Vertical Wall +345.00 to +346.00
In-Take Well Vertical Wall +346.00 to +347.00
In-Take Well Vertical Wall +347.00 to +348.00
In-Take Well Vertical Wall +348.00 to +349.00
In-Take Well Vertical Wall +349.00 to +350.00
In-Take Well Vertical Wall +351.00 to +352.00
In-Take Well Vertical Wall +352.00 to +353.00
In-Take Well Vertical Wall +353.00 to +354.00
Vertical Side Wall(500mm Thickness)
In-Take Well Vertical Wall +354.00 to +355.00
In-Take Well Vertical Wall +355.00 to +356.00
In-Take Well Vertical Wall +356.00 to +357.00
In-Take Well Vertical Wall +357.00 to +358.00
In-Take Well Vertical Wall +358.00 to +359.00
In-Take Well Vertical Wall +359.00 to +360.00
In-Take Well Vertical Wall +360.00 to +361.00
In-Take Well Vertical Wall +361.00 to +362.00
In-Take Well Vertical Wall +362.00 to +363.00
In-Take Well Vertical Wall +363.00 to +364.00
In-Take Well Vertical Wall +364.00 to +365.00
In-Take Well Vertical Wall +365.00 to +366.00
In-Take Well Vertical Wall +366.00 to +367.00
In-Take Well Vertical Wall +367.00 to +368.00
For Cross Beams
For Floor Slab 0.2 m thickness
Columns
RCC Lintels
roof slab 0.15 m thickness
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications-Hand railing
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and fixing of Stain less steel for ladder and Railing made out of suitable sections for access from floor slab to Base slab as per Technical Specification
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS for internal walls and as per Technical Specification
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) and as per Technical Specification
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work and as per Technical Specification
Supply and fixing of 25 mm dia 2.0 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
Supply, delivery and erection of Raw Water Vertical Turbine Pump sets 3 Nos. of 79 KW each of discharge Capacity 3922 lpm against a head of 84.00mts including all Suction, Delivery Connections, Panel Board etc., Complete @ MPR Dam.
Clear & Raw Water Pumping Station.
Providing Raw Water Pumping system at Pennar Dam by supply, delivery and erection of VT pump set with specifications of Head range of 84 mtrs, discharge of 236 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer and with the following specifications and Equipment
Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing . 1 Unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. C. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. 1 Set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1 set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer -1 No
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare -2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station -1 Set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps-2 Sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel - 1 Set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)-1.00 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.1.00 Lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;-1 Set
Ring Spanner 3/16 to 1" -1 Nos
Double end spanner set 3/16" to 1"-1 Nos
Pipe Wrench 18" & 4"-2 Nos
Screw drivers 6", 10" & 12" -3 Nos
Cutting Plier 12" - 1 No
2 Kgs Hammer with Handle -1 No
Nose Plier -1 No
Flat and Half round smooth file- 2 Set
Adjustable Spanner 6"- 1 Set
Column pipe Clamps -2 pair
Line Shaft Clamps-1 Pair
Line rope and clamps double the weight of pump - 2 sets
Gland thghtening Spanner -1 No
Spitter removing Spanner - 1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete-1 Set
Fire extiguisher 3Kg capacity - 2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets - 1 Nos
Rubber Hand Gloves -1 No
Danger Board Plates - 4 Nos
First aid kit with chart - 1No
Shock Treatment Chart - 1No
Portable rechargeble torch light-1 No
Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc;-1 No
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer- 1 Set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection- 1Job
Pumping System::
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer and with the following specifications and equipments
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder-1 Set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 Set
Power transformer, required push buttons and MFM for each Main pump feeder-1 Set
Providing 315 KVA Transformers 11KV/433 V, Three Phase, Amorphous Metal Core including charges payable including charges payable to APCPDCL at MPR Dam.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating and with the following specification and Equipments Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
315KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APSPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 95 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460
Transformer yard
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by Manual Means.
Providing Plain cement concrete 1:3:6 using 40 mm metal with concrete machine mixing as approved by the department including cost and conveyance of all materials to site, machine mixing of concrete, all lifts, leads, delifts, centering, laying in position, vibrating, compacting, curing, removal of centering, all labour charges, tools and plants, and all other incidental and operational charges etc., completeas per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Construction of Pump Operators Quarters at Intake well
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Columns
Plinth beam
Roof beams
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end Windows
Roof slab 0.125m thick with 0.30m extension all sides
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification.
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Door -D - 1.20X2.10 m
Doors D1 - 1.00X2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
windows 1.20x1.20
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work as per the technical specification.
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per the technical specification.
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work as per the technical specification.
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per the technical specification.
Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per the technical specification.
Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brand for rain water pipes with clamps
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and Fixing of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with "P" or "S" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice110 mm dia
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI & GM fittings
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing GI union Ist Quality
Supply,Delivery Laying, Jointing and Testing of 450mm dia DI K - 9 Pumping Main from In - Take Tower to Raw Water GLBR over Hillock on Left side of Konepalli Village.
Earthwork in excavation for Pipe Line as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification by Manual Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of 450mm dia centrifugally cast (spun) Ductile Iron x K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
450mm dia DI K9 class pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (450mm dia)
450mm dia DI K9 class pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including cost of rubber gaskets and all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450mm dia DI K9 class pipes
Laying of PCC M20 Nominal Mix using 20 mm (SS-5) graded HBG m/c metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete for Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 2.5 Mpa D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
450mm dia Butterfly Valves (PN - 2.5)
Supply and delivery of PN 2.5 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
250mm dia Scour Valves (PN - 2.5)
80mm dia Sluice Valves (PN - 2.5)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
450mm dia Butterfly Valves (PN - 2.5)
250mm dia Scour Valves (PN - 2.5)
80mm dia Sluice Valves (PN - 2.5)
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia Isolated Airvalves ( (PN - 2.5)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification. (P.No.6, Sl.No.17).
80mm dia Isolated Airvalves ( (PN - 2.5)
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) of following dia. conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steel; including transportation and excluding all taxes complete as per technical specification. PN 2.5 (MPa).
450mm dia Non Return Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450 mm Dia Sluice Valves [2.20*2.20*1.90 Mts]
250 mm dia Scour Valves [2.00*2.00*1.80]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Air Valve Chamber-80mm [1.90*1.90*1.75 Mts]
Supply delivery and fixing of Structural Steel like Iron Girder I section including all Labour Charges hoisting and placing in position etc complete as per Technical Specification.
Construction of Raw Water GLBR of 300 KL Capacity on the Top of Hill at Konepalli Village
Excavation in hard rock (blasting prohibited) with Chiseller (Hammer Man) rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side walls
Beams Supporting Slab
Roof slab 0.2 m thickness
Column
Inside ring beam
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS for internal walls and as per Technical Specification
Supply and Delivery of H.D -20 as per BIS:12592 (Part 1&2) with 560 mm dia clear opening manhole covers and frames with ISI marking including cost and conveyance loading, un-loading and all labor charges and as per Technical Specification
Supply and fixing of Stain less steel for ladder and Railing made out of suitable sections for access from floor slab to Base slab etc complete as per Technical Specification
Laying of WBM Approach Road to Raw Water GLBR on Top of Hillock near Konepalli Village for a Length of 800.00mts Length.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Construction of granular surface course by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller / Vibratory Roller 80-100 kN capacity to achieve the desired density, complete as per MORTH 5th revision
Providing, laying, spreading and compacting stone aggregates of 63 mm nominal single size to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller/ Vibratory Roller 80-100 kN in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per MORTH 5th revision
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply, Delivery, Laying, Jointing and testing of 600mm dia DI K - 7 Raw Water Gravity Main for a Length of 52700.00mts from GLBR Near Konepalli Village to Proposed WTP at Peddavadugur Road,Gooty
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
600mm dia DI K - 7 Gravity Main
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
600mm dia Specials
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
600mm dia DI K - 7
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
600mm dia DI K - 7
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying of VCC M20 Nominal Mix using 20 mm m/c HBG metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete and as per Technical Specification for Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
600mm dia Sluice Valves
350mm daia Scour Valves
80mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
600mm dia Sluice Valves
350mm daia Scour Valves
80mm dia Sluice Valves
Supply and Delivery of PN 1.0D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia Isolated Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm dia Isolated Air Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
600mm dia Sluice Valves [2.35*2.35*2.10 Mts]
350mm daia Scour Valves [2.10*2.10*1.80 Mts
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Air Valve Chamber-80mm [1.90*1.90*1.75 Mts]
Road Restoration
Supply and filling with sand complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work as per technical specification.
Laying insitu VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Supply delivery and fixing of Structural Steel I section including cost and conveyance Labour Charges hoisting and placing in position and as per Technical Specification
Railway crossings / Road crossings / Canal crossings by trenchless technology tunneling work through specialized pipe jacking method in co-ordination with concerned authorities for as per approved drawings, installing to correct level gradient and alignment by hydralic pipe jacking technique complete including tunneling excavation drive and receive pits ,excavation and all machines tranaportation charges and other required materials but excluding cost of encasing pipe 800mm dia
Supply and delivery of M.S Spirally Welded Pipes conforming to IS: 3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar (1:3) 30mm thick by short crating or guniting duly providing wire mesh of size 50x50x3mm including cost of all materials, labor charges, transportation to anywhere in AP, but excluding all taxes.800mm dia 12mm Thk
Laying, Jointing, Hydrostatic filed test pressure, including cost of site welding, jointing materials and cost of transportation of water including emptying pipe line after completion of filed testing.800mm dia 12mm Thk
Construction of 11.00 MLD Capacity Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using sand as filter media, compatible with SCADA arrangements, duly following relevant IS codes in the design of plant components including trial running for 90 days etc., including chlorine contact tank & consumables etc., complete.
Construction of incomplete works of 11.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PHSSR 2025-26. All valves in the Filtration Plant should be compatable for operation with motorised Actuators integrated to SCADA.The present Stage of Work is appended in the Tender Document
Finishing works for 300 KL Clear Water Sump at WTP.
Supply and fixing of Stain less steel ladder made out of suitable sections for access from floor slab to Base slab etc Complete as per Technical Specification.
RCC ladders & Steps
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912. and as per Technical Specification
Supply and Delivery of H.D - 20 as per BIS:12592 (Part 1&2) with 560 mm dia clear opening manhole covers and frames with ISI marking including cost and conveyance loading, un-loading and all labor charges and as per Technical Specification
Recycling of Back Wash Water additional arrangements for Sludge Management such as Collection Well and Settling Tank with Pumping Arrangement to Pump the Back Wash Water Back in to Clariflocculator and for the disposal of Sludge, Centrifuge Arrangements / Sludge drying beds.
Supply, Delivery, Laying, Jointing and testing of 300mm dia DI K - 7 Gravity Main from Clariflocculator Sludge Outlet Pipe to Collection Well for a Length of 50.00mts.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
300mm dia DI K - 7 Pipes
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
300mm dia DI K - 7 Pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
300mm dia DI K - 7 Pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Construction of 100 KL Capacity 7.00 mts dia 3.00m deep Water Collection Well for Back Wash Water at WTP.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall 300mm
Roof Slab of 200 mm thick
Columns
Inside Ring Beam
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Supply and Delivery of H.D - 20 as per BIS:12592 (Part 1&2) with 560 mm dia clear opening manhole covers and frames with ISI marking including cost and conveyance loading, un-loading and all labor charges and as per Technical Specification
Supply, Delivery & Erection of 4 Nos. Centrifugal Pumpsets for Re-Cycling
Supply ,delivery,and erection of 2 Nos of Centrifugal sludge pumpsets capable of discharge of 9 lps againt head of 15 mts with combined efficiency of 60% to pump Back Wash Water from Sump to 11.00 MLD WTP with 100% stand by of standard make including suction, and delivery connections , Panel boards, cables, earthing arrangements, Non return valves, Butter fly valves , Providing thrust blocks, M.S specials and pipes connection upto puming main, , all taxes and duties, and all labour charges etc., complete including delivery connections upto pumping main.[8 Kw CF Pumpsets Each ]
Supply ,delivery,and erection of 2 Nos of Centrifugal sludge pumpsets of capacity having discharge of 9 lps againt head of 15 mts with combined efficiency of 60% to pump Back Wash Water from Sump to 11.00 MLD WTP with 100% stand by of standard make including suction, and delivery connections , Panel boards, cables, earthing arrangements, Non return valves, Butter fly valves , Providing thrust blocks, M.S specials and pipes connection upto puming main, , all taxes and duties, and all labour charges etc., complete including delivery connections upto pumping main.[8 Kw CF Pumpsets Each ]
Construction of 2 Nos. 27 x 8 x 2mts Sludge Disposal Beds at WTP.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By mechanical Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912. and as per Technical Specification
Laying, Jointing and Testing of 200mm dia DI K - 9 Pumping Main from WTP @ to WTP Aeartor for a Length of 150.00mts.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Supply, delivery and erection of Clear Water Pumpsets 3 Nos. of each 79 KW discharge 3735.00 lpm against a head of 84.00 mts for Pumping Clear Water from GLBR to GLBR on the Top of Hillock Kurnool Road.
Supply, delivery and erection of HSC pump set with specifications of Head range of 84 mtrs, discharge of 224 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer with the following Specifications and Equipments
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing . -1 unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.-1 set
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.-1 set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete -1 set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer - 1 No
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare -2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station - 1 Set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps-2 Sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel -1set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)-1.00 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.-1 Lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;-1 Set
Ring Spanner 3/16 to 1" -1 Nos
Double end spanner set 3/16" to 1"-1 Nos
Pipe Wrench 18" & 4"-2 Nos
Screw drivers 6", 10" & 12" -3 Nos
Cutting Plier 12" - 1 No
2 Kgs Hammer with Handle -1 No
Nose Plier -1 No
Flat and Half round smooth file-2 set
Adjustable Spanner 6"- 1 Set
Column pipe Clamps -2 pair
Line Shaft Clamps-1 Pair
Line rope and clamps double the weight of pump -2 set
Gland thghtening Spanner - 1 No
Spitter removing Spanner - 1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete-1 Set
Fire extiguisher 3Kg capacity -2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets - 1 Nos
Rubber Hand Gloves -1 Set
Danger Board Plates -4 Nos
First aid kit with chart -1 No
Shock Treatment Chart -1 No
Portable rechargeble torch light-1 No
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;-1 No
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,-1 Set
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer-1 Set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection-1 job
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer with the following Specifications and Equipments
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder-1 Set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 Set
Power transformer, required push buttons and MFM for each Main pump feeder-1 Set
Construction of Clear Watet Pump House 8.00 x 12.00 Size at WTP.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns Up to Ground Floor Roof Level
Beams 230 x 500
Foundation for Pumps
RCC Slab of 150 mm thickness
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per the technical specifiaction.Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Providing 315 KVA Transformer with Transformer Yard at WTP.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating and with the following specificaions and Equipments Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
315KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APSPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 95 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specificationby Manual Means.
Providing Plain cement concrete 1:3:6 using 40 mm metal with concrete machine mixing as approved by the department including cost and conveyance of all materials to site, machine mixing of concrete, all lifts, leads, delifts, centering, laying in position, vibrating, compacting, curing, removal of centering, all labour charges, tools and plants, and all other incidental and operational charges etc., complete as per specifications, drawings and as directed by the Engineer - in - Charge
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Supply,Laying, Jointing and Testing of 450mm dia DI K - 9 Clear Water Pumping Main from Clear Water Sump at WTP to to 1050 KL (GLBR+GLSR) over Hillock in Kurnool Road.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
450mm Dia DI K - 9 Class Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
450mm Dia DI K - 9 Class Pipe
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450mm Dia DI K - 9 Class Pipe
Laying of VCC M20 Nominal Mix using 20 mm m/c HBG metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete and as per Technical Specification for Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 2.5 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
450mm dia Valves PN 2.5
250mm dia Sluice Valves PN 2.5
80mm dia Sluice Valves PN 2.5
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
450mm dia Valves PN 2.5
250mm dia Sluice Valves PN 2.5
80mm dia Sluice Valves PN 2.5
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia Isolated Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm dia Isolated Air Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450mm dia Sluice Valves [2.20*2.20*1.90]
250mm dia Sluice Valves [2.00*2.00*1.75]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Air Valve Chamber-80mm [1.90*1.90*1.75 Mts]
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Providing WBM Approach Road to Clear Water GLBR on Top of Hillock.
Excavation in hard rock (blasting prohibited) with Chiseller (Hammer Man) rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Construction of granular surface course by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller / Vibratory Roller 80-100 kN capacity to achieve the desired density, complete as per Technical Specification
Providing, laying, spreading and compacting stone aggregates of 63 mm nominal single size to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with three wheel 80-100 kN static roller/ Vibratory Roller 80-100 kN in stages to proper grade and camber, applying and brooming, crushable screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 2 as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply, Delivery, Laying, Jointing and testing of DI Pipe Clear Water Gravity Main to All existing ELSRs and Proposed ELSR's in Gooty.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
450 mm dia DI K - 7 Pipes
350mm dia DI K - 7 Pipes
300mm dia DI K - 7 Pipes
250mm dia DI K - 7 Pipes
200mm dia DI K - 7 Pipes
150mm dia DI K - 7 Pipes
100mm dia DI K - 7 Pipes
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
450 mm dia DI K - 7 Pipes
350mm dia DI K - 7 Pipes
300mm dia DI K - 7 Pipes
250mm dia DI K - 7 Pipes
200mm dia DI K - 7 Pipes
150mm dia DI K - 7 Pipes
100mm dia DI K - 7 Pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450 mm dia DI K - 7 Pipes
350mm dia DI K - 7 Pipes
300mm dia DI K - 7 Pipes
250mm dia DI K - 7 Pipes
200mm dia DI K - 7 Pipes
150mm dia DI K - 7 Pipes
100mm dia DI K - 7 Pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.60 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Sluice Valves
450mm dia Sluice Valves
350mm dia Sluice Valves
300mm dia Sluice Valves
250mm dia Sluice Valves
200mm dia Sluice Valves
150mm dia Sluice Valves
80mm dia Sluice Valves
50mm dia Sluice Valves
Scour Valves
200mm dia Scour Valves
150mm dia Scour Valves
100mm dia Scour Valves
Supply and Delivery of PN 1.60 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia Isolated Air Valves
50mm dia Isolated Air Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification.
450mm dia Sluice Valves
350mm dia Sluice Valves
300mm dia Sluice Valves
250mm dia Sluice Valves
200mm dia Sluice Valves
150mm dia Sluice Valves
80mm dia Sluice Valves
50mm dia Sluice Valves
Scour Valves
200mm dia Scour Valves
150mm dia Scour Valves
100mm dia Scour Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm dia Isolated Air Valves
50mm dia Isolated Air Valves
Laying of RCC M20 Nominal Mix using 20 mm m/c HBG metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete and as per Technical Specification for Thrust Blocks, Pipe line pedastals etc and as per Technical Specification.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
400/450 mm [2.20*2.20*1.90 Mts]
300/350 mm [2.10*2.10*1.80 Mts]
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Air Valve Chamber-80mm [1.90*1.90*1.75 Mts]
Supply and filling withsand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Railway crossings / Road crossings / Canal crossings by trenchless technology tunneling work through specialized pipe jacking method in co-ordination with concerned authorities for as per approved drawings, installing to correct level gradient and alignment by hydralic pipe jacking technique complete including tunneling excavation drive and receive pits ,excavation and all machines tranaportation charges and other required materials but excluding cost of encasing pipe800mm disa
Supply and delivery of M.S Spirally Welded Pipes conforming to IS: 3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar (1:3) 30mm thick by short crating or guniting duly providing wire mesh of size 50x50x3mm including cost of all materials, labor charges, transportation to anywhere in AP, but excluding all taxes.500mm dia 8mm Thk
Laying, Jointing, Hydrostatic filed test pressure of MS pipe, including cost of site welding, jointing materials and cost of transportation of water including emptying pipe line after completion of filed testing 500 mm Dia 8 mm Thickness
Construction of 700 KL Capacity ELSR 10.00Mts Staging with SBC of 20 T/Sqm for Zone - III @ on the Top of Hill at Edgapeta (Zone - 3).
Construction & Completion of balance works of 700 KL Capacity M30 Grade desing mix VRCC ELSR 10.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Top of Hill at Edgapeta (Zone - 3) The present Stage of Work is appended in the Tender Document
Finishing Works for 1050 KL Clear Water GLSR on Hill Lock near Kurnool Road.
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912.as per Technical Specification
Supply and Delivery of H.D - 20as per BIS:12592 (Part 1&2) with 560 mm dia clear opening manhole covers and frames with ISI marking including cost and conveyance loading, un-loading and all labor charges and as per Technical Specification
Finishing Works for 900 KL Clear Water GLSR on SS Palli
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting to new walls with 2 coats of water proof cement paint of apporved brand and shade over a base coat of approved cement primer grade I making making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per SS 912.as per Technical Specification
Supply and Delivery of H.D - 20 as per BIS:12592 (Part 1&2) with 560 mm dia clear opening manhole covers and frames with ISI marking including cost and conveyance loading, un-loading and all labor charges and as per Technical Specification
Construction of Plant Operators Quarters at WTP .
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification Clause
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Providing PCC 1:4:8 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Columns
Plinth beam
Roof beams
Roof slab 0.125m thick with 0.30m extension all sides
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification-Ceiling
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Door -D - 1.20X2.10 m
Doors D1 - 1.00X2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
windows 1.20x1.20
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work as per the technical specification.
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work as per the technical specification.
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per the technical specification.
Providing two coats of Synthic enamil paint over new Iron works including cost and conveyance of all material and all labour charges etc complete as per Techncial Specification
Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brand for rain water pipes with clamps
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and Fixing of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with "P" or "S" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice110 mm dia
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI & GM fittings as per technical specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing GI union Ist Quality as per technical specification
Construction of Field Office cum Store Shed at WTP.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying insitu VCC M-10 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Plinth Beams
RCC Slab of 150 mm
Beams
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specifications
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Supply & Fixing of Powder Coated Mild Steel doors, frames & shutters made of Skin pass galvanized Iron sheet conforming to Base Steel as per IS 513 “D” Quality, Galvanized as per IS 277 with Hot Zinc Coating of 120 grams / Sq.Mtr with powder coating of thickness 60-65 Microns, frame with 1.2mm thick Skin pass Galvanized Iron sheet formed to single rebate profile of ize 100 mm X 58 mm and filled with in-fill Polyurethane foam, the Door Shutters are with 0.80 mm thick Skin pass Galvanized Iron Sheet formed to provide a 46 mm thick fully flush, double skin door shell with Lock Seam joints at stile edges, fitted with in-fill of Honeycomb Kraft Paper and coated with polyester powders of Pure polyester/ epoxy polyester or polyurethane powder for powder coating of thickness 60 – 65 microns and are coated with Zinc Phosphate Primer to receive any paint on site or finished with Thermosetting Polyurethane paint of Aliphatic Grade providing high levels of scratch resistance and durability, the Shutter provided with 6 MM clear float vision glass in Circular, Square or Rectangular shapes, Stainless Steel Ball Bearing Butt Hinges 3 mm thick fixed flush to the frame and shutter (Profile 102x76x3mm thick).Mortise Sash Lock with Lever Handles, Mortise Dead Bolt, etc for industrial, commercial, residential, cleanroom applications
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per Technical Specification. Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges, labour charges for dressing of flooring stones etc., complete for finished item of work, but excluding the cost of conveyance of all materials as per the technical specifications
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Construction of Compound Wall around the proposed water supply installations at WTP and GLSRs
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Excavation for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Plinth Beams
Pillers
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) complete as per the technical specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
supply, delivery and fixing of MS Gate of size 4x2m including all fixers like wall brackests blocking arrangments and channel and Wheel for Opening and Closing duly painted with redoxcied primer 1 coat complete as per the technical specification
Construction of SCADA Room (G + 1) 8.00 x 12.00 Size.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Laying VRCC M-20 grade cement concrete Nominal Mixusing 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification for Bed.
Laying VRCC M-20 grade cement concrete Nominal Mixusing 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.For Side Walls of Septic Tank.
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:4), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, including the cost of conveyance of all materials as per the technical specification
Flooring with Non Skid Ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, but including the cost of conveyance of all materials as per the technical specification
Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing in position ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work as per the technical specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification
Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work for Single leaf Door as per the technical specification
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per the technical speciification Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side 20 mm m/c HBG wide cross PVC sheet as gap insert for top & bottom rail, panelling of 10mm(+/-)( 5mm+5mm)” thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm m/c HBG width stuck on the interior side of the C channel using solvent cement, complete as per direction of Engineer–in–charge and as per the technical specification
Ventilators: Top Hung 2 '-0" x 2'-0" (609.6x609.6mm) outer frame section size of 46mm x 52 mm shutter frame section size of 46mm x 46 mm including cost and conveyance of all materials labour charges and as per Technical Specification
Supply and fixing of 25 mm dia 2.0 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-30 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
2.0TR, 5 Star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32 Makes: As per list of recommended brands as category II- Makes: / Blue Star / Daikin / Hitachi/Carrier / LG/Lloyd (prevailing models in the market)
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work
SSupplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work
Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work. BMW-I.20
Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work for all floors
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg
Supply and fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges etc complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines and inlet
20 mm dia nominal bore -from jn for of individual lines to toilets
15 mm dia nominal bore -for internal
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and Fixing of GI union Ist Quality etc complete as per Technical Specification
Providing Distribution System
Providing of Distribution system in Zone - I
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
90deg Elbow DN 315mm
45deg Elbow DN 315mm
Sliding Coupler DN 315mm
Flange Socket DN 315mm
Air tee 315x80
Reducer 315 x 250
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
250mm dia Sluice Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing of Distribution system in Zone - II
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification Clause
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply, & delivery of HDPE fittings conforming to IS 4984 - 1995 including transportation to any where in A.P, excluding excise duty, sale tax and specials etc., complete as per technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
Valve Chambbers
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing of Distribution system in Zone - III
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
90deg Elbow DN 315mm
45deg Elbow DN 315mm
Sliding Coupler DN 315mm
Flange Socket DN 315mm
Air tee 315x80
Reducer 315 x 250
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
300mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
300mm dia Sluice Valves
Valve Chambbers
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
300/350 mm [2.10*2.10*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Road Restoration
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing of Distribution system in Zone - IV
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Bends
90deg Elbow DN 250mm
90deg Elbow DN 315mm
45deg Elbow DN 200mm
45deg Elbow DN 315mm
Reducer
Reducer 200 x 160
Reducer 250 x 200
Reducer 315 x 250
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
300mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
300mm dia Sluice Valves
Valve Chambbers
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
300/350 mm [2.10*2.10*1.80 Mts]
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Road Restoration
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing of Distribution system in Zone - V
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
250 OD PVC 12.5
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
250 OD PVC 12.5
315 OD PVC 12.5
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Bends
90deg Elbow DN 250mm
90deg Elbow DN 315mm
45deg Elbow DN 200mm
45deg Elbow DN 250mm
45deg Elbow DN 315mm
Reducer
Reducer 250 x 200
Reducer 315 x 250
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
350mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
250mm dia Sluice Valves
350mm dia Sluice Valves
Valve Chambbers
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.20m Thk Bed, 0.15m Thk Base slab ,0.15m Thk cover slab and manhole cover
300/350 mm [2.10*2.10*1.80 Mts]
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Road Restoration
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing of Distribution system in Zone - VI
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery and incidental charges etc., complete as per Technical Specification
Excavation in hard rock (blasting prohibited) by Mechanical means with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Scour Valves
150mm dia Sluice Valves
200mm dia Sluice Valves
Jointing DI DF pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete. (Reference to specifications. BIS No.3114/1994.)
150mm dia
200mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
200/250 mm [2.00*2.00*1.80 Mts]
100/150 mm [1.80*1.80*1.50 Mts]
Road Restoration
Supply and filling with sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying Plain cement concrete (1:4:8) using 40mm with concrete mixer including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. for Road Restoration
Providing 15mm dia New House service connections and transfer of Existing house Service connections
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
Providing house service connections at house holds side in earthern roads
Providing house service connections at other side in earthern roads
Providing house service connections at other side in BT &CC roads
Providing house service connections at HH side in BT &CC roads
Providing SCADA System and 24X7 Water Supply
Instrumantation and Automation of the Pumping System:
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 250 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 200 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
500MM Dia Above Specification.
outlet of Raw Water Pumping Station at Pennar Dam
Raw Water GLBR at Konepalli
Inlet of Raw Water main at WTP
400MM Dia Above Specification.
Outlet of Clear Water Pumping station at Gooty
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge.
Reservoir Inlet Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
50MM Dia Above Specification.
Inlet of 60 KL Existing ELSR at Chandra priya colony
100MM Dia Above Specification.
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
150MM Dia Above Specification.
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
400MM Dia Above Specification.
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
50MM Dia Above Specification.
Inlet of 60 KL Existing ELSR at Chandra priya colony
100MM Dia Above Specification.
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
150MM Dia Above Specification.
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
400MM Dia Above Specification.
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
50MM Dia Above Specification.
Inlet of 60 KL Existing ELSR at Chandra priya colony
100MM Dia Above Specification.
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
150MM Dia Above Specification.
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
400MM Dia Above Specification.
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
50MM Dia Above Specification.
Inlet of 60 KL Existing ELSR at Chandra priya colony
100MM Dia Above Specification.
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
150MM Dia Above Specification.
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
400MM Dia Above Specification.
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 60 KL Existing ELSR at Chandra priya colony
Inlet of 300 KL Existing ELSR at PR Office
Inlet of 150 KL Existing ELSR at Saibaba talkies
Inlet of 250 KL Existing ELSR at Jangala colony
Inlet of 250 KL Existing ELSR at MDO office
Inlet of 150 KL Existing ELSR atold municipal office
Inlet of 120 KL Existing ELSR at SC colony
Inlet of 120 KL Existing ELSR at Tholla shop
Inlet of 200 KL Existing ELSR at BC colony
Inlet of 90 KL Existing ELSR at SC colony
Inlet of 900 KL Proposed GLSR at SS Palli
Inlet of 700 KL Proposed ELSR at Edga peta
Inlet of 1050 KL Proposed GLBR & GLSR at Kota
Outlet of 800 KLProposed GLBR & GLSR at Kota
Outlet of 250 KLProposed GLBR & GLSR at Kota
24 x 7 Water Supply :: DMA Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
200MM Dia Above Specification.
Inlet of DMA-1 under 900 KL ELSR at SS Palli
250MM Dia Above Specification.
Inlet of DMA-2, 3, 6 & 7 under 900 KL ELSR at SS Palli
300MM Dia Above Specification.
Inlet of DMA-4 under 900 KL ELSR at SS Palli
350MM Dia Above Specification.
Inlet of DMA-5 under 900 KL ELSR at SS Palli
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1 under 900 KL ELSR at SS Palli
250MM Dia Above Specification.
Inlet of DMA-2, 3, 6 & 7 under 900 KL ELSR at SS Palli
300MM Dia Above Specification.
Inlet of DMA-4 under 900 KL ELSR at SS Palli
350MM Dia Above Specification.
Inlet of DMA-5 under 900 KL ELSR at SS Palli
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
200MM Dia Above Specification.
Inlet of DMA-1 under 900 KL ELSR at SS Palli
250MM Dia Above Specification.
Inlet of DMA-2, 3, 6 & 7 under 900 KL ELSR at SS Palli
300MM Dia Above Specification.
Inlet of DMA-4 under 900 KL ELSR at SS Palli
350MM Dia Above Specification.
Inlet of DMA-5 under 900 KL ELSR at SS Palli
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1 under 900 KL ELSR at SS Palli
250MM Dia Above Specification.
Inlet of DMA-2, 3, 6 & 7 under 900 KL ELSR at SS Palli
300MM Dia Above Specification.
Inlet of DMA-4 under 900 KL ELSR at SS Palli
350MM Dia Above Specification.
Inlet of DMA-5 under 900 KL ELSR at SS Palli
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
Under 700 KL ELSR at Edgapeta
Under 800 KL ELSR at Hillock-beside model school
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2, 3, 4, 5, 6&7 under 900 KL ELSR at SS Palli
AMI Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
Under DMA-1 ,2,3,4,5,6& 7 under 900 KL ELSR at SS Palli with above specifications
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Job
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Job
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer -1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station at Gooty Municipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Gooty Municipality with the above specifications.
Providing for Implementation of Environmental Management Plan in the estimate for Gooty Municipality.
Monitoring Costs : Construction Phase (Two years)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
PUTTAPARTHI MUNICIPALITY
Construction of 8.00mt dia In - Take Tower along with Formation of Earthen Ring Bund during Construction and Approach to In - Take Tower with Foot Bridge 90.00mts long over Columns, braces etc., at Bukkapatnam Lake (Source).
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - Mechanical Means
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -Manual means
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification.
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
In-Take Well Vertical Wall +440.000 to +436.000
In-Take Well Vertical Wall +436.000 to 434.000
In-Take Well Vertical Wall +434.000 to +432.000
In-Take Well Vertical Wall +432.000 to +431.000
In-Take Well Vertical Wall +440.000 to +445.000
In-Take Well Vertical Wall +445.000 to 448.000
In-Take Well Vertical Wall +448.000 to +450.455
For Cross Beams
For Floor Slab 200 mm thick
Columns
Hand Raling
RCC Lintels
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification for Roof Slab (125mm Thick)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply delivery and erection of Quality Alluminium Ladder made of sections 3.15 mm thick 300mm wide and steps at 300mm apart using same alluminium section 3.15 mm thick for 3 Mts including construction of landing Platform at every 3 Mts interval including cost of Materials, Labour, incidentaletc., complete for finished item of work and as per Technical Specification
Laying insitu VRCC M-20 grade Nominal using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification -Along the Slop of Dam and For Pipe Line Pedustals
supply and delivery of cast iron pipes and fittings (spls.) Conforming to i.s. No. 7181/1986, 5531/1988, 3950/1979 and C.I.D. Joints confirming to is no.8794/1988 at site of work anywhere in a.p. Including, loading, unloading, transportation to site of work stacking at site transit risk and package, excluding taxes and duties. as per Technical specifiaction.-CI Sluice Gate for Intake Well
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification.
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification.
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification
Dewatering pipe line trenches etc, duly bailing out water from the pipe line trenches with oil engine driven pumpsets of 5 HP capacity, including hire charges, fuel charges and wages for Driver and Helper and all other incidental and operational charges including suction and delivery hose, lead of drain in to natural drain etc, complete as directed by the Engineer in Charge
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per Technical Specification
Lighting arrengements for Pump House S & F of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc., and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete.
Supply, Delivery and Erection of Raw Water Vertical Turbine Pumpsets 3 Nos. Capable of Discharging 3381.00 lpm against a Head of 62.00mts for Intake Tower at Bukkapatnam Lake to WTP Areator Near OM Santhi Temple.
Providing Raw Water Pumping system at Bukkapatnam lake by supply, delivery and erection of VT pump set with specifications of Head range of 62 mtrs, discharge of 202 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer with the Following specification and equipments.
Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. C. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Testing and maintanance of the complete equipment covered and trial run for 90 days at 8 hours per day after completion of errection
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity
Rubber Mat 6" x 4"
Fire Buckets with stand and three buckets
Rubber Hand Gloves
Danger Board Plates
First aid kit with chart
Shock Treatment Chart
Portable rechargeble torch light
Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer with the following Specifications and Equipments
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Providing 315 KVA Transformers 11KV/433 V, Three Phase, Amorphous Metal Core Wound Transformer including charges payable to APSPDCL and obtaining all permissions from APSPDCL at Bukkapatnam Lake.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - by manual means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying insitu VRCC M-20 grade design mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
column footings
columns
plinth beam
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by the Departmwntal authorities and as per Technical Specification (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work as per Technical Specificationfor gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Supply, Laying, Jointing and Testing of 450mm dia K - 9 Class Raw Water Pumping Main for a Length of 4950.00mts from Intake Tower at Bukkapatnam Lake to WTP Areator Near OM Santhi Temple.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
450mm dia DI K9 class pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450mm dia DI K9 class pipes
Laying insitu VRCC M-20 grade Nominal mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 2.5 Mpa D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
450mm dia Butterfly Valves (PN - 2.5)
Supply and delivery of PN 2.5 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
300mm dia Scour Valves (PN - 2.5)
80mm dia Sluice Valves (PN - 2.5)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
450mm dia Butterfly Valves (PN - 2.5)
300mm dia Scour Valves (PN - 1.6)
80mm dia Sluice Valves (PN - 1.6)
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm Isolated Air Valves
Supply and delivery of Air Cushion valves / Quick Released damped Air Valves (QRDA) as per latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge.
150mm dia Air Cushion Valve
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm dia Sluice Valves (PN - 1.6)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification for 150mm dia Air Cushion Valve.
150mm dia Air Cushion Valve
Supply, Delivery of PN 1.6 D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification
450mm dia Non Return Valves
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per the technical specification.
Supply and delivery of Rubber Packing including cost and conveyance Labour Charges and placing in position and as per Technical Specification
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover 400/450 mm DI sluice valves (2.20x2.20x1.90m)
Supply, delivery and fixing of Bolts and Nuts with Double Washers including cost and conveyance and all labour charges etc., complete and as per Technical Specification
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M-7.5 using 40 mm graded HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per the Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Construction of RCC Pillers across the HNSS Canal Crossings
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Laying of VCC M-7.5 using 40 mm graded HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per the Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Columns
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Design and Construction of 9.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PHSSR 2018-19. All valves in the Filtration Plant should be compatable for operation with motorised Actuators integrated to SCADA.
Construction of 300 KL Clear Water Sump of 10.00 mts dia 4.00m deep at WTP Near OM Santhi Temple.
Earthwork in excavation for structures as per drawing and technical specifications Cncluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification Mechanical Means.
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -mechanical means
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying insitu VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall 300mm thick
Roof Slab
Columns
Beams
RCC ladders & Steps
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Supply, Delivery, Laying, Jointing and testing of 300mm dia DI K - 7 Gravity Main from Clariflocculator Sludge Outlet Pipe to Collection Well for a Length of 50.00mts.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.-Ordinary rock (not requiring blasting)
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
300mm dia DI K - 7 Pipes
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
300mm dia DI K - 7 Pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
300mm dia DI K - 7 Pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Construction of 100 KL Capacity 7.00 mts dia 3.00m deep Water Collection Well for Back Wash Water at WTP.
Earthwork excavation in Ordinary Rock blasting not required for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -Mechanical means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall 300mm
Roof Slab
Columns
Inside Ring Beam
RCC ladders
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Supply, Delivery & Erection of 4 Nos. 8 KW each Centrifugal Pumpsets for Back Wash Water.
Supply ,delivery,and erection of 4Nos of Centrifugal pumpsets of capacity having discharge of 9 lps againt head of 15 mts with combined efficiency of 60% to pump Back Wash Water from Sump to 9.00 MLD WTP with 100% stand by of standard make including suction, and delivery connections , Panel boards, cables, earthing arrangements, Non return valves, Butter fly valves , Providing thrust blocks, M.S specials and pipes connection upto puming main, , all taxes and duties, and all labour charges etc., complete including delivery connections upto pumping main.
Construction of 2 Nos. 27 x 8 x 2mts Sludge Disposal Beds at WTP.
Earthwork in excavation for structures as per drawing and technical specificationsincluding setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -Mechanical
Earthwork excavation in Ordinary Rock blasting not required for pipe lines as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification -Mechanical means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete
Laying VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges, labour charges for dressing of flooring stones etc., complete for finished item of work, but excluding the cost of conveyance of all materials as per the Technical specification.
Supply, Laying, Jointing and Testing of 200mm dia DI K - 9 Pumping Main from WTP @ to WTP Aeartor for a Length of 150.00mts.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
200mm Dia DI K - 9 Class Pipe
Supply, Delivery, Laying, Jointing and testing of 400mm dia DI K - 7 Clear Water Gravity Main from WTP to Sump at (Near OM Santhi Temple) Sump at Beedupalli Junction for a Length of 2450.00mts.
Cutting open B.T. road surface (as well as asphalt concrete up to 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
400mm dia DI K - 7 Gravity Main
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
400mm dia DI K - 7 Gravity Main
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
400mm dia DI K - 7 Gravity Main
Jointing the D.I. Pipes, with Flanged ends including cost of jointing materials including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per Technical Specification
400mm dia DI K - 7 Gravity Main
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying of VCC M20 Nominal Mix using 20 mm m/c HBG metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete and as per Technical Specification for Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
400mm dia Sluice Valves
300mm daia Scour Valves
80mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
400mm dia Sluice Valves
300mm daia Scour Valves
80mm dia Sluice Valves
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm Isolated Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm Isolated Air Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
400mm dia Sluice Valves [2.20*2.20*1.90 Mts]
300mm daia Scour Valves [2.10*2.10*1.80 Mts]
80mm Isolated Air Valves [1.90*1.90.1.75 Mts]
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs as per Technical specification.
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work as per Technical Specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing 315 KVA Transformers 11KV/433 V, Three Phase, Amorphous Metal Core including charges payable to APSPDCL and obtaining all permissions from APSPDCL at Beedupalli Sump.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - by manual means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying VRCC M-20 grade design mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
column footings
columns
plinth beam
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification internal
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work in all floors.( APSS No.126) for pre cast slabs of culverts - RBR-FNDN-8 & Revised Data sl.No-5
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Manufacture, Supply, delivery and erection of Pumpsets including cost of VFD Control Panels 3 Nos. of each 22 KW discharge 1490.00 lpm against a head of 56.00mts for Pumping Clear Water from Sump to 500 KL ELSR on the Top of Hillock Beedupalli Village, Prasanthi Gram 500 KL ELSR and Yeddulakonda 1200 KL GLSR.
Supply, delivery and erection of HSC pump set with specifications of Head range of 56 mtrs, discharge of 90 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Flat and Half round smooth file - 2 Nos
Adjustable Spanner 6"
Column pipe Clamps - 2 pairs
Line Shaft Clamps - 1 Pair
Line rope and clamps double the weight of pump - 2 sets
Gland thghtening Spanner - 1 No
Spitter removing Spanner - 1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity - 2 Nos
Rubber Mat 6" x 4" - 2Nos
Fire Buckets with stand and three buckets - 1 No
Rubber Hand Gloves - 1 Sets
Danger Board Plates - 4 Nos
First aid kit with chart - 1No
Shock Treatment Chart - 1No
Portable rechargeble torch light - 1 No
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
Supply, delivery and erection of 5 tonnes capacity double girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of best quality 250 x 100 mm of standard make, including the required MS ISMC, MS angular iron, 5 tonne capacity travelling trolley and 5 tonne capacity chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
Testing and maintanance of the complete equipment covered and trial run for 90 days at 8 hours per day after completion of errection
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Supply, delivery and erection of Pumpsets including cost of VFD Control Panels 3 Nos. of each 35 KW discharge 1732.00 lpm against a head of 77.00mts for Pumping Clear Water from Sump to 500 KL ELSR on the Top of Hillock Bramhanapalli Village, Yenumula Palli 1500 KL ELSR Chitravathi Gutta 300 KL GLSR and Karnatakanagipalli 300 KL GLSR.
Supply, delivery and erection of HSC pump set with specifications of Head range of 77 mtrs, discharge of 104 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing .
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete.
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;
Incoming cable of suitable size of copper armoured cable 3.50 core of standard make from transformer to Panel Board including aluminimum cable tray
Ring Spanner 3/16 to 1"
Double end spanner set 3/16" to 1"
Pipe Wrench 18" & 4"
Screw drivers 6", 10" & 12"
Cutting Plier 12"
2 Kgs Hammer with Handle
Nose Plier
Flat and Half round smooth file
Adjustable Spanner 6"
Column pipe Clamps
Line Shaft Clamps
Line rope and clamps double the weight of pump
Gland thghtening Spanner
Spitter removing Spanner
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete
Fire extiguisher 3Kg capacity
Rubber Mat 6" x 4"
Fire Buckets with stand and three buckets
Rubber Hand Gloves
Danger Board Plates
First aid kit with chart
Shock Treatment Chart
Portable rechargeble torch light
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Supply, Laying, Jointing and Testing of 300mm, 150mm and 100mm dia DI K - 9 Clear Water Common Pumping Main from Beedupalli Sump to Yeddulakonda via Beedupalli Junction with Branch to Beedupalli ELSR, Prasanthi Gram Junction with another Branch to Prasanthi Gram ELSR and from Prasanthi Gram Junction to Yeddulakonda GLSR on the Top of Hillock.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
300mm Dia DI K - 9 Class Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
300mm Dia DI K - 9 Class Pipe
Jointing the DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
300mm Dia DI K - 9 Class Pipe
Laying of VCC M20 Nominal Mix using 20 mm m/c HBG metal and OPC, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing for 21 days etc.complete and as per Technical Specification for Thrust Blocks, Pipe line pedastals etc.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 2.5 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Sluive Valves 100mm dia
Scour Valves 100mm dia
Sluive Valves 150mm dia
Scour Valves 150mm dia
Sluive Valves 300mm dia
Scour Valves 300mm dia
Sluive Valves 80mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
Sluive Valves 100mm dia
Scour Valves 100mm dia
Sluive Valves 150mm dia
Scour Valves 150mm dia
Sluive Valves 300mm dia
Scour Valves 300mm dia
Sluive Valves 80mm dia
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm Isolated Air Valves
Supply, Supply and delivery of Air Cushion valves / Quick Released damped Air Valves (QRDA) as per AWWA, including transportation, etc., complete and including cost and conveyance and as per Technical Specification.
100mm Air Cushion valves 15Ksc
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm Isolated Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., completecomplete including all labor charges and as per Technical Specification.
100mm Air Cushion valves
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification PN 1.6 (MPa)
300mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Sluive Valves 100mm dia [1.80*1.80*1.50 Mts]
Scour Valves 100mm dia [1.80*1.80*1.50 Mts]
Sluive Valves 150mm dia [1.80*1.80*1.50 Mts]
Scour Valves 150mm dia [1.80*1.80*1.50 Mts]
Sluive Valves 300mm dia [2.10*2.10*1.80 Mts]
Scour Valves 300mm dia [2.10*2.10*1.80 Mts]
80mm Isolated Air Valves [1.90*1.90.1.75 Mts]
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs as per Technical specification.
Supply and delivery of Rubber Packing including cost and conveyance Labour Charges and placing in position and as per Technical Specification
Supply, delivery and fixing of Bolts and Nuts with Double Washers including cost and conveyance and all labour charges etc., complete and as per Technical Specification
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Supply, Laying, Jointing and Testing of 350mm, 250mm, 200mm, 150mm and 100mm dia DI K - 9 Clear Water Common Pumping Main from Beedupalli Sump to Karnatakanagipalli via Bramhanapalli Thanda Junction, Yenumula Palli Junction, another Branch Pumping Mian ELSR at Bramhanapalli Thanda on the top of Hiilock and another Branch Pumping Mian from Bramhanapalli Thanda Junction to Yenumula Palli ELSR and Yenumula Palli Junction to Chitravathi Gutta GLSR on the Top of Hillock.
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
200mm Dia DI K - 9 Class Pipe
250mm Dia DI K - 9 Class Pipe
350mm Dia DI K - 9 Class Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
200mm Dia DI K - 9 Class Pipe
250mm Dia DI K - 9 Class Pipe
350mm Dia DI K - 9 Class Pipe
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
100mm Dia DI K - 9 Class Pipe
150mm Dia DI K - 9 Class Pipe
200mm Dia DI K - 9 Class Pipe
250mm Dia DI K - 9 Class Pipe
350mm Dia DI K - 9 Class Pipe
Laying VRCC M-20 grade cement concrete Nominal M ix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 2.5 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Sluive Valves 100mm dia (PN - 2.5)
Scour Valves 100mm dia (PN - 2.5)
Sluive Valves 150mm dia (PN - 2.5)
Scour Valves 150mm dia (PN - 2.5)
Sluive Valves 200mm dia (PN - 2.5)
Scour Valves 200mm dia (PN - 2.5)
Sluive Valves 300mm dia (PN - 2.5)
Scour Valves 300mm dia (PN - 2.5)
Sluive Valves 80mm dia (PN - 2.5)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
Sluive Valves 100mm dia (PN - 2.5)
Scour Valves 100mm dia (PN - 2.5)
Sluive Valves 150mm dia (PN - 2.5)
Scour Valves 150mm dia (PN - 2.5)
Sluive Valves 200mm dia (PN - 2.5)
Scour Valves 200mm dia (PN - 2.5)
Sluive Valves 300mm dia (PN - 2.5)
Scour Valves 300mm dia (PN - 2.5)
Sluive Valves 80mm dia (PN - 2.5)
Supply and Delivery of PN 2.5 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm Isolated Air Valves (PN - 2.5 (Mpa))
Supply, Supply and delivery of Air Cushion valves / Quick Released damped Air Valves (QRDA) as per AWWA, including transportation, including cost and conveyance and as per Technical Specification
100mm 15 Kfc
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80mm Isolated Air Valves (PN - 1.6 Mpa)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., completecomplete including all labor charges and as per Technical Specification.
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves)PN - 2.5 conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification
350mm dia (PN 1.6)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Sluive Valves 100mm dia [1.80*1.80*1.50 Mts]
Scour Valves 100mm dia [1.80*1.80*1.50 Mts]
Sluive Valves 150mm dia [1.80*1.80*1.50 Mts]
Scour Valves 150mm dia [1.80*1.80*1.50 Mts]
Sluive Valves 300mm dia [2.10*2.10*1.80 Mts]
Scour Valves 300mm dia [2.10*2.10*1.80 Mts]
80mm Isolated Air Valves [1.90*1.90.1.75 Mts]
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs - as per Technical specification
Supply and delivery of Rubber Packing including cost and conveyance Labour Charges and placing in position and as per Technical Specification
Supply, delivery and fixing of Bolts and Nuts with Double Washers including cost and conveyance and all labour charges etc., complete and as per Technical Specification
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work.
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Construction of RCC Pillers across the Chitravathi River postions
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification.
Footings for River Crossing
Columns
Slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats, MS angles, MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs as per Technical specification
Supply, Laying, Jointing and Testing of 100mm dia DI K - 7 Clear Water Gravity Main (1500.00mt Length) from Yedula Konda 1200 KL GLSR to Existing 150 KL ELSR at Puttaparthi Town.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Manual Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
100mm dia DI K - 7 Class pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
100mm dia Gravity Main
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
100mm dia Gravity Main
Laying VRCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification-Nominal Mix
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves (PN 1.6)
100mm dia Scours Valves (PN 1.6)
80mm dia Sluice Valves (PN 1.6)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves (PN 1.6)
100mm dia Scours Valves (PN 1.6)
80mm dia Sluice Valves (PN 1.6)
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80 mm Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.
80 mm Air Valves
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm Sluice Valve Pits [1.80*1.80*1.50 Mts]
100mm Scour Valve Pits [1.80*1.80*1.50 Mts]
50mm Air Valve Pits [1.90*1.90*1.75 Mts]
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs as per Technical specifications
Supply and delivery of Rubber Packing including cost and conveyance Labour Charges and placing in position and as per Technical Specification
Supply, delivery and fixing of Bolts and Nuts with Double Washers including cost and conveyance and all labour charges etc., complete and as per Technical Specification
Road Restoration
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Construction of 500 KL Clear Water ELSR of 16.00 mts Staging on the Top of Hillock behind Beedupalli Village (Zone - 1).
Construction & Completion of 500 KL Capacity M30 Grade desing mix VRCC ELSR 16.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on the Top of Hillock behind Beedupalli Village (Zone - 1) . The present Stage of Work is appended in the Tender Document
Construction of 500 KL Clear Water ELSR of 10.00 mts Staging on the Top of Hillock behind Prasanthi Gram Village (Zone - 2).
Construction & Completion of 500 KL Capacity M30 Grade desing mix VRCC ELSR 10.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on the Top of Hillock behind Prasanthi Gram Village (Zone - 2). The present Stage of Work is appended in the Tender Document
Construction of 500 KL Clear Water ELSR of 10.00 mts Staging on the Top of Hillock behind Bramhanapalli Thanda Village (Zone - 8).
Construction & Completion of balance works of 500 KL Capacity M30 Grade desing mix VRCC ELSR 10.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on the Top of Hillock behind Bramhanapalli Thanda Village (Zone - 8). The present Stage of Work is appended in the Tender Document
Construction of 1500 KL Clear Water ELSR of 20.00 mts Staging on the Top of Hillock behind Yenumulapalli Village (Zone - 7).
Construction & Completion of balance works of 1500 KL Capacity M30 Grade desing mix VRCC ELSR 20.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2018-19 on the Top of Hillock behind Yenumulapalli Village (Zone - 7). The present Stage of Work is appended in the Tender Document
Construction of & Completion of balance works of 1200 KL Clear Water GLSR of 19.00 mts dia 4.50m deep on the Top of Hillock Peddakammavari Palli and Puttaparthi Road Junction behind Yeddula Konda. The present Stage of Work is appended in the Tender Document
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Manuall Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall 350mm thick
Roof Slab 150mm thick
Beams Supporting Slab
Columns
RCC ladders & Steps
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) and as per Technical Specification
Construction of 300 KL Zinc Alluminium Clear Water Tank on the Top of Hillock behind Puttaparthi Busstand (Chitravathi Gutta).
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by MechanicalMeans.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.-Ordinary rock (not requiring blasting) Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying insitu VRCC M-25 grade Nominal mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply, Supply, Delivery, Erection and Testing of “Zinc Aluminum Tank” for Drinking Water grade Storage purpose of effective Capacity 300 KL i.e. excluding free board of minimum depth of 300mm with a provision for suitable dead storage using BMT bluescope cape steel or colour bond sheets of zincallume steel corrugated panels pre-curved and dome roof with standard design consists of Hot Dipped galvanized trusses. Roof Sheets are to be so fixed with minimum laps and lap of a minimum 300mm and self supporting roof. The liners out of Food grade imported consist of heavy duty homogeneous impervious membrane with internal woven mat or scrim. All Nozzles (as per requirements at site) should be extended clear of the tank. The tank should be provided with Access Hatch & Ladders and Provision for Scour Drain Complete complete and as per Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves (PN - 1.6)
100mm dia Scour Valves (PN - 1.6)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
Construction of 300 KL Clear Water GLSR of 10.00 mts dia 4.00m deep on the Top of Hillock behind Karnatanagi Palli Village.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth RBR-FNDN-1 II-B
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VRCC M30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall 300mm thkick
Roof Slab 150mm thick
Beams Supporting Slab
Column
RCC ladders & Steps
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:3), 20mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Laying of Approach CC Road to Proposed ELSRs / GLSR's on the Top of Hillocks.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Construction of granular surface course by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with three wheel 80-100 kN static roller / Vibratory Roller 80-100 kN capacity to achieve the desired density, complete as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Construction of Pump Operator Quarters / Watchmen Quarters at Beddupalli Junction at Beedupalli Sump.
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -mechanical
Earthwork in excavation for structures as per drawing and technical specifications 1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification Ordinary rock (not requiring blasting) Mechanical Means Upto 3 m depth
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Plinth Beams
Ground Floor Roof Slab 125 mm thick
RCC Walls
Lintals
RCC Slab 125 mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Flooring with 100mm thick Cement Concrete 1:4:8, using 40mm metal, 100mm thick and 20 mm m/c HBG Cement Concrete surface (Ellis Pattern, 1st Sort) as per the technical specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) and as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Lighting arrengements Supply & Fixing of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc., and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete as per Technical Specification
Construction of Electrician Quarter at Beedupalli Pump House.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- Mechanical Means.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -Ordinary rock-Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Ground Floor Roof Slab 125 mm thick
RCC Walls
Lintals
RCC Slab 125 mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Flooring with 100mm thick Cement Concrete 1:4:8, using 40mm metal, 100mm thick and 20 mm m/c HBG Cement Concrete surface (Ellis Pattern, 1st Sort) as per the technical specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) and as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work as per Technical Specification
Lighting arrengements for Pump House including S & F of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc., and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete as per Technical Specification
Construction of Field Office cum Store Shed at Beedupalli Sump.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification-Mechanical
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -Ordinary rock-Mechanical Means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Plinth Beams
RCC Slab 125 mm thick
Beams
Lintals over Rolling Shutters
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per the technical specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and etc,, complete for finished item of work and as per the technical specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Providing and fixing pre-painted steel sliding window 2-Track with Two sliding shutters. Providing and fixing pre-painted steel sliding window 2-Track-2 panel sliding window fabricated from Roll-formed sections made of Galvanized steel colour coated/powder coated(Base Steel as per IS 513’D’ quality, Galvanized as per IS-277 with Zinc of 120GM/Sq.mtr) with total coated thickness of 0.58mm. Primer coat with apoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back-coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick. Section for external frame should be of 59x44 mm, section for shutter should be of 35x55 mm. The windows should be panelled with 5mm thick plane float glass. Corner bracket for internal and external frame made of glass filled Nylon. Gaskets are to be made of Ethyl Propylene Diamine Monomer(EPDM). The sections are to be cut to length, joined and assembled by means of corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self-expanding brackets & screws including 10mm square guard bars with 6” pitch (152.40mm) and all Taxes complete for finished item of work and etc,, complete for finished item of work and as per the technical specification Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Lighting arrengements for including S & F of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc., and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete as per Technical Specification
Construction of Compound Wall around the proposed Water Supply Installations like GLSRs, ELSRs and Beedupalli Sump etc.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - mechanical means
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Columns
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm m/c HBG thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs -as per Technical specification
Supply, delivery and fixing of Name board of size 2.5 x 1.00m in angular frame using 10 BWG CR sheet and necessary angular supports of size 65 x 65mm for a hight of 2.50mts are as in required at site of work as per the directions of Engineer-in-charge.
Supply distrubution and fixing, installation of Flowmeters, Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoring
Instrumantation and Automation of the Pumping System:
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Clear Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 200 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 150 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
250MM Dia Above Specification.
Outlet of Clear Water Pumping main at Pumping station--1
Outlet of Clear Water Pumping main at Pumping station--2
350MM Dia Above Specification.
outlet of Raw Water Pumping Station at Bukkapatnam lake
Outlet of 300KL Clear Water sump
400MM Dia Above Specification.
outlet of 300KL Sump
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge.
Reservoir Inlet Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
100MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thanda
200MM Dia Above Specification.
Inlet of 1200 KL Proposed GLSR at Yeddula konda
250MM Dia Above Specification.
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thanda
200MM Dia Above Specification.
Inlet of 1200 KL Proposed GLSR at Yeddula konda
250MM Dia Above Specification.
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
100MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thanda
200MM Dia Above Specification.
Inlet of 1200 KL Proposed GLSR at Yeddula konda
250MM Dia Above Specification.
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thanda
200MM Dia Above Specification.
Inlet of 1200 KL Proposed GLSR at Yeddula konda
250MM Dia Above Specification.
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Prasanth gramam
Inlet of 300 KL Proposed GLSR at Chitravathi gutta
Inlet of 300 KL Proposed GLSR at karnatanag palle
Inlet of 500 KL Proposed ELSR at Bedupalli
Inlet of 500 KL Proposed ELSR at Bramhanapalli thand
Inlet of 1200 KL Proposed GLSR at Yeddula konda
Inlet of 1500 KL Proposed ELSR at Yenumula palle gutta
24 x 7 Water Supply :: DMA Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
150MM Dia Above Specification.
Inlet of DMA-1 under 500 KL ELSR at Prasanthi gramam
200 MM Dia Above Specification.
Inlet of DMA-2 under 500 KL ELSR at Prasanthi gramam
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of DMA-1 under 500 KL ELSR at Prasanthi gramam
200 MM Dia Above Specification.
Inlet of DMA-2 under 500 KL ELSR at Prasanthi gramam
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
150MM Dia Above Specification.
Inlet of DMA-1 under 500 KL ELSR at Prasanthi gramam
200 MM Dia Above Specification.
Inlet of DMA-2 under 500 KL ELSR at Prasanthi gramam
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of DMA-1 under 500 KL ELSR at Prasanthi gramam
200 MM Dia Above Specification.
Inlet of DMA-2 under 500 KL ELSR at Prasanthi gramam
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
Under 500 KL ELSR at Beedupalli
Under 500 KL ELSR at Bramhanapalli Thanda
Under 1500 KL ELSR at Yenumalapalli
Under 1200 KL ELSR at EdgapetaPedda Kammavari palli
Under 300 KL ELSR at Chitravathi gutta
Under 300 KL ELSR at Karnatakanage palli
Under 150 KL ELSR at Existing ELSR puttaparthi town
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1&2 under 500 KL ELSR at Prasanthi gramam
AMR Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
Under DMA-1 & 2 under 500 KL ELSR at Prasanthi gramam with above specifications
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Job
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Job
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer -1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station atPuttaparthyMunicipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Puttaparthi Municipality with the above specifications.
Construction of SCADA Room (G +1) 8.00 x 12.00 Size.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification-Mechanical
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Laying Plain Cement concrete (M 20) Nominal Mix using 20mm metal using concrete mixer including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing, centering, shuttering etc.,complete as per technical specification for Bed.
Laying M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification M-30 design mix
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work.
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete unit 1.00 kgs as per Technical specifications
Supply and fixing of pre-painted steel openable windows base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 , finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm with 5 mm thick plain float glass fitted with Ethyl propylene Diamine monomer Gasket (EPDM) and handle made of high grade aluminium powder coated with frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work .
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per the technical specification.
Lighting arrengements for including S & F of 20mm dia 1.50mm thick PVC Pipe, Wiring with 2 runs of 14/0.3mm (1.0 Sq.mm) Fire Retardant (FR) P.V.C. insulated flexible copper cable (ISI MARK), Supply and fixing of 6A 3 pin wall plug socket with 6A switch control, Supply and fixing of batten holder / slanting holder, Supply and Transportation of 1x36/40W box type tube light luminaire with copper / VPIT Choke, condensor, starters etc., and 1No 36/40W tube etc., complete. and Labour Charges etc. Complete as per Technical Specification
Providing for Implementation of Environmental Management Plan in the estimate for Puttaparthi Nagar Panchayat.
I. Monitoring Costs : Construction Phase (Two years)
Air Quality Monitoring once in a month for three seasons during the construction period Sump, Clear water pipeline, ELSRs.
Noise level Monitoring once in a month for three seasons during the construction period at Sump, Clear water pipeline, ELSRs.
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period Sump, Clear water pipeline, ELSRs.
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5) with Tree Gaurds as per the Technical Specification
Sprinkling of water once in a day for two years (excluding rainy days): 200 days @ Rs.1000/trip.
Hiring for 1 No Vehicles for 24 Months during execution period.
Hiring for 1 Nos. Vehicles for 24 Months during execution period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,
Providing of Distribution system from Zone - 1 Beedupalli 500 KL ELSR to Beedupalli Village, Badenaik Thanda Village and Gonenaik Thanda Village for a Length of 8010.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges and incidental charges etc., complete-mechanical
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary and incidental charges etc., complete-manual
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations of cc drains and culverts,pipeline trenches upto 3.00m depth Ordinary rock RBR-FNDN-1 II-B-mechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
250mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
250mm dia (2.00*2.00*1.70 Mts)
50mm dia [1.90*1.90*1.75]
Road Restoration
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 2 Prasanthi Gram 500 KL ELSR to Prashanthi Gram Village for a Length of 4952.00mts including Road Restoration
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification upto 3.00m depth Ordinary rockmechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
250 OD HDPE Pipes
BENDS
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
250mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
250mm dia (2.00*2.00*1.70 Mts)
50mm dia [1.90*1.90*1.75]
Road Restoration
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 3 Yeddula Konda 1200 KL GLSR to Pedda Kammavari Palli Village and Puttaparthi Town Part - 1 for a Length of 12796.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification upto 3.00m depth Ordinary rock \mechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
250mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
250mm dia (2.00*2.00*1.70 Mts)
50mm dia [1.90*1.90*1.75]
Road Restoration
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 4 Puttaparthi Existing 150 KL ELSR to Puttaparthi Town Part - 2 for a Length of 4210.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by MechanicalMeans including all labour charges, machinary and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification upto 3.00m depth Ordinary rock -mechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
Road Restoration
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 5 Chitravathi Gutta 300 KL GLSR to Kovelagutta Palli Village and Puttaparthi Town Part - 3 for a Length of 4842.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Fixing of 50 mm Nominal Bore GI pipe Medium Grade properties & weight as per IS 1239 with GI fittings such as elbows tees couplings, nipples, plugs including excavation for trenches and refilling the trenches complete except for GI bends union excluding GST and as per the Technical Specification.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
40mm dia [1.90*1.90*1.75 Mts]
Road Restoration
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 6 Karnatanagipalli 300 KL GLSR to Karnatanagi Palli Village for a Length of 3242.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification upto 3.00m depth Ordinary rock mechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
40mm dia [1.90*1.90*1.75 Mts]
Road Restoration
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 7 Yenumula Palli 1500 KL ELSR to Yenumulapalli, Rayalavaripalli Village and Gokulam Area for a Length of 13379.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -Ordinary rock-Mechanical Means
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 as amended suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
150 mm dia DI K7
300mm dia DI K - 7
350 mm di k7
400 mm dia K7
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 as amended Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
150 mm dia DI K7
300mm dia DI K - 7
350 mm di k7
400 mm dia k7
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
150 mm dia DI K7
300mm dia DI K - 7
350 mm di k7
400 mm dia k7
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
300mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
300mm dia Sluice Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
250mm dia
300mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
250mm dia (2.00*2.00*1.70 Mts)
300mm dia ( 2.10*2.10*1.80 Mts)
40mm dia [1.90*1.90*1.75 Mts]
Road Restoration
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing of Distribution system from Zone - 8 Bramhanapalli Thanda 500 KL ELSR to Bramhanapalli ThandaVillage and Bramhanapalli Village for a Length of 5279.00mts including Road Restoration.
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges and incidental charges etc., complete
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges, machinary and incidental charges etc., complete
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 3.00m depth Ordinary rock -mechanical
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 as amended including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia Sluice Valves
100mm dia Scour Valves
150mm dia Sluice Valves
150mm dia Scour Valves
200mm dia Sluice Valves
200mm dia Scour Valves
250mm dia Sluice Valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia
150mm dia
200mm dia
250mm dia
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
50mm dia Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per Technical Specification.-50mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia (2.00*2.00*1.70 Mts)
200mm dia (2.00*2.00*1.70 Mts)
250mm dia (2.00*2.00*1.70 Mts)
40mm dia [1.90*1.90*1.75 Mts]
Road Restoration
Collection, Supply and filling of Stone dust from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification
Providing 15mm dia New House service connections and transfer of Existing house Service connections.
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe) (Augur boring with out damaging CC & BT Roads)
PROVIDING HOUSE SERVICE CONNECTION AT HOUSEHOLD SIDE IN CC AND BT ROADS
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling excluding HSC's fittings like Saddle,Elbows, ferrule and Adaptors
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE (Minimum 4.0 Mts MDPE pipe)
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS (Minimum 7.0 Mts MDPE pipe)
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS (Minimum 7.0 Mts MDPE pipe)
PROVIDING HOUSE SERVICE CONNECTION AT HOUSEHOLD SIDE IN CC AND BT ROADS
MADAKASIRA NAGARA PANCHAYATH
Construction of 6.00 m dia(113 KL) Raw water draw off well cum pump house and approach bridge 30.00 m in Akkampalli tank
Labour charges for lowering and keeping in position of /DI Sluice valves(with cap/with hand wheel), reflux valves and scour valves.350mm dia
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification.350mm dia
Supply & Delivery of manhole covers and frames of 24x24 HD 20 with ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site etc Complete as per Technical Specification
Supply and delivery and fixing of S.S 302 grade ladder as directed by the departmental authorities as per Technical Specification
Construction of pump house
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
RCC Sun shades 0.60m wide ,0.10m thick at fixed end and 0.05m at free end
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Top of roof slab
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Ground Floor)
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Parapet Wall)
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (Ground Floor)
Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (First Floor)
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting two coats with Snowsem of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers as per the technical speciifcation
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item as per the Technical Specification
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification.
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification.
Supply and Fixing of of Rcc jally of approved design 50mm thick including necessary accessories complete in all respectsincluding all and labour charges etc., complete for finished item of work as per the Technical Specification
Electrification and internal wiring
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.BLD-ELEC-9.7.35
For Approch Bridge
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) complete as per the technical specification
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate m/c HBG, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications as per the Technical Specification
Providing 350 mm D.I. K9 Raw water pumping mains from proposed draw off well cum pump house in Akkampalli tank to Proposed 5.00 MLD WTP at Gollahatti
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Collection and Supply of Stone dust for filling in pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH including cost and conveyance to work spot and all labour charges for filling, sectioning etc.complete as per S.S
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification (350 mm dia DI K9 )
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification-350mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification-350mm dia
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation, taxes etc. complete.
for scour 200 mm dia on 350mm lines
350 mm dia DIDF Pipes 1.00m long
Supply, delivery of D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding GST and other duties etc.,complete as per S.S. and as directed by the departmental authorities. for 350 mm dia Pumping main
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (For 350mm Dia)
200mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (350 mm Dia pipes)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (200 mm Dia pipes)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (80 mm Dia pipes)
Supply and delivery of 350 mm dia PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Supply and delivery of 200 mm dia PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Supply and Delivery of 80mm PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification (350mm dia Non Return Valves (PN 1.6)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
350 mm Dia
200 mm Dia
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per the Technical Specification (80 mm Dia)
Laying VRCC M-20 grade design mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification (for R.C.C Thrust blocks)
Construction of Anchor blocks with VCC (1:2:4) nominal mix using 20mm m/c HBG crushed metal from approved quarry including cost and conveyance of all materials, seignorage charges and all labour charges for machine mixing, laying, vibrating and curing including centering charges etc.,complete as perTechnical Specification and as directed by the departmental authorities. (For Anchor Blocks )
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover 350mm [2.10*2.10*1.80 Mts]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover 200mm dia [2.00*2.00*1.70 Mts]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover 100mm [1.80*1.80*1.50 Mts]
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open WBM Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work ( for Road restoration.)
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. ( for Road restoration.)
Supply and erection of 3# of 11.19Kw (15 HP)VT Pumpsets each with a duty of 37LPS and a total head of 21.00m (Two working and one stand bye)for pumping of Raw water draw off well cum pump house in Akkampalli tank to proposed 5.00 MLD WTPat Gollahatti for intermediate requirement 2033
Supply, delivery, erection and commissioning of reputed make Energy Efficiency as per BEE Vertical Turbine Pumpsets 3 Nos. of 11.19 KW Capable of Discharging each 37 lps operating at 21 mtrs head, with 50% standby and suitable capacity Vertical squirrel cage induction motor suitable for operation on 415 V +/- 10%, 50Hz +/- 5%, (Vertical solid shaft) of reputed make.(15% Overloading on BKW) including all taxes but excluding GST.with the following specifications and Equipments
Suitbale size Columns & Colum assembly length of not less than 45 Mts including bowl assemble, MOC for VT pump, Bell Mouth / Bowl CI - IS 210, Impeller / CF8M - Shafts - SS 410, Pipe / M tool - MS IS 2062 as approved by Department
Supply, delivery, erection and commissioning of control panel board with suitable capacity bus bar suitable to operate above 3 Nos of pump sets. The panel board is made of 16 gauge MS sheet metal cubical/industrial indoor type and duly painted with 2 coats of enamel paint.
a. Incoming MCCB – 1 no
b. FCMA Soft Starters.- 3 nos
c. Shunt capacitor with MCB - 3 nos
d. 315 A TPN SFU for starter o/g – 3 nos
e. VSS – 3 Nos
f. ASS – 3 Nos
g. Ammeters for motors – 3 nos
h. Spare TPN SFU – 1 no
i. Phase indicating lamps – 3 nos
j. ON/OFF push buttons with bulbs - 6nos
Supply, delivery, erection and commissioning of suitable size Incoming Copper armoured cable from transformer to Control panel board with Alluminimum cable tray
Supply, delivery, erection and commissioning of suitable size Copper armoured cable from panel board to starters and to motor with Alluminimum cable tray
Supply and errection of suitable diamer and length with minimum 10 mm thick MS Manifold as approved by the Department (Dia should not be less than 1.5 times the dia of the pumping main)
Supply and errection of suitable suction and delivery DI pipes and connections upto Manifold
Cable Joints with jointing material such as lugs, glands, adhesive tapes etc to join the above cables.
Supply, laying and fixing of 40 x 6 mm GI flat patti double earthing for electrical protection for motor, pump panel board efficiently earthing duly providing earth pits and filling with coal and salt and GI pipes 1 ½ x 6” long and bottom 2’ x 2’ GI plate welded as per IE rules and specifications with 1 ½ ‘ x 1 ½ ‘ earth pit chambers with brick masonary and top cover.
Fire Extinguisher buckets and other safety measures accessories
a. CO2 Fire extinguishers of 5 kgs each – 2 nos
b. First aid kits – 2 nos
c. 4 fire buckets with stand – 2 nos
d. Rubber mats – 2 nos
e. Rubber hand gloves – 3 pairs
f. Danger boards – 5 nos
All Civil works such as anchor blocks, trust blocks, platform for pannel board and cable trench etc, complete
Supply, delivery and erection of 5 tonnes capacity electrically operated double girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of best quality 250 x 100 mm of standard make, including the required MS ISMC, MS angular iron, 5 tonne capacity travelling trolley and 5 tonne capacity chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 12.80 m rate is inclusive of the cost of materials, labour charges, site welding etc., complete and as per Technical Specification
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
VFD Pumpsets with following specifications and Equipments
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Errection of 100 KVA Transformer at draw off well cum pump house in Akkampalli tank with Transformer yard 15.00x12.00m
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes : As per list of recommended brands as category I. MAT-04042 a 100KVA
1. Quantity : 1
2. Rated KVA : 100 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 35 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456
Transformer yard
Earthwork in excavation by Mechanical Means for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Laying PCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work as per Technical Specification for gates and grills
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Construction of Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using sand as filter media, compatible with SCADA arrangements, duly following relevant IS codes in the design of plant components including trial running
Design and Construction of 5.00 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PHSSR 2025-26 All valves in the Filtration Plant should be compatable for operation with motorised Actuators integrated to SCADA.
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
300 mm dia DI DF pipes from WTP to clear water sump 2m length
1.00 length vertical from WTP
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge (300mm Dia)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification 300 mm dia
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (For 350mm Dia)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification 300 mm dia
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -300mm dia[2.10*2.10*1.80 Mts]
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanically Means.
Construction of 9.00m dia(152.80KL) clear water storage sump at proposed 5.00 MLD WTP at Gollahatti
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
vertical wall 3.00m intial height 0.3 m thick below GL
vertical wall 3.00m intial height 0.3 m thick above GL
Columns 0.35 x 0.35m
Roof beams
Roof slab 150 mm Thick
Roof dome slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Painting two coats with Snowsem of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers and as per the Technical Specification
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications
Construction of pump house 15.00m x7.50m at clear water sump at WTP
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying of PCC M - 7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per Technical Specification
Laying of VCC M - 10 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Column footings
Pedestals
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 0.125m thick,
Sunshades ( 0.60m wide X 0.10m thick )
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Ground Floor
Parapet Wall
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification ( For Sealing)
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification ( For Flooring)
Painting two coats with Snowsem of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification.
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item (1.5x1.20 mts size) as per the Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers as per Technical Specifiaction
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and Fixing of of Cement Jali of approved design 50mm thick including necessary accessories complete in all respectsincluding all and labour charges etc., complete for finished item of work as per the Technical Specification
Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm ISI standard for rain water pipes with clamps
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.BLD-ELEC-9.7.35
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete BLD-ELEC-9.7.36
Providing 350 mm D.I. K9 clear water pumping mains from proposed clear water sump of 5.00 MLD WTP at Gollahatti to propoposed clear water sump by the side of existing 1250 KL clear water sump of RWS dept
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Earth work in excavation in Ordinary Rock ( not Requiring blasting ) of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Collection and Supply of Stone crusher dust for filling in pipe line trenches as per drawing and technical specification Clause 305.3.9 MORD & 304 MORTH including cost and conveyance to work spot and all labour charges for filling, sectioning etc.complete as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification (350 mm dia DI K9 )
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification.350mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification 350mm dia
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
for scours 2.00 m long DIDF pipes 350mm dia
350 mm dia DIDF Pipes 1.00m long
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (For 350mm Dia)
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (For 200mm Dia)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (350 mm Dia pipes)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (200 mm Dia pipes)
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (80 mm Dia pipes)
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge (350mm dia)
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge (200mm dia)
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge(80mm dia. PN16 )
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification (350mm dia Non Return Valves (PN 1.6)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification (350 mm dia)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification (200 mm dia)
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. (80 mm Dia)
Laying VRCC M-20 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification (for R.C.C Thrust blocks & Anchor blocks)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -350mm dia [2.10-2.10*1.80]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -200mm dia [2.00*2.00*1.70]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -100mm dia[1.80*1.80*1.50]
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open WBM Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work ( for Road restoration.)
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. ( for Road restoration.)
Supply and delivery of MS Dismantling Joints with both side flange end suitable for installation in between flange end pipes. These rates are including all taxes, transportation charges but excluding GST etc., complete as per the Technical Specification (350 mm Dia)
Supply and erection of 3# of 18.65Kw (25 HP) CF Pumpsets each with a duty of 31LPS and a total head of 45.00m (Two working and one stand bye) for clear water raising main from clear water sump to Proposed proposed clear water sump at existing 1250 KLRWS sump Melavoi
Supply, delivery, erection and commissioning of reputed make Energy Efficiency as per BEE Centrifugal Pumpsets 3 Nos. of 18.65 KW Capable of Discharging each 31 lps operating at 45 mtrs head, with 50% standby and suitable capacity Vertical squirrel cage induction motor suitable for operation on 415 V +/- 10%, 50Hz +/- 5%, (Vertical solid shaft) of reputed make.(15% Overloading on BKW) including all taxes but excluding GST.
Suitbale size Columns & Colum assembly length of not less than 45 Mts including bowl assemble, MOC for VT pump, Bell Mouth / Bowl CI - IS 210, Impeller / CF8M - Shafts - SS 410, Pipe / M tool - MS IS 2062 as approved by Department
Supply, delivery, erection and commissioning of control panel board with suitable capacity bus bar suitable to operate above 3 Nos of pump sets. The panel board is made of 16 gauge MS sheet metal cubical/industrial indoor type and duly painted with 2 coats of enamel paint.
a. Incoming MCCB – 1 no
b. FCMA Soft Starters.- 3 nos
c. Shunt capacitor with MCB - 3 nos
d. 315 A TPN SFU for starter o/g – 3 nos
e. VSS – 3 Nos
f. ASS – 3 Nos
g. Ammeters for motors – 3 nos
h. Spare TPN SFU – 1 no
i. Phase indicating lamps – 3 nos
j. ON/OFF push buttons with bulbs - 6nos
Supply, delivery, erection and commissioning of suitable size Incoming Copper armoured cable from transformer to Control panel board with Alluminimum cable tray
Supply, delivery, erection and commissioning of suitable size Copper armoured cable from panel board to starters and to motor with Alluminimum cable tray
Supply and errection of suitable diamer and length with minimum 10 mm thick MS Manifold as approved by the Department (Dia should not be less than 1.5 times the dia of the pumping main)
Supply and errection of suitable suction and delivery DI pipes and connections upto Manifold
Cable Joints with jointing material such as lugs, glands, adhesive tapes etc to join the above cables.
Supply, laying and fixing of 40 x 6 mm GI flat patti double earthing for electrical protection for motor, pump panel board efficiently earthing duly providing earth pits and filling with coal and salt and GI pipes 1 ½ x 6” long and bottom 2’ x 2’ GI plate welded as per IE rules and specifications with 1 ½ ‘ x 1 ½ ‘ earth pit chambers with brick masonary and top cover.
Fire Extinguisher buckets and other safety measures accessories
a. CO2 Fire extinguishers of 5 kgs each – 2 nos
b. First aid kits – 2 nos
c. 4 fire buckets with stand – 2 nos
d. Rubber mats – 2 nos
e. Rubber hand gloves – 3 pairs
f. Danger boards – 5 nos
All Civil works such as anchor blocks, trust blocks, platform for pannel board and cable trench etc, complete
Supply, delivery and erection of 5 tonnes capacity electrically operated double girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of best quality 250 x 100 mm of standard make, including the required MS ISMC, MS angular iron, 5 tonne capacity travelling trolley and 5 tonne capacity chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 12.80 m rate is inclusive of the cost of materials, labour charges, site welding etc., complete and as per Technical Specification
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
VFD Pumpsets
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Errection of 315 KVA Transformer at proposed 5.00 MLD WTP with Transformer yard 15.00x12.00m
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
315KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 70 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03458
Transformer yard
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by Manual Means.
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Construction wash water recirculation sump of 5.50m dia sump( 71.83 KL) at WTP
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
0 to 3m Depth
3 to 6m depth
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per the Technical SPecification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
For side walls circular 0.30m thick below GL
For side walls circular 0.30m thick above GL
Columns 0.30 x 0.30m
Roof beams
Roof slab 0.15m thick
Roof dome slab 0.15m thick
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Painting two coats with Snowcem of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers as per the technical speciifcation
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications Clauses 800, 900 and 1208.3 MORD.
Laying of 100 mm dia . DI K9 Pumping mains from wash water sump at WTP to Areator
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification (100 mm dia DI K9 )
Supply and delivery of Centrifugally cast (SPUN) ductile iron pressure pipes with flanged ends for water, gas and sewage conforming to I.S, 8329/2000 in standard working lengths of 4, 5, 5.5 & 6 meter for classification K9 suitable for push on joint (Rubber gasket and jointing) with cement mortar lining inside the pipes with outside zinc coating, rates are ex-factory, including transportion and excluding GST 100 mm dia 1.00m long DI DF pipes for sluice and non return valves 1+1
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification 100mm
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification 100mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge (100mm dia)
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification 100mm dia Non Return Valves (PN 1.6)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification (100 mm dia)
Lowering D.I. Pipes (all classes) and specials (fittings) with flanged ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (350 mm dia
Lowering D.I. Pipes (all classes) and specials (fittings) with flanged ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (100 mm dia
Jointing D.I. pipes and fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc. (350 mm dia
Jointing D.I. pipes and fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc. (100 mm dia
Laying VRCC M-20 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification (for R.C.C Thrust blocks)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -100mm dia[1.80*1.80*1.50 Mts]
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification. for thrust blocks
Supply and erection of 2# of 1.49KW(2.00HP) CF Pumpsets each with a duty of 5 LPS and a total hed of 12m ( one working and one stand bye) for pumping wash water to Areator for recirculation
Supply, delivery, erection and commissioning of reputed make Energy Efficiency as per BEE Centrifugal Pumpsets 2 Nos. of 14.9 KW Capable of Discharging each 31 lps operating at 12 mtrs head, with 50% standby and suitable capacity Vertical squirrel cage induction motor suitable for operation on 415 V +/- 10%, 50Hz +/- 5%, (Vertical solid shaft) of reputed make.(15% Overloading on BKW) including all taxes but excluding GST.
Suitbale size Columns & Colum assembly length of not less than 45 Mts including bowl assemble, MOC for VT pump, Bell Mouth / Bowl CI - IS 210, Impeller / CF8M - Shafts - SS 410, Pipe / M tool - MS IS 2062 as approved by Department
Supply, delivery, erection and commissioning of control panel board with suitable capacity bus bar suitable to operate above 3 Nos of pump sets. The panel board is made of 16 gauge MS sheet metal cubical/industrial indoor type and duly painted with 2 coats of enamel paint.
a. Incoming MCCB – 1 no
b. FCMA Soft Starters.- 3 nos
c. Shunt capacitor with MCB - 3 nos
d. 315 A TPN SFU for starter o/g – 3 nos
e. VSS – 3 Nos
f. ASS – 3 Nos
g. Ammeters for motors – 3 nos
h. Spare TPN SFU – 1 no
i. Phase indicating lamps – 3 nos
j. ON/OFF push buttons with bulbs - 6nos
Supply, delivery, erection and commissioning of suitable size Incoming Copper armoured cable from transformer to Control panel board with Alluminimum cable tray
Supply, delivery, erection and commissioning of suitable size Copper armoured cable from panel board to starters and to motor with Alluminimum cable tray
Supply and errection of suitable diamer and length with minimum 10 mm thick MS Manifold as approved by the Department (Dia should not be less than 1.5 times the dia of the pumping main)
Supply and errection of suitable suction and delivery DI pipes and connections upto Manifold
Cable Joints with jointing material such as lugs, glands, adhesive tapes etc to join the above cables.
Supply, laying and fixing of 40 x 6 mm GI flat patti double earthing for electrical protection for motor, pump panel board efficiently earthing duly providing earth pits and filling with coal and salt and GI pipes 1 ½ x 6” long and bottom 2’ x 2’ GI plate welded as per IE rules and specifications with 1 ½ ‘ x 1 ½ ‘ earth pit chambers with brick masonary and top cover.
Fire Extinguisher buckets and other safety measures accessories
a. CO2 Fire extinguishers of 5 kgs each – 2 nos
b. First aid kits – 2 nos
c. 4 fire buckets with stand – 2 nos
d. Rubber mats – 2 nos
e. Rubber hand gloves – 3 pairs
f. Danger boards – 5 nos
All Civil works such as anchor blocks, trust blocks, platform for pannel board and cable trench etc, complete
Supply, delivery and erection of 5 tonnes capacity electrically operated double girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of best quality 250 x 100 mm of standard make, including the required MS ISMC, MS angular iron, 5 tonne capacity travelling trolley and 5 tonne capacity chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 12.80 m rate is inclusive of the cost of materials, labour charges, site welding etc., complete and as per Technical Specification
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection
VFD Pumpsets
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder
Power transformer, required push buttons and MFM for each Main pump feeder
Construction of compound wall to proposed 5.00 MLD WTP Gollahatti
Constuction of compound wall with the following specifications 1. Earth work excavation for column footings ,providing sand bed in foundations (0.10mts Thk),providing CC 1:4:8 for foundations (0.10mts Thk),VRCC M 25 Design mix for column footings of Size (1.40*1.40*0.25 Mts),plinth beams(0.23*0.23 Mts),columns(0.23*0.23*min 1.50 Mts height above PB),Brick work in CM 1:6(1.50 Mts above PB), Plastering CM 1:5, Snowcem painting(2 Coats), etc complete
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers as per the technical speciifcation
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Construction of 15.00m dia (424.44 KL) clear water storage sump at Near Existing Sump 1250 KL of RWS Dept
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Earth work in excavation in ordinary rock required not blasting of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M-7.5 using 40 mm graded HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per the Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Raft slab
vertical wall 3.00m intial height 0.40 m thick below GL
vertical wall 3.00m intial height 0.40 m thick above GL
Columns
Roof beams
Roof slab 150 mm Thick
Roof dome slab 0.15m thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Painting two coats with Snowsem of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply delivery and installation of Protection MS grills with lock and key for equipment, instrumentations where ever necessary. This item shall, including cost, conveyance, etc complete as directed by the departmental officers as per the technical speciifcation
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications ( Minimum size of 0.25x0.275x1.0 Mts)
Providing 600 mm dia DI K9 pumping main from existing 700 mm dia clear water main of RWS dept to proposed clear water sump near existing 1250 KL clear water sump of RWS dept
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
700 mm dia 1.00m long DI DF pipes
600 mm dia 1.00m long DI DF pipes
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with Socket and Spigot type conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification (600 mm dia )
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (600 mm dia )
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (600 mm dia )
Lowering D.I. Pipes (all classes) and specials (fittings) with flanged ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (700 mm dia )
Lowering D.I. Pipes (all classes) and specials (fittings) with flanged ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification (600 mm dia 1.00m long DI DF pipes )
Jointing D.I. pipes, valves and fittings with flanged ends but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (700 mm Dia pipes)
Jointing D.I. pipes, valves and fittings with flanged ends but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (600 mm Dia pipes)
Supply and delivery of PN1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge 700mm dia
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge 600mm dia
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification (600mm dia Non Return Valves (PN 2.5)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification (700 mm dia)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification (600 mm dia)
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -700mm [2.30*2.30*2.00 Mts]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover -600mm [2.30*2.30*2.00 Mts]
Construction of 6.10x3.65m chlorine plant and store room near proposed clear water sump at existing 1250 KL clear water sump of RWS dept
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By manual Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification columns
Providing PCC 1:3:6 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as Per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Pedastals
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 125 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Ground Floor)
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Parapet wall
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (Ground Floor)
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (parapet)
Cement plastering using opc in cm(1:3) prop 12 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for ceiling
Cement plastering using opc in cm(1:3) prop 20mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for ceiling
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work (Windows 1.50x1.20m) and as per the Technical Specification Windows 1.50x1.20m
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete
Construction of watchman quarters near proposed clear water sump at existing 1250 KL clear water sump of RWS dept(proposed 5.00 MLD WTP) and at Akkampalli tank 3 no's-01
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By manual Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 125 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Loft slab 0.075m thick
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Ground Floor)
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Parapet wall
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (Ground Floor)
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (paraper)
Cement plastering using opc in cm(1:3) prop 12 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for walls out side & inside above 3.5 m Height
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as ss
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
doors D1 - 1.0X2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work (Windows 1.50x1.20m) and as per the Technical Specification
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for floorring
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
S&F of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.BLD-ELEC-9.7.35
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete BLD-ELEC-9.7.36
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work. and as per Technical Specification
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and Fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification out side & inside
Laying RCC M-20 grade cement concrete Nominal mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Construction of watchman quarters near proposed clear water sump at existing 1250 KL clear water sump of RWS dept(proposed 5.00 MLD WTP) and at Akkampalli tank 3 no's-02
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By manual Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification columns
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 125 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Loft slab 0.075m thick
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Ground Floor)
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Parapet wall)
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (Ground Floor)
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (paraper)
Cement plastering using opc in cm(1:3) prop 12 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for walls out side & inside above 3.5 m Height
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
doors D1 - 1.0X2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work (Windows 1.50x1.20m) and as per the Technical Specification
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. completeas per Technical Specification for floorring
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.BLD-ELEC-9.7.35
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete BLD-ELEC-9.7.36
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work. and as per Technical Specification
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and fixing GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
S&F 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD. -ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification SS out side & inside
Laying VRCC M-20 grade cement concrete Nominal using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specificationfor culvert slabs
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Construction of watchman quarters near proposed clear water sump at existing 1250 KL clear water sump of RWS dept(proposed 5.00 MLD WTP) and at Akkampalli tank 3 no's-03
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By manual Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification columns
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Lintel beams
Roof Beams
Roof slab 125 mm Thick
Sunshades 0.60m wide, 0.10m at fixed end and 0.05m at free end ,over doors and windows
Loft slab 0.075m thick
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Ground Floor)
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification (Parapet wall
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (Ground Floor)
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification (paraper)
Cement plastering using opc in cm(1:3) prop 12 mm thick including cost of material, labour ,curing etc. complete as per SS for walls out side & inside above 3.5 m Height
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply delivary and fixing RCC Jollys includnig cost and conveyance of all material and all labour charges for fixing etc complete as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per the Technical Specification
Door -D - 1.20X2.10 m
doors D1 - 1.0X2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work (Windows 1.50x1.20m) and as per the Technical Specification
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work as per the technical specification.
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per the technical specification.
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification for floorring
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enameal paint over primary coat of approved quality colour and over a primary coat including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply Delivety and fixing of PVC pipe of 4kg/cm2 of size 110mm dia single socket of reputed make for rain water pipes with clamps incluind all labor charges and incidental charges and as per the Technical specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour charges
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hylam sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing of SPN distrubution board with IP 42 protection (metal door) suitable for 3 phase ELCB-RCCB-FP isolator as incomer and 10 KA SP MCBS as out going including internal connection and labour charges for surface-flush mounting etc -- 63 A FP isolator-1 no for incomer,6-32A SP MCBS -18 Nos for out going
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.. Unit each
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete.BLD-ELEC-9.7.35
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete BLD-ELEC-9.7.36
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of worke and as per Technical Specification
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock unit each
Supplying and fixing of 25.4mm dia , 609.6mm long aluminium anodized towel rods with brackets and aluminium screws including cost and conveyance of all materials, labour charges , overheads & contractors profit for finished item of work. and as per Technical Specification
Supply of 110 mm dia 3m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.from toilets to septic tank
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice - ISI Brand and as per Technical Specification-110mm
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg - ISI Brand and as per Technical Specification
Supply and Fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI &GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and Fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--manual means upto 3m depth by manual means upto 3.00m depth
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification out side & inside
Laying VRCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification for culvert slabs
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Construction of RCC Retaing wall by the side of proposed 15m dia(424.44 KL) clear water storage sump at near existing sump 1250 KL of RWS dept
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanically Means.
Earth work in excavation in Ordinary Rock ( not Requiring blasting ) of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying of VCC M - 7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Raft slab
vertical wall 3.00m intial height 0.45 m average thick below GL
vertical wall 3.00m intial height 0.45 m average thick above GL
vertical wall 1.00m additional height over intial 0.45 m average thick above GL
vertical wall 2.00m additional height over intial 0.45 m average thick above GL
vertical wall 3.00m additional height over intial 0.45 m average thick above GL
vertical wall 4.00m additional height over intial 0.45 m average thick above GL
vertical wall 5.00m additional height over intial 0.45 m average thick above GL
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and Delivery of Unplasticised PVCs Pipes for potable water supplies conforming to IS : 4985/2000 (3rd revision) with bell ends (Socket) as per specification in light Grey/Natural Ivory Grey/ Any other Color (except White) inclusive of transportation to the sub-divisional stores anywhere in AP including all taxes except GST (40mm dia(10 kg/sqcm) for weep holes horizaltal @ 2.00mc/c50.00/2.00=25,vertical @ 1.00mc/c 7 nos)
Providing bedding with mixture of 40 & 20 mm size m/c metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Providing 450mm,400 mm,350mm ,300 mm,200mm , 150 mm D.I. K7 clear water gravity main from proposed 14.00m dia (526.28 KL ) clear water sump to proposed ELSRs of various zones
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Maechanical Means.
Earth work in excavation in ordinary rock not required blastering of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7&K9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
450 mm dia DI K7
150 mm dia DI K9
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
400mm dia
315mm dia
200mm dia
160mm dia
Lowering of D.I. socket and spigot Pipes and fittings carefully in to the trench and laying them true to alignment and gradient including all labour charges, sundries as per BIS No. 3114/85 etc., complete as per S.S and as directed by the departmental authorities.
450 mm dia DI K7
150 mm dia DI K9
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials and as per the Technical Specification.
400mm dia
315mm dia
200mm dia
160mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
450mm dia DI K7
150mm dia DI K9
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification ( for scours 2.00 m long DIDF pipes )
for scour 250 mm dia on 450mm lines
for scour 250 mm dia on 400mm lines
for scour 200 mm dia on 300mm lines
for scour 100 mm dia on 150mm lines
for sluice valves,non return valves 450 mm dia DIDF Pipes 1.00m long
for sluice valves,non return valves 400 mm dia DIDF Pipes 1.00m long
for sluice valves,non return valves 300 mm dia DIDF Pipes 1.00m long
for sluice valves,non return valves 150 mm dia DIDF Pipes 1.00m long-
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
90deg Elbow DN 160mm
90deg Elbow DN 200mm
90deg Elbow DN 250mm
90deg Elbow DN 315mm
90deg Elbow DN 400mm
45deg Elbow DN 160mm
45deg Elbow DN 200mm
45deg Elbow DN 250mm
45deg Elbow DN 315mm
45deg Elbow DN 400mm
22.50deg Elbow DN 160mm
22.50deg Elbow DN 200mm
22.50deg Elbow DN 250mm
22.50deg Elbow DN 315mm
22.50deg Elbow DN 400mm
Sliding Coupler DN 160mm
Sliding Coupler DN 200mm
Sliding Coupler DN 250mm
Sliding Coupler DN 315mm
Sliding Coupler DN 400mm
Flange Socket DN 160mm
Flange Socket DN 200mm
Flange Socket DN 250mm
Flange Socket DN 315mm
Flange Socket DN 400mm
Air tee 160x40
Air tee 200x40
Air tee 250x40
Air tee 315x80
Air tee 400x100
150 x 160 equal tee
200 x 200 equal tee
250 x 250 equal tee
315 x 315 equal tee
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
450mm Dia
Jointing D.I. pipes and fittings with rubber gasket Flanged Ends but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification (350 mm Dia pipes)
450mm Dia
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
450mm Ø DI D/F valve - PN16
400mm Ø DI D/F valve - PN16
300mm Ø DI D/F valve - PN16
150mm Ø DI D/F valve - PN16
for scour 250 mm dia on 450mm lines PN16
for scour 250 mm dia on 400mm lines PN16
for scour 200 mm dia on 300mm lines PN16
for scour 100 mm dia on 150mm lines PN16
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100mm dia. PN16 on 450 mm dia
80mm dia. PN16 on 400 mm dia
80mm dia. PN16 on 350 mm dia
80mm dia. PN16 on 300 mm dia
80mm dia. PN16 on 200 mm dia
80mm dia. PN16 on 150 mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
450 mm dia
400 mm dia
300 mm dia
250 mm dia
200 mm dia
150 mm dia
100 mm dia
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. as per Technical specification
80 mm Dia
100 mm dia
Laying VRCC M-25 grade design mix using 20 mm down size approved m/c HBG, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification (for R.C.C Thrust blocks)
Construction of Anchor blocks with M 25 nominal mix using 20mm HBG crushed metal from approved quarry including cost and conveyance of all materials, seignorage charges and all labour charges for machine mixing, laying, vibrating and curing including centering charges etc.,complete and as per Technical Specification and as directed by the departmental authorities. (For Anchor Blocks )
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
450 mm dia [2.20*2.20*1.90 Mts]
400 mm dia [2.20*2.20*1.90 Mts]
300 mm dia [2.10*2.10*1.80 Mts]
250 mm dia [2.00*2.00*1.70 Mts]
200 mm dia [2.00*2.00*1.70 Mts]
150 mm dia [1.80*1.80*1.50 Mts]
100 mm dia [1.80*1.80*1.50 Mts]
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm dia on 450 mm line (2.30x2.00x1.85 Mts)
80 mm dia on 400 mm line (2.30x2.00x1.85 Mts)
80mm dia. PN16 on 350 mm dia (2.30x2.00x1.85 Mts)
80mm dia. PN16 on 300 mm dia (2.30x2.00x1.85 Mts)
80mm dia. PN16 on 200 mm dia (2.30x2.00x1.85 Mts)
80mm dia. PN16 on 150 mm dia (2.30x2.00x1.85 Mts)
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open CC. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open WBM Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. ( for Road restoration.)
Supply and delivery of MS Dismantling Joints with both side flange end suitable for installation in between flange end pipes. These rates are including all taxes, transportation charges but excluding GST etc., complete as per the Technical Specification
450 mm dia
400 mm dia
350 mm dia
Supply and delivery of DI Dismantling Joints with both side flange end suitable for installation in between flange end pipes. These rates are excluding Excise duty, Taxes and including transportation charges etc., complete as Per technical Specification
300 mm dia
200 mm dia
150 mm dia
Construction & Completion of balance works of 300 KL Capacity M30 Grade desing mix VRCC ELSR 12.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Begarlapalli (Zone - 1) . The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 300 KL Capacity M30 Grade desing mix VRCC ELSR 16.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Golla Hatti (Zone - 2) . The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 300 KL Capacity M30 Grade desing mix VRCC ELSR 18.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Maruthi nagar (Zone - 3) . The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 700 KL Capacity M30 Grade desing mix VRCC ELSR 20.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Govt junior college (Zone - 4) . The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 600 KL Capacity M30 Grade desing mix VRCC ELSR 12.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Boyagiri (Zone - 5) The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 300 KL Capacity M30 Grade desing mix VRCC ELSR 15.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on Mallinakani palli (Zone - 6) The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 500 KL Capacity M30 Grade desing mix VRCC ELSR 16.00 Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 on New SC Colony (Zone - 7) . The present Stage of Work is appended in the Tender Document
SCADA system is provided for ELSR's, Pumping & Gravity Mains
Instrumantation and Automation of the Pumping System:
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 150 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
300MM Dia Above Specification.
outlet of Raw Water Pumping Station at Akkam palli tank
Inlet of Raw Water main at WTP
Outlet of Clear Water Pumping main at Pumping station
Outlet of 424.44 KL Clear Water SUMP at Pumping station
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge.
Reservoir Inlet Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
150MM Dia Above Specification.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 500 KL Proposed ELSR at Begarlapalli
Inlet of 500 KL Proposed ELSR at Golla hatti
Inlet of 700 KL Proposed ELSR at Govt junior college
Inlet of 500 KL Proposed ELSR at Maruthi nagar
Inlet of 500 KL Proposed ELSR at New SC colony
Inlet of 500 KL Proposed ELSR at Mallinayaka palli
Inlet of 600 KL Proposed ELSR at Boyagiri
24 x 7 Water Supply :: DMA Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
150MM Dia Above Specification.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
150MM Dia Above Specification.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
Under 500 KL ELSR at Begarlapalli
Under 500 KL ELSR at Gollahatti
Under 500 KL ELSR at Maruthi nagar
Under 500 KL ELSR at new sc colony
Under 500 KL ELSR at mallinayakana palli
Under 600 KL ELSR at Boyagiri
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1 under 700 KL ELSR at Govt. Junior College
AMR Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
Under DMA-1 ,2,3,4,5,6& 7 under 900 KL ELSR at SS Palli with above specifications
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Job
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Job
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer -1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station at Madakasira Municipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Madakasira Municipality with the above specifications.
Central Station at Ananthapuram Circle Level Madakasira :
Establishment of HARDWARE for Central Control Station at Individual Circle ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Central control station where the SCADA room will be developed by the local Circle for operting & View from Service Reservoirs, DMA and AMI meter management for entire circle where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Supply and commissioning of Floor mounted/Rack server Dual Processor, 8 GB Ram x 2 Nos, Hard Disk - x 3 Nos of 1TB with raid control, Licensed OS, Mouse, keyboard and relevant accessories make of IBM/LENOVA/HP/DELL complete -1 Job
86" Interactive Display make of SENSES/ LG/ SAMSUNG/ BENQ or euilant with ethernet/HDMI/VGA supported for front end view of SCADA for monitoring, Graphical or Trends, MIS reports for the group of ULB,s or individual ULB under the circle with required cables and connectors etc., complete.-1 Job
16 port Unmanaged Switch with specifications of 220 V.AC/ 24 V.. DC., 16 No of LAN ports, Rack Mounted, Speed 100/1000 Mbps, compatable with make of CISCO/ HP/ FF/ ONV/ phoenix complete -1 No
Desktop PC Station with specification of I 7 or equilant Processor, 8 GB Ram, 512Gb SSD, Licensed OS, 24" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Nos3
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank for 1 Hr. back up, make of Vertiv/ EATON/ BPE/ NUMERIC /RIELLO / ENERTECH or equilant make complete -1 Nos
Fire wall application make of SOPHOS/ FORTINET or equilant make.-1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Central Unit with above specifications for Ananthapuram PH Circle.
AMR Water Meter Management System: Providing, deploy and Run the AMR software to collect the data from all AMR integrated Mechanical water Meters Installed in field with the specifications of provide mobile app to get the field data of consumer including geo mapping to synchronize with AMR software, the AMR software must have the capability to decrypt the received data from water meter and ensure data integrity, the software shall give output, at least in the CSV (Comma Separated Value)/ txt/ xls format, the AMR software must be capable of running on any standard PC/ MAC/Android/iOS devices, the AMR software should be cloud based and should have web portal access so that user can view customer data through browser, the AMR software should have an option for individual customer to view their meter consumption data through Web portal/ Mobile APP of Android or iOS, the AMR software shall allow the PC operator to review and edit any account in the AMR software, the AMR software should have the facility to export CSV/Txt/xls files in the pre-defined format by utility to billing system, the AMR software shall enable the client to specify the data to be exported from the database for transferring to billing system, the AMR Software shall be able to show meter status as meter not okay, reading not reliable, meter maintenance required etc., the AMR software should have capability to add additional customer information and create customizable data fields, the AMR software should manage GPS data of AMR Meters, the AMR Software have facility to generate customized MIS reports, the AMR software can store the historical data up to minimum two years, the AMR software have to generate the alarms /alerts regarding abnormalities of the Water Meter, the AMR software have data integrity feature with standard industrial security protocol, the Mobile App having the facility to configure the AMR water meter via Bluetooth, the AMR software have facility to generate the NRW reports by synchronizing the data from SCADA software, the AMR software have facility to generate the Consumption/Billing alerts via SMS / What’s App / e-Mail, AMR software needs to follow responsive software guidelines by Indian government, AMR software should have an option to create multiple users, AMR software should implement permission managemtnt for users - so that user can access only permitted Modules / Screens, AMR software should have Block IP mechanism, AMR software has to protected from DDOS attacks, AMR software should be implemented with Less latency standard industrial technologies, the information transfer from database to application should be done in a secured channel charges including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer Note: Detailesd technical specifications enclosed as Anexure-C
Development of Softwares for Central Control Station at Circle Level :
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Central control station where the SCADA room will be developed by the Circle for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Central Unit with above specifications for Ananthapuram PH Circle.
Construction of SCADA Control Room at Filtration Plant Site
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Manual Means
Supply and filling with stone cruhser dust complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for Bed.
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work as per the Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work as per the Technical Specification
Flooring with Non Skid Ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work as per the Technical Specification, but including the cost of conveyance of all materials
Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing in position ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work as per the Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, One Coat (All Colours) etc Complete as per the Technical Specification
Painting to new walls with 2 coats of plastic emulsion paint of approved brand and shade after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per the Technical Specification for internal walls.
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, One Coat (All Colours) etc Complete as per the Technical Specification
Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work for Single leaf Door as per the technical specification
Supply of 2.0TR, 5 Star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32 Makes: As per list of recommended brands as category II -Blue star / Hitachi / Daikin/Lloyd (prevailing models in the market)
Zone-I with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
100mm dia
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materialsas per the Technical Specification.
100mm dia
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
160mm dia.
c) End Caps
110mm dia.
160mm dia.
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
e) TEES
110mm dia.
160mm dia.
F)Bends
110mm dia.
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as Per Technical Specification
90deg Elbow DN 110mm
45deg Elbow DN 110mm
22.50deg Elbow DN 110mm
11.25deg Elbow DN 110mm
Sliding Coupler DN 110mm
Flange Socket DN 110mm
Air tee 110x40
110 x 100 equal tee
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100 mm dia
150mm dia
Lowering, keeping in position and fixing Kinetic air valves including all labor charges and incidental charges and as per Technical Specification
80 mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Cutting open Water Bound Macadam Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-II with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
End Caps
110mm dia. HDPE
160mm dia. HDPE
200mm dia. HDPE
110mm dia.
160mm dia.
Bends
110mm dia.
200mm dia.
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200mm dia.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
150mm dia
200mm dia
250mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100 mm dia
150mm dia
200mm dia
250mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm & 150 mm dia valves [1.80*1.80*1.50 Mts]
200mm & 250 mm ida valves [2.00*2.00*1.70 Mts]
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Cutting open Water Bound Macadam Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-III with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
110 mm dia for Air TEEs
160mm dia.
160 mm dia for Air TEEs
200mm dia.
200 mm dia for Air TEEs
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
200x225 mm dia
225x250 mm dia
250x280 mm dia
280x315 mm dia
315x355 mm dia
e) TEES
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200mm dia.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
200mm dia
250mm dia
300mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100 mm dia
150mm dia
200mm dia
250mm dia
300mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm & 150 mm dia valves [1.80*1.80*1.50 Mts]
200mm & 250 mm ida valves [2.00*2.00*1.70 Mts]
300mm & 350 mm dia valves [2.10*2.10*1.80 Mts]
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Cutting open Water Bound Macadam Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Collection, Supply and filling of sand from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete for road restoration
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-IV with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
110 mm dia for Air TEEs
160mm dia.
160 mm dia for Air TEEs
200mm dia.
200 mm dia for Air TEEs
250mm dia.
250 mm dia for Air TEEs
315 mm dia for Air TEEs
355mm OD OPVC
355 mm dia for Air TEEs
c) End Caps
160mm dia.
200mm dia.
250mm dia.
355mm OD OPVC
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
225x250 mm dia
250x280 mm dia
280x315 mm dia
315x355 mm dia
e) TEES
110mm dia.
160mm dia.
200mm dia.
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200mm dia.
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materialsas per the Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
150mm dia
200mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
300mm dia for distrubution
350mm dia for distrubution
for scour
100mm dia on 110 mm and 160 mm dia mains
150 mm dia on 200 and 250 mm dia lines
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Cutting open Water Bound Macadam Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-V with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materialsas per the Technical Specification.
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
110 mm dia for Air TEEs
160mm dia.
200mm dia.
c) End Caps
110mm dia.
160mm dia.
200mm dia.
250 mm dia for Air TEEs
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
200x225 mm dia
225x250 mm dia
e) TEES
110mm dia.
160mm dia.
200mm dia.
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST
90deg Elbow DN 110mm
90deg Elbow DN 160mm
45deg Elbow DN 110mm
45deg Elbow DN 160mm
22.50deg Elbow DN 110mm
22.50deg Elbow DN 160mm
11.25deg Elbow DN 110mm
11.25deg Elbow DN 160mm
Sliding Coupler DN 110mm
Sliding Coupler DN 160mm
Flange Socket DN 110mm
Flange Socket DN 160mm
Air tee 110x40
Air tee 160x40
Reduer 110x 90
Reduer 160x110
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200mm dia.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
150mm dia
200mm dia
300mm dia
350mm dia
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100 mm dia
150mm dia
200mm dia
250mm dia
300mm dia
350mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Dust filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm & 150 mm dia valves [1.80*1.80*1.50 Mts]
200mm & 250 mm ida valves [2.00*2.00*1.70 Mts]
300mm & 350 mm dia valves [2.10*2.10*1.80 Mts]
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-VI with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
110 mm dia for Air TEEs
160mm dia.
160 mm dia for Air TEEs
200mm dia.
200 mm dia for Air TEEs
c) End Caps
110mm dia.
160mm dia.
200mm dia.
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
e) TEES
110mm dia.
160mm dia.
200mm dia.
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200mm dia.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
150mm dia
200mm dia
Jointing the DI. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85.
100 mm distrubution
150mm dia for distrubution
200mm dia for distrubution
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Zone-VII with HDPE & OPVC Pipes
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges and as per the technical specification
Earthwork excavation for Pipe Line trench as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinery charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means including all labour charges & incidental charges
Earthwork excavation for Pipe Line trench in ordinary rock and blasting not required as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means including all labour charges, machinary & incidental charges
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 and amended including cost and transportation to site of work and stacking as per standards all taxes and duties but excluding GST and as per the Technical Specification
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST as per Technical Specification
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as Per technical Specification
90deg Elbow DN 315mm
45deg Elbow DN 315mm
22.50deg Elbow DN 315mm
11.25deg Elbow DN 315mm
Lowering, laying and jointing of HDPE pipes and jointing by butt fusion welding as per IS 7634-part-II/1975 as amended from time to time to the alignment and gradient and testing the pipeline to required pressure etc.complete as per Technical Specification
110mm dia.
160mm dia.
200mm dia.
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for PVC-O pressure pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materialsas per the Technical Specification.
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
100 mm dia
150mm dia
200mm dia
250mm dia
300mm dia
350mm dia
Labour charges for lowering and keeping in position of D.I. Sluice valves, reflux valves and scour valves. as per Technical Specifications
100 mm distrubution
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including all labor charges and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges and as per Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification.
Providing House Service Connections
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE IN EARTHEN ROADS
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS
PROVIDING HOUSE SERVICE CONNECTION AT HOUSEHOLD SIDE IN CC AND BT ROADS
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling excluding HSC's fittings like Saddle,Elbows, ferrule and Adaptors
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD SIDE IN EARTHEN ROADS
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN EARTHEN ROADS
PROVIDING HOUSE SERVICE CONNECTIONS AT HOUSEHOLD OPPOSITE SIDE IN CC &BT ROADS
PROVIDING HOUSE SERVICE CONNECTION AT HOUSEHOLD SIDE IN CC AND BT ROADS
Providing for Implementation of Environmental Management Plan in the estimate for Gooty Municipality.
Monitoring Costs : Construction Phase (Two years)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
GUDUR NAGARA PANCHAYATH
Construction of 8.0 mt dia RCC Intake well cum Pump House, Coffer Dam and RCC Walkway Bridge at Sunkesula Reservoir
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Upto 2.0 mtrs depth
Excavation in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm m/c down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Raft Slab at +0.00 mts
Sidewalls of intake well from +0.00mts to +3.00 Mts
Side wall from +3.00mts to +4.00mts
Sidewalls from +4.00mts to +5.00mtrs
Sidewalls from+5.00mts to +6.00mts
Sidewalls from +6.00 mts to +7.00mts
Side wall from +7.00mts to +8.00mts
Sidewalls from +8.00mts to +9.00mtrs
Sidewalls from+9.00mts to +10.00mts
Sidewalls from +10.00 mts to +11.00mts
Sidewalls from +11.00 mts to +12.00mts
Sidewalls from +12.00 mts to +13.00mts
Sidewalls from +13.00 mts to +14.00mts
Floor Slab (300 mm thick) at level +14.20mts
Columns from floor level to Roof level i.e from +14.2mts to +22.00 mts
Lintel Beam above rolling shutters and windows
Sunshades
Ring beam at support of crane
Roof Beams
Roof Slab 125mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:5) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical Specification -for the Pump house
Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical Specification-for ceiling
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as per Technical Specification directed by the departmental authorities.
Supply & fixing of Rolling /shutter made of 80x 1.25mm machine rolled laths, interlocked together through their entire length and jointed together at the ends by end- locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work Technical Specification
Painting with synthetic Enamel paint of grade-I in two coats over a primary coat including cost of paint, labour charges etc, complete for finished item of work Technical Specification
Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work Technical Specification
Supply of CI Sluice Gate (1.20x1.80m) including all mechanical arrangements such as gearing arrangements, MS extended rods with wheel arrangements for smooth lifting & lowering and fixing at different levels as directed by Engineer-in-charge and as per Technical Specification
Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brand for rain water pipes with clamps as per Technical Specification
110 mm Dia
Providing electrification including fixures
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building as per technical specification
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete
Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply and fixing of stainless steel ladder made out of suitable sections for access from floor shab to base slab
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications.
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
COFFER DAM
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Excavation and removal of silt or silt mixed with sand in slussy condition from canal bed including disposing off the same in spoil bank or on the canal embankment for coffer dam in layers as directed etc., complete with initial lead upto 50 m and all lifts and as per Technical Specifications
FOOT BRIDGE
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Up to 5m below GL
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification.
Laying VCC M-7.5 grade cement concrete using 40 mm m/c down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Beams
Column
Walkway Slab
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing , as per technical specifications
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Supply, delivery, Erection, Testing and Commissioning of Raw Water Vertical Turbines with a duty of 1755.5 lpm against head of 91.0 mtrs with mechanical, electrical and associated accessories in proposed Intake well at Sunkesula Reservoir (50% stand by) pump sets to pump Raw Water from Intake well to WTP
Pumping System::
Clear & Raw Water Pumping Station.
Providing Raw Water Pumping system at Tungabhadra river by supply, delivery and erection of VT pump set with specifications of Head range of 88 mtrs, discharge of 105 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing . -1 Unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. C. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.-1 Set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete -1 Set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer -1 No
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare -2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station-1 Set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps-2 Sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel -1 Set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)-1.00 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.-1 Lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;-1 Set
Ring Spanner 3/16 to 1" -1 Nos
Double end spanner set 3/16" to 1"-1 Nos
Pipe Wrench 18" & 4"-2 Nos
Screw drivers 6", 10" & 12" -3 Nos
Cutting Plier 12" - 1 No
2 Kgs Hammer with Handle -1 No
Nose Plier -1 No
Flat and Half round smooth file- 2 Set
Adjustable Spanner 6"- 1 Set
Column pipe Clamps - 2 pairs
Line Shaft Clamps-1 Pair
Line rope and clamps double the weight of pump - 2 sets
Gland thghtening Spanner - 1 No
Spitter removing Spanner - 1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete-1 Set
Fire extiguisher 3Kg capacity - 2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets - 1 No
Rubber Hand Gloves -4 No
Danger Board Plates -1 No
First aid kit with chart -1 No
Shock Treatment Chart -1 No
Portable rechargeble torch light -1 No
Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc; -1 No
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,-1 Set
All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer- 1 Set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection- 1Job
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder-1 Set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 Set
Power transformer, required push buttons and MFM for each Main pump feeder-1 Set
Supply,Laying,jointing and testing of 300mm DI K9 Raw Water Pumping main from Proposed Intake well in Sunkesula Reservoir to Proposed 5.5 MLD Filtration Plant at Head Water Works in Gudur
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Excavation for roadway in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
300mm dia DI K9 class pipes
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
Sluice Valve PN 1.6
300mm dia
200mm dia sluice valves with scour arrangements
80 mm dia isolated valves for arrangement of Air Valves
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification.
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
300mm dia DI K9 class pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
300mm dia DI K9 class pipes
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
Sluice Valve PN 1.6
300mm dia
200mm dia
80 mm dia isolated valves for arrangement of Air Valves
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc.,as per Technical Specification
Laying of PCC Grade M20 - Nominal Mix using 20 mm M/C size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for Thrust Blocks -1 cum
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Valve Chamber Sluice Valve for 300 mm dia pipeline [2.30*2.00*1.85]
Valve Chamber air valve 80 mm for 300 mm pipeline [2.30*2.00*1.85]
Supply, delivery of D.I. fittings confirming to I.S.No.9523/2000 having dimensions as per table with Zinc coated externally and inside Cement Mortar lining (With finishing as per Class 13/IS 9523/2000) including cost of fittings, transportation, stacking carefully at site. The rate excluding VAT and other duties etc.,complete as per Technical specification
Supply and delivery of centrifugally cast Ductile Iron 100 mm Dia K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification.
Construction of 5.5 MLD Capacity Rapid Gravity Filtration Plant in Head Water Works at Proposed Head Water Works at Gudur
Construction & Completion of balance works of 5.5 MLD Rapid Gravity filtration plant at Head Water Works . The present Stage of Work is appended in the Tender Document
Construction & Completion of balance works of 5.5 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PHSSR 2025-26 All valves in the Filtration Plant should be compatable for operation with motorised Actuators integrated to SCADA
Construction Of 200 Kl Capacity Clear Water GLBR @ Head Water Works At Gudur
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as per technical specification.
Supply & Delivery of manhole covers and frames of HD 20- 560mm dia clear opening including all chargeswith ISI marking anywhere in A.P., F.O.R. destination including, loading, un-loading & stacking at site but excluding all taxes as per Technical specification
Stainless Steel Tubes, sections, plates, sheets & pipes of all sizes & diameters for - 304 Grade as per Technical specification.
Construction of Clear Water Pump House at Proposed HWW at Gudur
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Excavation for in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Manual Means.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification Ordinary rock (not requiring blasting) Manual means upto 3.00m depth
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification.
Laying VCC M-7.5 grade cement concrete using 40 mm M/C down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm M/C down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
a) Foundations
b) Columns (up to PlinthLevel)
c) Columns (Ground to First floor)
d) Plinth beams
e) Roof Beams
f) Roof Slab 125 th
g) Lintel
Sunshades (100 to 50mm thick)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:3) prop 20 mm thick including cost of material, labour ,curing etc. complete as per SS out side & Exterior as per Technical Specification
Cement plastering using opc in cm(1:5) prop 12 mm thick including cost of material, labour ,curing etc. complete as per Technical Specification out side & Inside
Laying insitu VCC M-7.5 grade cement concrete using 40 mm m/c down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical Specification
Supply and fixing of RCC jollys of approved design 50mm thick unit 1.00 sqm As per technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) as per Technical Specification
Supply & fixing of Rolling /shutter made of 80x 1.25mm machine rolled laths, interlocked together through their entire length and jointed together at the ends by end- locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as perTechnical Specification
Painting with synthetic Enamel paint of grade-I in two coats over a primary coat including cost of paint, labour charges etc, complete for finished item of work as per Technical Specification
Supply, delivery and fixing of 110mm dia single socket PVC pipes 4 kg/sqcm prince/Sudhakar or any ISI brand for rain water pipes with clamps as per Technical Specification
Providing electrification including fixures
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply of 9" (225mm), Light duty exhaust fan with double ball bearing and wire guard etc complete. Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DS / Orient hill air / MIIT
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges for fixing of Exhaust fan in wall with necessary connections and masonary work of making hole, finishing etc., complete
Labour charges Fixing of 20W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
Design, Supply, delivery, Erection, Testing and Commissioning of Clear Water Centrifugal Pump sets including required power supply with a duty of 3348 lpm against head of 50.0 mts with mechanical, electrical and associated accessories at proposed Pumph
Supply, delivery and erection of HSC pump set with specifications of Head range of 45 mtrs, discharge of 101 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing . -1 unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.1.00 Set
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete. 1set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1 set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer-1 No
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare -2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station -1 Set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps-2 Sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel- 1 set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)-1.00 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.-1 Lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc;-1 Set
Ring Spanner 3/16 to 1" -1 Nos
Double end spanner set 3/16" to 1"-1 Nos
Pipe Wrench 18" & 4"-2 Nos
Screw drivers 6", 10" & 12" -3 Nos
Cutting Plier 12" -1 No
2 Kgs Hammer with Handle -1.
Nose Plier -1 No
Flat and Half round smooth file- 2 Set
Adjustable Spanner 6"-1 set
Column pipe Clamps -2 pair
Line Shaft Clamps-1 Pair
Line rope and clamps double the weight of pump -2 set
Gland thghtening Spanner -1 No
Spitter removing Spanner -1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete-1 Set
Fire extiguisher 3Kg capacity - 2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets -1 No
Rubber Hand Gloves -1 No
Danger Board Plates - 4 Nos
First aid kit with chart -1 No
Shock Treatment Chart -1 No
Portable rechargeble torch light-1 No
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc;-1 No
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,-1 Set
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer-1 Set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection-1 job
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder-1 Set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 Set
Power transformer, required push buttons and MFM for each Main pump feeder-1 Set
Ssupply, delivery and fixing of 100 Kva & 250 kva transformers and construction of transformer yards at Head works at Sunkesula and at WTP at Gudur
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04044c 250KVA
1. Quantity : 1
2. Rated KVA : 250 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 95 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03460
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- Mechanical means
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
100 kva transformer
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under. Makes : As per list of recommended brands as category I. MAT-04042 a 100KVA
1. Quantity : 1
2. Rated KVA :100 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40°C in oil 45°C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X50 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- Mechanical means
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
300/250/150/100 mm dia DI K9 Clear Water Feeder Pumping mains from 200 KL SUMP at Head Water Works at Gudur to Service Reservoirs
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.
Excavation in hard rock with controlled blasting by drilling, blasting and breaking, trimming of bottom and side slopes in accordance with requirements of lines, grades and cross-sections, loading and disposal of cut rock with all lifts and leads upto 1000 m as per Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by manual Means.
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
300mm dia DI K9 class pipes
250mm dia DI K9 class pipes
150mm dia DI K9 class pipes
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
300mm dia Sluice Valves PN 1.6
250mm dia Sluice Valves PN 1.6
250mm dia Sluice Valves PN 1.6 with scour arrangements
150mm dia Sluice Valves PN 1.6 with scour arrangements
150mm dia Sluice Valves PN 1.6
Supply and Delivery of PN 1.6 D.I D/F Tamper Proof DI Flanged Single Chamber Air Release Valves confirming to IS 14845 latest amendment and Material of Construction (as per latest code) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
80mm dia
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
300mm dia DI K9 class pipes
250mm dia DI K9 class pipes
150mm dia DI K9 class pipes
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
300mm dia DI K9 class pipes
250mm dia DI K9 class pipes
150mm dia DI K9 class pipes
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
150mm dia Sluice Valves PN 1.6 with scour arrangements
150mm dia Sluice Valves PN 1.6
250mm dia Sluice Valves PN 1.6
250mm dia Sluice Valves PN 1.6 with scour arrangements
300mm dia Sluice Valves PN 1.6
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete. as per Technical specification
80mm dia
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
350mm dia [2.30*2.00*1.85 Mts]
250mm dia [2.00*2.00*1.70 Mts]
150 mm dia [1.80*1.80*1.50 mts]
80mm air valve [2.30*2.00*1.85 Mts]
Laying of Plain Cement concrete Grade M20 - Nominal Mix using 20 mm M/C size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for Thrust Blocks -1 cum
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Construction of 600 KL capacity ELSR at SC Colony with 22 Mts staging with SBC of 20 T/Sqm
Construction & Completion of balance finishing works of 600 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 Zone I at SC Colony. The present Stage of Work is appended in the Tender Document
Construction of 700 KL capacity ELSR at Thimmaguduru with 17 Mts staging with SBC of 15 T/Sqm
Construction & Completion of balance works of 700 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 Zone II at Thimmaguduru. The present Stage of Work is appended in the Tender Document
scafolding charges
Construction of 600 KL capacity ELSR at Old Police Station with 17 Mts staging with SBC of 20 T/Sqm
Construction & Completion of balance finishing works of 600 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PHSSR 2025-26 Zone III at Old Police Station. The present Stage of Work is appended in the Tender Document
Supply distrubution and fixing, installation of Flowmeters, Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoring of the bulk water supply pipelines and pumpsets raw water , clear water for SUNKESULA RESERVOIR
Instrumantation and Automation of the Pumping System:
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 150 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
250MM Dia Above Specification.
outlet of Raw Water Pumping Station at Tungabhadra river
Outlet of Clear Water Pumping main at Pumping station
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge.
Reservoir Inlet Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
150MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
150MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
150MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 600 KL Proposed ELSR at SC Colony
Inlet of 700 KL Proposed ELSR atThimma guduru
Inlet of 600 KL Proposed ELSR at Old police station
24 x 7 Water Supply :: DMA Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
200MM Dia Above Specification.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
200MM Dia Above Specification.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
200MM Dia Above Specification.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
Under 500 KL ELSR at NTR Nagar
Under 500 KL ELSR at Kakani palem
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1,2&3 under 600 KL ELSR at Old police station
AMI Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
Inlet of DMA-1, 2 & 3under 600 KL ELSR atOld police station
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Job
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Job
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer -1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station at GudurMunicipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generat-ing the reports as required by the customer at the time of commissioning -1 No
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Gudur Municipality with the above specifications.
Central Station at Kurnool Circle Level ADDANKI :
Establishment of HARDWARE for Central Control Station at Individual Circle ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Central control station where the SCADA room will be developed by the local Circle for operting & View from Service Reservoirs, DMA and AMI meter management for entire circle where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Supply and commissioning of Floor mounted/Rack server Dual Processor, 8 GB Ram x 2 Nos, Hard Disk - x 3 Nos of 1TB with raid control, Licensed OS, Mouse, keyboard and relevant accessories make of IBM/LENOVA/HP/DELL complete -1 Job
86" Interactive Display make of SENSES/ LG/ SAMSUNG/ BENQ or euilant with ethernet/HDMI/VGA supported for front end view of SCADA for monitoring, Graphical or Trends, MIS reports for the group of ULB,s or individual ULB under the circle with required cables and connectors etc., complete.-1 Job
16 port Unmanaged Switch with specifications of 220 V.AC/ 24 V.. DC., 16 No of LAN ports, Rack Mounted, Speed 100/1000 Mbps, compatable with make of CISCO/ HP/ FF/ ONV/ phoenix complete -1 No
Desktop PC Station with specification of I 7 or equilant Processor, 8 GB Ram, 512Gb SSD, Licensed OS, 24" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank for 1 Hr. back up, make of Vertiv/ EATON/ BPE/ NUMERIC /RIELLO / ENERTECH or equilant make complete -1 Nos
Fire wall application make of SOPHOS/ FORTINET or equilant make.-1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Central Unit with above specifications for Kurnool PH Circle.
Development of Softwares for Central Control Station at Circle Level :
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Central control station where the SCADA room will be developed by the Circle for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Central Unit with above specifications for Kurnool PH Division.
Construction of Clear Water SCADA Room 8.00 x 12.00 Size.
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per Technical Specification By Mechanical Means.
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying VCC M-7.5 grade cement concrete using 40 mm M/C down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour charges etc., Complete as per Technical Specification
Laying VRCC M-25 grade design mix using 20 mm M/C down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for Bed
Laying VRCC M-25 grade design mix using 20 mm M/C down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification For Side Walls of Septic Tank.
Laying VRCC M-25 grade design mix using 20 mm M/C down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
for ground floor
for first floor
Brick masonry 11.5 cm wide for super-structure on ground floor in cm (1:3) using second class traditional size bricks including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work.as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work as per Technical Specification.-for ceiling
Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges, labour charges for dressing of flooring stones etc., complete for finished item of work, but excluding the cost of conveyance of all material as per technical specification
Flooring with Non Skid Ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work, but including the cost of conveyance of all materials as per the technical specification
Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing in position ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) as per Technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) as per Technical Specification
Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work for Single leaf Door as per the technical specification
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work.Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side 20 mm wide cross PVC sheet as gap insert for top & bottom rail, panelling of 10mm(+/-)( 5mm+5mm)” thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm width stuck on the interior side of the C channel using solvent cement, complete as per direction of Engineer–in–charge, Supplyrs specification.
Providing and fixing of top hung Ventilators made of pre-painted steel (Base steel as per IS 513 of 0.80 mm thick galvanized as per IS 277 with Zinc of 120 GSM), finish painted with a polyester paint of 60-65 microns thick and section for outer frame of 80 x 45 mm, centre mullion of 80 x 60 mm, section for shutter of 52 x 25 mm x 0.6 mm thick, outer frame and mullions to have rebate for glazed shutter with a provision for guard bars/grills and the sections cut to length metre joined with corner bracket, centre mullion fixed with mullion cap, 1 No. of High grade nylon latch handle, window stopper, 2 nos. of with MS Powder coated /SS ball bearing butt Hinges provided per shutter and windows fitted with 4 mm thick plain float glass with rubber gaskets including fixing the frames in concrete/masonry wall by means of self expanding screws, Including 10 mm Square guard bars with 6” (152.4mm) pitch etc., complete for finished item of work
Providing and fixing Thermocole False ceiling in true horizontal level 600 mm x 600 mm using 15 mm/ 19 mm thick Thermocole sheet anodised Aluminium Tee sections of size 24.50 mm x 24.0 mm x 2.4 mm in grid with cross tee of size 24 x 24.5 mm at every 600 mm c/c and anodised aluminium wall angle of size 24 x 24 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick GI Wire for finished of size 600 x 600 mm including Cost &conveyance of all materials and labour charges such as cutting , fixing of standing of frame work exposing roof making complete for finished item of workas per Technical Specification
Providing electrification
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour chages
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complete for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing TPN Distribution board with IP-30 protection suitable for 3 phase ELCB / RCCB / FP Isolator as incomer and 10kA SP MCBs as outing going including internal connection and labour charges for surface / flush mounting etc., complete.BLD-ELEC-4.4.3
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and fixing of 20W, 2400 lumens, T8 not less than 1100 mm length LED retrofit tube light with aluminum anodized body, input voltage AC 220 - 260 Volts, having luminous efficacy >=100 lumens/ watt, with PF>0.9, surge protection: 2KV, THD<10%, with inbuilt driver and frosted cover CCT: 3000K-5700K, minimum CRI>70, etc., as per IS 10322 (Part 5/ Sec 1), 2012, complete with earth connection and not less than two years warranty. Makes: As per list of recommended brands as category I. a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton / Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal/Eveready// Rhino/Panasonic b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges Fixing of 40W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White
Supply of 2.0TR, 5 Star capable of delivering not less than 21600 BTU/hr and above with operating on refrigerant R-410A / R-32Makes: As per list of recommended brands as category II Makes: Blue star / Hitachi / Daikin/Lloyd (prevailing models in the market)
WS and anitery arrengements
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks etc complete as per Technical Specification
Supplying and fixing 580mm x 440mm long Orissa pan white glazed Water Closet 1st quality ISI marked confirming to IS:2556-Part-3-1981 with "P" or "S" trap, ISI marked and providing masonry seat, CC squatting plate and 10 litres capacity single flush PVC low level cistern with internal components fixed on 2 Nos. of teak wood blocks of size 76.20mm x 101.60mm using required size of nails, screws as approved by Engineer-in-charge, 15 mm nominal size CP finish brass angled stop valve screw type with internal /external threaded conforming to IS 8931, 12.70mm PVC connection with brass union nuts CP coated , 31.75mm brass plumber union, P trap or S trap of Indian W.C. shall be encased on CC (1:2:4) 150mm alround well above the joint to stop leakage at the joint etc., complete including cost and conveyance of all materials to site, cost of CC bed, labour charges and seigniorage charges, overheads & contractors profit etc., complete for finished item of work as per Technical Specification
SSupplying and fixing Indian make Flat Back Wash Hand Basin 1st quality conforming to IS:2556-Part-4:1972 of size 550mm x 400mm with 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make heavy duty complete with standard CI brackets including wooden blocks ,1 No.12.70mm PVC connection with brass union nuts CP coated , angle stop cock 12.70mm dia. first quality Indian make heavy duty, 30mm dia. PVC flexible waste pipe 914.4mm length of 1st quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit for finished item of work as per Technical Specification
Supplying and fixing white glazed flat back Bowl urinals of size 440 mm x 265 mm x 315 mm with integral flushing rim fixed with screws complete Indian make (HSW/Parry/Neycer) conforming to IS:2556-1995 as approved by Engineer-in-charge, including supply and fixing 12.7mm PVC connection with brass plumber union nuts CP coated, 12.70mm push cock 1st quality of approved make , 30mm dia PVC flexible waste pipe of 914.4 mm length of Ist quality including cost and conveyance of all materials to site, labour charges , overheads & contractors profit complete for finished item of work as per Technical Specification for all floors
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg
Supply and Fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines and inlet
20 mm dia nominal bore -from jn for of individual lines to toilets
15 mm dia nominal bore -for internal
Supply and fixing of GI & GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality as per Technical Specification
Laying of HDPE PE 100/ 6 KSC Water Supply Distribution Pipelines
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Mechanical Means.as per Appended Technical Specification
Excavation in in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with all lifts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections Appended Technical Specification
Earthwork in excavation for Pipe Line as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material by Manual Means.
Supply and Delivery of HDPE PE-100 6 KSC Pipes conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
250mm dia HDPE 6KSC PE 100
200mm dia HDPE 6KSC PE 100
160mm dia HDPE 6KSC PE 100
110mm dia HDPE 6KSC PE 100
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
250mm dia HDPE 6KSC PE 100
200mm dia HDPE 6KSC PE 100
160mm dia HDPE 6KSC PE 100
110mm dia HDPE 6KSC PE 100
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
BENDS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
END CAPS
110 OD HDPE Pipes
160 OD HDPE Pipes
200 OD HDPE Pipes
250 OD HDPE Pipes
REDUCERS
110 OD to 160 OD HDPE Pipes
OD 110mm x 125mm
OD 125mm x 140mm
OD 140mm x 160mm
160 OD to 200 OD HDPE Pipes
OD 160mm x 180mm
OD 180mm x 200mm
160 OD to 250 OD HDPE Pipes
OD 200mm x 225mm
OD 225mm x 250mm
250 OD HDPE Pipes
OD 250mm x 280mm
OD 280mm x 315mm
Supply and delivery of PN 1.6 D.I D/F "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) confirming to IS 14846 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge
For Sluice Valves- PN 1.6
100mm dia D/F sluice valves P.N 1.6 Type
150mm dia D/F sluice valves P.N 1.6 Type
200 mm dia D/F sluice valves P.N 1.6 Type
100mm dia Isolated Sluice Valves with scour Arrangements
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
100mm dia D/F sluice valves P.N 1.6 Type
150mm dia D/F sluice valves P.N 1.6 Type
200 mm dia D/F sluice valves P.N 1.6 Type
100mm dia Isolated Sluice Valves with scour Arrangements
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk Sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
Valve Chamber for 200 &250mm dia [2.00*2.00*.170 Mts]
Valve Chamber for 100 & 160mm dia [1.80*1.80*1.50 Mts]
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/Is 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Cutting open C.C. Road surface including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Collection, Supply and filling of sand to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete for road restoration
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VCC M-30 grade cement concrete using 20mm M/C metal size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Providing Domestic House Service Connections
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
Providing house service connections at house holds side in earthern roads
Providing house service connections at other side in earthern roads
Providing house service connections at other side in BT &CC roads
Providing house service connections at HH side in BT &CC roads
Environmental and Social Mitigation Plan for Gudur Nagara Panchayat
Monitoring Costs : Construction Phase (Two years)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
YERRAGUNTLA NAGARA PANCHAYATH
Construction of 10 m dia Intake well cum Pump House in Gandikota Reservoir, approach bridge of 40 mts length with including formation of 80 mts length coffer dam.
Providing embankment for construction of intake well in Gandikota Reservoir and filling using impervious soil in layers of 25.00 cm and compacting vibratory earth rammers including cost of all materials, machinery, labour, picking previous layer, spreading soil in layer, breaking clods, watering etc., complete and as per Technical specification
Earthwork in excavation by Mechanical means in all Types of soils for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork in excavation by Mechanical means in all Types of soils for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Filling foundation with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Raft Slab
Side Walls
Sidewalls of intake well from 188.000 mts to 193.000
Sidewalls of intake well from 193.000 mts to 196.000
Sidewalls from 196.000 mts to 199.00
Sidewalls from 199.00 mts to 202.000
Sidewalls from 202.000 mts to 205.000
Sidewalls from 205.000 mts to 208.00
Sidewalls from 208.000 mts to 211.000
Sidewalls from 211.000 mts to 214.000
Sidewalls from 214.000 mts to 215.000
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
for Pump house Columns
Roof Beams
Floor Slab 0.30 m thick
Lintel Beams
Roof beams
Roof slab 0.150 m thick
Sunshade of 0.60mts wide and thickness of .075mts at fixed end and 0.05mts.at free end
Brick masonary in CM (1:6) using 2nd class bricks of size 23 x 11 x 7cms. Cost including cost and conveyance of all materials at site, labour charges for curing etc., complete as per S.S
Ground floor
Parapet wall
Supply and fixing of 40mm thick pre-cast Cement Jali of approved design including cost and conveyance to work spot and all labour charges for fixing in position etc.complete as per S.S
Plastering with CM (1:5) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete for finished item of work and as per Technical Specification
Ground floor
Parapet wall
Providing impervious coat with C.M. (1:3) 20 mm thick laid when the roof slab is green with water proof compound @ 1kg/bag of cement finished smooth with a floating coat of neat cement including cost & conveyance of all materials etc complete for finished item of work and as per Technical Specification
for Roof slab top
Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical Specification for ceiling
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as per Technical Specification and directed by the departmental authorities.
Painting two coats with synthetic enamel paint over a base coat of red led. The rate includeds cost and conveyance of all materilas at site, labour charges, scaffolding charges etc., complete as as per Technical Specification and directed by the departmental authorities
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical Specification-1.35x1.20m size
Bailing out of water with oil engine, driven pumpset including hire charges, fuel charges and wages of driver and helper etc., complete as per the directions of departmental authorities
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification -350mm dia
Supply and delivery of 350mm dia. 2.0m. long centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends of K-9 Class confirming to specification No.IS 8329/2000 of standard working lengths with cement lining inside the pipe, out side Zinc Coating including cost of Pipe, VAT and other duties. The rate including transportation and conveyance to work spot and stacking at site etc., complete as per Technical Specification and as directed by the departmental authorities.
Supply and delivery of SS/C.I/M.S 12.00m. long operating handle with rod & wheel for operation of D.I. Sluice valve inside the intake well as per the actuals and as directed by the departmental authorities.
Supply and erection of MS Gantry girder 5T capacity as per the approved designs and drawings and as per Technical Specification
Supply and fixing of Stain less steel ladder made out of suitable sections for access from floor slab to Base slab as per Technical Specification
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Construction of Approach Bridge for intake well in Gandikota Reservoir 40.00 m long
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification- Mechanical means
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying insitu VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footing
Columns
b) For Carriage Slab Beams
c) For Carriage Slab 0.20m thick
Construction of R.C.C. railing of M 25 grade in cast-in-situ with 20 mm nominal size aggregate, true to line and grade, tolerance of vertical railing post not to exceed 1 in 500, centre-to-centre spacing between vertical posts not to exceed 2000 mm as per drawing and technical specifications including cost of necessary reinforcement etc.complete as per Technical Specification
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Painting two coats with snowcem paint of approved colour including cost of primary coat with white cement. The rate includes cost and conveyance of all materials at site, labour charges, scaffolding charges etc., complete as per Technical Specification and as directed by the departmental authorities.
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Providing Raw Water Pumping system at Gandikota reservoier by supply, delivery and erection of VT pump set including cost of VFD Control Panels with specifications of Head range of 50 mtrs, discharge of 188 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Providing Raw Water Pumping system at Gandikota reservoier by supply, delivery and erection of VT pump set with specifications of Head range of 50 mtrs, discharge of 188 M3/Hr for Raw Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above VT pump set with Lowering of the pump with necessary grider arrangement, lowering of Column pipes and Shafts, flanges fixing with suitable packings and coupling to true to allignment, pump foot base erection on Gridrs, fixing of motor, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works if required, given electrical connections and testing . -1 Unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. C. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header.- 1 set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete -1 set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer -1 No
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare -2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station -1 Set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps-2 Sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel -1 Set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination)-1.00 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete.-1 Lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc-1 set
Ring Spanner 3/16 to 1" -1 Nos
Double end spanner set 3/16" to 1"-1 Nos
Pipe Wrench 18" & 4"-2 Nos
Screw drivers 6", 10" & 12" -3 Nos
Cutting Plier 12" - 1 No
2 Kgs Hammer with Handle -1 No
Nose Plier -1 No
Flat and Half round smooth file- 2 Set
Adjustable Spanner 6"- 1 Set
Column pipe Clamps - 2 pairs
Line Shaft Clamps-1 Pair
Line rope and clamps double the weight of pump - 2 sets
Gland thghtening Spanner - 1 No
Spitter removing Spanner - 1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete-1 Set
Fire extiguisher 3Kg capacity - 2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets - 1 No
Rubber Hand Gloves -4 No
Danger Board Plates -1 No
First aid kit with chart - 1No
Shock Treatment Chart - 1No
Portable rechargeble torch light-1 No
Supply and delivery of indigeneous make 500 V.. insulation tested a portable type technometer and megger etc;-1 No
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,-1 Set
All Civil Works Such as anchor Blocks, Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer- 1 Set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection-1 job
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder-1 Set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 Set
Power transformer, required push buttons and MFM for each Main pump feeder-1 Set
Supply, delivery and laying of 400 mm dia DIK9 pumping Main from Intake well in Gandikota Reservoir to WTP
Cutting open B.T. road surface (as well as asphalt concrete upto 75 mm thick) including water bound macadam including stacking of excavated materials for pipe line trench work including all labor charges etc., complete and as per Technical Specification
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron 400 mm Dia DI K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification-400mm
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification-400
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation, taxes etc. complete as per Technical Specification.
400 mm DI K9 1M D/F Pipe
250 mm DI K9 1M D/F Pipe
100 mm DI K9 1M D/F Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
250 mm dia
400mm dia
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., complete and as per Technical Specification
300 mm dia
250 mm dia
100 mm dia
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification
400 mm dia Sluice Valve 1.6
250 mm dia Scour Valve 1.6
100 mm dia Isolated Valves 1.6
Supply and delivery of PN 1.6 DI/DF Tamper Proof DI Flanged Single Chamber Air Release Valves conforming to IS 14845 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification S100mm dia
Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return Valves) conforming to IS- 5312 (Pts-1&2) (with amendments up to date, if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon steel; Gaskets with Rubber; Hinges with Cast steeland including cost and conveyance and as per Technical Specification. 400mm dia (PN 1.60)
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
400 mm dia
250 mm dia
100 mm dia
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per the Technical Specification 100mm Dia
Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mm HBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete.
Laying insitu RCC M-20 grade Nomin mix using 20 mm down size m/c HBG approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification .Nominal mix for Anchor Blocks PCC M20
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab and as per technical specification
400mm dia valve [2.20*2.20*1.90 Mts]
250 mm dia [2.00*2.00*1.70 Mts]
100 mm dia [1.80*1.80*1.50 Mts]
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. for Road Restoration
Design and Construction of 8 MLD Rapid Gravity Filtration Plant including all civil, mechanical and electrical works using Gravel & sand as filter media, compatible duly following relevant CHPEEO Manual & IS codes in the design of plant components taking in to consideration 25% overloading including chlorine contact tank and including trial running for 90 days etc.,as per the appended Technical Specification of the tender document and also as per specifications of PH SSR 2025-26. All valves in the Filtration Plant should be compatable for operation with motorized Actuators integrated to SCADA
Recyling Unit at WTP
Construction of 100 KL Collecting Sump at Wtp
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width Ordinary rock (not requiring blasting) Mechanical Means Upto 3 m depth
Plain cement concrete in (1:4:8) prop using 40 mm nominal size hard broken machine crushed granite metal as per SS including cost and conveyance of all materials, seignarage, sales tax and labour charges such as mixing concrete, laying, tamping, curing all operational, incidental charges etc., complete as per SS for finished item of work for building foundation concrete.
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Extra Columns Footings
Sidewalls of Sump 250mm th
Columns
Ring Beams
Roof slab 200mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work as per technical Specification
M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint etc compelte for finished item of work as per technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coat (All Colours) including cost of primary coat as per technical Specification
Construction of 200 KL Settling Sump at Wtp
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, removal of stumps and other deleterious material and disposal upto a lead of 50 m, etc complete for pipe line trenches & building foundations where depth is less than 1.50 times the width Ordinary rock (not requiring blasting) Mechanical Means Upto 3 m depth
Plain cement concrete in (1:4:8) prop using 40 mm nominal size hard broken machine crushed granite metal as per SS including cost and conveyance of all materials, seignarage, sales tax and labour charges such as mixing concrete, laying, tamping, curing all operational, incidental charges etc., complete as per SS for finished item of work for building foundation concrete.
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Floor Slab
Extra Columns Footings
Sidewalls of Sump 250mm th
Columns
Ring Beams
Roof slab 200mm thick
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
M.S railing with 50mm dia M.S pipe for vertical posts at 900mm c/c upto height of 0.75mts with 2Nos of horizontal pipes of 25mm thick including fabricatioin, fixing in position and painting with enamel paint etc compelte for finished item of work as per technical Specification
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coat (All Colours) including cost of primary coat as per technical Specification
Laying of 200 mm dia Pumping Main from Sump to Aerator
Earthwork in excavation by mechanical means in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -mechanical
Earthwork in excavation by manually in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in ordinary rock blasting not required for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification
Earthwork excavation in Hard rock and boulders more than 3 Cum in size for pipeline trenches without blasting for pipeline trenches etc., and as per specification drawing and as directed by departmental officers and to protecting the existing walls and other structures etc., so as not to disturb the existing utility services existing water supply lines, sewers, telephone,power cables/ducts, storm water drains, traffic signals ,etc., during the laying of pipe line taking all precautionary measures in the restricted areas with the initial lead of 50mts and intial lift of 3m for pipeline trenches for laying of water main taking all precautionary measures in the restricted areas such as urban areas including divertion of traffic including all incidental and operational charges etc., complete
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification 200mm dia
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification-200mm dia
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) but including all sundries filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification -200mm dia
Provision for 4 No 6 Kw Pumpsets Pump back wash water from sump to Aerator
Supply ,delivery,and erection of 4 Nos of Centrifugal pumpsets of 6 KW capacity vertical turbine pump sets having discharge of 9 lps againt head of 16 mts with combined efficiency of 60% to pump Back Wash Water from Sump to 10.0MLD WTP with 100% stand by of standard make including suction, and delivery connections , Panel boards, cables, earthing arrangements, Non return valves, Butter fly valves , Providing thrust blocks, M.S specials and pipes connection upto puming main, , all taxes and duties, and all labour charges etc., complete including delivery connections upto pumping main.
Sludge Ponds
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification Mechincal Means
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification by Manual means
Excavation in Hard Rock (blasting prohibited) :Excavation for roadway in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in tippers and disposal with initial lift of 3 mts and lead upto 1000 metres, trimming bottom and side slopes in accordance with requirements of lines, grades and cross- sections as per Technical Specification
Laying of VCC M -7.5 using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete as per the Technical SPecification
RCC M- 30 Desgin mix (Cement:fine aggregate: coarse aggregate) corresponding to Table 9 of IS 456 using 20mm size graded machine crushed hard granite metal (coarse aggregate) from approved quarry including cost and conveyance of all materials like cement, fine aggregate (sand) coarse aggregate, water etc., to site and including Seigniorage charges, sales & other taxes on all materials including all operational, incidental and labour charges such as machine mixing, laying concrete, curing etc.,complete but excluding cost of steel and its fabrication charges for finished item of work including centering, shuttering.
Sidewall
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Plastering with CM (1:3) 12mm thick including cost and conveyance of all materials at site labour charges for finishing and curing etc., complete as per Technical Specification
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Construction of 220 Kl clear water sump at Head works
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD / 304 MORTH for foundations upto 3.00m depth -Manual means
upto 3m depth
3m to 6m depth
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying of VCC M-7.5 using 40 mm graded HBG m/c metal and OPC coarse and fine aggregate including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per the Technical Specification
Laying insitu VRCC M-30 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC Cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding reinforcement etc., complete and as per Technical Specification
Raft slab
For side walls circular 0.30m thick initial height 3.00 m below GL
For side walls circular 0.25 m thick above GL
Columns0.30 x 0.30 ,
Roof beams
Roof slab 0.20m thick
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work as per technical Specification
Colour washing two coats Using snowcem including cost and conveyance of all labour charges etc.,complete as per technical Specification (in and out side)
Supply and delivery and fixing in position M S gril of any design including all fabrication and all fixing charges etc compalete as per ss and as directed by the dept authorities as per Technical Specification
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of 7.5mx 12 m Clear water pump house at Head water Works
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Providing PCC (1:3:6) using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing , vibration,laying in position, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mmm/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
RCC Walls
Lintel beams
Roof Beams
Roof slab - 150 mm
Sunshades 0.60m wide, 0.075m at fixed end and 0.05m at free end
Brick Masonry in CM (1:5) for 230mm thick with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work as per the Technical Specification.
Ground floor
Parapet wall
Plastering with CM (1:4), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification-inside and outside
Ground floor
Parapet wall
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- ceiling
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface including labour curing for finished item of work and as per Technical Specification
Colour washing two coats Using snowcem over the primery coat conveyance of all labour charges etc., complete as per Technical Specification (in and out side)
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical specification Door 1.20x2.10m
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work as per Technical specificationWindows 1.50x1.20m
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and fixing of precast RCC Jollys 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Providing 3 Nos of 30 KW capacity Centrifugal pump sets including cost of VFD Control Panels having discharge of each 50 lps againt head of 42 mts with combined efficiency of 75% to pump Clear Water from Clear Water Sump to GLBR on Hillock (2 Working + 1 Strandby)
Supply, delivery and erection of HSC pump set with specifications of Head range of 42 mtrs, discharge of 180 M3/Hr for Clear Water (2 Working + 1 Strandby) Pumping station with the following specifications and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Erection of pump: Errection, testing and commissioning of above HSC pump set with construction of suitable size concrete base with VRCC M 30 grade, motor and pump unit erected on channel base, lowering on CC base, alignment with sutable dial guage equipment, grouting of foundation bolts, CC plingth finishing with masionery works, given electrical connections and testing . 1 Unit
Valves & Accessories for Pipe lines at Pump House: A. Arranging of Non return & Gate/Butterfly valve and SS Expansion bellow for delivery lines of individual pump. B. Arranging of Gate/Butterfly valve & Expansion Bellow for Suction line where ever the pumping system under possitive suction. C. Arranging of Gate/Butterfly valve & Expansion Bellow on common header at out side of the pump house. D. fixing of suitable dia Vacume and pressure guages with Gliseron filled by providing safety cock on Suction, Individual Pump Delivery and common header. 1set
Vaccume Pumping: Suitable size of Vaccume pump set with 100% Standby and connected Vaccume pipe lines with suitable GI line and providing heavy duty gate valves for individual pump. Necessary Electrical connections, Suitable coolent tank as required with necessary civil works etc., complete. 1set
Control MCC & PCC : Fabrication, supply, fixing, errection, termination, testing and commissioning of indoor type, dust and weather proof MCC & PCC Panel fabricating with 16 SWG CR sheet, making individual compartments for components, making internal wiring with suitable al busbars (Concider 0.9 Amp per Sq.MM area) and copper wires for internal wirings as per IE rules, internal and external surface coating with epoxy powder coating with seven tank process and fixing following components complete 1set
Suitable capacity of MCCB with- 55 kA - 3 Pole, MPR, spreader links and ROM set for Incomer 1 Nos
Suitable Capacity of MCCB 36KA 4P MPR, spreader links and ROM set for SCADA & Spare 2 Nos
Suitable Capacity of MCCB 36KA 3P MPR, spreader links and ROM set with capacitor bank with Capacitor contactor and Time delay relay to maintan greaterthan 0.9 PF while full runnig of the Pumping station 1set
Providing DOL feeder with MPCB, CONTACTOR, add on blocks and other accessories for Vacuum and dewatering pumps 2 sets
Multifunction metering set with Analog voltmeter and other necessary indication lamps and necessary MCB's for control wiring including Power transformer etc., complete for total control panel 1 set
Supply, laying, termination and testing suitable capacity of 1.0 core PVC sheeted, Copper flexible cable (Concider 1.6 Amps per Sq.MM) for in coming power to Drive control centre and to motors, laying with suitable size of cable trays/ PVC conduits according to site condition to fixing wall on groung with necessary angle frame work, laying of cable, tiening, both ends crimping, termination and testing (For laying the erath continouty of 1 run from VFD to Motor should be equal to other conductors to motor termination) 1 Lot
Providing earthing to all control panels, Pump motors and all electrical equipment as per the IE rules with necessary earth pits, Copper/GI earth flats etc., complete. 1 lot
Supply and delivery of necessary suitable errection tools of reputed make mounted on polished teak wood board including cost of materials and all taxes and duties etc; 1 set
Ring Spanner 3/16 to 1" -1 No
Double end spanner set 3/16" to 1" -1 No
Pipe Wrench 18" & 4"- 2 no
Screw drivers 6", 10" & 12" -3 No
Cutting Plier 12" -1 No
2 Kgs Hammer with Handle -1 No
Nose Plier -1 No
Flat and Half round smooth file -2 No
Adjustable Spanner 6" -1 No
Column pipe Clamps -2 No
Line Shaft Clamps -1 No
Line rope and clamps double the weight of pump -2 No
Gland thghtening Spanner -1 No
Spitter removing Spanner -1 No
Supply and delivery of necessary safety equipments as per IE Rules including cost of materials and all taxes and duties etc; complete 1 ste
Fire extiguisher 3Kg capacity -2 Nos
Rubber Mat 6" x 4" - 2 Nos
Fire Buckets with stand and three buckets - 1 Nos
Rubber Hand Gloves - 1 Nos
Danger Board Plates - 4 Nos
First aid kit with chart - 1 Nos
Shock Treatment Chart - 1 Nos
Portable rechargeble torch light - 1 Nos
Supply and delivery of indigeneous make 500V insulation tested a portable type technometer and megger etc; - 1 Nos
Supply, delivery and erection of suitable capacity (Capacity of the Crane should be two times than the total weight of each pump unit) girder gantry arrangements to move and lift the installations of the pump house one way with required MS ISMB of standard make, including the required MS ISMC, MS angular iron, travelling trolley and chain pulley block with chains of suitable capacity for lifting and moving arrangements to length of 10.00 m rate is inclusive of the cost of materials, labour charges, site welding etc.,1set
All Civil Works Such as anchor Blocks ,Thrust Blocks, Platform for Pannel Board and Cable trench etc Complete as directed by the Field Engineer 1 set
Testing and maintanance of the complete equipment covered and trial run for 30 days at 8 hours per day after completion of errection 1 Job
Supply, delivery and erection of VFD Control Panels for Pump sets with the following specifications as below and the charges including all cost, convayance, tools, tackles, labor etc., complete and excluding cost of GST and as per the SS and as directed by the department officer.
Suitable capacity of three Pole SFU WITH 1NO+1NC ADD ON BLOCKS with semi conductor fuses for Main pump feeder -1 set
Suitable capacity of AC3 duty, TP, POWER CONTACTOR WITH 2NO+2NC ADD ON BLOCKS (COIL 230V AC) for Main pump feeder -1 set
Power transformer, required push buttons and MFM for each Main pump feeder -1 set
Supply, delivery, laying, jointing and testing of 400 mm dia DI K9 Pumping main from Clear Water Sump at WTP To Proposed GLBR on Hillock
Earthwork excavation by machinery and depositing on the bank in all types of soils like black cotton soil, red earth, and ordinary gravel, hard gravelly soils, mixture of gravel and soft disintegrated rock, like shelves,stonematrix, removable by pickaxes and crow bars for pipeline trenches and as per specification, drawings and as directed by the departmental officer with an initial lead of 50 M and with all lifts and delifts for pipe line trenches including all incidental and operational charges etc., complete and as per Technical specification
Earth work excavation in all soils up to SDR & stone matrix by machinery as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and back filling in trenches with excavated suitable material as per Technical Specification up to initial lift of 3.0ms. For Pipe line trenches.
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-9 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification 400 mm DI K9
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification 400 mm DI K9
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including all sundries ,cost of rubber Gasket ,filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification 400 mm DI K9
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation, taxes etc. complete as per Technical Specification.
400 mm dia 1m Long
250 mm dia 1m Long
100 mm dia 1m Long
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., complete and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification
400 mm dia Sluice Valve 1.6
250 mm Scour Valve
100 mm dia Isolated Valves 1.6
Supply and delivery of PN 100mm dia 1.6 DI/DF Tamper Proof DI Flanged Single Chamber Air Release Valves conforming to IS 14845 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification
Supply and delivery of DI D/F Swing Check Valves Slanted/Straight seated with metallic, corrosion proof and wear resistant seat faces resilient seat, Body and Disc of ductile cast iron GGG 40/SG Iron 420/12 or equivalent grade as per IS 3896(part2)-1985 and subsequent revisions. All the inside and outside of the body is to be coated with double coating of epoxy liquid. Drilled as per IS:1538. Specification and Dimensions as per I.S 5312 or equivalent codes.-250mm (PN 1.60 MPa)
Labour charges for lowering and keeping in position of DI. Sluice valves, reflux valves and scour valves as per Technical specification
400mm dia
250 mm Scour Valve
100 mm dia Isolated Valves 1.6
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per the Technical Specification 100mm Dia
Laying RCC M-20 grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification for Anchor Blocks
Laying RCC M-20 grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.Nominal mix for Anchor Blocks PCC M20
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) / Mild steel (MS) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying including sales and other taxes on all materials etc., complete for finished item of work
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab and as per technical specification
400mm dia valve [2.20*2.20*1.90 Mts]
300mm dia ( 2.10*2.10*1.80 Mts)
250 mm dia [2.00*2.00*1.70 Mts]
100 mm dia [1.80*1.80*1.50 Mts]
100 mm dia Isolated Valves 2.5 [2.30*2.00*1.85 Mts]
Supply, delivery, laying, jointing and testing of 500 mm/350 mm /250 mm/200 mmdia DI K7 Gravity Feeder main from GLBR near Head Works to Different 4 Zone ELSRs
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in ordinary rock blasting not required for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification.
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Supply and delivery of centrifugally cast (spun) Ductile Iron K-7 pressure pipes for water with socket spigot ends conforming to IS: 8329/2000 suitable for push-on-joint (rubber gasket d jointing) with cement mortar lining inside the pipes with outside zinc coating including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
500mm dia. DI K7
300mm dia. DI K7
250mm dia. gravity Main DI K7
200mm dia. gravity Main DI K7
150mm dia. gravity Main DI K7
100mm dia. gravity Main DI K7
Lowering D.I. Pipes (all classes) and specials (fittings) with s/s ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
500 mm DI K7
300 mm DI K7
250 mm DI K7
200 mm DI K7
150 mm DI K7
100 mm DI K7
Jointing D.I. pipes and fittings with rubber gasket (push-on-joint) including all sundries ,cost of Rubber Gaskets filling with water, with a water lead up to 500m and testing to required pressure, etc. complete and as per Technical Specification
500 mm dia DI K7
300 mm dia DI K7
250 mm dia DI K7
200 mm dia DI K7
150 mm dia DI K7
100 mm dia DI K7
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
500 mm DI K9 1M D/F Pipe
150 mm DI K9 1M D/F Pipe
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Lowering D.I. Pipes (all classes) and specials (fittings) with flanged ends carefully into trenches and laying them true to alignment and gradient including all sundries etc., complete and as per Technical Specification
250 mm 30 to 60 Bends
200 mm x 100 mm Air tees
200 mm 30 to 60 Bends
Jointing the D.I. Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500 m and testing to required pressure etc., comp as per BIS No.3114/85 and as per Technical Specification
a) For Sluice valve of 500mm dia - PN1.6
B) For Scour valve of 150mm dia - PN1.6
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification
Scour valve of 150mm dia - PN1.6
For Isolated 100mm dia - PN1.6
Supply and delivery of PN 1.6 DI/DF Tamper Proof DI Flanged Single Chamber Air Release Valves conforming to IS 14845 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification 100mm Dia
Supply and delivery of PN 1.60 Mpa D.I D/F Butterfly Valves confirming to IS 13095 latest amendment and Material of Construction (as per latest codes) as per Technical Specification of the Tender Document including cost and conveyance and stacking as per standards and as directed by Engineer-in-charge.500mm
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
500mm dia
150mm dia
100 mm dia
Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per the Technical Specification 100mm Dia
Barricading, hoarding, lighting and diversion of traffic, providing caution boards and watching for water supply and sewerage works including all labour charges, incidental and operational charges etc., complete.as per the Technical Specifications
Construction of R.C.C. thrust blocks using using VRCC M20 Gr. nominal mix using 20mm HBG metal from approved quarry including cost and conveyance of all materials at site, seignorage charges, labour charges for machine mixing, laying, vibrating including centering charges but excluding cost of steel for reinforcement and its fabrication including curing etc., complete.as per technical Specification
Canal crossings by providing major bridges
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification {mechnical)
Laying VCC M-7.5 grade cement concrete using 40mm graded metal (2/3 rd) & 20mm graded nominal size (1/3rd) HBG machine crushed metal (1 Cement : 3 Sand : 6 Coarse aggregate) including cost and conveyance of all materials, seignorage charges, labour charges, mixing charges, consolidation, levelling, centering charges etc., complete with skin reiforcement as per standard specifications for finsished item of work but excluding cost of reinforcement , fabrication charges including VAT and labour complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20m/c mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for canal crossing works
Foundation
Rectangular Portion Pier
Triangular projection Pier
Abutment
Slab 200 mm thick
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Mild Steel (MS) Steel bars (Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,,0.10m Thk sand,0.10m Thk Bed, 0.10m Thk Raft ,Side wall 0.20m,0.15m Thk cover slab and as per technical specification
500 mm dia [2.30*2.30*2.00 Mts]
150 mm dia [1.80*1.80*1.50 Mts]
100 mm dia [2.30*2.00*1.85 Mts]
Cutting and open of B.T. Road surface (as well as asphalt concrete upto 75mm thick) including water bound macadam including stacking of excavated materials for lying of pipe lines as per the ditections of the departmental authorities.
Cutting and open of C.C. Road surface including stacking of excavated materials for lying of pipe lines as per the ditections of the departmental authorities.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work Labour charges for fixing Kinetic Air Valves with isolating Sluice valves, Double Air valves/ Air Cushion valve excluding cost of jointing materials such as bolts, nuts and rubber insertions etc., complete as per the Technical Specification
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause.
Road crossing/Canal crossing by adoptingtrenchless technology tunneling work through specialized pipejacking method by erecting the equipment to true to the alignment and gradient, by hydraulic pipe jacking technique complete including tunneling, excavation in all types of soils including hard rock and construction of RCC chambers suitable to casing pipe pits, and conveyance charges of machinery and other required materials but excluding cost of encasing pipe, in co-ordination with the concerned authorities as per approved drawings and directed by the Engineer-in – charge
Supply and Delivery of M.S Pipes Conforming to IS 3589/2001 including in lining with Cement motor(1:2)12mm thick using 4 numbers of 6mm dia M.S.Rings at each end of the pipe and Out coating cement motor(1:3)30mm thick by shorcreting or Guniting duly providing wire mesh of size 50x50x3mm including cost of all materials,Labour charges, transportation to anywhere in AP, but including taxes & duties, etc. 800mm dia 12mm thick
Cost of Laying, Jointing, Hydrostatic filed test pressure, including cost of site welding, jointing materials and cost of transportation of water including emptying pipe line after completion of filed testing
Construction of 615 Kl clear water GLBR on Hillock
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm M/Cdown size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mmM/C down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Base Slab
Side wall
Columns
Ring Beam
Roof Slab 200 mm Thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Colour washing two coats Using snowcem including cost and conveyance of all labour charges etc.,complete as per the technical specification (in and out side)
Supply and delivery and fixing in position M S gril of any design including all fabrication and all fixing charges etc compalete as per ss and as directed by the dept authorities as per the technical specification
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical specification
Lowering, keeping in position and fixing DI sluice valves (with cap / with hand wheel & reflex valves) including all labor charges and incidental charges and as per Technical Specification
Jointing the DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500m and testing to required pressure complete as per the technical specification
400 mm dia flanged joints
150mm dia flanged joints
350mm dia near valves
150mm dia near valves
Construction of 750 KL ELSR at Zone-1
Design and Construction of 750 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PH SSR 2025-26
Construction of 1000 KL ELSR at Zone-2
Design and Construction of 1000 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PH SSR 2025-26 (Zone - 2)
Construction of 600 KL ELSR at Zone-3
Design and Construction of 600 KL Capacity M30 Grade desing mix VRCC ELSR 17.00Mts Staging raft foundation with wind presssure not less than 250 Kg/Sq.m and seisimic zone as per IS code 1893 latest amendment including doglegged staircase, DI inlet/outlet/Scour/overflow arrangements, DI valves and specials, Valve pits, construciton of approved design compound wall not less than 150 Rmt and construction of approved desing watchman quarters not less than 40 Sq.m and as per the appended Technical Specification of the Tender Document and also as per specifications of PH SSR 2025-26 (Zone -3)
Supply, delivery and erection of 160 KVA transformer and dedicated feeder main with all accessories near raw water intake well in Gandikota reservoir.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04043b 160KVA
1. Quantity : 1
2. Rated KVA : 160 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
315KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X50 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b
Transformer yard
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by Mechanical Means.
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying insitu VRCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by the Departmental Authorities and as per the technical specification (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work as per the technical specification for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Paymets to APSPDCL towards ICD Charges (Initial Caution Deposit)
Payment to APSPDCL towards Developmental Charges
Supply, delivery and erection of 315 KVA transformer and dedicated feeder main with all accessories near WTP in Head Works with Transformer yard 15.00x12.00m
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
A) Earth Electrodes
B) 20mm x 3mm Copper Flat(0.529Kgs/1Mtr) MAT 04146
C) Epoxy insulators
D) No.'8' SWG Copper wire. MAT 04141
Supply and Transportation of ISI marked copper wound Transformers 11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding 7.5%of the maximum total loss values for 11 KV as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10% to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993 complete and as per the following continuous rating. Makes : As per list of recommended brands as category I. MAT-04045D 315 KVA
1. Quantity : 1
2. Rated KVA : 315 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40?C in oil 45?C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
315KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X50 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03457b
Transformer yard
Earth work in excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by Mechanical Means.
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per ss
Laying VCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying insitu VRCC M-20 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Column footings
Columns
Plinth beam
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by the Departmental Authorities and as per the technical specification (Posts and struts of wood, concrete, steel, etc.) and straining bolts shall be paid for separately).
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work for gates and grills.
Supply and filling with Cost of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Paymets to APSPDCL towards ICD Charges (Initial caution Deposits)
Payment to APSPDCL towards Developmental Charges
Construction of staff Quarters at proposed intake well
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying of VRCC M30 Nominal Mix using 20 mm graded HBG m/c metal and OPC Cement, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing and as per Techncial Specification
For1st footing
Columns (BGL)
Plinth beam
Lintle beams
Roof Beams
Roof slab 150 mm
Sunshades
Roft slab
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification -GF
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification 1st floor
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.GF
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.1st floor
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Supply delivary and fixing RCC Jalles 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing etc complete as per the technical specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specification 1.2x1.2
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specification
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work as per the technical specification.
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per the technical specification.
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe415 / Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Providing PCC (1:3:6) using 40 mm graded SS 5 HBG m/c metal and OPC coarse and fine aggregate confirming to IS 383 including cost and conveyance of all materials and labour charges, machine mixing, vibration, laying in position, curing etc., complete as per Technical Specification
Supply,delivery and fixing of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat as per approved design by the department including cost and coveyance and all labour charges for fixing for finihsed item of work and as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification Rain water pipes
Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface etc
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with "P" or "S" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size
Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg
Supply and Fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI & GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--mechincal means upto 3m depth for foundations
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:5) prop 12 mm thick including cost of material, labour ,curing etc. complete as per the technical specificationout side & inside
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specificationcover slabs 0.15 thk
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (FE 415/Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of staff Quarters at proposed WTP (Head Water Works)
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Filling foundation wells with sand in layers and compacting by watering, ramming as directed including cost of all materials, machinery, labour etc., complete and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying of VRCC M30 Nominal Mix using 20 mm graded HBG m/c metal and OPC Cement, coarse and fine aggregates conforming to IS:383 including cost & conveyance of all materials, labour charges, machine mixing, vibration, centering, laying in position, curing and as per Techncial Specification
For1st footing
Columns (BGL)
Plinth beam
Lintle beams
Roof Beams
Roof slab 150 mm
Sunshades
Roft slab
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification -GF
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification 1st floor
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.GF
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.1st floor
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification
Providing impervious coat to exposed RCC roof slab surface with CM(1:3), 20mm thick with 1kg of water proof compound per bag of cement laid over roof when it is green including cost of all materials, seigniorage charges, excluding conveyance charges of materials and including all operational, incidental and labour charges for mixing mortar, laying, rendering smooth and thread lining, curing, rounding off junctions of wall and slab etc,, complete for finished item of work and as per the technical specification
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Supply delivary and fixing RCC Jalles 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing etc complete as per the technical specification
Supply and fixing Aluminium Anodised Doors - Single Shutter as per approved drawing with aluminium anodised sections of Jindal sections and outer frame top horizontals & both verticals of 2408 of size 101.6 x 44.75 x 3.18 mm Shutter frame top, bottom and verticals of 4504 of size 44.45 mm x 47.62 mm x 3.18 and Middle lock rail of 4621 of size 49.91 x 44.45 x 3 mm with tinted-bronze/green glass 5 mm thick(middle to top),MDF Board-exterior both sides laminaed 12mm thick(middle to bottom) fixed including supply and fixing aluminium handles of 150 mm for each shutter and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specification 1.2x1.2
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specification
Providing and fixing factory made polyvinyl chloride (PVC) Door Frame of the size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined with 2nos. of 150mm long brackets of 15x15mm M.S. square tube. The two vertical door profiles are to be reinforced with 19x19mm M.S. Square tube of 19 gauge. The door frame shall be fixed to the wall using 65/100mm long M.S. Screws through the frame by using PVC fasteners. A minimum of 4nos. of screws to be provided for each vertical member & minimum 2nos. for horizontal member etc. complete as per manufacturers specification and direction of Engineer-in-Charge for finished item of work as per the technical specification.
Providing and fixing 30mm thick Solid panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19mm x 19mm for stiles, & 15mm x 15mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame shall be covered with 5mm thick heat moulded PVC ‘C’ channel of size 30 x 50mm forming stiles, and 5mm thick, 75mm wide PVC sheets for top rail, lock rail & bottom rail on either side, and 10mm (5mm x 2) thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail. Panelling of 5mm thick PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 30mm wide x 5mm thick PVC sheet beading on either side, and joined together with solvent cement adhesive etc. An additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of the ‘C’ Channel using PVC solvent adhesive. Complete as per direction of Engineer-in-charge, manufacturer’s specification & drawing for finished item of work as per the technical specification.
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe415 / Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Supply,delivery and fixing of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat as per approved design by the department including cost and coveyance and all labour charges for fixing for finihsed item of work and as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification Rain water pipes
Gronolithie Concrete Flooring 20 mm thick with (1:1:2), using 6mm to 12 mm size hard granite machine crushed metal laid over CC bed already laid or RCC roof slab, in alternate panels of size not exceeding 1.50 m x 1.50 m and finishing the top surface etc
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Providing & Placing on Terrace (at all floor levels) polyethylene water storage tank with Double layer approved brand & manufacture with cover and suitable locking arrangement & making necessary holes for inlet & outlets and over flow pipes but without fittings & base support for tanks
Supplying & Fixing Orissa Pan white glazed W.C 1st quality ISI marked conforming to IS:2556-Part-3-1981 with "P" or "S" trap Hindware/ Parryware/ Neycer - ISI Mark: 630 mm x 450 mm size
Supplying & Fixing low down porcelain flushing tank 10 Lit Capacity Hindustan Sanitary ware/ parry/ Neycer with internal components
Supplying & Fixing Indian make Flat Back Wash Hand Basin (HSW/Parryware/ Neycer) 1st quality conforming to IS:2556-Part-4:1972 with waste fittings like rubber plug, chain, 32 mm nominal size C.P. Fitting with parallel pipe thread conforming to IS:2963-1979 and fitted with 15 mm nominal bore Chromium Plated Pillar Tap of 1st quality Indian make 400 grams Seiko/ Senior/ Nice/ Esso or equivalent complete with standard CI brackets including wooden block: 550 x 400 mm - Double C.P. Pillar cock
Supply of 110 mm dia 3 m single Socket PVC/SWR pipe - 6 Kg/sq.cm - Prince/Sudhakar/Kisan/Supreme or any ISI Brand.
Supply of 110 mm dia - Plain Bend 87.5 Degree - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand)
Supply of 110 mm dia - Coupler - UPVC/SWR Pipe fittings (Prince/Sudhakar/Kisan/Supreme or any ISI Brand
Labour charges for laying, fixing and commissioning the PVC pipes including couplers/ bends/ tees etc any diameter including fixing necessary fittings like bends, plugs, couplers, junctions, tees, etc with solvent jointing as per standard practice
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in CM 1:6 prop. Masonry. Inspection chamber up to 914.4 mm (3'0") and fitted with light weight 457.2 mm x 457.2 mm (1'6"x1'6") C.I frame and cover of 20 Kg
Supply and Fixing of GI pipe Medium Grade properties & weight as per IS 1239 ISI mark with GI fittings including the cost of pipe & its fittings & labour charges complete as per Technical Specification
25 mm dia nominal bore -from tank to jn for of individual lines
20 mm dia nominal bore -from jn for of individual lines to toilets & Kitchen
15 mm dia nominal bore -for internal
Supply and fixing of GI & GM fittings as per Technical Specification
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 25 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 20 mm NB Size
GM Ball valve with SS Ball and SS Spindle as per IS - Class - I, Indian make heavy type - 15 mm NB Size
Supply and fixing of 12.7 mm N.P bib tap Indian make heavy dutys Seiko/ Senior/ Nice or equivalent
Supply and fixing of GI union Ist Quality as per Technical Specification
For septic Tank
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--mechincal means upto 3m depth for foundations
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:5) prop 12 mm thick including cost of material, labour ,curing etc. complete as per the technical specificationout side & inside
Laying VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specificationcover slabs 0.15 thk
Providing High yeild Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) (FE 415/Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting,bending to required sizes and shapes,placing in position with cover blocks of approved materials and size and tying and lap- splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs & drawings incluidng cost and conveyance of steel bars, including all wastages such as overlaps, chairs, couplings,spacer bars including cost and conveyance of binding wire , cover blocks and all incidental , operational, labour charges such as cutting bending , placing in position , tying and as per Technical Specification.
Construction of chlorine contact room near zph school
Earthwork excavation by Mechanical in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying insitu VCC M-10 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying VRCC M-30 grade design mix using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
For1st footing
Pedastals
Columns (BGL)
Plinth beam
Lintle beams Windows
Roof Beams
Roof slab
Sunshades
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification-GF
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification-FF
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of Walls and as per Technical Specification
Plastering with CM (1:5), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of Parapet wall and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of Cealing work and as per Technical Specification
Plastering with CM (1:3), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of Cealing work and as per Technical Specification
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and fixing Aluminium Anodised Two/ Three Track Sliding Windows as per approved drawing with aluminium anodised sections of Series C Jindal sections and outer frame top horizontals & both verticals of 8774 of size 62 x 29.5 mm and bottom horizontal - two track frame of 8773 of size 62 x 29.5 mm, Shutter frame top, bottom and verticals of 8304 of size 50 mm x 20 mm and Weather interlocking frame of 8306 of size 50 x 20 with plain clear float glass 5 mm thick fixed including supply and fixing aluminium handles of 100 mm for each shutter, nylon rollers assembly and all labour charges for fixing the fixtures with required no.of screws, bolts and nuts and including labour charges for fixing the frame in position, fixing shutter to frame etc. completed for finished item of work and as per Technical Specifiacation.Windows 1.50x1.20m
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Supply,delivery and fixing of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat as per approved design by the department including cost and coveyance and all labour charges for fixing for finihsed item of work and as per Technical Specification
Painting two coats with synthetic enamel paint of approved quality colour and grade-I over a primary coat to new Steel surface including cost of primary coat and cost and conveyance of all materials, labourcharges etc.as per SS and directed by the departmental authorities for finished item of work and as per Technical Specification
Supply and fixing of precast RCC Jollys 50 mm thick includnig cost and conveyance of all material and all labour charges for fixing and as per Technical Specification
Supply, delivery and fixing of reputed ISI make 110 mm dia 4 KSC PVC rain water drain pipes including cost and coveyance and labour charges for fixing and as per Technical Specification
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Supply ,Erection and Commissioning of Crane Gantry Girder of Capacity of 3.00 T including cost and conveyance of all material and all labour charges etc complete as per ISI and as directed by the dept .
Providing Protection Wall for Head Water Works near Gandikota Reservoir
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--manual means upto 3m depth for foundations of buildings in restricted places By mechanical means
Providing river sand filling brought from approved quarry including cost and conveyance of all material and all labour charges such as filling in layers watering ramming etc complete as per the technical specification
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification
Laying insitu VRCC M-25 grade design mix using 20 mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
columns
Plinth beam
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Cement plastering using opc in cm(1:5) prop 12 mm thick including cost of material, labour ,curing etc. complete as per the technical specification SS out side & inside
Colour washing two coats using snowcem over the primery coat conveyance of all labour charges etc., complete as per the technical specification (in and out side)
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Supply,delivery of MS grill gates,window ornamental safety grill ,made with MS flats,MS angles,MS squares etc including welding,finishing,applying red oxide paint as primary coat etc complete as per the technical specification.
Providind Synthic enamil paint two coats over the primery coat excluding cost of primer including cost and conveyance of all matrial and all labour charges etc complete as per the technical specification
Providing approach road from main road to wtp and internal road
Earthwork excavation by Mecanically in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification for Road
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification for Road
Granular sub-base/base/surface course with local materials (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smooth wheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408 MORD. using crusher stone dust
Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD.
Supply distrubution and fixing, installation of Flowmeters, Motorised Valves, Level Indicators including Supervisory Control and Data Acuasation System (SCADA) for controlling and monitoring of the bulk water supply pipelines for Gandikota Reservoir Intake Well, Gandikota WTP (8 MLD), Gandikota CWS-01 (220 KL, CWS), Gandikota CWS-01 Pump House, Gandikota CWS-02 (660 KL, CWS), Kadapa Road-01 (Zone-1, 150 KL, ELSR), Kadapa Road-02 (Zone-1, 600 KL, ELSR), ZPH School (Zone-2, 1000 KL, ELSR), Vinayaka Nagar (Zone-3, 600 KL, ELSR), Rani Vanam (Zone-4, 400 KL, ELSR).
Instrumantation and Automation of the Pumping System:
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for suction, Delivery and common Header with specifications of Water Application: Range: 0-16 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and conveyance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS with specifications of body construction with standard construction, measuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote communication protocol of 4 to 20 ma, temperature safety is in-built to comprehensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Supply and delivery of 25 MM Dia electrical actuated valves for Vaccume operation for each pump with specification of Thread end, 24 V.. DC and required limit switches and manual override facility complete charges including cost and convayance of all the material, labor etc., complete and excluding cost of Taes and duties
For Clear Water Pumping Station as per the above specification
Supply and delivery of DI D/F hydraulic and self-medium operated double chamber diaphragm control valve for the functions of pump control i.e. to ensure smooth startup and shutdown of pumps. Valve shall be activated by line pressure and 24V DC solenoid for its operation. Non-return function in built to prevent surges due to pump trip events. Valve closure started as soon as solenoids are deenergized and limit switch of valve position indicator triggered. The valve can be manually overridden to check function. The main valve body internals shall consist of three basic parts i.e. body, diaphragm assembly and top cover with a spring inside main body. The nylon reinforced natural rubber diaphragm of the valve shall close on a seating arrangement. The control tubing shall include inline filter unit. The coating shall be of epoxy BLUE. Charges including cost and conveyance of all material and labor excluding cost of taxes and duties per SS and as directed by the department officer
DN 150 - PN 16 pump control valve for Raw Water Pumping Station as per the above specification
DN 150 - PN 16 pump control valve for Clear Water Pumping Station as per the above specification
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
350MM Dia Above Specification.
Outlet of Raw Water Pumping Station at Gandikota Reaservoir
Outlet of Clear Water Pumping main at Pumping station
Supply and testing of panel mounted 96 mmx 48 mm size on line mounted pH Analyser with Display (4 Digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring Range: 0-14 pH, Process pressure range : 1 bar @ 50 Deg C, Measuring method : Reference, Solution ground : Graphite, electrode body: Glass body (tip), Wetted Parts : Glass tip plastic shaft protection Operating Temp: 0 to 50 Deg C, Protection Class : IP 65 (front) & IP 20 (rear), Communication : RS485, Voltage : 24 V.. DC Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of wall mounted 120(w), 140(H), 77(D) Turbidity analyser with display(4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 1-4000 Ntu, Process pressure range : 2 bar @ 50 deg c, Measuring method : Infrared light 90 deg scatter light method, Max. sampling rate for measured values: 1 Hz, Resolution : 0.01 to 1 depending on measuring range , Measurands : Turbidity & Temperature Operating temp: 0 to 50 deg c, Protection class : IP 67, Communication : RS 485/4-20 mA, Voltage : 24 v.. DC, Sensor case : PVC/POM-C, Optical window: PMMA, Cable : 10 mtrs of Poly made the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Conductivity/ TDS sensor with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: .1 to approx. 1000 μS/cm, Cell constant : 0.1, Process pressure range : 5 bar @ 50 deg c, Measuring method : Conductive 2 electrode, Sampling : 500 msec, Measurands : Conductivity / TDS, Operating temp : -5 to +80 °C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor case: Stainless Steel 1.4571, Body material: PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Clear Water outlet of Water Treatment plant
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Raw Water Inlet of Water Treatment plant
Clear Water outlet of Water Treatment plant
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow & Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Raw Water inlet and clear water outlet at
Supply, errection, Testing & Commissioning of In door type Scada based RTU control panel for Opearating and monitoring of the Raw Water and Clear Water Pumping stations in auto logic and manual operations including synchornize with SCADA and the specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, arrangement of required PLC/ Controller, Ethernet Switch, Required I/O Modules and DI, DO modules, all components powered by 24 V. DC with necesssary control MCB's, Relay cards, fixing of all termination with FTB's, Internal wiring by all power cables with suitable guage of Single core copper PVC sheated cables and all communication cables with SS Brided cables, and the panel having logic for the following and erection with required civil works as per site conditions etc., complete charges including all materials and labour and excluding of taxes and duties and as per SS and as directed by the department officer.
For Raw Water Pumping Station as per the above specification
For Clear Water Pumping Station as per the above specification
Logic for RTU opeartaions: 1. RTU panel for local operaion of the pumps in manual and Auto Mode. 2. All the equipment like Pumps, PCC, MCC, VFD Control panels, Pump Control Valves, Vaccume Valve, Pressure and flow sensors connected to RTU through the cabling with necessary power and communication cables. 3. The pumps can be opearte in Auto mode by the pumping sequence including monitor and opearte the Vacumization, SumpLevels, Suction, Delivery pressures, Pump Monitoting and PCV operating according to site conditions. 4. In Auto management, the pumps can be operate based on the field demand through control the VFD panels according to pump curves. 5. Monitoring the suction and delivery pressures of the pumps and operate under limits assigned. 6. Check all the reservoir demands and switch on and switch off the pumps according to demand under limits of pump curves. 7. In manual opeartion, all the equiment can be run through PLC panel by individual operations. 8.The RTU connected with SCADA for remote monitoring and operation. 9. The RTU have a adequated facility to modify any sequence at any time demanded by the department incharge.
Reservoir Inlet Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
100MM Dia Above Specification.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
150 MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
200 MM Dia Above Specification.
Inlet of 1000 KL Proposed ELSR at MRO Office, Zone-01
Supply and delivery of separate version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
150 MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
200 MM Dia Above Specification.
Inlet of 1000 KL Proposed ELSR at MRO Office, Zone-01
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
100MM Dia Above Specification.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
150 MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
200 MM Dia Above Specification.
Inlet of 1000 KL Proposed ELSR at MRO Office, Zone-01
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
100MM Dia Above Specification.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
150 MM Dia Above Specification.
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
200 MM Dia Above Specification.
Inlet of 1000 KL Proposed ELSR at MRO Office, Zone-01
Supply, errection, testing and commissioning of Ultra sonic/ Altitude Level sensors make of SIEMENS/ ABB/ BAUMER/ DANFOSS / KELLER with specifications of body construction with standard construction, mesuring upto 6.00 Mtr depth, protection clause of IP 65, accuracy is +/- 5%, input power supply is 24 V.. DC, remote comunication protocol of 4 to 20 ma, temperature safety is in-built to comperhensive over temperature range with in the -40 Deg to +80 Deg, installed in both conditions i.e., indoor and outdoor, charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Supply and testing of panel mounted 96 mm x 48 mm size on line mounted Chlorine Analyzer with display (4 digit) make of FM/ JUMO / ABB/ SIEMENS/ HACH with the technical specifications of Measuring range: 0-10 PPM, Cell constant : 0.1, Process pressure range : 1 bar @ 50 deg c, Measuring method : 2 and 3 Electrode principle, Response time : Approx. 2 min, pH Dependency (loss of slope) : In the range from pH 5 to 7: no loss of slope, at pH 8 about 10%, at pH 9 about 20%, (starting from pH 7), Operating temp : 0 to 50°C, Protection class : IP 67, Communication : RS 485, Voltage : 24 v.. DC, Sensor Case: PVC, Body material : PEI, Cable : 10 Mtrs of Polyimide and the charges are including test and calibration certificate, cost and conveyance of all material, labor and excluding cost of taxes.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Supply laying and fixing of tubing for Inlet and out let of raw water and clear water to the analyzers with necessary pipes with compressed fittings charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow,Pressure and Quality Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Erection, testing and commissioning of Reservoir Management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of 400 KL Proposed ELSR at Rani vanam
Inlet of 150 KL Existing ELSR at Kadapa road
Inlet of 600 KL Proposed ELSR at Vinayaka nagar
Inlet of 600 KL Proposed ELSR at Kadapa road
Inlet of 1000 KL Proposed ELSR at ZPH School
24 x 7 Water Supply :: DMA Management ::
supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM, Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per IS - 1538 excluding all taxes, duties and including transportation.
200 MM Dia Above Specification.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply and delivery of Separate Version Electro Magnetic Flow Meter MAG 5100 model or equilant with the specification of flow body as per company standards, electrodes of SS316, accuracy of +/- 2%, cable length of 20 Mtrs, end connection of ANSI flanges as IS/DIN standards, flow bore protection is IP68, earth rings of SS ( If required as per site condition) flow transmitter body as per company standard and two line display, transmitter having 4-20mA, RS485 and modbus communication for data transfer through any network, power supply of 24 volts DC , and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer.
200 MM Dia Above Specification.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply and delivery of Electrically switched, DI D/F hydraulic and self-medium operated diaphragm Control valve for the functions of Pressure & Flow control at Tank inlet with the function to maintain a constant downstream flow and pressure by controlling the differential pressure between the inlet and outlet of an orifice plate, regardless of pressure variations. The valve shall be of globe pattern inline or angular pattern with a main valve body of full or reduced bore designed for full differential pressure. The seat shall be of stainless steel which is replaceable.The valve can use manually and electrically with 24 V.. AC/DC for operation. The control tubing with self cleaning filter unit to functions as per customer requirement. The internal & external coating with liquid/Powder form epoxy coating, all fastners with SS including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
200 MM Dia Above Specification.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply ad delivery of M.S. Dismantling Joints /SS, D/F expansion bellows with specifications of bellow with SS ASTM A 240 TP 304 grade, tie rods with EN8/IS-2062 Grade, End connection flanges with IS 2062 Gr.B Sorf plate, Drilling and dimensions as per approved drawing as required by customer at the time of order confirmation charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
200 MM Dia Above Specification.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Providing, Installation, Testing and Commissioning of PRESSURE TRANSMITTER for Water Application: Range: 0-10 Bar / Power Supply: 24 V DC / Output: 4-20 mA / Diaphragm: SS316L / Process Connection: 1/2 "NPT (M) / Accuracy: 0.15% Protection: IP67 . The cost also includes the calibration of all the sensors manifold etc., complete including cost and convayance of all material and labor excluding cost of taxes and duties and as per SS and as directed by the department officer
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply, errection, Testing & Commissioning of Out door type PLC/Controller based Automation and communication Panel fabricating with 16 SWG CR sheet, internal and external surface coating with Epoxy powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the Control & Monitoring the Level, Flow, Pressure and Qaulity Parameters and Comunicating with Central SCADA for Auto logic, Local and Remote operation of the valves with specifications of fabricating with 16 SWG CR sheet, internal and external surface coating with powder coating, making internal wiring with suitable wires including nomenclature. The panel is suitable for the above operations with PLC/Controller, communication modules, HMI, Power back up and necessary modules and as per site conditions etc., complete charges including all material and labor and excluding of taxes and duties and as per SS and as directed by the department officer.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply laying and jointing of 4 Sq.MM - 2 core PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping with in the Head works compound/ pumping stations/Individual OHSR's and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Supply laying and jointing of 0.75 Sq.MM - 4 core SS Brided and PVC sheeted cable make of LAPP/Orbit/Polycab/Finolex for solar / Raw power for the instrumantation and automation at Raw water and clear water pumping/ with in the Head works compound/ pumping stations/ Individual OHSR,s and laying with necessary cable trays/Condutes/ Civil works from each and every panel through side walls/cealing / floorings etc., where ever is necessary with all related civil works etc., charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Erection, testing and commissioning of DMA management unit including dejointing of existing pipeline / flange joints, taking out already laid DI/MS or any kind of pipe barrel piece, lifting the said pipe, cleaning & returning to the departmental store as per direction of the Engineer-in-charge and lowering, aligning & placing the flow Meter unit, jointing the same with fabricating of fittings, reducers, flanges with necessary MS material as per flow meter manufacturer standards and as per the site conditions with necessary lifting equiment, fabrication works, fixing with new Nuts , bolts and Rubber insertion with arrangment of necessary earth work excavations, MS clamp brackets, lifting equipment, retrofit works to complete the job as per site condition (Excluding cost of Meter, Valve& Expansion bellow etc.,) charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2 & 3 under 1000 KL ELSR at ZP High School
Pressure points at Highest Point, Lowest Point & Furthest Point
Inlet of DMA-1, 2 & 3under 1000 KL ELSR at ZP High School
Under 600 KL ELSR at Prakash nagar
Under 750 KL ELSR at Hindu Burial ground
Integration of PLC panels with Developing necessary softwares and programming as per field condition and user interface, communicated from each panel and intigrated with central SCADA station charges excluding cost of taxes and duties including cost and conveyance of all material including transport and labor etc., complete and as directed by the dept., officer.
Inlet of DMA-1, 2 & 3under 1000 KL ELSR at ZP High School
AMR Water Meter Management.
Providing, Installing and satisfactory field testing of domestic Water Meter with AMR Compatible Mechanical Water Meters with the specifications of minimum Dynamic ratio (Q3/Q1) of 160:1, fully body made up of composite material/ Brass/ Bronze, the metal Material that come in contact with the water supply shall withstand 2 ppm (Parts per million) of chlorine residual in the water supply and shall be resistant to corrosion, mechanical inferential type, multi jet, magnetically coupled, having dry dial, protection class of IP-68, Class ’B’ confirming to IS-779: 1994 with up to date amendments or ISO 4064:2014 standard with ISI/EEC/OIML/MID/CE certification mark shall be with meter and offer 5 years warranty and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-A.
DN 15 - PN 16 AMR Compatible Mechanical Water Meter as per above specification for all reservoirs comman area
Supply, Delivery, Installing and satisfactory field testing of AMR Unit for domestic Water Meters from 15 mm to 40 mm with the specifications of fully body made up of composite material, magnetically coupled in between meter and AMR module, protection class of IP-68, In built battery with 3.60 V... Lithium Battery for life of 10 Years based on one communication /Day, Communication interface in between meter and AMR unit with Pulse/ Photo Electric, AMR unit can fetch the data from meter on hourly basis and store the data for 48 Hours on FIFO basis and send the data through NB IoT in every 24 Hours without fail through the provider registered in DOT, India, if the communication fails due to bad communication the AMR module can try for a maximum six times in different time intervals to ensure the data to reach to server. The AMR unit have option of Bluetooth for remote configurations at field. In the special event and field testing the data sending interval of AMR unit can be configurable and minimum time interval span is one Hour (The battery life can be calculated based on the time intervals of data communication) The data storage should be kept in Indian data centres for the data security, AMR unit can be registered the abnormalities like Reverse flow, Leak detection, Tampering and send to the server via reading data packet, Every communication from the AMR module to server should be in JSON format with real time stamping, The AMR can suitable for all the Mechanical Water meters supplied by the agency in this contract. The AMR Module offered with 5 years warranties and submittion of manufacturer test and calbrationreports charges and all charges including cost and conveyance of all material , freight, transport and labour etc and excluding of GST etc., complete, and as directed by the dept., officer. Note: Detailesd technical specifications enclosed as Anexure-B
Inlet of DMA-1, 2 & 3under 1000 KL ELSR at ZP High School
Supplying and Fixing water meter BOX- with Weather resistant FRP box, press fitted Lid fixing & locking and locked with built-in or external lock. Charges including breather, NBR bushes for pipe entry, SS Grouting screws etc., complete and as directed by the departmment officer.
Local SCADA Control Sation:
Establishment of HARDWARE for Individual Local Control Station at Individual ULB ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Desktop PC Station with specification of I7 Processor, 8 GB Ram, ,512 GB SSD, Licensed OS, 21" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL - 1 Job
55" LED Display make of Sony/Samsung/ LG or equilant with ethernet/HDMI/VGA supported for front end view by connecting with PC in dual mode operation and View the SCADA screens with required cables and connectors etc., complete.-1 Job
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank, make of Vertex/EATON/ BPE/ NUMERIC /RIELLO / ENERTECH complete -1 Nos
3 in one on line B/W A4 Lazer Jet printer -1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Local SCADA station atYemmiganurMunicipality with the above specifications.
Development of Softwares for Individual Local Control Station at Individual ULB ::
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Local control station where the SCADA room will be developed by the local ULB for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Local SCADA station at Yemmiganur Municipality with the above specifications.
Central Station at Kadapa Circle Level Yerraguntla :
Establishment of HARDWARE for Central Control Station at Individual Circle ::
Supply, erection, testing, commissioning of Hard ware for the SCADA system for Central control station where the SCADA room will be developed by the local Circle for operting & View from Service Reservoirs, DMA and AMI meter management for entire circle where the instrumantation and automation developed under this project and synchornization by deploying the following components including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Supply and commissioning of Floor mounted/Rack server Dual Processor, 8 GB Ram x 2 Nos, Hard Disk - x 3 Nos of 1TB with raid control, Licensed OS, Mouse, keyboard and relevant accessories make of IBM/LENOVA/HP/DELL complete -1 Job
86" Interactive Display make of SENSES/ LG/ SAMSUNG/ BENQ or euilant with ethernet/HDMI/VGA supported for front end view of SCADA for monitoring, Graphical or Trends, MIS reports for the group of ULB,s or individual ULB under the circle with required cables and connectors etc., complete.-1 Job
16 port Unmanaged Switch with specifications of 220 V.AC/ 24 V.. DC., 16 No of LAN ports, Rack Mounted, Speed 100/1000 Mbps, compatable with make of CISCO/ HP/ FF/ ONV/ phoenix complete -1 No
Desktop PC Station with specification of I 7 or equilant Processor, 8 GB Ram, 512Gb SSD, Licensed OS, 24" Screen with Mouse, keyboard, and relevant accessories make of LENOVO/ HP/ DELL -1 Nos3
Modem with specifications of Fibre Port having ILL, PON & Network Features, Speed 100/1000, LAN Ports, Fibre port x 1 N0 make of CISCO/ HP/ FF/ONV/PHOENIX/Dlink/ Suggested by the telecom provider-1 No
3 KVA Stabilizer with specifications of 220 V.AC Input/ 220 V.AC output, necessary terminal wires etc., complete complete -1 Nos
3 KVA online ups with specifications of 220 V.AC Input/ 220 V.AC output, Static By pass with isoltion transformer, Required Battery bank for 1 Hr. back up, make of Vertiv/ EATON/ BPE/ NUMERIC /RIELLO / ENERTECH or equilant make complete -1 Nos
Fire wall application make of SOPHOS/ FORTINET or equilant make.-1 Nos
Network for all local control stations and central station with registration with any communication provider and payment of minimum one year subscription and establishment of communication -1 Job
Establishment of Central Unit with above specifications for Kadapa PH Circle.
Development of Softwares for Central Control Station at Circle Level :
Design, Development, Deploy, testing & commissioning of Firmware for the WEB based SCADA system for Central control station where the SCADA room will be developed by the Circle for operting & View from Service Reservoirs, DMA and AMI meter management and where the instrumantation and automation developed under this project by synchornization with the field instruments, configuration with the following features including cost and convayance of all material, user licences, communication networks, etc., complete and as directed by the department officer.
Development and providing the WEB based SCADA for Operation and Monitoring by the individual ULB where implemented the Reservoir management to AMI management. (Expandable upto Source to end user)-1.00 Job
Development of front end view monitoring and operating application in Digital Twin Mode with 3D & 2D model including designing, animation, drawings and integration of SCADA with field devices through MQTT/ MODBUS/ TCPIP protocol etc., complete. -1 Job
Develop, Supply, install and commissioning of customized WEB applications for Data analytics, Visulation, Trends, Data auditing, generating the reports as required by the customer at the time of commissioning -1 Nos
Develop, Supply, install and commissioning of Anroid & IO's application for data monitoring by through Mobi-APP as required by the customer at the time of commissioning complete -1 Nos
Establishment of Central Unit with above specifications for Ananthapuram PH Circle.
Construction of Clear Water SCADA Room 8.00 x 12.00 Size.
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Laying PCC M 7.5 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Construction of RR Masonary in C.M (1: 6) prop. Using hard granite stone including cost and conveyance of all materials like cement, sand, water, Granite stone etc. including cost of seigniorage charges on all materials, all taxes including labour for cutting stones to required size and shape, mixing of cement mortar construction, Scaffolding charges etc. complete for finished item of work as per the technical specification
Laying VRCC M-30 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification for Bed.
Laying VRCC M-30 grade cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification For Side Walls of Septic Tank.
Laying VRCC M-25 grade design mix using 20 m/c mm down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
Footings
Pedastals around Columns
Columns Up to plinth
Plinth Beams 300 x 400
Columns
Beams 230 x 500
Lintels
Sunshades
Staircase
RCC Slab 150mm thick
Providing High Yield Strength Deformed (HYSD)/ Thermo Mechanically Treated (TMT) steel bars ( Fe 500 grade as per IS 1786-1979) of different diameters for RCC works , including labour charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying and lap-splicing with binding wire of 18 SWG, forming grills for reinforcement work as per approved designs and drawings, including cost and conveyance of steel bars, including all wastages such as overlaps, couplings, chairs, spacer bars including cost and conveyance of binding wire, cover blocks and all incidental, operational, labour charges such as cutting, bending, placing in position, tying and as per Technical specification
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification GF
Brick Masonry in CM (1:6) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification-FF
11.5 cm wide Brick masonry for super-structure on ground floor in cm (1:3) using second class traditional size bricks including cost of all materials, seigniorage charges, labour and all operations for constructing half brick masonry, mixing cement mortar, curing etc., complete for finished item of work, including cost and conveyance charges of materials.
Plastering with CM (1:4), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification GF
Plastering with CM (1:4), 20 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification FF
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification inside and ceiling
Flooring with 50 mm thick Rough Cuddapah/Shabad stones, set over base coat of cement mortar (1 : 8) 12 mm thick over CC bed already laid or RCC roof slab, including pointing with cement mortar 1:3 duly filling joints nearly, including cost of all materials like flooring stone, cement, sand, and water etc., complete, including seigniorage charges, labour charges for dressing of flooring stones etc., complete for finished item of work as per the technical specification, but excluding the cost of conveyance of all materials.
Flooring with ceramic tiles, set over base coat of cement mortar (1:8), 12 mm thick over CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3.kgs per sqm & jointed neatly with white cement paste to full depth mixed with pigment of matching shade, including cost of all materials like cement, sand water and tiles etc., complete, including seigniorage charges, etc., complete for finished item of work as per the technical specification, including the cost of conveyance of all materials.
Dadooing to walls with first quality glazed coloured tiles approved colour of any size set over base coat of C.M(1:3)prop. 12mm thick and neat grey cement slurry of honey like consistency spread at the rate of 3.3Kg of cement per sqm and jointed with neat white cement paste at 0.20 kg per sqm mixed with pigment of matching shade to match the shade of tiles including cost and conveyance of all materials labour charges, water to work site,seignourage and all operational .incidental , mixing mortar , fixing in position ,lift charges, curing etc., complete as per SS or as directed by the departmental authorities for finished item of work as per the technical specification.
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint over Priming Coat, 2 Coats (All Colours) including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.
Providing & Fixing of Scientific Doors with metal door frames and door shutters made of galvanize steel (base steel as per IS 513 of 0.58 mm thick D quality, galvanized as per IS 277 with Zinc of 120 GSM) pure polyester powder upto 50-60 microns thick, outer frame section of 100 x 58 mm x 1.2 mm thick, shutter section of 0.80 mm thick galvanized steel sheet pressed (roll formed) for 46mm thick fully flush, double skin door shell seam joints at stile edges, in-fill of honeycomb kraft paper used to give the equired rigidity and effective acoustic insulation with 6” Tower bolt – 1 No., 6” D handles – 2 Nos., 10” Aldrop – 1 No., Butt Hinges – 3 Nos, Mortise Lock of approved quality – 1 No, frames fixed to the concrete/masonry wall by means of self expanding screws complete for finished item of work and as per Technical Specification. for Single leaf Door
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work.Windows: Double shutter 3'-0" x 4'-0" (914.4mm x 1219.2 mm) outer frame section size of 46 x 52 mm shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm.
Providing & fixing 30 mm thick solid panel PVC door shutter consisting of frame made out of 19 guage M.S tube of 19 x 19 mm for stiles, top & bottom rail, with a coat of primer of approved make. M.S. Frame covered with 5 mm thick heat moulded PVC “C” channel of size of 30 x 50 mm forming stiles, 5 mm thick 75 mm wide PVC sheet for top, lock & bottom rail on either side 20 mm wide cross PVC sheet as gap insert for top & bottom rail, panelling of 10mm(+/-)( 5mm+5mm)” thick PVC sheet fitted in the M.S. frame welded /sealed to the stiles, on either side joined together with solvent cement adhesive etc., additional 5 mm thick PVC strip of 20 mm width stuck on the interior side of the C channel using solvent cement, complete as per direction of Engineer–in–charge, manufacturers specification.
Ventilators: Top Hung 4 '-0" x 3'-0" (1219.2x914.4mm) outer frame section size of 46 x 52m m shutter frame section size of 46 x 46 mm Mullion section size of 46 x 70 mm. and as per Technical Specification.
Providing and fixing Thermocole False ceiling in true horizontal level 600 mm x 600 mm using 15 mm/ 19 mm thick Thermocole sheet anodised Aluminium Tee sections of size 24.50 mm x 24.0 mm x 2.4 mm in grid with cross tee of size 24 x 24.5 mm at every 600 mm c/c and anodised aluminium wall angle of size 24 x 24 mm fixed to periphery of the wall and the above grid is suspended at every 1200 mm c/c in both directions using 2.0 mm thick GI Wire for finished of size 600 x 600 mm including Cost &conveyance of all materials and labour charges such as cutting , fixing of standing of frame work exposing roof making complete for finished item of work and as per Technical Specification.
Supply and fixing of 25 mm dia 2.00 mm thick PVC pipe concealed in roof slab with all required accessories including masonary work all labour chages
Supply and fixing of 20 mm dia 1.50 mm thick PVC pipe concealed in walls with all required accessories including masonary work for light , fan and plug point with metal deep box including all labour charges
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A siwtch, ceiling rose and 3 mm thick hyla sheet covering to switch control box including all labour charges etc,., complet for light, bell , fan and exhaust fan points in non - residential building
Wiring with 2 runs 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe with 6A modular siwtch control and 3/2 pin sockets fixing on board including all labour charges
supply and run of 2 of 36/0.3 mm. (1.5. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for mains including all labour charges
supply and run of 1 of 14/0.3 mm. (1.0. sq.mm) Fire retardant PVC insulated Flexible copper cable in existing pipe for earth continuity including all labour charges etc.
supply and run of 2 of 6 sq.mm (7/18) WPSC alluminium cable along with No.10 SWG G.I barer wire through PVC cleats with all accessories including all labour charges etc.,
Providing independent earthing by excavating a trench to a depth of 2.10m in all soils, as per size specied in data ,using 40 mm dia B class GI pipe 2.50m long with necessary accessories with hume pipe ring duly providing staggered holes including filling with equal proportion of salt and charcoal in layers and all labour charges etc complete
Supply and fixing SPN Distribution board with IP-20 protection suitable for single phase Earth Leakage Circute Braker (ELCB) / Residual Current Circute Braker (RCCB) / Double Pole (DP) Isolator as incomer and 10kA SP MCBs as out going including internal connections and labour charges for surface / flush mounting etc., complete.
Supply and fixing of 48" (1200mm) Sweep Ceiling Fan without Regulator.of makes Crompton High Speed / Bajaj Ultima / Havells Velocity / Usha Astra / Orient Summer Pride
Supply of stepped type Electronic Regulator of makes GM G Home / Gold Medal Olive / Million Zoom / Anchor Penta Cherry / Great white Omega
Supply and transportation of 20W, 2000 lumens, T8,1200mm length LED retro tube light,wide operating voltage with double side connection, PF≥0.9,Surge protection: > 2KV, THD<15%, with inbuilt driver and frosted cover CCT: 3000K - 6500K as desired by the department and as per IS specifications, minimum CRI≥80,.etc complete with 5 years warranty.LUMINAIRE MAKE: Phillips / OSRAM / GE / Crompton /VIN / Bajaj / Havells / Halonix / HPL. LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /OSRAM / SAMSUNG / LG LEDs.
Labour charges for Fixing of Ceiling fan and regulator including transportation and giving connections with twin core wire etc., complete
Labour charges Fixing of 40W tube light luminaire on wall / Ceiling with / TW round blocks with all accessories including giving connections and all labour charges etc., complete.
Supply and fixing of 16A 3/2 pin flush type wall plug modular socket with shutter and 16A modular switche controll on a common switch board with earth continuity including wire leads, earth connections along with all labour charges etc., complete. Makes of Switches : GM G Home /Anchor Penta Cherry / Gold Madel Olive / Million Zoom / Great White
Supply of 1.5 TR, 3 Star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R-410A. Makes: As per list of recommended brands as category INVERTER Model Cool type split AC unit with high wall mounted Single Split indoor unit and outdoor condensing unit Hermetically sealed compressor suitable for operation on 230V, 50Hz, 1Phase AC supply capable of performing Heat cool dehumidifying air circulating and filtering with cooling and condensing units with 3 mts of copper piping, insulation kit and 4 mts of 4 core copper flexible chord with cordless remote control etc., dual barrier coating in order to protect coil form oxidation with copper condenser 1.5 TR, 5 Star capable of delivering 18000 BTU/hr and above with operating on refrigerant R-32/ R- 410A.Makes: As per list of recommended brands ascategory I. ELEC-5.5.1 Aa
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 14.347 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-I.
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manual means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water with oil driven pumpsets, including hire charges, fuel charges for driver & helper all labor charges and incidental charges and as per Technical Specification
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification.
Supply and Delivery of HDPE Pipes of pressure 6Kgs/ Sqcm and 100 grade confirming to IS: 4984 - 1995 including transporation to any where in AP.excise duty, sales tax and excluding specials etc complete as per standard specifications
110mm dia.
160mm dia.
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST and as per Technical Specification.
250mm dia.
315mm dia
400mm dia
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
160mm dia.
200mm dia
250mm dia.
c) End Caps
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
e) TEES
110mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
F)Bends
110mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST and as per Technical Specification.
Reducers
200x250 mm dia
250x315 mm dia
200mm dia OPVC pipe
250mm dia OPVC pipe
315mm dia OPVC pipe
Bends
200mm dia OPVC pipe
250mm dia OPVC pipe
315 mm di OPVC
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
200 mm dia
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification.
250mm dia.
315mm dia
400mm dia
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
DIDF pipes for scours
100x1.00m long DF pipes for sluice valves
150 mm dia x2.00m on 200 and 250 mm dia pipes for scours
150x1.00m long DF pipes for sluice valves
200 mm dia x2.00m on 315 and 355 mm dia pipes for scours
200x1.00m long DF pipes for sluice valves
250x1.00m long DF pipes for sluice valves
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification (PN-1.6))
100 mm distrubution
100mm dia sluice valve for scour
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
300mm dia for distrubution
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pies with flanged (welded) ends for water, gas, sewage conforming to I.S.: 8329/2000 in standard working Lengths of 1,2,3, 4, 5 mts. for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating. The rates are including transportation to site of work labour charges for loading & Unloading and stacking as per standards and all incidental charges and also taxes & duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
Jointing the DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500m and testing to required pressure complete and as per Technical Specification.
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
Labour charges for lowering and keeping in position of D.I sluice valves, reflux valves and scour valves and as per Technical Specification.
100 mm distrubution
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
300mm dia for distrubution
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm [1.80*1.80*1.50 Mts]
150mm [1.80*1.80*1.50 Mts]
200mm [ 2.00*2.00*1.70 Mts]
250mm [ 2.00*2.00*1.70 Mts]
300mm [2.10*2.10*1.80 Mts]
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete for road restoration
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD. (CC pavement) for Road restoration.
Barricading, hoarding, lighting and diversion of traffic, providing caution boards and watching for water supply and sewerage works including all labour charges, incidental and operational charges etc., complete.
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 4.629 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-II.
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manual means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water with oil driven pumpsets, including hire charges, fuel charges for driver & helper all labor charges and incidental charges and as per Technical Specification
Barricading, hoarding, lighting and diversion of traffic, providing caution boards and watching for water supply and sewerage works including all labour charges, incidental and operational charges etc., complete.
Collection, Supply and filling of sand to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. as per technical specification
Supply and Delivery of HDPE Pipes of pressure 6Kgs/ Sqcm and 100 grade confirming to IS: 4984 - 1995 including transporation to any where in AP.excise duty, sales tax and excluding specials etc complete as per standard specifications
110mm dia HDPE PE-100 gr Pipe
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
160mm dia.
200mm dia.
250mm dia.
c) End Caps
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
e) TEES
110mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
F)Bends
110mm dia HDPE PE-100 gr Pipe
160mm dia HDPE PE-100 gr pipe
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia
200 mm dia
250 mm dia
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST and as per Technical Specification.
250 mm dia
315mm dia OPVC
400mm dia OPVC
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification.
250 mm dia
315mm dia OPVC
400mm dia OPVC
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification (PN-1.6))
100mm dia sluice valve for scour
150mm dia sluice valve for Distribution
200mm dia sluice valve for Distribution
250mm dia sluice valve for Distribution
300mm dia sluice valve for Distribution
Labour charges for lowering and keeping in position of D.I sluice valves, reflux valves and scour valves and as per Technical Specification.
100mm dia sluice valve for scour
150mm dia sluice valve for Distribution
200mm dia sluice valve for Distribution
250mm dia sluice valve for Distribution
300mm dia sluice valve for Distribution
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100mm dia [1.80*1.80*1.50 Mts]
150mm dia [1.80*1.80*1.50 Mts]
200mm dia [2.00*2.00*1.70 Mts]
250mm dia [2.00*2.00*1.70 Mts]
300mm dia [2.10*2.10*1.80 Mts]
Jointing DI pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, rubber insertion, white lead including filling with water, with lead up to 500 meters and testing to required pressure complete and as per Technical Specification
100mm dia sluice valve for scour
150mm dia sluice valve for Distribution
200mm dia sluice valve for Distribution
250mm dia sluice valve for Distribution
300mm dia sluice valve for Distribution
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Construction of un-reinforced, plain cement concrete pavement, thickness as per M30 (Grade) design, over a prepared sub base, with 43 grade cement, coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 mictron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying primer, sealant, near approaches to culvert and construction joints, admixtures as approved, curing of concrete slabs for 21 - days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification. for Road Restoration
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 8.22 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-III.
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manual means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Barricading, hoarding, lighting and diversion of traffic, providing caution boards and watching for water supply and sewerage works including all labour charges, incidental and operational charges etc., complete.
Supply and filling with Sand complying with standard specifications including cost and conveyance of sand to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work and as per Technical Specification
Supply and Delivery of HDPE Pipes of pressure 6Kgs/ Sqcm and 100 grade confirming to IS: 4984 - 1995 including transporation to any where in AP.excise duty, sales tax and excluding specials etc complete as per standard specifications
110mm dia.
160mm dia.
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST and as per Technical Specification.
250mm dia.
315 mm dia
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
c) End Caps
110mm dia.
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
e) TEES
110mm dia.
160mm dia.
F)Bends
110mm dia.
160mm dia.
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST as per Technical Specification
A) Reducers
200x250 mm dia
250x315 mm dia
B) TEES
200mm dia.
250mm dia.
C)Bends
90deg Elbow DN 200mm
90deg Elbow DN 250mm
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure and as per the Technical Specification.
110mm dia.
160mm dia.
200 mm dia
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
250mm dia.
315 mm dia
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification (PN-1.6))
100 mm for scour
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
300 mm dia for distribution
Supply and delivery of Centrifugally cast (spun) Ductile Iron pressure pipes with flanged (welded) ends for water conforming to I.S.: 8329/2000 for classification k9 with Cement mortar lining inside the pipes with outside Zinc coating including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
250 mm DF pipes 1.00 m long
200 mm DF pipes 1.00 m long
150 mm DF pipes 1.00 m long
Jointing the DI Pipes, fittings and valves with flanged ends including cost of jointing materials such as bolts, nuts, rubber insertion, white lead and including filling with water with a water lead upto 500m and testing to required pressure complete as per the technical specification
250mm dia valve
200mm dia sluice valve
150mm dia sluice valve
Labour charges for lowering and keeping in position of D.I sluice valves, reflux valves and scour valves and as per Technical Specification
100 mm for scour
150mm dia for distrubution
200mm dia for distrubution
250mm dia for distrubution
300 mm dia for distribution
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
100 mm [1.80*1.80*1.50 Mts]
150mm [1.80*1.80*1.50 Mts]
200mm [ 2.00*2.00*1.70 Mts]
250mm [ 2.00*2.00*1.70 Mts]
300 mm [2.10*2.10*1.80 Mts]
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete for road restoration
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD. (CC pavement) for Road restoration.
Laying of 400mm to 200mm dia O-PVC and 160 mm to 110 mm HDPE pipes for providing 24 X 7 distribution system for a length of 9.561 Km including road restoration, DI sluice valves, DI air valves, valve chambers etc in Zone-IV.
Earthwork excavation by Mechanical means in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as pe Technical Specification
Earthwork excavation by Manually in all types of soils for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Ordinary Rock blasting not required for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Earthwork excavation in Hard Rock (blasting Prohibited) for structures as per drawing and technical specifications including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material and as directed by the departmental Officer including all Incidental and operational Charges etc Complete and as per Technical Specification
Bailing out water from the pipe line trenches with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper etc complete.
Barricading, hoarding, lighting and diversion of traffic, providing caution boards and watching for water supply and sewerage works including all labour charges, incidental and operational charges etc., complete.
Collection, Supply and filling of sand to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. as per technical specification
Supply and Delivery of HDPE Pipes of pressure 6Kgs/ Sqcm and 100 grade confirming to IS: 4984 - 1995 including transporation to any where in AP.excise duty, sales tax and excluding specials etc complete as per standard specifications
110mm dia.
160mm dia.
Supply & Delivery of PVC-O Pipes of Class-500 homogenous Spigot high pressure pipes confirming to IS: 16647-2017 inclusive of EPDM gasket seals on joints and transportation anywhere in Andhra Pradesh, excluding GST and as per Technical Specification.
200mm dia.
250mm dia.
400mm dia.
Supply and Delivery of HDPE fittings conforming to IS 4984 - 1995 including cost and transportation to site of work and stacking as per standards including all taxes and duties but excluding GST and as per the Technical Specification.
a) Pipe ends - long neck
110mm dia.
160mm dia.
c) End Caps
110 mm dia HDPE PE-100 gr pipe
d) Reducers
110X125 mm dia
125x140 mm dia
140x160 mm dia
160x180 mm dia
180x200 mm dia
e) TEES
110 mm dia HDPE PE-100 gr pipe
160mm dia.
F)Bends
110 mm dia HDPE PE-100 gr pipe
160mm dia.
Supply and delivery of at Site of moulded or fabircated OPVC fittings compatible with OPVC pipes conforming to IS 16647 - 2017 to anywhere in Andhra Pradesh, excluding GST and As per Technical Specification
d) Reducers
200x250 mm dia
250x315 mm dia
e) TEES
200 mm dia
250 mm dia
F)Bends
90deg Elbow DN 200mm
90deg Elbow DN 250mm
Lowering, Laying and jointing of HDPE pipes by butt fusion welding as per IS:7634 – part-II/1975 as amended from time to time true to the alignment and gradient and testing the pipeline to the required testing pressure including all labour charges & incidental charges etc., complete and as per the Technical Specification.
110mm dia.
160mm dia.
Lowering, laying, jointing and testing to hydralic test pressure including cost of water with minimum water lead of 500m for OPVC pipes in ready made trenches true to alignment and gradient including all sundries but excluding cost & conveyance of pipes from source of supply and jointing materials as per Technical Specification
200mm dia.
250mm dia.
400mm dia.
Supply and Delivery of Centrifugally Cast (Spun) Ductile Iron Fittings conforming to IS: 9523/2000 Zinc Coated Externally with Inside Mortar Lining (With Finishing as per class 13/IS 9523/2000) including Transportation, Taxes and Duties but excluding GST and as per Technical Specification
Supply and delivery of PN 1.6 DI/DF "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) conforming to IS 14846 latest amendment and material of construction (As per latest codes) as per technical specification of the tender document including cost and conveyance and stacking as per standards and directed by Engineer - in - Charge and as per Technical Specification (PN-1.6))
200 mm distrubution
250 mm distrubution
for scour
Labour charges for lowering and keeping in position of D.I sluice valves, reflux valves and scour valves as per Technical Specification
200 mm distrubution
250 mm distrubution
for scour
Construction of RCC M20 Nominal Mix Valve Chambers Grade as per Type design including cost & conveyance of all materials, labour charges, formwork,machine mixing,vibration , curing etc.complete including cost of M20 Manhole cover ,reinforcement & its fabrication charges. including Earth work,0.10m Thk sand filling,0.10m Thk Bed, 0.10m Thk Base slab ,0.2m thk, side wall,0.15m Thk cover slab and manhole cover
200mm [ 2.00*2.00*1.70 Mts]
250mm [ 2.00*2.00*1.70 Mts]
100 mm [1.80*1.80*1.50 Mts]
Cutting BT road surface as well as asphalt (75mm thick) including water bound. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Cutting the CC road surface. The rate including labour charges for cutting, incidental charges etc., complete as directed by the departmental officer in charge of the work.
Collection, Supply and filling of Stone dust / Quarry spall from approved quarry to work site and stacking at work site for pre measurements including cost and convenyance of all material and all labour charges etc. complete for road restoration
Construction of un-reinforced, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS : 383, maximum in a concrete mixer of not less than 0.2 cum capacity and appropeiate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with sholvels, rakes, compacted using needle, scareed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge / culvert and construction joints, admixtures as approved, curing of concrete slabs for 14- days, curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 MORD. (CC pavement) for Road restoration.
Providing 15mm dia (5604 Nos) new House service connections and Fixing of HSC Supplied Quantity 3563 Nos
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling a) 1 No.of PP Clamp saddles-PP clamp Saddles shall be manufactured by injection moulding using virgin polypropylene. Mechanical tapping saddles for water works purposes and designed for use with PVC/PE pipe as per IS 4985/IS 4984 respectively. These saddles should be contoured to fit around the pipe. PP saddles shall be Blue/Black moulded-in with Nickel plated Brass / SS 304 metal female threaded outlets. Seal shall be thermoplastic elastomer rubber suitable for drinking water and nut-bolt-washer with SS. The PP Clamp saddle fittings shall be mouldedwith SS 304/Nickel plated Brass female threaded outlet inserted to connect necessary fittings. Thread dimension shall conform to IS-554/ISO-7. Adequate thickness of PP shall be provided to hold brass insert in place and avoid leakage while pressure applications. Fasteners shall be threaded type, with SS. Fasteners of size 125mm and above The grade of raw material used must be certified by WRAS, UK for type test as per BS 6920 from their certified laboratories like NSF International Ltd. b) 1 No. of Flow Control valve SS 316 NRV c) 2 No. of Compression adaptor with one side compression end to suit 1/2 "to1''(15mmOD to25 mm OD) MDPE pipe and other side with female threaded with SS-304 material inserts of sizes 1/2" BSP threads, Body, Nut and cap of polypropylene, clip ring of POM(Acetylic resin) and "O" ring of NBR material, as per ISO 14236 standards with pressure rating PN16-2 Nos. d) 2 No. of Double compression elbow to suit 1/2 " to 1'' (15mm OD to 25 mm OD) MDPE pipe body, nuts, and caps of polypropelene, clip ring of POM(Acetylic resin) and and "O" ring of NBR material,as per ISO 14236 standards with pressure rating PN16 . e)MDPE PE80 Blue Pipe of specified length as per ISO 4427 Rev 1. For conveyance of potable water .The pressure rating of ½” (20mm OD) will be PN16. Certificate for compliance of testing these fittings and pipe as per BS-6920 by designated laboratories to be produced. f) 1 No12.7mm Heavy duty brass Bib Cock g) drilling of holes in RCC / RR in compound wall h) holder clamps where ever required i)40mm UPVC pipe for drain crossings wherever required. and as per Technical Specification
Providing house service connections at house holds side in earthern roads
Providing house service connections at other side in BT &CC roads
Providing house service connections at HH side in BT &CC roads
Providing and Fixing of House service connections in to household compound from HDPE mains including earthwork excavation and Refilling excluding HSC's fittings like Saddle,Elbows, ferrule ,MDPE Pipe and Adaptors
Providing house service connections at house holds side in earthern roads
Providing house service connections at other side in earthern roads
Providing house service connections at other side in BT &CC roads
Providing house service connections at HH side in BT &CC roads
Provision for Environmental Management Plan during execution period
Establishing Baseline Data: Air Quality Monitoring once in a month during the Pre-Construction period and once in a month for three months during construction period at Intake well, Sump & PH, Filtration Plant/WTP, ELSRs, Pipelines & Distribution network
Noise level once in a season during the Pre-Construction period and once in a season for three seasons during the construction period at Intake well, Sump & PH, Filtration Plant/WTP, ELSRs, Pipelines & Distribution network
Water Quality Monitoring surface / ground once in a season during Pre-construction period and once in a season during the during the construction period at Intake well, Sump & PH, Filtration Plant/WTP, ELSRs, Pipelines & Distribution network
II. Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5) with Tree Gaurds as per the Technical Specification
III. Sprinkling of water with 5000 Litres capacity tankers once in a day for 600 days (excluding rainy days)
Hiring for 1 Nos. Vehicles for 24 Months during execution period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,
MADAKASIRA NAGARA PANCHAYATH (STP)
Construction of Interception and Diversion works with RCC M25 including drain sidewalls, Weir structure,providing aprons with RCC diversion arrangements,Trash Screening Channels and distribution chamber.
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification 305 MORD/304 MORTH for pipe line trenches by Mechanical Means
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying PCC M-10 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying VRCC M-25 grade design mix cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
RCC Raft for weir work
RCC Raft for Trash Screen Chamber & Distribution Chamber
RCC Wall(200mm thk) for weir, Trash Screen chamber & Distribution Chamber
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe415 / Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Supply Delivery and fixing of SS Trash screen - 0.90 W x 1.20 D as per Technical Specification
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
Designing and Construction of Inlet works consisting of lead channel with isolation gates, mechanical coarse screens+ manual coarse screens, manual grit channel with overflow weir (with one working & one standby) all mechanical and manual screens.
Inlet Works-Mechanical
Providing, supplying, erecting, testing and commissioning of Manual raked coarse bar J-type screen with bar sizing of 50mm wide x 10mm thick and having 20mm clear gap between screen bar of SS 316L with screenings collection trolley. Size 750mm width x 750mm SWD + 500 mm Free Board
Providing, supplying, erecting, testing and commissioning of Mechanical multi rake coarse bar screen with bar sizing of 50mm wide x 10mm thick and having 20mm clear gap between screen bar of SS 316L. Size 750mm width x 750mm SWD + 500 mm Free Board
Providing, supplying, erecting, testing and commissioning of differential level sensor
Providing, supplying, erecting, testing and commisioning of Belt conveyor to transfer screening from mechanical bar screen to screenings collection trolley.
Providing, supplying, erecting, testing and commissioning SS Sluice gate 750mm (W) x 750mm (H)
Providing, supplying, fixing, testing ventilation fans as per specification
Providing and fixing of CO2 type portable fire extinguisher (5 kg)
Providing and fixing of Vent pipe
Inlet works-Civil
Earth work excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying PCC M-10 grade cement concrete using 40 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification.
Laying VRCC M-25 grade design mix cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
RCC Raft
RCC Wall(200mm thk)
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Designing and Construction of Wet Well cum pumping station for a diameter of 5.00m with RCC M25 grade of concrete including aluminum windows, MS shutters and lighting arrangements
Earth work excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Earth work excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Manual Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying VRCC M-30 grade design mix cement concrete using 20 mm m/c HBG down size approved, clean, hard, graded aggregates, OPC cement including cost of all materials, machinery, labour, formwork, scaffolding, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing excluding cost of reinforcement etc., complete and as per Technical Specification
RCC Raft
RCC Wall(300mm thk)
Slab 150mm thick
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe415 / Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Brick Masonry in CM (1:5) with 2nd class Bricks traditional size 23x11x7cms including cost and conveyance of materials to site, mixing of cement mortar and laying of bricks and mortar to specified thickness, watering and curing, scaffolding charges, etc complete for finished item of work and as per Technical Specification
Plastering with CM (1:3), 12 mm thick including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification- Inside Walls
Plastering 20 mm thick Cement Mortar to external & Interior walls in two coats, first coat of 16mm thick in CM (1:4) and 2nd coat of 4mm with dubara sponge finishing including making grooves at columns and beams including cost and conveyance of all materials and water to work site and all operational incidental, labour charges such as scaffolding, mixing mortar lift charges curing etc., complete for finished item of work and as per Technical Specification.- Outside Walls
Painting Walls with Snowcem or other equal and approved Water Proof Cement Paint 2 caots over one coat Priming Coat, total 3 Coats (All Colours) to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc. complete for finished item of work as per Technical Specification for external walls
Supply and fixing of pre-painted steel windows & top hung and fixed louvered ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, section for outer frame of 46 x 52 mm section and for shutter of 46 x 46 mm section for mullion 46 x 70 mm, and section for beading should be 18 x 25 mm and section for louvered ventilation of 33 x 56 mm Box section and the windows panelled with 5 mm thick plain float glass & 4 mm pinhead glass for ventilators with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner brocket centre mullions fixed using mullion cap and with handle made of high grade aluminium powder coated and nylon receiver, corner brackets made of CRCA with Zinc Phosphate, Mullion caps made of glass filled nylon, frames fixed to the concrete /masonry wall by means of self expanding screws including 10 mm square guard bars with 6" pitch complete for finished item of work Technical Specification.
Supply & fixing of Rolling shutter made of 80 x 1.25 mm machine rolled CRCA laths, interlocked together through their entire length and jointed together at the ends by end-locks, mounted on specially designed pipe shaft of 50mm dia nominal bore MS B class pipe with brackets, plates, guide channels, stoppers, bottom locking plates and arrangements for inside & outside locking with push-pull operations including cost of hood cover and springs complete, painted with one coat of approved steel primer, locks, ball bearings, all accessories etc complete for finished item of work as per Technical Specification
Supply and Delivery of Unplasticised PVCs Pipes for potable water supplies conforming to IS : 4985/2000 (3rd revision) with bell ends (Socket) as per specification in light Grey/Natural Ivory Grey/ Any other Color (except White) inclusive of transportation ,labour charges etc., complete and as per Technical Specification-110mm (6 Kgs/cm2)- Rain water & vent Pipe
Supply, transportation & installation of 600mm x 75mm x 2.0mm sizes of Hot Dipped Galvanized Iron perforated cable trays without cover, including horizontal and vertical bends, reducers tees, cross members and other accessories as required and duly suspended from the ceiling/Wall with suspenders etc., complete.
Supply and erection of non-clog submersible pump-sets 5 (2W+2W+1W) at Wet well
Supply, delivery, erection, commissioning and testing of non-clog submersible pump-sets of 2 nos with SS CF8 M Impellar, CI casing, SS 410 shaft suitable for 3 Phase 415V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class F insulation and IP 68 protection. The scope shall include all required accessories viz, auotmatic coupling device, guide pipe, chain with shakle, flat submersible cable upto starter panel through suitable size GI pipe with necessary electrical connection with the starter panel and as per specification. Submersible Pump with suitable motor , inclusive of startup and commissioning spares Solids handling capacity of 50mm at Proposed wet wells ( for 2 DWF of 2.5 MLD with 18m head)
Supply, delivery, erection, commissioning and testing of non-clog submersible pump-sets of 2 nos with SS CF8 M Impellar, CI casing, SS 410 shaft suitable for 3 Phase 415V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class F insulation and IP 68 protection. The scope shall include all required accessories viz, auotmatic coupling device, guide pipe, chain with shakle, flat submersible cable upto starter panel through suitable size GI pipe with necessary electrical connection with the starter panel and as per specification. Submersible Pump with suitable motor , inclusive of startup and commissioning spares Solids handling capacity of 50mm at Proposed wet wells ( for 2 DWF of 5 MLD with 18m head)
Supply, delivery, erection, commissioning and testing of non-clog submersible pump-sets of 2 nos with SS CF8 M Impellar, CI casing, SS 410 shaft suitable for 3 Phase 415V, 50 Hz, AC supply, submersible motor having TEFC enclosure with class F insulation and IP 68 protection. The scope shall include all required accessories viz, auotmatic coupling device, guide pipe, chain with shakle, flat submersible cable upto starter panel through suitable size GI pipe with necessary electrical connection with the starter panel and as per specification. Submersible Pump with suitable motor , inclusive of startup and commissioning spares Solids handling capacity of 50mm at Proposed wet wells ( for 3 DWF of 7.5 MLD with 18m head)
Sewage Treatment Plant for 5.00 MLD @ (any Open Proven Advanced Technology)- Design , Build, Operate and Transfer (DBOT) Method
Designing, providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of 5 MLD STP based on Open Proven Advanced Technology with SCADA and automation and which can be accommodated in limited identified land space consisting of Primary, Secondary and Tertiary Treatment Units as per the requirement of designed CPHEEO norms relevant IS codes etc. and necessary piping work with required DI valves, SS gates, drains, tiled pathways at Ground level, administration block cum Labratory, Labratory Equipments, tools and plants, spare parts, internal roads, Greenary, lighting etc. complete as turnkey job with all involved civil, electrical, instrumentation, furniture, operating and controlling with PLC connected to SCADA for real time monitonring and mechanical works inclusive of following items, units as per detailed specification for civil, electrical, instrumentation and mechanical components with all duties and taxes etc, complete but excluding GST to achive BOD <5 ppm, COD<100ppm, TSS <10ppm , TN< 10 ppm, NH3-N<2ppm and TP <1 ppm) to get recyclable quality of water for industrial /agricultural purpose.
Installation of Real Time Monitoring Systems for online monitoring of treated waste water on the STPs (Excluding GST)
Supply, delivery and Installation of 100 KVA Transformer for Pumpsets of Wet well.
Supply and erection of 7.50m long double pole structure fabricated with 150x75mm RS Joists,100x50mm MS channels, iron cross armstor fuse set and Lighting arrestrors etc.,including one coat of red oxide primer and two coats of bright Supply
Supply and fixing of 11 KV ,400 A 3 phase central post rotating double break type AB switch(isolator) as per IS 9921) without earth blade, gang operated, Horizontal type, operating mechanism with GI spring loaded reverse loop type fixed contact, solid HD electrolytic copper tubular moving contact with silver/Nickel plated at end points,9 Nos post insulators of 12 KV (IS 2594 and IS 5350) ,Hot Dip galvanizing hardware, GI pipe, Nuts and bolts etc., complete., ELEC 6.5.14/MAT 04113
Supply and fixing of 100 A 11 KV Horn Gap fuse set as per IS 9385 on existing DP structure with 6 no of 24 KV /22 KV post Insulators (IS 5350, Hot dipped Hardware, fuse wire of required size etc., complete ELEC 6.5.12/MAT 04111
Supply and fixing of distribution type lightning arrester 11 KV 5 kA as per IS 3070 with mounting base on the existing DP structure ELEC 6.5.11/MAT 04110
Supply and erection of 11KV Strain disc. Insulators with GI pins and top clamps
Supply and fixing of 11 KV pin Insulator (IS 731/1971) with minimum creepage distance of 300 mm on existing cross arm including all accessories like Hot dip GI spindle and nuts etc., ELEC 6.5.8/MAT 04105
Providing jumper connections with I/O' SWG HDBC wire between the 11 KV equipment on the outdoor structures
Supply and erection of GI stay set of dia 16mm,1.8 mtr long stay rod and anchor plate 380mmx380mmx6.4mm. including stay clamps, turn buckle and GI stay wire tight end through strain insulator including excavation of pit and cc work etc., complete ELEC 6.5.3/MAT 04097
Providing efficient earthing arrangement forthe DP structure lighting arresters and the HV equipment. Transformer body and neutral etc., with 25 x 3 mm copper flats and connecting them to the Earth Electrodes fabricated and buried accroding to standard specifications and as per the details given below:
Earth Electrodes
20mm x 3mm Copper Flat(0.529Kgs/1Mtr)
Epoxy insulators
8' SWG Copper wire.
Supply, Transportation, Installation, Testing and Commissioning of 11/0.433 KV TRANSFORMER (100 KVA) with all test reports. The Transformer shall be designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with latest ammended and as per IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per IS 335-1993. The basic details of the Transformer are as under.
1. Quantity : 1
2. Rated KVA : 100 KVA
3. Service & Location: Continuous Outdoor Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40⁰C in oil 45⁰C by resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : ______
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary voltage variation : +5% to - 10% in steps of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the site condition.
b. LV: Cable box suitable to receive ------------Sq.mm XLPE cable
22. LV:One separate terminal for earthing.
23. Total Losses at 50% Loading [Watts] [Max] : 955 Wats
24. Total Losses at 100% Loading [Watts] [Max] : 2750 Wats
25. Percentage Impedance at 75 deg C AT 4.5
26. No load Current Less than 2% of full load Current
27. Standrad Fittings & Accessories.
a. Rating and terminal marking plate: One
b. Lifting Lugs:Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable) :Adequate
f. Explosion vent with Diaphragm :One
g. Conservator with Drain plug:one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silicagel Breather : One
k. Terminal Arrangement: HV With Treminal Box
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Filter valve with blanking plate : One
o. Drain cum filter valve with blanking plate : One
p. Air release device : One
q. Thermometer Pocket : One
r. Four :Unidirectional flat rollers
s. One :10Cm dial thermometer(Rigid stem type)
Supply and laying of 400Sq mm X 3.5 core XLPE insulated, 1100V grade armoured aluminum cable as per specification confirming to IS:7098 (Part- I)./1554-I Makes: Makes: Torent / Universal / Unicab / Havells / Finecab/ KEI / Gloster/ Polycab /RR Kabel/ Fortune Arrt ELEC-4.1.1q MAT-03431
LT Panel
Supply Installation Testing and commissioning of free-standing floor mounted dust and vermin proof compartmentalized cubical panel made out of CRCA sheet, required hardware, cleaning with 7 tank process duly painted by two coats of zinc/red oxide primer followed by Powder coated / epoxy / PU painted with phosphatisation in grey or required shade after rinsing. The panel having PU/ Neoprene rubber gasket of not less than 3mm thickness, separate detachable, gland plate M.S. base channel, hinged door with locking arrangement for equipment/switchgear. The thickness of sheet shall not be less than 1.6mm up to 600mm length/ width of any compartment and be 2.0mm above 600mm. The load bearing structure shall be of 2.0mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartments having bolted type doors with detachable extension type structure (only outer area on all sides shall be measured and panel to be fabricated from CPRI approved fabricator) MAT 03976
Supply and fixing of Electrolytic grade copper bus bar bus bar by means of SMC / DMC type insulator, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves MAT 03978
Incoming
a) 630A TPN SDFU for main switch Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
b) 630A 4pole change over switch Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
c) Supply and fixing of (0-500) V range Voltmeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves /channel etc. as required Digital type Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec MAT 03980
e). Supply and fixing of CT operated direct reading type Ammeter on existing panel, making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required. Digital type Below 500 A Make: Conzerve/Elmeasure/Meco/HPL/L&T/Schneider/AE/Socomec MAT 03983
g).3RYB Phase indication lamps with leds
h).Supply and Fixing of Current Transformer, with all necessary support in existing panel including connection etc. as required from 200 / 5 to 400/5 Ratio, 10 VA, class 1 accuracy: Make: Kappa/L&T/Seimens/C&S/Schneider MAT 03986
Out-Going
630A TPN SDFU forCW pump house motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for compressor/mechanical equipments Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for low lift sump Raw water motors Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for Space Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A TPN SDFU for lighting section Makes:LauritzKnudsen(FormerlyL&T)/Schneider/ C&S/ ABB / SIEMENS MAT 02885
630A 4pole change over switch for lighting section Makes:Socomec/LauritzKnudsen(FormerlyL&T)/HPL / Havells/ C&SMAT MAT 02898
.KWH digital meter fro lighting section
Supply of 32 Amp………ISI marked TPN Switch Disconnector Fuse Unit, Cubical type without fuses as per IS: 13947/IEC 60947-3 Makes: As per list of recommended brands as category I.MAT-02879
Supply of 6A to 35 A……ISI marked HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2 Makes: As per list of recommended brands as category I MAT-02938
Standard duty Single phase 250 V / Three phase 440 V, 50 Hz capacitor (Bank) MAT-03998
1000KV LT/Transformer Errection.testing Commensing and Supply of drawing layout plans of installed transformer in tracing cloth and duly get approved from electrical inspector APEPDCL and leaflets for various equipments and opearation manuals etc., complete.
Supply and Laying of 3C X 35 Sq mm XLPE insulated IS:7098/II/85 H.T. cable for working voltage 11 KV Earthed with Stranded Compacted Circular Aluminium Conductor Screened with Extruded Semi-conducting compound, XLPE Insulated Screened with extruded semi-conducting compound in combination with Copper Tape, cores laid up, inner sheath of Thermoplastic tape, galvanized flat steel strip armoured and overall Extruded PVC Type ST- 2 Outer Sheathed cable etc., complete. Make: Torrent / Universal / Unicab / Havells / KEI/Polycab/Gloster/RR Kabel/RPG MAT 03456
Transformer yard
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification - by manual means
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification For the footings of the Double Pole Structures
Supplying and fixing galvanised steel barbed wire (IS : 278-1962 Type I) weighing 9.38 Kg per 100 metres (min.), Straining and fixing to any type of standard, rails, straining bolts, including securing with and provision of galvanised mild steel wire, stapples or steel pins, etc., as directed by Engineer-in-Charge
Supply,delivery of MS grill gates,window ornamental safety grill, made with MS flats, MS angles, MS squares etc including welding, finishing, applying red oxide paint as primary coat etc complete as per technical specification
Painting with synthetic enamel paints of approved brand in two coats over a one coat of red oxide primer including cost and conveyance of all materials to work site charges and all operational, incidental, labour charges etc. complete for finished item of work as per Technical Specification for gates and grills
Supply and filling of 40 mm size m/c HBG metal (SS5) as per specification and drawing including cost and conveyance of materials to site with all leads, lifts including watering, tamping, ramming, labour charges, all other incidental and operational charges etc., complete as per detailed specification and directed by the Engineer - in - Charge.
Strengthning of Lead drain to Connecting STP @ Hindupur Road
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material as per Technical Specification -ordinary soil--Mechanical Means upto 3m depth for drains and culverts
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Laying insitu VCC M-7.5 grade cement concrete using 40 mm down size m/c HBGapproved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specification for bed concrete
Providing PCC Grade M15 concrete using 20 mm nominal size hard stone aggregate, mechanically mixed, placed in foundation including cost and conveyance of all materials like cement, sand, coarse aggregate, water etc., to site, labour charges, for mixing, laying, concrete, ramming in 15 cm layers, finishing top surface to the required level curing etc., complete for finished item of work complete as per drawings and technical specifications as directed by the Engineer in Charge.
Laying VRCC M-20 grade cement concrete using 20 mm down size approved, clean, hard, graded aggregates, OPC cement for foundation filling including cost of all materials, machinery, labour, formwork, cleaning, batching, mixing, placing in position, levelling, vibrating, finishing, curing etc., complete and as per Technical Specificationfor culvert slabs
Providing High Yield Strength Deformed (HYSD) Thermomechanically treated (TMT) / Steel bars (Fe500 Grade as per IS 1786-1979) of different diameters for RCC works, including labor charges for straightening, cutting, bending to required sizes and shapes, placing in position with cover blocks of approved materials and size and tying & lap-Splicing with biding wire 18 SWG, forming grills for reinforcement work as per approved designs and drawings including cost and conveyance of steel bars including all wastages such as overlaps, couplings, chairs, spacer bars including cost and coveyance binding wire, cover blocks and incidental, operational labor charges such as cutting, bending, placing in position tying as per technical specification.
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
Providening RCC S/S pipe NP-2 Pipe to Carry STP Out Side of Town
Earth work excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Supply and filling with Crusher Stone Dust complying with standard specifications including cost and conveyance of Crusher Stone Dust to site to work labour charges watering tamping, ramming etc complete and as directed by the Engineer-in-Charge of the work
Supply and Delivery of R.C.C. Socket and Spigot pipes conforming to B.I.S. 458/2003 including transportation, taxes & duties and as per Technical Specification and excluding GST "RCC 600 mm NP-2 (Non -Pressure)"
Barricading ,hoarding,lighting and watching etc complete and as per technical Specification for water supply and sewerage works for trenches upto 6 feet-( 2m) below GL
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
Site Improvement works
Earth work excavation in all kinds of soils of foundation of structures as per Technical Specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material by By Mechanical Means.
Collection ,supply and spreading of Sand including compaction and watering as directed by the Engineer-in-Charge
Collection ,supply and spreading of Gravel including compaction and watering as directed by the Engineer-in-Charge
Bailing out water with oil engine driven pumpsets, including hire charges, fuel charges and wages for Driver and Helper and all incidental charges etc., complete and as directed by Engineer-in-charge
KALYANADURGAM MUNICIPALITY
Operation and maintainance for Seven years including Defective Liability Period
Personal required for operating Intake/Offtake well/Pump houses
Operator
Fitter/Helper
Watch man
Personal required at operating Raw water rising mains
Fitter/Helper
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at operating Service reservoirs
Watch man
Consumables
A) Chlorine gas for Disinfection @ 3 mg/Lt
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines.
B) Alumino -Ferric (Alum) @ 20 mg/Lt
Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iv)Replacement of glands of sluice valves
v) Replacements of balls of Air valves
vi) Greease
vii) Gland Packing
LEAKAGES
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged DI Pipe/HDPE for 2 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
110 mm HDPE Pipes
160 mm HDPE Pipes
200 mm HDPE Pipes
250 mm HDPE Pipes
Operation and maintainance for Seven years including Defective Liability Period for LOCAL SCADA at ULB LEVEL
Local SCADA at ULB for 7 years
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Construction of 10 MLD WTP at Akkamma Konda Head Works
600 KL capacity ELSR at NTR Colony with a staging of 21 m - for zone- 1
700 KL capacity ELSR at Grave yard with a staging of 17 m - for zone- 2.
500 KL capacity ELSR at Dhobi Ghat with a staging of 12 m - for zone- 3.
900 KL capacity ELSR at Marampalli with a staging of 17 m - for zone- 4. ( Above GL )
300 KL capacity ELSR at Mudigallu with a staging of 17 m - for zone- 5.
300 KL capacity ELSR at Ontimidde with a staging of 17 m - for zone- 6.
Replacement of necessary tranducers for PH analysers
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Operation and maintainance for Seven years including Defective Liability Period for Cental SCADA
Application Engineer (Graduate Engineer)
Sr. Service Engineer (Graduate Engineer )
Data Operator
Office assistant
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
GOOTY MUNICIPALITY
Operation and Maintenance for the Seven (7) Years including Defect Liability Period-From Source to ELSR's
Personal required for operating Intake/Offtake well/Pump houses
Operator
Fitter/Helper
Watch man
Personal required at operating Raw water rising mains
Fitter/Helper
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at operating Clear water rising mains and Distribution lines
Fitter/Helper
Personal required at operating Service reservoirs
Watch man
Personal required at operating distribution system
Watch man
Consumables
A) Chlorine gas for Disinfection @ 3 mg/Lt
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines.
B) Alumino -Ferric (Alum) @ 20 mg/Lt
Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iv)Replacement of glands of sluice valves
v) Replacements of balls of Air valves
vi) Greease
vii) Gland Packing
Operation and Maintenance for the Seven (7) Years including Defect Liability Period-For Distribution network
Personal required at operating distribution system
Fitter/Helper
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
Monitoring Costs : Operation Phase ( One year)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)
Sprinkling of water once in a day for two years (excluding rainy days):
Local SCADA at ULB for 7 years
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Hiring of vehicle (4 wheeler)
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Clear Water outlet of Water Treatment plant
Inlet of 300 KL Proposed GLBR
Inlet of 700 KL Proposed ELSR
Inlet of 1050 KL Proposed GLSR
Inlet of 900 KLProposed GLSR
Replacement of necessary tranducers for PH analysers
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Central SCADA for ULB for 7 years
Application Engineer (Graduate Engineer) LAB-00130 of CSSR 2025-26
Sr. Service Engineer (Graduate Engineer ) LAB-00130 of CSSR 2025-26
Data Operator LAB-00134 of CSSR 2025-26
Office assistant LAB-00124 of CSSR 2025-26
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
PUTTAPARTHI MUNICIPALITY
Operation and maintainance for Seven years including Defective Liability Period
Personal required for operating Intake/Offtake well/Pump houses
Fitter/Helper
Watch man
Personal required at operating Raw water rising mains
Fitter/Helper
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at operating Clear water rising mains
Fitter/Helper
Personal required at operating Gravity mains
Helpers / Fitters
Personal required at operating Service reservoirs
Watch man
Electrician / Mechanic
Helpers / Fitters
Personal required at operating distribution system
Fitter/Helper
Chemical charges
Chlorine gas ( 3 mg/lit) for disinfection
Alum requirement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iii)Replacement of glands of sluice valves
iv) Replacements of balls of Air valves
v) Greease
vi) Gland Packing
LEAKAGES
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
250 mm HDPE Pipes
200 mm HDPE Pipes
160 mm HDPE Pipes
110 mm HDPE Pipes
Local SCADA at ULB for 7 years
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Clear Water outlet of Water Treatment plant
Inlet of 500 KL Proposed GLSR at Beedupalli
Inlet of 500 KL Proposed ELSR at Prasanthi Gramam
Inlet of 500KL Proposed ELSR at Bramhanapalli Thanda
Inlet of 1500 KL Existing ELSR at Yenumalapalli
Inlet of 1200 KL Proposed GLSR at Peddakammavari palli
Inlet of 300 KL Proposed ELSR at Chitravathi gutta
Inlet of 300 KL Proposed ELSR at Karnataka nage palli
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Application Engineer (Graduate Engineer)
Sr. Service Engineer (Graduate Engineer )
Data Operator
Office assistant
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
MADAKASIRA NAGARA PANCHAYATH
Operation and Maintenance for 7 years
Personal required for operating Intake/Offtake well/Pump houses
Fitter/Helper
Watch man
Personal required at operating Raw water rising mains
Fitter/Helper
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at operating Clear water rising mains
Fitter/Helper
Personal required at operating Gravity mains
Helpers / Fitters
Personal required at operating Service reservoirs
Watch man
Electrician / Mechanic
Helpers / Fitters
Personal required at operating distribution system
Fitter/Helper
Consumables
A) Chlorine gas for Disinfection @ 3 mg/Lt
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines.
B) Alumino -Ferric (Alum)
Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iv)Replacement of glands of sluice valves
v) Replacements of balls of Air valves
vi) Greease
vii) Gland Packing
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
250 mm HDPE Pipes
200 mm HDPE Pipes
160 mm HDPE Pipes
110 mm HDPE Pipes
Monitoring Costs : Operation Phase ( One year)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground (5 Monitoring station) once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)
Sprinkling of water once in a day for two years (excluding rainy days):
LOCAL SCADA at ULB LEVEL
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Hiring for 1 Nos. Vehicles for during O&M period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Clear Water outlet of Water Treatment plant
Inlet of 300 KL Proposed GLSR at Begarlapalli
Inlet of 250 KL Proposed ELSR at Gollahatti
Inlet of 200KL Proposed ELSR at Maruthi nagar
Inlet of 700 KL Existing ELSR at Govt Jr college
Inlet of 600 KL Proposed ELSR at Boyagiri
Inlet of 300 KL Existing ELSR at Mallikayanapalli
Inlet of 500 KL Existing ELSR at New SC colony
Replacement of necessary tranducers for PH analysers
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Central SCADA for ULB for 7 years
Application Engineer (Graduate Engineer)
Sr. Service Engineer (Graduate Engineer )
Data Operator
Office assistant
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
GUDUR NAGARA PANCHAYATH
Manning, Operation and Maintenance of Water Supply Improvement Scheme for 7 years.
Personal required for operating Intake / Offtake well / Pump houses.
Operator
Fitter/Helper
Watch man
Personal required at operating Raw water rising mains.
Fitter/Helper
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at Service reservoirs
Watch man
Personal required at operating distribution system
Fitter/Helper
Consumables
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines.
Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iv)Replacement of glands of sluice valves
v) Replacements of balls of Air valves
vi) Greease
vii) Gland Packing
LEAKAGES
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
250 mm HDPE Pipes
200 mm HDPE Pipes
160 mm HDPE Pipes
110 mm HDPE Pipes
Monitoring Costs : Operation Phase ( One year)
Air Quality Monitoring once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Noise level once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Water Quality Monitoring surface / ground once in a month for three seasons during the construction period at intake well, Filtration Plant/WTP, ELSR's, Raw/Clear Pipe Line & Distribution network
Compensatory plantation and three years maintenance (Compensatory afforestation ratio is 1:5)
Sprinkling of water once in a day for two years (excluding rainy days): 500 days @ Rs.1000/trip
LOCAL SCADA at ULB LEVEL
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Hiring for 1 Nos. Vehicles during O&M period including hire charges of vehicle, diesel, lubrication, driver charges, repairs and all incidental charges etc.,
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Clear Water outlet of Water Treatment plant
Inlet of 200 KL Proposed GLBR
Inlet of 600 KL Proposed ELSR
Inlet of 700 KL Proposed ELSR
Inlet of 600 KL Proposed ELSR
Replacement of necessary tranducers for PH analysers
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Central SCADA for ULB for 7 years
Application Engineer (Graduate Engineer)
Sr. Service Engineer (Graduate Engineer )
Data Operator
Office assistant
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
YERRAGUNTLA NAGARA PANCHAYATH
Operation and maintainance for Seven years including Defective Liability Period
Personal required for operating Intake / Offtake well / Pump houses.
Operator
Fitter/Helper
Watch man
Personal required at operating Water treatment plants & Sump
Operator
Fitter/Helper
Lab Technician
Electrician /Mechanic
Watch man
Personal required at operating Gravity mains
Watch man
Personal required at operating Service reservoirs
Watch man
Personal required at operating distribution system
Fitter/Helper
Consumables
A) Chlorine gas for Disinfection @ 3 mg/Lt
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines.
B) Alumino -Ferric (Alum)
Supply and delivery of Alumino -Ferric (Alum) as per IS standards including the cost of material, conveyance, stacking at the location specified by the Dept., and including all taxes except GST etc., complete.rement at 15 mg/lit
Repairs to pumpsets & Water pipe lines (2 years after execution period)
i) Replacement of bearings of pumpsets
ii) Replacement of sleeves
iv)Replacement of glands of sluice valves
v) Replacements of balls of Air valves
vi) Greease
vii) Gland Packing
LEAKAGES
Earth work Excavation,Bailing out water from Pipe Line Trench and replacement damaged HDPE Pipe for 1 M length including the Cost of Pipe Collar M/F Joint and refilling etc complete
200 mm HDPE Pipes
160 mm HDPE Pipes
110 mm HDPE Pipes
Local SCADA at ULB for 7 years
Jr. Service Engineer (Diploma Engineer)
Data Operator
Office assistant
Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets. Replacement of necessary servicable materials(Reagents) for Chlorine Analysers * Each Reagent bottle will work for 90 days (Self life) as per the Caluculation based on the Sampling interval in every 10 Minuets.
Clear Water outlet of Water Treatment plant
Inlet of 615 KL Proposed GLBR at Gandikota
Inlet of 750 KL Proposed 750 KL capacity ELSR @ Zone - 1
Inlet of 1000 KL Proposed 1000 KL capacity ELSR @ Zone - 1
Inlet of 600 KL Proposed 600 KL capacity ELSR @ Zone - 1
Inlet of 90 KL Existing ELSR at Vinayaka Nagar
Inlet of 400 KL Existing ELSR at Ranivanam
Inlet of 150 KL Existing in old municipal office
Replacement of necessary tranducers for PH analysers
Clear Water outlet of Water Treatment plant
Replacement of necessary tranducers for Turbidity analysers
Clear Water outlet of Water Treatment plant
BSNL Charges for static IP,(Interconnection for Data receive station from all Local Contol RTU panels.)
GPRS Connections (Data transfer from RTU control panels)
WTP Quality Management (Data transfer from RTU control panels)
ELSR Management (Data transfer from RTU control panels)
DMA Management (Data transfer from RTU control panels)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
Central SCADA for ULB for 7 years
Application Engineer (Graduate Engineer)
Sr. Service Engineer (Graduate Engineer )
Data Operator
Office assistant
BSNL Charges for static IP (nterconnection for Data receive station from all Local Contol RTU panels.)
Data base management for WEB reporting (Data storage and reporting system for view through WEB and Mobile networks)
Charges for maintainance of PC's, Hardware consumables, Minor repair & Servers ,servomax Stabliser, UPS, maintainance of entire system including cost and convayance of all material and labor and attending minor repairs to instrumantation and automation equipment etc., complete
MADAKASIRA NAGARA PANCHAYATH-STP
O &M charges for 7 years( to be met from ULB funds)
Personal required for operating proposed STP for 7 years
Diploma Engineer-Electrical (1 No.)
ITI Qulified Electrician (1 No.)
ITI Qulified Plumber (1 No.)
Semi sikeed laboures (2 No.)
Unskilled Labour (4 No.)
Watch man& Security (4 No.)
Computer Operator (1 No.)
Laboratory Assistant / Chemist (1 No.)
Chemical charges for 5.00 MLD STP for 7 year
Supply, delivery and stacking of Chorine gas as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines. for disinfection 3 mg/lit
Supply, delivery and stacking of Dewatering Polyelectrilyte as per relevant indian standards in cylinders including cost of material, coveyance, stacking at the location specified by the Department and inclusive of all taxes except GST etc., complete to be used as a disinfectant in accordance with CPHEEO manual guidelines. Dewatering Polyelectrilyte @ .3mg/lit
Disposal of Sludge from STP for 7 years
Hiring of Tractor for Disposal of Sludge & Floating matter from STP once in a week(8 hours per day & 52 days in a year)
Tractor Driver once in a week
Repairs to Civil Works, Electrical & Mechanical Works for 7 years
Repairs to all Civil Works (1 Job/ Year)
Repairs to all Electrical & Mechanical Works (1 Job/ Year)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_1.pdf
PDF • 0.48 MB
AD.rar
Additional Documents • 20.76 MB
AD1.rar
Additional Documents • 20.58 MB
AD2.rar
Additional Documents • 21.88 MB
BOQ_921447.xls
BOQ • 5.19 MB
TenderDocument.rar
Tender Documents • 5.22 MB
CorrigendumII.pdf
PDF • 0.38 MB
Table_2PreBidAmendments.pdf
PDF • 0.60 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .