| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-Finance | L1 | Accepted-Finance L1 | |
| 2 | L2₹10.0 L+₹2,166 (0.22%)Accepted-Finance NEAR TELEPHONE EXCHANGE BIJROL ROAD BARAUT U P PATEL NAGAR BARAUT 250611 DISTT BAGHPAT | BAGHPAT | UTTAR PRADESH | 250611 | L2 | Accepted-Finance L2 | |
| 3 | L3₹10.0 L+₹9,822 (0.99%)Accepted-Finance | L3 | Accepted-Finance L3 | |
| 4 | Not Admitted-Fee/PreQual/Technical B 43 CIVIL LINES 1ST FLOOR NAYAPURA KOTA RAJASTHAN 324001 UDYAM RJ 24 0019224 08ABKPA3675N1Z9 R M | KOTA | RAJASTHAN | 324001 | - | Not Admitted-Fee/PreQual/Technical Others-EMD AND TENDER FEE NOT SUBMITTED |
| Sl No | Description | Qty | Unit | M/S AJAY TOMAR CONTRACTOR L2 | om sai contractor L1 | dharmendra chaudhary L3 |
|---|---|---|---|---|---|---|
| 1.00For preventive maintenance at132/33 KV S/s Purkul, work of Daily/Routine maintenance activities through round the clock availability of highly skilled personnel (03 Nos.) for | ||||||
| 1.01 | 132 kV Switchyard:- (1) 132 KV Bays- 06 Nos. (2) 132 KV Main Bus- 01 No. (3) 132 KV Transfer bus- 01 No. (4) Power Transformers- 02 Nos.2x40MVA(132/33kV) 132/33 kV Switchyard:- (1) 33 KV Bays- 10 Nos. (2) 33 KV Main Bus- 03 No. (3) 33 KV Transfer Bus– 01 No. (4) Control Room (5) Battery set and Battery Charger, ACDB and DCDB Work Comprises:- 1. Submission of daily activity/action taken report. 2. For above maintenance/scope of work, everyday 03 Nos. highly skilled and experienced Personnels (01 Nos. Skilled and 2 Nos.Unskilled) shall remain available at the Substation.(24 Days/ Month x12Months=Total 288 Days) Scope of Work:- (1) Routine visual checking, Thermo-scanning of Red-hot points, Flash points,Burned Jumpers, CBs, Isolators, Bus Bars, CTs/PTs/CVTs, Marshalling Box etc. including Scheduled Cleaning/Dusting, Lubrication, Tightening of Connections/Jumpers, replacement of minor damaged parts of equipments, replacement of Jumpers/Clamps/Connectors etc.as per site requirement. (2) Routine work of all Power and Station Transformers, maintenance of their cooling fans, i.e. Oiling, Greasing andCleaning/Dusting etc., LT electrical connections, cleaning of oil collection pits, tightening of loose connections, replacing silica gel, providing help in Oil top up of C.T/CVT/P.T. etc. ofas per directions of engineer in charge. (3) Routine checking of complete length of control cable and power cables between indoorpanels/equipments and outdoor panels/equipments, cleaning of cable Trench replacement of damaged/burned cable, tightening and replacement of damaged terminals/connections/lugs etc, re-ferruling whenever required. (4) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room, battery cells, Battery chargers, applying of petroleum jelly etc complete in all respect. (5) Routine maintenance of indoor panels i.e. C&R Panels, ACDB, DCDB system, indoor and outdoor illumination system etc including schedule cleaning, Lubrication, tightening of connections/terminals, replacement of minor damaged parts of panels tracing of circuits. | 288 | DAYS | 2,363 ₹6,80,544 | 2,356 ₹6,78,528 Lowest | 2,400 ₹6,91,200 |
| 1.02 | Replacement of 33KV outdoor type single phase oil cooled live tank CT having ratio 800/400/1 class 0.2S Burden 20VA, in confirmation to IS:2705/1992 includes Supply, Erection, Testing and Commissioning. | 3 | NOS | 1,05,000 ₹3,15,000 | 1,04,950 ₹3,14,850 | 1,04,000 ₹3,12,000 Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
8 Jan 2025, 6:00 pmClosed
SE O AND M CIRCLE DDUN
SE O AND M CIRCLE DDUN
Annual Preventive Maintenance work at 132KV 33KV Substation Purkul along with CT Replacement work
2024_PTCUX_78911_1
T 36 SE O and M CR D Dun 2024 25
Open Tender
Electrical Works
Item Wise
365 days
WORK
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE O AND M DIV YAMUNA COLONY PTCUL DDUN
₹30,000
20 Aug 2025
19 Dec 2024
10 Jan 2025
19 Dec 2024
8 Jan 2025
19 Dec 2024
Amount
For preventive maintenance at132/33 KV S/s Purkul, work of Daily/Routine maintenance activities through round the clock availability of highly skilled personnel (03 Nos.) for
132 kV Switchyard:- (1) 132 KV Bays- 06 Nos. (2) 132 KV Main Bus- 01 No. (3) 132 KV Transfer bus- 01 No. (4) Power Transformers- 02 Nos.2x40MVA(132/33kV) 132/33 kV Switchyard:- (1) 33 KV Bays- 10 Nos. (2) 33 KV Main Bus- 03 No. (3) 33 KV Transfer Bus– 01 No. (4) Control Room (5) Battery set and Battery Charger, ACDB and DCDB Work Comprises:- 1. Submission of daily activity/action taken report. 2. For above maintenance/scope of work, everyday 03 Nos. highly skilled and experienced Personnels (01 Nos. Skilled and 2 Nos.Unskilled) shall remain available at the Substation.(24 Days/ Month x12Months=Total 288 Days) Scope of Work:- (1) Routine visual checking, Thermo-scanning of Red-hot points, Flash points,Burned Jumpers, CBs, Isolators, Bus Bars, CTs/PTs/CVTs, Marshalling Box etc. including Scheduled Cleaning/Dusting, Lubrication, Tightening of Connections/Jumpers, replacement of minor damaged parts of equipments, replacement of Jumpers/Clamps/Connectors etc.as per site requirement. (2) Routine work of all Power and Station Transformers, maintenance of their cooling fans, i.e. Oiling, Greasing andCleaning/Dusting etc., LT electrical connections, cleaning of oil collection pits, tightening of loose connections, replacing silica gel, providing help in Oil top up of C.T/CVT/P.T. etc. ofas per directions of engineer in charge. (3) Routine checking of complete length of control cable and power cables between indoorpanels/equipments and outdoor panels/equipments, cleaning of cable Trench replacement of damaged/burned cable, tightening and replacement of damaged terminals/connections/lugs etc, re-ferruling whenever required. (4) Routine maintenance of battery cells and battery chargers i.e. daily cleaning of battery room, battery cells, Battery chargers, applying of petroleum jelly etc complete in all respect. (5) Routine maintenance of indoor panels i.e. C&R Panels, ACDB, DCDB system, indoor and outdoor illumination system etc including schedule cleaning, Lubrication, tightening of connections/terminals, replacement of minor damaged parts of panels tracing of circuits.
Replacement of 33KV outdoor type single phase oil cooled live tank CT having ratio 800/400/1 class 0.2S Burden 20VA, in confirmation to IS:2705/1992 includes Supply, Erection, Testing and Commissioning.
M/S AJAY TOMAR CONTRACTOR (BID ID -355184)
dharmendra chaudhary (BID ID -355221)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .