Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹35.9 LAccepted-AOC | 1 | Accepted-AOC Accepted being the lowest tenderer | |
| 2 | 2₹44.0 L+₹7.5 L (20.7%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹46.0 L+₹9.5 L (26.1%)Rejected-Finance D NO 71 31 252 DURGANAGAR MALKAPURAM VISAKHAPATNAM 530011 | VISAKHAPATANAM | ANDHRA PRADESH | 530011 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹46.0 L+₹9.5 L (26.1%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹50.0 L+₹13.5 L (37.0%)Rejected-Finance DOOR NO 65 4 426 2 SANTHIGIRI COLONY GAJUWAKA POST GAJUWAKA VISAKHAPATNAM 530 026 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530026 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹47.4 L
EMD Value
₹94,800
Closing Date
10 Oct 2020, 6:00 pmClosed
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
GE (NB) Vizag, Nausenabaugh, Gandhigram Post, Visakhapatnam - 530005
AS AND AS TO 4TH FLR 45 AT INS PROVN OF RCC WALL WITH FENCING AND CNCTD WORK OVER DRAIN AT NSB AS AND AS TO RCC JALLI WALL FROM RAJPATH TO INS GATE AT NB AS AND AS TO FLOOR AND FALSE CEILING IN DCN NODE AND AS AND AS TO ROOF PARTICO T07 AT INS VIZAG
2020_MES_378726_1
C/8811/E8 TOKEN 49 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
As per Tender documents
9 documents required · 9 mandatory
₹500
GARRISON ENGINEER NAVAL BASE VISAKHAPATNAM
₹94,800
Yes
18 Dec 2020
18 Sept 2020
12 Oct 2020
18 Sept 2020
10 Oct 2020
3 Oct 2020
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish upto ouside MD land complete all as specified and directed.
M & L for Virified Ceramic tiles, 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm but not exceeding 0.42 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exc 0.11 sqm but n.exc 0.18 sqm, in floors etc, including 15 mm thick screed bed in cement mortor 1:6 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed, coloured, designer, ceramic, tiles, concept pattern of size (350mm x 250 mm/450mm x 350mm/300mmx450mm) x 6 to 7 mm thick, on vertical surfaces such as skirting, dados etc, including 10 mm thick bedding in cement mortor 1:4 and set & jointed in neat cement slurry & pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc.) any thickness including cover fillets complete all as specified and directed.
S & F GI frame work for suspended seamless false ceiling comprising of GI ultra perimeter channels of size 0.55 mm thick having one flange of 20 mm and another flange of 30 mm and a web of 27 mm alongwith perimeter of ceiling, screw fixed to brick wall/partition with the help of nylon sleeves and screws, at 610 mm centres. then suspending GI ultra intermidieate channels of size 45 mm, 0.9 mm thick with two flanges of 15 mm each from the soffit at 1220 mm centres with ultra ceiling angle of width 25mmx10mmx0.55 mm thick fixed to soffit with GI cleat and steel expansion fasteners. Ultra ceiling section of 0.55 mm thickness having knurled web of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm are then fixed to the ultra intermidieate channel with the help of connecting clips and in direction perpendicular to the ultra intermidieate channel at 457 mm centres including provn of 12 mm thick tapered edge Gypsum board (Confirming to IS-2095-1982) fixing with screw mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be jointed and finished so as to have a flush look which includes filling & finishing the tapered and square edges of the boards with jointing conmpound, paper tape and Preparing new plastered and applying two coats of distemper oil emulsion over a coat of alkali resisient primer over one or more coat of wall care putty including rubbing with sand paper to obtain a smooth surface complete all as specified and directed.
Taking up or down 15mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Taking up or down 20mm bore, Steel tubing and connections and keeping serviceable pipes in safe custody for reuse in the work after and including cleaning as directed.
Supply, laying, connection and testing, 15mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixed complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F in repairs, vitreous China wash basin, size 550 x 400mm, oval type white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed.
S & F in repairs, 15 mm bore, pillar taps, fancy type, cast copper alloy, chromium plated with capstan heads, screwed down high pressure with or without lettered 'Hot or Cold' with long screwed shanks and fly nuts, screwed for iron pipe complete all as specified and directed.
S & F in repairs, 15mm bore, PVC connection pipe 450mm long with PTMT nuts at both ends complete all as specified and directed.
Dismantling cast iron, PVC or reinforced concrete drain pipes, etc upto 110mm bore, with fittings jointed in cement mortar and taking out of trenches, floor or walls if required complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints fixed to wall, etc with all necessary fixing arrangement complete all as specified and directed.
S & F 110 mm bore, PVC (SWR), Soil waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, etc complete all as specified and directed.
S & F 75 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F 110 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 75 mm bore, PVC (SWR) bends of any radius complete all as specified and directed.
S & F 32 mm bore, PVC (SWR), Soil, waste and vent pipes, single socketed in any length with rubber ring joints fixed to walls, etc complete all as specified and directed.
S & F in repair 75 mm bore, PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F 15mm bore, bib taps, fancy type, with wall flange cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. CON-047KN or equivelant of make as per list of manufacturer)
S & F in repairs, 15mm bore, bib taps, two way, fancy type cast copper alloy, chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. FLR-5041N or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, angular stop cock with wall flange, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. (Make: Jaquar Cat No. KUP-35053PM or equivelant of make as per list of manufacturer)
S & F in repair 15 mm bore, Hand Shower (Health Faucet) with 8mm Dia, 1.2 Meter Long Flexible Tube & Wall Hook with all accessories complete all as specified and directed. (Make: Jaquar Cat No. ALD-573 or equivelant of make as per List of manufacturer's)
S & F Toilet Roll Holder, brass, chromium plated fixed to wall with brass screw complete all as specified and directed. (Make: Jaquar Cat No. AKP-35751P or equivelant of make as per List of manufacturer's)
S & F in repairs, Towel Rack 600mm long with Lower Hangers, Stainless Steel including Chromium plated brass screws and wooden/plastic cleats etc complete all as specified and directed. (Make: Jaquar Cat No. AKP-35781PS or equivelant of make as per list of manufacturer's)
S & F in repairs, vitreous China wash basin, size 550 x 400mm, white, flat back, with PVC waste pipe, CP waste coupling, chain, plug and porcelean stopper & backets including cutting for and pinning in ends of brackets but excluding tap complete all as specified and directed.
S & F in repairs Vitreous China Floor mounted coupled WC of Size: 380 x 660 x 765mm, Bowl for Coupled WC with UF soft close seat cover, Hinges, Fixing Accessories Set and Accessories Set, , P trap-180mm and Cistern with cistern fittings for complete set and all fittings and fixtures including connection to outgoing drain including making good damaged/disturbed surfaces complete all as specified and directed. (Make: Jaquar WC Cat No. LYS-WHT-38751P and cistern Cat No. LYS-WHT-38201 or equivelant of make as per list of manufacturer's)
Taking down wooden/aluminium chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) and re-fixing in the same opening after necessary re-alignment, repairs and re-sizing etc complete all as specified and directed.
Taking down aluminium partition complete and re-fixing in the same opening after laying of floor/wall tiles and necessary re-alignment, repairs and re-sizing etc complete all as specified and directed.
S & F 5 mm thick, sheet glass, ordinary quality and glazing with neoprene rubber beading for aluminium door/window etc in square exceeding 0.5 Sqm and n.exc 1Sqm in each pane complete all as specified and directed.
S & F Powder coated (minimum 50 micron) Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. (Note : (i) Thickness of aluminium section shall not be less than 1.5 mm).
S & F Powder coated (minimum 50 micron) Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. and anodised aluminium fittings such as peg stay 150mm long (01 No), hinge type B-21, 100mm long (02 Nos) and suitable size of handle complete all as specified and directed.
M & L for Preparation of old treated surfaces of any description over 10 cm girth or width not otherwise described after complete removal of existing treatment and painting with two coats of interior texture finish paint over a coat of primer over a layer of plaster of peris as per manufacturer's instructions complete all as specified and directed.
Demolition of brick work or stone / boulder masonry, built in cement mortar including all quoins, pillars etc stacking the serviceable bricks after removing mortar and cleaning for re-use and disposal of debris and rubbish to a distance n.exc 100m as directed by the Engr-in-Charge.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:4 using old size brick complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:4 on fair faces of brick masonry or concrete surfaces and finishing the surfaces even and fair without using extra cement complete all as specified and directed.
M & L for Precast reinforced cement concrete 1:2:4, type B-0 (using 12.5mm graded stone aggregate) louvres and jallies, 35mm thick including all mouldings and set in cement mortar 1:4 complete all as specified and directed.
M & L for preparation new external surfaces of wall, chajja, facia etc and applying two coats of water based acrylic weather proof exterior emulsion (exterior wall finish) paint over a coat of primer as per manufacturer's instruction complete all as specified and directed.
M & L for preparing newly plastered surfaces of walls, etc and applying three coats of white wash complete all as specified and directed.
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M & L Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in beams, cantilevers, lintels over 1.5m span complete all as specified and directed. (Note : Reinforcement will be measured & paid seperately)
S & F high strength corrosion resistant TMT steel bars 10 mm dia., and over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and directed.
S & F high strength corrosion resistantMild steel TMT bars 5mm dia and over upto and including 10mm dia in strirrups, spacers and binders spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips etc complete all as specified and directed.
M & L for use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etcetc complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated soils exc 1.5 Km but n. exc 5 Km and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
Demolition of un-reinforced cement concrete in ground floors and pavings n.exc 15cm thickness, (Below or above Ground level) and disposal of debris and rubbish to a distance upto outside MD land complete all as directed by the Engr-in-Charge
M & L for 25 mm thick, plain cement concrete 1:2:4, type B-0 (using 12.5 mm graded stone aggregate) as in sub-base of flooring, etc and finished the surface even and rough complete all as specified and directed.
Taking down chowkats or frames, exe 1.5 but n.exc. 4 Sqm in each with shutter (without taking off shutter from the frame) complete all as specified and directed.
S & F 10mm thick powder coated (minimum 50 micron) anodised aluminium grill, including jointing cleat and necessary fixing arrangement as required complete all as specified and directed. (Make: Deco Grill Model DG-102 or equivalent approved make)
M & L for preparing old plastered surfaces of walls by complete removal of existing treatment and applying two coats of distemper-oil-emulsion over a coat of chalk whitening over one or more coat of wall care putty complete all as specified and directed.
S & F Solar control film 25 micron reflective type sticked to glass panes as per instructions of manufacturers complete all as specified and as directed.
S & F Solid PVC wall linings consisting of 5mm thick plain colour PVC sheet inclusive of solvent cement and fixing at site for wall panelling inclusive of fixing on to wall to make PVC frame as per specification and as directed.
S & F 5mm thick PVC sheet fillet of width 35mm for wall panelling inclusive of fixing on wall to make PVC frame as per specification and directed
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as specified and directed
Dismantling Battens for tiles, shingles etc, of any size including tilting fillets, spaced n.exc 15cm complete all as specified and directed
S & F Pre-Painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
S & F Pre-Painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges/vally gutter, fixed with self tapping screws as per manufacturer's instruction complete all as specified and directed.
M & L for Rolled mild steel fo grade Fe 410-W (Gde-E- 250) quality-A as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section) including distance pices, cleat etc complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zine chrome primer complete all as specified and directed.
Excavating over areas, n exc 1.5 m deep and getting out in hard/dense soil complete all as specified and directed.
Excavation over areas, exc 1.5 m and n.exc 3.0m in depth and getting out in hard/dense soil complete as specified and directed.
Removing excavated soils exc 250 m but n. exc 500 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in foundations including rafts, footings, beams and mass concrete, etc complete all as specified and directed. (Note" Reinforcement will be measured and paid seperately)
M & L for Reinforced Cement Concrete M-30 (Design Mix) (using 20 mm graded stone aggregate) as in walls, retaining walls, ballast walls and the likes any thickness above top of footings including attached pilasters and buttreses complete all as specified and directed.
M & L for use & waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundations and plinth beams and similar work, vertical or to batter complete all as specified and directed.
M & L for use & waste Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter for flat rough finished surfaces of concrete complete all as specified and directed.
S & F Rolled mild steel work as in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) conforming to Fe-410-W (Gde-E-250) quality-B complete all as specified and directed.
S & F 1050 mm dia punched tape concertina coil as per IS 4454 with galvanised coating and punched tape material as per IS-513 deep drawn quality with galvanising coating , having medium barbs( barb length: 24+ 1 mm ,Pitch between two barbs 35+ 1mm ) fixed in position and secured to both sides of shaped angle iron post , stretched to a length of 6 to 8 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall fixed over angle iron ‘Y’ shaped, Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) to achieve 1050 mm dia as in fencing to steel post and to another coil /MS ribs including fixing with special galvanised fasterners such as 'J' clips , 'C' clips , U clips all as specified and directed (Note : After stretching the coil, the length of the compound wall on which it has been stretched shall be considered for measurement.)
S & F Galvanised 2 strand, steel barbed wire 2.24mm dia, barbed with 2 mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete as specified and directed. (Note : Each line of wire to be measured)
M & L for Broken glass coping on top of wall in 25mm layer of cement mortar (1:3) with a rounded or weathered finish and before the mortar has set, glass (of bottle or thick glass) broken to approximately 63mm gauge, shall be firmly embedded at the rate of 10 Kg of glass per square metre of rendered surface, jogged edges of the glass being left projecting complete all as specified and directed.
Point wiring with two runs of single core 1.5 Sq.mm. (Nominal area) PVC insulated unsheathed multistranded copper conductor cable FRLS (ISI marked) drawn through and including non metallic PVC conduit 20 mm bore medium grade (ISI marked) concealed / surface fitted type including Flush type metal GI boxes for fixing modular type / MS sunken box for conventional type switches, sockets, regulators etc. including provision of multistranded 1.5 Sq.mm copper conductor cable FRLS [ISI marked] as earth wire connected to common earth dolly and earth in distribution board complete all as specified and as directed, for one light/exhaust fan/fan point/call bell controlled by one way switch. (Note.: (i) The rate quoted is deemed to include making good the disturbed sufaces and to match the adjoining surface. (ii) The quoted rate is deemed to include cutting chases (if any) for concealed wiring including making good the same as per the existing one (iii) Modular white cover plate shall be measured and paid seperately)
S & F switch modular single pole one way 6 amp 240 volts,1 Module complete all as specified and as directed.
S & F Modular white cover plate with frame, but 6 module complete all as specified and as directed.
S & F in repairs recess mounted LED downlight of 1500 Lumens with all accessories internally prewired and including lamp and connecting up with twin core twisted copper conductor cable of suitable size complete all as specified and directed. (Make: Bajaj Cat No. 111612BZSLO 15W NW or equivelant of make as per list of manufacturer)
S & F in repairs LED tube light fittings, retro bar professional WH 5700K to 6000K and 2000 Lumens of cool white with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: Havell's Cat No. LUMILINEPLUSBS20WLED865SPCSS or equivelant of make as per list of manufacturer)
S & F Rigid non-metalic PVC conduit (20mmdia) exclusive of boxes (junction/ treminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hook etc. complete all as specified and directed.
S & F in repairs 2x2 recessed mounting slim panel light fittings, 3600 Lumens with all accessories, internally prewired and connecting up with twin core twisted copper conductor cable of suitable size including tube lamp complete all as specified and directed. (Make: CG Cat No. LSTP-36-CDL or equivelant of make as per list of manufacturer)
S & F in repairs LED 30 Watt street light luminaire, Pressure die cast aluminum housing, Heat resistant glass, IP65 protection, Better optics for uniform distribution with lamp and all accessories including mounting clamps, bolts, nuts and washers, 1.5 Sqmm weather proof 3 core FRLS grade copper conductor cable to fittings of suitable length complete all as specified and as directed. (Make: CG Cat No. LSTP-30-CDL or equivelant of make as per list of manufacturer)
M & L Sub main wiring with two runs of 2.5 sqmm (Nominal area) single core cable FRLS PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through including PVC conduits (Medium grade) of suitable size, fixed to wall/ceiling etc including 2.5 sqmm (nominal area) single core, FRLS PVC insulated, multistranded, unsheathed, copper conductor as earth wire and duly connected to common earth point complete all as specified and as directed by Engineer-in-charge. (Note : Conduits, two run cables and one run of earth wire will be measured as one length.)
S & F MCB SP 6 to 32 Amps, 240 Volts, B Curve, complete all as specified and as directed (Make : Indo Asian Cat part No. 811008 to 811015[ Optipro] or equivelant of make as perList of manufacturer's)
S & F Distribution Board, SPN 8 Way ,Double door with IP 54 protection including taking down existing fittings and fixtures and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. (Make : Indo Asian cat part No. 811826 [Optipro] or equivelant of make as perList of manufacturer's)
S & F Distribution Board, SPN 4 Way ,Double door with IP 54 protection including taking down existing fittings and fixtures and making good the disturbed surfaces to match with adjoining surface complete all as specified and as directed. (Make : Indo Asian cat part No. 811824 [Optipro] or equivelant of make as perList of manufacturer's)
S & F MCB SPN 40 Amps, 240 Volts, B Curve complete all as specified and as directed. (Make : Indo Asian Cat part No. 811035[ Optipro] or equivelant of make as perList of manufacturer's)
M & L for Earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level, connected to galvanized steel earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel, all as shown in Electrical Plate No 3 of SSR Part - I, including necessary excavation and earth work, P.C.C (1:3:6) type C-I with 50 mm thick Pre-cast R.C.C. (1:2:4) type B-I cover slab (reinforced with 8 mm dia deformed bar @ 15 cm C/C both ways and suitable handle of 10 mm dia round bar), including providing charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode, with funnel and 20 mm bore galvanized iron watering pipe (light grade), wire mesh, aluminium lugs, complete in all respect, GI earth wire protected by 15 mm bore (medium grade) galvanized iron pipe and other end connected with main switch board or Earthing test point as directed, including necessary earth work and disposal of spoil to a distance not exceeding 50 metre and necessary testing on completion complete all as specified and as directed by the Engineer-in-Charge.
Taking down unserviceable main switches, DBs, bus bars chambers including all fittings and fixtures such as MCBs, isolator, etc and removing from site complete all as specified and directed.
Taking down unserviceable sub-main wiring (any numbers of cable) with rigid steel conduits/PVC casing-caping including cutting chases for conduits and making good disturbed surfaces complete all as specified and directed.
P SRINIVASA RAO
SRI VENKATA SAI MANIKANTA CONSTRUCTIONS
K SATYANARAYANA ENTERPRISES
K K INFRA
G V N R CONSTRUCTIONS
D.CH.SURYA PRAKASH
Sri Vayuputra Constructions
S A R CONSTRUCTIONS
LEE INFRAS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .