Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.3 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹8.7 L+₹43,880.54 (5.29%)Admitted-Finance | L2 | Admitted-Finance | ||
| 3 | L3₹8.8 L+₹47,781.03 (5.76%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹9.4 L+₹1.2 L (14.0%)Admitted-Finance H NO 29 FIRST FLOOR MASJIT MOTH SOUTH EXTENSION PART II DELHI 110049 | DELHI | SOUTH DELHI | DELHI | 110049 | L4 | Admitted-Finance | ||
| 5 | Rejected-Technical WZ 66 SRI NAGAR RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | - | Rejected-Technical not eligible |
Tender Value
₹9.8 L
EMD Value
₹19,502
Closing Date
27 Jan 2026, 1:00 pmClosed
Executive Engineer
12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007
Replacement of defective fittings , wiring , switch boards and other allied work at Ist and IInd Floors (stacks Hall) of Central Science Library , University of Delhi
2026_DU_893525_1
CEET-7226
Open Tender
Electrical Works
Supply
20 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
₹19,502
13 Mar 2026
12 Jan 2026
28 Jan 2026
12 Jan 2026
27 Jan 2026
12 Jan 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: Engineering Department, University of Delhi.
Name of Work: : - Replacement of defective fittings , wiring , switch boards and other allied work at Ist and IIrd Floor stacks of CSL , University of Delhi
Contract No: CE/ET- 7226 /DU/EM- (2025-26) dated:- 12-01-2026
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. BI01010001010000000000000515BI0100001112 1 Construction of chamber for 100mm sluices valve item1 10 1 Nos
_(* #,##0.00_);_(* \(#,##0.00\);_(* "-"??_);_(@_) Group C BI01010001010000000000000515BI0100001113 60 Each 894 Excess(+) Full Conversion INR INR Fifty Three Thousand Six Hundred & Forty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd. BI01010001010000000000000515BI0100001114
_(* #,##0.99_);_(* \(#,##0.99\);_(* "-"??_);_(@_) 6 Module (200mmX75mm) BI01010001010000000000000515BI0100001115 25 Each 402 Excess(+) Full Conversion INR INR Ten Thousand &Fifty Only
_(* #,##0.00_);_(* \(#,##0.00\);_(* "-"??_);_(@_) 12 Module (200mmX150mm) BI01010001010000000000000515BI0100001116 15 Each 547 Excess(+) Full Conversion INR INR Eight Thousand Two Hundred & Five Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001117
_(* #,##0.99_);_(* \(#,##0.99\);_(* "-"??_);_(@_) 5/6 amps switch BI01010001010000000000000515BI0100001118 90 Each 103 Excess(+) Full Conversion INR INR Nine Thousand Two Hundred & Seventy Only
_(* #,##0.00_);_(* \(#,##0.00\);_(* "-"??_);_(@_) 3 pin 5/6 amps socket outlet BI01010001010000000000000515BI0100001119 15 Each 148 Excess(+) Full Conversion INR INR Two Thousand Two Hundred & Twenty Only
_(* #,##0.99_);_(* \(#,##0.99\);_(* "-"??_);_(@_) 15 /16 amps switch BI01010001010000000000000515BI0100001120 50 Each 156 Excess(+) Full Conversion INR INR Seven Thousand Eight Hundred Only
_(* #,##0.00_);_(* \(#,##0.00\);_(* "-"??_);_(@_) 6 pin 15/16 amp socket outlet BI01010001010000000000000515BI0100001121 50 Each 197 Excess(+) Full Conversion INR INR Nine Thousand Eight Hundred & Fifty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. BI01010001010000000000000515BI0100001122
_(* #,##0.99_);_(* \(#,##0.99\);_(* "-"??_);_(@_) 3 x 4 sq.mm BI01010001010000000000000515BI0100001124 180 Metre 206 Excess(+) Full Conversion INR INR Thirty Seven Thousand &Eighty Only
_(* #,##0.00_);_(* \(#,##0.00\);_(* "-"??_);_(@_) 3 x 6 sq.mm BI01010001010000000000000515BI0100001125 90 Metre 304 Excess(+) Full Conversion INR INR Twenty Seven Thousand Three Hundred & Sixty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. BI01010001010000000000000515BI0100001126 12 Each 2730 Excess(+) Full Conversion INR INR Thirty Two Thousand Seven Hundred & Sixty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supplying regulator and on fixing the two module stepped type electronic fan existing modular plate switch box connections but excluding modular plate etc. as required. BI01010001010000000000000515BI0100001127 12 Each 369 Excess(+) Full Conversion INR INR Four Thousand Four Hundred & Twenty Eight Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design,18 Watt, 2100lm, 50000 burning hours, size 1200mm in existing single box or double box fittings complete as required. tube equivalent to Philips Make, Cat No.MAS LED tube 1200mm 18 W 856 TBI-2100lm BI01010001010000000000000515BI0100001128 80 Each 847 Excess(+) Full Conversion INR INR Sixty Seven Thousand Seven Hundred & Sixty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supply, Installation, testing and commissioning of pre-wired, Double box fitting with Two no. LED tube of frosted cover design,18 Watt, 2100lm, 50000 burning hours, size 1200mm complete i/c accessories etc. directly on ceiling/wall, including connection with 1.5 sqmm FRLS PVC insulated, copper conductor cable and earthling etc. as required. Fitting equivalent to Philips Make, Cat No.TMC 502 2XT-LED 22W, tube equivalent to Philips Make, Cat No.MAS LED tube 1200mm 18 W 856 TBI-2100lm BI01010001010000000000000515BI0100001129 180 Each 2652 Excess(+) Full Conversion INR INR Four Lakh Seventy Seven Thousand Three Hundred & Sixty Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) S/F snap-in DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as flat angle, end caps, internal/ external angle etc. as required at site. BI01010001010000000000000515BI0100001130 60 Metre 2280 Excess(+) Full Conversion INR INR One Lakh Thirty Six Thousand Eight Hundred Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supplying and fixing of 63Amp, Four pole, (three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. Equivlant to make legrand Cat. Nos 4118 83. BI01010001010000000000000515BI0100001131 6 Each 5479 Excess(+) Full Conversion INR INR Thirty Two Thousand Eight Hundred & Seventy Four Only
_(* #,##0_);_(* \(#,##0\);_(* "-"??_);_(@_) Supply, Installation,testing and comissioning of 12 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required BI01010001010000000000000515BI0100001132 12 Each 3778 Excess(+) Full Conversion INR INR Forty Five Thousand Three Hundred & Thirty Six Only
Total in Figures INR Nine Lakh Seventy Five Thousand One Hundred & Twenty Three Only 4 Construction of chamber for 100mm sluice plates item5 10 Nos
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.45 MB
BOQ_939175.xls
BOQ • 4.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .