Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC 338 PRABHAT NAGAR NANDRI BANAR ROAD JODHPUR 342001 JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹13.0 L+₹2.1 L (19.8%)Rejected-Finance 102 VYAS COLONY NEAR AIR FORCE JODHPUR 342011 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342011 | L2 | Rejected-Finance Rejected being L2 | |
| 3 | L3₹13.5 L+₹2.7 L (24.5%)Rejected-Finance 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L3 | Rejected-Finance Rejected being L3 | |
| 4 | L4₹13.9 L+₹3.1 L (28.8%)Rejected-Finance | L4 | Rejected-Finance Rejected being L4 | |
| 5 | L5₹15.5 L+₹4.6 L (42.8%)Rejected-Finance | L5 | Rejected-Finance Rejected being L5 |
Tender Value
Refer Docs
EMD Value
₹36,000
Closing Date
18 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
DAY TO DAY MAINT COMPLAINTS PERTAINING TO EM WORKS OF AGE BR II AREA UNDER GE ARMY CENTRAL JODHPUR (9041/E8)
2021_MES_474572_3
GE/J/A- OF 2021-22 (9041/E8)
Open Tender
Civil Works
Item Rate
180 days
GE (A) Central Multan Line Army Area Jodhpur
DAY TO DAY MAINT COMPLAINTS PERTAINING TO EM WORKS OF AGE BR II AREA UNDER GE ARMY CENTRAL JODHPUR (9041/E8)
6 documents required · 6 mandatory
₹500
GE (A) Central Jodhpur
₹36,000
1 Feb 2022
26 Nov 2021
20 Dec 2021
26 Nov 2021
18 Dec 2021
3 Dec 2021
60 days
Amount
M&L for Attending daily complaints of Jodhpur Mil area by deputing adequate minimum number (Electrician: 01 , Helpers: 01) of teams of qualified Electrician and helper (round the colck) for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system such as switches / sockets / distribution boards / MCB / light / power / lamp holders-bracket / pendent / batten / bell / buzzer / push button / ceiling rose / capacitors and other similar light & power plug, including provisioning of small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 6 Sqmm single core and length not increasing 0.50 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill)., complete all as specified and as directed. Note:- (i) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis (ii) This item pertains to attending complaints of light / fan / power point / MCB / DB including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge. (iii) Other Items shall be measured and paid if reqd to be replaced under respective item of BOQ
M&L to attend major/ minor fault/ No Light due to any reason like neutreal fail or short cicuit complete including petroling or rectfication of complaint etc, complete all as specified and as directed.
S&F electronic adapoter for LED light up to 30 watt as per sample, complete all as specified and as directed. Make: CG or equivalent in Havells/Bajaj/Philips.
S&F in repair, switch piano flush type 6 amp single pole one way 230 V, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, switch piano flush type 6 amp single pole two way 230 V, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, switch piano flush type 16 amp single pole one way 230 V, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, bell push AC, 230 Volts, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, socket out let flush type 3/6 pin suitable for 16 Amp plug top multipurpose 230 V, complete all as specified and as directed. Make : Havell's/ Anchor /Legrand/ABB
S&F in repair, bell AC 230 volts, complete all as specified and as directed. Make: Havell's/ Anchor /Legrand/ABB
S&F in repair, fan regulator electronic switch/ socket type, complete all as specified and as directed. Make: Havell's/ Anchor /Legrand/ABB
S&F in repair, lamp holder insulated body with back plate batten/angle type for batten fittings, complete all as specified and as directed. Make: Havell's/ Anchor /Legrand/ABB
S&F in repair, fan capacitor 2.5 Mfd for ceiling Fan, complete all as specified and as directed. Make: Havell's/ Anchor /Bajaj
S&F in repair, fan capacitor 4 Mfd for Exhaust Fan, complete all as specified and as directed. Make: Havell's/ Anchor /Bajaj
S&F in ceiling rose 3 terminals, complete all as specified and as directed. Make: Havell's/ Anchor /Legrand/ABB
S&F in repair, Modular switch 6 amp one way 230 V , complete all as specified and as directed. Make: Legrand /ABB/Anchor.
S&F in repair, Modular switch 16 amp one way 230 V, complete all as specified and as directed. Make: Legrand /ABB/Anchor.
S&F in repair, Modular socket 6 amp 5 Pin one way 230 V, complete all as specified and as directed. Make: Legrand/ABB/Anchor.
S&F in repair, Modular socket 16 amp 5 Pin one way 230 V , complete all as specified and as directed. Make: Legrand/ABB/Anchor.
S&F in repair, Modular fan Regulator step type 100 watt , 230 Volts, complete all as specified and as directed. Make : Legrand/ABB/Anchor.
S&F in repair, modular cover plate with frame 4 module type for fixing of modular switch socket, regulators, blank plates etc, complete all as specified and as directed.
S&F in repair, modular cover plate with frame 8 module type including cutting of walls PCC work etc, complete all as specified and as directed.
S&F in repair, modular cover plate with frame 12 module type including cutting of walls PCC work etc, complete all as specified and as directed.
S&F in repair, poly carbonate transparent energy meter protection cover temper proof suitable for single phase energy meter etc, complete all as specified and as directed.
S&F in repair, PVC conduit 20/25mm ISI (MMS)grade, complete all as specified and as directed. Make : Polycab/Plaza/Kalinga
S&F in repair, PVC casing Caping 25/32mm ISI (MMS), complete all as specified and as directed. Make : Polycab/Plaza/Kalinga
Taking down ceiling fan for greasing/oiling and refixing the same and connecting up including provision of cable from ceiling rose or connector to fan, complete all as directed.
Taking down exhaust fan for greasing/ oiling and cleaning and refixing and connecting up including provision of cable from ceiling rose/connector to fan, complete all as directed.
S&F in repair, sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-42 DB's suitable for one MCB SPN as incoming and 2 MCB SP as out going,SPN 4Way, complete all as specified and as directed by Engr-in-charge. Make :Havells/Legrand/ABB
S&F in repair, sheet metal enclosures 240 volt with suitable rated bus bar for double door IP-43 DB's suitable for one MCB SPN as incoming and 6 MCB SP as out going SPN 8 way complete all as specified and directed by Engr-in-charge. Make :Havells/Legrand/ABB
S&F in repair, sheet metal enclosures 415 volt TPN 4 way with 200 Amp rated bus bar, double door IP-43 DB's suitable for With 01 nos 4 pole MCCB, 100 Amp, 10 KA rupturing capacity as incoming, complete all as specified and as directed by Engr-in-charge. Make :Havells/Legrand/ABB
S&F in repair, MCB Single pole"C" series 5-32 Amps (ISI marked), complete all as specified and as directed. Make :Havells/Legrand/ABB
S&F in repair, MCB Single pole & neutral "C" series 40 Amps (ISI marked), complete all as specified and as directed. Make :Havells/Legrand/ABB
S&F in repair, MCB Single pole & neutral "C" series 63. Amps (ISI marked), complete all as specified and as directed. Make :Havells/Legrand/ABB
S&F in repair, MCB TPN 'C' Curve 63 Amps, complete all as specified and as directed. Make: Legrand /Havells/ABB
S&F in repair, 4 pole MCCB 100 amp, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S, complete all as specified and as directed. Make :Havells/Legrand/ABB
S&F in repair, 4 pole MCCB 125 amp, 415 volts 16 KA rupturing capacity including proper thimbles, fixing on DB'S, complete all as specified and as directed. Make :Havells/Legrand/ABB
S&F in repair, electronic driver as per sample for LED fitting up to 15watt, complete all as specified and as directed. Make Crompton/Havells/CG/Philips/Osram.
S&F in repair, electronic driver as per sample for LED fitting up to 45 watt, complete all as specified and as directed. Make Crompton/Havells/CG/Philips/Osram.
Taking down bldg security light upto 45 watt and refixing the same after repiar, complete all as directed by Engr -in-charge, (Note: Electronic drivers are paid sepearately under respective item of BOQ)
S&F in repair, remote bell ding dong type, complete all as specified and as directed by Engr-in-charge.
S&F in repair, 2-Watt LED Wall Light (bed light) for reading, complete all as specified and as directed by Engr-in-charge. Make: Philips 30975 or equivalent in Havells/ crompton etc.
S&F in repair, LED Surface Downlighter (False Ceiling Light) 12 watt of size 173.5 x 173.5 mm, complete all as specified and as directed by Engr-in Charge. Make: crompton, havells, Philips
S&F in repair, Spot light 6 Watts Black/ white Body LED Spot Light, Focus Light (Warm White), complete all as specified and as directed by Engr-in- charge
S&F in repair, PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/burnt circuit, complete all as specified and as directed.
S&F in repair, PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 2.5 sqmm as in replacement of any defective/burnt circuit, complete all as specified and as directed.
S&F in repair, PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 4.0 sqmm as in replacement of any defective/burnt circuit, complete all as specified and as directed.
S&F in repair, PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 6.0 sqmm as in replacement of any defective/burnt circuit, complete all as specified and as directed.
S&F in Street light bracket made out of medium grade GI Pipe 32 mm dia, 1.50 m long, bent to shape including GI Clamps nut, bolts washers, reducer of required size for suitable any type fittings etc complete including necessary painting, complete all as specified and as directed by Engr-in Charge.
Taking down carefully copper/aluminium point wiring for light, fan, bell socket power slocket etc complete with boards, outlet boxes fittings and fixtures such as switchs, sockets, lamp holders bracket, ceiling rose etc, complete all as directed.
M&L for Point wiring complete with 1.5 sq mm single core multi stranded copper conductor PVC (FRLS) insulated unsheathed cable confirming to IS-694,1100 Volts grade passing in PVC cassing-N-capping 25/32 mm dia fixed on surface of wall/ roof/ ceiling with existing/new sunken pressed steel terminal boxes including 3.00 mm thick plastic laminated sheet top cover and 1.50 sq mm PVC insulated unsheathed stranded copper conductor(FRLS) cable for common earth and connecting to earth dolly material and labour for, complete all as specified and as directed. Make: Havells,polycab:- (a) One light point controlled by one, one way switch
(b) One fan point controlled by one way switch, complete all as specified and as directed.
(c) One socket outlet 3 pin 5/6 Amps on same board, complete all as specified and as directed.
(d) One socket outlet 3 pin 5/6 Amp on independent board, complete all as specified and as directed.
(e) One bell point controlled by one bell push, complete all as specified and as directed.
(f) One light point controlled by two, two-way switches, complete all as specified and as directed.
All as per item No 51 above but with using 2.5 Sq mm single core multistanded copper conductor cable including 2.5 sq mm PVC insulated unsheathed stranded copper conductor for common earth wire for 6 pin 16 Amp socket outlet on independent board, complete all as specified and as directed.
S&F in repair, one bakelite sheet not less then 3mm thick after removing all connection including cutting/chassing to accommedate existing fitment and making connection including cadmium plated screws with cup washer of following size, complete all as specified and as directed:- (a) 275 x 225 MM
(b) 225 x 200mm, complete all as specified and as directed.
(c) 175 x 125 mm, complete all as specified and as directed.
(d) 100 x 100 mm, complete all as specified and as directed.
Supply only GLS Coloured Lamp Red,Green,Milky,0-60 Watt, complete all as specified and as directed. Make : Philps/CG/Havell/OSRAM/WIPRO
Note for all above items:- (i)All items in BOQ are for"Materials and labour /Supply and fix" and to be executed in "Repairs" unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are required to quote their rates accordingly. (ii) The contract amount shall be arrived at after duducting amount of Schedule of "Credit" from the Total quoted amount.
M/s Shiv Builder and Suppliers
mahalaxmi enterprises
Nikhat nirman
CHAHAR ENGINEERS AND COMPANY
SNEH CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .