Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹51.0 L+₹3.4 L (7.04%)Rejected-Finance 364 MAHAVEERPURAM BEHIND FUN WORLD CHOPASNI ROAD JODHPUR RAJ | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Not Lowest |
Tender Value
₹55 L
EMD Value
₹1.1 L
Closing Date
16 May 2022, 6:00 pmClosed
CWE AF JODHPUR
HQ CWE AF JODHPUR
85916 E8 Repair or Maint of Fire Alarm,Voltage Stabilizers,Cranes and other EM Assests and Repair or Maint of old Unserviciable LT Panel,Cable joints and Underground LT cable in Technical Area At Air Force Station Jodhpur
2022_MES_515069_2
85916/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF JODHPUR
As per Nit
7 documents required · 7 mandatory
₹1,000
GE AF JODHPUR
₹1.1 L
Yes
13 Jun 2022
27 Apr 2022
18 May 2022
27 Apr 2022
16 May 2022
4 May 2022
27 Apr 2022 - 28 Apr 2022
Amount
Repair or Maint of Fire Alarm, Voltage Stabilizers, Cranes and other EM Assets in Technical Area At Air Force Station Jodhpur (From BOQ serial item no-02 to 127)
S&F in replacement of 12 Volt 7AH maintenance free capicity battery suitable for automatic fire detection & alarm system complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of 12 Volt 36AH maintenance free capicity Battery suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of power supply/transformer/SMPS 24 V suitable conventional panel for Autocut Battery Charger complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of power supply/transformer/SMPS 24 Vsuitable addresseble fire alarm panel for Autocut Battery Charger complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Main Control Card (Mother Card) suitable for addresseble fire alarm panel Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Zone Card with complete IC suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of conventional type Photo Electric Smoke and heat Detector suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of multisenser Heat Detector & smoke detector ADDRESSIBLE TYPE suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Manual Call Point conventional type suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of addressible type Manual Call Point with extra key suitable for addressible type Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of conventional type Hooter capable to work on 24 DC Volt suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of addresseble type Hooter with indicator light capable to work on 24 DC Volt suitable foraddresseble Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Response Indicator (RI) suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Complete FIRE ALARM PANEL non addresseble type 4 zone suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Complete FIRE ALARM PANEL non addresseble type 8 zone suitable for Automatic Fire Detection & Alarm System complete all as specified and directed by Engineer-in-Charge.
M&L in maint rewiring of faulty area of fire alarm system zone wise with steel conduit and connected accessories including FRLS 1.5 sqmm wire 2 core used for rewiring complete all as specified and directed by Engineer-in-Charge.
M&L for general servicing of over head crane of capacity up to 2 Ton capacity (hand operated crane) with suitable T&P and replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections including greasing, gear box maintenece, chain pulley, color coating, crain rail allignment, chain replacement and all connecting items for fully operational cranes etc including load testing in presence of Engineer-in-Charge. Note :- Contractor shall rectify the problem within 4 days from receipt of complaint from engr-in-charge, panelty for not attending the complaint shall be 3% of quoted rate per day..
M&L in replacement of top lever with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of master lock with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of BEARING SET with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by the Engineer in charge.
M&L in replacement of loading chain for wheel of existing crane of suitable size with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of pull chain for wheel of existing crane of suitable size with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of steel side plate with suitable machanical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
Repair / maintenance of unserviceable electrically operated crane of capacity upto 2 Ton with suitable T&P and replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections, fully blocking of leakage of hydraullic oil etc, including load testing in presence of Engineer-in-Charge complete all as specified and directed by Engineer-in-Charge.
M&L in repair of EOT electric panel wiring including heavy duty contactor (upto 125A) , relay, fuse replacement with suitable electrical arrangement, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of EOT limit switch, suitable for crane capacity up to 2 Ton complete all as specified and directed by Engineer-in-Charge.
M&L in repair of EOT gear with suitable arrangement complete all as specified and directed by Engineer-in-Charge.
M&L in repair and general servicing of gear box suitable for 7.5 HP electric motor for both side hanger door including painting complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of gear box chain of suitable size as on site for for 7.5 HP electric motor for both side hanger door complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of 7.5 HP motor by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
M&L for rewinding of 10 HP motor by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
M&L for rewinding of 10 HP to 12.5 HP motor of jocky pump or mud pump by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
M&L for rewinding of 5 HP motor by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
Labour for unlowering/ taking down of submersible pump from bore well with column pipe 50 mm/80 mm dia, submersible cable from bore well by mechanical means for repaireing submerciable pump including lowering of submersible pump with column pipe and cable after repairing complete all as specified and directed by Engineer-in-Charge.
M&L for Rubbber gasket for column pipe of size 50/80 mm complete all as specified and directed by Engineer-in-Charge.
M&L for MS nuts and bolts complete all as specified and directed by Engineer-in-Charge.
M&L for rewinding of 7.5 HP to 12 HP summersible pump set by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying inclujding scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional includingreplacement ofworn out impellersand shaft etc to the entire satisfaction of the Engineer-in-Charge.
M&L for rewinding of 1 HP to 3 HP motor by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
M&L for rewinding of 7.5 HP to 12 HP fountain pump by opening the motor, taking out burnt out winding and rewinding of motor with super enamelled copper conductor of same gauge and size as per existing, varnishing, heat drying including scrappin of old paint & repainting with one coat of grey tinted synthetic enamel paint after motor is reassembled and tested and make it functional to the entire satisfaction of the Engineer-in-Charge.
Dismantling the WORM GEAR UNIT, Ratio 30:1 ,Model AU overhauling the same by repair/replacing the defective parts as ordered, cleaning varnishing and drying, re-erecting, aligning with the motor, testing and commissioning, any other minor parts required for proper functioning, painting the unit with two coat of synthetic enamel paint after preparing the surface and replacement of worn out nut bolts, stud of gland capacity including making over size complete all as directed by Engineer-in-Charge.(Location: 10 Sqn Taxi Track Gate).
M&L for General servicing of 100 HP centrifugal pump set and electric motor (only general servicing) , replacing bearing-02 Nos, , replacement of gland bush , unserviceable nut bolts and washers re-assembling with motor and testing complete all as specified and directed by Engineer-in-Charge.
M&L for General servicing of 75 HP to 100 HP diesal engine used in fire fighting including engine oil change, diesal and oil filter change,radiator cleaning,coolant chage ,air filter replacement,cleaning of diesal tank, general servicing of DG set self and testing complete all as specified and directed by Engineer-in-Charge.
M&L for General servicing of 75 HP centrifugal pump set with electric motor (only general servicing), replacing bearing-02 Nos, , replacement of gland bush , unserviceable nut bolts and washers re-assembling with motor and testing complete all as specified and directed by Engineer-in-Charge.
M&L for General servicing of 7.5 to 10 HP centrifugal pump set replacement of worn out impellers set with bronze impellers, replacing bearing, replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers re-assembling with motor and testing complete all as specified and directed by Engineer-in-Charge.
M&L for General servicing of 5 HP centrifugal pump set , replacing bearing replacement of worn out bearing housing, replacement of gland bush , unserviceable nut bolts and washers re-assembling with motor and testing complete all as specified and directed by Engineer-in-Charge.
S&F in repair DC electric motor gear box upto 2.5 HP capacity with megnatic coupling of electric motor, for both side hanger door complete etc complete all as specified and directed by Engineer-in-Charge.
General Servicing of hydaullic operated crane of capacity UPTO 1 Ton with suitable T&P and painting of crane replacement all connected deffective spare parts of crane and re-assembeling with necessary electric connections testing at LDP lab area,fully blocking of leakage of hydraullic oil etc complete all as specified and directed by Engineer-in-Charge and load testing in presence of Engineer-in-Charge.
S&F single pointed air termination aluminium rod 12mm dia 300mm long complete all as specified and directed by Engineer-in-Charge.
M&L for in repairs 40 mm bore galvanised steel tubing, light grade, 1.50 m long with MS plate welded as base for fixing of air termination rod including thrust block complete all as specified and directed by Engineer-in-Charge.
M&L for PCC block of any size made up of PCC 1:2:4 type B-1 Blocks for fixing/ mounting of running earthing conductor complete all as specified and directed by Engineer-in-Charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normalground level, connected to galvanised iron strip 32×6mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed by Engineer-in-Charge.
M&L in replacement for earthing complete with copper earth plate electrode 60cmx60cmx3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including copper earth strip 20x3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of soil, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe upto 7.5m complete all as specified and directed by Engineer-in-Charge.
M&L in replacment copper strip 20mmx3mm complete with,protection sleeves, saddles,separator and fixing screws at surrounding inside and outside the bldg complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of aluminium strip 25x3 mm complete with saddles and fixing screw for fitting the strip in replacement complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of cast iron sluice valve heavy duty class PN 1.6 flanged ends any pattern with head wheel and bras spindle ISI marked conforiming to IS 780 with jointing material flanged joint rubber gasket 6mm thick nuts ,MS nuts ,bolts ,washers ,rubber flange including taking out of existing unserviceable sluice valves complete all as specified and directed by Engineer-in-Charge. (a) 150 mm dia bore
(b) Ditto all as per above item no-55 but 100 mm dia bore complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of CI reflux valve of size 150mm dia bore with bypass arrangement complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Pressure switch Universal type AS complete all as specified and directed by Engineer-in-Charge.
M&L for repair of of 25 mm dia. Auto Air Purge valve and Drain valve for water piping complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of rubber coupling of pumping set 100 HP complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of rubber coupling of pumping set -75 HP complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of rubber coupling of pumping set -5/7.5 HP complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of water presuure gauge 0-7 kg / cm2 any type Make Febig or equivant suitable complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Indicating Light, 240V AC, LED Type Red, Yellow, Blue complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of ON/OFF Push Button complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of Timer GIC star/delta complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of star delta starter complete with all accessories for 5 HP capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of star delta starter compete with all accessories for 7.5 HP to 10 HP capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of auto star delta starter complete with all accessories for 15 HP capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of auto star delta starter complete with all accessories for 60 HP capacity complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of PVC copper cable of size 10sqmm, 3 core in flexible PVC pipe complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of PVC copper cable of size 60sqmm, 3 core in flexible PVC pipe complete all as specified and directed by Engineer-in-Charge.
M&L in replacment of 80mm cast iron foot valve screwed/ flanged complete all as specified and directed by Engineer-in-Charge.
M&L and General servicing and calliberation of automation panel works on pressure differential system for following electric driven disel driven pump set fire Fighting with complete testing of power supply cable including lug connection ,contactor trip circuit, measuring meter calliberation,No NC point cleaning,complete control wiring repair,relay and trip circuit ,maint and all connected accessories regarding serviceability of fire fighting system and testing of system in presence of Engineer-in-Charge.
S&F in replacement butterfly valve of 50MM size complete all as specified and directed by Engineer-in-Charge.
Labour charge for General servicing and routine check up of passenger lift of capacity of 5 person by manufacturer's Service Engineer/authorised channel partner's/OEM or any unserviceability of lift to ensure the serviceability of lift cosist of following Job:- (1) It will provide emergency services for breake down as and when required on priority basis. (2) User complain will be attended on priority basis. (3) time to time general check up of the lift during contract period. Note:- for servicing contractor will provide manufecturer service engineer for passenger lift and testing of the same under all circumstances in the presence of engineer in charge.Item cost is given beloow following:-
(a) Ditto all as per item no-77 but replacement of SMPS 24 V as existing on site complete all as specified and directed by Engineer-in-Charge.
(b)Ditto all as per item no-77 but replacement of SMPS 12 V as existing on site complete all as specified and directed by Engineer-in-Charge.
(c) Ditto all as per item no-77 but replacement of battery charger 48V as existing on site complete all as specified and directed by Engineer-in-Charge.
(d)Ditto all as per item no-77 but replacement of door sensor complete all as specified and directed by Engineer-in-Charge.
(e) Ditto all as per item no-77 but replacement of CVT transformer of 24V as existing on site complete all as specified and directed by Engineer-in-Charge.
(f) Ditto all as per item no-77 but replacement of limit switch as existing on site complete all as specified and directed by Engineer-in-Charge.
(g) Ditto all as per item no-77 but replacement of PBX system 3 line 1 outgoing complete all as specified and directed by Engineer-in-Charge.
(h) Ditto all as per item no-77 but replacement of heavy duty contactor used in lift upto 40A complete all as specified and directed by Engineer-in-Charge.
(j) Ditto all as per item no-77 but replacement of FLOOR sensor complete all as specified and directed by Engineer-in-Charge.
(k) Ditto all as per item no-77 but replacement of LIFT INDOOR LIGHT complete all as specified and directed by Engineer-in-Charge.
(l) Ditto all as per item no-77 but replacement of LIFT INDOOR EXHAUST FAN complete all as specified and directed by Engineer-in-Charge.
Labour charge for Gen/quartly servicing of Automated vertical storage & retrieval system (Lean lift) same to manufacturer's Service Engineer/authorised channel partner's/OEM of lean lift in the presence of Engineer-in-Charge.General servicing consist of following jobs:-(a)Mech maint are under:- (1)Retriever leval and allignment (2) Guide wheel allignment (3) checking of laoding runners oil (4) Pushers positioning user manual mode (5) checking of bolted joints (6) checking of chain tension (7) checking of breake adjustment (8) checking of gear box oil level (9) Lubrication of chains (b)Electrical Jobs are under:- (1) checking & cleaning of all contacts (2) checking of looser wire connection (3) checking of limit switches (c) Electronic Jobs are under:-checking and cleaning of all PCBs ,checking of sensors ,checking of relay functioning (d) Software Jobs are under:- upgradation in PLC programme and user interface
Incase of replacement of any above items no-89 the sch are given below:-(a) But replacement of NPN/PNP sensor
(b) Ditto all as per item no-89 above but replacement of megnatic sensor complete all as specified and directed by Engineer-in-Charge.
(c)Ditto all as per item no-89 above but replacement of UPS of 1 KVA capacity for lean lift complete all as specified and directed by Engineer-in-Charge.
(d) Ditto all as per item no-89 above but replacement of DS2 Area sensor Ht -844mm analog O/P Make:-Banner or equivellent
(e) Ditto all as per item no-89 above but replacement of Height curtain sensor PLCP1-780-A2-V1 complete all as specified and directed by Engineer-in-Charge.
(f) Ditto all as per item no-89 above but replacement of machanical spare part kit (pushers,bolts,tray moulds,rollers,main runners,loading runners,diamond chains,spockets,auto door sliding system etc )
General servicing of moving target shooting system including cleaing of movement rail ,polly cleaning and greasing ,servicing pf control panel cleaning of movement area of target etc complete all as specified and directed by Engineer-in-Charge.
M&L in maint rewinding of DC electric motor 1.5 HP geared motor used in moving target shooting system with same existing copper winding wire including replacement of bearing ,carbon bushes and all other accessories complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of limit switch used for rolling of wire rope over it complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of support pully of suitable size used for rolling of wire rope over it complete all as specified and directed by Engineer-in-Charge.
M&L in replacement of steel wire rope of 4mm size complete all as specified and directed by Engineer-in-Charge.
M&L in repair gear box used in EOT 02 ton capacity including replacement of worn out gear part as exisitng complete all as specified and directed by Engineer-in-Charge.
General Servicing and Repair to existing ELECRTONIC THYRISTOR MODULE or without thyristor module TYPE automatic / manual type APFC panel including painting of APFC Panel,cleaning of dust inside the panel from elect blower cleaning of controactors, relays junction points / connectors servicing overhauling of cooling fan complete testing of APFC relay including necessary setting with CTs load adjustment to match with replacement of U/S parts of capacity 5 KVAR to 200 KVAR to set the power factor in range between 0.96 to 0.990.complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement of contactor capacitor heavy duty type 3 pole AC of capcity having coil voltage 250 volt up to 10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement of contactor capacitor heavy duty type 3 pole AC of capcity having coil voltage 250 volt up to 25 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in Replacement of contactor capacitor duty type 3 pole AC of capcity having coil voltage 250 volt up to 40 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage for contactor type APFC panel Make : As exisitng complete all as specified and directed by Engineer-in-Charge.
Replacement of APFC relay/PLC source type with protection device intelligent automatic processor has on electric controller unit up to 12 stage for thyrister based panel panel Make : As exisitng complete all as specified and directed by Engineer-in-Charge.
Replacement of CT coil suitable for amp meter 100/5 amp ratio complete AE/ ENERCON/ EPCOS complete all as specified and directed by Engineer-in-Charge.
Replacement of CT coil suitable for amp meter 200/5 amp ratio complete AE/ ENERCON/ EPCOS complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt upto 10 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt ABOVE 10 KVAR and upto 20 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of existing ELECRTONIC THYRISTOR MODULE of each APFC PANEL 3 pole / 4 pole AC of capcity having coil voltage 250 volt above 20 KVAR upto 50 KVAR along with 1 No + 1 NC auxilary contact complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S capacitor 440 volts 50 HZ electric complete of capacity 10 KVAR (Bottle type ) gas filled complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 12.5 KVAR (Bottle type ) gas filled complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 15 KVAR (Bottle type ) gas filled complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 20 KVAR (Bottle type ) gas filled complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of U/S capacitor 440 volts 50 HZ electric to ULTRA HEAVY DUTY complete of capacity 25 KVAR (Bottle type ) gas filled complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item no-113 above but 7.5 KVAR complete all as specified and directed by Engineer-in-Charge.
Ditto all as per item no-113 above but 5 KVAR complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of SCRs used in thyrister switching suitable for 100 KVAR APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F in repairs of SMPS 220 V AC input and 24 V DC output and used in APFC panel complete all as specified and directed by Engineer-in-Charge.
S&F in replacement existing of U/S MCB TP 450 volts 10 KA 'C' curve type of capacity 32 amp complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of existing of U/S MCB TP 450 volts 10 KA 'C' curve type of capacity 63 amp complete all as specified and directed by Engineer-in-Charge.
M&L for repair / replacement of fountain water distribution chamber for 10 HP water pump complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of hose pipe of 40mm size used in fountain complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of anti vibrate pad mechanical pad consist of sandwinch housing specially design iron cashing and for protection of size 5X2 M16 complete all as specified and directed by Engineer-in-Charge.
M&L for replacement of anti vibrate pad mechanical pad consist of sandwinch housing specially design iron cashing and for protection of size 1X2 M12 complete all as specified and directed by Engineer-in-Charge.
Repair or Maint of old Unserviceable LT Panel, Cable joints and Underground LT cable in Technical Area At Air Force Station Jodhpur (From BOQ serial item no-129 to 198)
Disconnecting and taking out unserviceable current transformers of 200/5, 400/5 amps ratio of any description and supply, fixing, connecting, testing and commissioning of 200/5 to 400/5 Amps, test resin cast tap wound current transformer of rating 200/5 to 400/5 Amps on LT panel board and making connections of secondary terminals to ammeter with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Disconnecting and taking out unserviceable indication lamps and supply, fixing, connecting, testing and commissioning of indication lamps LED type with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using 1.5 Sqmm PVC insulated and sheathed copper conductor cable complete all as specified and directed by Engineer-in-Charge.
Taking down old unserviceable LT feeder pilar box and supply and fixing feeder pillar box out door type not less than 0.60 m X 0.60 m X 0.60 m made out of 3 mm thick CRCA sheet supported on angle iron frame 40X40X5 mm, aluminium bus bar 03 Nos rated capacity 400 Amps for phase and 01 No rated capacity 200 Amps for neutral and One 4 pole MCCB 250Amp and supported on porcelain insulator, powder coated and including PCC foundation complete all as specified & directed by Engineer-in -Charge.
Dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100 mm long medium weight mild steel butt hinges in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engineer-in-Charge.
Preparation of the old decorated existing external and internal steel surfaces of feeder pillar boxes/panels/ boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrapping or by blow lamps, applying necessary filler coat and stopping as required and applying two coats of synthetic enameled paint (grey in color) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 m deep and not exceeding 1.5 mtr wide and getting out including forming bottom surface to required levels/gradients/slopes for foundations/laying of cable etc including taking out existing cable protection brick cover complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed by Engineer-in-Charge.
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed by Engineer-in-Charge
Material & labour for stone slab 40 mm to 50 mm thick rough dressed Jodhpur stone patties/ slab cover in trenches for protection of cable 25 cm to 30 cm wide and not less than 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning complete all as specified and directed by the Engineer-in-Charge.
Supply,Laying, jointing and testing in replacement of XLPE LT Cable PVC insulated, armoured, heavy duty electric cable with aluminum conductor 1100 volts grade of any description and any make laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed by the Engineer-in-Charge for the following sizes :- (a) But LT aluminium conductor cable of size upto 10 Sqmm, 2 core
(b)Ditto all as per item no-141 but LT aluminium conductor cable of size upto 16 Sqmm, 2 core etc. complete all as specified and directed by the Engineer-in-Charge.
(c) Ditto all as per item no-141 but LT aluminium conductor cable of size upto 25 Sqmm, 4 core etc. complete all as specified and directed by the Engineer-in-Charge.
(d) Ditto all as per item no-141 but LT aluminium conductor cable of size upto 35 Sqmm, 4 core etc. complete all as specified and directed by the Engineer-in-Charge.
(e) Ditto all as per item no-141 but LT aluminium conductor cable of size upto 50 Sqmm, 4 core etc. complete all as specified and directed by the Engineer-in-Charge.
(f) Ditto all as per item no-141 but LT aluminium conductor cable of size over 70 Sqmm , 4 core etc. complete all as specified and directed by the Engineer-in-Charge.
(g) Ditto all as per item no-141 but LT aluminium conductor cable of size over 95 Sqmm , 3 ½ core etc. complete all as specified and directed by the Engineer-in-Charge.
(h) Ditto all as per item no-141 but LT aluminium conductor cable of size over 120 Sqmm , 3 ½ core etc. complete all as specified and directed by the Engineer-in-Charge.
(j) Ditto all as per item no-141 but LT aluminium conductor cable of size over 185 Sqmm , 3 ½ core etc. complete all as specified and directed by the Engineer-in-Charge.
Disconnecting & taking down old existing unserviceable MCCB of any description and in any position complete all as specified and directed by Engineer-in-Charge.
Supplying, fixing, testing and commissioning in repair MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu = 50 KA with adjustable load setting complete all as specified and directed by the Engineer-in-Charge.
S&F in repair MCCB, 400 Amps, four pole, 36 KA, 415 volt Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 250 Amps, four pole, 36 KA, 415 volt Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 200 Amps, four pole, 36 KA, 415 volt Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 160 Amps, four pole, 36 KA, 415 volt Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 100 Amps, three pole,16 KA, 415 volt Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
S&F in repair MCCB, 63 Amps, three pole,16 KA, 415 volt with Adjustable type complete all as specified and directed by the Engineer-in-Charge. Note: ICS = ICU 100%.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m deep below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete including taking out existing earthing all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Material & labour in repair for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20 mm X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m complete including taking out existing earthing all as specified and directed by the Engineer-in-Charge. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately.
Supplying and fixing in repair earth continuity conductor or main earthing lead 25mm x 3mm, alluminium strip/earth lead, laid in pipe/fixed on walls or any other position including jointing by tinned copper/brass nuts, bolts and washers and saddling ,welding at every joint complete all as specified and directed by the Engineer-in-Charge.
S&F in repair cable joint kit for 11 KV grade cable for straight through heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium cable of size 95 sqmm etc complete all as specified and directed.
M&L Boring of horizontal holes under road pavement,hard stansding by trenchess technology using boring machine all as directed as per Engineer-in- Charge.
Supply, install, testing and commissioning in repairs on load change over switch 100 Amps, four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning in repairs on load change over switch 125 Amps , four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning in repairs on load change over switch 200 Amps , four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning in repairs on load change over switch 320 Amps , four pole, 415V AC ,50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge
Supply, install, testing and commissioning in repairs on load change over switch 400 Amps, four pole, 415V AC, 50HZ etc in sheet metal enclosure complete all as specified and directed by Engr-in-charge
M&L in repair for plain cement concrete type C2 1:3:6 in 40mm graded aggregate for pole coping/foundation of panel/ hard standing complete as directed by Engineer-in-Charge.
Taking out Centrifugal pump type Make Kirloskar, RPM 1250, HP 10 from foundation by disconnecting suction & delivery pipe line, dismantling of pump, overhauling the same by repairing/replacing defective parts as ordered and reassembling, replacement of worn out nuts, bolts, repairing of bearing housing complete incl greasing and making connection complete all as directed.(Location: Near Blast Pen 34 & Near Blast Pen36).
(a) Ditto all as per item no-171 but Material only bronze impeller with neck ring complete all as directed.
(b) Ditto all as per item no-171 but Material only ball bearing DE + NDE complete all as directed.
(c) Ditto all as per item no-171 but Material only Gun Metal bush complete all as directed.
(d) Ditto all as per item no-171 but Material only MS gland cap complete all as directed.
(e) Ditto all as per item no-171 but Material only rubber bush/star coupling complete all as directed.
(f) Ditto all as per item no-171 but Material only MS coupling set with pin complete all as directed.
Taking out electric motor AC 3 phase 415 volts from foundation, taken to work shop, dismantling the motor, taking out old burnt wiring, cleaning the starter slots, material and labour for rewinding the stator with appropriate gauge super enameled copper wire and installation paper, sleeves, thimbles etc, complete varnishing and backing up the windings, repairs to bearing housings, replacing the bearings, cooling fan and connection plate, taking back to site, fixing on foundation making electric connection, realigning with pump and testing etc complete all as specified and directed of following size :- (a) 7.5 HP Cap.(Location: Near Blast Pen 32 to 38).
S&F in repair aluminium cable lugs of size 10 sq mm to 25 sq mm etc complete all as specified and directed.
S&F in repair aluminium cable lugs of size 25 sq mm to 50 sq mm etc complete all as specified and directed.
S&F in repair aluminium cable lugs of size 70 sq mm to 150 sq mm etc complete all as specified and directed.
S&F in repair aluminium cable lugs of size 185 sq mm to 240 sq mmetc complete all as specified and directed.
S&F in repair aluminium cable lugs of size 240 sq mm to 400 sq mm etc complete all as specified and directed.
S&F in repair aluminium cable lugs of size 500 sq mm to 630 sq mm etc complete all as specified and directed.
M&L for stay assembly complete with accessories as shown in electric plate No.I including loop type insulator, stay clamps, stay wire, PCC and excavation etc complete all as specified & directed with diameter of stay 20 mm of stay rod etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 25 sq mm to 50 sqmm etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 70 sqmm to 95 sq mm etc complete all as specified and directed
S&F in repairs 1.1 KV straight through joint kit 3.5 core 120 sqmm to 150 sq mm etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 150 sq mm to 185 sqmm etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 240 sq mm to 300 sqmm etc complete all as specified and directed.
S&F in repairs 1.1 KV straight through joint kit 3.5 core 400 sq mm etc complete all as specified and directed.
S&F in replacement GI tubing light grade 80 mm dia for /pole cable protection including fixing clamp, nut bolt washer complete accssories etc complete all as specified and directed..
S&F in replacement GI tubing light grade 50 mm dia for /pole cable protection including fixing clamp, nut bolt washer complete accssories etc complete all as specified and directed.
M&L of checking of HT 11/33KV cable of any size by means of HT Cable Fault Locator Machine by requisition for removal of HT cable faults etc complete all as specified and directed.
S&F in replacement Danger notice plate of 1.6 mm thick mild steel sheet,vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S Clamps, bolts and nuts of size 20 x 15 cm etc complete all as specified and directed.
M&L in replacement cross arms, bracing, supports, clamps and back plates fabricated from structual steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts in any shape or size as indicted and inclusive of one primer coat one under coat and two finishing coat of aluminium paint etc complete all as specified and directed.
Supplying and laying in replacement synthetic Rubber insulated mats 2.5 mm thick for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed.
Surface cleaning/site clearance n exc 15 cm in depth in Sub stations area, trenches,sub station rooms, two pole/ four pole structure surroundings to make a over all presentable condition all as directed by Engineer-in-Charge.
M/s. Dhananjay Construction
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .