| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.9 L+₹3.0 L (29.9%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹13.7 L+₹3.8 L (38.2%)Rejected-Finance AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹13.9 L+₹4.0 L (40.3%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹16.3 L+₹6.4 L (64.2%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
28 Apr 2023, 6:00 pmClosed
GE KARGIL
MES OFFICE KARGIL LADAKH
REPAIR AND MAINTENANCE OF TRANSFORMER AND ALLIED WORKS OF VARIOUS UNITS AT KARGIL KAKSAR HENISKUT BUDHKHARBU APATI CHHANIGUND AND HARDAS UNDER GE KARGIL
2023_MES_587706_1
GE/K-58/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KARGIL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KARGIL
₹36,000
Yes
7 Aug 2023
31 Mar 2023
1 May 2023
31 Mar 2023
28 Apr 2023
14 Apr 2023
Amount
Dismantling transformer of capacity 100 KVA to 500 KVA out door /Indoor type from platform ,transport to workshop for repair and re-installing after repair at site including connecting up as directed by the Engr-in-Charge (cost of repair charges paid against respetive items below)
Supply and replacement of HT coils made out of super enamelled copper winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 % pure and ISI Marked
Supply and replacement of LT coils made out of super enamelled copper winding wires of same guage and same no of turns as required as per transformer of any capacity including replacement of paper insulation ,insulating meterial and proper end connection .The rewinding oil shall be heat treated in an electric oven complete as directed. Copper wire shall be 99.9 %pure and ISI Marked
Painting of transformer of any capacity indoor/outdor type after cleaning the outer surface of the transformer by rubbing with emery paper ,remove oil particles, dust etc and applying one coat of synthetic enamel paint of smoke gray colour as directed
Supply and replacement of HT (11KV) Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 63 to 500 KVA.
Supply and replacement of LT (11KV) Bushing complete with brass spindle with nut bolt,washer ,ceramic bushing and rubber washer for Transformer capacity of 63 to 500 KVA
Supply and replacement of High quality core gasket for transformer top lid cover for Transformer capacity of 63 to 500 KVA
Replacement of Top up transformer oil of die electric strength not less than 40 KV at 4 mm gap conforming to relevent IS complete all as specified and directed by the Engr-in-Charge
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip size 32X6mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
S&F of Lightening arrestor surge station type 12 kv (rms) , having breaking capacity 10 KA, Polymeric housing , suitable for HT overhead network including necessary connections with HT overhead lines complete, Note- Connections of arrestor with HT line shall be done with XLPE insulated single core cable jumper of size 95 sqmm which shall be part of item at no extra cost
S&F of Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20 cm size complete all as specified
Disconnecting LT connection from the Transformer and shifting the transformer not more than 160 KVA to existing two pole structure within 10 meter distance including shifting of HT line to new 2 pole structure and connecting up complete (The rate included the rates fixing arrangements, any type of clamps, connection meterial as anything required at site) (Any type of damage of transformer while shifting will be the responsibility of contractor)
S&F of Cable jointing kit for 11000 volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed by Engr in charge.
same as item S.No-25 but for cable 120 sq mm to 185 sqmm
S&F HT Ariel Bunched (AB) cable 95 sq mm, 1 core complete all as specified and directed by Engr in charge.
S&F of XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sq. mm, 3 Core complete all as specified and directed by Engr in charge.
opening of unservicable voltage stablizer upto 5 kva and taken to workshop for repairs, replacement of all unservicable parts with new one including copper winding,bringing back stablizer after repairs and connecting, testing to the satisfication of Engineer-in-Charge complete. (NOTE- payment of copper winding will be paid separately in the respective item.all other parts shall be included in this item.)
Note :Deduction for amount of Rs 102070.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
M/S HAJI HASSAN ENGINEERING WORKS
EVERGREEN GROUP OF INDUSTRIES
darshan kumar gandhi
M/S TRADE LINK
SUMEET TRADING CORPORATION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .