Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.2 L+₹2.3 L (10.5%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹26.2 L+₹4.3 L (19.5%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹28.5 L+₹6.5 L (29.7%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹29.7 L+₹7.7 L (35.3%)Rejected-Finance DOOR NO 15 1 141 BHAVANA ENCLAVE 1 NEAR HOTEL GRAND BAY MAHARANIPETA NOWAROJI ROAD VISAKHAPATNAM 530002 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530002 | L5 | Rejected-Finance Being not L1 |
Tender Value
₹41 L
EMD Value
₹82,000
Closing Date
16 Mar 2021, 6:00 pmClosed
Garrison Engineer Utility-I Visakhapatnam
Garrison Engineer Utility-I Near Samudrika Naval Base Post Visakhapatnam -530 014
REPAIR / MAINT OF VCBS,RMUS AND CERTAIN LT PANEL BOARDS INCLUDING REPACEMENT OF UG CABLES AT INS CIRCARS AND ND(V) AREA UNDER AGE E/M NO-I OF GE(U-I) VISAKHAPATNAM
2021_MES_423195_1
8298/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineer Utility-I Visakhapatnam
class D
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility-I
₹82,000
Yes
12 May 2021
17 Feb 2021
17 Mar 2021
17 Feb 2021
16 Mar 2021
3 Mar 2021
Amount
M&L for maintenance of 11KV CT chamber by disconnecting all 3 phase cable connections, extended bus bars and from VCB Bus and taking out from panel mounted position, testing for proper functioning, body leakage, checking & cleaning / decarbonising of all contact points of CT, epoxy body and Bus bars, complete CT chamber using hot blower and CTC solution, applying backlot (Red) solution to the CT body and refixing the same CT to original position, re-connection of all existing cables, extended bus bars, testing complete all as specified and directed. Note:- CT if replaced shall be measured and paid separately as supply only.
Maintenance, servicing, cleaning of Busbar chamber of each VCB including connecting bus bar from CT to Bus bar, spout, support insulator, opening of covers, using CTC and clean cloth and hot air blower/vacuum cleaner, checking for any loose contact, tightening of all nuts & bolts, refixing all covers, replacement of defective bus spout complete all as specified and directed Note :- Bus spout if replaced shall be measured and paid separately as supply only.
M&L for setting of 3 phase IED of any type/Make from 11kV HT panel, cleaning the contacts , IED configuration , Calibration & Testing of all the measuring & protection devices viz., CTs, Relays and Meters at site. Testing of all the trip functions of the relays after final current settings by simulating fault current by CT secondary injection test set , checking of current transformer , rectification of defects in control wiring for proper tripping of CB during actual system fault conduction through relay & Tripping coil. Adjustment / setting to plug and time multiplier settings of IED to achieve the discrimination in tripping , tune/synchronies upstream breaker relay settings-installation of relay, testing & commissioning etc. complete all as specified and as directed.
M&L for Collecting necessary required data & peak load details from IED of any type/Make from 11kV HT panel , Transformer full load details during peak hours. Relay Setting Calculations & Co-Ordination Study. Unit Protection Setting of Transformers. Feeder wise settings has to be furnished & Report with Firm Recommendations to be submitted Down Stream Power distribution (Complete 11 KV system) overall co-ordinations of time need to be achieved. Adjustment / setting to plug and time multiplier settings of IED complete in all as specified and as directed.
Note: The Contractor has to arrange necessary testing Kits, testing equipments, tools etc. Rental rates for the testing/calibration kits & connected equipments are deemed to be included in the quoted rate. Testing & tuning shall be carried out onsite with testing equipments in presence of Engr-in-Charge by Qualified , Licenced personal and test results shall be signed both by the contractor and Engineer-in-Charge and kept on recordin to the satisfaction of the Department.
Supply only Resin Cast CT dual core, CT ratio- 100/50/5A-5A For 800A , 11 KV VCB panel.
M&L for maintenance/servicing of PT unit 11Kv / 110V by disconnecting and taking out from panel mounted position, checking & cleaning of fixed and moving contact points, cleaning/ decarbonising of bus bar connections, resin cast PTs using hot blower, CTC solution, applying backlot (Red) solution to the epoxy PT body, tightening of all nuts, bolts, washers, and refixing the same PT to original position, testing complete all as specified and directed.
Taking down HT switch gear (Vacuum circuit breaker ) of capacity 11 KV 250/350 MVA comprising of following repairs, overhauling, servicing, carrying out preventive maintenance and refixing the same after repairs/ overhauling:
(a) Tripping off the breaker, lowering the breaker with raising/lowering handle and pulling out the breaker complete from the panel along with the trolley for servicing/inspection/overhauling
(b) Servicing/Inspecting/checking of automatic safety shutter operation for serviceability and replacement of spares if required.
(b) Servicing/Inspecting/checking of circuit spout and circuit spout connections for RYB phases and replacement of spares if required.
(c) Dismantling and checking of cross bar assembly, fixed contacts and current carrying parts of the breaker, trolley, insulated assembly and checking lamination with clamps, epoxy spout, isolator assembly etc.
(d) Setting, reassembling, cleaning, adjustment of fixed contacts, main contact, arcing contacts and chamber baffle pot assembly, moving contact for proper setting of auxiliary contacts operating mechanism.
(e) Servicing/Inspecting/checking of secondary sockets/bus bar earthing plugs/earthing sockets and replacement of spares if required.
(f) Checking, setting and adjustment of lowering and raising operation of the breaker trolley.
(g) Decarbonising of bus bar and connected items
(h) Lubrication and greasing of all moving parts of the trolley, stopper bolt for proper operating and closing of shutter gear, isolation resistance of trolley of with vacuum interrupter assembly.
(J) The inspection of HT switch gear shall involve:- (i) Inspection of truck & hoist assembly. (ii) Inspection of tank assembly & barriers. (iii) Inspection of assembly & components of solenoid assembly. (iv) Inspection of assembly & components of dependent mechanism. (v) Inspection of assembly & components of spring box mechanism. (vi) Inspection of motor mechanism spring charge assembly (vii) Inspection of assembly of trip unit & related components
Notes: (i)The servicing includes for bus bar duct chamber, cable alleys and connecting accessories (ii) The rate quoted shall be deemed to include for necessary T&P, nuts, bolts, washers, gasket, insulation tape, compound, painting of VCB panels with approved colour including lettering details all as per existing etc. to put in to the VCBs and panels in serviceable condition, testing and commissioning all as specified and as directed by the Engineer-in-Charge. (iii) Major spares like Breaker bushings, vacuum interrupter assly, bus bar spout, bus bar spout connections, circuit spout/circuit spout connections/buffer fixed contacts, moving contacts, tank assly/barriers, solenoid spares, dependent/spring mechanism/ motor mechanism, trip unit etc. will be measured and paid separately under relevant items of Schedule 'A'. However the rate quoted shall be deemed to include for any other minor spares require replacement. (iv)The servicing shall be carried out by Authorised service centre as approved by GE
M&L for rectification of faults and retrofit of electrical circuit of 11 KV VCB comprising of the following accessories with suitable IED's by checking CT/PT healthiness , proper programming of multifunctional meters and replacement of defective components & wiring with FRLSH multistrand PVC insulated copper conductor 1100 volts grade as per existing size of wire complete all as specified and directed Note :- Required new components will be measured and paid separately under relevant items.
i) Numerical feeder protection relay - 1 No.
ii) Trip circuit supervision relay - 1 Nos
iii) DC supply supervision relay - 1 No.
iv) High speed tripping relay - 1 No.
v) Auxiliary relay- 1 Set
vi) Multifunction meter, Digital type (Displaying A, V, PF, Hz, KVA, KW, KVAR, KWh, Karsh etc.) Class 1 - 1 No.
vii) Digital Voltmeter , Ammeter - 1 Set
viii) Indication Lamps & Annunciator - 1 Set
ix) Control Switches & Wiring with appropriate colour coding , complete which are required for smooth / satisfactory operation of CRP as per scheme requirement
x) T‐N‐C Switch (Breaker Control Switch) - 1 Set
xi) Circuit label - 1 No.
Supply , install ,Testing , Commissioming of Numerical feeder protection relay 50/51N (Earth over current), 67P (3Ph directional over current), 67N (Earth fault directional over current), 51V (Voltage controlled over current), 37 (3Ph under current), 46 (Negative Phase sequence over current), 59N (Residual over voltage), 32 (Directional power protection under/over active/Reactive power), 81 (Under over over Frequency ), 49 (Thermal Overload),79 (Auto resue),50BF (Circuit breaker failure direction),Cold pickup,Inrush blocking including taking down old relay complete all as specified and directed by Engr-in Charge.Relay will be on Modbus Protocol.(Make:- Schneider of Model Micom P-127 protection relay, 110V, 5A, type-BAOZ112Ca1 or its equivalent in ABB/SEIMENS)
Supply and fixing High Speed Master Trip Relay
Supply and fixing the following for Metering :-
Supply and fixing the ndication lamps for C.B. ON/OFF/TRIP/Trip Circuit Healthy and Unhealthy/Spring Charged
Supply and fixing the following for Control switches & Control Wiring :-
T‐N‐C Switch (Breaker Control Switch)
Trip Circuit Healthy Push Button
Control wiring with appropriate colours
Local Remote switch
Supply & fixing closing coil assembly 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one complete all as specified and directed. Make- Schneider Part No- ECO39SN134900FN
Supply and fixing tripping coil 110 V DC to Schneider make 11KV VCB incl necessary connection testing complete incl dismantling taking down unserviceable one all as specified and directed. Make- Schneider Part No- ECO39SN134100FN
Supply and fix including dismantling taking out unserviceable vacuum interrupter of suitable for VCB of capacity 2500 Amps all as specified and directed. Make-Schneider Part No-VSLVG4002-01
Supply and fix including dismantling taking out unserviceable Breaker Nylon Wheel, For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make:- Schneider Part No-MVIA00054-01
Supply and fix including dismantling taking out unserviceable spring charging Universal motor with gear box 220V AC For 800A to 2500A Schneider make 11 KV VCB complete all as specified and directed. Make: Schneider Part No-MVIJOO157-02
Supply and fix including dismantling taking out unserviceable Release Lever (Nylon ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- MVIJ00010-01
Supply and fix including dismantling taking out unserviceable Buffer (For Opening Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- MVIJ000980-1
Supply and fix including dismantling taking out unserviceable Buffer (For Closing Spring ) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- MVIJ00056-01
Supply and fix including dismantling taking out unserviceable Rectifier unit (Monoblock) for spring charging motor For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- ERC-A-A00DC-001
M&L for replacement of damaged space heater, 230V AC supply , 100 watt inside 11 KV HT VCB cable chamber including necessary connection, testing complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable HRC Fuse-Pt HT Side (VTF-11, 3A) For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- EHF-A-EV 000-001
Supply and fix including dismantling taking out unserviceable Control Circuit HRC Fuse : 2 A , 4 A , 6 A , 1 0A complete all as specified and directed.
Supply and fix including dismantling taking out unserviceable Service/Test Position Limit Switch 1NO+1NC For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make-Schneider Part No- ESW-B-AAA00-001
S&F multifunctional meter with LED display, accuracy class-1, e- navigator, including dismantling taking down unserviceable one and connection, programming, testing complete all as specified and directed. Make- Elmeasure/ L&T/Schneider
Supply and fix including dismantling taking out unserviceable Isolating Contact For 800A to 1600A Schneider make 11 KV VCB complete all as specified and directed. Make- Schneider Part No- MVIK00190-01
Supply and fix single (Red-Blue) phase bus bar spout suitable for 800 Amps to 1250 Amps VCB complete all as specified and directed. Make Schneider Model No MEP-39- 32185
Supply and fix single (Y) phase bus bar suitable spout for 800 Amps to 1250 Amps VCB complete all as specified and directed. Make: Schneider Model No MEP-39-32186
Supply and fix Drive Beam suitable for 11 KV VCB 800 to 2000 Amps complete all as specified and directed. Make : Schneider Model No MCS27S0298700PN
Supply and fix Epoxy Body suitable for 11 KV VCB up to 1250 Amps complete all as specified and directed. Make: Schneider Model No MEP3953022000FN
Supply and fix Dive Rod assembly with contact block VG2 suitable for 11 KV VCB up to 1250 Amps complete all as specified and directed. Make: Schneider
Supply and fix CT Spout suitable for VCB 800 to 2500 Amps 25 Ka chamber insulating bus support epoxy insulator of dia 95mm and 125mm length complete all as specified and directed. Make: Schneider
M&L for repairs/servicing of 12 KV outdoor RMU's of any make with mechanism comprising of the following:- (a) Cleaning of RMU for dust, oxidising and decarbonising with CTC. (b) Repair/servicing of spring loaded operating mechanism. (c) Repair/servicing of spring charging motor. (d) Checking, repairing & servicing of gearbox, auxiliary switches, spring, limit switch etc complete. (e) Checking & repairing electrical and mechanical operations (f) Lubrication all moving parts with petroleum jelly & cleaning all bushing insulators with CTC (g) Tightening of all mechanical connections of mechanism (h) Proper Tightening all LV connection of VCB.
Note :- (i) New components if any are required will be measured and paid separately as supply only under relevant items here in after. (ii) The rate quoted shall include RMU transportation to Factory location for rectification.
Supply only following components of RMU catered under sl item No 35.00.
Isolator / Switch Cat Part No 51193845FA
D/B Circuit-breaker Cat Part No 51193845FC
D/B Circuit-breaker Under voltage Coil Kit 24 Vcc/Vdc Cat Part No AAV29672
D/B Circuit-breaker Trip Coil Kit 24 Vcc/VdcCat Part No 51009541FA
Circuit-breaker Closing Coil Kit 24 Vcc/Vdc Cat Part No SPK0008SM6
Switch Motorization Block 24 Vcc/Vdc Cat Part No 51008240FA
Circuit-breaker Motorization Block 24 Vcc/Vdc Cat Part No 51009476FA
MOTOR FOR MOTORIZED MECHANISM 24 Vcc/Vdc Cat Part No 51193931FA
110-125Vcc/Vdc and 110-127 Vca/Vac 50/60H Cat Part No z51193931FC
I Switch Position Indication Cat Part No 51008250FA
Circuit-breaker Position Indication Cat Part No 51009574FA
CB Fault Tripping Indication Cat Part No 51009574FA
Limit Switch - Motor Disabled when CB Trips Cat Part No 51009573FA
MITOP Trip unit Cat Part No 51193845FE
Relays VIP 300 LCat Part No L03143428FA
FLAIR 22D Lithium Dua Fault Passage Indicator(FPI) Cat Part No EMS58352
VIP-300 LL CT ( 200/1) Cat Part No 51007003F0
VPIS Standard : 3.3 to 7.7 kV Cat Part No BBV14380
Heat Resistor for I Switch Operating Mechanism51191956FA
Heat Resistor for D/B Circuit-breaker Operating Mechanism Cat Part No 51191956FC
RM6 Operating Handle Big Size Cat Part No 3725708
RMU Evolution at Factory for rectification and submitting report along with suggested rectifications with requred material.
Shifting, transportation of RMU from Dolphin hills to Apprentice school including removing of all connection from existing panel and refixing to new location connecting all incoming and outgoing cables. including necessary foundation as per manufacturers recommendations, cable terminations etc., complete all as specified and as directed by Engineer-in-Charge.
M&L for Earthing complete with glavanised iron or steel earth plate electrod 60 cm x 60 cms x 6.0mm thick burried directly in ground surrounded by charcoal or coke and salt (earth pit not less than 2.25 metre deep below ground level) with top edge of earth plate at a depth of not less than 1.5 metre below ground level connected to GI or steel earth wire 4mm dia by means of nuts, bolts, check nuts & washers, protected by GI pipe 15mm bore (light grade) and connected to maint switch board or main control board complete all as specified and indicated in electrical plate No 5 of SSR-1991 Part-I including testing on completion.
Supplying and laying synthetic Rubber insulated mats 2.5mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m
UV POWER TECH
MVV Prasad
VENKATESWARA ENGINEERS AND CONTRACTORS
SRIESWARI ENTERPRISES
M/S CHANDRA ENGINEERS AND CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .