Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC 4 A RUKSHMANI PARK SOCIETY OPP SAMA WATER TANK NEW SAMA ROAD VADODARA 390 008 | VADODARA | VADODARA | GUJARAT | 390008 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹29.4 L+₹3.0 L (11.2%)Rejected-AOC ARIHANT 15 A GOKUL SOCIETY SINDHWAL MATA ROAD PRATAPNAGAR VADODARA 390 004 | VADODARA | GUJARAT | 390004 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹30.5 L+₹4.0 L (15.3%)Rejected-AOC D 47 MANORATH SOCIETY NEAR AMAR COMPLEX SAMA ROAD VADODARA 390024 | VADODARA | GUJARAT | 390024 | L3 | Rejected-AOC Being not L1 |
Tender Value
Refer Docs
EMD Value
₹53,000
Closing Date
25 Jun 2021, 3:00 pmClosed
BA Nirmal Kumar EE GE Army Baroda
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2021_MES_444928_2
8577
Open Tender
Civil Works
Item Rate
180 days
GE Army Baroda
As per tender documents
5 documents required · 5 mandatory
₹500
Yes
GE Army Baroda
₹53,000
Yes
7 Sept 2021
3 Jun 2021
26 Jun 2021
3 Jun 2021
25 Jun 2021
9 Jun 2021
4 Jun 2021 - 8 Jun 2021
Amount
Demolition of stone slabs and tiles of any description or thickness in floors & wall, laid bedded & pointed in any mortar complete.
Demolition of cement concrete (unreinforced) in flooring and paving n.exc. 15cm thick (below or above ground level) including tiles of any description / similar description and removing rubbish off the premises complete.
Demolition of cement concrete (unreinforced) in flooring and paving exc. 15cm thick above ground floor including tiles of any description / similar description for sunken treatment of WC/Bath and removing rubbish off the premises complete.
Demolition of reinforced cement concrete as in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas, chullah hood and similar suspended work complete.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc n exc 10 Sqm on plan and n exc 1.5m in depth and getting out in soft / loose soil complete.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete.
Spreading and leveling of soft/loose soil in floor in layers n exc. 25 cm thick including well ramming watering as required complete..
Removing excavated soil n exc 50 m and deposited where directed at a level n. exc 1.5 m above the starting point complete.
M&L Hardcore of broken stone of gauge n exc. 63 mm, deposited, spread and leveled in layers n exc. 15 cm thick, watered and rammed to a true sur-face complete.
M&L for sunken treatment portion of WC / Bath filled with lean Plain Cement Concrete 1:5:10 using 40mm graded aggregate and finish the surfaces rough to receive sub base including water tightness test with filling of water for continuous 48 hours complete.
M&L Plain Cement concrete in foundations, filling and mass-concrete type D2 1:4:8 (40 mm graded aggregate) complete.
M&L for Plain Cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate to fix hold fast including use of form work complete .
M&L for Plain Cement concrete type B1 1:2:4 (20 mm graded aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges including use of form work complete.
M&L for providing precast cement concrete louvers and jallies, 50mm thick (measured solid), type B0, 1:2:4 using 12.5mm graded aggregate including all mouldings and set in CM 1:4 uptp 6m hight complete.
M&L for Nominal mix reinforced cement concrete type Bo 1:2:4 (12.5mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete.
M&L for Nominal mix reinforced cement concrete type Bo 1:2:4 (12.5mm graded aggregate) in column, pier, pillars beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete.
M&L for Nominal mix reinforced cement concrete type Bo 1:2:4 (12.5mm graded aggregate) in lintel, lintel beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete complete.
M&L for Providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including chamfers, weatherings, throat- ing etc. and setting in CM 1:4 with joints to match complete.
M&L for Providing reinforced cement concrete nominal mix type Bo 1:2:4 (12.5mm graded aggregate) in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary form work as required complete.
Demolition brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars, etc. complete
M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement Mortar 1:6 complete.
M&L Half Brickwork with sub class ‘B’ bricks straight or curved to any radius in half brick thick walls built in CM 1:4 complete
M&L for Use and waste formwork for rough finished flat surface of concrete to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete.
M&L for Use and waste formwork for rough finished flat surface of concrete sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete..
M&L for Use and waste formwork for rough finished flat surface of concrete sides of pillars, posts, struts, piers, columns and stanchions etc. complete..
Taking down chowkats or frame with shutter (without taking off shutter from the frame) n.exc 1.5sqm each and remove from site complete
Taking down chowkats or frame with shutter (without taking off shutter from the frame) Exc 1.5 Sqm but n.exc 4.00 Sqm each and remove from site complete.
Taking down chowkats or frame n.exc 1.5 Sqm each and refixing in the same opening complete
Taking down shutter of any description exc 1 Sqm and n.exc 2 Sqm each and remove from site complete
Taking down and refixing of shutter in the same opening of any description exc 1 Sqm but n exc 2 Sqm each complete
M&L for 35mm thick factory made Flush shutters, solid core construction, with block board core and plywood face panels, comercial type 1.0mm thick (veneered on both side) with decorative choice laminated type 1 (factory laminated), or surface finish, 6mm thick or external teak wood lipping fixed with nails, color and pattern as approved complete.
S&F 35mm thick 2nd class Hard wood Glazed and Skelton shutters, open rebated and prepared to receive glass, gauze etc (without sash bars) edges of framing plain, chamfered or rounded, fitted with cut, mitered and moulded beads for securing glass etc, sizes of members of shutters as specified in SSR Part-I, Section 8, clause 8.20(a) and fitted to chowkats complete.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm prelam PVC sheet reinforced with MS square tube, supplying and fixing in opening as per specification and drawing and matching with door shutter shade. The door frame shall be tied to the wall using 75/100mm long MS screw complete.
S&F 30mm thick factory made both sides prelam panel PVC door shutter consisting of frame made out of MS tubes of 19 gauges thickness and size 19mm x 19mm for stiles, top and bottom rails, MS frame shall have a coat of steel primer of approved make and manufacture. MS frame shall be covered with 5mm thick heat moulded prelam PVC C channel size 30mm thickness, 70mm width, out of which 50mm should be flat and 20mm shall be tappered in 45 degree < on either sides forming stiles and 5mm, 95mm wide prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115mm wide. prelam PVC sheet out of which 75mm shall be flat and 20mm shall be tappered on both sides to form lock rail. Top rail, bottom rail and lock rail shall be provided either sides of the panel 10mm (5mm x2) thick 20mm wide cross PVC sheet shall be provided as gap insert for top rail, and bottom rail paneling of 5mm thick both side prelam PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with 7mm (5mm+2mm) thick 15mm wide. PVC sheet beading on inner side and jointed together with solvant cement adhesive, an additional 5mm thick PVC strip of 20mm width is to be stuck on the interior side of C channel using PVC solvant adhesive etc. complete .
S&F of Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. Complete
S&F of Powder coated aluminium window/ventilator shutters, side hung/sliding type aluminium sections including necessary joining cleats, sash bars, glazing clips rubber neoprene packing, anodised aluminium snap beading, screws and grill etc as per manufactures instruction & trade practice complete.
M&L for mild steel TMT bars 10mm dia and over, cut tolength, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L for mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete.
M&L for Framed work such as grills, gratings, etc. with ends of bars shouldered and / or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete
S&F for Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for sunken treatment of WC/Bath, providing & laying APP based polymeric membrane of minimum weight of 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms / sqm) over a coat of bituminious / polymerized primer confirming to IS-3384 @ 0.30 Ltrs/Sqm by torch application with side over laps & longitudinal joints over laps etc as per manufacturer instructions complete.
M&L for cutting grooves in roof brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete
M&L for water Proofing treatment to roof slabs by applying one coat of bituminious / polymerized primer confirming to IS-3384 @ 0.30 Ltrs per Sqm, and laying actetic polypropylene (APP) modified membrane pre fabricated , reinforced with non woven polyester, of minimum 3.50 Kg/Sqm 3 mm thick (minimum) with minimum 75 mm side overlaps and minium 100 mm end overlaps and applying one coat of aluminium paint @ 0.11 Kg/Sqm over APP membrane complete
M&L Plain cement concrete 100mm thk, type D2 1:4:8 (40 mm graded stone aggregate) in sub base of flooring complete.
M&L for 25 mm thick Plain cement concrete in flooring type Bo, 1:2:4 (12.5mm graded aggregate) with & including water proofing compound (WPC) @3% by weight of cement for laying floor tiles complete.
M&L 75 mm thick Plain cement concrete type C2 1:3:6 using 40mm graded stone aggregate in plinth protection to be finished even and smooth without using extra cement including forming joints and filling with bituminous filler material complete.
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm , as in floors etc set over and including high performence adhisive manufactured by somani ezifix tile adhisive or equivalent mixed in cement as per manufacturer instruction and jointed with polymer modified cementetious grout manufactured by somani ezy grout or equivalnet of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 complete (Tile pattern and decoration shall be as suggested)
M&L for non skid colour ceramic tile 7 to 8 mm thick area of each tile joint free exceeding exceeding 0.11 sqm but not exceeding 0.18sqm, as in skirting / dado etc set over and including high performence adhesive mixed in cement as per manufacturer instruction and jointed with polymer modified cementItious grout of pigment matching to tile color including screed bed or bedding layer of mortar 15 mm thick for laying floor finishes with CM 1:6 complete (Tile pattern and decoration shall be as suggested)
M&L for Glazed ceramic coloured walls tiles in vertical surfaces 300 x 450 x 6mm to 7 mm thick set over and including high performance adhesive mixed in cement as per manufacturer instruction and jointed with polymer modified cementitious grout of pigment, matching to tile color including rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles complete (Tile pattern and decoration shall be as suggested).
M&L for 16 to 18 mm thick machine cut green marbel stone in single piece in riser of steps, skirting, dado, window (Jambs/Cills), and pillar laid over cement screed and jointed with base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing including 10mm thick plastering in CM 1:4 complete
M&L for machine cut kota stone slab flooring 20 - 25mm thick set over and including high performence adhesive mixed in cement as per manufacturer instruction and jointed with polymer modified cementitious grout of pigment matching to tile color including screed bed or bedding layer of mortar 15mm thick in CM 1:6 for laying floor finishes complete
M&L for machine cut kota stone slab 20 - 25mm thick in skirting, riser etc set over and including high performence adhesive mixed in cement as per manufacturer instruction and jointed with polymer modified cementitious grout of pigment matching to tile color including 10mm thick rendering for screed bed on vertical surface of wall or concrete surfaces in CM 1:4 to receive wall tiles complete.
complete removal of existing water proofing treatment including plaster and concrete padding, roughening of concrete surface, cleaning and washing down the surface with water and removing debris / rubbish out side MD land and M&L for 50 mm avg thick PCC padding in cement concrete type B0 (1:2:4) using 12.5 mm graded stone aggr with & including water proofing compound @2% by weight of cement to be finished surface even and smooth without using extra cement for laying of WPT complete.
M&L for brushing with neat cement slurry @ 3Kg/Sqm
M&L for Cement concrete tiles 25cm x 25cm x 22-25mm thick, machine pressed; laid over & including15mm thick cement screed in CM 1:6, set, jointed and pointed in neat cement slurry with & including WPC @ 3% by wt of cement in floors / roof top complete
Taking down cement plaster on brick / concrete surface incl scrubbing down with water etc. and M&L for Rendering 10 mm thick on fair faces of brick work or concrete surfaces of Internal wall in CM 1:6 for finished even and smooth (without using extra cement) complete
Taking down cement plaster on brick / concrete surface incl scrubbing down with water etc. and M&L Rendering in two layer on fair faces of brick work or concrete sur-faces of External wall with 5mm thick in CM 1:4 mixed with & including WPC @ 3% by wt of cement to be finished even and smooth without using extra cement over 10 mm thick rendering in CM 1:6 complete.
Taking down cement plaster on brick/concrete surface incl scrubbing down with water etc.and M&L for Rendering 10 mm thick on fair faces of brick work or concrete sur-faces of ceiling in cement mortar 1:4 for finished even and smooth (without using extra cement) complete
M&L Rendering in two layer on fair faces of brick work or concrete surfaces of compound wall 5 mm thick in CM 1:4 mixed with & including WPC @ 3% by wt of cement to be finished even and smooth without using extra cement over 10 mm thick rendering in CM 1:6 smooth without using extra cement complete.
M&L for 15 mm thick plaster in sunken portion with CM 1:3 mixed with & including water proofing compound @ 2% by weight of cement plaster surface to be finished even and smooth without using extra cement for sunken treatment of WC / Bath complete.
M&L for 10 mm thick plaster on roof surface with CM 1:3 mixed with water proofing compound @ 2% by weight of cement plaster surface to be finished even and smooth without using extra cement complete.
M&L for preparing new plastered surfaces of wall and applying two coats of oil bound distamper over and including a coat of 1 to 1.5mm average thick wall care putty and one coat of primer complete.
M&L for complete removal of old existing treatment completely by scrapping and or rubbing of wall and applying two coats of oil bound distamper over & including a coat of 1 to 2mm average thick wall care putty and one coat of primer complete.
M&L for preparing new plastered surfaces of wall and applying two coats cement base paint over a coat of primer on external wall complete.
M&L for preparing old decorated surfaces of wall applying one coat of cement base paint on external wall complete
M&L for preparing new plastered surfaces of ceiling and applying three coats of white wash complete.
M&L for preparing old plastered surfaces of ceiling and applying one coat of white wash on ceiling to match the existing surfaces complete.
S&F 4.00mm thick figured glass, pin head type and glazing with rubber beading or with glazing clips complete .
M&L for preparing new steel surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete.
M&L for preparing new wooden surface of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete.
M&L for 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in shutter complete.
M&L for MS 300mm, ordinary rat tail rod patter springs, including roller and roller plate complete.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete.
S&F 300 mm aluminium alloy anodised sliding door bolts, with hasp and staple (bolt type) not less than 12mm dia with and and fixing clips of sheet cast or extruded section and fixing bolt and sliding bolt of extruded section or cast aluminium and fixed to wooden door shutters complete
M&L for 100mm butt hinges of stainless steel grade 202, 14 gauge thickness, medium weight of approved make fixed with pressed steel door frame / PVC door frame with screw complete .
S&F 200mm long Aluminium anodised barrel tower bolt of extruded section and fixed complete
S&F 150 mm size extruded aluminium alloy handles, febricated type anodised complete
S&F 125 mm aluminium alloy handles, cast type anodised complete.
S&F 150mm aluminium anodised barrel tower bolts of extruded section and fixed complete.
S&F 100mm aluminium anodised Hasp and Staple, safety type, with mild steel hinge pin including bolt to hinge plate and fixed with screw complete.
S&F in repairs 20mm dia brass chrom plated tubular towel rail complete.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land complete.
S&F 16 mm dia CPVC pipes SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete
S&F 15mm bore galvanised mild steel tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors complete.
Taking up or down 20mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land complete.
Refixing of old galvanised mild steel medium grade of dia 20mm bore tubing and connections in new or old position with all new fittings and fixed to walls and ceilings or laid in floors complete.
S&F 20mm bore galvanised mild steel tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors complete.
Taking up or down 25mm bore steel tubing and connections, including cleaning for refixing or removal out side MD land complete.
S&F 25mm bore galvanised mild steel tubing medium grade with all fittings and fixed to walls and ceilings or laid in floors complete.
Refixing of old galvanised mild steel medium grade of dia 25mm bore tubing and connections in new or old position with all new fittings and fixed to walls and ceilings or laid in floors complete.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with stack clamps of FI 50 x 5mm and 16mm dia round stays,incl bolts, nuts and securing ends of stays to wall or roof complete.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors.
S&F in repairs 110mm bore PVC (SWR) bends any radius.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall with stack clamps of FI 50 x 5mm and 16mm dia round stays,incl bolts, nuts and securing ends of stays to wall or roof complete.
S&F in repairs 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floor .
S&F in repairs 75mm bore PVC (SWR) bends any radius.
S&F in repairs 110mm PVC (SWR) vent cowl
S&F in repairs 75mm PVC (SWR) vent cowl
S&F in repairs vitreous China squatting pan of Orissa pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including P or S trap etc and provision of lean concrete bedding complete.
S&F in repiars 110mm PVC (SWR) WC connector with lip ring.
S&F in repairs 110mm PVC (SWR) WC connector bent type to fit WC outlet.
S&F in repairs 110mm PVC (SWR) junction single, (Single T, 'Y' type) equal or unequal with access door.
S&F in repairs 75mm PVC (SWR) junction single, (Single, 'Y' type T) equal or unequal all as access door specified and as directed.
S&F in repair 75mm PVC (SWR) floor trap, plain with CP grating including jointing with solvent.
S&F in repairs 15mm bore chromium plated fancy type bib tap long body, screwed down, high pressure for iron pipe or for brass ferrule
S&F in repairs stop valves/Angle valve15mm bore fancy type chromium plated screwed both ends for iron pipe or for unions and fixed
S&F in repairs 25mm dia bore gun-metal, globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed
S&F in repairs 125mm dia chromium plated shower rose with swivel joints including fixing to GI union complete
S&F in repairs 32 mm bore low density polyethylene pipe (LDPE) of pressure rating 6 Kgf/cm2 as in waste pipe
Dismantling of water storage tank of 500 ltrs capacity and S&F 500 Ltrs Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete
Disconnecting existing tanks of 500 ltrs to 1000 ltrs capacity, setting aside (or lowering if required) for repairs cleaning etc and hoisting if required reconnecting and re fixing in position. Cleaning and removing of all scale and dirt etc from tanks and from mouths of circulating pipes etc. including all necessary fittings if required complete
S&F in repairs Ball brass valves, for 25 mm bore of pipe high pressure, with polythene float and fly- nut complate, screwed for iron pipe or brass ferrule and fixed complete
S&F in repair vitreous china Wash hand basin, white , flat back size 550 x 400 mm except taps, CP waste coupling but incl brackets complete.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm complete
S&F in repairs Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including suitable waste coupling and waste pipe complete.
S&F in repairs CP wall mixer three in one system for mixing hot and cold wather screwed down for iron pipe 15 mm bore and fixed complete .
S&F in repairs CP Centre hole Wash Basin mixer three in One 15 mm bore pipe complete.
S&F in repairs 32 mm dia stainless steel waste coupling for wash hand basin complete.
S&F in repairs stainless steel wall mounted plate rack of size 880 x 880 X 220 mm and thickness of sheet not less than 0.50mm with provn for keeping plates and other crockery fixed with screw and rawal plug etc on wall complete
Providing and fixing in repairs factory made 18 (+0.7mm) thick PVC sheet one sided pre laminated sheet cabinet shutter of density 600 kg/m3 bent at 90o and finished all edges at all level for making edges, Lipping/bending or 0.5 mm thk PVC sheet lipping at all four edges using bonding tape etc. as per Manufacturers's speciifcations & instructions complete.
M&L for Forming 65mm deep x 10mm thick contraction (dummy joints), filled with sealing compound grade "A" complete.
M&L for preparation of reinforcement and apply corrosion resisting coat rust remover in two coats, suitable time to be provided between coats according to manufacturers instruction to resist further detoriation of reinforcement etc complete
M&L for apply Epoxy Bonding agent (2 part solvent free epox based bonding agent) to old concrete surface / mortar before applying the plastering to the surface complete
S&F in repairs 25mm dia stainless steel 202 grade tubular curtain rod complete
S&F in repairs stainless steel socket fancy type with bracket for 25mm dia stainless steel tubular curtain rod (design of socket shall be as approved) complete
Providing and laying super fluid microconcrete (roff crete repairs or equivalent) in beam bottoms, columns, slabs etc, including mixing with 5mm to 10mm size aggregates, waterproof ply wood / steel plate shuttering, pouring, temping, consolidating, curing etc as per manufacturer's specification and instructions complete. Note :- This item shall be paid on actual consumption of Micro concrete.
M&L for complete removal of loose / cracked concrete incl reinforcement if required, from RCC roof projection, chajja, fins, facia, roof bands etc and making good with PCC (1:11/2:3) type A0 (using 12.5 mm graded stone aggregate) in any slab and in any position & to be finished the surface even and smooth with out using extra cement including necessary form work and welding / binding of reinforcement (including reinforcement) if required and applying three coat of white wash / two coat of cement base paint to match with the existing surface complete.
Dismantling MS Work such as steel window/ventilators including guard bars grill etc complete
Taking down existing UNSV copper/aluminium point wiring (light, fan, socket or power) and M&L for concealed point wiring complete with 1.5 Sqmm single core multistranded copper conductor PVC insulated and unsheathed FRLS cable 1100 volts grade, conforming IS 694 & color code in conduit system of wiring, drawn in including medium grade PCV conduit not less than 20 mm dia concealed, including cutting chases, finising of slote by means of cement mortor making good to the existing surface of the wall & touching with the existing colour of wall with three coats and making good disturbed surface complete, sunk in pressed steel terminal boxes of required size not less than 1.6mm thick factory made and factory painted with top cover 3 mm thick plastic laminated sheet6 fixed with brass screw and washer with all accessories including single core solid conductor copper 1.5 sqmm size solid PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same conduit complete for One light point controlled by one switch 6 Amp one way.
All as described as per Item No 132 above but for One fan point controlled by one switch 6 Amp one way
All as described as per Item No 132 above but for One exhaust fan point controlled by one switch 6 Amp one way
All as described as per Item No 132 above but for One bell point controlled by one switch 6 Amp one way
All as described as per Item No 132 above but for One 3 pin switch socket combination 6 amp on the independent board.
All as described as per Item No 132 above but for One 3 pin switch socket combination on same board with other switches.
All as described as per Item No 132 above but for point wiring with 2.5 sqmm single core multi stranded copper conductor PVC insulated & unsheathed FRLS cable 1100 volt grade and 1.5 sqmm PVC insulated and unsheathed FRLS cable 1100 volt grade with multi stranded copper conductor for earth wire for 15/16 amp multi purpose socket combination point on independent board.
All as described as per Item No 132 above but for One light point controlled by two 2 way switches, with cables 1.5 sq. mm size
S&F in repairs MCB DB SPN 12 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V for fixing of MCBs/Isolators/RCCBs etc complete
S&F in repairs MCBs DB TPN 4 way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240/430V complete
S&F in repairs MCBs SPN 5 to 40 Amps 240 / 415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
S&F in repairs MCBs SP 5 to 40 Amps 240 / 415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 Sqmm terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
S&F in repairs RCCBs double pole 240Volt, AC type 30mA as per IS-12640-2 integrated label holder, ergonomic design with colour cooled ON/OFF indicatio o dolly with front face indication for earth leakage fault having IP020 protected terminals of size 35 sqmm of 25 Amps capacity complete as per CAT Part No 411326 DX3 of make : Legrand or equivalent
S&F in repairs MCB TPN 4pole 63 Amps 240/415 Volts 10 KA finger proof terminal, bi-connect termination, label holder, 35 mm² terminal capacity, insulated sliding shutter, large two position dolly, ISI marked to be fixed on DB complete.
M&L in repairs switch piano flush type single pole, one way 6amp, 240V complete.
M&L in repairs switch piano flush type single pole, two way 6amp, 240V complete.
M&L in repairs switch socket combination 2 in 1, 5 pin 6 amp, 240 V complete
M&L in repairs switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type 240 V complete
S&F in repairs stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. complete
S&F in repairs ceiling rose 65 x 17mm three terminals 230/250V complete
S&F in repairs lamp holder, PVC / Polycarbonate type and back plate suitable for batten fitting along with 09watt LED Lamp complete
M&L in repairs flush type bell push 6 amp, 240V duly marked for bell complete.
M&L in repairs Electronic ding dong bell AC 230V single pole complete
S&F in replacement sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete
M&L for in repairs Sub main wiring with FRLS two single core PVC insulated and unsheathed fire retardant multi stranded copper conductor cable 1100 volt grade IS-694, marked of 4.0 Sqmm size drawn through and including not less than 25 mm dia PVC conduit medium grade ISI marked and conduit junction boxes, terminal boxes and accessories such as tees, bends, elbows, reducers, bell mouth tube ends fixed to the surface of wall / ceiling including one run of 4.0 sqmm PVC insulated and unsheathed FRLS multi stranded copper conductor cable for earth wire continuity conductor complete. NOTE: Two runs of single core 4 sqmm and one run of 4.0 sqmm copper FRLS cable as earth continuity conductor and suitable size conduit with accessories shall be measured as one length.
S&F in replacement 18W LED tube light along with fixture etc. Complete.
S&F in replacement 10W LED bulk head complete.
Supply, Fixing, Testing & Commisioning in replacement of 2' 10W Mirror LED Batten with system lumen output of 1000 lumens. System Efficacy should be > 85lm/ W. PF>0.95 Housing of luminaire should made of die cast alumunium including connecting fitting with not less tha 0.5 sqmm 3 core flexible stranded copper conductor wire upto ceiling rose complete. Model-ENDURALINEAR NEOBS1W LED 830SPCWH of Havells or equivalent
S&F in replacement 25W wall security light LED type complete. Make- Havells, Model ENDURA PEARL SL25W LED 757 SASYTOPC or equivalent
M&L for replacement of 25 mm bore light grade GI pipe fixed as bracket, on poles any type, not less than 1.0 m long and bent to shape as required with sutiable clamp made out of 25x4mm Flat Iron duly fixed 12mm dia nuts, bolts, washers etc. suitable for steel tubular / PCC pole complete.
Supply, fixing, testing & commissioning of Exhaust fan 225 mm sweep, aluminum rust proof body & blades, with louvers for protection from birds, 230 Volt AC supply, rated power input not more that 45watt, with louvers fixed outside bldg for auto opening and closing connecting up including provison of cable from ceiling rose to fan complete. Similar to Crompton Greaves model No Trans Air 9" Note: Old UNSV ceiling fans will be deposited to AGE E/M office through RV
S&F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep with louver etc. Complete. Note: Old UNSV ceiling fans will be deposited to AGE E/M office through RV
S&F Ceiling fan with electronic type regulator and accessories 230 V,1200 mm sweep. BEE 5 star rated complete. Note: Old UNSV ceiling fans will be deposited to AGE E/M office through RV
S&F in repairs PVC rigid conduit medium grade suitable for telephone wiring concealed on wall floor ceiling etc of size not less than 20 mm including all fitting like bend elbow socket reducers etc. Complete.
S&F PVC Junction boxes 1-4 way with cover suitable for PVC rigid conduit of size 20 mm dia complete.
S&F RJ11 telephone outlet with shutter similar to Schneider cat Part No P4011_DG or equivalent.
S&F TV socket similar to Schneider cat Part No P4500_DG or equivalent.
Taking down carefully and refixing of energy meter any make or capacity etc complete at old/new place after rewiring etc. Complete.
M&L in repairs Earthing complete with galvanized steel plate electrode 60 cm x 60 cm x 6 mm surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25 meter below ground level with top edge of the earth plate at a depth of not less than 1.50 meter below ground level connected to galvanized iron or steel earth wire, 4 mm dia (No. 8 SWG) by means of bolts, nuts, check nuts and washers of galvanized iron, earth wire protected by galvanized steel pipe 15 mm dia (Light grade) & connected to main switch or main control board all as shown in electrical plate No. 5 of 1991 Part I & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers 20 mm dia pipe (Light grade) for watering, protection pipe, funnel, wire mesh, PCC chamber in cement concrete (1:3:6) type C-I, 40 mm thick RCC (1:2:4) type B-1 cover and CI frame etc. NOTES: - (i) The unit rate includes earthing wire and protection pipe up to 7.5 metre.(ii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe bends elbow shall be deemed included in the rates.
M&L for sand cushoning to cable with river sand and punning to provide required cover for UG cables complete
M&L brick protection cover to electric cable with sub class 'B' bricks laid dry and flat abutting each other with gap between adjascent not exceeding 10mm complete.
Supply and laying in replacement in trenches or passing through pipe, 1100 volts grade heavy duty cable with XLPE insulated aluminium conductor served with an inner sheathing of PVCtape armouredwith galvanised steel wire or tape and overall PVC sheathed 16sq. mm 4 Core nominal cross section in service connections complete .
M&L in repairs galvanized steel tubing light Grade of 40 mm dia protection of cable fixed to pole / walls with all necessary fittings and fittings and fixed with 25x4mm FI clamps, bolts, nuts and washers etc complete.
M&L in repairs galvanized steel tubing light Grade of 40 mm dia protection of cable laid in floors, road crossing ducts with all necessary fittings and fittings and fixed etc complete.
Dagli Engineers
Shree Vaishno Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .