| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 CrAccepted-AOC | ₹18.8 Cr | L1 | Accepted-AOC Amount derived after deducting Schedule of credit and contractor discount |
| 2 | L2₹19.3 Cr+₹53.2 L (2.83%)Rejected-Finance PLOT NO 341 LUV KUSH MARG KANAK VRINDAVAN PANCHYAWALA SIRSI ROAD JAIPUR 302034 RAJASTHAN | JAIPUR | JAIPUR | RAJASTHAN | 302034 | ₹19.3 Cr+₹53.2 L (2.83%) | L2 | Rejected-Finance Other than lowest bidder. Amount after deducting schedule of credit. |
| 3 | L3₹19.7 Cr+₹94.3 L (5.02%)Rejected-Finance | ₹19.7 Cr+₹94.3 L (5.02%) | L3 | Rejected-Finance Other than lowest bidder. Amount after deducting schedule of credit. |
| 4 | L4₹19.9 Cr+₹1.1 Cr (5.89%)Rejected-Finance 15 16 GANGA COLONY KHATIPURA ROAD JAIPUR RAJ 302012 | JAIPUR | JAIPUR | RAJASTHAN | 302012 | ₹19.9 Cr+₹1.1 Cr (5.89%) | L4 | Rejected-Finance Other than lowest bidder. Amount after deducting schedule of credit. |
| 5 | L5₹21.1 Cr+₹2.3 Cr (12.4%)Rejected-Finance | ₹21.1 Cr+₹2.3 Cr (12.4%) | L5 | Rejected-Finance Other than lowest bidder. Amount after deducting schedule of credit. |
Tender Value
₹17.5 Cr
EMD Value
₹12 L
Closing Date
5 Jun 2020, 6:00 pmClosed
Chief Engineer Navy Visakhapatnam
Chief Engineer Navy Visakhapatnam Station Road Visakhapatnam 530004
PROVISION OF DEFICIENT CIVILIAN MARRIED ACCOMMODATION AT VISAKHAPATNAM
2018_MES_189683_2
CE NAVY/VIZ/TOKEN/03 OF 2018-19
Open Tender
Civil Works
Lump-sum
730 days
Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹3,000
Garrison Engineer(P) (N) Visakhapatnam
₹12 L
Yes
Chief Engineer Navy Visakhapatnam
1 Jul 2020
30 Jan 2020
6 Jun 2020
30 Jan 2020
5 Jun 2020
5 Mar 2020
4 Feb 2020
Amount
PHASE I Schedule "A" Part – I to Schedule "A" Part – XIV]: NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lumpsum price worked out by the contractor for "BUILDINGS & STRUCTURES ", as listed in Schedule "A" Part – I on Serial Page No. 33 .
Lumpsum price worked out by the contractor for "EARTHWORK AND EXCAVATION ", as listed in Schedule "A" Part – II on Serial Page No. 34.
Lumpsum price worked out by the contractor for " PILE FOUNDATION ", as listed in Schedule "A" Part – III on Serial Page No. 35.
Lumpsum price worked out by the contractor for "INTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – IV on Serial Page No. 37.
Lumpsum price worked out by the contractor for "INTERNAL ELECTRIFICATION AND WATER COOLER ", as listed in Schedule "A" Part – V on Serial Page No. 39
Lumpsum price worked out by the contractor for "EXTERNAL WATER SUPPLY ", as listed in Schedule "A" Part – VI on Serial Page No. 40 .
Lumpsum price worked out by the contractor for "EXTERNAL ELECTRIFICATION ", as listed in Schedule "A" Part – VII on Serial Page No. 42.
Lumpsum price worked out by the contractor for "AREA DRAINAGE ", as listed in Schedule "A" Part – VIII on Serial Page No. 43.
Lumpsum price worked out by the contractor for "SEWAGE DISPOSAL ", as listed in Schedule "A" Part – IX on Serial Page No. 45.
Lumpsum price worked out by the contractor for "ROAD / PATH / HARDSTANDING ", as listed in Schedule "A" Part – X on Serial Page No. 47.
Lumpsum price worked out by the contractor for "DEMOLITION & DISMANTLING ", as listed in Schedule "A" Part – XI on Serial Page No. 49.
Lumpsum price worked out by the contractor for "LIGHTING PROTECTION ", as listed in Schedule "A" Part – XII on Serial Page No. 50.
Lumpsum price worked out by the contractor for "FIRE FIGHTING SYSTEM ", as listed in Schedule "A" Part – XIII on Serial Page No. 53.
Schedule "A" Part - XIV: [PILE FOUNDATION, EXTERNAL WATER SUPPLY, INTERNAL ELECTRIFICATION, AVIATION LIGHT, LIFTS, DG SET, FIRE FIGHTING, EXTERNAL ELECTRIFICATION, DEMOLITION & DISMANTLING, LIGHTING PROTECTION AND ARBORICULTURE] [Serial Item No. 14 to 73 of BOQ] [To be quoted by the Tenderer in BOQ]
Loop in Loop out thermosplastic cable junction boxes of size 250 x 250 x 100 mm made out of 1.6 mm thick MS Sheet comprising with MCB SP 6 Amp and 4 Porcelain terminals as bus terminals for cable with necessary fixing arrangemets with cable glands, etc preparing the surface and appling two coats of synetic enamel paint over a coat of primer etc all as directed. (for Security Lights) Make: Hensel/Sintex
Supply, fabricate, install, test and commissioning LT Panel board confirming to CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material as per IS: 8623 Aluminium bus bar of 500 Amps rating with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 500 A capacity complete with powder coating, necessary internal electric wiring / connection as required and provision of the following : a) FOR INCOMING (i) LT 440 volts 3 phase, 4 wire 50 cycles, 36kA, Adjustable type MCCB of 250 Amp rated complete with overload protection, no volt thermal based release - 01 Nos. b) (FOR OUT GOING) (ii) LT 440 volts 3 phase, 4 wire 50 cycles, 36 kA, Adjustable type MCCB of 63 Amp rated complete with overload protection, no volt thermal based release.- 10 Nos. (iii) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases - 03 set of three, (iv) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs Make: Schinder / L&T - 1 set of three
Supply, fabricate, install, test and commissioning LT Panel board confirming to CPRI approved manufacturer made out of CRCA sheet 3.15 mm thick Outdoor Pedestal type totally enclosed with front and rear opening, hinged doors with projected on raised PCC platform with PCC 1:2:4 type B1 (20mm graded aggregate) of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 Aluminium bus bar with heat proof colour code, insulators suitable for three phase and four wire LT AC, 50 Hz 415 V 800 A capacity complete with powder coating, necessary internal electric wiring / connection as required and provision of the following (LT panel near bldg) : a) FOR INCOMING (i) LT 440 volts 3 phase, 4 wire 50 cycles, 50 kA, Adjustable type MCCB of 400 Amp rated complete with overload protection, no volts thermal based release -01 No., b) (FOR OUT GOING) (ii) LT 440 volts 3 phase, 4 wire 50 cycles, 36kA, Adjustable type MCCB of 250 Amp rated complete with overload protection, no volts thermal based release.- 03 Nos. ( 02 for LT panel and one for spare), (iii) LT 440 volts 3 phase, 4 wire 50 cycles, 36kA, Adjustable type MCCB of 125 Amp rated complete with overload protection, no volts thermal based release. - 01 Nos (01 for AMF DG Panel bldg load, 01 for Street Light and 01 for spare) (iv) LT 440 volts 3 phase, 4 wire 50 cycles, 25kA, Adjustable type MCB TPN of 32 Amp rated complete with overload protection, no volts thermal based release. - 02 Nos ( for Street Light) (v) LED Indicating Lamps for ech phase with colour coed Red Yellow Blue for R, Y and B Phases - 01 set of three, (vi) Multifunctional Intelligent Panel Meter digital type for measuring Volts, Current, Hz, pf, power, energy, THD along with connected CTs Make: Schinder / L&T - 01 set of three
Supply and fix 63 Amps TP MCB metallic P&S complete all as specified and directed. (For lift machine room)
Supply & Fix Integral LED street light Luminaire 72 Watts, comprising of epoxy powder coated, Pressure die cast aluminium housing enclosed with glass cover in frame, with suitable size of bracket, nut and bolts, PVC insulated three core flexible cable of suitable size and length duly connected to light fitting complete including installation and testing Make:- Bajaj cat part No. BRTFG 72W LED or eqvellent of Model in Philips/ CG / Havells
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified.
Supply and fix LT Sheet Metal Enclosure made out of CRCA sheet 3.15 mm thick Outdoor type totally enclosed with front opening, hinged door with projected on raised platform of suitable size weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of Switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per IS: 8623 with MCCB 400 Amps 4 Ploe Adjustable type for three phase and four wire LT AC, 50 Hz 415 V, Multifunctional Digital meter for Voltage, Ampers, KWH, etc, LED indicating Lamps with powder coating, as required complete all as specified and directed
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Supply & planting carpet grass including preparation of ground up to 30cm deep and filling soft soil,cow dung and watering etc complete (loose soil and cow dung will measured separately).
Supply only approved loose soil best quality for plantation
Supply only approved vermi compost of the best quality
Supply and planting Jamun Plant including prepration of ground up to 30cm deep and filling soft soil, cow dung and watering etc. all as specified and directed
Supply and planting Gulmohar/ Ashoka, Jamun etc.Plant including prepration of ground up to 30cm deep and filling soft soil, cow dung and watering etc. all as specified and directed
Cutting existing steel tubing of 150/200 dia for alterations or additions necessarily done in position without taking down, dewatering for inserting flanged sockets, 'Tee' with reducer to 80 mm, etc for tapping all as specified and directed.
Demolition of IWC including concrete complete all as specified and directed
Taking out existing Low Level /High Level flushing cystern complete all as specified and directed
Taking out Bib Tap / Stop Cock of any make , dia complete all as specified and directed
Aviation obstruction light LED type filament-less bulb with 10 Watt bulb complete including standard fixing arrangements complete all as specified and as directed (Make :-Havells/ Bajaj / CG /Philips / Wipro /Surya).
Time switches 450 V Three Phase of 20 Amp rating with contactor fitted inside steel enclosure including standard fixing arrangements complete all as specified and as directed (Make :- Legrand, Model No. 412813 or equivallent in Havells/ L&T / MDS /Simens)
Taking down sub main wiring with aluminium/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ batten / conduit including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified & directed.
Taking down MCB DB any type or make complete all as specified & directed.
Point Wiring complete with 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, confirming to IS - 694, 1980 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. and Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for One Light / Fan Point / Bell Point controlled by One Switch complete all as specified.
All as per Serial Item No. 36 above but One 3 Pin Switch Socket Outlet 5 Amps on Independent Board complete all as specified.
All as per Serial Item No. 36 above but one 3/5 Pin Switch Socket Outlet 15 Amps on independent board, with 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable confirming to IS - 694, 1980 and including 1100 Volts, FRLS grade, 4.0 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable as Earth Continuity Conductor.
All as per Serial Item No. 36 above but One Light point controlled by two two way switches complete all as specified.
Modular Switch socket Combination 6A, 2/3 pin, 3 module complete all as specified and as directed.
S&F Energy efficient LED ceiling light fittings 1 x 10 W integral round shape 230 volts, surface mounted type with with acrylic cover as diffuser and all accessories, mounting bracket, pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed. (Make - Surya Cat No. SLEDDLS10WXX STELLAR or equivalent in Havells/ Bajaj/CG/Philips)/ Wipro
S&F Energy efficient LED T/L fitting 1 x 19/ 20 W wall / ceiling mounted type with metalic channel and white reflactor complete with acrylic cover as diffuser and all accessories, mounting bracket, pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed. (Make - Surya Cat No. SUB118T8LED or equivalent in Havells/ Bajaj/CG/Philips)/ Wipro
S&F LED Security light fitting with drive of 20W, New generation Energy saving & enviornmental frindly long life versatile presssure die cast aluminium luminiare with mid power LEDs as source and HF electronic driver pre wired with 1.5 Sqmm copper conductor cable upto connector including 2.0 Mtr Long GI Tubing Med grade 32mm dia bend to shape fixing on wall with suitable MS brackets complete all as specified and as directed. Make: Havells / Philips/Bajaj/GE/Wipro/Surya
S&F Energy efficient LED mirror light fitting 1 x 10 W wall mounted type complete with necessary diffuser and all accessories, mounting bracket etc. with pre wired and including connecting up with twin core twisted flexible copper conductor cable of suitable size and fixing arrangement complete all as specified and directed Make - Havells / Bajaj / CG / Philips/Wipro/Surya
S&F ceiling fans AC single phase 230 V of size 1200mm sweep with complete set with fixtures. BEE 5 star rating, metallic body including provision of three core flexiable copper wireof size 23/0.0076from ceiling rose to celing fan complete all as specified and directed. Make: Havells/Bajaj/CG/Orient
S&F Exhaust fan 200mm sweep or nearest size, Resign body, 1250 RPM, complete with louvers suitable for operation on 230V AC, 50HZ AC Supply including provision of three core flexiable copper wireof size 23/0.0076from ceiling rose to exhaust fan fixed on wall making opening, fixing and making good the distrubered surfaces etc complete all as specified and as directed. Make:-Havells/Bajaj/CG/Orient.
MCB single pole 6 to 30 amps, 240 volts, 10 KA, 'B' series with all incoming / outgoing connections with proper size of aluminium lugs complete all as specified as directed Note:(i) Cost of copper lugs shall be included in the unit rate.
MCB single pole & neutral 32 amps, 240 volts, 10 KA, 'C' series with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed
S&F glossy white Co- Axial TV socket outlet complete all as specified and directed
Sub main wiring with 03 runs of 6.0 sqmm single core, FRLS, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable, 1100 Volts, ISI Marked, drawing through and including PVC rigid conduit not less than 40mm dia. complete with necessary fittings such as junction boxes couplings, unions bends reducers, inspection elbows, plugs, sealing condulets eyc complete all as specified and directed . ( Note: 3 runs of 6 Sqmm cable one run of conduit will be measured as one unit i.e RM).
Supply and fix Cable PVC insulated armoud PVC sheathed LT 1100 V grade with copper conductor of size 3 core 2.5 sqmm multi stranded conductor laid in ground/ fixed to wall / floor / roof etc with suitable calmps spacers bolts nuts etc complete all as spcidied and as directed
Supply and fix 2 core 2.5 sqmm FRLS armoured copper cable as per IS:1554 to wall/ roof/ false ceiling/ floors with necessary clamps/ saddles complete all as specified and directeed.
Supply and fix GI Cable tray with cover for fixing XLPE cable from duty room to terrace for siren and at various palces to accommodate the cables for MCPs, Panel etc of size not less than 75x38 mmx 2mm thick with necessary bends, angles, supports for fixing, etc complete all as specified and directeed. (Make :-Legrand or equivallent in Havells/ L&T / MDS /Simens)
Supply and fix MS cabinet (approx 750mm x 600mm x 450mm) to encl fire brigade inlet connections fabricated from 16 gauge sheet with full front glass door and locking arrangement painted and mounted on masonry platform complete all as specified and directeed.
Supply, install and testing of (geyser) water heate storage type of 15 Ltrs capacity 5 star rated, suitable for operating supply of AC, 230 V, 50 Hz, Single Phase complete including supplying and fixing 02 nos 15 mm size brass chromium plated angular stop cock and 02 screwed down high pressure with crutch or butterfly handle for iron pipe and 02 nos heavy duty PVC connection pipe complete all as specified and directed. (Make of geyser:- Havells / CG /Recold/Jaquar)
(a) Fire man switch
(b) Automatic rescue devide (ARD) during power failure including manual operation provision with suitable capacity of battery designed for funnign the lift with full load.
c) Battery operated emergency light (LED ceiling fitting), alarm (speaker for emergency alarm sustem to be fixed) and stop button in car with rechargeable arrangement for battery.
d) Six sleek circular LED light fitting in false ceiling .
e) One Sleek circular PVC heavy duty fan in false ceiling. Make for(c) & (d) : Philips / Bajaj / Havells / Crompton Greaves.
f) Granite slab 18 to 20 mm thick any colour as directed as in flooring complete.
g) Non stop button / independent operation.
h) Over load warning indicator both audio and visual type with tripping sustem having relays etc (overload protectin / tripping system).
j) Front landing door of stainless steel of grade SS -316, mirror finish operations with a minimum time of 10 seconds and up to a maximum time of 30 seconds.
k) Car size shall be conformity with IS-3534-1976 and body to be stainless steel of 16 gauge grade SS -316, mirror finish with stainless steel hand rail 38 mm hairline finish.
l) Set of three in number limit swithces at the bottom and top most position of lift hoist ways as specified in IS.
m) Mirror of 4 mm thickness of suitable size as specified.
n) Opening with mirror of 5mm thick 200 x 600 mm size in all the doors (Car/Landing doors).
o) Specification plate with complete details .
p) Contineuos earthing for machine and equipments.
q) Steel wire rope of adequate sixze as per relevant IS and as per manufacturerer specifications.
r) Other standard fixtures and fitting like guide rails, sheaves, counter weights with guards, buffers, gear unit breakes, control panel, locks, governor, car operational panel, power, control and trailing cables complete.
s) Full length display indicator panle.
t) Main drives and control shall be of latest, high effective and llow power consumption.
u) Suitable phase reversal relay shall be provided on the controller to protect lift / equipment against phase reversal, phase failure and low voltage.
v) Stainless steel fron opend landing door with small opening for vision of size 200 mm x 800 mm with toughended galss not lkess than 8mm thick. Kame of Toughened Glass : Safgex / Saint Gobain Glass / Modiguard float glass / kesar / Asshi Indian / Atul Tuf / Hindustan pilkington glass works / Trivenin float glass.
w) Intercome be connected with nearest security post.
Makes of Passagneer Lift :- OTIS / Thyseen Krupp / MITSUBISHI / JOHNSON
All as per Item No. 56 above but for 13 Passengers (884 Kgs capacity)
Supplying, installing, commissioning & testing of Silent engine generating set with accoustic enclosure as per CPCB norms 415 volts 62.5 kVA 3 phase 0.8 power factor 50 Hz, 1500 RPM self excited self regulated brushless AC generator including accoustic enclosure suitable for ambient condition and conforming to condition under IS 4722, BS 5514/ 2613 /5000 complete all as specified and directed with the following :- (A) Alternator :- Standard design alternator rated at 62.5 kVA net output at site after considering de-rating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self excited self regulated screen protected drip proof IP 23 enclosure brushless design with winding in pole faces, insulating class 'H' and voltage regulation of +/- 1% at rated voltage from no load to full load. The alternator shall be conforming to BS 2613/5000 and shall be imposition to generate supply with frequency regulation with in +/- 1% tolerance. The alternator will be suitable for tropical climate and shall generally conform to BS - 2613/5000/ IS – 4722.The Alternator shall be:- i) Insualation class - 'H‘ ii) Temparature rise Class - 'H‘ iii) Excitation : Self Excited iv) Regulation performance: The voltage is kept constant with +/- 1%, manual voltage adjustment within +/- 5% v) Frequency regulation +/- 1%
(B) Diesel Engine: - Adequate capacity of Diesel engine as accosted by the accepting officer basing on manufacturers technical details water cooled to drive independently above alternator and after considering de-rating as per site conditions after generating and reducing power consumed by accessories directly coupled through flexible coupling multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for half an hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under :- i)Fly wheel with housing ii) Cooling system :- Moulded radiator with fan & belts iii) Cooling Water pump : - Centrifugal type belt driven iv) Exhaust System :- Exhaust System complete with exhaust piping of 150mm dia with MS pipe light grade upto & outside and 1meter away from the enclosure, covered with asbestos rope and aluminium foil of 28 SWG complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type. Exhaust manifold Silencer : Residual type Bellows iv) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch controlled by electronic governor for 1% speed /frequency regulation, Fuel filters, Fuel hoses. v) Lub oil System :(a)Lubricating oil filter (b) Lubricating oil pump vi) Air Intake System : (a) Air intake Manifold - Air cleaner dry type vii) Governor :- Electronic Governor viii) Starting System :- Electric Self starter with maintenance free battery including battery charging alternator
ix) Batteries :- Batteries of maintenance free of capacity as recommended by the manufacturer complete with copper conductor multi stranded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolyte all as specified and Starter gear ring Start and stop push button, Ignition key / Switch Handling and operation : Salient features of accessories shall be as under: Radiator with blower fan Corrosion inhibitor coolant, Paper element filters for fuel, lub oil and by pass, Electronic governor controlled direct fuel injection system Fly wheel housing and fly wheel x) Generator Monitoring Panel : - Comprising of all standard items as mentioned under this schedule or asper standard practice iginiton key switch and start / stop arrangement, indications for Engine parametes, hour run meter, RPM meter, Engine oil pressure indicator, water/coolent temparature indicator, Battary volt display. xi) Safety Controls : - Engine low lube oil pressure high water temparature and over speeding of engine xii) Coupling arrangement : - Flexible coupling, fly wheel to suit flexible coupling xiii) Accessories :- AVM Pads built in enclosure and for entire unit on platform. xiv) Base Frame : - Should be provided as OEM norms xv) Fuel Tank :- Additional Fuel Tank of capcaity to suit Daily service fuel tank made out of 3mm thick (10G) HR sheet top and bottom with caliberated level indicating arrangement, stop cock, drain plug, fuel pump of suitable capacity complete on a common base out side the accoustic enclosure. xvi) MS pipe line to and from the fuel tank to the DG Set
D) Accoustic Enclosure:- Manufactured by OEM suitable for 62.5 KVA DG Set (i) NAL approved as per CPCB (ii) It Should be as per latest rules and regulations of Ministry of Environment and Forest and Pollution control board (iii) The generating set battaries and control panel should be inside the enclosure. (iv) Fuel tank should be out side the enclosure in the sub station building. (v) Construction Details/specification are as follows: a) Outer body :- CRCA Sheet of 1.6mm thick b) Doors :- CRCA sheet of 1.6 mm thick c) Sound Insulation :- As per OEM Norms vi) The accoustic should be composite in construction and fully assembled integral unit vii) The batteries should be placed inside the enclosure beside the DG Set on a suitable insulated platform viii) The fuel tank is to be located in Sub Station Building and cost of the fuel lines is deemed to be included in the offer. ix) The DG Set should be provided with external Emergency stop push button x) The enclosure should be suitably illuminated by LED Lamp fittings. xi) The noise level should be 75 dba at 1m under free field conditions. xii) The acoustic enclosure parts shall be of powder coated after pre treatment process. The powder coating shade should be Gen set Green. The base frame should be painted with epoxy based black shade
NOTES: - (i) The capacity of Generator set shall be net after all due de-rating factors as per relevant ISI design (ii) Rate quoted shall be deemed to be inclusive of cable and terminations form Generator to the AMF Panel, with necessary holes to wall including making good to disturbed surfaces so as to match with the existing finishes all as specified and directed. (iii) The quoted rate shall be deemed to be inclusive of first fill of oil and final successful acceptance test iv) The quoted rate shall include excavation, and earth workf as insoft / loose soil and PCC, Cement Concrete foundation, filling and mass concrete type B2 (1:2:4) using 40 mm graded aggregate of size as specified by manufacturer for placing of DG Set complete all as specified and directed.
Boring for bored cast-in-situ piles 600 mm dia in any type of soil / clay / soft rock except hard rock by Hydraulic system of boring methodand and getting out and disposal of spoil to a distance not exc 10KM out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 450 mm dia in any type of soil / clay / soft rock except hard rock by Hydraulic system of boring methodand and getting out and disposal of spoil to a distance not exc 10KM out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 600 mm dia in hard rock & Factured rock by Hydraulic system of boring methodand and getting out and disposal of spoil to a distance not exc 10KM out side MD land complete all as specified and directed.
Boring for bored cast-in-situ piles 450 mm dia in hard rock & Factured rock by Hydraulic system of boring methodand and getting out and disposal of spoil to a distance not exc 10KM out side MD land complete all as specified and directed.
Chipping out pile up to cutoff level incl disposal up to distance of 50m all as specified and directed.
Carrying out initial load test on 600 mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out initial load test on 450 mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out routine load test on 600 mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out routine load test on 450 mm dia pile as per IS 2911 Part IV,complete all as specified and directed.
Carrying out Initial lateral test on 600mm dia piles all as per IS-2911 Part - IV as specified and as directed.
Carrying out Initial lateral test on 450mm dia piles all as per IS-2911 Part - IV as specified and as directed.
Carrying out Initail pullout test on 600mm dia piles all as per IS-2911 Part - IV as specified and as directed.
Carrying out Initial pullout test on 450mm dia piles all as per IS-2911 Part - IV as specified and as directed.
Carrying out low strain energy test on bored cast in situ piles 600mm dia pile including analysing the results as per IS-14893-2001 as specified and as directed.
Carrying out low strain energy test on bored cast in situ piles 450mm dia pile including analysing the results as per IS-14893-2001 as specified and as directed.
PHASE II : SCHEDULE A PART XV. (MAINTENANCE OF ARBORICULTURE)
Material and labour for maintenance including watering and fertilization of all the grass/plants/tress for a period of twelve months complete all as specified and directed.
PHASE III: SCHEDULE A PART XVI. (COMPREHENSIVE MAINTENANCE OF LIFTS FOR FIRST YEAR AFTER EXPIRY OF DEFECTS LIABILITY PERIOD)
Comprehensive maintenance of electrically operated passengers lift of capacity 8 passenger (544 Kgs capacity) lift all as mentioned vide Serial Item No. 56 of BOQ complete all specified in PS and as directed for First Year after expiry of Defects Liability Period. Note: [a] The quoted rate deemed to be included the cost of consumable and minor parts which are required for smooth maintenance of lifts. [b] Defective batteries found in comprehensive maintenance shall be replaced by the contractor without any extra cost to department. [c] Comprehensive maintenance shall be deemed to be inclusive for repairs/replacement of warn out/defective parts except "lift car including car door, landing door, motors, Gear box, controllers including VVVF drive and micro processors, main rope".
All as per item No. 75 above but for 13 Passengers (884 Kgs capacity) lift all as mentioned vide Serial Item No. 57 of BOQ
PHASE IV SCHEDULE A PART XVII. (COMPREHENSIVE MAINTENANCE OF LIFTS FOR SECOND YEAR AFTER EXPIRY OF FIRST YEAR COMPREHENSIVE MAINTENANCE)
All as per item No. 75 above but for second year after expiry of first year comprehensive maintenance, lift all as mentioned vide Serial Item No. 56 of BOQ
All as per item No. 76 above but for second year after expiry of first year comprehensive maintenance, lift all as mentioned vide Serial Item No. 57 of BOQ
PHASE V SCHEDULE A PART XVIII. (COMPREHENSIVE MAINTENANCE OF LIFTS FOR THIRD YEAR AFTER EXPIRY OF SECOND YEAR COMPREHENSIVE MAINTENANCE)
All as per item No. 75 above but for third year after expiry of second year comprehensive maintenance, lift all as mentioned vide Serial Item No. 56 of BOQ
All as per item No. 76 above but for third year after expiry of second year comprehensive maintenance, lift all as mentioned vide Serial Item No. 57 of BOQ
Komal Buildcon Pvt. Ltd.
B DURGA REDDY INFRASTRUCTURES PRIVATE LIMITED
BHARATSHAH CONSTRUCTION CO
GANGA INFRABUILD PVT LTD
KCP Engineers Private Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .