Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹9.7 L+₹2.6 L (37.4%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹10.0 L+₹3.0 L (42.6%)Rejected-Finance SHOP NO 13 MOHINI MARKET KISHORE BAGH MANDORE JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹10.6 L+₹3.6 L (50.8%)Rejected-Finance 06 KHASRA NUMBER 56 KIRAN NAGAR BASNI JODHPUR JODHPUR RAJASTHAN 342001 UDYAM RJ 22 0002214 | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹11.1 L+₹4.1 L (58.2%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
₹14.5 L
EMD Value
₹28,980
Closing Date
20 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer, Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR/MAINT OF STREET GARDEN LIGHTS AND ITS CONNECTED ITEMS AT RALAWAS UNDER GE BANAR
2023_MES_604718_1
8823/14/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Banar
PLEASE REFER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Garrison Engineer, Banar
₹28,980
Yes
17 Aug 2023
21 Jun 2023
22 Jul 2023
21 Jun 2023
20 Jul 2023
6 Jul 2023
Amount
M&L for checking/testing of street lights fittings any type fixed on pole, to detect the fault and make it functional after removal of minor fault like remove carbon, lose connection etc complete all as directed by Engineer-in-Charge.
Strip opening and taking down carefully defective/non functional street light fittings of LED's from its existing position & refixing the same after checking of serviceability and to make it functional i.e (the power supply can not be meet to driver/ flexible cable burnt from junction box to driver/ control MCB not working in junction box) of the fitting and re-assembling and testing complete all as specified. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately. (b) Contractor should provide Extendable wheel laddar or hydra to carryout repair and quoted rates deemed to includes this aspect.
S&F in replacement LED street light fitting 90 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant with thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified.
S&F in replacement LED street light fitting 60 watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp, bracket with impact and corrosion resistant with thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified.
Striping out and taking down carefully defective/non functional gate/garden light/post top lantern fittings of LED's from its existing position and capacity & refixing the same after checking of serviceability and to make it functional (i.e the power supply can not be meet to driver/ flexible cable burnt from control panel to driver) of the fitting as directed by Engr-in-Charge. Note :- (a) Other items i.e flexible cable to be measured and paid separately.
S&F in replacement Post top lantern LED type 20 watts 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as directed at site complete.
Striping out and taking down carefully defective/non functional LED flood light/bldg security light for > 10m high bldgs from its existing position and capacity & refixing the same after checking of serviceability and to make it functional (i.e the power supply can not be meet to driver/ flexible cable burnt from control panel/distribution box to driver/ control MCB not working in distribution box) of the fitting re-assembling and testing complete all as specified. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately. (b) Contractor should provide the extendable wheel ladder or hydra as required to carryout repair and quoted rates shall deemed to include this aspect.
Supply and fix in replacement MCB SP 6-32 Amps 230V 10KA 'C' curve all as specified.
Supply and fix in replacement of PVC insulated unsheathed flexible copper conductor flexible cable three core multi stranded 1.5 Sqmm all as specified.
Supply and fix in replacement thermoplastic cable junction box IP 65 with plain walls of size 210x310x116mm and making suitable size hole for cable entry complete with cable terminals/connectors and other fittings fixed on poles with MS flat iron nut bolts, washers and double compressor metal glands of suitable sizes etc all as specified.
M&L painting of LT/HT steel tubular pole any type size externaly above foundation including junction box and all MS work with one coat of aluminium paint after scraping /cleaning well the existing surface complete all as specified. Note :- The item also includes 3 Nos 30 cm wide bands black & Yellow with synthetic enamel paint in alternate strip upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide letter on base of yellow colour denotes HT/LT as per direction of Engr-in-Charge.
Supply and laying in trenches/on pole XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cable of following sizes including taking out old unserviceable cable from trench trenches/duct/ pipes/ wall and open surfaces all as specified. Note :- During the laying of cable minor accessories i.e lugs, nut-bolts and steel glands deemed to be fit inclusive in quoted rate.
16 Sqmm 4 core
10 sqmm 4 core
Rerouting of cable in trenches/on pole XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade of size 10/16 sqmm, 4 core with stranded aluminium conductor cable of following sizes including taking out from trench and again laid in trenches/duct/ pipes/ wall and open surfaces all as specified and directed by EIC. Note : (a) During the laying of cable minor accessories i.e lugs, nut-bolts and steel glands deemed to be fit inclusive in quoted rate. (b) Earth work shall be measured & paid separately.
Supply,fixing and testing in replacement of LED 45W driver with surge protection complete including connection to LED Flood/street/highbay light fitting with suitable wire as specified.
Supply,fixing and testing in replacement of LED 75W driver with surge protection complete including connection to LED Flood/street/highbay light fitting with suitable wire as specified .
Supply,fixing and testing in replacement of LED 100W driver with surge protection complete including connection to LED Flood/street/highbay light fitting with suitable wire as specified.
Supply,fixing and testing in replacement of LED 150W driver with surge protection complete including connection to LED Flood/street/highbay light fitting with suitable wire as specified.
Supply and fixing in replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fittingcomplete with connection as specified.
Supply and fixing in replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified.
Supply and fixing in replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified.
Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables all as specified.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in soft/loose soil complete all as specified.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point complete all as specified.
M&L for sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm before laying and 15 cm covering above the top edge of cable after laying complete all as specified . Note :- Punned thickness only shall be measured and paid.
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified.
Taking out existing old/rusted GI tubing of any size from pole/ trenches for necessary and Supply and lay light grade GI pipe with all fittings complete laid in trench/ fixed to Wall / Poles etc with suitable clamp, nuts, bolts washers etc required at site for protection of cable of the following sizes:-
25 mm dia
40 mm dia
50 mm dia
M&L PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified.
M&L PCC (1:3:6) type C-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified.
Material and labour for re-fixing of danger notice/safety board above HT/LT steel tubular/ PCC pole and to be maintained a suitable ht from ground level with proper alignment including Digital printed on retro reflective sheet (letter should be not less than 5CM in Red Colour) in HIndi and english both language all as specified. Note :- Old two number of MS clamps including nut-bolts suitable for steel tubular/PCC pole to be replaced by new one and quoted rate deemed to includes this aspect.
Supply and fix in replacement GI bracket of medium grade 40 mm bore GI tubing not less than 1.50 mtr long bend to required shape as in bracket for street light fittings fixed with two pair of MS flat iron clamp suitable for steel tubular/PCC pole as per site requirement with 4mm thick and including accessories i.e new nut-bolts and washers and other petty items required for fixing including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified.
Supply and fix in replacement MCCB 4 Pole 100A Amps 415V 16KA all as specified.
Trimming and cutting of tree branches coming across LT over head line, clearing the line around 1.5m and disposal of shrubs to a distance up to 500mtr distance and cleaning the site complete all as directed. Note :- (i) Length of span shall be 45 to 50m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible. Note : All T&P shall be provoded by contractor
M & L in repair for rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Supplied & fixed External dia in 20 mm, complete all as specified and as directed by the Engineer-in-Charge
M & L in replacement for earthing complete with galvanised steel earth plate electrode 60cmx60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion,, complete all as specified and as directed by the Engineer-in-Charge
M & L in replacement for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire,, complete all as specified and as directed by the Engineer-in-Charge
Dismantling & taking down of old/rusted/broken PCC/steel pole from its existing position and Supply & fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) complete all as specified.
M&L for dismantling PCC for coping/base foundation of PCC/steel tubular pole complete all as specified.
S&F in reapir of cable lugs upto 25mm size properly fixing in junction box (incoming and outing boths cable ) properly tighting complete all as specified.
S&F in reapir of Connector three phase with netural upto 40Amp properly fixing in junction box suitable for incoming and outgoing cables properly tighting complete as per specified.
M&L for locking system at junction box with suitable clamps for fixing the box as site requirment complete all as specified.
M&L in replacement for Danger notice plate of 1.6mmthick mils steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal redcolour and fixed wih M.S clamps bolts and nuts of approved size for LT20x15cm size with complete all as specified.
Supply & fix in replacement Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
Supply and fixing in repair of 18 Amps Contactor MNX18 with 1 NO 3 Phase complete all as specified.
Shri Electrical Enterprises
Sachiyay maa Electricals
new india engineers
M/s Vishaka Enterprises
vinayandsons
Tirupati electricals works and services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .