Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹48.6 LAdmitted-Finance HIMALAYA HOUSE D 248 SECTOR 10 NOIDA DIST G B NAGAR U P 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | -1.40% | ₹48.6 L | L1 | Admitted-Finance |
| 2 | L2₹49.1 LAdmitted-Finance | -0.50% | ₹49.1 L | L2 | Admitted-Finance |
| 3 | L3₹50.8 LAdmitted-Finance | +2.99% | ₹50.8 L | L3 | Admitted-Finance |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical | - | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹49.3 L
EMD Value
₹98,700
Closing Date
24 Mar 2026, 5:00 pmClosed
Sr Manager E/M-III
Noida Authority Office Sector 39 Noida
M/o Authority Building (Annual Operation and maint. of 33/11 kv sub station in Sector -96, Noida)
2026_NOIDA_1123337_1
17/GM(E/M)/SM.(E and M)-III/2025-26
Open Tender
Electrical Works
365 days
Noida
Please refer to tender document
3 documents required · 3 mandatory
₹2,124
Noida
₹98,700
20 Apr 2026
11 Mar 2026
25 Mar 2026
11 Mar 2026
24 Mar 2026
11 Mar 2026
CAPABILITY STATEMENT
*It is compasury for the bidder to fill this statement and the bidder must upload only those documents that support this statement.
Job No.- 17/GM(E&M)-/S.M,E/M-3/2025-26
Tender- M/o Authority Building (Annual Operation and maint. of 33/11 kv sub station in Sector -96, Noida)
Name of Tenderer
TOTAL NIT COST OF PROJECT (In Rs.) 4932183
S. NO. ELIGIBILITY CRITERIA (Value To Be Filled By the Tenderer In Indian Rs.) Status FINAL STATUS QUALIFIED
1 SOLVENCY (Issued within a period of minimum six months). 40% OF TOTAL ESTIMATED COST NOT QUALIFIED NOT QUALIFIED
2 EXPERIENCE (WITH GOVERNMENT/SEMI- GOVERNEMTN/ PSUs ONLY) completed works during the last 7 years ending last day of the month previous to the one in which applications are invited Three similar completed works each costing not less than the amount equal to 40% of estimated cost put to tender NOT QUALIFIED
Two similar completed works each costing not less than the amount equal to 60% of estimated cost put to tender NOT QUALIFIED NOT QUALIFIED
One similar completed works costing not less than the amount equal to 80% of estimated cost put to tender NOT QUALIFIED NOT QUALIFIED
RESULT OF EXPERIENCE NOT QUALIFIED
3 TURNOVER (During the immediate LAST 3 consecutive financial years)
Average annual financial turnover on construction works should be atleast 30% of the estimate cost during the immediate last 3 consecutive financial years
4 Required technical staff *The bidder must submit the supporting document as per prequalification on stamp paper with notary
5 Required machinery * The bidder must submit the supporting on stamp paper with notary
6 Character Certificate of Indivisual /Partners/directors issued from District Megistrate B11
7 Affidavit of Not Black Listed on stamp paper with notary
8 Affidavit of Turnover on stamp paper with notary
9 Address Proof/ID. Proof of Individual/Partners/Directors
10 Copy of A Class approved valid license
12 Copy of GST Registration
13 Power of Attormey in case of the firm
14 Copy of partnership deep in case of the firm
15 Blood relation affidavit on Rs. 100.00 stamp paper.
16 Lo?kkS"k.kk 'kiFk i= :0 100-00 ek= ds LVkEi isij ij
17 Affidavit of Turnover on stamp paper with notary
Select, At Par, Excess (+), Less (-) IOCL Select Excess (+) Less (-) Excess (+) Less (-)
Tender Inviting Authority: GM(E&M)
Name of Work: M/o Authority Building (Annual Operation and maint. of 33/11 kv sub station in Sector -96, Noida)
Contract No: 17/GM(E&M)/S.M,E/M-3/2025-26
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
1 Operation of 33/11 KV Sub-Station round the clock in 3 shifts of 8 hours each by a team comprising of one electrician, skilled operator (having minimum qualification of ITI (Electrician grade) and one unskilled helper in each shift for operation of S/S equipments including maintenance of 11 KV incoming and outgoing Switchgear panels, 33 KV Switchgear pannels, battery and battery charger, 33/11 KV Transformer with control pannels, HT/LT Cable/Lines along with all associated equipments installed at 33/11 KV Sub-Station compus, (Contractor may deploy required man power, as and when required for attending breakdown within minimum time as detailed in Tech. Specification and distribution code) and maintain the required records as per U.P.P.C.L. (AOR) 1 Job Excess(+) Full Conversion INR
2 S/Filling of 20 mm. stone grit in yard of size26x36mtr 75 mm. thick complete in all respects. (AOR) 200 Cum Excess(+) Full Conversion INR
3 New Transformer oil for Transformer of approved make as per direction of E/I. 1000 Ltr. Excess(+) Full Conversion INR
4 Dehydration charges of Transformer oil as per direction of E/I. 6000 Ltr. Excess(+) Full Conversion INR
5 Testing and servicing of 11KV VCB such as Programming of IDMT relay, Servicing of Breaker, Primary injection test on 11KV indoor type C.T.etc complete in all respect. 46 Nos Excess(+) Full Conversion INR
6 S/E of 33 KV Lightning Arrestors with Structure made of M.S. Channel 125x65 mm. 13.1Kg/M top of M.S. Angle 50x50x6 mm. 4.5 Kg/M Lightning Arrestors/Post Insulator are to be mounted on M.S. Plate of 200x150x8 mm. Height of structure is to be 3.5 Mtr. above ground and 1 Mtr. below ground on a 75 mm. thick cement concrete pad with 1:4:8 cement concrete foundation, making plinth of required height including all fabrication as per drawing complete in all respects Make: Elpro/Oblum/ W/S as per direction of E/I. (AOR) 2 Set Excess(+) Full Conversion INR
7 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover (as per DSR 10.6.2) Sqm. Excess(+) Full Conversion INR
8 Supply, Installation, Commissioning & Testing of Battery charger 24V 24V/40Amp float cum Boost battery charger with dropping diodes suitable for I/P 230V±10%, 1 Phase, 50Hz Type FCBC as per PVVNL Specification, maximum continuous output ratings (outpur voltage in float mode 25.80 Volts and in Boost mode upto 33.0 Volts), output current 40A, Plus trickle charging current of battery floatmode 20A(Max),
8.1 Boostmode 20A Load terminal, 20A, Battery terminal 20A, Starting rate 10A upto 2.35 V per cell, Finishing rate 10 A upto 2.75 V Per cell, Output ripple 1% PP at full load and 25.8V DC, output regulation (floatmode) ±1% for ±10% supply voltage fluctuation and ±10% to 100% load variation, Automatic/manual mode of operation, Automatic and manual terminal charging, control configuration 1-phase full wave controlled, thyristor bridge feed through 1-phase
8.3 transformer and controlled by constant current/protential controller with load liminting feature and integrated non compartmentalized DCDB with 01 No 60A MCCB incomer, 5 Nos 16AMCB, sheet thickness 2mm, protection as per detail specification enclosed. IS: 13947) IP-42/ maximum Permissible input volage ±10% of 230V AC, Electronic protection with auto reset against short circuit and overload , DC over voltage short circuit at charger output terminals, thyristor by fuseing with protection against over charging, efficiency of rectified >65% at rated load, Power factor 0.7 lag at D.C. Current 230V Input with ANC cooling type and Class F type insulation. For Battery : 240V/200AH Tubular type Battery Bank consisting 12 Cells of each 2V/200 AH dry & uncharged along with wooden stand & accessories (AOR) 1 Nos Excess(+) Full Conversion INR
9 S/E of overhead line with ACSR (Painther/Dog) Conductor on pole/service bracket including binding etc. complete in all respects PS No 627 300 Kgs Excess(+) Full Conversion INR
10 S/E of P.G. clamp for ACSR (Painther/Dog) Conductor complete in all respects . UPERC cost data book 2018/ p-39 24 Nos. Excess(+) Full Conversion INR
11 Painting of (Complete sub-station) Terminal Gantry, Lighting arrestor, Busbar Gantry, Line Isolator & Bus Isolator Structures, Post insulator, Fencing, Poles and other structure complete with two coats of Al. paint over red oxide. (AOR) 1 Job Excess(+) Full Conversion INR
12 Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. P.S. No. 1131 4 Nos. Excess(+) Full Conversion INR
13 S/F of jointing of 300 sq. mm out door type type 33 KV jointing kit heat Shrinkable type for 33 KV Cable including cost of all material, labour, T&P etc. for proper completion Make : Raychem/ Denson/ Capseal as per direction of E/I. (UPERC P-47) 8 Nos. Excess(+) Full Conversion INR
14 Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 33 KV grade as required :
14.1 185 Sq.mm UPERC Pg-29 4 Nos. Excess(+) Full Conversion INR
15 S/Making of Straight through joint suitable for 300 sqmm x 3 core 33KV armoured cable as per ISS & Complete in all respects Make: Raychem, Denson, Cabseal. As per direction of E/I. (UPERC P-47) 2 Nos Excess(+) Full Conversion INR
16 S/E of 125x65 mm. MS Channel (13.10 Kg/M) 1.5 M long fixing in control room for OCB/VCB pannel complete in all respects as per direction of E/I.(AOR) 6 Nos. Excess(+) Full Conversion INR
17 Supply/Fixing of MS ladder of size 5 mtr long and 0.4m width with MS angle 40x40x6mm incl painting etc . complete in all respect as per direction of E/I.(AOR) 2 Nos. Excess(+) Full Conversion INR
18 Supply and laying of Control Cable for metering as per direction of E/I. (Kalinga/Grandley/Havells make) (AOR) Excess(+) Full Conversion INR
18.1 (a) 2.5 Sq. mm. 4 Core Copper 0.0 Mtr Excess(+) Full Conversion INR
18.2 (b) 2.5 Sq. mm. 10 Core Copper 0.0 Mtr Excess(+) Full Conversion INR
19 Supply of submersible pump CRI make having cost grained cast iron casting fitted with dynamically balaced gun metal impeller stainless steet shaft water lubricated bearing proteacted from sand and other suspended particles and driven with 3 HP AC Single phase 220 volt. AOR Nos Excess(+) Full Conversion INR
S/F 5 HP Submersible pumpset of Three Phase 440 volt. complete with all respect.make Kirloskar / G.E ./ CRI (AOR) 1 Nos Excess(+) Full Conversion INR
21 S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504
21.1 i) 300 Sq.mm. 72 Nos. Excess(+) Full Conversion INR
22 Location and pin pointing of 11/33 KV HT cable fault exposling the same in the underground 11KV HT cable including digging of trench upto the depth of the cable. Cutting the faulty cable and sealing of the faulty cable by providing fault location machine with operator (Cable fault locator) Complete in all respects as per direction of Engineer in charge (AOR) Nos. Excess(+) Full Conversion INR
23 Repairing of 11KV fuse wire/Jumper i/c supply and fixing of required size conductor, fuse wire of 11KV Line/DP structure of Transformer by takinng shutdown from UPPCL Department with all safety instruments like-safety belt, Gloves, shoes and other necessary items complete including all taxes. Nos. Excess(+) Full Conversion INR
Hiring charges of Mobile Hydraulic Crane 35 tonne capacirty (173HP) including fule and other T & P for shifting of RCC slab on cable trench as per direction of E/I. Hr. Excess(+) Full Conversion INR
25 Supply and burring of Safe Earthing Electrode T-19 (Hot Dip Galvanized), Length up to 2000mm, outer pipe 50mm, inner pipe 25, terminal Dia 12 mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonry husing (from electrode terminal to switch board, cost of 25 x 3 G.I . strip will be extra) Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. PS No. 725 (A) 4 Nos. Excess(+) Full Conversion INR
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joint with line sand etc. all completed as per directed by E/I. (DSR Civil-18/I.No.-16.68/P-283) 0.0 Sqm Excess(+) Full Conversion INR
27 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar 0.0 Cum. Excess(+) Full Conversion INR
28 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: -a)-Cement mortar 1:4 (1 cement : 4 coarse sand). 0.0 cum Excess(+) Full Conversion INR
29 12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand). 0.0 Sqm Excess(+) Full Conversion INR
30 Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requried DSR 2018/14.7 P-48 0.0 Cum Excess(+) Full Conversion INR
31 Providing and laying in position cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) :6 graded stone aggregate 40 mm nominal size) in Foundation of Pump,DG Set etc. Including from work etc. as requried DSR 2018/14.9 P-48 0.0 Cum Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
technical_2092710.pdf
techsummary_2092710.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Cap.xls
Additional Documents • 0.04 MB
TD.pdf
Tender Documents • 1.32 MB
BOQ_2092710.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid