Tender Value
Refer Docs
EMD Value
₹52,000
Closing Date
9 Oct 2021, 6:00 pmClosed
GE I CG PORBANDAR
MILTARY ENGINEERING SERVICES, DHQ-01 GE I CG PORBANDAR OPP BIRLA FACTORY PORBANDAR
COMPREHENSIVE REPAIR AND MAINT OF COOLING APPLIANCES, RO PLANTS AND DOSING PUMP AT HQ ICGS UDHYOG BHAVAN, LEKAWADA AND VARIOUS SECTORS OF GANDHINAGAR UNDER GE I CG PORBANDAR
2021_MES_474624_1
8644
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
ICGS GANDHINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE I CG PORBANDAR
₹52,000
Yes
21 Dec 2021
13 Sept 2021
11 Oct 2021
13 Sept 2021
9 Oct 2021
27 Sept 2021
Amount
SCHEDULE 'A'
M&L for taking down of ACs of split type capacity 1.5/ 2.0 TR from the existing site and taking out filter and servicing the complete in all respact and fixing the same in origanal location, and testing complete all as specified and as directed. Note:- Contractor has to provide blower and jet pump for cleaning and washing of AC, A separate PVC bag will also be provided for collection of waste, mechanic will be responsible to clean the site after servicing.
M&L for dismantaling and shifting the existing split Acs of cap 1.5/ 2.0 ton to new location complete all as specified and as directed. Note:- Copper pipe will be measured and paid separately under relevant items.
S&F in repair foam armoar of size 5/ 8" for AC copper tybing complete all as specified and as directed. Make:- Superlon or equivalent make as approved by GE.
S&F in repairs foam armoar of size 1/ 4" for AC copper tybing complete all as specified and as directed. Make:- Superlon or equivalent make as approved by GE.
S&F in repairs compressor suitable for existing window type AC 1.5 TR.
S&F in repairs compressor suitable for existing split type AC 1.5 TR.
S&F in repairs compressor suitable for existing split type AC 2 TR.
S&F in repairs condenser suitable for existing window type AC 1/1.5 TR.
S&F in repairs condenser suitable for existing split type AC 1.5 TR.
S&F in repairs condenser suitable for existing split type AC 2 TR.
Installation only air conditioner of cap 1.5/ 2.0 ton split type including supply and fix MS powder coated brackets complete all as specified and as directed. Note:- (a) AC 1.5 TR split type and available length copper pipe will be issued under schedule 'B' free for fixing. (b) Extra copper pipe, if required will be measured and paid separately.
M&L in repairs for sub main wiring complete in repair with PVC insulated FR cable of single core 4.0 sq mm 660/1100 volts geade with multi stranded copper conductor drawn through steel/ PVC conduit concealed or surface/ ceiling and 4.0 sq mm unsheathed multi stranded copper conductor as earth wire in green colour complete all as specified and as directed. Note:- Two runs of cable and one run of earth wire and conduit shall be measured as one unit length.
M&L for rewinding only to blower motor for 1.5 TR split/ window AC complete all as specified and as directed.
S&F in repairs starting capacitor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repairs starting capacitor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repairs starting capacitor suitable for existing window AC of cap 1.0/1.5 TR complete all as specified and as directed.
S&F in repairs running capacitor suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repairs running capacitor suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F repairs running capacitor suitable for existing window AC of cap 1.0/1.5 TR complete all as specified and as directed.
S&F in repairs starting relay suitable for existing split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repairs starting relay suitable for existing split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repairs starting relay suitable for existing window AC of cap 1.0 TR complete all as specified and as directed.
S&F in repairs circuit plate with PCB for 1.5/ 1.0 TR window type AC.
S&F in repairs condenser fan blade suitable for split AC 1.5 TR complete all as specified and as directed.
S&F in repairs condenser fan blade suitable for split AC 2.0 TR complete all as specified and as directed.
S&F in repairs fan blade (evoparator) suitable for split AC of cap 1.5 TR complete all as specified and as directed.
S&F in repairs fan blade (evoparator) suitable for split AC of cap 2.0 TR complete all as specified and as directed.
S&F in repairs circuit plate with PCB suitable for split AC of cap 1.5 TR.
S&F in repairs circuit plate with PCB suitable for inverter type of indoor/ outdoor AC suitable for split AC of cap 1.5 TR.
S&F in repairs circuit plate with PCB suitable for split AC of cap 2.0 TR.
S&F in repairs circuit plate with PCB inverter type of indoor/ outdoor AC suitable for split AC of cap 2.0 TR.
S&F in repairs PVC air filter suitable for existing split AC of cap 1.5 TR.
S&F in repairs PVC air filter suitable for existing split AC of cap 2.0 TR.
S&F in repairs remote controller suitable for existing split AC of cap 1.5 TR.
S&F in repairs remote controller suitable for existing split AC of cap 2.0 TR.
S&F in repairs cooling coil motor suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs cooling coil motor suitable for inverter type AC of cap 1.5/ 2.0 TR.
S&F in repairs swing motor suitable for existing split AC of cap 1.5 TR.
S&F in repairs swing motor suitable for existing split AC of cap 2.0 TR.
S&F in repairs condenser motor suitable for existing split AC of cap 1.5 TR.
S&F in repairs condenser motor suitable for existing split AC of cap 2.0 TR.
S&F in repairs condenser motor suitable for existing split AC inverter type of cap 1.5/ 2.0 TR.
S&F in repairs line reactor suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs contactor relay suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs contact sensor (indoor/ outdoor/ gas pipe/ temp) suitable for existing split AC inverter type or non inverter type of cap 1.5/ 2.0 TR.
S&F in repairs copper tube of 16 Sqmm bore.
S&F in repairs copper tube of 12.7 Sqmm bore.
S&F in repairs copper tube of 9.5 Sqmm bore.
S&F in repairs copper tube of 6.3 Sqmm bore.
S&F in repairs drain pipe PVC, suitable for split AC of cap 1.5 TR.
S&F in repairs bracket suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs brass valve 1/4" suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs brass valve 1/2" suitable for existing split AC of cap 1.5/ 2.0 TR.
S&F in repairs brass valve 5/8" suitable for existing split AC of cap 1.5/ 2.0 TR.
Supply and filling gas freon (R22) or suitable for existing system. Note:- (i) Gas bottle to be arranged by contractor. (ii) Labour charges deemed to be included in quoted rate.
S&F in repairs acrylic vegetable tray suitable for existing refrigerator of cap 165 to 310 ltr.
S&F in repairs relay with over load protector suitable for existing refrigerator of cap 165 to 310 ltr. Make:- AEI/ Shriram or equivalent make as approved by GE.
S&F in repairs to body/ base of water cooler 40/ 80 ltr cap, by replacing the rusted portion with PGI sheet to match with existing body with and including preparation of surface to smooth finish and duly painted complete with two coats of synthetic enamel paint complete all as specified and as directed.
All as per Item No. 58 here in before but cap 200 to 215 ltr refrigerator.
All as per Item No. 58 here in before but cap 300 to 310 ltr refrigerator.
All as per Item No. 58 here in before but desert cooler.
M&L for praperation of exterior portion of water cooler 40/ 80 ltr cap to a smooth finish and applying two coats of synthetic enamel paint complete all as specified and as directed.
Supply and filling refrigerant gas freon R-34/ R-22/ R-143a or as recommended by manufacturer complete all as specified and as directed. Note:- (i) Gas bottle to be arranged by contractor without any extra cost. (ii) Labour charges deemed included in the quoted rate.
M&L for taking out desert cooler of any size and capacity from existing site for repair and dismentaling of all components from evoparative cooler (desert cooler) metal body very care fully i.e. exhaust fan, motor, tulu pump, PVC spare parts i.e distributor, PVC pipe, tee, bend, elbow, holding clamp and any number of nut, bolt, washer, grass paid etc, including praparation of exterior and interior portion on cooler to a smooth finish and applying one coats of bituminious paint and reaasembling the same in existisng position in cooler for smooth running complete all as specified and as directed. Note:- If any worn out items/ parts found during the assembling the same shall be measured and paid separately under the relavent items of schedule.
S&F in repairs starting relay suitable for existing refrigerators/ water cooler.
S&F in repairs over load protection suitable for existing refrigerator/ water cooler of cap 300 to 320 ltr.
S&F in repairs fan motor suitablr for existing water cooler 80 to 120 ltr cap.
S&F in repairs brass chromium plate push cock of 15mm dia.
S&F in repairs cabin bulb 5 watt for refrigerator.
S&F in repairs cabin bulb holder for refrigerator with cabin brackets.
S&F in repairs thermostate switch for water cooler 40/ 80 to 120 ltr cap.
S&F in repairs fan motor suitable for refrigerator 190 to 280 ltr cap.
S&F in repairs fan motor suitable for refrigerator 300 to 310 ltr cap.
S&F in repairs timer suitable for refrigerator of 100 ltr to 280 ltr cap.
S&F in repairs condenser suitable for existing water cooler/ refrigerator.
S&F in repairs compressor suitable for existing water cooler of cap 40/ 80 ltr.
S&F in repairs compressor suitable for existing refrigerator of cap 280 ltr.
S&F in repairs fan blade for desert cooler.
S&F in repairs PVC connection set of three suitable for existing desert cooler.
S&F in repairs cable three core flexible twiested copper conductor of 1.5 Sqmm.
S&F in repairs cable three core flexible twisted copper conductor of 2.5 Sqmm.
S&F in repairs front grill suitable for existing desert cooler.
S&F in repairs grass paid set of three superior quality.
S&F in repairs motor 1.0 Ph, 50 HZ 230 V, AC max Amp 1.5, suitable for existing desert cooler.
S&F in repairs tillu pump/ water pump for deseart cooler 240 V, AC 50 HZ, 10 Watt, 5 LPM, 2.0 mtr head.
S&F in repairs capacitor 4 Mfd + 5% 440 V MPP 'SH'
S&F in repairs capacitor 2.5 Mfd + 5% 440 V MPP 'SH'.
S&F in repairs capacitor 6 Mfd + 5% 440 V MPP 'SH'.
Comprehensive maintenance and servicing of air conditioner of model DSA1021R1 ductable type comprising of hermetic/ semi harmetically scrolled compressor indoor/out door unit with refrigerant use R--22/ R-407 C R 410a, of capacity 8.75 TR, making servicing of the plants and making fully in serviceable condition installed at ICGS Udhyog bhawan complete all as specified and as directed. Make:- Blue Star Note:- (i) The rates quoted by the tenderer includes the cost of complete comprehensive service including replacement of spares as required and visit the site at interval of 90 days to verify functioning of AC units till completion of contract as mentioned in Work Order No. 1. (ii) Rates inclusive of replacement of parts during currrency of contract as and when directed by Engr-in-Charge. (iii) Servicing/ Repairs of AC units shall be carried out through the OEM only. (iv) Contractor has to submit test certificate on completion of service/ repairs of AC units issued by service provider. (v) contractor is responsible to proper functioning of AC, leakage and seapage repiare is sole responsibility of contracter quoted rates should incl leakage and seapage repaire. (vi) this is Type 'A' AMC i.e. ALL IN ALL so that spares required will be provided by the contracter with in stipulated time period. (vii) complaints should be attended and rectified in 24 hr otherwise a penalty of rupees 2000.00 Rs per day will be recoverd from the contractor.
M&L for taking down outdoor unit of split AC of cap 1.5/ 2.0 TR from site, opening the same and segregate serviceable parts if exist, for reuse, and replacement of parts like capillary valve, outdoor sheet, legs, top cover with stand as per existing make at site and fixing the same at site including testing complete as directed by Engr-in-Charge.
M&L for taking down of indoor unit of split AC of cap 1.5/ 2.0 TR from the wall, opening the same and segregate serviceable parts if exist, for reuse and replacement of parts like cooling coil, motor, outer body with hanging plate with complete nuts and bolts as per existing make at site and fixing the same at site including testing complete as directed by Engr-in-Charge.
S&F in repairs gas filter and NRV suitable for existing refrigerator and water cooler of cap 40-280 ltr.
S&F in repairs drain pipe for water cooler.
S&F non adhesive tape roll for copper tubing of AC.
S&F in repairs fan blower suitable for existing split AC.
Comprehensive maintenance/ servicing and testing of RO plant including washing, cleaning of sedimentation filter, disinfection process, servicing of pressure pumping set and dosing unit complete at so as to supply qualitative water at permissible level of TDS. Note:- (a) Spares required for replacement will measured and paid separately under respective items here-in-this schedule. (b) The rate quoted by the tenderer includes cost of maint/ servicing of above said plant once in a period of 90 days till the date of completion of work. (c) Servicing should be done by OEM/ authorized agency and not by any local mechanic. (d) Contractor shall be produce all purchase voucher and test certificate before submitted RAR. (a) RO plant 60 ltrs capacity at Coast Guard Udyog Bhawan and Single Living Accn.
(b) RO plant 50 ltrs capacity at Coast Guard Udyog Bhawan.
(c) RO Plant 25 Ltrs capacity at Coast Guard.
(d) RO Plant 25 Ltrs capacity at Coast Guard Lekhawada. Note:- Servicing should be done by OEM/ authorized agency and not by any local mechanic.
S&F in repairs sediment filter as exiting for 60 Ltr RO plants.
S&F in repairs sediment filter as existing for 25/50 ltr RO plants.
S&F in repairs RO membrane as existing for 50 Ltrs RO plant.
S&F in repairs RO membrane for as existing 60 Ltrs hydramem 4021, RO plant.
S&F in repairs RO membrane 80 GPD as existing 25 Ltrs RO plant.
S&F in repairs RO membrane Housing as existing 50/ to 25 Ltrs RO plant.
S&F in repairs carbon filter for 25/ 50 Ltrs RO plant.
S&F in repairs carbon filter for 60 Ltrs RO plant 20".
S&F in repairs spum filter for 50/ 60 Ltrs RO plant.
S&F in repairs PF candle for 50/ 60 Ltrs RO plant.
S&F in repairs cartridge filter 20" of 60 ltr RO.
S&F in repairs membrane housing for 60 ltr RO plant.
S&F in repairs control module of 60 ltr RO plant.
S&F in repairs low/ high pressure switch of 60 ltr RO plant.
S&F in repairs centrifugal pump for 60 ltr RO plant.
S&F in repairs 1/2 Pipe for 60 Ltrs RO plant.
S&F in repairs solenoid valve of 230 Volt for 60 ltr RO plant.
S&F in repairs raw water pump for 60 ltr RO plant.
S&F in repairs filter housing for 60 ltr RO plant.
S&F in repairs dosing pump for 60 ltr RO plant.
S&F in repairs dosing drum for 60 ltr RO plant.
S&F in repairs water controler sensor for 60 ltr RO plant.
S&F in repairs UV system for 60 ltr RO plant.
S&F in repairs UV lamp for 60 ltr RO plant.
S&F in repairs connectors for 60 ltr RO plant.
S&F in repairs chassis for 60 ltr RO plant.
S&F in repairs 1/4 Pipe for 25/ 50 Ltrs RO plant.
S&F in repairs low pressure/ High pressure DC switch for 25/ 50 RO plant.
S&F in repairs stainer for 25/ 50 Ltrs RO plant.
S&F in repairs stainer for 60 Ltrs RO plant.
S&F in repairs anti scalant chemical.
S&F in repairs chloroscope (range-0.1 ppm to 2.0 ppm).
Supply and fix solenoid valve for 25/ 50 ltrs RO plant.
S&F in repairs booster pump 48 VDC suitable for 50/ 60 Ltrs RO plant.
S&F in repairs pump 36 V, DC suitable for 25 Ltrs RO plant.
S&F in repairs control module for 25/ 50 ltrs RO plant.
Comprehensive maintenance and servicing of RO 8/ 10 Ltr capacity in a period of 4 months to make the purifier working to satisfactory conditions. Locations:- HQ SWAC - 01 No. and Duty Crew Room COMN FLT - 01 No, CEGO Br - 01, MI Room Sec 13 - 01. Note:- (i) Service should be done by OEM/ authorized agency only.
S&F in repairs UF cartridges for 8/ 10 Ltrs RO as existing at site or directed by Engg-in-Charge.
S&F in repairs sediment filter for 8/ 10 Ltr as existing at site or directed by Engg-in-Charge.
S&F in repairs carbon filter for 8/10 Ltr RO as existing at site or directed by Engg-in-Charge.
S&F in repairs pump for 8/ 10 Ltr RO as existing at site or directed by Engg-in-Charge.
S&F in repairs membrane 75 GPD for 8/ 10 RO as existing at site or directed by Engg-in-Charge.
S&F in repairs solenoid valve for 8/ 10 Ltr RO as existing at site or directed by Engg-in-Charge.
S&F in repairs float cut off valve for 8/ 10 Ltr RO as existing at site or directed by Engg-in-Charge.
S&F in repairs auto level sensor as existing at site or directed by Engg-in-Charge.
S&F in repairs anti chlorine candle as existing at site or directed by Engg-in-Charge.
S&F in repairs anti scalent balls as existing at site or directed by Engg-in-Charge.
S&F in repair FR switch suitable for existing RO plant as directed by Engg-in-Charge.
Dismantling, cleaning and overhauling of 0.25 HP centrifugal mono block pump set/ pressure booster pump set of the following capacities including rewinding of motor with appropriate super enameled copper wire of existing gauge, replacement of bearing - 02 Nos, including all connection and testing complete for following capacities:- (i) Replacement of bush (gland). (ii) Replacement of pump shaft. (iii) Replacement of impeller. (iv) Replacement of shaft sleeve. Note:- Suitable for RO plant Monoblock pump only.
All as per Item No. 148.00 above, but 0.5 HP capacity pump complete.
M&L for making of stand suitable as existing RO plant of cap 25 to 50 ltr, incl provn for fixing at wall or as per site requirement, complete necessary plambing and other works, and as directed by Engr-in-Charge.
M&L in repairs/ replacement of Digital LCD TDS meter tester water quality 0-1999 ppm PH test set filter purity mode with resolution 1 PPM. Make:- Noctronique model No. CB45154 or equivalent make as approved by GE.
M&L in replacement of pressure booster pump with pressure controller for constant water pressure of capacity 1/ 0.75 HP CM pump is supplied with pressure tank, include pre set leval, pump operate as set level complete including fixing the same with all materials which is required at site, and as directed by Engr-in-Charge. Note:- Mechanic will collect complaint from Eng-in-charge/ JE E/M from any mode, complaints of cooling appliances (AC, Ref, Water Cooler, Deep Freezer) and RO should be attended and rectified within 24 Hr otherwise a penalty of Rs. 2000.00 per day per complaint will be recoverd from the contracter.
DIGNATION ENTERPRISE
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .