| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.3 LAccepted-AOC GE WEST BAREILLY | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹19.1 L+₹1.2 L (6.49%)Rejected-Finance 35 A 60 RAMPUR GARDEN BAREILLY UP | BAREILLY | BAREILLY | UP | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹19.2 L+₹1.2 L (6.78%)Rejected-Finance | L3 | Rejected-Finance Over all rates are higher than L-1. | |
| 4 | L4₹20.1 L+₹2.1 L (11.7%)Rejected-Finance WARD NO 5 THIRIYA NIZAWAT KHAN BAREILLY 243123 UP | BAREILLY | BAREILLY | UTTAR PRADESH | 243123 | L4 | Rejected-Finance Over all rates are higher than L-1. | |
| 5 | L5₹20.3 L+₹2.3 L (12.9%)Rejected-Finance C 3 SHAHDANA COLONY BAREILLY 243005 | BAREILLY | BAREILLY | UTTAR PRADESH | 243005 | L5 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
29 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE WEST BAREILLY
GE WEST BAREILLY
SPL REPAIRS TO BLDG NO P-13 (MAIN OFFICE) AND P-15 (OLD JCO MESS) OF JRC UNDER AGE B/R - II OF GE WEST BAREILLY.
2023_MES_584188_1
8095/C/E8
Open Tender
Civil Works
Item Rate
180 days
GE WEST BAREILLY
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE WEST BAREILLY
₹56,000
Yes
31 Mar 2023
3 Mar 2023
31 Mar 2023
3 Mar 2023
29 Mar 2023
17 Mar 2023
Amount
Dismantling of corrugated or semi corrugated asbestos cement sheets in roof covering complete all as specified and directed.
Dismantling of timber scantling 40 Sqcm and over in section, in any position as in unframed or framed work complete all as specified and directed.
Demolition of brick work or stone / boulder masonry including all quoins, arches, pillars, etc. built in cement mortar or cement lime mortar complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan exc. 6.00 m mean radius built in cement mortar 1:4 complete all as specified and directed.
M & L for brick work with fly-ash old size bricks having designation 75 conforming to IS-12894 (2002), straight or curved on plan and any radius in half brick thick wall built in cement mortar 1:4 complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling of wall and ceiling boards (fiber, pulp, insulation etc.) or insulation boards / slabs / blankets, any thickness including cover fillet complete all as specified and directed.
M & L for 4 mm thick E-Board classic (everest or equivalent) tiles for insulation and accoustic purpose 60cm x 60cm with and including powder coated galvanised iron snap grid made of 32x25x1.5mm thick Tee section and 32x25x1.5mm thick angle section with all hanging/supporting arrangements as in false ceiling and making good disturbed surface complete all as specified and directed.
Taking down cement or cement lime plaster from brick or stone walls etc. including raking out joints, hacking for keys, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in cement mortar 1:4 including mixing of water proofing compound as per manufacturer’s instructions on fair faces of brick work or concrete surfaces finished even and fair complete all as specified and directed. NOTE: - WATER PROOFING COMPOUND SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
M & L for rendering 15 mm thick cement plaster on fair faces of brick work or concrete surfaces with cement mortar 1:6 finished even and fair complete all as specified and directed.
M & L for rendering 5 mm thick cement plaster on cement concrete surfaces of ceiling with cement mortar 1:3 finished even and fair complete all as specified and directed.
M & L for applying 1 mm thick wall care putty on wall surfaces including rubbing down the surface with sand paper after getting dried to obtained an even and smooth surface complete all as specified and directed.
M & L for preparation of new plastered or previously untreated surfaces of walls and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M & L for preparation of old decorated surfaces of walls and applying two coats of distemper oil emulsion complete all as specified and directed.
M & L for preparing newly plastered or previously untreated wall surfaces and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M & L for preparation of newly plastered or un-plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M & L for providing plain cement concrete type B-1, 1:2:4, (using 20 mm graded stone aggregate), as in copings, bed block for embedding hold fasts, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles & throating as directed including necessary form work as required complete all as specified and directed.
Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in cement mortar complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including screeding 15 mm thick in CM 1:6 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.11 Sqm but not exc. 0.18 sqm, as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including plastering 10 mm thick in Cement Mortar 1:4 and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for Non skid ceramic coloured tiles 7 to 8 mm thick (Square or Rectangular) area of each tile exc. 0.06 Sqm but not exc. 0.11 sqm, as in floor etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile with and including screeding 15 mm thick in CM 1:6 and dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
M & L for glazed ceramic coloured tiles 450 mm X 350 mm X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile over and including plastering 10 mm thick in Cement Mortar 1:4 and dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), including removal of rubbish from the permises of site to low lying area complete all as specified and directed.
S & F of 16 to 18 mm thick granite (of any type and shade) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, set in over and including 15 mm thick cement screed in cement mortar 1:4 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
M & L for 18-20 mm thick and area of a tile exceeding 0.16 Sqm each, machine cut Kota stone slab as in flooring over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish over and including screeding 20 mm thick in CM 1:4 complete all as specified and directed.
M & L for 18- 20 mm thick machine cut Kota stone slab as in risers of steps, skirting, dado and pillar over cement screed bed, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including necessary grinding, rubbing, rounding to exposed edges and polishing in granite finish over and including plastering 20 mm thick in Cement Mortar 1:4 complete all as specified and directed.
Taking down chowkhats or frames area not exc. 1.50 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down chowkhats or frames area exc. 1.50 Sqm but not exc. 4.00 Sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed.
Taking down door or window shutter of any description not exc. 1 Sqm each complete all as specified and directed.
Taking down door or window shutter of any description exc. 1.00 Sqm but not exc. 2.00 Sqm each complete all as specified and directed.
S & F of 1.25 mm thick pressed steel frame of size 125 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc complete all as specified and directed.
S & F of 1.25 mm thick pressed steel frame of size 105 X 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plates etc. complete all as specified and directed.
S & F of 35 mm thick factory made flush shutter solid core construction with block board core and plywood face panels commercial type on both faces complete all as specified and directed.
S&F 35 mm thick (Batten thickness) 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze etc. divided into squares, without sash bars, edges of framing plain, chamfered or rounded, fitted with cut and mitered beads for securing glass etc. and size of the members of shutter is as specified in clause No. 8.24 (a) of MES schedule 2009, part – I (Specifications) complete all as specified and directed.
S & F of solid PVC door frame of size 50 mm X 47 mm made out of 5 mm thick plain coloured PVC sheet reinforced with mild steel square tube as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of 30 mm thick (style thickness) factory made solid panel PVC shutter consisting of frame made out of mild steel tubes for top and bottom rails, mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles and rails with suitable PVC sheets beading and joined together with solvent cement as per specification and drawing given on MES schedule Part-II (2020) complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators or partitions with one or more rebates including joining cleat etc. for fixing complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium door shutters, aluminium section weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos. in each door, hinges, anodised aluminum snap beading, screws etc. complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as one No. 150 mm long peg stay, two Nos. 100 mm size B-21 type hinges, one No. suitable size handle etc. complete all as specified and directed.
S & F of anodised powder coated (minimum thickness of powder coating 50 micron) aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 Kg per running metre including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S & F of 5.50 mm thick plain, ordinary quality sheet glass and fixed with rubber beading and glazing clips area exc. 0.5 sqm in each pane complete all as specified and directed.
M & L for 12 mm thick pre-laminated particle board, interior grade, pre-laminated both sides with decorative choice lamination and fixed with screws to timber framework complete all as specified and directed.
S & F of 4 mm thick plain, ordinary quality sheet glass and glazing with oil putty or glazing clips in any size complete all as specified and directed.
M & L for Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening complete all as specified and directed.
S & F of steel windows with pressed steel frame (size 95 x 45 x 1.25 mm ) side hung shutter including box type hinges with steel handle and steel peg stay with glazed openable shutter with glazing bar ( open out side ) and wire gauged openable shutter without glazing bar ( open inside ) dovetailed or welded complete all as specified and all as per DRG No TD/088 dt 07 Jan 2002. Note :- (i) Two shutters ie wire guaged and glazed shall be fixed in one composite frame and both shutter shall be measured as one unit. (ii) rate for filling PCC in frame deemed to be included in quoted rate of this item. (iii) MS grill shall be measured and paid seperatly under relevant item of schedule.
S & F of mild steel framed work such as grills, gratings etc. with ends of bars shouldered and / or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing, frame work of water tanks and similar work conforming to Fe-290 Grade E-165 complete all as specified and directed.
S & F of factory made steel window or ventilator fixed type with glazing bars complete all as specified and directed.
S & F of galvanised mild steel wire cloth, 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
S & F of 100 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 75 mm long mild steel butt hinges, medium weight cold rolled complete all as specified and directed.
S & F of 200 mm long aluminium anodised barrel tower bolt of extruded section complete all as specified and directed.
S & F of 150 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F of 125 mm long anodised aluminium handle, cast type complete all as specified and directed.
S & F of 300 mm long (Length of bolt) aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolt of extruded sections or cast aluminium alloy complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden / metal frames, glazed with oil putty or fixed with beads including punching or drilling out old glazing pins / spring clips and providing new glazing pins / spring clips complete all as specified and directed.
S & F of 3 mm thick plain, ordinary quality sheet glass and glazing with oil putty or fixed with wooden beads in square not exc. 0.5 sqm in each pane complete all as specified and directed.
M & L for preparation of new or previously untreated wooden surfaces exc. 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
Dismantling of water tank exc. 250 Litre but not exc. 500 Litre capacity complete all as specified and directed.
S & F of 500 Litre capacity triple layered, white coloured, rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of specifications as per MES Schedule 2009, Part-I and hoisted, fixed in position complete all as specified and directed.
Taking up or down 15 mm bore steel water tubing and connection complete all as specified and directed.
Taking up or down 20 mm bore steel water tubing and connection complete all as specified and directed.
S & F of 15 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
S & F of 20 mm bore steel water tubing medium grade galvanized with and including all fittings and fixed to walls and ceilings or laid under floors complete all as specified and directed.
Re-fixing of 15 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed.
Re-fixing of 20 mm bore old steel water tubing and connection in new or old position (wall, ceiling, floors etc) including cleaning of old pipes and provision of new GI fittings as required complete all as specified and directed. NOTE FOR ITEM NO. 67 & 68: - OLD STEEL WATER TUBING OBTAINED FROM DISMANTLING SHALL BE USED UNDER THESE ITEMS.
S & F in repairs 15 mm bore bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F in repairs 15 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs 20 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F of 20 mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gram) complete all as specified and directed.
S & F in repairs 450 mm long PVC connection with two Nos. PTMT nuts internally threaded and PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repair 25 mm dia grating doom with waste hole of PTMT (minimum weight 40 gram) complete all as specified and directed.
S & F in repairs125 mm size brass chromium plated shower rose with or with out swivel joint including fixing to steel pipe or union complete all as specified and directed.
S & F in repairs 15 mm bore fancy type, chromium plated stop valve, with long shank and cup (Concealed Type) cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs 20 mm dia brass chromium plated tubular towel rail ‘D’ type 60 cm long between flanges, including one pair of fixing brackets complete all as specified and directed.
S & F of 125 / 110 mm size PVC (SWR) gully trap, setting and jointing with solvent cement complete all as specified and directed.
S & F of 75 mm dia PVC (SWR) floor trap / nahani trap plain with grating including jointing with solvent cement complete all as specified and directed.
S & F of 32 mm size (Dia of discharge pipe) waste coupling of PTMT half or full threaded (minimum weight 45 gram) complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S & F in repairs vitreous china wash basin white, flat back, size 550 X 400 mm excluding taps, waste, chain and plug but including brackets, cutting for and pinning in as required complete all as specified and directed.
S & F in repairs vitreous China full stall type white urinal (excluding flushing cistern, flush pipe and waste pipe) but including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S & F of urinal valve auto closing system with built in control cock & wall flange valve 15 mm bore including urinal sperader of brass chromium plated as per Cat. Part No PRS-CHR-077 of Jaquar or equivalent as approved by GE complete all as specified and directed.
S & F in repairs 15 mm bore fancy type pillar tap, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘HOT’ or ‘COLD’ with long screwed shank and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs PVC low level white flushing cistern 10 litre capacity valve less, syphonic action type, complete with inlet, ball valve, float valve, bends, brackets, brass screws, handle etc and S & F of 32 mm dia PVC flush pipe of suitable length and making all connection and making good disturbed surface complete all as specified and directed.
S & F in repairs Vitreous china premium / 1st quality wash down water closet wall hung type EWC white/ ivory/off white (closed pattern) including all necessary accessories like rag bolts, gel gasket etc. but excluding flushing cistern & flush pipe complete all as specified and directed.
S & F in repairs water closet vitreous china squatting pan ‘Orissa’ pattern size 580 X 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe, anti-syphonic pipe etc. with and including setting the trap and pan in lime concrete bedding (one lime, two sand or surkhi and 5 aggregate) minimum 150 mm thick alround and finished just below level of rim of pan to receive the floor finishes complete including making good floor complete all as specified and directed.
Taking up or down AC/PVC rain water pipes any size and description complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
S & F of 110 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joint fixed to walls complete all as specified and directed.
S & F of 75 mm bore PVC (SWR) bend any radius complete all as specified and directed.
S & F of mild steel work as in framed brackets of not exc. 10 Kg each made of angle or Tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, riveting etc Fe-290 Grade E-165 complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-2, using 40 mm graded stone aggregate as in surface channel or drain complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified.
S & F of 25 mm dia stainless steel decorative curtain rod of any pattern, design & colour with end fittings and brackets complete all as specified and directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including cutting of reinforcement bars to facilitate demolition complete all as specified and directed.
M & L for providing reinforced cement concrete 1:2:4 (Nominal Mix) type B-1, using 20 mm graded stone aggregate, as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs, shelves and the like complete all as specified and directed.
M & L for mild steel TMT bars 6 to 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 5 mm dia and over up to and including 10 mm dia as in stirrups, spacer and binders, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc. 200 mm thick horizontal or slopping in rough finished surface of concrete complete all as specified and directed.
M & L for 75 mm thick cement concrete 1:3:6 type C-1, using 20 mm graded stone aggregate as in plinth protection laid to slop of 1:12, finished surface even and fair without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering where directed and providing 75 mm wide and 3 mm thick glass dividing strip inserted in position at every one meter and change of direction complete all as specified and directed.
M & L for cutting into existing manhole for connecting new drain, making good to pipe and rendering, cutting out existing benching for and forming branch channel (½ round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100 mm dia pipe complete all as specified and directed.
M & L for cement concrete 1:3:6, type C-2 (using 40 mm graded stone aggregate) as in bed to drain pipes of 100 mm bore including packing under and haunching against the sides of pipe after they are laid and tested complete all as specified and directed.
M & L for providing pre-cast cement concrete landing, cover slabs, chullah hoods, chajjas, shelves and similar items with plain faces in cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate and setting in cement mortar 1:6 complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for laying cables and getting out in soft/loose soil including trimming sides and forming bottom surface to the required level / slope etc complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm in each layer as in soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exc. 15 cm thick (Below or above ground level) complete all as specified and directed.
Supply only 3 mm thick and 38 mm wide glass dividing strips complete all as specified and directed. NOTE: - FIXING CHARGES OF THIS ITEM SHALL DEEMED TO BE INCLUDED IN THE UNIT RATE OF FLOOR.
M & L for 25 mm thick cement concrete type B-1, 1:2:4 (using 20 mm graded stone aggregate) as in levelling course over roof slab, finished even and smooth complete all as specified and directed.
M & L for providing APP based polymeric membrane minimum weighing 3 Kg per sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 Grams per sqm) laid by forced application over and including bituminous primer @ 0.30 Litre per sqm and hot blown bitumen @ 1.20 Kg per square metre after cleaning of roof surface complete all as specified and directed.
M & L for Heat resistance Aluminium paint over APP membrane @ 0.20 Kg per sqm complete all as specified and directed.
M & L for providing 100 mm thick cement concrete 1:3:6 type C-2 (using 40 mm grade stone aggregate) as in sub floor, sub base of floor complete all as specified and directed.
M & L for providing 40 mm thick cement concrete 1:2:4 type B-1 (using 20 mm thick graded stone aggregate) as in floor, laid in panels including fixing only glass dividing strips to divide the area in panels and inserted in position to conform to design and finishing top surface even and smooth with using extra cement complete all as specified and directed. NOTE: - GLASS DIVIDING STRIPS SHALL BE MEASURED AND PAID SEPARATELY AS SUPPLY ONLY.
S & F of 2nd class hard wood (SAL) scantling, clean sawn in any position and any description as in framed work complete all as specified and directed.
Taking down carefully aluminium / copper point wiring (light point, fan point, socket outlet point or power point) any type (batten, casing-N-caping, surface conduit or concealed conduit) complete with and including fittings and fixtures such as switches, ceiling rose, pendent, lamp holder, regulator, switch, socket outlet, shade conical etc. and making good disturbed surfaces of walls etc. as per existing finishes by plastering, repairs and distemper / white wash / colour wash etc. complete all as specified and directed.
Taking down carefully old unserviceable main switch / DB of any type, description from any position complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring any type and description and making good disturbed surfaces of wall, roof, floor etc. as per existing finishes complete all as specified and directed.
M & L for point wiring for one light point / fan point (Independent point), controlled by one, one way switch with 1.50 sqmm size, PVC insulated, unsheathed 1100 volts grade single core multi-stranded copper conductor cable (FRLS) drawn into and including non-metallic PVC conduit medium grade (not less than 20 mm dia) with and including its all necessary fittings and accessories fixed concealed with and including necessary chase cutting on brick / stone masonry walls and making good as per existing and sunk cast iron or 1.2 mm thick pressed steel terminal boxes for mounting fittings like switches, sockets, lamp holders, sketch fittings and covered with 3 mm thick plastic laminated sheet cover fixed with brass screws and cup washers including one continuous run of PVC insulated (green colour) 1.50 sqmm size stranded copper conductor cable (FRLS) as in earth wire and connecting all metal parts to common earth dolly complete all as specified and directed.
All as per item No. 121.00 here in before but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the independent board complete all as specified and directed.
All as per item No. 121.00 hereinbefore but wiring for one 3 / 5 pin 5 Ampere socket outlet point on the same board, controlled with other switches complete all as specified and directed.
All as per item No. 121.00 hereinbefore but wiring for one buzzer / bell point on the same board or independent board, controlled with other switches complete all as specified and directed.
All as per item No. 121.00 hereinbefore but wiring for one 3 / 6 pin 15 Ampere socket outlet point on independent board and wiring using with 2.50 sqmm size cables complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 5 Ampere complete all as specified and directed.
S & F of socket outlet 5 Ampere, 2 and 3 pins (TOTAL 05 PINS), flush type 250 volts AC complete all as specified and directed.
S & F of switch piano flush button single pole 230 volts, one-way 15 Ampere complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 5 and 15 Amperes flush type, 250 volts AC complete all as specified and directed.
S & F of bell push button type single pole one-way 5 Ampere complete all as specified and directed.
S & F of single phase call bell ‘DING DONG’ or MUSICAL, AC 230 volts single pole complete all as specified and directed.
S & F of ceiling rose PVC/ polycarbonate isolated body 3 terminal, 230 volts AC ISI marked, complete all as specified and directed.
S & F of electronic type fan regulator 230 volts, 150 watt, step type having five steps, socket type, hum free complete all as specified and directed.
S & F of Lamp holders PVC /polycarbonate insulated body modular type with back plate suitable for batten fitting/angle fitting complete all as specified and directed.
S & F as in replacement LED light of 1 x 10 watt T-5 Lamp type with electronic ballast of suitable capacity, clear acrylic cover including mounting on wall complete all as specified and directed.
S & F as in replacement surface mounting LED light fitting aluminium extruded T-5 batten, 20 Watt, 4 feet long including making electric connection with 23/0.0076 size three core PVC flexible cable complete all as specified and directed.
S & F as in replacement indoor decorative LED city-3 light fitting polycarbonate body with upper glove suitable for & including single 12 Watt LED lamp complete all as specified and directed.
S & F of LED Lamp12 Watt, 230 Volt AC integrated circuit complete all as specified and directed.
S & F of security light fitting, LED type, 20 Watt, 6000K, presure die cast housing with prismatic polycarbonate diffuser & individual LEDs as light source with integrated electronic driver complete with and including GI pipe mounting bracket made of 25/32 mm dia and 1.20 m long fixed to wall with and including nut bolts and GI clamps of size 50 x 6 mm as required including two coats of synthetic enamel paint over a coat of red oxide primer and making electric connection with three core of 23/.0076 rubber insulated copper cable from ceiling rose to connector ot street light complete all as specified and directed.
S & F of 1100 volts grade heavy duty 6.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 4.00 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
S & F of 1100 volts grade heavy duty 4.00 Sqmm size two single core PVC insulated (FRLS) copper multi-stranded conductor cable as in sub main wiring, drawn into & including PVC conduit medium grade not less than 20 mm dia including its all accessories & fittings, fixed concealed with and including chase cutting and making good the same as per existing specifications along with a continuous run of 2.50 Sqmm size stranded copper conductor PVC insulated (FRLS) (green colour) cable as earth wire complete all as specified and directed. NOTE: - TWO SINGLE CORE CABLES ALONG WITH EARTH WIRE AND PVC CONDUIT SHALL BE MEASURED AS ONE UNIT LENGTH.
Taking down carefully ceiling fan and keeping the safe custody for reuse at site after completion of building repair work including painting of ceiling fans with one coat of synthetic enamel paint by spray painting process including filling cavities with filler, after cleaning all dust and the like complete all as specified and directed.
Taking down carefully exhaust fan of any sweep and description and keeping the safe custody for reuse at site after completion of building repair work including refixing of the same on existing place after cleaning including necessary fixing arrangement as required at site and making electric connection complete all as specified and directed.
S & F of MCB single pole and neutral, 240 volts, 32 to 40 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of MCB single pole, 240 volts, 6 to 32 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of MCB triple pole and neutral, 415 volts, 40 Ampere breaking capacity 10 KA, ‘B’ Series complete all as specified and directed.
S & F of flush mounting factory made SPN DB's Double door, 8 way, IP-42 Protection, detachable gland plates for MCB fitted with bus bar, earth bar and neutral links with and including taking down old unserviceable one complete all as specified and directed.
S & F of flush mounting factory made TPN DB's Double door, 4 way, IP-42 Protection, detachable gland plates for MCB fitted with bus bar, earth bar and neutral links with and including taking down old unserviceable one complete all as specified and directed.
Taking out old unserviceable earthing any type and M & L for earthing complete with galvanised steel earth plate electrode 600 mm X 600 mm X 6 mm thick buried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.50 m below normal ground level, connected to galvanised earth lead 4 mm dia all as shown on electrical plate No. 3 of MES schedule 2009, Part–I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1, duly reinforced with 6 mm dia mild steel TMT bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:2:4 type B-1, GI protection pipe light grade 15 mm bore including testing on completion of job complete all as specified and directed.
Supply and laying XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with stranded aluminium conductor 1100 volt grade, laid in trenches/ducts, fixed on wall/inside panel, drawn through pipe of cross sectional area 10 Sqmm 4 core with and including taking out old unserviceable one complete all as specified and directed.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after laying of cable in trenches, punning complete all as specified and directed. Note:- Punning thickness of 18 cm will be considered for payment.
M & L for laying brick as in protection covers over cables using sub class 'B' old size bricks laid flat, length wise perpendicular to the axis of cable complete all as specified and directed.
S & F in replacement 40 mm bore GI pipe light grade for cable protection, fixed to pole/ alongwall/ floor/ under road/ across the drain or nallaha etc complete all as specified and directed.
NOTE:- Tenderers may note that amount of credit Rs 65,800.00 will be deducted from the total amount arrived at the time of Acceptance of tender.
M/S Shree Sai Builders
JAI SRI RAM ASSOCIATE
RIYASAT ALI KHAN
hardeep singh enterprises
M/S Harshri Nath Enterprises
Jain construction co
M/S YASHCON CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .