Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC KHAYERPUR OLD AGARTALA | OLD AGARTALA | TRIPURA | ₹18.9 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹19.9 L+₹1.0 L (5.50%)Rejected-AOC R D UDAIPUR DIVISION GOMATI DISTRICT TRIPURA | ₹19.9 L+₹1.0 L (5.50%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹20.6 L+₹1.7 L (8.76%)Rejected-AOC MECHURIYA SALEMA KAMALPUR DHALAI TRIPURA | DHALAI | TRIPURA | 799278 | ₹20.6 L+₹1.7 L (8.76%) | L3 | Rejected-AOC L3 bidder |
| 4 | L4₹21.5 L+₹2.6 L (14.0%)Rejected-AOC | ₹21.5 L+₹2.6 L (14.0%) | L4 | Rejected-AOC L4 bidder |
Tender Value
₹24.2 L
EMD Value
₹48,455
Closing Date
6 Apr 2026, 3:00 pmClosed
Executive Engineer,PWD(R and B),Kamalpur Division
O/o. EE, PWD(R and B), Kamalpur Division
SH- RCC drain and other allied works etc
2026_CEPWD_71794_1
32/EE/PWD(RnB)/KMP/DIV/2025-26
Open Tender
Civil Works - Roads
Percentage
Salema
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,000
₹48,455
Yes
29 Apr 2026
26 Mar 2026
6 Apr 2026
27 Mar 2026
6 Apr 2026
27 Mar 2026
27 Mar 2026 - 4 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Excavation for Structures. B. With dewatering. Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, dewatering, construction of shoring, shuttering & bracing, removal of stumps & other deleterious material and disposal upto a lead of 50 m, dressing of sides & bottom and backfilling in trenches with excavated suitable material. I Ordinary Soil (i) Upto 3 m depth. | |||||
| 2Filling in foundation trenches as per drawing & MoRD technical specification Clause 305.3.9, 1200. I. Sand filling. | |||||
| 3Providing concrete for plain concrete (using jhama brick aggregate) in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc. but excluding reinforcement) I. P.C.C grade M10 (using jhama brick aggregate). i) Nominal mix 1:3:6 | |||||
| 4Providing concrete for plain/reinforced concrete in open foundations complete including formwork as per drawings & MoRD technical specifications Clauses 802, 803, 900, 1202 and 1203. (including centering, shuttering, staging etc.but excluding reinforcement). IV R.C.C grade M 20 | |||||
| 5Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar reinforcement in foundation complete as per drawings & MoRD technical specifications Clauses 1000 & 1202. | |||||
| 6Plain/reinforced cement concrete in substructure complete including formwork as per drawings & MoRD technical specification Clauses 802, 804, 805, 806, 807, 900, 1202 & 1204. (including centering, shuttering, staging etc. but excluding reinforcement) VI. R.C.C grade M-25.i) Upto 5 m height. | |||||
| 7Supplying, fitting & placing Thermo-Mechanically treated bar/ Cold twisted deformed steel bar in substructure complete as per drawings & MoRD technical specification Clauses 1002, 1005, 1010 and 1202. | |||||
| 8Providing weep holes in brick masonry/ stone masonry, plain/ reinforced concrete abutment, wing wall, return wall with 100 mm dia AC pipe or uPVC pipe (110 mm OD of 6.0 kg/cm2 pressure) extending through the full width of the structures with slope of 1(V):20(H) towards drawing face complete as per drawing and MoRD technical specification clauses 614, 709, 1204.3.7. | |||||
| 9Providing & laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil & bigger size towards the wall & providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and MoRD technical specification clause 1204.3.8. | |||||
| 10Providing & laying reinforced cement concrete in superstructure as per drawings & MoRD technical specifications Clauses 800, 900, 1205.4 & 1205.5 (including centering, shuttering, staging etc. but excluding reinforcement). II) R.C.C grade M-25. 1) For height upto 5 m. | |||||
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_73065.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.65 MB
tenderdocument.pdf
Tender Documents • 2.16 MB
BOQ_73065.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .