Tender Value
₹5.3 L
EMD Value
₹10,700
Closing Date
25 Oct 2022, 2:00 pmClosed
Executive Engineer STD Ganderbal
Office of the Executive Engineer STD Ganderbal
Shifting of 33KV line from the inhabited population of Parray Mohalla Wahidpora To Middle School Wahidpora via Bund Road At Wahdipora in respect of STD Gandebal
2022_PDD_191681_1
STD GBL 29 OF 2022-23 Dated 10-10-2022
Open Tender
Electrical Works
Item Rate
30 days
Wahidpora Ganderbal
REFER SBD
10 documents required · 10 mandatory
₹1,000
Yes
Office of the Executive Engineer STD Ganderbal
₹10,700
Yes
4 Nov 2022
10 Oct 2022
27 Oct 2022
10 Oct 2022
25 Oct 2022
13 Oct 2022
10 Oct 2022 - 25 Oct 2022
Amount
Shifting of 33KV line from the inhabited population of Parray Mohalla Wahidpora To Middle School Wahidpora via Bund Road At Wahdipora
Supply, Carriage, Installation Testing and Commissioning of 11 mtr ST. Poles
Erection and fixing of dimantled 11 Mtr. Long ST poles including manual carriage from dismantled location to new site.
Supply ,Installation Testing and Commissioning of GI V cross-arm with top Bracket including clamps and braces /GI Channel X-arm including clamps and braces
Fixing of Channel cross arms/ Angle iron with clamps and braces including manual carriage from dismantled location to new site.
Supply, Installation commissioning of 0.1 ACSR Conductor
Laying of dismantled 0.1 ACSR conductor and allied material including manual carriage from dismantled location to new site.
Supply ,Installation Testing and Commissioning of PG Clamps for 100 mm² ACSR Conductor
Supply ,Installation Testing and Commissioning of 33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Re-erection of 33kV Pin insulators including manual carriage from dismantled location to new site.
Re-erection of 33kV Disc insulators WITH FITTINGS including manual carriage from dismantled location to new site.
Supply ,Installation Testing and Commissioning of 33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
Supply ,Installation Testing and Commissioning of Galvinized Nuts and Bolts
Supply ,Installation Testing and Commissioning of Danger Plates with Clamps
Supply ,Installation Testing and Commissioning of Anti-Climbing Device with Clamps
Supply ,Installation Testing and Commissioning of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing and Painting of Red Oxide paint on ST Poles as per REC standard
Providing and Painting of Aluminium paint on ST Poles as per REC standard
Providing , Laying of Cement bottoming 1:2:4 mix as per REC standards 0.6cum/pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (450x 450 x 8 mm), nutbolts, 2 Nos turn-buckles, 1.8m long,20 mm diameter solid GS stay rod & 7/4 mm dia GI stranded wire complete (33kV)
Guard netting
Dismantling of existing 11 mtr. ST Poles along with allied material including Channel iron/ angle iron/ V cross arms with f tops, pin insulator/ Disc insulators including carriage to the new site.
Dismantling of existing 0.1 ACSR conductor including carriage to the new site.
M/S WATT ELECTRICALS CONTRACTORS
M/S SALIQ TRADERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .