Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.9 LAccepted-AOC CHANDMARI WARD NO 19 PO PS TEZPUR DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹43.9 L+₹2.9 L (7.06%)Rejected-Finance C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | L2 | Rejected-Finance Become L2 | |
| 3 | L3₹44.2 L+₹3.2 L (7.80%)Rejected-Finance | L3 | Rejected-Finance Become L3 | |
| 4 | L4₹44.2 L+₹3.2 L (7.90%)Rejected-Finance | L4 | Rejected-Finance Become L4 | |
| 5 | L5₹45.1 L+₹4.2 L (10.1%)Rejected-Finance HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L5 | Rejected-Finance Become L5 |
Tender Value
Refer Docs
EMD Value
₹86,600
Closing Date
8 Aug 2022, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur, Assam
SPL REPAIR TO LT OVERHEAD TO UG CABLE IN ZONE 4 AND PROVN OF PREPAID ENERGY METES FOR ZONE 1A, ZONE 4 AND 5 AT SAA UNDER GE (S) TEZPUR
2022_MES_539285_1
8683
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹86,600
Yes
28 Sept 2022
19 Jul 2022
10 Aug 2022
19 Jul 2022
8 Aug 2022
2 Aug 2022
Amount
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.5 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate.
Supply,Laying ,testing, and commissioning size 4 x 25 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade, in tranches / fixing on wall by saddel/ fixing on poll / drawn through GI pipes all as specified and directed.
Supply,Laying ,testing, and commissioning size 3.5 x 150 sqmm cross-sectional area XLPE insulated, screened, PVC bedded, galvanised steel strip armoured heavy duty electric cable with aluminium conductor 1100 volts grade, in tranches / fixing on wall by saddel/ fixing on poll / drawn through GI pipes all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc and 1.5 mtr in depth getting out in in soft/loose soil all as specified and directed by Engineer-in-charge.
Returning and filling including spreading, leveling, watering and well ramming in layer n.exc 25 CM thick in soft/loose soil all as specified and directed by Engineer-in-charge.
Removing excavated material to a distance not exc. 50 mtrs and deposting where directed at a level not exceeding 1.50mm above the starting point all as specified and directed by Engineer-in-charge.
Supply and laying natural river sand as cushioning of cables, including spreading and punning down all as per clause No 3.21 of SSR part -I complete all as specified and directed by Engineer-in-charge and directed by Engineer in charge Note : punned thickness will only be measured for payment purpose.
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge.
Dismantling ACSR conductor including pin/shackle insulators, channels etc complete all as specified and directed.
M & L for boring road or path horizontally for crossing of cable of any type complete all as specified.
Supply and fix GI pipe of dia 80mm to wall/Pole/ buried under ground of medium grade with required clamping arrangements to fix with the pole or buried underground complete and connecting to the existing pipe line all as specified
M&L for fabrication, installation, commissioning and testing of 415 Volt, 3 Phase, 4 Wire system LT Feeder Pillar Box Size 0.6 mtrs x 0.6 mtrs x 0.6 mtrs cubical, Kiosk and Outdoor type having double door with front and back openable made of 3.15 mm thick CRCA sheet and shall be folded and braced as necessary to provide a rigid support for all components and 2.0 mm thick CRCA sheet for inner sheet , provided with handle, locking arrangement 2 Keys ( Godrej Type) , based on suitable size of MS angle 50 x 50 x 6 mm angle iron channel complete to accomodate moulded case circuit breakers, meters, including , 200 Amps single insulated bus bars for R-Y-B-N with heat shrinkable PVC sleeve in suitable bus chambers, interconnection, required lugs of suitable size, copper cable for wiring , name plate, danger plate, with independent compartment for busbars with hinged door for each outgoing/ incoming feeders & its accessories, cable alley with hinged doors, bus chamber with bolted door, dust & vermin proof construction with rubber gasket, powder coating including numbering and lettering mounted on 'U' channel of suitable size over PCC platform must be 0.5 mts from GL of appropriate size etc. Necessary holes shall be kept on the kiosk box for incoming and outgoing cable entry . All holes shall be provided with new brass cable gland of appropriate etc complete in all respects as specified and directed comprising compartments with necessary arrangements for following items :- 1. 100 Amps MCCB Manual type -01 nos incoming 2. 200 Amps Bus Bar chamber R-Y-B-N 3. 20-100 Amps MCCB TPN -02 nos NOTE :- all types of MCCBs will be paid under separate Items
Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2, Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-chargend
Supply and fix MCCB 4 pole, thermal magnetic based Release range 80 Amps to 100 Amps,415V,AC,50Hz ,36 KA Rotary versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.8 - 1.0 x In ,Adjustable Short Circuit setting: 6- 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-chargend
Supply and fix MCCB 4 pole, Microprocessor based Release range 25 Amps to 63 Amps,415V,AC,50Hz ,36 KA Rotary versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.8 - 1.0 x In ,Adjustable Short Circuit setting: 6 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down MCCB all as specified and directed by Engineer-in-chargend
S & F PVC pole mounted loop in loop out box 210 x 310 x 116 mm made of impact assistance plastic and heat resistance material including 01 No 06A SP MCB, 04 Nos 100A rating bus bar mounted on insulators and all cable fixed with suitable lugs and suitable Cable Glands complete all as specified and as directed. Note : (a) Materials for fixing like MS clamps, nuts, bolts & washers are measured & paid separately under item No-6 as Supply Only. (b) labour for fixing of MS clamps, nuts & bolts shall deemed to be included in unit rates. (c) Unit rate shall include the connection between existing incoming LT cable lines to new junction box . Make for loop in loop out box :
M&L 3 core 1.5 sqmm copper conductor cable from junction box to street light through External PVC conduit with necessary clamps complete all as specified and directed.
Supply and Fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for 25x15cm size complete all as specified and directed.
S & F LT Cable root indicator including painting complete all as specified and directed.
Supply, installation, testing & commissioning as in replacement of Single phase, 2 wire, single source, direct connected prepaid key pad based BIS Marked IS-15884 Digital Energy Meter, 10-60 Amps, 240 Volts, accuracy class-1.0 alongwith parallel Consumer Interface Unit and Soft Token Transfer Device at houses, with Poly Carbonate meter box with facility of meter to generate ABC Code ( Authenticated Billing Code) for Monthly Energy usage Bill Generation,having LCD type display, calliberation LED, numeric key pad for token entry with RS 232 communication port, LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load than permissible limit, reconnection and disconnection of load, buzzer at Consumer Interface Unit to give alarm in case of low credit and overloading and data download port for last 25 days (min) temper event and load survey for last 45 days with all standard anti temper features including sealing facility with three years compressive warranty all as specified and directed by Engr-in charge. Make - HPL cat part No. PTPB1521130000OC01 or equivalent in L&T/Siemens/Havells India Ltd./ Schnieder Note:- Cost of connecting to existing system and other connected items including 2 pair, 0.5 mm Annealed Cu connecting wire to connection between meter and consumer interface unit, termination connector for 3 pair wire meter and CIU each set and cost of disconnetion of old existing meters of any size and deposit at E/M store shall deemed to be included in the quoted rate.
Transaction charges to be paid in advance for recharge transactions (3 years charges) for Energy meters without mobile app, complete all as specified and directed.
Supply and fixing 2 Pair Annealed Copper wire of size 0.5 Sq mm to connect between Meter and consumer Interface Unit complete all as specified. Note 1:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embosed with contractor's firm name while carriying out any activities in defence area for better check of security purpose. Note 3:-The tenderer (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
M/S Jiban Krishan Das and Co
M/S Manjit Singh
DRISTEE ASSOCIATES
M/S BHAGWATI CONSTRUCTION CO.
D G Corporation
M/S N S CONSTRUCTION
M/S Deep-Jeet
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .