| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED BEING LOWEST QUOTED | |
| 2 | L2₹20.9 L+₹1.0 L (5.13%)Rejected-AOC | L2 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED | |
| 3 | L3₹21.0 L+₹1.1 L (5.63%)Rejected-AOC | L3 | Rejected-AOC NOT ACCEPTED DUE TO HIGHER RATE QUOTED |
Tender Value
Refer Docs
EMD Value
₹41,200
Closing Date
11 Aug 2022, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIRS TO BLDG NO P 124 PROVN OF BASKET BALL COURT AND CERTAIN MINOR WORKS AT MIL STN DHRANGADHRA
2022_MES_540531_1
GE(A)/GNR/TOKEN/38 of 2022-23
Open Tender
Civil Works
Item Rate
120 days
MIL STN DHRANGADHRA
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹41,200
Yes
24 Sept 2022
23 Jul 2022
13 Aug 2022
23 Jul 2022
11 Aug 2022
30 Jul 2022
23 Jul 2022 - 28 Jul 2022
Amount
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out hard/dense soil all as specified and directed.
Removal of excavated soil material n exc 50m and depositing where directed at a level n exc 1.5 m above the starting point completed all as specified and directed.
M&L Hard core (broken stone) of gauge n exc 63 mm, deposited, spread & levelled in layers n.exc 15cm thick, watered and levelled to a true surface.
M&L for granite/trap Stone kerb of roughly squared stones of sectional size 10cm x 30cm and not less than 45cm length, all surfaces hammer dressed so that the maximum depression from a straight edge held against the dressed surface shall not exceed 20mm jointed in cement mortar 1:6 and struck flush.
S&F 35 mm thick, 2nd class hard wood factory made, plain, framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Taking down chowkats or frame of any descrip tion exc 1.5 Sqm each and n.exc 4 Sqm (without taking off shutters from the frames) complete as specified and directed.
S&F mild steel rolled section Fe-410-W(Gde E-250), quality 'A' as in post, main and cross beams, rafters, purlins connected to common rafters fixed with angle iron clips or other connecting plates complete all as specified and directed.
S&F, MS angle iron framed work as in doors or gates of angle or other section conforming to Fe 290(Gde E-165) with gusset plates, rails, braces, etc complete including hanging also fastening and fixing complete as specified and directed.
S&F WS Basketball Pole fix, • Basket ball pole fix international standard board size: 180cm x 105cm, 20mm transparent acrylic board, with padding standard pole extention 2.20 mtr, made of 6 inch square pipe, with heavy dunking ring & nylon net, pole padding on front, best quality pu spray paint complete all as specified and directed. Make/Brand: WEB SPORTS or equivalent
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding wall, fixed with self tapping screws as specified.
M&L 75 mm thick cement concrete type D-2 (1:4:8) using 40 mm graded aggregate for sub base of flooring all as specified and directed.
M&L for 50mm thick cement concrete type B1, 1:2:4 (20mm graded stone aggregate) as in floor finishing cement concrete surfaces even and smooth with using extra cement complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular), area of each tiles exceeding 0.11 sqm but not exceeding 0.18sqm, in floors etc. set & jointed in net cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete as specified and directed.
M&L, Non-skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18sqm, in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick backing coat in CM 1:4 complete all as specified and directed
M&L for 50mm thick cement concrete 1:3:6 type C1, using 20mm graded stone aggregate as in plinth protection, finishing cement concrete surfaces even and smooth without using extra cement complete all as specified and directed.
Taking down cement or cement lime plaster, any description on stone walls etc incl raking out joints hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering 10mm thick cement plaster 1:6 on stone masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in (1:3) cm on fair faces of ceiling complete all as specified complete all as specified and directed.
M&L for rendering 15mm thick cement plaster 1:4 on stone masonry surface or surface other than fair face of brickwork surface finished even and smooth without using extra cement complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of new surfaces of plastered or unplastered of wall and application of three coat of white washing complete all as specified and directed.
M&L for preparing old plastered or un-plastered walls surfaces and applying one coats of white wash on walls complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L complete removal of existing treatment of wall and preparation of old plastered or Un plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement primer complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces and applying three coats of white wash on ceilings complete all as specified and directed.
M&L for preparing old plastered or un-plastered surfaces and applying one coat of white wash on ceilings complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) not exc 0.5 sq.m from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones complete all as specified and directed.
S&F Glazing with sheet, 3mm thick, ordinary quality and glazing with oil putty and glazing pins in squares not exceeding 0.5 Sqm in each pane complete all as specified and directed.
M&L for preparation of old wooden surface of any description, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surface of any description, over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new steel surface of any description exc. 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for, such as plinth protection, roof padding etc complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling of asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified and directed.
Taking down carefully unserviceable copper/aluminium point wiring (Light, fan, socket or power) complete including unserviceable fittings and fixtures such as switches, ceiling roses, pendents, regulators, sockets, lamp holders, brackets, except ceiling fittings, bulk head fittings, tube light fittings etc. and making good the disturbed surfaces of walls, floors, etc. complete all as specified and directed.
Taking down carefully old UNSV submain wiring of any type/any size removing material to store for keeping in safe custody or for taking credits (credit for above items should be made as per condition seperately).
M&L for wiring with and including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. complete all as specified and directed for the following :-
(a) One light/fan point controlled by one switch
(b) One 3 pin, 5 Amps, socket outlet on the same board controlled by another switch.
(c) One multi pin 5 Amps, socket outlet on Independent board.
M&L for wiring with and including multistranded copper conductor 2.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number drawn in and including medium grade PVC casing and capping double lock type 32mm in size, fire resistant, ISI marked including with its fittings and fixtures such as tees, bends, elbows, junction boxes, etc. including multistranded copper conductor 1.5 Sqmm (nominal cross sectional area) single core, PVC insulated, unsheathed FRLS cable 1100 Volts grade, ISI marked with valied CML number as continuity earth wire and including pressed steel sunken concealed terminal box with 3mm thick industrial laminated sheet cover for mounting switches, sockets and fan regulators etc. for one 3 pin, 15 Amps socket outlet point on independent board complete all as specified and directed.
S&F, lamp holder, PVC/Polycarbonate, with back plate suitable for batten fittings complete all as specified and directed
S&F, switch piano, flush button, single pole, one way, 5 Amps complete all as specified and directed
S&F, switch piano, flush button, single pole, one way 15 Amps complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and directed
S&F, socket outlet, 2 in 1, 3 pin, 15 Amps and 5 Amps flush type complete all as specified and directed
Taking down the existing ceiling fans complete with down rods and refixing the same with supply of new down rod of size 15 mm dia made of GI pipe med grade aprox 1 metre length incl flexible wire all as specified and directed.
S&F, ceiling fan step type regulator,AC 230 Volts complete all as specified and directed.
S&F, in repairs, sheet metal distribution board, SPN, 8 way 240 Volt, double door factory made and tested complete, protection class IP-42 suitable for mounting MCBs, isolator with 200 A tinned copper bus bar complete all as specified and directed
S&F, ceiling rose, 3 terminal , any shade, of PVC/Polycarbonate, isolated body complete all as specified and directed
S&F, in repairs, miniature circuit breakers, type curve ‘B’ , 10 KA, SP, 6 to 32 Amps complete all as specified and directed.
S&F, in repairs, miniature circuit breakers, Single pole and neutral, type curve ‘B’ 10KA, 32 Amps 230 Volts. complete all as specified and directed.
S&F, in repairs, sub-main wiring with 2 single core, 4 Sqmm PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper multi stranded conductor drawn in and including PVC casing and caping of 32mm size including drawing one run of PVC insulated, unsheathed, 1100 Volts grade, FRLS, copper conductor multi stranded, 4 Sqmm size as continuous earth wire drawn through and connected to main switch/DB and testing on completion complete all as specified and directed. Note: 2 runs of main conductor, one run of earth conductor and one run of PVC casing and caping shall be measured as one unit length
S&F, in repairs, LED light fitting, batten type, housed in extruded from powder coated aluminium, 18 watt for soft diffuser lighting with and including lamp and connecting up complete with white PVC insulated and PVC sheathed round flexible three core copper conductor cable of suitable size and testing on completion all as specified and directed.
M&L, in repairs, earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6mm thick buried directly in ground [earth pit not less than 2.25 metre deep below normal ground level] with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No. 3 of MES SSR Part I all as specified and testing on completion including provision of earth lead protected by 15 mm dia light grade GI pipe & watering pipe shall be 20 mm bore medium grade GI pipe including all excavation and earth work in any type of soil, PCC pit with RCC cover, char coal, salt, funnel etc complete. Note : Rate quoted by tenderers shall be deemed to include for following provisions;-[i]. Excavation & earth work in any type of soil including removing of surplus material upto 50 M.[ii]. PCC 1:3:6 type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC 1:2:4 type B1 cover 50x50 cm with 8mm TMT bars @ 10 cm C/C both ways with handles.[iii]. Main earthing lead from earth electrode to test point upto 7.5 mtr.[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs, charcoal & salt as reqd.[v]. GI protection pipe of size 15 mm bore light grade 7.5m.
S&F security light luminaries 25 watt with wall mounting bracket of suitable size and clamps, nut bolts etc.having pressure die cast housing with epoxy power coated dark graphite grey colour finish,prismatic polycarbonate cover with individual LED lenses-IP65 prewired Conforming to Crompton Cat Part No. LSTO-25-CDL or of equivalent make of wipro/Havells/Philips wipro.
Excavation in trenches in soft / loose soil n . exc 1.5 mtrs wide and not exceeding 1.5 mtrs depth for taking out / laying of under ground cables and getting out all excavated materials with bricks bats etc as directed .
Returning, filling in, trenches with soft/ loose soil including spreading levelling watering and well ramming in layers not exc 25 cm with excavated soil complete all as directed.
Removing surplus spoil to a distance not exc 50 mtr away and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified.
M&L for Sand coarse filling in trenches obtained from local river for cushioning of UG cable all as specified and directed .
Supply and laying well burnt best quality locally available bricks of good tolerance laid flat for protection of UG cable all as directed .
M&L tubing GI tubing light grade laying for protection of LT under ground cable of size 40 mm bore.
Supply, laying, connecting and testing of LT under ground electric cable 6 sqmm, 2 core,XLPE insulated armoured heavy duty with stranded aluminium conductor served with an inner heathing of PVC tape armoured with galvanised steel wire or tape 1100 Volts grade , laid in trenches or drawn through GI pipe or fixed to wall with providing suitable size of metal clamps, cable glands, aluminium lugs, GI nuts bolts and washers complete wherever required complete all as specified and as directed .
Supply, Installation & commissioning of 1.5 tone high wall split AC (hot and cold), inverter type (variable speed), heat pump, 4500 kcal/hr nominal cooling capacity, copper coil material condenser and evaporator with copper fin material, Eco-frendly Regrigerant, BEE star rating, remote control, including auto-restart, sleep mode, power saver, turbo cool, 4-way air swing, speed setting, humidity control, active carbon filter, anti-bacteria filter and cyclotron filter features, generally conforming to ISI Marked and 3-meter minimum length of copper pipe and suitable connecting electrical cable & outdoor unit metallic stand for installation and commissioning complete all as specified and directed.
S&F, Voltage stabilizer for automatic operation single phase nautrally air cooled indoor type and designed for input between 170 V to 250 V with output voltage stablized at 230 V Accuracy of ± 2.5 and caspacity 5 KVA including complete testing all as specified and directed for make of V-Guard or equivalent as approved by GE.
S&F, sheet metal enclosures, single-pole and deutral with a two-pin and earth plug and socket complete with one single pole, SPN MCB 20 Amp, 240 Volts complete all as specified and directed.
Bhumi Construction
Singh Engineer And Contractor
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .