Executive Engineer (E)
O/o Executive Engineer (Electrical) BSNL, Electrical Division 1st Floor, Telephone Exchange Laxmi Road, Dehradun
Rate Contract for Providing Call basis Servicing and repairing of ACs units of various exchanges BTSs in BA Haridwar
2024_BSNL_192122_1
74/EE/BSNL/ED/DDN/23-24
Open Tender
Electrical Works
Item Rate
180 days
Haridwar
Please refer tender documnets
4 documents required · 4 mandatory
₹590
Accounts Officer (Cash), O/o GMTD, BSNL, Haridwar
₹7,318
10 Apr 2024
21 Mar 2024
1 Apr 2024
21 Mar 2024
30 Mar 2024
21 Mar 2024
Amount
Visit charges to attend the fault of AC unit on call /Complaint basis at Exchanges/ BTSs i/c analysis of fault, minor repiring , and making the detailed list of defects and estiimation of the same i/c to & fro transportation chargesetc. complete as required.
In OA Haridwar i/c Roorkee area City area
In OA Haridwar i/c Roorkee area Rural area
In OA Srinagar area
General Servicing of all type & capacity WAC /SAC /HSHF /Water cooler units at site of different make and model I/c removing from existing position if reqd, dismantling of faulty parts, cleaning the air filter, cleaning the condenser and evaporator coil with help of water pressure spray gun , lubrication of moving parts, complete checking, testing and minor faults rectification i/c replacement of knobs/ wiring kit (if required), setting of thermostat, preparing report including tightness of all electrical connections from SP MCB in DB to DP MCB/Plug & socket to stablizer to AC unit etc as reqd.
In OA Haridwar i/c Roorkee area City area
In OA Haridwar i/c Roorkee area Rural area
In OA Srinagar area
Charging of Refrigerant gas R-22 /R-32/410 up to specified pressure(as per manufacturer's recommendation) in following capacity AC units and pressure testing by nitrogen, vaccumisation for 2 hours, purging with gas and testing commissioning of the AC unit etc. as reqd. Note: One job consists of charging of Gas in one compressor i.e.. One complete air conditioning circuit only.
Replacement of the following items/accessories in the existing WAC/SP AC/water cooler Units of all makes in place of faulty/unserviceable parts i/c dismantling of the faulty, fixing the new item and testing, connection etc. complete as reqd.
120-140 MFD Starting Capacitor aluminum case
40/50 MFD Running Capacitor aluminum case
4MFD Fan Motor Capacitor aluminum case
WAC Blower /WAC/condenser fan blade
Starting relay
PCB for Split AC 1.5 TR/2TR
PCB for inverter type Split AC Indoor Unit
PCB for inverter type Split AC 1.5 TR-For Out door Unit
Contactor coil 230 V AC
Time delay relay unit for outdoor unit
S/F of Blower/Condenser fan motor for 1.5 / 2 TR Window/Split A.C/water cooler unit in lieu of unservisible motor i/c connection etc as required.
Provision of Top up of R-22/R-32 /410 gas in existing all type Window A.C /Split A.C/ units, flushing, testing etc. as required.
Rewinding of existing all type Blower/condenser fan motor for 1.5/2 TR Window/Split A.C unit/water cooler i/c replacement of bush i/c oiling ,greasng etc as required
P/F 12mm thick Exterior grade particle board for AC Unit for support i/c fixing the same with screw ,complete etc. as reqd.
Replacement of the 1.5 TR rotary type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required. Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
Replacement of the 1.5 TR Reciprocating type compressor I/c dismantling of the existing compressor from site, to and fro transportation charges and I/T/C of compressor in existing WAC / Split AC etc complete as required. Note: The agency has to provide one year guarantee for every replaced compressor along with Test Certificate / Invoice of Purchase from authorized dealer, Faulty Compressor shall be the property of contractor.
Replacement of following faulty accessories in exsiting DB , connections, testing etc comp as reqd.(Make--Legrand or similar superior make)
5 A to 32 A , 240/415 V, 10 kA, "C" curve, SP MCB
5 A to 32 A , 240/415 V, 10 kA, "C" curve, TP MCB
15 A Plug Top
S/F of DP Sheet Steel enclosure on surface /recess with 25 A , 240V " C" Curve DP MCB Complete with connectionn ,testing ,comissioning etc as reqd
Replacement of following faulty accessories in exsiting Timer/ controllor unit , connections, testing etc comp as reqd.(Make--Legrand or similar superior make)
2 Pole Contactor 25 A ,230V (Make-L&T- 25 A-MNX)
Supplying & fixing Analog daily time switch of 16 A Capacity ,One C/O ,Din /Base mounting , 24 hour Programmable operation for Used for Automatic switching ON/OFF for Electric street lights suitable to work on 230 V AC Supply i/c connection etc Timer - (Make-L&T /GIC or similar superior make)
Installation, Testing & Commissioning of the following type Split type AC unit at a specified location as per direction of Engg-In-charge by mounting/fitting Indoor and Outdoor units , making opening in wall behind indoor unit , laying and fixing of both liquid and hot gas lines , inter connecting wiring for both indoor outdoor units up to 3 mtrs length and ,interconnecting the indoor unit and outdoor unit with refrigerant line, insulating the refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle , Leak testing entire system ,vacuemising the system ,charging of Refrigerant gas in the unit ,making power supply connections from the power point,and making good the damages etc.as required.
1.5/2 TR Split AC unit
2x1.5/2 TR HSHF AC unit
Pdg and Fixing of following size additional following size same as supplied by Split AC manufacturer refrigerant copper piping with 3x2.5 sq.mm. PVC Insulated PVC Sheathed copper cable i/c covering of Copper Pipe with polystyrene insulation i/c cutting ,brazing ,jointing,bends, sockets etc as reqd. ( Note- Combined Length shall be measured )
S/F of 50 mm dia PVC pipe for wall crossing of refrigerant and drain pipe of split AC units etc as reqd.
S/F of 19 mm dia PVC Wire braded pipe for drain water of SPAC i/c fixing on wall surface with suitable MS shaddle etc.as te reqd.
S/F Powder coated MS stand, for wall /Floor mounting of outdoor unit of Split AC i/c fixin gthe same on wall with suitable fastner etc as reqd
Supplying and fixing of following size of white colour flexible copper cable on surface/ recess, suitable for work on 230 volt, 50 HZ AC supply i/c connection etc as reqd (Note--Cables have joints shall be replaced to avoid fire hazard)
3x1.5 sq mm
3x2.5 sq mm
Insulating the existing laid refrigerant pipe with expandable polyethylene Foam tubing unit and fixing with suitable MS shaddle etc as reqd
Dismantling of the existing split /window type AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to a safe place in exchange premises and handing over to the incharge,packing of SPAC wall hole ,making good the damage etc as reqd .
Dismantling of the existing 2x1.5/2 TR HSHF type Split AC Unit complete with indoor unit,outdoor unit stand, refrigerant piping,drain pipe,shifting the dismaltled items to other room in same exchange premises ,packing of SPAC wall hole ,making good the damage etc as reqd .
Closing of existing window in AC opening area to prevent AC leakage/theft by Single brick masnoary i/c plastering with cement mortar , finishing etc complete as reqd as reqd.
Transportation of Split /Window AC units/water cooler with all acessories like indoor ,outdoor unit ,copper pipe ,drain pipe ,partical board ,stand from One TE building to various TE /BTS sites in BA Dehradun i/c. loading,unloading etc. as reqd.
Supplying & fixing of powder coated Free Cooling unit made out of 18 gauge M.S.Sheet box with locking door in front & jali in back side i/c Supplying & fixing 300 mm sweep Heavy Duty Exhaust Fan 1400 rpm suitable for 230 V 50 HZ AC Supply i/c making opening in brick wall / window for fixing of unit, connection , testing etc (Exhaust Fan Make-- Crompton / Havells/ Bajaj or similar superior make )
Out door unit ( For exhaust of hot Air)
S/f timer unit constituting of 01 no. digital type thermostat/ Temp controller with LED display & sensor with lead and 01 no. Analog Time Switch /Electronic timer (1 second to 10 hrs ) in suitable size MS box with hinged door, connection etc. as required. (Timer Make-BCH/L&T/GIC-J648B1 & Analog Time Switch make - SELEC - TC513/TC533BX or similar superior make) Note-- Timer will run Exhaust fan for 2 hrs and kept in off position for 15 minutes
JAI SAI ENGINEERING
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .