Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.3 LAccepted-AOC DOOR NO 57 28 10 4 2 BHAVANI GARDENS INDUSTRIAL ESTATE POST VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L1 | Accepted-AOC Being Lowest Vendor | |
| 2 | L2₹31.8 L+₹57,135 (1.83%)Rejected-Finance D NO 65 6 500 2 MULAGADA COLONY HIMACHALNAGAR GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹31.9 L+₹61,961 (1.98%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹33.6 L+₹2.3 L (7.33%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹43.5 L+₹12.3 L (39.2%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | aswitha engineering works L4 | ANAND ENTERPRISES AND ENGINEERS L2 | B SRINIVAS L1 | A BALA RAJU L5 | UV POWER TECH L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Attending to transformer complain 24 hrs of capacity upto 1250 KVA tripping including meggaring of the cables and checking the physical condition of the transformer and assessing the physical condition and, checking oil level, conducting electrical LT testing like, measuring of IR values, ratio test, magnetic balance test, oil BDV test to assess the healthness of the windigs and if found statiafactory, then connections of the cable terminations and make arrange for charging the transformer.If transformer is found faulty, then recommend for the further repair/rewinding works to be carried out to put back the transformer into serviceall as specified and directed. | 30 | Each Job | 3,300 ₹99,000 | 3,250 ₹97,500 | 3,000 ₹90,000 Lowest | 5,000 ₹1,50,000 | 5,500 ₹1,65,000 |
| 2.00 | All as per item No. 1.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 16 | Each Job | 2,800 ₹44,800 Lowest | 3,860 ₹61,760 | 3,500 ₹56,000 | 6,000 ₹96,000 | 5,800 ₹92,800 |
| 3.00 | Overhauling of transformers of capacity upto 1250 KVA openning of top cover in situ or at wksp by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for repair/replacement of HT/LT bushings, tap changer, physical check of any defects, for lifting of core assy, for cleanning/repair and refixing top cover complete with RC 70 C rubberised cork sheet gusket sheet , existing/new nuts, bolts & washers for transformer indoor/outdoor type,The transformer to be put inside the hearting chamber for IR values imporvement, refilling of oil for transformer all as specified and directed.
Note:- (a) HT/LT bushings, Studs, tap changers, nuts, bolts & washers required new shall be mesured separately here-in-after (b) Silicon oil proof gusket shall be inclusive of quoted rate. (c) Transportation and loading and unloading charges to be measured and paid included. | 5 | Each Job | 17,662 ₹88,310 | 16,300 ₹81,500 | 15,000 ₹75,000 | 15,000 ₹75,000 | 8,044 ₹40,220 Lowest |
| 4.00 | All as per item No. 1.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 8 | Each Job | 24,527 ₹1,96,216 | 19,300 ₹1,54,400 | 10,000 ₹80,000 Lowest | 22,000 ₹1,76,000 | 10,012 ₹80,096 |
| 4.01Note for serial item Nos. 3 & 4 :- (a) New transformer oil to be bought in company sealed ISI marked container with test certificate (b) Filtration /dehydration of transformer oil shall be carried out at the location where transformer is installed and required pipe connection from filter machine to transformer shall be made and rate shall be inclusive of quoted rate. (c) Necessary filter/dehydration plant having pressure gauge, hour meter, temperaturature gauge to be brought at site by contractor and to be kept permanently inside ND (V) till completion of work and rate deemed to be included in the quoted rate. In any condition, in-out of the filter machine during the progress of the work will not be allowed. (d) Transformer oil test report before and after dehydration/filtration shall be submitted duly authenticated by authorised person . | ||||||||
| 5.00 | M & L for filtration/dehydration transformer oil of transformer voltage grade 11/0.415 KV, capacity 200 KVA to 3000 KVA indoor/outdoor type, floor mounted in situ till achieve dielectric strength minimum 40 KV at 4mm gap all as specified and directed. | 40,000 | Ltr | 7 ₹2,80,000 | 8 ₹3,20,000 | 10 ₹4,00,000 | 6.5 ₹2,60,000 Lowest | 7 ₹2,80,000 |
| 6.00 | M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. | 4,200 | Ltr | 125 ₹5,25,000 | 126 ₹5,29,200 | 125 ₹5,25,000 | 145 ₹6,09,000 | 120 ₹5,04,000 Lowest |
| 7.00 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 11 KV grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 12 | Each | 1,861 ₹22,332 | 1,630 ₹19,560 Lowest | 2,500 ₹30,000 | 4,500 ₹54,000 | 2,513 ₹30,156 |
| 8.00 | All as per item No. 7.00 above, but for transformer capacity 1500 KVA to 2500 KVA, 11/0.415 KV | 15 | Each | 2,254 ₹33,810 | 1,820 ₹27,300 Lowest | 2,000 ₹30,000 | 6,000 ₹90,000 | 3,043 ₹45,645 |
| 9.00 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 1100 volts grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 9 | Each | 1,682 ₹15,138 Lowest | 1,760 ₹15,840 | 2,000 ₹18,000 | 3,500 ₹31,500 | 2,272 ₹20,448 |
Tender Value
₹50.0 L
EMD Value
₹99,900
Closing Date
3 Mar 2026, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
MAINTENANCE AND REPAIR TO DISTRIBUTION TRANSFORMER DEHYDRATION/TOPPING UP AND ATTENDING BREAKDOWN 24 HRS WITH OTHER MISC WORKS OF TRANSFORMERS AT OLD DOCKYARD MARINE SUBSTATIONS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2026_MES_751949_1
8463/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹500
GE (I) DM Visakhapatnam
₹99,900
Yes
17 Jun 2026
10 Feb 2026
5 Mar 2026
10 Feb 2026
3 Mar 2026
24 Feb 2026
11 Feb 2026 - 21 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Attending to transformer complain 24 hrs of capacity upto 1250 KVA tripping including meggaring of the cables and checking the physical condition of the transformer and assessing the physical condition and, checking oil level, conducting electrical LT testing like, measuring of IR values, ratio test, magnetic balance test, oil BDV test to assess the healthness of the windigs and if found statiafactory, then connections of the cable terminations and make arrange for charging the transformer.If transformer is found faulty, then recommend for the further repair/rewinding works to be carried out to put back the transformer into serviceall as specified and directed. | 30 | Each Job | - | - |
| 2 | All as per item No. 1.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 16 | Each Job | - | - |
| 3 | Overhauling of transformers of capacity upto 1250 KVA openning of top cover in situ or at wksp by unscrewing all nuts, bolts & washers, draining out transformer oil upto required level and keeping in clean container for repair/replacement of HT/LT bushings, tap changer, physical check of any defects, for lifting of core assy, for cleanning/repair and refixing top cover complete with RC 70 C rubberised cork sheet gusket sheet , existing/new nuts, bolts & washers for transformer indoor/outdoor type,The transformer to be put inside the hearting chamber for IR values imporvement, refilling of oil for transformer all as specified and directed.
Note:- (a) HT/LT bushings, Studs, tap changers, nuts, bolts & washers required new shall be mesured separately here-in-after (b) Silicon oil proof gusket shall be inclusive of quoted rate. (c) Transportation and loading and unloading charges to be measured and paid included. | 5 | Each Job | - | - |
| 4 | All as per item No. 1.00 above, but for transformer capacity 1500 KVA to 3000 KVA, 11/0.415 KV | 8 | Each Job | - | - |
| 5 | M & L for filtration/dehydration transformer oil of transformer voltage grade 11/0.415 KV, capacity 200 KVA to 3000 KVA indoor/outdoor type, floor mounted in situ till achieve dielectric strength minimum 40 KV at 4mm gap all as specified and directed. | 40,000 | Ltr | - | - |
| 6 | M & L for topping up/replacement of transformer oil with new transformer oil suitable for working voltage 11000 volts grade including necessary dehydration to achieve dielectric strength min 40 KV at 4mm gap complete all as specified and directed. | 4,200 | Ltr | - | - |
| 7 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 11 KV grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 12 | Each | - | - |
| 8 | All as per item No. 7.00 above, but for transformer capacity 1500 KVA to 2500 KVA, 11/0.415 KV | 15 | Each | - | - |
| 9 | Supply only transformer Epoxy bushing outdoor/indoor type suitable for 1100 volts grade complete of transformer capacity 500KVA to 1250 KVA, 11/0.415 KV transformer complete all as specified and directed. (Transformer bushings shall be compitable model with make and model of existing transformer) | 9 | Each | - | - |
| 10 | All as per item No. 9.00 above, but for transformer capacity 1500 KVA to 2500 KVA, 11/0.415 KV | 12 | Each | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.30 MB
Tendernotice_2.pdf
PDF • 0.30 MB
BOQ_842199.xls
BOQ • 0.45 MB
8463Tender.pdf
Tender Documents • 1.07 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .