Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹47.4 L+₹1.5 L (3.30%)Rejected-AOC OPP KIRYAPA PARK NATIONAL HIGHWAY ROAD BARAMULLA J K 193101 | NA | NA | 193101 | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹48.9 L+₹3.0 L (6.53%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹49.0 L+₹3.1 L (6.67%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest | |
| 5 | L5₹51.1 L+₹5.2 L (11.4%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹49.5 L
EMD Value
₹98,900
Closing Date
13 Jan 2024, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
REPAIR MAINT OF ELECTRIC SUPPLY WITH ALLIED INFRA AND REPAIR MAINT OF INTERNAL WIRING AT VARIOUS LOCS UNDER GE 969 EWS
2023_MES_632955_1
CA NO 969 WS - /2023-24
Open Tender
Civil Works
Item Rate
180 days
GE 969 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹98,900
Yes
27 Jan 2024
15 Dec 2023
15 Jan 2024
15 Dec 2023
13 Jan 2024
1 Jan 2024
Amount
Disconnecting HT/LT cable and earthing connections of burnt/defective transformer of capacity 50 KVA to 200 KVA, 11 KV/433 volts 3 phase from pole/floor mounted, taking from site of installation carefully with the help of Crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair. replacement of complete gasket set, refilling the oil duly filtered / dehydrated, topping up with new oil, carrying out routine tests, including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specifed & as directed. Note :- New transformer oil and Dehydration of Transformer oil shall be measured and paid separately.
M&L for Hiring, transportation, installation and testing of serviceable transformer of existing capacity on hired basis in place of unserviceable transformer which is under repair and shifting back to workshop on hire basis for 15 days when ordered complete all as specified and directed by engr in charge. Note:- (1) Repairing of transformer shall not exceed beyond 15 days from the date of dismantling from original site, (2) Contractor shall not be allowed to shift hired transformer untill it is replaced by orginal one. (3) Hired transformer will match with the existing transformer with same voltage, vector group, impendence etc. (4) Incase the defective/unservicable transformer is not repaired with in stipulated period of 15 days a penalty of Rs 1000/- per day will be deducted and no extra cost willl be paid to the contractor un less natural calamidity is occured.
Material & labour for rewinding of LT side winding with copper strip/wire of suitable size/gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and as directed.
Material & labour for rewinding of high tension with supreme enamelled copper wire of suitable size/gauge, fixing the coil in position in core assembly and making connection as per existing pattern including providing insulation, varnish etc complete all as specified and as directed.
Disconnecting HT/LT cable/busbar and Earthing connections complete of transformer capacity up to 63 KVA, 11 KV/433 Volts 3 phase from pole/ floor/transformer shed with the help of Crane to carry out complete maint of transformer comprising of the following:- (i) Draining out oil from chamber. (ii) Opening top cover, disconnecting winding connection from bushings and taking out carefully core assembly complete with winding. (iii) Checking compactness of core & tightening the same where required. (iv) Chemical washing of winding to remove dirt,dust & carbon particles (v) Cleaning of oil tank to remove oil sludge followed by painting of inner surface of tank with zinc chromate base paint (vi) Refixing of core & winding assembly and making connection with HT/LT bushing . (vii Replacement of worn out gaskets & nut/bolts. (vii) Refilling of oil duty filtered/dehydrated/fresh oil (to be measured & paid separately under respective item) (Note: Overhauling of transformer should be done on existing installation place on same days)
Al as per item No. 5 above but transformer capacity from 100 KVA to 200 KVA.
Al as per item No. 5 above but 100 KVA to 200 KVA. (Indoor/outdoor type)
Supply and pouring new transformer oil as as per IS: 335 (1993) for transformers installed at various site well as transformers under repair for topping up after dehydration to achieve the di electric strength 60 KV at 4 mm gap, complete all as specified and as directed. Note: Transformer oil shall be brought at site in sealed container from the original manufacturer and shall be opened in front of Engr-in-charge Supply and pouring new transformer oil as per lS:335 (1993) for transformers installed at various site for topping up after dehydration to achieve the di electric strength upto 60 KV at 4mm air gap compiete all as specified and as directed.
Material and Labour for heating. filtration and dehydration of transformer oil as per IS: 10028 (Part-llI) 1981, Para 5.2 with dehydration/ filtration plant to achieve dielectric strength of 60KV at 4 mm air gap, complete all as specified and as directed.
Testing of transformer oil as per IS: 335 and IS 12463 for dielectric strength of transformer installed in various Site, plinth mounted/pole mounted including submission of test report complete all as specified and as directed.
S&Fing in replacement of silica gel breather assembly with vent pipe complete with fresh blue coloured, for transformer of capacity 50 KVA to 200 KVA complete all as specified and as directed.
S&Fing in replacement LT bush assembly brass complete with brass spindle, nuts, bolts, washers etc with bushing insulators suitable for transformer of capacity 50 KVA to 63 KVA complete all as specified & as directed.
All as per item No.12 above but transformer capacity from 100 KVA to 400 KVA.
S&F in replacement 11KV porcelain bushing insulators for HT side of out door/indoor type transformer.
Excavation in trenches n exc 1.5 m wide & n exc 1.5 mtr deep in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes not exc 10 sqm on plan and n exc 1.5 mtr in depth and getting out in soft/loose soil for taking out pipe & laying of pipe and getting out for diverting of CI pipe line, complete all as specified and as directed.
Removing of excavated soil not exceeding 50 M and depositing where directed at a level not exc 1.5 M above the starting point complete all as specified and as directed.
Returning filling in incl spreading leveling, watering and well ramming in layers not exc 25 cm complete all as specified.
M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified and as directed.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in trenchs as cable protection complete all as specified and as directed.
Supply & laying of UG cable LT 1100 volts grade XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor cross section area 95 Sqmm 3.5 core laid in trenches or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed.
All as per item No 20 here in before but of size 70 Sqmm 3.5 Core
All as per item No 20 here in before but of size 35 Sqmm 3.5 Core
All as per item No 20 here in before but of size 25 Sqmm 3.5 Core
All as per item No 20 here in before but of size 16 Sqmm 2 Core
All as per item No 20 here in before but of size 10 Sqmm 2 Core
Supply and laying or fixing or passing through pipe in repairs, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed stranded conductor of size 10 sqmm nominal cross section twin core in service connections including taking down.
S&F in replacement of MCCB 415V olt 16 KA, 4 Pole 63 Amps Capacity complete including taking down old unserviceable MCCBs complete all as specified and as directed.
All as per item No. 27 herein before but 100A, 25KA
All as per item No. 27 herein before but 125A, 35KA
All as per item No. 27 herein before but 160A, 36KA
All as per item No. 27 herein before but 200A, 36KA
All as per item No.27 herein before but 250A.36KA
All as per item No.27 herein before but 400A,36KA
S&F on load changeover switch Range 100A, 415V, 4P, confirming to IEC 60947-3, IS/IEC 60947-3 Conforms to Staggered terminals, Site convertible fuse version for open execution Flip able handle above 400A Interchangeable dual shaft position with site convertibility along with SS enclosure version require separate cable gland boX complete all as specified and as directed.
All as per item No. 34 here in before but of capacity 200 Amp
M&L PVC spacer suitable for 2/3/4 wire LT OH line inciuding taking down of old one
Supply and laying Gl pipe 50 mm bore light grade witn fitting for cable protection at road crossing/ under concrete including taking down of old one.
S&F in repair ACSR conductor of (weasel) 6/1 X 2 59mm, streching properly on insulators and binding with aluminium binding wires, jumpers including fxing on insulators on each poles in span and tightening with permissible sag in between span etc complete all as specified and as directed by Engineer-in-charge (Including dismantling and taking down)
S&F in replacement of lugs or thimbles suitable for 25 Sqmm to 70 sqmm aluminum coductor cable
S&F in replacement of lugs or thimbles suitable for 95 Sqmm to 185 sqmm aluminum coductor cable.
Dismantling /disconnecting & taking down insulaters of any size & capacity.
M&L for Pin type Porcelain, vitreous, white brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 50mm height, 100 mm dia for 1100 volts grade.
S&F Pin type, porcelain, vitreous, brown insulator including one galvanised mild steel spindle, two galvanised washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade HT over head line. complete all as specified and as directed.
Earthing complete with GI earth plate electrode 600cmX600cmX3.15mm thick, ground burried directly in Ea (earth pit not less than 2.25 metres deep below ground evel)with top edge of the plate not less |than 1.5 metres below normal groundlevel, connected to G! strip earth lead strip 32x6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of| SSR Part-l connected to earthing test point all as specified or indicated including excavation and Connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC) 1:2:4 type B-1 cOver slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion all as specified and directed. Note- Rate quoted deemed to be include excavation and earth work in any type of soil with PCC type B2 in pit POCC Cover & other arrangement Complete all as specified and as directed.
Taking down carefully any type point wiring (light, fan, socket or power) complete including concealed conduits/casing- capping with fittings such as light fittings, sockets, switches ceiling roses, board outlets etc and removing the materials/ debris and making good the disturbed surfaces of walls, floor etc to match with the existing surface.
M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 20 mm medium grade ISI marked conduit conceled in wall/ceiling all accessories such as bends, elbow, reducers, junction boxes /MS boxes duly painted /PVC box factory made rectangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following : Note: Contractor must do internal wiring with cheasel cutting in wall/ceiling and fixed conduit and repair surface with plaster 15MM in wall/ceiling and make surface good as it is.
(a) Description all as item no.46 above but for One light/ceiling fan point controlled by one switch.
(b) Description all as item no.46 above but for One switch socket combination 5 Amps on independent board
(c) Description all as item no.46 above but for One switch socket outlet 5 Amps on same board with other switches.
M&L Point wiring complete with FRLS 1100 Volts grade, 2.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 20 mm medium grade ISl marked conduit concealed in wall/ceiling all accessories such as bends, elbow, reducers, junction boxes /MS boxes duly painted /PVC box factory made rectangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 2.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following : Note: Contractor must do internal wiring with cheasel cutting in wall/ceiling and fixed conduit and repair surface with plaster 15MM in wall/ceiling and make surface good as it is.
M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISl marked PVC casing caping with all accessories such as bends, elbow, reducers, junction boxes /MS boxes duly painted /PVC box factory made rectangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixed with screws, for housing switches, sockets, regulators etc, including 1.5 sqmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed, for the following :
(a) One light point/fan point/Exhaust fan point controlled by one 5 Amps switch one way
(b)One 3 pin 5 Amp switch socket outlet on independent board
(c) One 3 pin 5 Amp switch socket outlet on same board with accessories.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor.
S&F ceiling rose 3 terminal/ PVC/ Polycarbonate, isolated body.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair Modular switch single pole one way 6 Amps 1 module 240 V,complete all as specified and as directed.
S&F in repair Modular Socket, 6A - 2/3 pin combined 2 module 240 V,complete all as specified and as directed.
S&F in repair Modular Switch socket Combination 16A, 6 pin, 3 module 240 V,complete all as specified and as directed.
S&F in repair Lamp holder, insulated body, threaded dome pattern, suitable for bracket fittings, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B' Curve miniature circuit breaker (MCB) of single poles and current carryíng capacity 6 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 10 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 24OV, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 16 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 20 AMP, in the MCB DB Complete with conrnection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 AMP, in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity 32 Amp SPN in the MCB DB Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA 'C curve miniature circuit breaker (MCB) of two poles and current carrying capacity 40 Amp SPN in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA 'C curve miniature circuit breaker (MCB) of two poles and current carrying capacity 63 Amp SPN in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of four poles and Current carying capacity 63 Amp TPN in the DB complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP_42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP 42 protection,double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair LED bulb thread/pin type of capacity 10 Watt,
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150mm. Complete all as specified and as specified and as directed.
S&F in repair Sub main wiring using two runs of single core PVC insulated cable with FRLS copper conductor multistranded 1100 volts of sizes 6.0 Sgmm through existing/ new in wall with PVC conduit including copper earth wire in green colour of size 6.0 Sgmm connection to DB with thimbling complete as specified and directed. (Note:- Two runs of sub main wire including earth wire and rigid non metalic PVC conduit shall be measured as one unit per RM make of cable) Contractor must make wall/ceiling cheasel cutting and after fixing make surface good as it is.
Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sledges, blockages, dust, etc all as specified and as directed.
M&L for repairs to water heater inner vessel including brazing, welding, testing for a pressure of 3kg/ Sq.cm., re-assembling of any capacity Geysers complete all as specified and as directed.
S&F switch piano flush type, single pole, one way 6 amp 240 volts, 50 Hz complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed.
S&F Socket outlet 2 in 1, 3 pin, 5 Amps, box type complete all as specified and as directed
S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp Box type ,universsal complete all as specified and as directed
S&F Switch socket combination 2 in1, 3 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed.
S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified and as directed.
S&F in repairs Bell Push 5 Amp, flush type complete all as specified and as directed.
S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed.
S&F in repair LED 12W down light Decorative, surface mounting, dome shaped pendant in green & black finishes complete all as specified and as directed.
S&F in repir LED 7.5W down light Decorative, surface mounting, dome shaped pendant in green & black finishes complete all as specified and as directed.
S&F in repair LED 10W surface Bed/track light complete all as specified and as directed.
S & F foot light 5W complete all as specified and as directed.
S&F 6W LED panel round/square type, Slim, compact, auminum die cast edge lit panel, Recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed
S&F 2W LED panel round/square type, Slim, compact, auminum die cast edge lit panel, recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed.
S&F 15 W LED panel round/square type, Slim, compact, auminum die cast edge lit panel, Recess mounted round fixture with opal diffuser and separate electronic driver including connecting cable of suitable size complete all as specified and as directed.
S&F 36/40 Watt Warm/Cool LED ultra modern recess mounted luminaire (2'x2'), environmental friendly, new generation,aesthetically designed, with high brightness complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 150 mm complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 200 mm complete all as specified and as directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250 mm complete all as specified and as directed.
S&F Distribution board, SPN 2 way, single door complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, 240 Volts, C Curve complete all as specified and directed.
S & F in repairs MCB TPN 40 amp rating 240V, 10KA 'C' curve complete with connection testing and commissioning complete all as specified and as directed
M&L sub main wiring with two run single core 4 FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC grade ISI conduit/casing caping, medium marked with all accessories such as Tees, elbows, junction boxes etc, as required |fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch |board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM
M&L sub main wiring with two run single core 10 Sqmm FRLS copper conductor cable PVC insulated, 1100 V including 20 mm dia PVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 10 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed. Note: Two runs of 10 sqmm and one run of 10 sqmm cable and one run of casing capping shall be measured as one RM
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 6 sqmm all as specified and as directed.
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 10 sqmm all as specified and as directed.
S&F 1100 V grade heavy duty cable with pvc insulated aluminium conductor served with an inner sheathing of pvc tape and overall pvc sheathed in service connection suspended by insulating hangers not more than 1mtr apart including 4mm suspension wire one twin core cable flat or circular of size 16 sqmm all as specified and directed
S&F in repair capacitor 1.5/2 mfd suitable for 1200mm sweep ceiling fan complete all as specified and as directed.
S&F heating element including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape (triangular/round/spiral) complete all as specified and directed.
S&F heating element including rubber gasket & washer etc of capacity 2 KW suitable for exísting make and shape (triangular/round/spiral) complete all as specified and as directed.
S&F Thermostat including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35 / 50 Itrs including taking down existing unserviceable thermostat complete all as specified and as directed.
S&F PVC connecting pipe 18"/24" long with brass adopters for cold/hot water and connecting up with complete for 25 /35 /50 Itrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed.
S&F base assembly complete with inlet, outlet thermostat pipes, drain plug and screws for fixing the element suitable for any make and capacity Geysers complete with nuts, bolts and rubber gasket including taking down existing unserviceable base assembly complete all as specified and directed.
Supply only Copper Conductor 1.5 Sqmm multistranded FRLSH complete all as specified and as directed.
Supply only Copper Conductor 2.5 Sqmm multistranded FRLSH complete all as specified and as directed.
Supply only Copper Conductor 4 Sqmm multistranded FRLSH complete all as specified and as directed.
Supply only Copper Conductor 6 Sqmm multistranded FRLSH complete all as specified and as directed.
Supply only Casing Caping of size 25mm complete all as specified and as directed.
Note:- Schedule of credit Rs 1,86,340.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S GHULAM RASOOL LONE
Javeed And Co
M/S Khan Hussain & Co.
QAZI SONS
M/s Habib Electronics
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .