| 1 | L1₹22.6 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | ₹22.6 L Quoted ₹23.2 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹23.4 L+₹14,195 (0.61%)Rejected-Finance NEAR RAILWAY STATION UTARLAI BARMER RAJASTHAN PIN 344001 | BARMER | RAJASTHAN | 344001 | ₹23.4 L+₹14,195 (0.61%) | L2 | Rejected-Finance Rejected being L2 |
| 3 | L3₹24.8 L+₹1.6 L (6.78%)Rejected-Finance | ₹24.8 L+₹1.6 L (6.78%) | L3 | Rejected-Finance Rejected being L3 |
| 4 | L4₹25.0 L+₹1.8 L (7.79%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹25.0 L+₹1.8 L (7.79%) | L4 | Rejected-Finance Rejected being L4 |
| 5 | L5₹28.6 L+₹5.4 L (23.4%)Rejected-Finance V PO RAIKO KI DHANI NAWAJI KA PANA BHURTIYA DISTT BARMER RAJ PIN 344001 | BARMER | RAJASTHAN | 344001 | ₹28.6 L+₹5.4 L (23.4%) | L5 | Rejected-Finance Rejected being L5 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
17 Apr 2021, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR/REPLACEMENT OF CERTAIN INTERNAL ELECTRIFICATION WORKS AT DARJIPURA AF STATION BARODA
2021_MES_427649_2
8554/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹48,000
Yes
8 Jun 2021
1 Apr 2021
20 Apr 2021
1 Apr 2021
17 Apr 2021
3 Apr 2021
Amount
Taking down carefully copper / Aluminium point wiring (light, fan, socket or power complete) including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc and removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
Taking down carefully unserviceable main switches and DB's including MCBs of any size any type complete all as specified and directed.
M/L for Point wiring complete with 1.5 sqmm single core PVC insulated and PVC unsheathed (FRLS) multistranded copper conductor cable 1100 volt grade enclosed in and including PVC casing and capping with accessories fixed on surface on walls/ceiling by means of PVC sleeves Dash fastners and cadmium plated screws all as per ISI including sunk type boxes for mounting fitting like switches, socketes fan regulators with 3 mm thick phenolic Laminated sheet top covers concealed in walls etc including 1.5 Sqmm single core multi stranded copper conductor FRLS PVC insulated and unsheathed cable as earth continuity conductor connected to common earth dolly complete all as specified and directed for the follwong :-
One light point controlled by one one/way switch.
One Fan point controlled by one one/way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board.
One bell point controlled by one way switch/bell push
One light point controlled by two, two way switches
Description all as per item No.3.00 above but point wiring with 2.5 sqmm multistranded copper conductor (FRLS) unsheathed cable and 1.5 sqmm copper conductor (FRLS) unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Description all as per item No.3.00 above but point wiring with 4 sqmm multistranded copper conductor (FRLS) unsheathed cable and 2.5 sqmm copper conductor (FRLS) unsheathed cable as earth continuity conductor for one AC socket.
Taking down existing sub main wiring and M & L for new sub main wiring using two single core 6 Sqmm (FRLS) PVC isnulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC casing caping/PVC Conduit with accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 4 Sqmm earth wire, (FRLS) PVC insulated & unsheathed complete all as specified and directed Note: (i) Two runs of 6 sqmm and one run of 4 sqmm cable and one run of PVC casing caping/ conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
Taking down existing sub main wiring and M & L for new sub main wiring using two single core 4 Sqmm (FRLS) PVC isnulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawing in and including PVC casing caping/PVC Conduit with accessories like bends, tee, etc fixed on wall and ceiling and connecting to earth dolly and including 2.5 Sqmm earth wire, (FRLS) PVC insulated & unsheathed complete all as specified and directed Note: (i) Two runs of 4 sqmm and one run of 2.5 sqmm cable and one run of PVC casing caping/ conduit shall be measured as one RM. (ii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted .
S&F 5 Amps Socket outlet, 3 Pin flush type complete all as specified and directed.
S&F 15 Amps Socket outlet 3 Pin flush type complete all as specified and directed.
S&F 15 Amps Switch piano flush type complete all as specified and directed.
S&F ceiling rose surface bakelite 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.
S&F switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed.
S&F switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed.
Supply and fix Stepped/socket type electronic fan regulator heavy duty type, A/C 240 V complete all as specified and directed.
S&F Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.
S&F in replacement 5 Amps Socket outlet 3 Pin flush type complete all as specified and directed.
S&F in replacement 15 Amps Socket outlet 3 Pin flush type complete all as specified and directed.
S&F in replacement 15 Amps Switch flush type complete all as specified and directed.
S&F in replacement switch socket combination 2 in 1, 3 pin, 5 and 15 Amps flush type universal 240 Volt. complete all as specified and directed.
S&F in replacement switch socket 3 pin 16 Amp flush type complete all as specified and directed.
S&F in replacement switch piano flush type single pole one way 5 Amp 240 Volts complete all as specified and directed.
S&F in replacement switch piano flush type single pole two way 5 Amp 240 Volts complete all as specified and directed.
S&F in replacement switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt. complete all as specified and directed.
S&F in replacement modular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular switch one way 16 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular bell push 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular socket outlet 6A 3 pin 2 module 240 Volts. complete all as specified and directed.
S&F in replacement modular socket outlet 6A/16A 5 pin 2 module 240 Volts complete all as specified and directed.
S&F in replacement modular fan regulator 120W-2 module 240 Volts complete all as specified and directed.
S&F in replacement Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.
Supply and fix in replacement Bell ding dong type, one way, 240 volts, AC, ISI marked complete all as specified and directed.
S&F in replacement ceiling rose surface bakelite 65 x 50 mm three terminal 250/230 volts ISI marked complete all as specified and directed.
Supply and fix in repairs Stepped/socket type electronic fan regulator heavy duty type, A/C 240 V complete all as specified and directed.
Supply and fix in replacement LED Tubelight fitting ENERGY Efficient 20 Watt 2000 lumen bright light with 25000 burning hours complete all as specified and directed.
Supply and fix in repairs spot/bar light small type with choke type as Per Sample complete all as specified and directed. Make : Philips(Tornado) / CG.
Supply and fixing in repairs LED light fitting ENERGY Efficient 10 Watt 2 feet 1000 lumen bright light with 25000 burning hours complete all as specified and directed.
S&F in repairs LED wall/recess/ flux light fitting 36 watt, 2x2 square fitting any type of complete all as specified and directed. Make :- CAT No LTCRP36WLED 2x2 of C & S or equivalent make mentioned in Appx B
S&F in repairs LED bulb Lamp 09 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat sink complete all as specified and directed.
S&F TPN DBs Vertical type 4 way DB 415 volt with provision for FP as incomer and SP as outgoing, IP 43-IK 09 with metal door complete all as specified and directed. Make :- CAT No. 6077 51 of Legrand or equivalent make mentioned in Appx 'B'. Note : MCB's will be measured and paid seprately under respective items.
S&F sheet metal enclosure for single pole and neutral 12 way DB 240 volts, 100 Amp rated bus bar, IP 43 - IK -09 complete all as specified and directed. Make :- CAT No. 6077 12 of Legrand or equivalent make mentioned in Appx 'B'.
S&F sheet metal enclosure for single pole and neutral 08 way DB 240 volts, 100 Amp rated bus bar, IP 43 - IK -09 complete all as specified and directed. Make :- CAT No. 6077 11 of Legrand or equivalent make mentioned in Appx 'B'.
S&F sheet metal enclosure for single pole and neutral 04 way DB 240 volts, 100 Amp rated bus bar, IP 43 - IK -09 complete all as specified and directed. Make :- CAT No. 6077 10 of Legrand or equivalent make mentioned in Appx 'B'.
S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one MCB SP 20 Amps complete all as specified and directed.
S&F in repairs MCB's of MCB SP up to 40 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 complete all as specified and directed.
S&F in repair MCB SP &N up to 63 Amp 240 Volts complete all as specified and directed.
S&F in repair MCB TP &N (4P) up to 100 Amp 240 Volts complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit of depth not less than 2.25m deep below normal ground level) with top edge of earth plate at depth not less than 1.5m below ground level, connected to galvanised earth lead wire 4.0 mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 3 of SSR Part-I. Connected to earthing test point all as specified and including necessary earth pit, PCC 1:3:6 chamber, 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement at 10 cm c/c spacing in both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 15mm dia upto 7.5 from the earth plate electrode etc including necessary excavation & earth work in any strata and demolition of old and unservicable existing earth pit complete all as specified and directed.
Supply and fixing in replacement capacitor of 2.5 MFD suitable for any type & sweep of ceiling fan, exhaust fan, cabin fan & pedestal fan complete all as specified and directed.
Supply and fix in repairs Hylum sheet of sutiable Size 3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed. Make :- Anchor or as per sample.
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
Description all as per serial item No. 51.00 above but of size 175x100x50 mm deep
Description all as per serial item No. 51.00 above but of size 200x150x50 mm deep
Description allas per serial item No. 51.00 above but of size 250x200x50 mm deep
Description all as per serial item No. 51.00 above but of size 350x200x50 mm deep
Supply and fixing in repair st right/Angle bulb holder PVC body complete all as specified and directed. Make: Anchor, kolors
M & L for strip opening and removal of burnt winding wire of ceiling fans 1200/1400mm sweep, rewinding the fans with suitable size of copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc including replacing capacitor and bearing with new one complete and reassembling and refixing at site and testing complete all as directed. Note: Rewinding work and replacement of bearing to be carried out at power house at AFS Darjipura only in exceptional case where lathe work is required then only fan to be taken at workshop. Rate quoted is deemed to include for the same.
Description all as per serial item No. 57.00 above but for exhaust fan of any size
Description all as per serial item No. 57.00 above but for cabin fan any size
Description all as per serial item No. 57.00 above but for air circulator fan of any size
Taking down and refixing after repairs storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25/50 ltrs of any type and make, checking the serviceablity of all parts such as inner vessel, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly complete and installing and testing the same as per the direction of Engineer-In-Charge.
S& F in replacement heating elements, 1.5/2KW any type any size ISI mark 230 volts complete all as directed. Make -THEETA/Hotmax
S& F in replacement thermostat immersion point type 15 Amps, 230250 volts/AC ISI marked complete all as directed. Make - THEETA/BAJAJ.
S& F in replacement PVC flexible conneciton pipe with brass check nuts complete all as directed.
S& F in replacement indicator lamp assembly for geyser complete all as specified and directed by Engr-In-Charge.
S& F in replacement 15 Amp plug top complete all as directed.
Supply and fixing in repairs earth industrial plug top for socket for industrial socket metal glad suitable for 20 Amps metal glad MCB DB complete all as specified and directed.
Supply and fixing in repairs earth industrial socket metal glad suitable for 20 Amps 240 volts metal glad MCB DB complete all as specified and directed.
Supply only FR electrical insulation tape nominal size 0.125mm thickness x1.8 cm width x15 mtr length confirming to IS CODE 1728 As per sample complete all as directed.
Supply and fix in repair burnt Energy meter digital type tamper proof single phase 2 wire 10-60A, 240Volts Class 1 complete all as specified and directed. Make :- L&T, Secure, Havells, HPL
Taking down ceiling fan/exhaust fan of any size and any type and cleaning all dust/dert etc and apply two coat of spray painting with white synthetic enamel paint including filling cavities with fine finishing surface by filler one coat complete all as specfied and directed by Engr in charge. Note :- Rate quoted is deemed to include for marking/ numbering MES No/Qtr no. No extra payment should be made for marking/numbering.
M/S TANUSHREE CONSTRUCTION COMPANY
motwani and associate
M/s SK Traders
M/s Malinath Electricals
DARSHAN CONSTRUCTION Co.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .