Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹53.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹57.4 L+₹4.1 L (7.68%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹59.4 L+₹6.0 L (11.3%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹60.7 L+₹7.4 L (13.8%)Rejected-Finance DOOR NO 50 13 27 14 FLAT NO 14 PADMAJA APARTMENTS SEETHAMMAPETA VISAKHAPATNAM 530016 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530016 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹62.8 L+₹9.5 L (17.8%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
30 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER RnD SECUNDERABAD
CHIEF ENGINEER RnD OPP JUBILEE BUS STATION PICKET SECUNDERABAD-500003
PROVISION OF CERTAIN WORKS AT DEMARCATED NSTL LAND VISAKHAPATNAM
2020_MES_374171_1
CERD/VIZ/TOKEN/04 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
NSTL VISAKHAPATNAM
CLASS C CATEGORY a(i) and as per tender documents
8 documents required · 8 mandatory
₹1,000
AGE I RnD NSTL VISAKHAPATNAM
₹1.2 L
Yes
18 Feb 2021
2 Sept 2020
8 Jan 2021
2 Sept 2020
30 Dec 2020
17 Nov 2020
3 Sept 2020 - 9 Sept 2020
60 days
Amount
Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out in hard/dense of soil, complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, tubular poles or laying of pipes, or for removal / laying of cables etc., not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out in hard / dense soil, complete all as specified and directed.
Excavating over areas, n exc 1.5m deep and getting out in hard / dense soil, complete all as specified and directed.
Excavating over areas, exc 1.5m, but n exc 3.0m deep and getting out in hard / dense soil, complete all as specified and directed.
Returning, filling in, in soils, including spreading, levelling, watering and well ramming in layers not exceeding 25cm., complete all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Removing excavated soil to a distance exceeding 250m, but not exceeding 500m and depositing where directed at a level not exceeding 1.50m above the starting point, complete all as specified and directed.
Hardcore of broken stone or boulders of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Plain cement concrete (1:4:8), type D2 (using 40mm graded stone aggregate), 100mm thick as in sub base for hardstanding, complete all as specified and directed.
Plain cement concrete (1:2:4), type B1 (using 20mm graded stone aggregate), 75mm thick as in base course of floors, complete all as specified and directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound, complete all as specified and directed.
Sand cushioning under floors of paver blocks / tiles compacted by using plate compactor or other suitable mechanical method etc., complete all as specified and directed.
Machine pressed precast conctete interlocking paver blocks / tiles any shape and size, with grey cement and pigment, any shape and size, confirming to IS 15658-2006 of 60mm thickness, M-35 Grade, laid over 50mm thick sand cushioning, complete all as specified and directed. Make: As approved by AGE(I) Note:- Sand cushioning shall be measured and paid separately under respective item of BOQ.
Plain cement concrete (1:3:6) type C2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete or grouting of angle post, complete all as specified and directed.
Reinforced concrete pipe of 450mm bore, class NP2, laid and jointed complete with collars including testing after the pipes are laid, complete all as specified and directed.
Brick work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6), complete all as specified and directed.
Plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) as in copings and the like including weathering, slightly rounded or chamfered and throating including use of necessary form work complete all as specified and directed.
Rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement based paint over a coat of cement primer, complete all as specified and directed.
Plain cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete, complete all as specified and directed.
Mild steel TMT bars (CRS bars) 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia, complete all as specified and directed.
Mild steel TMT (CRS bars) bars 5mm dia and over upto and including 10mm dia as in stirrups or spacers, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Reinforced cement concrete M30 (Design mix) (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc., basement slabs, under-reamed piles and mass concrete, complete all as specified and directed.
Reinforced cement concrete M30 (Design mix) (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified and directed.
Reinforced cement concrete M30 (Design mix) (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; pile caps, grade beams and similar work; vertical or to batter, rough finished surfaces of concrete, complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings etc., rough finished surfaces of concrete, complete all as specified and directed.
Formwork to to sides of pillars, posts, struts, piers, columns and stanchions of square, rectangular or polygonal, rough finished surfaces of concrete, complete all as specified and directed.
Rendering 10mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coats of weather proof exterior emulsion paint over a coat of exterior primer, complete all as specified and directed.
Rolled mild steel Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc., (cut to ordinary lengths i.e. within 20mm of the length indicated), conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete, conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Preparation of new or previously untreated steel and iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Taking down, existing rusted concertina coil, barbed wire and connecting MS angle supports of any description, complete all as specified and directed.
Providing and fixing concertina coil fencing with punched tape concertina coil 600mm dia, 10m openable length having 50 Nos rounds per 6 metre length (before streching) on and up to 3m height wall fixed to 'Y' shaped angle iron brackets, stud tied with GI staples and GI clips to retain horizontal, including necessary bolts or GI barbed wire tied to angle iron with reinforced barbed tape (R.B.T)/spring core (2.5mm thick) wire of high tensile strength of 165Kg/Sqcm with tape (0.52mm thick) and weight 43.478gm/m, complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed.
Cast iron water meter, 40mm size, bulk enclosed type, flanged end/with threaded external bore, sockets, unions and necessary fixing acessories and testing, complete all as specified and directed. Make:- DASMESH / KRANTI / BELTANTO / FLOWTECH / WATFLUX
XLPE insulated, armoured, heavy duty electric LT cable, with aluminium conductor, 1100 volts grade, ISI marked as per IS-7098, cross-sectional area 240sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
XLPE insulated, armoured, heavy duty electric LT cable, with aluminium conductor, 1100 volts grade, ISI marked as per IS-7098, cross-sectional area 185sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
XLPE insulated, armoured, heavy duty electric LT cable, with aluminium conductor, 1100 volts grade, ISI marked as per IS-7098, cross-sectional area 150sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed.
XLPE insulated, armoured, heavy duty electric LT cable, with aluminium conductor, 1100 volts grade, ISI marked as per IS-7098, cross-sectional area 120sq.mm 3.5 core, laid in trenches / on poles / walls including provision of suitable hardware accessories, connecting up, testing on completion and commissioning, complete all as specified and directed. Note for Sl item Nos. 38.00 to 41.00 here-in-before:- Excavation, earth work, sand cuhoning, PCC cable protection covers, GI protection pipe etc., shall be measured and paid separately under respective items.
Un-reinforced precast concrete cable cover, class LV, Type I, flat of size 250 mm x 150mm x 40mm, complete all as specified and directed.
Spreading of natural, clean and dry river sand in trenches for cable protection, complete all as specified and directed. Note:- Punned thickness shall only be measured and paid.
Cutting of road/hardstanding to a size of 30cm in width and n. exc 90cm in depth for laying of protection pipe/cable including spreading, levelling, watering and well ramming in layers and providing PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) for the top 100mm layer, complete all as specified and directed.
GI tubing light grade, galvanised with all fittings including short lengths, ffixed to ceilings and concealed in walls with and including provision of suitable size of clamps including making necessary chases in walls and making good disturbed surfaces to match with the existing or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 80mm bore of pipe, complete all as specified and directed.
GI tubing light grade, galvanised with all fittings including short lengths, ffixed to ceilings and concealed in walls with and including provision of suitable size of clamps including making necessary chases in walls and making good disturbed surfaces to match with the existing or laid in floors, complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc.,), 40mm bore of pipe, complete all as specified and directed.
Supply, install, connect, test and commissioning of LT control panel outdoor, cubical, self supported, manufactured from CPRI approved makes, both side openable, ventilations on both sides with wire mesh, dust and vermin proof etc., fabricated out of 3 mm thick CRCA sheet, comprising of bus bar chamber, cable galleries, separate compartment for each incoming and out going switch gear etc., duly powder coated, mounted/fixed on and including MS angle iron stand/frame 40 cm height from FFL, fabricated out of using MS angle iron of size 50x50x6mm duly painted with two coats of black enamelled synthetic enamel paint over a coat of red oxide primer duly grouted in PCC (1:3:6) type C2 (using 40mm graded stone aggregate) foundation, control wiring with multistranded PVC insulated copper conductor cable not less than 1.5 Sqmm, suitable size/capacity of aluminium strips for switch gear connection from main bus bar, earth bus stirp of 32x6mm size for entire length of panel, suitable size of SS gland with gland plate and aluminium lugs/thimbles for all incoming/out going cable etc., complete all as specified and directed with and including accommodating following :- (i) MCCB 4 pole, 415 Volts, 200 Amps rating, rupturing capacity 25 KA thermal magnetic release, adjustable over load and short cicuit protection-01 No. (In coming) (ii) MCCB 4 pole, 415 Volts, 125 Amps rating, rupturing capacity 25 KA thermal magnetic release, adjustable over load and short cicuit protection-01 No. (Out going to Technical work shop) (iii) MCCB 4 pole, 415 Volts, 63 Amps rating, rupturing capacity 16 KA thermal magnetic release, fixed over load and short cicuit protection-01 No. (Out going to existing LT Panel-1)
SL. ITEM NO. 47.00 CONTD… (iv) MCCB 4 pole, 415 Volts, 40 Amps rating, rupturing capacity 16 KA thermal magnetic release, fixed over load and short cicuit protection-01 No. (Out going to existing LT Panel-2) (v) Timer switch (Auto switching device operating on real time) digital type with min. switching time of 1 sec, having wide range of switches week & day programme with reserve 30 min with ML2 contactor including MCB TPN 16 Amps -01 set (vi) LED type Phase Indicator with controlling fuses for RYB-04 sets (One for incoming and three for out going) (vii) Digital type multifunctional panel meter KWH, Ampere, Voltage, Frequency, PF - 01 No (viii) Electrolyte Aluminium bus bar PVC colour sleeved 400 Amps capacity TPN mounted on hygroscopic insulator duly colour coded RYB & Green sleeves-01 set
Earthing provided in replacement complete with GI earth plate electrode 600mm x 600mm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth strip of 32 x 6mm size by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 40mm dia GI pipe 'medium grade', watering pipe 20mm dia GI pipe 'medium grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL, and connected to earth plate including necessary excavation & earthwork, PCC (1:2:4) type B-1 earth chamber, applying three coats of white wash including CI pit cover of size 30 x 30cm etc., complete all as shown in Electrical Plate No.3 connected to earthing test point, including testing on completion, complete all as speciified and as directed. Note:- (a) Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and CI cover. (b) Contractor shall submit test results of earthing.
Street light, LED light fitting of capacity of not less than 45Watts, IP 65 with 100 lumen/watt and inbuilt surge protection and with all acessories including disconnecting and taking down of existing old vintage type street light fittings of any size and capacity complte all as specified and directed. Make:- Crompton Cat No. LSTS-45-CDL-1 or Techno-commercially equivalent model in Bajaj / C & S / Philips
Energy meter, three phase trivector 240/440 Volt 10-60A whole current meter of class 1 along with CTs of ratio 100/5A/50/5A (for installation in existing LT Panel which is feeding from NSTL power source) complete all as speciified and as directed. Make:- Schneider Cat No. EM6436H or Techno-commercially equivalent model in Secure / L & T / HPL INDIA / Havells / Elmeasure / Conzerv
CIVILEC ENGINEERING WORKS
Ruchira Associates
P SRINIVASA RAO
Raghavendra Constructions
SAI KRISHNA ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .