Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance HARIBHAVAN NORTH ARIYAD P O ALAPPUZHA | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance LSGD DIVISION ALAPPUZHA | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹98,221
EMD Value
₹2,456
Closing Date
5 Mar 2025, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
MUNICIPAL ENGINEER
Office of the Executive Engineer, LSGD, Alappuzha Municipality,
GENERAL-Shifting mini mast amp 10 mtr. in YMCA jn. and Kaichoondy Jn. in Alappuhza -under Alappuzha Municipality.-General Electrical Work
2025_LSGD_741704_1
EL/8302/ME/LSGD/AMC/25
Open Tender
Electrical Works
Item Rate
60 days
ALAPPUZHA MUNICIPALITY
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹2,456
Yes
6 Mar 2025
22 Feb 2025
6 Mar 2025
22 Feb 2025
5 Mar 2025
22 Feb 2025
Amount
Electrification
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.13:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 4.00 sq mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
90.12.1.2:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 6 sq mm
90.12.7.2:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.2 core 6 sq mm with factory made clamp
9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm)
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
OD391701/2024-2025:Supply & providing 25x6 mm brass bolt , nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.
OD391700/2024-2025:Supply & providing 12x3 mm brass bolt & nut with washers on the existing MS box/earth bus etc. as required including drilling holes as required.
OD391707/2024-2025:Earthing with 40 mm dia. medium class GI earth pipe 2.5 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)
OD391708/2024-2025:Supply & fixing 32A ,fuse unit with suitable size HRC fuse in the existing board and giving connection as required.
OD391705/2024-2025:Charges for preparation of KSEB single phase service connection documents for availing single phase connection & producing to consumer.
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD391703/2024-2025:Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel .
OD391702/2024-2025:Supply & laying ,jointing of DWC pipe 40/32 mm in the existing trench for protection of UG cable.
OD391704/2024-2025:Supply & fabricating suitable size support made out of 35x35x5 mm or nearest size angle iron as required including painting as required.
OD391706/2024-2025:Supply & providing 4 nos, 20x 750mm or nearest size GI foundation bolt with washers in position at the time of foundation concreting as required.
OD391713/2024-2025:Supply & providing 6 nos, 20x 750mm or nearest size GI foundation bolt with washers in position at the time of foundation concreting as required.
OD391699/2024-2025:Charges for Dismantling the existing 9mtr. mini mast with 6 nos 150w LED flood light fitting & metal meter box with accessories conveying to new place by lorry, loading and unloading , erection of 9 mtr. octoganal mini mast pole with LED & meter box to new place erected in position using crane /fork lift as required. excluding concrete.
OD391711/2024-2025:Charges for Dismantling the existing 10mtr. motorized mini mast with 6 nos 150w LED flood light fitting & with accessories conveying to new place by lorry, loading and unloading , erection of 10 mtr. octoganal mast pole with LED to new place erected in position using crane /fork lift as required. excluding concrete.
OD391712/2024-2025:Supply & renewal of 32A single phase contactor in place of damaged ones.
OD391709/2024-2025:Supply & renewal of 240v, AC timer ,DIN base mounting type ( L & T. J 648B1-analog version ) on existing enclosure and giving connection.
OD391710/2024-2025:Supply & installation of dust & vermin proof wall mounting meterbox (450x375x200 mm) sintex make (GSMB- 4537) with base plate suitable to fix energy meter,cut outs ,NL etc. on wall using suitable nut ,bolt etc.
PHILIPOSE JOSEPH (BID ID -2139742)
Bidder Name
HARISH AND CO
PHILIPOSE JOSEPH
stage.html
html • 0.02 MB
finance_1193277.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .