| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.6 CrAccepted-AOC | ₹4.6 Cr | L1 | Accepted-AOC ok |
| 2 | L2₹4.9 Cr+₹25.5 L (5.49%)Rejected-AOC 282 NASIRABHAD GANDHI CHOWK AJMER RAJASTHAN 305601 | AJMER | RAJASTHAN | 305601 | ₹4.9 Cr+₹25.5 L (5.49%) | L2 | Rejected-AOC ok |
Tender Value
₹5.0 Cr
EMD Value
₹10.0 L
Closing Date
9 Feb 2026, 5:00 pmClosed
Er.ARUN SHARMA
Executive Engineer Electrical Division PWD Ldh
Construction of New Judicial Court Complex at Khanna Distt Ludhiana (Electrical Services)
2026_CEPW_158898_1
Bid No.54 dt 29.01.2026
Open Tender
Electrical Works
Percentage
540 days
Ludhiana
Please refer Tender documents.
22 documents required · 22 mandatory
₹30,000
Yes
₹10.0 L
Yes
27 Mar 2026
30 Jan 2026
10 Feb 2026
30 Jan 2026
9 Feb 2026
30 Jan 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Cost of 4 no's Passenger Lift's
FOR JUGDES IN MAIN JCC BUILDING:-
Type and Capacity : Approximately 884 Kg( Wide) , 13 Passengers Lift without Machine Room
Speed: 1.0 Meter per second
Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.
Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way
Travel: Approximately 9 Meter (Ground to Second Floor)
Serving: 3 Floors 3 Stops 3 Openings 3 Levels (All on the same side)
Hoist way : 1875mm (Deep) x 2550mm (Wide) Clear dimensions
Headroom Height (HR): 5000mm beyond finished floor level of last landing
Pit Depth : 1600mm below the finish floor level of first landing
Car Size Area: Minimum 2.06 square meter & Maximum 2.20 square meter
Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof
Car Entrance: Center Opening Automatic Doors with vision panel of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800/900mm (wide) x 2000mm (high)
fire retardant door upto 2 hours. | - | - | - | - |
| 2 | Hoist way Entrance: Center opening Automatic Door's with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 800/900mm (wide) x 2000mm (high)
Door operation : Automatic DC Door operation with adjustable door opening and closing timings
Control: Simplex full selective collective control with and without attentdent
Operation: Automatic
Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current
Flooring: Floor Skid - Resistant as per standard
Fan: Blower Fan in Car for ventilation with Auto cut off
Lighting: LED for Car Lighting
Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings
Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)
Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level
Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level | - | - | - | - |
| 3 | Other Features :
1. Battery operated emergency light with rechargeable battery
2. Battery operated emergency alarm with rechargeable battery
3. Adjustable Guide shoes
4. Micro movement LED based buttons
5. Door Open and Close buttons
6. Emergency Intercom provided inside the elevator
7. Emergency Intercom usable without the voice communication
8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication
9. Steel items, door frames sill angle's, fascia plates, spring buffers
10. Automatic phase reversal device and Phase Failure protection
11. Call registration
12. Audio & Video System installted in the lift indicating arrival at a floor
13. Manual break lever
14. Additional car gate lock | - | - | - | - |
| 4 | 15. Automatic break testing infrared safety curten
16. Braille Buttons (Inside and outside) with Braille instructions for the communication system
17. Kick plate/Skirting
18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close.
19. Car Operating Panel
20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive
22. Fire Man switch at main lobby
23. Car false ceiling in stainless steel
24. Pit ladder
25. Anti Nuisance car call protection
26. Door Nudging
27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.
28.The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impaiments.
29. The Floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling
30. The Provision of a mirror on the wall of the lift car opposite the lift door is a postive aid to navigation for wheelchair users, Its allows the wheelcahir user to see if anyone is behind them and also to see the Floor indicatior panel. The mirror should not extend below 900mm from the lift door to avoid confusing people with impaired sight.
31.The emergency communication system should be coupled with and induction loop system installed all around the lift. Telephone units. where provided, should have an inbulit inductive coupler to aiist person using hearing aids. passenger lift to be provided, which allows easy maneuverability of wheelchair user. | 1 | Each | 22,47,675 | ₹22,47,675 |
| 5 | FOR PASSENGER IN MAIN JCC BUILDING :-
Type and Capacity : Approximately 884 Kg( Wide) , 13 Passengers Lift without Machine Room
Speed: 1.0 Meter per second
Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.
Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way
Travel: Approximately 12 Meter (basement+Ground to Second Floor)
Serving: 4 Floors 4 Stops 4 Openings 4 Levels (All on the same side)
Hoist way : 1875mm (Deep) x 2550mm (Wide) Clear dimensions
Headroom Height (HR): 5000mm beyond finished floor level of last landing
Pit Depth : 1600mm below the finish floor level of first landing
Car Size Area: Minimum 2.06 square meter & Maximum 2.20 square meter
Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof
Car Entrance: Center Opening Automatic Doors with vision panel of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800/900mm (wide) x 2000mm (high)
fire retardant door upto 2 hours | - | - | - | - |
| 6 | Hoist way Entrance: Center opening Automatic Door's with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 800/900mm (wide) x 2000mm (high)
Door operation : Automatic DC Door operation with adjustable door opening and closing timings
Control: Simplex full selective collective control with and without attentdent
Operation: Automatic
Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current
Flooring: Floor Skid - Resistant as per standard
Fan: Blower Fan in Car for ventilation with Auto cut off
Lighting: LED for Car Lighting
Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings
Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)
Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level
Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level | - | - | - | - |
| 7 | Other Features :
1. Battery operated emergency light with rechargeable battery
2. Battery operated emergency alarm with rechargeable battery
3. Adjustable Guide shoes
4. Micro movement LED based buttons
5. Door Open and Close buttons
6. Emergency Intercom provided inside the elevator
7. Emergency Intercom usable without the voice communication
8. Load weighing device with overload bypass feature and Overload function with Audio Visual Indication
9. Steel items, door frames sill angle's, fascia plates, spring buffers
10. Automatic phase reversal device and Phase Failure protection
11. Call registration
12. Audio & Video System installted in the lift indicating arrival at a floor
13. Manual break lever
14. Additional car gate lock | - | - | - | - |
| 8 | 15. Automatic break testing infrared safety curten
16. Braille Buttons (Inside and outside) with Braille instructions for the communication system
17. Kick plate/Skirting
18. Lift anoucement system to announce floor level's in english language only and indication of door for entrance / exit is either Open or Close.
19. Car Operating Panel
20. Car plateform constructed out of cold rolled grain oreinted formed sheets of steel 21. Phase two device fire man drive
22. Fire Man switch at main lobby
23. Car false ceiling in stainless steel
24. Pit ladder 25. Anti Nuisance car call protection 26. Door Nudging
27. Automated Resuce Device to bring the elevator to the nearest landing in case of power failure.
28.The use of visually and acoustically reflective wall surfaces should be minimized within the lift car as visual reflections can cause discomfort and affect the visual acuity of people with impaiments.
29. The Floor of the lift car should be slip resistant and have similar frictional qualitites to the floor of the lift landing to decrease the risk of stumbling
30. The Provision of a mirror on the wall of the lift car opposite the lift door is a postive aid to navigation for wheelchair users, Its allows the wheelcahir user to see if anyone is behind them and also to see the Floor indicatior panel. The mirror should not extend below 900mm from the lift door to avoid confusing people with impaired sight.
31.The emergency communication system should be coupled with and induction loop system installed all around the lift. Telephone units. where provided, should have an inbulit inductive coupler to aiist person using hearing aids. 13 passenger lift to be provided, which allows easy maneuverability of wheelchair user. | 2 | Each | 22,53,575 | ₹45,07,150 |
| 9 | FOR MULTILEVEL PARKING:-
Type and Capacity : Approximately 884 Kg( Deep) , 13 Passengers Lift without Machine Room
Speed: 1.0 Meter per second
Type of drive: AC Variable Voltage Variable Frequency with 16-Bit Microprocessor.
Motor: Permanent Magnet Gearless Machine to be hoisted on the top of guide rail within the elevator hoist way
Travel: Approximately 9 Meter (Ground to Second Floor)
Serving: 3 Floors 3 Stops 3 Openings 3 Levels (All on the same side)
Hoist way : 2667mm (Wide) x 2184mm (Deep) Clear dimensions
Headroom Height (HR): 5000mm beyond finished floor level of last landing
Pit Depth : 1600mm below the finish floor level of first landing
Car Size Area: Minimum 2.06 square meter & Maximum 2.20 square meter
Car Enclosure : Constructed out of stainless steel finish panel in Scratch Resistance/ Vandal proof
Car Entrance: Center Opening Automatic Doors with vision panel of Stainless steel finish panel in Scratch Resistance/ Vandal proof with a clear opening of 800/900mm (wide) x 2000mm (high)
fire retardant door upto 2 hours | - | - | - | - |
| 10 | Hoist way Entrance: Center opening Automatic Door's with vision panel (Upto 40% area should be visible by glass) of Stainless steel finish panel in Scratch Resistance/ Vandal proof with provision of emergency key opening at landings with a clear opening of 800/900mm (wide) x 2000mm (high)
Door operation : Automatic DC Door operation with adjustable door opening and closing timings
Control: Simplex full selective collective control with and without attentdent
Operation: Automatic
Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current
Flooring: Floor Skid - Resistant as per standard
Fan: Blower Fan in Car for ventilation with Auto cut off
Lighting: LED for Car Lighting
Indicators: LED Dot matrix / Digital 3 segement direction and position indicators in the car and at all landings
Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear)
Call Button Height: Call button (Outside the lift) placed at a height between 800mm-1meter from the floor level
Control Panel Height: Control panel placed at a height between 800mm-1meter from the floor level | - | - | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 21.38 MB
Tendernotice_2.pdf
PDF • 34.29 MB
BOQ_322223.xls
BOQ • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .