Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance PLOT NO 1076 BEHERA SAHI NAYAPALLI BHUBANESWAR 751012 | KHORDHA | ODISHA | 751012 | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance 2RA 135 PRESS COLONY KHARVEL NAGAR UNIT III BHUBANESWAR 751001 | BHUBANESWAR | KHORDHA | ODISHA | 751001 | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹1.4 L
EMD Value
₹2,760
Closing Date
20 Jun 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DIRECTOR NISER
NISER Bhubaneswar, Jatni
Provision for additional Power point fixing for UPS installation and UPS point wiring for the lab instruments in Green House building
2024_NISER_810406_1
NISER/IWD-ELECT/GH/24-25/01
Open Tender
Electrical Works
Works
15 days
NISER Bhubaneswar, Jatni
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2,760
Yes
21 Jun 2024
7 Jun 2024
21 Jun 2024
7 Jun 2024
20 Jun 2024
8 Jun 2024
Supplying and fixing 100Amp MCCB sheet steel enclosure, on surface or in recess, for 100 amp 4 pole MCCB with connections, testing and commissioning etc. as required. Make: Legrand/Hager/C&S
Supplying and fixing 63 A rating, 4pole, 415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required in the existing DB.Make-Legrand/Hager/Schnieder/Havells
Supply and fixing of 2AC Digital timer for the for single phase AC unit installaed in the room. Make: Aircon/Equivalent
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way, Double door VTPN DB Make-Legrand/Hager/Schnieder/Havells
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp TP MCB fixing in existing DB Make- Legrand/Hager/Schnieder/Havells
Supplying and fixing following way, Single Pole and Neutral DB, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door SPN DB Make-Legrand/Hager/Schnieder/Havells
Supplying and fixing 40A rating, 240/415 V, 10 kA, "C" curve, Four Pole MCB (miniature circuit breaker) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required in the existing DB. Make-Legrand/Hager/Schnieder/Havells
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amp RCCB Make-Legrand/Hager/Schnieder/Havells
Supplying and fixing 20 A to 32 A rating, 240/415 V, 10 kA, "C" curve, SP MCB (miniature circuit breaker) suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required in the existing DB. Make-Legrand/Hager/Schnieder/Havells
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Make: Polycab/Universal/Finolex/RR
Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.2 X 4 sq. mm + 1 X 4 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR
Supply & Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 6 sq. mm + 2 X 6 sq. mm earth wire. Make: Polycab/Universal/Finolex/RR
KISLAY KUMAR
M/S DEEPANA ELECTRICALS & CONSULTANCY
M/s. PRACHI ELECTRICALS
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .