Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC | ₹29.5 L Quoted ₹29.9 L | L1 | Accepted-AOC Being Lowest Bid |
| 2 | L 2₹31.6 L+₹1.7 L (5.75%)Rejected-Finance | ₹31.6 L+₹1.7 L (5.75%) | L 2 | Rejected-Finance Higher Side |
| 3 | L3₹31.8 L+₹2.0 L (6.54%)Rejected-Finance VILL KASHNI NEAR AANCHAL DAIRY PO BIN PITHORAGARH UTTARAKHAND PIN 262508 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262508 | ₹31.8 L+₹2.0 L (6.54%) | L3 | Rejected-Finance Higher Side |
| 4 | L4₹36.9 L+₹7.0 L (23.6%)Rejected-Finance CANTT ROAD KASHNI BIN PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262520 | ₹36.9 L+₹7.0 L (23.6%) | L4 | Rejected-Finance Higher Side |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
25 May 2020, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post Bharkatia Pithoragarh ( UK)PIN-262520
COMPREHENSIVE REPAIR / REPLACEMENT OF SPARE PARTS SOLAR WATER HEATER 100 / 200 LTR CAP AND STP PLANT-02NOS OF CAP 900CUM PER DAY ALONG INCLUDING ALLIED ELECTRICAL WORKS AND WATER SUPPLY WORKS AT MIL STN PITHORAGARH
2020_MES_341357_1
8283/PGH/E8
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Pithoragarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹64,000
Yes
22 Jul 2020
28 Apr 2020
27 May 2020
28 Apr 2020
25 May 2020
12 May 2020
28 Apr 2020 - 12 May 2020
Amount
DESCRIPTION OF ITEMS
Attending daily complaints of area by deputing adequate number of teams of qualified Electrician and helper for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system by replacing the U/S items such as switches, replacement of fuse wires, distribution boards, MCB light / power, lamp holders, bracket / pendent / batten, bell / buzzer, push button, ceiling rose, capacitors and other similar electrical items/fittings etc to make functional of light / fan / bell point, light & powerplug, including provisioning of small pieces of electricals cables PVC insulated copper multistranded conductor of sizes1.5 Sqmm to 10 Sqmm single core and length not increasing 0.50 mtrs and other minor items of cost not more than Rs. 10/- complete all as specified and directed by Engineer-in-Charge. Notes:- (a) Replacement of electrical accessories, if required shall be measured and paid separetely in relevant items. Unserviceable items retrived form complaints shall be abstracted under sch of credit. (b) The fault shall be attended within one day, otherwise recovery shall be charged Rs. 50/- per complaint per day. (c) Electrician shall obtain the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments.
Supply only ceiling fan regulator electronic stepped type operating on 230V,
Supply only ceiling rose two or three terminal operating on 230V, 50Hz
Supply only switch piano one way 5 Amps 240 Volts
Supply only Switch piano, flush type, 15 Amps single pole, one way
Supply only Socket out let 2 in 1, 3 pin, 5 and 15 amps, flush type
Supply only of Socket out let 2 in 1, 3 pin, 5 amps, flush type
Supply only Bell push flush type 5 Amps
Supply only Bell electric AC 230 V, Single phase with battary back up, 50 C/S
Supply only electronic choke suitable for 36/40 watts FTL fittings
Supply only Flourecent Tube light lamps T5 of 36 Watts Make : CG/ PHILIPS / BAJAJ/WIPRO
Supply only11 W ballast of CFL fitting. Make:-CG/BAJAJ/PHILIPS
Supply only CFL 11 W , 2/4pin type 230 V
Supply only MCB SP 5-32 Amps capacity
Supply only MCB SPN of 40Amps capacity
Supply only isolator 4 pole 100 Amps 415 Volts
Supply only MCB TPN 40 to 63 Amps 415 Volts
Checking of fault in Solar water Heater of area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items like screw, insulation Taps, flexible twin core cable upto 1 mtr approx or any electrical accessories of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified and directed by Engineer-in-Charge. (a) Replacement of solar heater items, if required shall be measured and paid separetely in relevant items. Unserviceable items retrived form complaints shall be abstracted under sch of credit. (b) The fault shall be attended within one day, otherwise recovery shall be charged Rs. 50/- per complaint per day. (c) Electrician and plumber shall obtain the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments.
Supply only Hot water tank SS 304 ex model with heat exchanger
Supply only Heating element 2 KW
Supply only Heating element 3 KW
Supply onlyThermostat for solar water heater 100/200 Ltr
Supply only EIS-DA (descaling chemical for all type metal)
Supply only Temperature guage for solar water heater 100/200 Ltr
Supply only Toughened Glass for solar water heater 100/200 Ltr
Supply only Makeup tank for solar water heater 100/200 Ltr
Supply only NRV of makeup tank for solar water heater 100/200 Ltr
Supply only Elbow 15mm
Supply only Elbow 20mm
Supply only Elbow 25mm
Supply only Tee 15mm
Supply only Tee 20mm
Supply only Tee 25mm
Supply only Socket 15 mm
Supply only Socket 20 mm
Supply only Socket 25 mm
Supply only Union 15mm
Supply only Union 20mm
Supply only Union 25mm
Supply only Reducer elbow 20mm
Supply only Reducer elbow 25mm
Supply only Reducer Tee 20mm
Supply only Reducer Tee 25mm
Supply only Reducer Socket 20 mm
Supply only Reducer Socket 25 mm
Supply only of Hex nipple 15 mm
Supply only Hex nipple 20 mm
Supply only Hex nipple 25 mm
Supply only Tank nipple 15 mm
Supply only Tank nipple 20 mm
Supply only Tank nipple 25 mm
Supply only Plug 15mm
Supply only Plug 20mm
Supply only Plug 25mm
Supply only Nipple 15 mm
Supply only Nipple 20 mm
Supply only Nipple 25 mm
Supply only Ball valve 15mm
Supply only Ball valve 20mm
Supply only Ball valve 25mm
Supply only GI pipe medium grade 15 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 20 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 25 mm, ISI marked all as speficied and directed
Supply only clamps as per sample
Supply only flexible hose pipe 20 mm as per sample
Supply only gasket as per sample
Supply only of M-Seal
Supply only float valve 20 mm
Supply only float valve 25 mm
Supply only Tank lid 200 ltrs
Supply only of Tank lid 500 ltrs
M & L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on complete copper tubing in solar water heater and after completion of job reassembling the same complete all as specified and directed
Dismantling exisiting solar water heater and descaling the pipe by means of descaling agent the same after reassembling after comletion the work. Note : Descaling agent shall be paid and measured separetely
M & L for painting of solar water heater and MS stand with mokey case of tank duly painted with one coat of synthetic black enemaled paint complete all as specified and directed
Disconnecting existing over head water storage tanks capacity n exc 200 Ltrs for cleaning and removing all scale and dirt, etc, from tanks and from mouth of circulating pipes, etc and reconnecting and including one coat synthetic enamel paint on tank of size 450mmx300mm and writing letters ("CLD ON MM-YY") of height 7.5cm complete all as specified and as directed. Note : Cleaning of tank should be done carefully by means no float valve broken or no leakage remains after cleaning.
S & F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) in white colour, hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge
Taking down unserviceable PVC / metallic Exhaust fans up to 300mm sweep dismantling, overhauling, and replace the unserviceble spares parts including reassembling/refixing back in the same location, including with cord flexible copper conductor connections after completion of repairs, including testing complete all as directed . Note: Spare parts and motor winding shall be measured and paid separately under relevant items.
M & L for rewinding of fan motor of any make up to 300mm sweep of exhaust fan with super enameled copper wire of same guage / type, varnishing including removal of existing burnt winding carefully from slots, cleaning the slots with cleaning agents complete all as directed.
Supply only ball bearings suitable for any type of fan/exhaust fan and testing complete all as directed . Make-NBF/NBC/TATA
Supply only Capacitor of 2.5 mfd complete all as directed by Engr-in-Charge.
S & F in replacement of LED Integrated Batten T5 box type surface mouted, 1x18 Watt prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed. Make :- Bajaj/Philips/Havells
S&F in replacement of 5w decorative ultra slim linear LED lighting fixture with extruded Al. heat sink, environmental friendly, energy efficient complete all as specified and directed. Make : Bajaj/Philips/Havells
S&F in replacement of PVC type exhaust fans, AC single phase, 1400 RPM, 230/240 V of size 250 mm sweep complete all as specified and directed. Make-Bajaj/Havells Cat No: Turboforce
M & L in replacement of sub main wiring complete with 2 runs of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor and drawing through surface and including PVC conduit of appropriate size and connecting terminal ends including provision of 1 run of 4 Sqmm PVC insulated heavy duty and unsheathed cable with multistranded copper conductor for earth continuity conductor and connecting to earth dolly including taking down old unserviceable wiring complete all as directed .
All as per above item No 84 above here-in-before with 2 runs of 6 sqmm and 1 run of 6 sqmm earth wire complete all as directed.
S & F in replacement of Vertical type TPN DB, 4 Way, as per IS-8623, IP-42, double door, protection, universal mounting with 100A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps TPN as incomer and MCB TP as outgoing, with and including providing following MCCB/MCBs & making necessary electrical connection for incoming & outgoing cables, with copper lugs, crimped with crimping tool :- a) Incoming:- MCCB, TPN, 415 Volts,125 Amp ultimate breaking capacity (lcu)-25 KA, confirm to IEC-60947-2-01 No (b) Out going MCBs:- MCB TP 415 volts 63 Amps having repturing capacity 10 kA, 'C' curve type-4 Nos
Supply and Fix in replacement installation and testing of electric temper proof energy meter, ISI marked , single phase 230 volts 2 wire , 10-60 Amp with optical port facility including sealing the meter with sealing wire and sealing bits, Accuaracy - class 1.0 as per IS 13779/IEC 61036 complete all as specified and directed.
S & F in replacement of MCCB 100 Amp 35 KA 4 pole 415 V complete incuding taking down old existing unserviceable complete all as specified and directed.
Supply and laying in replacement of high voltage insulation mat (blue in colour) made of elastomeric polymers material having a high insulation resistance, thus imparting total safety of human being from any leakage current, having high insulation resistance of class B of size 2.5 mm thick and 1.0 m width LT grade confirming to IS - 15652 : 2006, including pasting of mat with SR-998 by adding thinner as per requirement complete all as specified and directed. Make- Jyoti / Electrosafe / Vardhman
Material and Labour for opening up the motor 25/30 HP carefully and removing burnt windings from stator and rewinding with suitable gauge of supper enamelled copper insulated wire and superior insulating material including varnishing, heating, greasing replacement of worn out bearing, reassembling the same,including testing on full load up to entire satisfaction, complete all as directed
Disconnecting old unsv and S&F in replacement in trenches, under floor or fixed to walls XLPE insulated cable, screened PVC bedded, galvanised steel strip or wire armoured, electric power cable heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sq mm 3.5 Core complete all as specified and directed.
All as per item No 91 but size 35 Sqmm
All as per item No 91 but size 50 Sqmm
All as per item No 91 but size 95 Sqmm
Comprehensive maintenance for repair by periodical (monthly) checking of Motor, Compressor system, Motorized Valve, STP pipe line, filter system, pressure guage including air compressor complete coupling & leakage joint and repair/ replacement of worn out parts of Sewage treatment Plant 900 KLD capacity -02 Nos Note :-(i) Technician should attend break down on as and when required to rectify the defects urgenlty. (ii) Defective parts shall be measured and paid separetely.
S&F in replacement of fan belt for compressor/flaculator motor any size and any type as per sample
S&F in replacement of Butterfly valve 150mm nominal bore, cast iron body with complete nut & bolts Butterfly valves shall conform to BS:5155, MSS SP 67 & APT 609 and designed to fit without gaskets between mating flanges complete all as specified and directed.
S&F in replacement of Butterfly valve 125mm nominal bore, cast iron body with complete nut & bolts Butterfly valves shall conform to BS:5155, MSS SP 67 & APT 609 and designed to fit without gaskets between mating flanges complete all as specified and directed.
S&F in replacement of NRV 150mm of cast iron body and shall conforrming to IS 5312-(Part 2) -1986 with complete nut & bolts complete all as specified and directed.
S&F in replacement of pressure guage/ Rotometer/Flow indicator as per sample for STP
Material and Labour for taking out/down Pump/motor from base/chamber and opening up the motor 75 HP carefully and removing burnt windings from stator and rewinding with suitable gauge of supper enamelled copper insulated wire and superior insulating material including varnishing, heating, greasing replacement of worn out bearing, reassembling the same,including testing on full load up to entire satisfaction, complete all as directed.
All as per Item No 101 above but 25 HP (blower motor)
All as per Item No 101 above but 7.5 HP wash out motor
All as per Item No 101 above but 3.5 HP submersible pump
M & L for taking out and Cleaning of BAR screen chamber / Oil and grease Trap / Equvalisation tank / MBBR Tank / Flocculator Tank / Tube Settler Tank / Chlorine contact tank / Filter Feed Tank / Treated water Tank, dewatering and degging out sluge, mud state and removing sludge to a distance exc. 250m and n exc. 500m and disposed off as directed by Engr-in-charge Note- (i) Rates are deemed include for Transportation & labour charges from STP to low laying area as directed. (ii) Cleaning of sludge shall be carried out 2 times with interval of three months; each cleaning shall be measured as Each Job.
M & L taking out and cleaning sludge drying bed of STP any size degging out sluge, mud state and removing sludge to a distance exc. 250m and n exc. 500m and disposed off as directed by Engr-in-charge Note- (i) Rate of Transport & labour included for disposing material as directed. (ii) Cleaning of STP shall be carried out 2 times with interval of three months; each cleaning shall be measured as Each Job.
M & L for preparation of old painted surface with paint remover, scrapper & fine ambery paper and painting with one coat of heat resistance paint on 75 HP Centrifugal pump set including motor, and writing SM No/ Maching No and connect back all Electrical connection and testing complete all as specified and directed.
All as per Item No 107 above but compressor unit & LT Panel- 03 Nos complete
All as per Item No 107 above but Filter unit-02 Nos with pumps -02 Nos complete
M&L for applying one coat of synthetic enamel paint including preparation of old painted steel surfaces (panels, pipe lines, chequared plates) of any description over 10 cm width or girth as specified and directed.
Dismantling, Repairing and servicing of chemical injecting pump with complete serviceable condition all as directed by Engr In Charge
S&F in replacement Chemical injection pipe as per sample
S&F in replacement Contactor 160 Amp 415 Volts ML12 AC 50Hz (Make- L&T/Havells/Legrand)
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 M. deep for foundation or for laying of pipes etc and getting out in hard/dense soil, comlete all as specified and directed
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm in soft/loose soil, complete all as specified and directed
Removing excavated soil to a distance exceeding 50m but not exceeding 250 m and depositing where directed at a level not exceeding 1.5 m above the starting point , complete all as specified and directed.
Supply and spreading of clean dry river sand in trenches/ transformer yard/ two pole structure yard for cable protection complete all as directed Note:- Punned thickness only shall be measured for payment purpose.
M&L for laying common burnt bricks, sub class 'B', of size 230 x 115 x 75 mm in trenches for cable protection complete all as directed by Engr-in-charge.
Cutting the road to 60cm depth and 45cm wide for laying cable and making good the disturbed / excavated ground by filling the excavated material and top 300 mm by filling with PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) to match with level of road complete all as directed
M & L Galvanised iron tubing 40 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
kumaon and hills strument engnering services
M/s J P Traders
m/s vishnu kumar agarwal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .