Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.6 LAccepted-AOC | L1 | Accepted-AOC lowest tender | |
| 2 | L2₹51.6 L+₹12.0 L (30.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tender | |
| 3 | L3₹51.8 L+₹12.2 L (30.7%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tender | |
| 4 | L4₹52.7 L+₹13.1 L (33.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest tender | |
| 5 | L5₹54.0 L+₹14.3 L (36.1%)Rejected-Finance KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L5 | Rejected-Finance Other than lowest tender |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
8 Jun 2021, 6:00 pmClosed
GE NS KOCHI
Military Engineer Services, Garrison Engineer (Naval Services), Kataribagh, Naval Base Post, Kochi, 682 004.
REPAIR AND MAINTENANCE OF EXTERNAL WATER SUPPLY PUMPING LINES, SLUICE VALVES AND CONNECTED WORKS AT KATARIBHAGH AND NAVAL BASE KOCHI
2021_MES_443860_1
8800/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NS KOCHI
₹96,000
Yes
22 Jul 2021
19 May 2021
10 Jun 2021
19 May 2021
8 Jun 2021
28 May 2021
19 May 2021 - 27 May 2021
Amount
Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in soft/loose soil for laying pipes etc, including forming bottom surface to required level complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point complete all as specified and directed.
Taking up DI water mains 300 mm bore (including all fittings) with spigot and socket ends and, lead joints including burning out joint complete all as specified and directed.
All as per item No 4 here in above, but 250mm bore pipes.
All as per item No 4 here in above, but 200mm bore pipes.
All as per item No 4 here in above, but 150mm bore pipes.
All as per item No 4 here in above, but 100mm bore pipes.
Re-laying in trenches DI pipes of size 300mm with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using spitted bamboos/steel rod effectively (pipe taken out/obtained from item No. 5 here as above) complete all as following size as specified and directed by Engineer-in-Charge. Note- Rubber gasket joints/run lead joints and DI specials/fittings shall be measured and paid separately.
All as per item No 9 here in above, but 250mm bore pipes.
All as per item No 9 here in above, but for 200mm bore pipes.
All as per item No 9 here in above, but for 150mm bore pipes.
All as per item No 9 here in above, but for 100mm bore pipes.
Supplying and laying in trenches centrifugally cast (spun) ductile iron pipes of 300 mm dia suitable for pressurized water delivery with spigot & socket end, class 'K-9' conforming to IS:8329/2000 (latest version) - blast furnace slag cement with Portland cement properties suitable for (push on) rubber gasket jointing with inside cement mortar lining and black bitumen external coating, duly ISI marked in any length including taking down old unserviceable CI pipe and testing on completion, complete all as specified and directed.
All as per item No 14 here in above but of size 250mm bore pipes.
All as per item No 14 here in above but of size 200mm bore pipes.
All as per item No 14 here in above but of size 150mm bore pipes.
All as per item No 14 here in above but of size 100mm bore pipes.
Material and labour for ISI marked ductile iron socket fittings supplied as per IS: 9523/2000 of class K-12, PN-10 for pressurized water delivery with inside Cement Mortar lining and outside zinc followed by black bitumen coating for size 100mm dia to 300 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch, cross collars, caps and plug set including rubber ring push on joints complete as specified and directed.
All as per item No 19 here in above but for flanged fittings.
Cutting the existing CI/ DI pipes in position for insertion of new collars/ Tees /branches/new pipes 300 mm dia CI Pipe complete all as directed at site.
All as per item No 21 here in above but of size 250mm bore pipes.
All as per item No 21 here in above but of size 200mm bore pipes.
All as per item No 21 here in above but of size 150mm bore pipes.
All as per item No 21 here in above but of size 100mm bore pipes.
Repairing/replacing gland packing, nut bolts etc of sluice valve to make it leak proof for 300mm bore sluice valve, complete all as per specified.
All as per item No 26 here in above but of size 250mm bore.
All as per item No 26 here in above but of size 200mm bore.
All as per item No 26 here in above but of size 150mm bore.
All as per item No 26 here in above but of size 100mm bore.
Material and Labour for joint with rubber gasket joint of 300mm bore DI spigot and socketed pipes/fittings complete all as directed.
All as per item No 31 here in above but of size 250mm bore.
All as per item No 31 here in above but of size 200mm bore.
All as per item No 31 here in above but of size 150mm bore.
All as per item No 31 here in above but of size 100mm bore.
Supply and fix in replacement of 200 mm bore cast iron sluice valve with flanged ends of type PN-1.6 conforming to IS-14846:2000 with cast iron wheel and brass spindle including taking down old unserviceable one complete all as specified and directed.
All as per item No 41 above but of size 150 mm dia.
All as per item No 41 above but of size 100 mm dia.
All as per item No 41 above but of size 80 mm dia.
Supply and Fix Cast iron Air release valve with two air outlets 100 mm bore and fixing up in cast iron water supply mains including taking down old unserviceable one complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all arches, pillars etc but excluding ashlars facings, dressed stonework and precast concrete article complete all as specified and directed.
Demolition of cement concrete (un reinforcement) in ground floors and paving not exceeding 15cm thickness, above ground level in inside the valve pits complete all as specified and directed.
Material & Labour for plain Cement concrete 100mm thick 1:2:4 type B2 (using 40mm graded aggregate) including finishing cement concrete surface even & smooth without using extra cement, complete all as specified and directed.
Material & Labour Pre-cast cement concrete block masonry, type C1 1:3:6 (using 20mm graded aggregate) with solid blocks, exceeding 10cm in width and setting in mortar complete built in cement mortar of 1:6 complete all as specified and as directed.
Material & Labour for Rendering 15 mm thick on fair faces of brick work or concrete surface, including even & smooth finish (without using extra lime or cement) using cement plaster of 1:4 complete all as specified and directed.
Supply and laying 75mm inner dia of CPVC pipes with CPVC Schedule 40 pipes & plain Schedule 80 fittings and jointed with CPVC primer & solvent cement including taking down old unserviceable GI Tubing ,laid in trenches, complete all as specified and directed.
Supply and laying 50mm outer dia CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings, including jointed with yellow solvents cement including taking down old unserviceable GI Tubing, laid in trenches complete all as specified and directed.
All as per item No 47 here in above, but 40mm dia of pipes.
All as per item No 47 here in above, but 25mm dia of pipes.
Supply and fix, 50mm outer dia of CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings and jointed with yellow solvents cement including taking down old unserviceable GI tubing, fixed to walls /ceiling or laying in floors complete all as specified and directed.
All as per item No 50 here in above, but 40mm dia of pipes.
All as per item No 50 here in above, but 25mm dia of pipes.
Supply and fixing 75 mm bore CPVC Ball valves Suitable for CPVC pipe with necessary fittings ,including taking down old one complete all as specified and directed.
All as per item No 53 here-in-before but 50mm dia pipes.
All as per item No 53 here-in-before but 40mm dia pipes.
All as per item No 53 here-in-before but 25mm dia pipes.
Material and labour for plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in foundations filling and mass concrete complete all as specified and as directed.
Supply and fixing 40 mm bore float valve synthetic (PVC) high pressure with polythene ball of size 6" dia and fly nut including taking out old one complete all as specified and directed.
Supply and fix in replacement of 50mm bore Gun metal Gate/Globe valve with iron wheel head, screwed both ends suitable for fixing with CPVC pipe, complete all as specified and as directed.
All as per item No 59 here-in-before but 40mm dia.
All as per item No 59 here-in-before but 25mm dia.
Testing of water as per table 1 Organoleptic and physical parameters of IS: 10500-2012 in a Govt approved laboratory all as specified and directed. Notes: - (i) Quality of water shall be tested (routine test) and test certificate to prove the portability of water issued by a Govt approved laboratory shall be produced by the contractor. The water shall be tested for essential characteristics, Bacteriological examination for routine test as laid down in IS: 10500-2012 and conform to the requirements. (ii) Sample of water shall be taken jointly once in a month by the representative of Engineer-in-Charge and contractor from any of the pump houses of Naval Base and Kataribagh Area on the guide lines given by Engineer in Charge.
Providing services of one ITI / ITC qualified Plumber / Electrician / mechanic / Fitter per each shift from 06:00 hrs to 06:00 hrs in three shifts of 08 hours each including Sundays and Holidays for operation of E/M installation at SFNA Drainage Pump House consisting of 52 HP Diesel Driven Pump Set, 16 HP Trolley mounted Diesel Driven Pump Set and valves and carry out minor repair as and when required to all machines / equipments and valves to ensure 100% serviceability of plants complete all as specified and directed.
Providing services of one ITI / ITC qualified Plumber / Electrician / mechanic / Fitter per each shift from 06:00 hrs to 06:00 hrs in three shifts of 08 hours each including Sundays and Holidays for operation of water supply installation of Garuda Dumping Yard Drainage Pump House Diesel Driven Pump Set 52 HP & Electric Driven Pump Set 100 pump sets and valves and carry out minor repair as and when required to all machines / equipments and valves to ensure 100% serviceability of plants complete all as specified and directed.
Providing services of one ITI / ITC qualified Plumber / Electrician / mechanic / Fitter per each shift from 06:00 hrs to 06:00 hrs in three shifts of 08 hours each including Sundays and Holidays for operation of water supply installation of Kataribagh Area Trolley mounted Diesel Driven Pump Set 16 HP & Electric Driven Pump Set 100 HP and valves and carry out minor repair as and when required to all machines / equipments and valves to ensure 100% serviceability of plants complete all as specified and directed.
Amount of Credit Schedule shall be deducted to arrive the Contract Sum.
N.O. Antony Contractors
SREENARAYANA ENTERPRISES
PHEJAYS AGENCIES
K.V.GEORGE AND COMPANY
ANIE JOHN CONTRACTORS
AAG INDIA PVT LTD
Green Ray Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .