Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.6 LAccepted-AOC | ₹25.6 L Quoted ₹25.8 L | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹26.1 L+₹33,828.76 (1.31%)Rejected-Finance PO BINNAGURI PS BANARHAT DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | ₹26.1 L+₹33,828.76 (1.31%) | L2 | Rejected-Finance OTHER THEN LOWEST BIDDER |
| 3 | L3₹26.3 L+₹56,119.24 (2.18%)Rejected-Finance | ₹26.3 L+₹56,119.24 (2.18%) | L3 | Rejected-Finance OTHER THEN LOWEST BIDDER |
| 4 | L4₹26.5 L+₹75,108.94 (2.91%)Rejected-Finance | ₹26.5 L+₹75,108.94 (2.91%) | L4 | Rejected-Finance OTHER THEN LOWEST BIDDER |
| 5 | L5₹27.0 L+₹1.2 L (4.71%)Rejected-Finance PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | ₹27.0 L+₹1.2 L (4.71%) | L5 | Rejected-Finance OTHER THEN LOWEST BIDDER |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
4 Dec 2021, 6:00 pmClosed
GE (SOUTH) BINNAGURI
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
SPL REPAIR OF ROOF TREATMENT AND SEEPAGE IN BLDG NO P-37 (LIVING ACCN) OF 195 MED REGT UNDER GE (S) BINNAGURI
2021_MES_488065_1
8469/E8
Open Tender
Civil Works
Item Rate
180 days
GE (SOUTH) BINNAGURI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (SOUTH) BINNAGURI
₹76,000
Yes
3 Feb 2022
13 Nov 2021
6 Dec 2021
13 Nov 2021
4 Dec 2021
27 Nov 2021
Amount
Demolition of brick masonary work, built in cement mortar including all quions, arches, pillars, etc. but excluding precast concrete articles etc. and deposited where directed complete all as specified and directed.
Demolition of cement concrete un reinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off the premises complete all as specified and as directed
Taking down chowkhats or frames with shutters (without talking off shutters from the freme) area n.exc 1.50 each and removing from site complete all as specified and directed.
Taking down and Refixing wooden shutters of any description exceeding 1 Sqm and not exceeding 2.0 Sqm each in the same opening , easing and adjusting including refixing builders hardware as required and renewal of unserviceable screws complete all as specified and directed.
Taking down cement or cement lime plaster any description from walls/ceiling etc including racking out joints, hacking for key & scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick, in cement mortar (1:3) on concrete/brick work of sunken portion, mixed with water proofing compound @ 200ml/50Kg of cement and fixed 40mm PVC pipe sport complete all as specified and directed.
M&L for Plain cement concrete (1:5:10), type E2, using 40mm graded stone aggregate in sunken floor surface finished fair and complete all as specified and as directed.
M&L for applying two coats of flexible polymer acrylic water proofing coating, 1mm thick (Dry film in two coats) using water proofing compound including necessary pond testing for 48 hrs in sunken portion complete all as specified and directed.
Providing plain cement concrete [1:2:4] type B0 using 12.5 mm graded aggregate 40mm average thickness as in sunken floor of wc/bath/toilet finished even and smooth without using extra cement mixed with water proofing compound @ 200ml/50kg of cement complete all as specified and as directed.
M&L for brick work with old size sub class 'B' bricks, straight or curved on plan exceeding 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F joint free non skid Ceramic tiles, coloured, superior quality 7 to 8mm thick (square/ rectangular) polished, area of each tiles exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
S&F joint free non skid Ceramic tiles, coloured, superior quality 7 to 8mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 300 x 200 x 7 mm thick on vertical surface such as dado / skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed.
S&F in repair factory made Z section steel ventilator with top hung shutter frame including projecting/ box type hinge with steel handle and steel peg stay complete with glazing bars , dovetailed or welded including a shop coat Red Oxide priming complete all as specified and directed.
S&F 4mm thick frosted glass, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed.
S&F factory made Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet, reinforced with MS square tube, supplying and fixing in opening with fittings as per specification & drawing complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain cover PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rails lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement and supply & fixing in the frame at site as per specification and shown on drawing SSR Part-II (2004) all as specified complete all as specified and directed.
S&F 100mm size stainless steel butt hinges medium weight complete all as specified and directed.
S&F 150mm long aluminum anodized barrel tower bolt of extruded section, fixed with screws complete all as specified and directed.
S&F 150mm size Aluminiun handle, oval type,Cast type, fixed with screws complete all as specified and directed.
S&F in repair vitreous china squatting pan of "Orissa" pattern size 580 x440mm white with integral foot rests including connection to trap and to flushing pipe anti syphonage pipe etc complete and making good to floor complete all as specified and directed.
S&F in repair of PVC low level syphonic action flushing cistern of 10 lit capacity including siphon, PVC float with ball valve, rubber cone and flush pipe,Brackets,32mm bore PVC connection pipe etc complete all as specified and directed.
S&F in repair Vitreous china wash basin, white, flat back, size 550 x 400 mm, including pair of brackets and cutting and pinning in ends of brackets,CP waste Coupling,32mm dia and 450 mm long Waste pipe, complete all as specified and directed.
S&F of pillar taps 15mm bore, fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe or for brass ferrule complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore complete all as specified and directed.
Taking up or down steel tubing and connections 20mm bore complete all as specified and directed.
S& F 15 mm bore steel water tubes, medium grade, galvanised with all fitings and fixed to wall, complete all as specified and directed.
S& F 20 mm bore steel water tubes, medium grade, galvanised with all fitings and fixed to wall, complete all as specified and directed.
S&F in repair stop valves fancy type cast copper alloy, chromium plated for 15mm bore pipe, screwed both ends including necessary fittings all complete as specified and as directed.
S & F in repair 15 mm dia bib tap cast copper alloy (fency type), chromium plated, with crutch or butterfly handle, screwed down for iron pipe or for brass ferrule all as specified and as directed.
S&F in repair of PVC Connection pipe 15mm size with PTMT nuts at both ends of length 450 mm complete all as specified and as directed.
S&F for Grating doom 100 mm dia with waste hole of PTMT fixed on floor/nahani trap with cement mortar, fixed in repairs complete all as specified and directed.
M&L for external rendering 20 mm thick in two layer, first layer shall be of 10 mm thick CM 1:6 and second layer of finishing coat shall be 10 mm thick in CM 1:4 mixed with WPC @ as per manufacturer instruction by weight of cement on brick work or concrete surfaces of wall and finished even and fair complete all as specified and directed. Note-WPC shall be measured and paid seperately.
M&L rendering 15 mm thick in cm 1:6 on fair faces of brick work or concrete surfaces finishing surfaces even and smooth without using extra cement , complete all as specified and as directed.
M&L rendering 5 mm thick in cm 1:3 on ceiling or concrete surfaces finishing surfaces even and fair complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer including cleaning glass, joinery,electrical fittings, wiring etc., of drops and splashes complete all as specified and directed.
M&L for preparing of newly plastered wall surface and applying two coats of Water thinable Oil emulsion Distemper over a coat of cement base putty including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed.
Material and labour for preparation of new plastered or unplastered surafces of ceiling and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed.
M&L for preparing of old plastered wall surface and applying two coats of Water thinable Oil emulsion Distemper including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed.
M&L for complete removal of existing treatmenton old decorated surfaces of wall and applying two coats of cement base paint over a coat of primer including cleaning glass, joinery,electrical fittings, wiring etc., of drops and splashes complete all as specified and directed.
Material and labour for preparation of old plastered or unplastered surafces of ceiling and applying one coat of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified and directed.
M&L for preparation of old steel and iron surface of any description, not otherwise described width or girth exc 10 cm and applying one coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old wood or wooden base materials of any description, not otherwise described over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to trenches, floor complete all as specified and directed.
S&F of PVC (SWR) bend any radius suitable for 110mm bore PVC pipe jointed with solvent complete all as specified and directed.
S&F in repair 75 mm bore PVC (SWR) pipe single socketed in any length with rubber ring joints, fixed to trenches, floor complete all as specified and directed.
S&F of PVC (SWR) bend any radius suitable for 75 mm bore PVC pipe jointed with solvent complete all as specified and directed.
M&L for 75mm thick plain cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) as in plinth protection and footpath finished even and smooth without using extra cement, including making joints to the full depth of PCC at every 3 metres and at every change of direction and filling the same with & including bitumen and sand 1:2 by weight complete all as specified and as directed.
Disconnecting existing PVC water tank including GI pipe inlet/outlet of any dia. Complete all as specified PVC tank having capacity exc. 250 ltr but not exc. 1000ltr setting aside (or lowering if required) and hoisting, reconnected old GI pipe with tank and refixing tank in same position complete all as specified and as directed.
Taking down existing tarfelt including plaster of any type and course from roof surface including adjoining parapets and removing the materials to a distance exc 50 mtr but n.exc 100 mtr away and deposited where directed including roughening old concrete surface by tucking and rubbing with wire brushes and cleaning the surfaces with water to remove all loose dirts etc complete all as specified and directed.
M&L for 15mm thick plastering in CM(1:4) using WPC as per manufacturer instrution by wt. of cement,in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane roof treatment complete all as specified and directed. Note:- WPC shall be measured and paid separately.
M&L for roof treatment with polymeric water proofing membrane to non accesible roof with the following courses as under complete all as specified :- (a) Cleaning surface by wire brushing,brooming, removing dust complete and make the surface even and smooth. (b) Applying a coat of bitumen primer conforming to IS-3384 - 1965 @ 0.40 lit/Sqm and allow to dry. (c) Applying one coat of hot blown bitumen grade 85/25 as per IS-702-1988 @ 1.20 Kg/Sqm of each coat applied over primer incl cleaning of surfaces . (d) Supply and laying 3mm thick polymeric water proofing membrane weight not less than 3.6 Kg/Sqm with nonwoven polyester fabric weight not less than 160 gms/sqm over area including overlapping of 100mm(min) as per manufacturers instruction.Polymeric membrane shall be taken to a height of 60cm (min) and then inserted inside the groove of parapet wall and shall be finished by a membrane flashing. (Note :- (i) Laying APP bassed polymenic membrane shall be done torch on methed or as per manufacturer's instructions. (ii) A minimum overlap of 100mm and 75mm should be made at the end and sides of the polymeric membrane respectively and sealed all overlaps and joints as per manufacturer's instruction. (e) Applying evenly one coat of bituminous aluminium paint @ 150 gm/Sqm complete all as specified and directed. NOTE: The complete work shall be done under strict supervision of manufacturers technical representative and as directed.
Supply only integral water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) area exc 1.50 and n.exc 4 Sqm each and removing from site complete all as specified and directed.
S&F pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete all as specified and directed. NOTE: The quoted unit rate under this item shall deemed to be include one shop coat of primer.
M&L for PCC 1:3:6 type C-2 (using 40mm graded aggregate) as in hold fast block including necessary form work etc complete all as specified and as directed.
S&F 30mm thick factory made Flush shutter, solid core construction, with block board core and plywood face panels, commercial type on both sidescomplete all as specified and directed.
S&F of 2nd class hardwood factory made 30 mm thick, glazed and skeleton door shutters, open rebated and prepated to receive glass gauze etc (with sash bars) edges of framing plain, chamfered or rounded materials and revated sash bars any number , edges of framing plain chemfered or rounded fitted with cut and mitred beads for securing glass in door etc or provided with styles and rails as specified in SSR part 1 section 8, clause 8.23 (a) and fitted to chowkats complete all as specified and directed .
S&F MS anodised barrel Tower Bolts of extruded section 200 mm long fixed with screws complete all as specified and directed.
S&F 150 mm long MS anodised, door handles of extruded section complete all as specified directed.
S&F 300mm long MS stove enamelled black finished, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections suitable for use with pad lock complete all as specified and directed.
S&F in repair factory made Z section steel window with side hung shutter frame including projecting/ box type hinge with steel handle and steel peg stay. complete with glazing bars , dovetailed or welded including a shop coat Red Oxide priming complete all as specified and directed.
S&F factory made Z section steel window with side hung shutter frame including projecting/ box type hinge with steel handle and steel peg stay. complete without glazing bars , dovetailed or welded including a shop coat Red Oxide priming complete all as specified and directed.
M&L mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed.
MESSRS SEN BROTHERS
M/s. RAMPHAL GARG
M/S SHYAM ENTERPRISE
L. B. SHARMA
S. G. CONSTRUCTION
P .BANERJEE AND CO
SG ENTERPRISE
M/S S.K. CONSTRUCTION
M/S East India Traders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .