Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.1 LAccepted-AOC 102 SUBHASH ROAD HERITAGE HEIGHTS DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹79.1 L | L1 | Accepted-AOC AOC |
| 2 | L2₹80.0 L+₹96,992 (1.23%)Rejected-AOC | ₹80.0 L+₹96,992 (1.23%) | L2 | Rejected-AOC Reject |
Tender Value
₹80.1 L
EMD Value
₹1.6 L
Closing Date
26 Dec 2024, 12:00 pmClosed
General Manager (Garhwal)
Office of Chief General Manager, Construction Wing, Uttarakhand Peyjal Nigam, Kamla Nagar(Opp. ONGC Hospital), Dehradun
Electrification And HVAC work for squash court at Maharana Pratap Sports College Raipur Dehradun
2024_MDPEY_78692_1
4931/Nivida(Garh)Elect.DDun/37 Dt.11/12/24
Open Tender
Electrical Works
Item Rate
365 days
RAIPUR
Please refer tender doucment
3 documents required · 3 mandatory
₹4,720
PM,Const.Unit(Elect.),UKPJN, Dehradun
₹1.6 L
Dehradun
29 May 2025
13 Dec 2024
27 Dec 2024
13 Dec 2024
26 Dec 2024
16 Dec 2024
14 Dec 2024
Amount
DSR 1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
DSR 1.10.3 Group C
DSR 1.14 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
DSR 1.14.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
DSR 1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
DSR 1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
DSR 5.4 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
DSR 5.9 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
DSR 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
DSR 2.4.2 6 way (4 + 18), Double door
DSR 2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
DSR 2.2.15 200 A,36KA,FPMCCB (160 to 200)
DSR 2.5 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
DSR 2.5.3 12 way (4 + 36), Double door
DSR 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR 2.10.1 Single pole
DSR 2.10.5 Triple pole and neutral
DSR 2.13 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR 2.13.1 40 amp
DSR 7.1 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.
DSR 7.1.1 Above 95 sq. mm and upto 185 sq. mm
DSR 9.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
DSR 9.1.25 3½ X 120 sq. mm (45 mm)
DSR 1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
DSR 4.3 Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
DSR 4.3.1 100 mm width X 50 mm depth X 1.6 mm thickness
DSR 4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness
DSR 4.3.6 450 mm width X 50 mm depth X 2.0 mm thickness
Non Schedule Supply of 3.5 c x 120 sq.mm aluminium armoured cable
Non Schedule Supply of 200W High Efficacy LED Highbay luminaire with Pressure Die casted Aluminium Housing and Polycarbonate high transmitivity IP Lens with shatter proof design. The luminaire should have a CRI>=70 and CCT of 5700K. The luminaire should have IP66 protection and impact protection of IK08 to ensure durablility. Luminaire should have 30000 system lumens at a system efficacy of at least 150 lumen/watt. Specially design heat sink for better thermal management. Burning hours of fitting should be 100000 hours with surge protection of 6Kv
Non Schedule Supply ,Installation ,Testing , commissionig and aiming of 2x2 Recess mounted LED Luminaire having system wattage of 36W made of CRCA Powder coated body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 4320 Lumens with a system efficacy of 120Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of > 85%, THD< 10% and P.F>0.95. Surge Protection sholud be Upto 4Kv
Non Schedule Supply ,Installation ,Testing , commissionig and aiming of round surface mounted LED Luminaire having system wattage of 24W made of Pressure die cast Aluminium body. The Luminaire should have optical cover made of HETpolycarbonate.The Lumiaire should have IP20 for Ingress protection. The Lumiaire life shall be 50000 burning hours @ L70 criteria. The Luminiare shall deliver 2400 Lumens with a system efficacy of 100Lm/w. The Luminaire shall have CCT of 5700K and CRI not less than 80. the Drivers should be BIS certified with efficiency of > 85%, THD< 20% and P.F>0.90. Surge Protection sholud be Upto 3Kv
Non Schedule Supply of Voltas Make VRF ODU Units
Outdoor Unit OF 14HP- Heat Pump Unit
Non Schedule Supply of Voltas Make VRF Indoor Units
Ductable Unit 11Tr High Stat. (Wired Remote)
Non Schedule Installation of airconditioning system of following items
Installation of voltas Make Equipments
Outdoor unit installation
Indoor unit Installation
Lifting Shifting Of ODU
M.s frame of VRV ODU
Nitrogen Testing, Flushing of Copper Tubing
Scaffolding for working of false ceiling Duct work,Pipe laying
Non Schedule Refrigerant Piping, Drain Piping & Cabling Work
Commissioning of Air-Conditioning systems including Topping Refrigerant Gas per site requirements
Non Schedule Supply, Installation, testing and commissioning of the insulated refrigerant piping for all the units with the refnets as per the specs. The insulation shall be of 13/19 mm thick nitrile rubber make through out the running length of the refrigerant piping. The piping shall be well supported at specifications
Copper Piping for VRV
Non Schedule Providing and fixing rigid PVC piping complete with fittings, supports as per OEM STD and duly insulated with 6 mm thick closed cell nitrile rubber insulation.
25 mm dia
Non Schedule Supply & fixing of control cum transmission wiring of shielded Copper conductor cable alongwith Pvc conduit for looping between indoor & outdoor VRF system & to main Central remote controller system
4 C X 1.5 Sq. mm
Non Schedule Cable trya
Non Schedule Chiseling
Non Schedule Air Distribution Work
Ducting
Non Schedule Supply, fabrication, installation and testing of G.S.S. sheet metal ducting complete with vanes etc. as required & as per approved shop drawings.
G.I. Sheet Metal Ducting Site Fabricated
24 Gauge
Non Schedule Insulation
Supply, installation and testing of 0val ducting insulation of 9mm complete with vanes etc. as required & as per approved shop drawings.
Non Schedule Grilles/Diffusers
Supply, Installation and Testing of return air grilles/ diffusers as per specifications and drawings.
Aluminium supply/ Return air grill without damper
Non Schedule Providing and fixing fire retardant nonporous double layer flexible connection between each unit and duct.
Non Schedule False ceiling modification/ repair works
Budhiraja Electricals (BID ID -353223)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .