Loading…
Loading…
Tender Value
₹1.9 Cr
EMD Value
₹2.5 L
Closing Date
21 Mar 2025, 11:00 amClosed
Replacement of leaning mast & Provision of Electrification of un-wired line in Dhanbad Division
TRD-OT-15-LEAN-MAST-24-25
TRD-OT-15-LEAN-MAST-24-25
Open
Works - General
6 Months
Dhanbad, Jharkhand
₹0
₹2.5 L
27 Feb 2025
27 Feb 2025
Preparation of design of OHE
Supply of Galvanised steel structure for mast,dwarf mast etc.RDSO Specn.No. ETI/OHE/13(4/84)and IS:2062.
Erection of Galvanised steel structure for mast,dwarf mast etc.RDSO Specn.No. ETI/OHE/13(4/84)and IS:2062.
Supply of Galvanised steel structure other than mast RDSO Specn. No. ETI/OHE/13 (4/84) and IS:2062.
Erection of Galvanised steel structure other than mast RDSO Specn. No. ETI/OHE/13 (4/84) and IS:2062.
Supply of Cantilever assembly complete without insulator as per RDSO Spec.No.ETI/OHE/G/02106,SH-1&3 or latest
Erection of Cantilever assembly complete without insulator as per RDSO Spec.No.ETI/OHE/G/02106,SH-1&3 or latest
Supply of Bracket insulator (CD-1050 mm) as per RDSO Spec. No. TI/SPC / OHE/INS/ 0070(4/07) with A&C slip No.1&2 or latest.
Erection of Bracket insulator (CD-1050 mm) as per RDSO Spec. No. TI/SPC / OHE/INS/ 0070(4/07) with A&C slip No.1&2 or latest.
Supply of Stay insulator (CD-1050 mm) as per RDSO Spec. No.TI/SPC/ OHE/INS/ 0070(4/07) with A&C slip No.1&2 or latest.
Erection of Stay insulator (CD-1050 mm) as per RDSO Spec. No.TI/SPC/ OHE/INS/ 0070(4/07) with A&C slip No.1&2 or latest.
Supply of 9-T insulator (CD-1050 mm)as per RDSO Spec. No.TI/SPC/OHE/INS/ 0070(4/07) or latest.
Erection of 9-T insulator (CD-1050 mm)as per RDSO Spec. No.TI/SPC/OHE/INS/ 0070(4/07) or latest.
Supply of Regulating equipment (3:1 type) modified complete w/o insulator.
Erection of Regulating equipment (3:1 type) modified complete w/o insulator.
Supply of Fixed Terminal arrangement complete.
Erection of Fixed Terminal arrangement complete.
Supply of Guy rod assembly as per RDSO drg.No. ETI/OHE/P/ 5000 or latest.
Erection of Guy rod assembly as per RDSO drg.No. ETI/OHE/P/ 5000 or latest.
Supply of Section Insulator complete as per RDSO' specification No TI/SPC/OHE/LWTSI/0060 (08/06) or latest
Erection of Section Insulator complete as per RDSO' specification No TI/SPC/OHE/LWTSI/0060 (08/06) or latest
Erection of 65 sq.mm cadmium copper catenary wire (19/ 2.10mm) as per RDSO Specn. No. ETI/OHE/50(6/97) with A & C slip No. 1 to 3 or latest.
Erection of 107 Sq.mm Contact wire as per RDSO Specn. No. ETI/OHE/76 (6/97) with A&C slip No. 1, 3 & 4 or latest.
Supply of Large Span wire (Copper 130 Sq.mm)
Erection of Large Span wire (Copper 130 Sq.mm)
Supply of Mounting arrangement for large span wire (Without insulator)
Erection of Mounting arrangement for large span wire (Without insulator)
Supply of Catenery wire splice as per Drg. No.ETI/OHE/P/1090 or latest
Erection of Catenery wire splice as per Drg. No.ETI/OHE/P/1090 or latest
Supply of Contact wire splice as per Drg. No.ETI/OHE/P/1080-1 or latest.
Erection of Contact wire splice as per Drg. No.ETI/OHE/P/1080-1 or latest.
Supply of P.G. Clamp (1030) as per Drg. No.ETI/ OHE/ P/1030-3 & or latest
Supply of P.G. Clamp (1040) as per Drg. No.ETI/ OHE/ P /1040-2 or latest
Supply of 25 KV Single pole Isolator complete with earthing heel excluding post insulator as per RDSO Spec.No. ETI/OHE /16(1/94) Rev. 2 (Mar'04) or latest.
Erection of 25 KV Single pole Isolator complete with earthing heel excluding post insulator as per RDSO Spec.No. ETI/OHE /16(1/94) Rev. 2 (Mar'04) or latest.
Supply of Contact wire dropper clip as per Drg. No.RE/ 33/P/1180.
Supply of Catenery dropper clip as per Drg. No.RE/33/P/1192 or latest.
Supply of Dropper wire as per IS:282-1982 or latest (Drg.No.ETI/OHE/P/193).
Erection of Dropper wire as per IS:282-1982 or latest (Drg.No.ETI/OHE/P/193).
Supply of Jumper wire, 160 sq.mm (19x7x1.25 mm) as per RDSO Spec. No. ETI/OHE/3(2/94) Rev.1 (4/95) or latest.
Erection of Jumper wire, 160 sq.mm (19x7x1.25 mm) as per RDSO Spec. No. ETI/OHE/3(2/94) Rev.1 (4/95) or latest.
Supply of Gal. steel flexible traction wire bond with lug as per Spec.No. TI/SPC/OHE/GALSTB/0040 with A&C Slip No.1(8/2005) or latest ( Length -3.0M).
Erection of Gal. steel flexible traction wire bond with lug as per Spec.No. TI/SPC/OHE/GALSTB/0040 with A&C Slip No.1(8/2005) or latest ( Length -3.0M).
Supply of M.S. Flat 40 x 6mm (IS 2062) for traction bond.
Fabrication and Erection of M.S. Flat 40 x 6mm .
Drilling of rail hole for Bonding.
Supply of Retro reflective type OHE structure number plate including all fixing accessories.
Erection of Retro reflective type OHE structure number plate including all fixing accessories.
Supply of Post Insulator
Erection of Post Insulator
Supply of Retro Reflective type Public caution board as per Drg.No. ETI/OHE/P/ 7551 Mod-C or latest.
Erection of Retro Reflective type Public caution board as per Drg.No. ETI/OHE/P/ 7551 Mod-C or latest.
Supply of Retro Reflective type Staff caution board as per Drg.No. ETI/OHE/P/7561 Mod-B or latest
Erection of Retro Reflective type Staff caution board as per Drg.No. ETI/OHE/P/7561 Mod-B or latest
Supply of Retro Reflective type Caution plate 25000 V as per Drg.No. ETI/OHE/P/ 7531 Mod-C or latest.
Erection of Retro Reflective type Caution plate 25000 V as per Drg.No. ETI/OHE/P/ 7531 Mod-C or latest.
Supply of Caution unwired turn out as per Drg.No.ETI/OHE/P/ 7573 Mod-A or latest
Erection of Caution unwired turn out as per Drg.No.ETI/OHE/P/ 7573 Mod-A or latest
Supply of Electric engine stop board as per Drg.No.ETI/OHE/P/ 7572 Mod-B or latest
Erection of Electric engine stop board as per Drg.No.ETI/OHE/P/ 7572 Mod-B or latest
Supply of Contact ending clamp (1118,1119) as Per Drg.No. ETI/OHE /P/1110 MOD-D or latest.
Erection of Contact ending clamp (1118,1119) as Per Drg.No. ETI/OHE /P/1110 MOD-D or latest.
Supply of Catenery ending clamp as per Drg. No.RE/ 33/P/1120 or latest
Erection of Catenery ending clamp as per Drg. No.RE/ 33/P/1120 or latest
Earthing station (RI-7021) as per Drg.No. ETI/ OHE/P/ 7020 or latest
Concrete for Foundation Normal Soil.
Supply of Nylon/Plastic net in Portal booms as per latest RDSO specificatios.
Erection of Nylon/Plastic net in Portal booms as per latest RDSO specificatios.
Painting of SED value on mast/portal
Marking/painting of temperature & 'Y'- Measurment of OHE mast at BWA locations.
Dismantling of CLA complete set with insulator.
Dismantling of Guy rod complete set.
Dismantling of RE complete set & transportation upto nearest Depot.
Dismantling of traction mast & transportation upto nearest depot.
Supply & erection of sectioning /schematic diagram boards.
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .