Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹49.9 LAccepted-Finance | ₹49.9 L | 1 | Accepted-Finance Lowest one |
| 2 | 2₹50.4 L+₹44,622 (0.89%)Rejected-Finance | ₹50.4 L+₹44,622 (0.89%) | 2 | Rejected-Finance Higher than the Lowest one |
| 3 | 3₹53.3 L+₹3.4 L (6.74%)Rejected-Finance | ₹53.3 L+₹3.4 L (6.74%) | 3 | Rejected-Finance Higher than the Lowest one |
| 4 | 4₹55.7 L+₹5.7 L (11.5%)Rejected-Finance | ₹55.7 L+₹5.7 L (11.5%) | 4 | Rejected-Finance Higher than the Lowest one |
Tender Value
₹50.3 L
EMD Value
₹1.0 L
Closing Date
7 Mar 2022, 2:00 pmClosed
Ex. Engineer (E and M)-I, SDMC
SOUTH DELHI MUNICIPAL CORPORATION OFFICE OF THE EXECUTIVE ENGINEER (E and M)-I ROOM NO.2, NEAR GATE NO. 09, Dr AMBEDKAR STADIUM DELHI GATE, NEW DELHI-110002
SITC of Pumping Stations for supply of treated effluent water from Keshopur STP to various parks of Vikaspuri under west zone, SDMC
2022_SDMC_108332_1
EE (E and M)-I/SDMC/2021-22/06
Open Tender
Machineries/ Mechanical Engg Items
Item Rate
60 days
Ambedark Stadioum SDMC
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹1.0 L
17 Mar 2022
3 Mar 2022
8 Mar 2022
3 Mar 2022
7 Mar 2022
3 Mar 2022
Amount
Supply of Treated supply of effluent water from GG Block Vikaspuri to Dusshera Park F Block, Budhela Village park and Maharshi Dayanand Park Vikaspuri under west zone. P & F M.S.Black pipe C Class heavy duty confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of following Dia 65 mm
P & F M.S.Black pipe C Class heavy duty confirming to IS: 1239 Part-1(2004) with required nut bolts & packing sheet etc complete as required of following Dia 80 mm
P& F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia:-, 65 mm(8 mm thickness)
P& F of M.S. Flange with required nut bolts & packing sheet etc complete as required of Dia:-, 80 mm(8 mm thickness)
P& F of M.S. Blank Flange with required nut bolts & packing sheet etc complete as required of Dia 65 mm (8 mm thickness) along with one feet pipe of 65mm dia.
P& F of M.S. Blank Flange with required nut bolts & packing sheet etc complete as required of Dia 65 mm (8 mm thickness) along with two feet pipe of 65mm dia.
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:- 65 mm, 4.85 mm thick, 0.3 m
P& F of M.S. Bend with required nut bolts & packing sheet etc complete as required of following Dia:-80 mm, 4.85 mm thick, 0.3 m
Supply of corrugated & chequered rubber mat having thickness 12 mm and size in 1M X 2M
Providing and fixing of CI Swing Type Non Return Valve Flanged end as per IS 5312 Body cover -CI IS -210 ,GR FG 260 Door -CI IS -210 ,GR FG 260 body Ring - Bronze IS -318 Gr LTB2 door face Natural rubber Hinge Pin -SS ASTM A276 & type 410 Fasteners-CS IS 1367 CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) NRV 80 MM
P &F of Ball Valve with Flangeed end flowjet (Three piece design) of following size Ball valve 65 mm
Providing and fixing of Cast Iron Non rising sluice valve Flanged end as per IS Body cover IS -14846 , body dome - wedge-CI IS 210 ,GR FG260 Body & Wedge Rings -Bronze IS 318 GR :LTB2 Spindle -SS IS 6603 Gr 12Cr 12 gland Packing -Greasy Jute Packing fasteners - CS IS 1367 , CL -4.6/4.0 Gasket -Natural Rubber Flange Drilling -IS :1538,Table 4 & 6 (PN 1.6) SV 65 MM
P&F Antivibrating Cushy Foot Mounting of following size B-Series
P&F Water level indicator with real time info on App/Desktop having alarm configuration for critical conditions such as tank low and full etc. compatible with 230V, 50Hz AC supply etc including service and maintenance, servicing, cloud charge etc to keep the app functional for the period of one year i.e. during warranty perioid.
P&F Analog Water pressure gauge AISI 304 Stainless steel front 100mm diameter water tight case, 0 to 200 kg/cm2 along with connection with valve of size 12mm etc
SITC of Electrical Horizontal Centrifugal Pump Set with end suction single stage, back pull out typepump with CI impeller, SS Shaft and SS Sleeve, size 80X65 minimum 24Mtr Head and minimum discharge 40m^3/hr, with Min. 7.5 HP , 1450RPM, 3 phase, TEFC AC Motor and suitable coupling and guard for motor pump set along with MS base frame to handle the STP water for horticulture purpose.
Offload changeover switch four pole without SS Enclosure mounted in panel, with advance neutral conforming to IS:13947 (Part-3) complete as required 160 A
S/F installation of cubical panel board 16 SWG sheet M.S depth 30 cm to 60 cm with A1. bus bar and interconnection suitable for switch gears i/c and making foundation etc as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A,36KA,FPMCCB
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 A TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 63 A TP&N
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of following size . 4 core 50 sqmm
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of following size . 4 core 10 sqmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonary open duct as required. Above 35 sq. mm and upto 95 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 Sqmm.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 50 sq. mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/METAL pipe as required. Up to 35 sq.mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq.mm ( Clamped with 1 mm thick saddle )
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
Supply of XLPE insulated and PVC sheathed Al. conductor armoured cable confirming to IS 7098 ( Part -I ) / 1988 as required. (a) 2 x 10 sq mm
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Single pole
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 Amo
S.I.T.Cof 150 W LED flood light luminiare fitted with lens made of pressure die cast aluminium housing &toughened glass cover complete with the following specification as required (b)Total system voltage =150 watt +/-5% (c) Luminiare Efficiency =100 Lm/w(d) Power Factor >=0.95 ( e) Protection Class - IP -66
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm(NS)complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB &63 A double pole isolator(MCB/Isolator exluded )with neutral link duly shorting on DIN channelwith 2 nos.of clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required
S.I.T.C LED tube type luminaire 20 watt rating complete with Polycarbonate housing batten integrated electronic driver prewired with high efficiency LED with the following specifications.(A) Total system wattage 20 watt+/- 5% ,(B) Luminous efficiency >= 95 Lumens/watt, © Power factor >= 0.95
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supply of 15'' (380mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd
Installation of exhaust fan in the existing opening including making good the damage,connection,testing,commissioning etc.as required.(a) Up to 450 mm sweep
Supply,installation,testing & commissioning of single / three phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtrmtr,suction and delivery 25X25 mm
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer - in - charge. All works upto plinth level (For 04 Nos. main pump sets 0.6*1.2*0.33= 0.2376 cum each).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-50D or more.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, modular switch,modular plate,suitable GI Box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required..2x2.5 sq.mm +1x2.5 sq.mm earth wire
Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required. 2x 4 sq. mm + 1 x 4 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Operation along watch and ward of pumping station round the clock operation by providing by the APD(Assistant pump driver) at pumping station for a periof of 3 months for each pumping station (3Nos. per day for 180 days at three site) i.e. 1620 Nos.
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 100 mm width X 50 mm depth X 1.6 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 200 mm width X 50 mm depth X 1.6 mm thickness
Providing and fixing 4.5 kg Co2 type fire extinguisher sqeeze grip type , trolly wheel as well as wall mounting type complete in all respect with ISI mark i/c fixing arrangement etc as required as per technical specification attached .
Offload changeover switch four pole without SS Enclosure mounted in panel, with advance neutral conforming to IS:13947 (Part-3) complete as required 200 A
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A,36KA,FPMCCB
Supply of XLPE insulated PVC sheathed Aluminium conductor armoured cable 1.1 KV conforming to IS 7098/ (Part-I) of following size . 3.5 core 70 sqmm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 70 sq. mm (38mm)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
continental electricals
Avon Electricals
Super Power and Fire Enginer
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .