Construction of Central Bank of India Office building at Amaravati, Andhra Pradesh
NBCC/RBG/South/CBOI/Amaravati/2026/31
NBCC/RBG/South/CBOI/Amaravati/2026/31
Open Tender-Domestic
Civil Works - Buildings
Andhra Pradesh
₹59,000
₹46.1 L
31 Jul 2026
31 Jul 2026
21 Aug 2026
21 Aug 2026
DSR Total with NON DSR TOTAL AMOUNT
DSR Total with NON DSR TOTAL AMOUNT
ABSTRACT OF COST-CIVIL
S NO ITEM OF CIVIL WORK
All Figures are in Rs. All Figures are in Rs.
1.00 Earth Work Rs. 11148880 0
2.00 Concrete Work Rs. 1154896 0
4.00 Brick Work Rs. 11949928 0
5.00 Marble Work Rs. 303850 0
7.00 Steel Work Rs. 1462983 0
8.00 Flooring Work Rs. 15789507 10579402
9.00 Roofing Work Rs. 852611 4704039
10.00 Finishing Work Rs. 12294876 0
11.00 Aluminium Work Rs. 351258 2951956
12.00 Structure Glazing Rs. 13033835 0
13.00 Water Proofing Rs. 8082804 0
15.00 Road Work Rs. 1927233 0
16.00 Rainwater Harvesting Work Rs. 595651 0
17.00 Miscellaneous Work Rs. 0 5755244
Total Amount Rs. 315798944
Total Amount Rs. 315798944
Contractor 3 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
1.00 2.0 EARTH WORK
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm
deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas
(exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal
of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers
1.03 2.25 not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 3705.00 Cum 196.00 726180.00
50 m and lift upto 1.5 m.
Disposal of surplus earth by mechanical transport including loading, unloading for a lead upto 10.00
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and
dressing complete.
2.34 Supplying chemical emulsion in sealed containers including delivery as specified.
2.34.1 Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 655.00 Litre 234.75 153761.25
Diluting and injecting chemical emulsion for POSTCONSTRUCTIONAL anti-termite treatment
(excluding the cost of chemical emulsion) :
Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart
2.35.3 including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse
sand) to match the existing floor :
2.35.3.1 With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 1178.00 Sqm 310.05 365238.90
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked
Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto
1.09 2.25(a) a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in 275.00 Cum 700.50 192637.50
foundation trenches, plinth, sides of foundation etc. complete for all lift.
Total Earth Work : 11148879.86 0.00
2.00 4.0 CONCRETE WORK
Providing and laying in position cement concrete of specified grade excluding the cost of centering and
shuttering - All work up to plinth level:
1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40
mm nominal size derived from natural sources)
Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including
attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses,
2.02 4.2 parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five
level, excluding the cost of centering, shuttering and finishing :
i) 4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 1.00 Cum 9895.20 9895.20
1:3:6 (1 cement : 3 coarse sand (zone-Ill) derived from natural sources: 6 graded stone aggregate 20
mm nominal size derived from natural sources)
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse
sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Extra for providing and mixing water proofing material in cement concrete work in doses by weight of Per 50 kg
cement as per manufacturer's specification. cement
Contractor 4 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using
2.05 4.13 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a 41.00 Sqm 146.15 5992.15
piece of cloth lightly soaked in kerosene oil.
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-Ill)
derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural
2.06 4.17 sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated 121.00 Sqm 749.30 90665.30
and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top
Extra for concrete work in superstructure above floor V level for each four floors or part thereof by
mechnical means.
Total Cement Concrete work : 1154896.15 0.00
3.00 5.0 R.C.C. WORK
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced
cement concrete work; using coarse aggregate and fine aggregate derived from natural sources,
Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended
proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and
workability without impairing strength; including pumping of concrete to site of laying, curing, carriage
for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction
3.01 5.33 of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the
minimum specified cement content in design mix shall be payable separately. In case the cement
content in design mix is more than 110% of the specified minimum cement content, the contractor shall
have discretion to either re-design the mix or bear the cost of extra cement.
5.33.1 All works upto Plinth level
5.33.1.2 Concrete of M30 grade with minimum cement content of 350 kg /cum 2592.00 Cum 9655.70 25027574.40
3.02 5.33.2 All works above plinth level upto floor V level
5.33.2.2 Concrete of M30 grade with minimum cement content of 350 kg /cum 1265.00 Cum 10011.35 12664357.75
3.03 5.38 Extra for R.C.C./ B.M.C/ R.M.C. work above floor V level for each four floors or part thereof. 414.00 Cum 355.65 147239.10
Analysed on Reinforcement for RCC work including straightening, cutting, bending, placing in position and binding
DSR all complete at all level and height
CRS TMT bars of grade Fe-550D. 669388.00 Kg 129.00 86351052.00
4.04 5.9 Centering and shuttering including strutting, propping etc. and removal of form for :
a) 5.9.1 Foundation, footing, bases of columns etc. for mass concrete 710.00 Sqm 392.15 278426.50
b) 5.9.3 Suspended floors, roofs, landings, balconies and access platform 4874.00 Sqm 927.25 4519416.50
c) 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers 4755.00 Sqm 736.40 3501582.00
d) 5.9.19 Weather shade, Chajjas, corbels etc., including edges 262.00 Sqm 951.10 249188.20
e) 5.9.7 Stairs, (excluding landings) except spiral-staircases 80.00 Sqm 764.95 61196.00
f) 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts 1382.00 Sqm 961.30 1328516.60
g) 5.9.4 Shelves (Cast in situ) 51.00 Sqm 927.25 47289.75
Small lintels not exceeding 1.5 m clear span, moulding as in cornices, window sills, string courses,
bands, copings, bed plates, anchor blocks and the like
i) 5.9.16 Edges of slabs and breaks in floors and walls
j) 5.9.14 Extra for shuttering in circular work (20% of respective centering and shuttering items) 28.00 Sqm 192.26 5383.28
k) 5.9.2 Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 5827.00 Sqm 842.50 4909247.50
4.05 5.30 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 203.00 metre 78.40 15915.20
Contractor 5 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping
4.06 5.11 etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every
additional height of 1 metre or part thereof (Plan area to be measured).
5.11.1 Suspended floors, roofs, landings, beams and balconies (Plan area to be measured) 6205.00 Sqm 384.30 2384581.50
4.07 MR Core cutting for fire & plumbing
4.00 6.0 BRICK WORK
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation
6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) 509.00 Cum 7132.25 3630315.25
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level in all shapes and sizes in :
6.4.2 Cement mortar 1:6 (1 cement: 6 coarse sand) 128.00 Cum 9105.95 1165561.60
Extra for brick work / AAC block masonry / Tile brick masonry in superstructure above floor V level, for
each four floors or part thereof by mechanical means.
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
foundations and plinth in :
6.12.2 Cement mortar 1:4 (1 cement :4 coarse sand) 1.00 Sqm 905.05 905.05
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in
superstructure above plinth level up to floor V level.
6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) 442.00 Sqm 1123.80 496719.60
Extra for half brick masonry in superstructure, above floor V level for every four floors or part thereof by
mechanical means.
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry 100 mm/ 125 mm thick with
Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super structure
4.08 6.38 above plinth level up to floor V level in cement mortar 1:4 (1 cement: 4 coarse sand ). The rate includes 82.00 Cum 10195.45 836026.90
providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Providing and laying Autoclaved Aerated concrete(AAC) blocks masonry with 150 mm to 300 mm thick
with Grade-1 AAC blocks of density 551 to 650 kg/cum conforming to IS:2185 (Part 3) in super
structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved
block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge.
(The payment of RCC band and reinforcement shall be made for seperately).
Total Brick Work : 11949928.40 0.00
5.00 8.0 Marble WORK
Contractor 6 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine
cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size,
approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including
rubbing, curing, edge moulding, facia and polishing to edges to give high gloss finish etc. complete at
8.2.2 Granite Stone Slab of Colour Black, Cherry/Ruby red
i) 8.2.2.1 Area of slab upto 0.50 sqm 2.00 Sqm 5413.50 10827.00
ii) 8.2.2.2 Area of slab over 0.50 sqm 42.00 Sqm 5136.30 215724.60
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform,
vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar
taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep
and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and
5.03 8.10 embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse
sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and
finished smooth.
8.10.2 Granite Stone of approved shade 7.00 Sqm 4051.85 28362.95
Total Marble Work : 303849.55 0.00
6.00 9.0 Wood WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought
6.01 9.1 framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast
lugs or dash fastener shall be paid for separately).
9.1.1 Second class teak wood 6.00 cum 142949.70 857698.20
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type,
core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply
veneering with vertical grains or cross bands and face veneers on both faces of shutters:
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 591.00 Sqm 2392.65 1414056.15
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt /
suede finish with high density protective surface layer and reverse side of adhesive bonding quality
conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of
flush door shutters (over all area of door shutter to be measured).
Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than
6.05 9.96 grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws
etc. complete :
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade
6.06 9.97 AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.
Providing and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of
6.07 9.113 approved quality for aluminium door, with necessary screws etc complete as per direction of Engineer- 102.00 Sqm 850.05 86705.10
Contractor 7 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing aluminium tower bolts, ISi marked, anodised (anodic coating not less than grade
6.08 9.97 AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc.
Providing and fixing stainless steel fancy handle of approved make fixed with SS screws etc. complete
as per direction of Engineer-in-charge.
Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not
6.10 9.101 less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with
necessary screws etc. complete.
9.101.2 Twin rubber stopper 112.00 each 72.35 8103.20
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand
6.11 9.83 logo with ISi, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), 112.00 each 1124.85 125983.20
with necessary accessories and screws etc. complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts,
6.12 9.53 nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 814.00 each 228.85 186283.90
coarse sand: 6 graded stone aggregate 20mm nominal size).
Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded)
6.13 (overall area of door shutter to be measured):
9.24.1 Rectangular or square 143.00 Sqm 199.15 28478.45
Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on
vertical sides having built in rebate made out of 1.6 mm thick GI sheet (Zinc coating not less than 120
gm/sqm) suitable for mounting 120 minutes Fire Rated Glazed Door Shutters. The frame shall be filled
with mineral wool Insulation having density minimum 96Kg/sqm. The frame will have a provision of G.I.
anchor fastners 14 nos (5 each on vertical style & 4 on horizontal style of size M10 x 80) suitable for
fixing in the opening along with factory made template for SS ball bearing hinges of size 100x89x3 mm
for fixing of fire rated glazed shutter. The frame shall be finished with an approved fire resistant primer
or powder coating of not less than 30 micron in desired shade as per the directions of Engineer - in-
Charge. (Cost of SS ball bearing hinges is excluded).
Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 minutes Fire rating
conforming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by
Engineer-in-Charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side
rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6 mm thick G.I. sheet
6.15 9.162 (zinc coating not less than 120 gm/ sqm) duly filled mineral wool insulation having density minimum 96 91.00 Sqm 12017.90 1093628.90
kg/ cum and fixing with necessary stainless steel ball bearing hinges of size 100x89x3 mm of approved
make, including applying a coat of approved fire resistant primer or powder coating not less than 30
micron etc all complete as per direction of Engineer-in-Charge (panelling to be paid for seperately).
Contractor 8 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I.
beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/sqm) of size 20 x 33
mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c ,
including applying a coat of approved fire resistant primer/ powder coating of not less than 30 micron on
G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC 2016, IS
16231 (Part 3):2016 and as per direction of Engineer-in-Charge with glass of required thickness having
6.16 9.164 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 20 minutes of 91.00 Sqm 43677.65 3974666.15
insulation (El20). The manufacturer have to give test report/certification of fire glass and the glass
should have the stamp showing the value of E, EW & El. The glass shall be tested in approved NABL
accredited lab or by any other accreditation body which operates in accordance with ISO/IEC 17011
and accredited labs asort. The OEM shall have ISO 9001, BIFMA Level 2, Green Guard UL Gold
Certification, AIOTA, IGBC Gold rated factory certification and India Design Mark.e b
Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Latch & Lock on back
6.17 9.139 side of the Panic Latch of reputed brand and manufacture to be approved by the Engineer- in- charge, 46.00 each 8366.15 384842.90
PELMET: Fabricate and install pelmet made of 19 mm thick board, up to 300 mm high and in line with
6.18 MR external glazing as per details of Architect. Rate to include finishing exposed surfaces of the Pelmet 312.00 Metre 692.00 215904.00
with 1mm laminate.
5.5mm THICK FSP HDHMR BOARD: Providing and fixing in wall lining, partitions etc. Confirming to
ASTM E-84-2021 class1 one side 1mm decorative Lamination, having even grade low emission, high
6.19 MR moisture resistance, fire resistance, borer, termite & fungus resistance, green material and
environmental friendly with necessary fixing arrangement and screws etc. , complete as per direction of
Engineer-in-Charge
5.5mm thick FSP HDHMR Board 10.00 Sqm 623.00 6230.00
WOODEN BATTENS: Providing and fixing specified wood frame work consisting of battens 50x25mm
8.27 fixed with rawl plug and drilling necessary holes for rawl plug etc. including priming coat complete.
8.27.1 Kiln seasoned and chemically treated hollock wood 6.00 Cum 187277.65 1123665.90
GLASS FILMS: Providing & Fixing Frosted Translucent, cast PVC, self-adhesive vinyl, special
CRYSTAL-effect film to reproduce Sand-blasting effect on glass with customised designs, thickness of
2 mil (0.05mm) without adhesive & 3mil (0.8)with adhesive having minimum tensile strength of 3.5
pound/inch at 73 F(0.6 kg/cm at 23 C). Adhesion after 24hrs of installation should be 4 pounds/inch
(0.7 kg/cm) on Acrylic, Glass Polycarbonate: MCS warranty of 3yrs (if exposed to direct sunlight) to
15yrs (indoors) .
LACQUERED GLASS: Providing and fixing of 6mm thick annealed SGG Planilaque Evolution
(premium GRIHA rated lacquered glass from Saint-Gobain) of approved color by Architect/ Client /
Customer, fixed with SGG ULTRAFIX (compatible neutral core silicon/ double sided tape) on a
perfectly leveled 12mm thick water proof marine plywood / MDF / Mineral fibre board which is mounted
on the RCC wall/any other structure. Lacquered glass must be made industrially (via curtain coating
6.22 MR process); opaque (if viewed against a support wall), coated with PU lacquer (50 micron thick); color 64.00 Sqm 4917.00 314688.00
consistency (measured by Minolta spectrophotometer CM5081); highly durable (passes PERSOZ
hardness test for minimum 220 oscillatios); humid resistant (conforms to BS EN 1036 1999);
environmentally friendly (no lead, no arsenic, no copper, noformaldehyde); appropriate recycled content
(12% post industrial/ 6% post consumer); compressive strength (1000 MPa) & tensile strength (40
MPa), same as float glass;
Contractor 9 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
GYPSUM BOARD PARTITION: Providing and fixing partition upto ceiling height consisting of G.I. frame
and required board, including providing and fixing of frame work made of special section power
pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor
and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor
and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm
length or suitable anchor fastener or metal screws with nylon plugs and the studs 48mm wide having
one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor
and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts,
including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or
6.23 9.105 metal screws with nylon plugs at spacing of 450mm centre to centre, and fixing of boards to both side
of frame work byort. The OEM shall have ISO 9001, BIFMA Level 2, Green Guard UL Gold
Certification, AIOTA, IGBC Gold rated factory certification and India Design Mark.e bushings to ensure
smooth, scratch-free stacking. The entire understructure will be powder-coated, with a finish thickness
of 40 to 60 microns, ensuring long-lasting durability and a high-quality appearance. The OEM shall
have ISO 9001, BIFMA Level 2, Green Guard UL Gold Certification, AIOTA, IGBC Gold rated factory
certification and India Design Mark.+/- 5mm to be considered for dimensions Length, Depth & height
and tolerance of 5% to be considered in thickness. The OEM shall have ISO 9001, BIFMA Level 2,
75mm overall thickness partition with 12.5mm thick double skin fire rated Glass Reinforced Gypsum
9.105.1 (GRG) plaster board conforming to IS: 2095: part 3 (Board with BIS certification marks) 30.00 Sqm 2131.10 63933.00
Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free
uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having
minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4
profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild
steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads,
interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket,
hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of
matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14,
plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion
(if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners,
including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap
between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer
rod of approved size and quality, all complete as per approved drawing conforming to CPWD
6.24 specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of
uPVC profiles to be as per design approved by Engineer-in-Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with/ without high performance
coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately.
Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the
manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with
structure height more than 20m for all wind speeds
Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the
manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 - Part 3 (ii) Sites with
structure height more than 20m for all wind speeds
Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium
channel for roller track, wool pile, nylon rollers with SS 304 body.
Contractor 10 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Using R2 series with frame (70 mm & above) x (40 mm & above) & both glazed and fly screen sash (25
i) 9.147.A4.1 mm & above) x (50 mm & above) with zinc alloy (zamak) powder coated touch locks with hook. (Height 1.00 Sqm 10,993.55 10,993.55
upto 1.2 metre).
Using R4 series with frame (115 mm & above) x (45 mm & above) & both glazed and fly screen sash
ii) 9.147.A4.3 (44 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed 3.00 Sqm 12,372.25 37,116.75
panel along with multi- point locking system. (Height above 1.8m)
iii) 9.147.C1 Fixed window/ ventilator without mullion / transom.
9.147.C1.1 sing R1 series with frame (33 mm & above) x (35 mm & above). (Height upto 0.90 metre) 1.00 Sqm 8,247.25 8,247.25
9.147.C1.3 Using R3 series with frame (55 mm & above) x (45 mm & above). (Height upto 2.5 metre) 5.00 Sqm 7,080.05 35,400.25
Two track two panels sliding door with Aluminium channel for roller track, wool pile, zinc alloy (zamak)
iv) 9.147.B1 powder coated handle on every panel along with multi-point locking system, adjustable nylon rollers
with SS 304 body.
Using R3 series with frame (55 mm & above) x (40 mm & above) & sash (30 mm & above) x (74 mm &
above). (Height upto 2.5 metre).
Providing and fixing thermal insulation with Resin Bonded Fibre glass wool conforming to IS: 8183
having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall with screw,
rawel plug & washers and held in position by criss crossing GI wire etc. complete as per directions of
Engineer-in-Charge.
Total Wood Work : 13863870.80 597742.00
7.00 10.0 STEEL WORK
Steel work welded in built up sections/ framed work, including cutting, hoisting, hinges, ms handle as
7.01 10.25 required, fixing in position and applying a priming coat of approved steel primer using structural steel
etc. as required.
In gratings, frames, guard bar, ladder, railings, brackets, gates, safety grilled door and similar works
Providing and fixing carbon steel galvanised ( minimum coating 5 micron) dash fastener of 10 mm dia
double threaded 6.8 grade (yield strength 480 N/mm2), counter sunk head, comprising of 10 mm dia
polyamide PA 6 grade sleeve, including drilling of hole in frame , concrete/ masonry, etc. as per
direction of Engineer-in-charge.
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.,
including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary
7.03 10.28 accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of 12.00 Kgs 772.40 9268.80
the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for
payment purpose only weight of stainless steel members shall be considered excluding fixing
accessories such as nuts, bolts, fasteners etc.).
Total Steel Work : 1462983.25 0.00
8.00 11.0 FLOORING
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be
specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green,
black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12
mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @
3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Contractor 11 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the
manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory,
8.02 11.37 Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing 119.00 Sqm 1096.55 130489.45
with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching
pigment etc., complete
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)
with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours
8.03 11.41 and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey
cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments
etc., complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the
manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand &
manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse
sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and
matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles
will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber
mallet for placing the tiles gently and easily.
11.41A.3 Glazed Vitrified tiles Matt/Antiskid finish of size
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with
water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours &
8.05 11.46 shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),
jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement &
matching pigments etc. complete.
FLAMED FINISH GRANITE FLOORING : Providing and laying flamed finish Granite stone flooring in
required design and patterns, in linear as well as curvilinear portions of the building all complete as per
the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement
8.06 11.55 mortar 1:4 (1 cement: 4 coarse sand) laid and jointed with cement slurry and pointing with white cement
slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete
as specified and as directed by the Engineer-in-Charge :
11.55.1 Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 263.00 Sqm 3186.70 838102.10
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as
curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone
slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed
with cement slurry and pointing with white cement slurry admixed with pigment of matching shade
including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-
11.56.2 Polished Granite stone slab of all colour and texture except Black, Cherry/Ruby Red 176.00 Sqm 4481.30 788708.80
Granite stone slabs 18 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average)
Analysis of thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with
DSR pigment to match the shade of the slabs, including rubbing and polishing complete.
8.09 11.24 Extra for pre finished nosing to treads of steps of marble stone. 370.00 Metre 719.90 266363.00
8.10 11.25 Extra for marble stone flooring in treads of steps and risers using single length up to 2.00 metre. 126.00 Sqm 851.80 107326.80
Contractor 12 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar
refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped
surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse
sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including
rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm
height along the parapet walls in the same manner.
Providing and installation (by spray method) of projected cork spray for interior, exterior wall and roofing
surfaces. Wall surface must be dry, smooth and provided by civil contractor or client so the final finish
can be desired and standard. Product with 2-3mm spray to achieve best of the product advantages as
high performance against thermal conductivity, acoustic and thermal insulator, waterproofing,
ecological, anti-oxidant, anti-bacterial, rot proof, anti-humidity, green building, sustainable, organic &
natural material. Product must be sprayed over dry, levelled and smooth wall/ roof surfaces in dust free
and non-rainy/non humid climate condition for better performance.
Interior & Exterior projected cork spray must comply with below mentioned quality and technical
standards. Adhesion resistance by pull-off test - EN-ISO 1524: 2000 - ≥ 1,9 N/mm2.Thermal
conductivity - UNE-EN 12667 - 0,075 W/m. ºC.Tensile strength and elongation at break - EN-ISO 527-4
- 0,36 Mpa.Crack bridging capability - EN 1062-3:2008 - A1 (-20ºC).Thermal compatibility (freeze-thaw
cycles) - EN 13687-5 - ≥ 0,8 N/mm2.”No bubbles and cracks”.Water vapor permeability - EN ISO 7783-
1(-2) - Sd< 5m Class.Hazardous substances - EN 16516:2018 - Complies with 5.3.Volatile organic
compounds (VOC)- UNE EN ISO 17895 - Maximum product content 15.Sound absorption - EN ISO
354:2004 - aw = 0,10. installation/spray on façade and roofing saves 20%-25% of AC consumption and
made of 100% natural organic materials as base material 96% of cork granules, it helps government
agencies, engineers, architects, project owners to achieve green building and sustainable compliances.
Product must be with 10 years of warranty with acceptable aging decolouration with times. Spray
method and wall preparations as per company standards shall not be sprayed over non recommended
wall conditions and colour or patterns as per project architect or engineer approval.
EXTERIOR GRADE COMPACT HIGH-PRESSURE LAMINATE (HPL) CLADDING: Providing and fixing
6mm thick Suede Finish Greenlam, or equivalent exterior grade Clad (High Pressure Laminates) made
up of 1300mm x 3050mm in size and conforming to EN 438-6:2016 standard, EDF Grade. Exterior
CLAD HPL should be made under high pressure, using thermosetting Phenolic resin treated kraft
layers, Amino plastic resin treated Exclusive & UV conforming Exterior Grade Decorative paper on both
sides and UV protection layer above the décor papers on both sides. Clad should be resistant to wet
conditions and meets permissible increase on mass, have density >1.35 gm /cm3, UV resistance of a
minimum of 4 on a grey scale rating after 1500 hours, Resistance to artificial weathering including light
fastness of a minimum rating of 4 (after 650 MJ/m2 radiant exposure). The product must conform to
European Fire-Retardant norms of Bs1d0 when classified in accordance with EN 13501-1.
Contractor 13 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
8.13 MR The Fire-Retardant Additive must be Halogen free to protect the environment. HPL must be a green
product conforming to GRIHA, GreenPro and Green Guard Gold certification and meet Anti bacterial
and Anti-termite property under JIS Z2801. Finish and color of compact laminates should be finalized
under direction of Engineer –in-charge. Clad should be installed on Aluminum tubular substructure in
the size of 50mm x 25/50mm or as per site requirement fixed at a maximum center-to-center distance
of 400mm to 600mm with the help of 5mm dia color matching rivets with sliding holes and fixed holes
on the HPL. The aluminum tubular substructure should be fixed on wall with the help of dead load
bearing brackets and wind load bracket by 10mm fastener. Wind load bracket will have vertical slot &
dead load bracket will have in horizontal slot & maintain 6mm both horizontal and vertical gap between
two installed clad panels. Shade/design of clad should be finalized under direction of Engineer –in-
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a
11.3 floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate 296.00 Sqm 614.20 181803.20
RAISED FALSE FLOOR: Providing and fixing removable raised/false access flooring with systemand
its components of approved make for different plenum height with possible height adjustment upto
50mm, comprising of modular loadbearing floor panels supported on G.I. rectangular stinger frame
workand G.I. Pedestal etc. all complete, as per the architectural drawings, as specified and as directed
by Engineer-in-charge consisting of:
(a) Providing at required spacing to form modular framework, pedestals made out of GI tube of
thickness minimum 2 mm and 25 mm outer diameter, fully welded on to the G.I. Base plate of size
100mm x 100mm x 3mm at the bottom of the pedestal tube, G.I. pedestal head of size
75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer diameter with two GI Check nuts
screwed on the stud for level adjustment upto 50mm, locking and stabilizing the pedestal head in
position at the required level. The pedestals shall be fixed to the subfloor (base) through base plate
using epoxy based adhesive of approved make or the machine screw with rawl plug.
(b) Stringers system in all steel construction hot dipped galvanized ofrectangular size
570x20x30x0.80mm thick having holes at both ends for securing the stringers on to the pedestal head
using fully threaded screws ensuring maximum lateral stability in all directions, the grid formed by the
pedestal and stringer assembly shall receive the floor panel, this system shall provide adequate solid,
rigid support for access floor panel, the system shall provide a minimum clear uninterrupted clearance
8.15 between the bottom of the floor for electrical conduits and wiring etc. all complete as per the
architectural drawings, as specified and as directed by the Engineer-in-charge.
Contractor 14 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
(c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled Steel anti static
high pressure Lamination of 800H grade (FS800H). Access Floor panel shall be steel welded
construction with an enclosed bottom pan with uniform pattern of 64 hemispherical cones. The top and
bottom plates of Steel Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum
64 welds in each dome and 20 welds along each flange). The panel should be Corroresist epoxy
coated for lifetime rust protection and cavity formed by the top and bottom plate is filled with Pyrogrip
noncombustible Portland cementitious core mixed with lightweight foaming compound. The access
floor shall be factory finished with Anti-static High Pressure laminate with Non Warp technology upto
1mm thickness for superior adhesion and Surface flatness within 0.75mm.The panel is to withstand a
Concentrated Load of 363 kgs applied on area 25mm x 25mm without collapse in the centre of the
panel which is placed on four steel blocks. The panel will withstand and Uniformly Distributed Load
(UDL) minimum 1250 kg/sqm and an impact load of 50kg all complete as per the approved
manufacturers specification and as per the direction of Engineer-in-charge. All specification must be
printed on the side of the panel to ensure the quality of the product.
11.54.2 450mm Finished Floor Height (FFH). 24.00 Sqm 5977.35 143456.40
ALUMINIUM SKIRTING: Supply of 100mm Aluminium (Grade 6063) Skirting with 15 micron anodising
8.16 MR In Natural Finish. Thickness 1.30 to 1.50mm. Designed to conceal screws. Seamless finish. Complete 127.00 Metre 346.00 43942.00
with Rubber/ PVC Jointers and Gasket.
CARPET TILES: Supply and fixing of Modular Carpet Tiles/ Planks made of Yarn type Nylon 6; Tufted
Textured Loop Pile manufacturedusing 100% Recycled Content Nylon, 100% Solution Dyed, Soil/Stain
Protection- Protekt²® , Preservative Protection - Intersept® , tiles of size 100 cms x 100 cms/ 50cm
50cm, with Glasbac having tufted yarn weight of 14-18Oz and average yarn density of 4500-6000
oz/cu. yd., Nominal total thickness 6 mm minimum, Minimum Recycle Content of 60% , Stability -
Delaminating ASTM D3936 ≥ 3.0 lbs/in, Wear - Castor Chair EN 985 > 2.4 Rating @25,000 cycle, ISO
10361 (ASTM D5417) ≥ 3.5 Rating @20,000 cycles (Heavy Use), Colour Fastness to Light AATCC 16
Part 3 ≥ 4 @ 60 Hours, Colour Fastness to Rubbing and Crocking AATCC 165 ≥ 4, Colour Fastness to
Water AATCC 107 ≥ 4, Flammability Methenamine Pill ASTM 2859 - 7 of 8 passing, Flammability -
Radiant Panel ASTM E648 > .45 watts/sq. cm., Flammability - Smoke density ASTM E662 < 450,
Antistatic AATCC 134 < 3.0 kV, Antimicrobial Treatment ASTM E-2471, Complete Inhibition AATCC
174 Parts II & III 99% reduction. No mold 7 Days. Acoustic - Nylon Absorption Coe cient - NRC 0.0 -
0.2, Dynamic Loading ISO 2094 < 15% Thickness loss, Green Carpet ASTM D5116, CRI Green Label
Plus certified for indoor air quality, NSF/ANSI 140 Gold including fixing/ installation with Low/ Zero VOC
content Adhesive.
IPS FLOORING: 52mm thick cement concrete flooring with concrete hardener topping, under layer 40
mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal
size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2
8.18 11.40 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 296.00 Sqm 978.45 289621.20
kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding
the cost of nosing of steps etc. complete.
12 mm THICK HDHMR BOARD RAW : 12 mm thick FSP HDHMR Board: Providing and fixing in wall
lining, partitions etc. Confirming to ASTM E-84-2021 class1, having even grade low emission, high
moisture resistance, fire resistance, borer, termite & fungus resistance, green material and
environmental friendly with necessary fixing arrangement and screws etc. , complete as per direction of
Engineer-in-Charge
12mm thick FSP HDHMR Board 1334.00 Sqm 730.00 973820.00
Contractor 15 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing stainless steel clamps of required size and shape for anchoring stone wall lining to
the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse
sand), including making the necessary chases in stone and holes in walls wherever required.
VIC STRIP WALL PANELLING : Supply & Installation of Vicstrip (single slat/double slat)having size of
2400x600x12mm(+/- 2mm) thickness, backing of PET panel with front facia of 1mm laminate. The
product use for absorption of medium and high frequency range with NRC of 0.50 direct fix. Panel
Should be anti fungal as per ASTM G:21 and also Non-toxic, non-irritant, and fire complying with safety
standards confirm to Class 1 Fire Ratings tested as per BS 476 Part 6 passes (Fire Propagation) & Part
7 class2 (Surface spread of flame) ,for interior applications-The product should be 100% make in india
and OEM must have ISO CERTIFICATIONS- complying to- IGBC membership ISO 14184-2 (Release
formaldhyde) ISO 9001 (Quality Mangement System) ISO 14001 (Environmental Management System)
ISO 45001 (Ocupational helth & safety management system)
EMBOSSED PET PANEL : Supply & Installation of VMT Embossed 12mm PET panels which shall be
processed with VMT technology for surface customised colour options with available pattern as per the
designers requirement, the panel shall be made from-100% polyester fiber, with up to 70% recycled
fiber. size of panel 2800mm x 1200mm (± 0.5mm). Panel Should be anti fungal as per ASTM G:21
and also Non-toxic, non-irritant, and fire-resistant complying with safety standards confirm to Class 1
Fire Ratings tested as per BS 476 Part 6 (Fire Propagation) & Part 7 (Surface spread of flame) ASTM
8.22 MR. E 84 CLASS A, EN 13501 PART 1C,s2,d0 for interior applications. Noice reduction coefficient (NRC) - 50.00 Sqm 3000.00 150000.00
0.70 with 9 mm backing direct fix, 0.75 with 12 mm backing direct fix and 0.90 with 25 mm backing
direct fix. The product should be 100% make in india and OEM must have ISO CERTIFICATIONS-
complying to- IGBC Membership ISO 14184-2 (Release formaldhyde) ISO 9001 (Quality Mangement
System)ISO 14001 (Environmental Management System)ISO 45001 (Ocupational helth & safety
management system)
Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The
ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering
process and finally finished by floating, brooming with wire brush etc. complete as per specifications
8.23 16.75 and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). 344.00 Cum 9823.80 3379387.20
(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per
design mix is payable/ recoverable separately).
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after per cm
making the joints dust free with high pressure air jet cleaners, all complete as per direction of the depth per
8.24 16.45 Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound 230.00 cm width 5.30 1219.00
impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board per metre
and IS: 1834 for hot sealing bitumen compound grade A.) length
Total Flooring Work : 15789507.40 10579402.00
9.00 12.0 ROOFING
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 stone aggregate 10
12.21 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per
standard design :
Contractor 16 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement :
2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400
9.02 12.22 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, 26.00 Each 298.25 7754.50
rounding the edges and making and finishing the outlet complete.
GYPSUM BOARD CEILING: Providing and fixing false ceiling at all height including providing and fixing
of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc
coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25
mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange
fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of
cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size
and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm
with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed
in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia
x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high
12.45 having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of
9.03 rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of
gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25
mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3
layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per
manufacturer's specification and also including the cost of making openings for light fittings, grills,
diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings,
specification and direction of the Engineer in Charge but excluding the cost of painting with
12.5mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS
certification marks)
WOODEN VENEER/ BAMBOO CEILING: Providing and fixing wooden veneer / bamboo ceiling by
Fixing Natural OAK Veneer 4 mm / natural bamboo shoots, mesh, screens, gall screen complete as per
9.04 MR the design on 12mm UnderlayFire retardent Ply fixed to a subframe made using 50mm X 50mm Kiln 49.00 Sqm 8223.00 402927.00
seasoned and chemically treated hollock wood fixed to RCC ceiilng using Fastners
Contractor 17 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
POLISH: Polishing in high gloss/matt finish melamine clear polish on wood work in required
color/wooden shade texture with following process in the sequence as detailed below:
1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of
2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd
coat is allowed to dry for 8 to 12 hrs.
3. On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample water to remove
excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied
9.05 MR with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be 199.00 Sqm 2467.00 490933.00
allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to
dry for 12 hrs.4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear
polish and melamine thinner in required proportion.This 1st coat is allowed to dry for 24 hrs then this
dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final
melamine polish is applied with compressor pressure spray gun using melamine clear polish and
melamine thinner mixed in required proportion complete coat to be done in 1 or 2 layers without gap of
time.) as per direction of Engineer-in-Charge.
WAVE BAFFLE CEILING: To Supply & Install Custom made Vertical curve Polylam Blades Ceilings as
per the design intent. The vertically curve baffle system POLYLAM exhibiting space- delineating
characteristics. The system comprises vertically curve baffle with 75-150mm deep curved rafters
manufactured out of 1.2mm Aluminium to provide wave effect. The module for fixing baffle shall be
150mm centres as per design requirement. The carrier rails run perpendicular to the baffles axis and
can be mounted with M6 threaded rods using technical approved fasteners as per EN 13964
9.06 MR standards. The individual baffle lengths between 1200- 2400 mm can be selected. Baffles lengths less 102.00 Sqm 8998.00 917796.00
than 1500mm required two carrier rails mounted at the baffle ends. Baffle longer than 1500mm require
additional carrier rails mounted in the centre. Finish RAL Powder Coated.No Pre Coated products shall
be accepted. The spacing of the grid angles is according to the requirements of DIN 18168 and DIN EN
13964 and quality controlled to ISO 9001:2015 approved by SIS & LEED certification by Indian Green
Building council (IGBC).
Contractor 18 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
PERFORATED GYPSUM BOARD CEILING: Providing and fixing suspended false ceiling Size
1188x1998x12.5mm Globe perforation 8/18 with 8.7% perforation with NRC upto 0.6 : Regular round
perforation of glass fibre reinforced gypsum material, which includes providing and fixing GI perimeter
channels of size 0.55 mm. Thk. having one flange of 20 mm and another flange of 30 mm and web of
27 mm along the perimeter of the ceiling, screw fixed to brick wall/ partition with help of nylon sleeves
and screws, at 610 mm centers. The suspended GI intermediate channels of size 45 mm,0.9mm thk
with two flanges of 15 mm each from the soffit at 900 mm centers with ceiling angle of width 25mm x
10mm x 0.55mm thk fixed to soffit with GI cleat and steel expansion fasteners. Ceiling section of 0.55
mm thk having web of 51.5mm & two flanges of 26mm each with lips of 10.5mm are fixed to the
intermediate channels with help of connecting clips and in direction perpendicular to the intermediate
channel with centers of 333 mm perforated gypboard is then screw fixed to ceiling section with 25 mm
9.07 MR dry wall screws at 300 mm centers to G.I. framing in perfect level. Screw fixing is done mechanically 11.00 Sqm 3152.00 34672.00
either with screw driver or drilling machine with suitable attachment. Finally the boards are to be joined
and finished so as to have a flush look with uniflot.
Cleaneo Technology - Air purification & Air quality.Active reduction of air polluants thanks to Cleaneo
Technology effectively reduces concentrations of VOC’s like alcohol, aldehydes, ketons and esters as
well as unpleasant odours from e.g. food or cigarette smoke
Air purification properties tested according to CEN standards and VDI guidelines by Fraunhof Insistute
for Building Physics.
The false ceiling surfaces shall be prepared to the satisfaction of the Architect, and shall be applied
with two coats of primer to the satisfaction of Architects.
300X1200 SUSPENDED FALSE CEILING : Providing and fixing suspended false ceiling microlook
tegular edge tile with 15 mm thickness, easily demountable tile, manufactured from High density glass
wool, visible surface is a batch painted glass tissue in white, back of the tile covered with glass tissue.
Size 1200x600x15mm Acoustics-Sound absorption(Alpha W) - 0.95 at 200 mm o.d.s as per EN ISO
354 Acoustics-Sound absorption Class - Class A at 200 mm o.d.s as per EN ISO 11654Acoustics-
Articulation class - 180 as per ASTM E1111, ASTM E1110,NRC - 0.9 NRC as per ASTM C
423,Humidity Resistance -Permanent ambient RH up to 95% at 30*C without sagging, warping and
delaminating ( 13964:2014). Fire Safety - Tested and classified as non combustible according to EN
ISO 1182 with reaction to fire classification class A2 s1 d0 according to EN 13501-1 - European
METAL CEILING FOR WET AREAS : Providing and fixing G.I Plain 84mm wide x12mm deep panel
with 16 mm flush profile to make it 100mm module of length upto 6mtr, shall be roll formed out of
0.5mm thick Powder Coated .The top coat of panel shall be 60 micron polyester coated finish in
approved colour. The panel shall be factory cut in up to 6Mtr OR required length. Accessories
Detail:Carrier: 32 mm wide and 39mm deep, made out of 0.5mm thick steel backed with enameled
black paint having cut out to hold on panel in a module of 100mm closed. The joint of two carriers shall
be joined by means of carrier splices maintaining a module of 100mm .4mm dia galvanized rod with
special height adjustment butter fly clips made out of SS steel sheet. The edge profile G.I.shall be
matching with the panel.
ACOUSTIC BAFFLE CEILING: Supply and installation of 2400 x 200x 18 mm PET Panels with a
9.10 MR density of 1850 gsm, material -100% polyester fibre , 100% recyclable and highly durable with GI U 10.00 Sqm 4137.00 41370.00
channel and clutch wire for hanging.
Contractor 19 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
OPEN CELL CEILING: Supply and installtion of Metal open Cell ceiling made of GI made and powder
coated of approved RAL shade. open cell ceiling with cell size of 50 x 50 mm. The cell is formed by
locking of upper sections and lower sections with U shaped profiles of 40mm height 15mm width and
595 mm length. The upper and lower sections when locked are locked with end panels on all 4 sides to
form a tile of 595 x 595mm. Each tile is installed on a 15mm T Grids system The grids system is formed
by locking of GI made Main T of 3000mm or 3600mm length and GI Cross T of 600mm at 600mm c/c.
GI wall angle 25x25 x0.4x3000mm {Material-GI(IS513),YS-280Mpa,Finish-Galvanised 90GSM(IS277)}
9.11 MR is fixed along the periphery of the ceiling with wooden screws at 300mm centers or Hilti HPS 6x40mm 316.00 Sqm 2800.00 884800.00
placed at 600 mm c/c. The grid system is suspended by 4 mm wire rod with adjustable clip, connected
to the grids system at 1200mm c/c. The suspension rod with clip is fixed to the slab by means of soffit
cleat and rawl plug ( fastner), at 1200mm c/c. Gyproc® soffit cleat 27x37x25x1.6mm {GI(IS513)YS-
260Mpa, Finish-Galvanised 120GSM(IS277) } is fixed with Gyproc® Rawl Plug- Ø8x45mm {Material-IS
513 CR1 grade, Zinc coating (7 to 8 microns) pull out load- 6.8kN for M30 concrete grade} Suspension
etc. all complete as per direction of Engineer-in-charge.
Total Roofing Work : 852610.65 4704039.00
10.00 13.0 FINISHING
10.01 13.4 12 mm cement plaster of mix :
10.02 13.16 6 mm cement plaster of mix :
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse
10.03 13.11 sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 2634.00 Sqm 518.55 1365860.70
Extra for plastering exterior walls of height more than 10 m from ground level for every additional height
of 3 m or part thereof.
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the
surface even and smooth complete.
Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic
13.83 Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying
additional coats wherever required to achieve even shade and colour.
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an
Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved
brand and manufacture
13.45 Finishing walls with textured exterior paint of required shade :
10.08 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior
primer applied @ 2.20kg/10 sqm
10.09 13.114 Melamine polishing on wood work (one or more coat). 6.00 Sqm 1192.30 7153.80
10.10 13.18 Neat cement punning. 234.00 Sqm 79.95 18708.30
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and
10.11 13.80 manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 130.00 Sqm 156.05 20286.50
13.37 Washing with lime to give an even shade :
13.37.1 New work (three or more coats) 1.00 Sqm 39.05 39.05
Total Finishing Work : 12294876.25 0.00
11.00 21.0 ALUMINIUM WORK
Contractor 20 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up
standard tubular sections/ appropriate Z sections and other sections of approved make conforming to
IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.
11.01 21.1 Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever
required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless
steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
(Glazing, paneling and dash fasteners to be paid for separately) :
21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron) 32.00 Kg 530.90 16988.80
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making
11.02 21.1.2 provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket
required (Fittings shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron 49.00 Kg 634.45 31088.05
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with
11.03 21.3 EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of
engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) 6.00 Sqm 1505.25 9031.50
21.3.3 With float glass panes of 8 mm thickness (weight not less than 20 kg/sqm) 139.00 Sqm 1685.40 234270.60
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather
11.04 21.8 silicon sealant over backer rod of approved quality as per architectural drawings and direction of
Engineer-in-charge complete
21.8.1 Upto 5 mm depth and 5 mm width 8.00 metre 96.75 774.00
Providing and fixing aluminium casement windows fastener of required length for aluminium windows
with necessary screws etc. complete
21.15.1 Anodized (AC 15) aluminium 2.00 Each 89.40 178.80
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete
as per direction of Engineer-in-charge
21.16.1 Anodized (AC 15) aluminium 2.00 Each 107.90 215.80
Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and
manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring
11.07 21.18 type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete 7.00 Sqm 5325.90 37281.30
as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately).
Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with
SS screws etc .complete as per direction of Engineer-in-Charge.
21.12.1 Anodized (AC 15 ) aluminium tubular handle bar 6.00 Each 575.75 3454.50
Providing and fixing 12mm thick toughened glass in Aluminium frame work including sealing with
11.09 EPDM / Neoprene gasket all complete as per the architectural drawings and the directions of engineer- 5.00 Sqm 3595.00 17975.00
SINGLE GLAZED SLEEK PARTITION: Supply and installation of aluminum profile for single-glazed
straight partition with top, bottom and side profiles of size 21mm x 30mm natural anodised finish and
11.10 MR suitable gaskets for insertion with 10mm thick clear toughened glass. It consists of 2 way polycarbonate 31.00 Sqm 10965.00 339915.00
profiles, 90 Degree L Junction and T Junction profiles and suitable fasteners for fixing profiles including
installation charges.
Contractor 21 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
SINGLE GLAZED SINGLE LEAF DOOR: Supply and Installation of door frame size 55X36mm and
single leaf single glazed stile door frame size 40x82mm with seals natural/black anodized finish with
Hardware: Flush Hinges(4 Nos) & Lever Handle with Narrow sash Lock 35mm backset, oval
11.11 MR escutcheons, strike plate, EPC both side key-70mm and saint gobain exposed door closer with Hold 4.00 Nos 109646.00 438584.00
Open unit with insertion of 10mm thick clear toughened glass and necessary seals to be provided all
around the door frames and drop down seal.
FIBRE WALL COVERING: Supply & Installation of Glass fiber based homogenous Woven/ non-woven
.1mm thick, 100-200 GSM Density brethable Wall Coverings. Material to be fire certified with minimum
Euroclass BS1D0 certification under EN13501, no harmful chemical coated with Oekotex Standard 100
certification and non-toxic in nature for closed enviornments with A+ attested for emission in indoor air.
Installation to be done over smooth, dry and dust-free substrate as specified with OEM recommended
adhesive by the supplier's authorized installer team. Installation measurement as per the entire area
(concealed/visible) installed. Finished as per satisfaction of E.I.C. PAINTABLE
INSULATION : Providing and fixing thermal insulation with Resin Bonded Fibre glass woolconforming
to IS: 8183 having density 24 kg/m3, 50 mm thick, wrapped in 200G Virgin Polythene Bags fixed to wall
with screw, rawel plug & washers and held in position by criss crossing Gl wire etc. complete as per
directions of Engineer-in-Charge.
Fabrication, Supply & installation of Top mounted SS 304 Grade satin finished railing for staircase area
made by using SS Top rail Ø50x1.5 mm Thk. mounted on SS baluster made of SS round tube baluster
of Ø50 x 1.5 mm thick with SS modular swivel neck to hold the top rail. The total height of the installed
rail including top rail will be 1050 mm from FFL. Further the baluster will be mounted on Dia-100x6 mm
thick SS 304 grade base plate fixed on the Top of the RCC floor with 3 nos. of M10 x 120 mm long
11.14 MR HRD anchors or chemical based anchor. The baluster will hold 5 nos. of SS round tube of Ø16 x 1.5 153.00 Sqm 7000.00 1071000.00
mm thk. as horizontal/diagonal mid rails connected to the baluster with the help of CNC made modular
adjustable connectors. only argon welding allowed at site.The average spacing of baluster will be 900
mm. All material need to be in SS 304 grade with satin finish only.
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50 m x2.00
m made of 40x40x6 mm angle iron or 50x50x3 mm hollow MS tube posts/horizontal members/bracings
covered with 1.63 mm thick MS sheet. The sheet shall be fixed with 30x5 mm MS flat by suitable
welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making
overall height as 2.5 m. MS channel ISLC 75 @ 5.70 kg/m, 50 cm long shall be provided at the bottom
having oval shaped holes of size 50x25 mm at both ends with 50 cm long MS angle 40x40x6 mm
bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by
providing 250 mm long expansion fasteners at both ends. The work shall be executed as per
11.15 16.81 drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic
diversion such as traffic signals during construction at site for day and night, glow lamps, reflective
signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided
shall be retained in position at site continuously including shifting of barricading from one location to
another location as many times as required during the execution of the entire work till its completion.
Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and
works required to execute the job. The barricading shall not be removed without prior approval of
Engineer-in-Charge.
(Note :- One time payment shall be made for providing barricading from start of work till completion of
work including shifting. The barricading provided shall remain to be the property of the contractor on 162.00 metre 3439.50 557199.00
completion of the work).
Contractor 22 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Total aluminium Work : 351258.35 2951956.00
12.00 25.0 STRUCTURE GLAZING WORK
Providing and supplying aluminium extruded tubular and other aluminium sections as per the
architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6
as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of
12.01 25.1 required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material 11198.00 Kgs 414.30 4639331.40
such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work.
Nothing extra shall be paid on this account). The weight of aluminium extruded section shall be taken
for purpose of payment.
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of
12.02 25.2 structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights
and all levels, including
(a) Structural analysis & design and preparation of shop drawings for the specified design loads
conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure
without any failure), including functional design of the aluminum sections for fixing glazing panels of
various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts,
bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)- cum-smoke
seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and
protection against fire hazard including:
(b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of
required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving
perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel
framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent
bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and
in required numbers.
(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone
sealant compatible with the structural silicone sealant of required bite size in a clean and controlled
factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all
of approved grade, brand and manufacture, as per the approved sealant design, within and all around
the perimeter for holding glass
(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes
and profiles, as required as per the site conditions, to seal the gap between the building structure and
all its interfaces with curtain glazing to make it watertight.
(e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it
watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at
bottom (if required), making necessary holes of required sizes and of required numbers etc. complete.
This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium
grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc.,
enabling temporary structures and services, cranes or cradles etc. as described above and as
The item includes the cost of getting all the structural and functional design including shop drawings
checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost
of all mock ups at site, cost of all samples of the individual components for testing in an approved
laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection
till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight
structural glazing having all the performance characteristics etc. all complete as required, as per the
Architectural drawings, as per item description, as specified, as per the approved shop drawings and as
directed by the Engineer- in-Charge.
Contractor 23 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section
capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall
be paid for separately under relevant items under this sub- head. However, for the purpose of payment,
only the actual area of structural glazing (including width of grooves) on the external face shall be
measured in sqm. up to two decimal places.
Note:-2. The following performance test are to be conducted on structural glazing system if area of
structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National
Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies,
India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of
testing on the basis of cost of the work, cost of the test and importance of the work. Performance
Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or any other
accreditation body which operates in accordance with ISO/IEC 17011 and accredits labs as per
1. Performance Laboratory Test for Air Leakage Test (-50pa to - 300pa) & (+50pa to +300pa) as per
ASTM E-283-04 testing method for a range of testing limit 1 to 200 mVhr
2. Static Water Penetration Test. (50pa to 1500pa) as per ASTME- 331-09 testing method for a range
3. Dynamic Water Penetration (50pa to 1500pa) as per AAMA 501.01- 05 testing method for a range
4. Structural Performance Deflection and deformation by static air pressure test (1.5 times design wind
pressure without any failure) as per ASTME-330-10 testing method for a range upto 50 mm
5. Seismic Movement Test (upto 30 mm) as per AAMA 501.4-09 testing method for Qualitative test,
Tests to be conducted on site
6. Onsite Test for Water Leakage for a pressure range 50 kpa to 240 kpa (35psi) upto 2000 ml 1120.00 Sqm 3510.50 3931760.00
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12-
6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified,
comprising of an outer heat strengthened float glass 6 mm thick, of approved colour and shade with
reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear
12.03 25.3 float glass 6 mm thick, spacer tube 12 mm wide, dessicants, including primary seal and secondary seal
(structural silicone sealant) etc. all complete for the required performances, as per the Architectural
drawings, as per the approved shop drawings, as specified and as directed by the Engineerin-Charge.
The IGUs shall be assembled in the factory/ workshop of the glass processor.
(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.25.2) For
payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the
grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.
(i) Coloured tinted float glass 6 mm thick substrate with reflective soft coating on face # 2, + 12 mm
Airgap + 6 mm Heat Strengthened clear Glass of approved make having properties as visible Light
transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20
%, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of
performance glass shall be decided by technical sanctioning authority as per the site requirement.
Extra for openable side / top hung vision glass panels (IGUs) including providing and supplying at site
all accessories and hardwares for the openable panels as specified and of the approved make such as
heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates,
handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all
complete as per the Architectural drawings, as per the approved shop drawings, as specified and as
directed by the Engineer- in-Charge.
Contractor 24 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel
portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi
-rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and
BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface # 1 of the fibre glass
12.05 25.5 insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass 20.00 Sqm 2159.65 43193.00
not less than 60 gm /sqm, made of randomly oriented glass fibres distributed in a binder by a wet-lay
process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board
including SS rivets, nuts, bolts, washers etc complete.
Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic
float glass of approved colour and shade with reflective soft coating on surface # 2 of approved colour
and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for
the required performances as specified, as per the Architectural drawings, as per the approved shop
12.06 25.6 drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area
of glass on face # 1 of the glass panels (but excluding the area of grooves and weather silicone
sealant) provided and fixed in position, shall be measured in sqm. (Payment for fixing of Spandrel
Glass Panels in the curtain glazing is included in cost of relevent Item*).“
(i) Coloured tinted float glass 6 mm thick substrate with reflective soft coating on face # 2, having
properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light
reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . 20.00 Sqm 2450.15 49003.00
The properties of performance glass shall be decided by technical sanctioning authority as per the site
Total Structural Glazing work : 13033835.40 0.00
13.00 22.0 WATER PROOFING
13.01 MR Single component PU +0.3mm PVC Membrane, complying to IS 15909 (Category A, Type 1) 711.00 Sqm 761.00 541071.00
1.2mm Single component PU + 1mm thick PVC Membrane, (Category A, Type IV), complying to IS
15909 on the mother/ RCC slab
13.02 MR Additionally, 2-component acrylic cementitious coating with protection of fiberglass mesh/ fabric over 804.00 Sqm 969.00 779076.00
the insulation/ screed concrete made for required slope/ drainage.
13.03 MR Providing and laying 1.5mm Fully Bonded HDPE membrane, complying to IS 16352 1166.00 Sqm 1453.00 1694198.00
Providing and laying 1.2mm thick HDPE membrane, complying to IS 16352 (for confined retaining
walls) + protection
Providing and applying Swellable Rubber (hydro expensive) for all applications except for Water
Storage Tanks where PVC Centrally Placed Water stops shall be used
Waterproofing of basements and/or other areas as required with 75mm guniting with 1:4 cement sand
mortar to the R.C.C. elements, after cleaning the surface off dust dirt including providing and fixing 100
x 100 x 10G Welded mesh and applying adhesive chemical Conbond SNA as required complete.
a) For Horizontal surface 1120.00 Sqm 969.00 1085280.00
b) For Vertical Surface 1315.00 Sqm 969.00 1274235.00
Total water proofing work : 8082804.00 0.00
14.00 20 PILE WORKS
Boring with hydraulic piling rigs with power units, providing and installing cast in situ single under
reamed piles of specified diameter and length below pile cap in M-25 cement concrete, to carry a safe
14.01 20.3 working load not less than specified, excluding the cost of steel reinforcement but including the cost of
boring with bentonite solution and the length of the pile to be embedded in pile cap etc. all complete.
(Length of pile for payment shall be measured upto to the bottom of pile cap) :
Contractor 25 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading
platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and
dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-
14.02 20.6 charge. Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic method of testing.
Note: 2. Testing agency shall submit the design of loading platform for the approval of Engineer-in-
20.6.1 Single pile upto 50 tonne Safe capacity
20.6.1.1 Initial test (Test Load 2.5 times the Safe capacity) 5.00 per test 54771.50 273857.50
20.6.1.2 Routine test (Test Load 1.5 times the Safe capacity) 5.00 per test 19632.40 98162.00
Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic Echo Test method in accordance
with IS :14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean
14.03 20.9 concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting
the test & submission of results, all complete as per direction of Engineer-in-charge.
Note :- The inclusion of the above item in the schedule of work shall be judiciously decided by the
technical sanctioning authority, keeping in view the quality control, type of soil strata & importance of 216.00 per test 1153.20 249091.20
Providing and fixing permanent steel sheet piles of approved make and section including coating/anti-
14.04 MR corrosive treatment, driving, interlocking, welding, alignment and all incidental works complete as per 1428.00 Sqm 8998.00 12849144.00
specifications.
Total Pile work : 43721930.70 12849144.00
15.00 16.0 ROAD WORK
Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after
excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller
including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth
with lead upto 50 metres.
Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks,
lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by
table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted
15.02 16.91 bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand
bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and
cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete
all as per direction of Engineer-in-Charge.
16.91.2 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 1.00 Sqm 1091.50 1091.50
Construction of granular sub-base by providing close graded Material conforming to specifications,
mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads
15.03 16.78 & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and
compacting with vibratory power roller to achieve the desired density, complete as per specifications
and directions of Engineer-in-Charge.
16.78.3 With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20 95.00 Cum 2808.55 266812.25
Providing and laying at or near ground level factory made kerb stone of M- 25 grade cement concrete in
position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse
sand), including making joints with or without grooves (thickness of joints except at sharp curve shall
not to more than 5mm), including making drainage opening wherever required complete etc. as per
direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment).
(Precast C.C. kerb stone shall be approved by Engineer-in-charge). 16.00 Cum 10117.60 161881.60
Contractor 26 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre
openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall
with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced
barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or
G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced
barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with
tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid
Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including
15.06 16.70 strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction
of Engineer-in- charge.
16.70.1 Made of G.I. wire of dia 4 mm 10.00 sqm 1017.80 10178.00
Providing and laying 500x500x40 mm thick Turf paver (Turfpave XO) on 150 mm thick sub grade of
compacted bed of 20 mm thick nominal size stone aggregate and base course and filling with 150 mm
thick Jamuna sand, including spreading, well ramming, consolidating and finishing smooth etc. all
complete as per direction of Engineer-in-charge.
Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using
cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal
size in appropriate proportions as per approved & specified design criteria, providing dowel bars with
sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using
needle and surface vibrators, levelling to required slope/ camber, finishing with required texture,
including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/
expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine,
providing and filling joints with approved joint filler and sealants, complete all as per direction of
Engineer in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).
Note:- Cement content considered in M-30 is @ 340 kg/cum. Excess/ less cement used as per design
mix is payable/ recoverable separately.
16.43.1 Cement concrete prepared with batch mixing machine 95.00 Cum 10529.35 1000288.25
Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after per cm
making the joints dust free with high pressure air jet cleaners, all complete as per direction of the depth per
15.09 16.45 Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound 316.00 cm width 5.30 1674.80
impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board per metre
and IS: 1834 for hot sealing bitumen compound grade A.) length
Construction of dry lean cement concrete sub base over a prepared sub grade with coarse and fine
aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement
ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content
not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant,
transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne
vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge.
Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road
15.11 16.47 marking paint of superior make as approved by the Engineer-in-charge, including cleaning the surface
of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.
16.47.1 New work (Two or more coats) 48.00 Sqm 188.20 9033.60
Total Road Work: 1927233.35 0.00
16.00 23.0 RAINWATER HARVESTING
Contractor 27 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Supplying, filling, spreading & levelling stone boulders of size range 5 cm to 20 cm, in recharge pit, in
the required thickness, for all leads & lifts, all complete as per direction of Engineer-in
Supplying, filling, spreading & levelling gravels of size range 5 mm to 10 mm, in the recharge pit, over
16.02 23.6 the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of 29.00 Cum 1538.25 44609.25
Engineer-in-charge.
Supplying, filling, spreading & levelling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in
16.03 23.7 required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in- 29.00 Cum 1538.25 44609.25
Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel
16.04 23.8 fine/medium/coarse, in required grading & size as per actual requirement, all complete as per direction 29.00 Cum 2024.50 58710.50
of Engineer-in-charge.
Replacement of M.S. foot rests in manholes including dismantling concrete blocks and fixing with
16.05 19.17 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20
mm nominal size):
19.17.2 With 20x20 mm square bar 156.00 each 621.95 97024.20
16.06 19.19 Providing and fixing in position precast R.C.C. manhole cover and frame.
19.19.3.1 Circular shape 560 mm internal diameter 12.00 each 1675.70 20108.40
Supplying, assembling, lowering and fixing in vertical position in bore well Unplasticised PVC medium
well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings &
accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.
23.4.2 150 mm nominal size dia 240.00 metre 807.45 193788.00
Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and
approved quality
19.19.1.1 Rectangular shape 600x450 mm internal dimensions 12.00 each 1437.65 17251.80
Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in
cement mortar 1 :4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x61 O mm internal
dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and
weight of frame 15 kg), R.C.C. top slab with 1: 1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone
aggregate 20 mm nominal size), foundation concrete 1:5:10 fine sand : 10 graded stone aggregate 40
mm nominal size), inside plastering 12 mm thick with cement mortar 1 : 3 ( 1 cement : 3 coarse sand),
finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per
standard design:
Inside dimensions 455x610 mm and 45 cm deep for single pipe line :
19.30.2 With common burnt clay non-modular bricks of each class designation 7 .5 6.00 each 8150.50 48903.00
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks
and S.W. drain pipe 100 mm diameter, 1.Bm long complete as per standard design.
19.32.1 With common burnt clay non-modular bricks of class designation 7.5 1.00 each 26861.90 26861.90
Total Rainwater Harwesting Work 595650.50 0.00
17.00 MISCELLANEOUS WORK
Contractor 28 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
MODULAR KITCHEN - UNDER COUNTER STORAGE CABINETS:
Providing & fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with
openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked marine ply, all ply
to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and
shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at
least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All
Shutters finished in high gloss acrylic of approved. The cabinet boxes of floor units will be supported by
100mm height vertical adjustable legs which will be covered with PVC skirting in brushed aluminum
finish attached by hardware of skirting. The unit shall be fixed to the floor/ wall/slab using metal screws
of appropriate size and rawl plugs. Only front face area of cabinets and skirting from floor to top of
boxes shall be considered for measurement and payment. Cabinet boxes size would be varies from
400X560X710MM to 1000X560X710MM (approx.) and join together as per site requirements etc.
MODULAR KITCHEN - OVERHEAD STORAGE WALL UNITS:
Providing & fixing factory made modular kitchen cabinets in modular type knockable cabinet boxes with
openable shutters and sufficient number of drawers made of 18 mm thk. ISI Marked marine ply. All ply
to be laminated with 0.8 mm laminate.All shelves should be supported on approved quality SS pins and
shall be adjustable for different heights as per requirements.Shutters and drawers fascia shall be at
17.02 MR least 18mm thic with laminate on both sides with 18mm wide 2mm thick PVC edge banding, All 7.00 Sqm 8643.00 60501.00
Shutters finished in high gloss acrylic of approved. The unit shall be fixed to the floor/ wall/slab using
metal screws of appropriate size and raw plugs. Only front face area of cabinets and skirting from floor
to top of boxes shall be considered for measurement and payment. Cabinet boxes size would be
varies from 400x560x710MM to 1000x560x710MM (approx.) and join together as per site requirements
17.03 MR Providing and fixing of Innotech with metal sides and quadro channels 20.00 Each 3833.00 76660.00
17.04 MR Providing and fixing of Innotech with metal sides and quadro channels 20.00 Each 4336.00 86720.00
SLIDING & FOLDING ACOUSTIC PARTITION : Supply & installation of Zilio Lite system of the sliding
folding partition type with the following details. Top rail/track: top rail/track shall be proprietary supplied
extruded aluminum Profile, finished in approved color anodized finish. Above fixed Mild Steel support
Structure: Mild Steel partition above sliding folding panels with 50mm thick rockwool insulation based
on the Acoustics required,finish for above support: gypsum cladding shall be provided with necessary
cut-outs for services, Mild Steel structure shall be created with the help of Anchor fastners,Box/square
Mild Steel pipes attached to the true slab. Moveable partition Panels : Panels to be filled with
necessary infills for acheiving the necessary nrc levels, finished on both sides with MDF, the panels will
have retractable Top and Bottom acoustical seals for better acoustics.Panel Mounting: panels shall be
mounted over proprietary supplied Zilio Aluminium & Mild Steel, frame work as per Architect/Clients
17.05 MR requirement.Suspension :The partition panels shall be suspended on track/rails with the help of top 0.00 Sqm 49834.00 0.00
hung mechanism.The top rail shall be fixed/suspended from the Mild Steel structure using threaded
rods. Quote also to include necessary supports, cutting, finishing for the sliding folding partition panel
top rail. Parking/Stacking module: the partition panels shall be centre/parallel/side stackable type as per
client's requirement. Retractable Operation/Mechanism - Manual Handle operation by an Internal crank
jack spindle mechanism. Telescopic panel - Manual handle operation by two different internal crank
jack mechanism with lever closer cut teeth gear.
ZILIO ZM - W100 Lite - Manual Suspension : 1,Track : 300.001.004,Sound Rating : 46dB,No. of
Panels - 8, Total Width : 9800mm,Clear Height : 2550 mm,True Celing Height : NA,Parking Layout :
Type A Center stacking,Surface : Laminate Finish
Contractor 29 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
ACCESS PANEL: Providing & fixing Access Panel of size mentioned below having - 1. Outer
aluminium frame - thickness : 1.5mm (plus 0.2mm thick powder coating) Material : ENAW6063. 2.
Inner Aluminium frame - thickness: 1.5mm (plus 0.2mm thick powder coating) Material : ENAW6063. 3.
Corner fittings, inner frame - material: Hot dipped galvanized steel plate Thickness 2.0mm, with zinc
Coating of 200g. 4. Corner fittings, outer frame - material: Hot dipped galvanized steel plate Thickness
2.0mm, with zinc Coating of 200g. 5. 12mm plasterboard (Knauf Brand) Type: moisture resistant (MR)
in green plasterboard liner. 6. Screw (self-drilling black phosphate) - Material: mild steel C1018 - 1022.
7. Sealing strip, width, thickness - width: 9.0mm, thickness: 4.0mm. 8. Snap Lock (spring catch/ catch
lock) - Type of lock: touch latch, Material of lock: plastic ABS, cold rolled steel Q235. 9. Hinge -
Thickness : 4.0mm, Length: 82mm; Material: SS2172 (cold drawn steel wire). 10. Powder coating -
Color: white, RAL 9010
BLINDS : Providing & Fixing of Window Blinds as per the approved sample double honeycomb shades
having honeycomb within honeycomb with easy rise operating system as per following specifications
fabric specifications:
• Original Non-woven honeycomb shade shaving soft fabric appearance and high energy-efficient fabric
with high tear strength constructed out of Anti-static, resilent, colour fast & Sanitized Treat 100% spun
bonded non-woven polyester fiber & precision manufacture to form a hexagonally shaped duette pleat.
The Fabric is GREENGUARD certified and can attain an NRC value of 0.75. Certificates to be provided
at the time of delivery of material at site. Pleat dimension ¾ ”Honeycomb within a Honeycomb” with 3
air pockets for maximum energy efficiency.
• Shadings are duotone, with neutral tone facing the exterior and color facing the interior The Head rail.
Shall measure 50 wide and 35mm deep & thick 1.25mm extruded from alu. alloy& shall be powder
coated to a smooth finish with a thickness of 40 microns. Fabric shall be constructed from spun-bonded
polyester fiber, precision manufactured to form a hexagonally shaped, dual pleat, cellular construction.
17.07 MR All cords & cord holes shall be fully concealed inside the fabric structure. As each of the hexagonal cells 139.76 Sqm 20764.00 2902018.17
is formed individually, pleats operate independent of each other providing superior pleat retention &
structure strength. Installation brackets. shall be of high-tension spring steel suitable for overhead &
wall mounting 30mm Duette Hartford mounting bracket. Head rail covered with Sydney Valance of
height 80mm made up of Aluminium & L shape moving Rail includes “Click & Engage" method of
dimension 50mmx55mmsticked with integrated moving rail magnets provide a streamlined look, reduce
centre light gap, and promote easier operation. Polyester cord. Shall be 0.9mm in diameter & of woven
hollow core end cap shall be moulded acrylic color matched to the head & bottom rails. Bottom rail shall
be a single channel section, measuring 30mm wide and 12.5mmdeep & thickness 1-1.2mm extruded
from alu. Alloy & shall be powder coated with a smooth finish to a thickness of 15-25 microns. Hold-
Down bracket (optional) shall be molded in clear acrylic. It incorporates a pin for engagement with the
bottom rail end-cap. It shall be suitable for sill, face or side facing. Cord Equalizer shall be injection
melded from impact modified acrylic with a high flexural modulus
Contractor 30 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: CIVIL
DSR 2023/ Amount
S No MR ITEMS Description of Item Qty Unit Rate DSR NON DSR
All Figures are in Rs. All Figures are in Rs.
Providing & supplying of Window Blinds as per the approved sample in required shade and style
consisting, of Roller Blinds comprising of optima screen Fabric comprising of 22% polyester, 78% PVC,
Fabric weight 460-480G weight per sqm, Thickness 0.67 mm, Yarn count 18-19/cm, having fire
resistance standard – NFPA 701-89 small testing ISO-5659-2. The tear resistance should be complying
to ISO4674 & breaking resistance – ISO 5081. The DRIVE UNIT shall be of clutch for quick, easy and
safe installation, molded plastic with steel spring support and inserted into the tube end. It shall be
driven by a ball chain pulley with ball chain and can be positioned at right side or left-hand side of the
Shade. The Shade when lowering or raising, shall be automatically locked in position upon release of
the ball chain by means of a built-in friction lock. Universal clutch for left- and right-hand operation.
Chain Gear Ratio of 1.75:1. The END PLUG shall be molded of plastic with a steel location pin. The
17.08 MR plug shall be inserted into the tube end. (Opposite to the Drive Unit) for ease of installation. The 559.05 Sqm 2907.00 1625152.54
SUPPORT BRACKETS shall be of coated steel & provided with covers and used in right hand or left-
hand positions differentiated by the acceptance of the of the rectangular drive unit support or the round
idler plug pin. Can be installed (a) On Face (b) Ceiling Mount (c) On Frame (d) in Recess. The Bracket
should be protruding outside maximum of 80mm.The ROLLER TUBE shall be of extruded aluminium
with 37mm internal diameter & skin thickness of 1mm and shall incorporate a keyway integral with the
tube to accommodate the spline. The BOTTOM RAIL shall be a Flat Bottom made up of powder coated
steel. The BALLCHAIN shall be 2mm diameter cord with 4.5mm diameter acetal balls molded co-axially
to it on 6mm pitch to form an endless ball chain. It is used for raising or lowering action of the shades.
Total Miscellaneous Work 0.00 5755243.70
Contractor 31 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
A POINT WIRING
Wiring for light point/ fan point/ exhaust fan point/ call bell point with
1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core
cable in surface/ recessed medium class PVC conduit, with modular
A.1 switch, modular plate, suitable GI box and earthing the point with 1.5
sq.mm FRLS/HFFR PVC insulated copper conductor single core
cable etc. as required
Wiring for group controlled (looped) light point/fan point/exhaust fan
point/ call bell point ( without independent switch etc.) with 1.5 sq.
mm FRLS/HFFR PVC insulated copper conductor single core cable
1.55 in surface/ recessed PVC conduit, and earthing the point with 1.5 sq.
mm FRLS/HFFR PVC insulated copper conductor single core cable
etc. as required.
Wiring for light/ power plug with 2X4 sq. mm FRLS/HFFR PVC
insulated copper conductor single core cable in surface/ recessed
A.3 1.12 medium class PVC conduit along with 1 No. 4 sq. mm FRLS/HFFR Metre 16290 373.00
PVC insulated copper conductor single core cable for loop earthing
as required. 6076170.00
Supplying and fixing following modular switch/ socket on the existing
1.24 modular plate & switch box including connections but excluding
modular plate etc. as required.
1.24.4 3 pin 5/6 amp socket outlet Each 2 136.00 272.00
1.24.5 6 pin 15/16 amp socket outlet Each 2 219.00 438.00
Supplying and fixing modular blanking plate on the existing modular
A.5 1.26 plate & switch box excluding modular plate as required. Each 25 47.00
Supplying and fixing following size/ modules, GI box along with
1.27 modular base & cover plate for modular switches in recess etc. as
Wiring for twin control light point with 1.5 sq.mm FRLS/HFFR PVC
insulated copper conductor single core cable in surface / recessed
medium class PVC conduit, 2way modular switch, modular plate,
suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR
PVC insulated copper conductor single core cable etc. as required.
Contractor 32 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and fixing 3
pin 5/6 A modular socket outlet and 5/6 A modular switch,
connections etc. as required. 182575.00
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and fixing 6
pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,
connections etc. as required. 104122.00
Supplying and fixing suitable size GI box with modular plate and
cover in front on surface or in recess, including providing and fixing 2
A.10 1.56 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular Each 145 757.00
switch, connections etc. as required. (For light plugs to be used in
non residential buildings). 109765.00
Supplying & fixing suitable size GI box with modular plate and cover
in front on surface or in recess including providing and fixing 25 A
modular socket outlet and 25 A modular SP MCB, "C" curve
including connections, painting etc. as required. 807.00
B SUBMAIN AND CONTROL WIRING
Wiring for circuit/ submain wiring along with earth wire with the
following sizes of FRLS/HFFR PVC insulated copper conductor,
single core cable in surface/ recessed medium class PVC conduit as
1.14.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire Metre 10 373.00 3730.00
1.14.4 2 X 6 sq. mm + 1 X 6 sq. mm earth wire Metre 200 482.00 96400.00
1.14.10 4 X 10 sq. mm + 2 X 6 sq. mm earth wire Metre 360 1078.00 388080.00
1.14.11 4 X 16 sq. mm + 2 X 6 sq. mm earth wire Metre 360 1454.00 523440.00
Supplying and making end termination with brass compression gland
and aluminium lugs for following size of PVC insulated and PVC
sheathed / XLPE aluminium conductor cable of 1.1 KV grade as
Supply of following XPLE armourned 1.1 KV grade conforming to
I.S.7098/1554Aluminium Conductor Cables :
Supply of following sizes of PVC sheathed PVC/XLPE insulated
Aluminium conductor armoured cable of 1.1 KV grade conforming to
IS:7098 part-1 / IS:1554 part-1 respectively & ISI marked.
Contractor 33 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
(b) 3.5 C x 95 Sqmm XLPE cable RM 100 1080.00 107999.81
(c ) 3.5 C x 70 Sqmm XLPE cable RM 50 849.95 42497.26
(d) 3.5 C x 50 Sqmm XLPE cable RM 50 637.50 31875.02
(e) 3.5 C x 35 Sqmm XLPE cable RM 50 475.26 23763.17
(g) 4 C x 16 Sqmm XLPE cable RM 200 262.50 52500.04
Supply of following sizes of copper cables -PVC sheathed
PVC/XLPE insulated Copper conductor armoured cable of 1.1 KV
grade conforming to IS:7098 part-1 / IS:1554 part-1 respectively &
(a) 4 C x 16 Sqmm XLPE copper cable RM 250 1807.50 451876.04
(b) 4 C x 25 Sqmm XLPE copper cable RM 100 2816.25 281625.35
(c ) 3.5 C x 35 Sqmm XLPE copper cable RM 50 3357.51 167875.27
(d) 3.5 C x 50 Sqmm XLPE copper cable RM 50 4030.00 201500.02
Laying of one number PVC insulated and PVC sheathed / XLPE
power cable of 1.1 KV grade of following size direct in ground
including excavation, sand cushioning, protective covering and
refilling the trench etc as required.
10.1.2 Above 35 sq. mm and upto 95 sq. mm Meter 100 475.00 47500.00
10.1.3 Above 95 sq. mm and upto 185 sq. mm Meter 100 497.00 49700.00
10.1.4 Above 185 sq. mm and upto 400 sq. mm Meter 200 564.00 112800.00
Supplying and fixing single pole blanking plate in the existing MCB
DB complete etc. as required. 1400.00
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C"
curve, miniature circuit breaker suitable for inductive load of following
D.2 poles in the existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, MCB in the
MR existing MCB DB complete with connections, testing and
commissioning etc. as required.
Supplying and fixing following way, horizontal type three pole and
neutral, sheet steel, MCB distribution board, 415 V, on surface/
recess, complete with tinned copper bus bar, neutral bus bar, earth
bar, din bar, interconnections, powder painted including earthing etc.
as required. (But without MCB/ RCCB/ Isolator)
MR 12 way (4 + 36), Double door Each 20 9081.00 181620.00
Supplying and fixing following rating, double pole, (single phase and
neutral), 240 V, residual current circuit breaker (RCCB), having a
2.14 sensitivity current 30 mA in the existing MCB DB complete with
D.5 connections, testing and commissioning etc. as required.
Contractor 34 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Supplying and fixing following way, single pole and neutral, sheet
steel, MCB distribution board, 240 V, on surface/ recess, complete
D.6 2.3 with tinned copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including earthing etc. as required.
(But without MCB/RCCB/Isolator)
2.3.3 12 way, double door Each 7 2871.00 20097.00
PROVISIONS FOR VOICE, DATA, SECURITY & TV SYSTEMS
Supplying and fixing following modular switch / socket on the existing
1.24 modular plate & switch box including connections but excluding
E.1 modular plate etc. as required.
1.24.6 Telephone socket outlet Set 119 168.00 19992.00
1.24.7 TV antenna socket outlet Set 31 168.00 5208.00
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid
copper conductor PE insulated, shielded with fine tinned copper
braid and protected with PVC sheath in the exisitng surface/recessed
steel/ PVC conduit as required 50220.00
Supplying and fixing of following sizes of medium class PVC conduit
along with accessories in surface/recess including cutting the wall
E.3 and making good the same in case of recessed conduit as required.
Supplying and drawing following pair 0.5 mm dia FRLS/HFFR PVC
insulated annealed copper conductor, unarmored telephone cable in
the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing two module stepped type electronic fan
regulator on the existing modular plate switch box including
connections but excluding
modular plate etc. as required. 10452.00
Installation, Testing and Commissioning of ceiling fan, including
wiring the down rods of standard length (upto 30 cm) with 1.5 sq.
E.6 1.45 mm FRLS/HFFR PVC insulated, copper conductor, single core Each 26 332.00
cable, including providing and fixing phenolic laminated sheet cover
on the fan box etc. as required. 8632.00
Installation, Testing and Commissioning of exhaust fan in the
E.7 1.50 existing opening, including making good the damage, connection,
testing, commissioning etc. as required.
Extra for fixing the louvers/ shutters complete with frame for a
1.51 exhaust fan of all sizes. 5720.00
Contractor 35 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Brush Less Direct Current (BLDC) Fan with Remote
Supply, Installation, Testing and Commissioning of ceiling fan with
Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3
nos. metal(Aluminium alloy) blades, 30 cm long down rod, 2 nos.
canopies, shackle kit, safety rope, copper winding, steel/Al body.
Power Factor not less than 0.9, Service Value (CM/M/W) minimum
as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total
Harmonic Distortion)
E.9 9.1 less than 10%, remote (preferably mobile app based) for speed
control and all remaining accessories including safety pin, nut bolts,
washers, temperature rise=75 0C (max.), insulation resistance more
than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply
Ceiling Fan compliant to IS 374:2019 fan i/c external connections
with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single
and earthing etc. as required.
9.1.3 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
E.10 MR Supply of Exhaust Fan 300 mm Each 22 3500.00 77000.00
Providing and fixing M.S. Fan clamps of 16 mm dia M.S. bar, bent to
shape with Hooked ends in R.C.C. slabs or beams during laying,
including painting the exposed portion of loop, all as per standard
design complete
Providing and fixing circular/Hexagonal G.I. Box for ceiling fan
clamps, of internal dia 140 mm, 73 mm height, top LID of 1.5 mm
thick G.I. sheet with its top surface hacked for proper bonding, top
E.12 DSR 10.18LID shall be screwed into the G.I. box by means of 3.3 mm dia Each 26 220.65
rounded screws, one lock at the corners. Clamps shall be made of
12 mm dia M.S. bar bent to shap as per standard drawing.
Supply, Installation, Testing and Commisioning of Galavanized Iron
(GI) Raceways along with required suitable number of GI couplers
MR for joining raceways and fixing GI brackets and all accessories
complete in all respect as per the directions of engineer in charge
E.14 (a) 300mmx38mm(GI) - 3 compartment Mtr 100 2172.50 217249.61
(b) 225mmx38mm(GI) - 3 compartment Mtr 80 1775.00 142000.11
Supply, Installation, Testing and Commisioning of Junction boxes for
direct access to cables at the intersection of raceways supplied
completely with base and cover plates, height adjustable junction
box 65- 90 mm including all accessories ss plate of 3mm thick
E.15 complete in all respect as per the directions of engineer in charge
Contractor 36 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick
including accessories, and providing masonry enclosure with cover
plate having locking arrangement and watering pipe of 2.7 Meter
long etc. with charcoal/ coke and salt as required. 100212.00
Providing and fixing 25 mm X 5 mm copper strip on surface or in
recess for connections etc. as required. 124600.00
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess
for connections etc. as required. 28700.00
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for
loop earthing as required. 16800.00
Providing and fixing of lightning conductor finial, made of 25 mm dia
300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6
mm thick G.I. base plate including holes etc. complete as required.
F.6 6.2 Fixing of lightning conductor finial (single prong) with base plate includingEach
holes etc. complete
4 as required.
Jointing copper / G.I. tape (with another copper/ G I tape, base of the
F.7 6.3 finial or any other metallic object) by riveting / nut bolting/ sweating Each 4 139.00
and soldering etc as required. 1112.00
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or
F.8 6.6 surface of wall for lightning conductor complete as required.(For Meter 150 148.00
horizontal run) 47360.00
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or
F.9 6.70 surface of wall for lightning conductor complete as required.(For Meter 150 238.00
vertical run) 76160.00
G PANEL BOARDS
Designing, fabricating, transporting, unloading, storing, fixing in
position, testing and commissioning the following sheet steel cubicle
type panels fabricated from 1.6mm thick CRCA sheet, dust and
vermin proof, outdoor type double door with canopy, TPN Panels
with hinged lockable doors fabricated from 2mm thick CRCA sheet,
suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear access
for cable alley and with segregated bus-bar chamber with tinned
aluminium bus bar and including supplying and fixing following
switchgears, meters and accessories, inter-connections, bonding to
earth, powder coated painting and marking as specified. Switch
boards complete as per schematic diagram:
Contractor 37 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Type of construction: Form 3
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Schematic diagram and as detailed in the Specifications
Colour: Gray Powder Coated, as per approved sample.
1 nos, 630 Amps. 4 pole MCCB , i.e four pole Moulded Case Circuit
Breaker of fault breaking capacity 25 KA (ICS=ICU up to 433 V)
complete in all respect
TPN aluminum bus bars of minimum of 800 Amps capacity with heat
shrinkable colored sleeves and I/C DMC/SMC bus bars supports at
required intervals complete for cross section, size supports & their
spacing etc. for withstanding fault level of 25 MVA for 1 Sec.
(a) 63 Amps, TPN, MCB +ELCB - 20 Nos.
(b) 40 Amps, TPN, MCB +ELCB - 10 nos
Panel complete as above Each 1 425000 425000.00
G PANEL BOARDS
Contractor 38 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Designing, fabricating, transporting, unloading, storing, fixing in
position, testing and commissioning the following sheet steel cubicle
type panels fabricated from 1.6mm thick CRCA sheet, dust and
vermin proof, outdoor type double door with canopy, TPN Panels
with hinged lockable doors fabricated from 2mm thick CRCA sheet,
suitable for 415V, 3 phase 4 wire 50Hz AC supply with rear access
for cable alley and with segregated bus-bar chamber with tinned
aluminium bus bar and including supplying and fixing following
switchgears, meters and accessories, inter-connections, bonding to
earth, powder coated painting and marking as specified. Switch
boards complete as per schematic diagram:
Type of construction: Form 3
IP classification: 42
The LT PANEL shall be electrically inter-locked as shown in
Schematic diagram and as detailed in the Specifications
Colour: Gray Powder Coated, as per approved sample.
1 nos, 200 Amps. 4 pole MCCB , i.e four pole Moulded Case Circuit
Breaker of fault breaking capacity 25 KA (ICS=ICU up to 433 V)
complete in all respect
TPN aluminum bus bars of minimum of 250 Amps capacity with heat
shrinkable colored sleeves and I/C DMC/SMC bus bars supports at
required intervals complete for cross section, size supports & their
spacing etc. for withstanding fault level of 25 MVA for 1 Sec.
(a) 63 Amps, TPN, MCB - 4 Nos.
(b) 40 Amps, TPN, MCB - 4 nos
Panel complete as above Each 7 225000.00 1575000.00
H SAFETY ITEMS
Providing and fixing MV danger notice plate of 200mm x 150mm
made of mild steel, atleast 2 mm thick, and vitreos enamelled white
on both sides and with iscription in single red colour on front side as
Online UPS- Input supply: Three Phase, Output supply: Three
Phase- Supplying, installation, Testing & Commissioning of following
a 26.2.3 capacity at fullPower
30KVA (Each load (Unity
operating temperature 0 Nos. 2 505748.00 1,011,496.00
Contractor 39 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Supplying,installation,testing and commissioning of 6 meter
Height hot dipped galvanized pole continously tapered (bolt
fixing type) octagonal Pole with top 70 mm dia and bottom 130
mm dia made of 3 mm thick H T sheet Steel conforming to grade
S 355 complete with G I base plate of size 220 mm (L) X 220
mm (B) X 16 mm thickness welded at bottom of pole complete with
4 Nos 20 mm dia 600 mm long foundation bolts confroming
to EN 8 grade, inbuilt / Vandal resistance, weathproof
electrical junction box having terminal block, 32A 4P MCB in
incomer & 16A DP MCB in outgoing for Pole Light ON/ OFF
etc mounted on bakelite sheet for looping in /looping out of
cables, with flush door having locking arrangement,
earthing arrangement (at atleast 0.5 m height) and
mounted on RCC foundation of size 500 mm x 500 mm x
1200 mm in ground and 300 mm above ground level with
foundation bolt duly embeded before casting and supply and
embedding of suitable size HDPE pipe sleeve for cable entry.
complete including erection of Pole complete in all respect as
per specification as reqd.
Supply, Installation, testing and commissioning of 500mm
long Single arm bracket of approved design and shape
H.4 NS/MR made up of MS metal with hot dip galvanised suitable Each 15 2000.00 30000.00
for pole top of 70mm dia complete with fixing arrangement as
Supplying & drawing 3x2.5sq.mm size FR PVC insulated copper
H.5 NS/MR conductor single core cable in the existing pipe as required Meter 150 400.00 60000.00
Supplying, installation on wall, testing and commissioning of
following capacity Air Insulated Compact Type Rising Mains for use
wire 415 volts, 50Hz A.C. supply with enclosure having IP-54 rating
after fixing the tap off boxes and all accessories, made of 1.6mm
thick steel sheet duly powder coated in convenient sections complete
I.1 3.8 with 4 Nos aluminium bus bars having current density of 130 A/ sq
cm at nominal current rating, necessary joints & expansion joints, fire
barrier at each floor, provision of tapping at every metre, continuous
earthing with 2 Nos aluminium strip of suitable size (one on each
side) including, G.I. clamping brackets, angle iron bracket, steel
fasteners, connecting to earthing system etc. as required.
Contractor 40 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - ELECTRICAL WORKS
S NO E&M DESCRIPTION UNIT QTY RATE
2025 All Figure are in Rs. All Figure are in Rs.
Supplying, installation, testing & commissioning of following capacity
End Feed Unit for the existing Air Insulated Compact Type bus
trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C.
supply made with 1.6mm thick steel sheet enclosure (IP54) duly
I.2 3.11 powder coated with provision of MCCB/ACB (but without
MCCB/ACB) complete with necessary joints including clamping
brackets, angle iron bracket, steel fasteners, connecting to earthing
system etc. as required
Supplying, installation, testing & commissioning of following capacity
Plug In/ tap off box on the existing Air Insulated Compact Type bus
trunking/ rising mains for use on 3 phase 4 wire 415 volts, 50Hz A.C.
I.3 3.12 supply made with 1.6mm thick sheet steel enclosure (IP54) duly
powder coated with provision of MCCB/ACB (but without
MCCB/ACB) complete etc. as required
Total of Electrical items 14667783.90 5850683.35
Contractor 41 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
Supply, installation, testing and commissioning of following capacity (continuous loading) 11/0.433 KV Delta/Star,step down, 3 Phase, 50 Hz, Dyn 11 vector
group, Cast Resin / VPI (vacuum pressure impregnated) Dry Type, copper wound transformer (Electrolytic grade 99.9% pure copper, Core made of first grade
Cold Rolled Grain Oriented (CRGO) Core grade MOH or better) AN (air natural) cooled transformer suitable for indoor applications with Offload Tap Changer/ On
Load Tap Changer (OLTC) (upto 500 KVA offload and above 500 KVA On Load Tap Changer) on HV side having AVR relay and Remote Tap Changer Control
(RTCC) for automatic sensing of incoming voltage, automatic operation of OLTC and facility for remote and manual operation of OLTC HV side in range of +5% to
-15% in steps of 2.5%, insulation class F (minimum), suitable for environment conditions class E4, suitable for fire behaviour class F1,climate class-C1, having
cable end boxes on HV side suitable for 3x300 sqmm XLPE cable of 11 KV grade with necessary hardware, clamps, lugs etc. for termination on HV/MV etc. for all
transformers, bus trunking arrangement on LV side complete with all accessories and safety provisions as per relevant IS Code ,The transformer shall be
provided with standard fittings/ accessories as per relevant IS and mentioned below, protection alarm/trip protection, 3 nos. of Polymeric Zinc Oxide surge
Arrestors on HV Side. Winding Temperature scanner (Digital) with alarm/Trip contacts with RTD Sensors per LV winding and space for mounting differential
protection CT's in LV chamber with neutral brought out separately including supplying and laying of copper conductor multicore control cable from transformer to
24.27 1 HT breaker/HT Panel for safety tripping, complete as confirming to IS-2026 Part-11, i/c supplying and grouting of suitable M.S. Channel with all accessories
,complete in all respects as required at site as per CPWD specifications . Design ambient condition : a) air temperature 50 0C, b) Relative Humidity 90 % Max, c)
Seismic Zone as per location of site, d) Altitude as per location/site. The transformer should have QR code which should contain drawing, test report OEM manual,
Geo- Tag of manufacturing location, rating plate as per relevant IS Code etc. All testing shall as per relevant IS Code. Noise level shall not exceed limits as per
NEMA TR-1 with all accessories running measured as per IEC 551/ NEMA Standard.
Fitting and Accessories : The following fittings shall be provided:- a) Two earthing terminals with the earthing symbol b) Rating and terminal marking plates; c)
Thermometer pocket with cap; d) Lifting lugs for the complete transformer as well as for core and winding assembly; e) Bi-directional flat rollers (for transformers
above 200 kVA); f) HV side neutral grounding strip (where one of the HV bushing terminal is connected to earth); g) Arcing horns or suitable rating lightning
arrestors for HT side – 3 Nos. for transformers up to 200 kVA; h) Bird guard; i) Jacking pads (for transformer above 1 600 kVA); j) Name Rating & Diagram Plate.
k) Monogram Plate.i) Additional neutral separately brought out on bushing for earthing. Level 5
24.27.37 1.1 630 KVA (losses at 50% loading < 1745watt, losses at 100% loading < 4850watt) 1 Each 1904199.00 1904199.00
25.1 2 Automatic Power Factor Correction (APFC) System
Automatic Power Factor Correction (APFC) System Supply, Installation, testing and commissioning of Automatic Power Factor Correction (APFC) panel, indoor type floor
mounted free standing totally enclosed, extendable, IP 42, of following capacity for 3 phase, 415 V + 10 %, 50 Hz AC System for Ambient temperature -5°C to +40°C, fabricated
in compartmentalised designed made of CRCA sheet steel of 2.0mm thick for framework & covers, 3 mm thick for gland plate i/c cleaning & finishing complete with 9 tank process
for powder coated of approved shade ( RAL 7032-Siemens Gray or as approved by Engineer-in-Charge), having front section (switch gear and control accessories) and rear
section capacitor and reactor, front and rear access, having suitable current carrying capacity, extensible TPN Aluminium alloy bus bar of high conductivity, DMC/SMC bus bar
supports, bottom base channel of MS Section, fabrication shall be done in transportable section, entire panel shall have common copper earth bar of minimum size of 25mm x
5mm with 2 nos. earth studs, the earth terminals provided on the body of capacitor bank shall also be bonded to the main capacitor panel earth bus with 2 nos. 8 SWG or 6 SWG
GI earth wires/ equivalent size of copper conductor cable, forced ventilation for maintaining temperature rise not more than 5°C from ambient, interconnections, connections with
14% detuned reactor and heavy duty 525 V ISI marked Impregnated MPP(Metalized Polypropylene) Capacitor (IS 13340 Part -1 & 2) APFC Panel shall be in compliance with IS
:16636 & CPWD Specifications etc. as per below details.
(A) Incomers Suitable capacity MCCB Microprocessor base with O/C, S/C, E/L release of TPN 50KA breaking capacity (Ics=Icu), ON, OFF, Trip, R, Y, B - LED Indicating Lamp
set along with required Instruments and accessories with extended rotary handle and door interlocking arrangement. Current rating of the Incomer in ampere shall be APFC
Panel rating in KVAR x 1.4 x 1.5 or Nearest higher standards rating.
(B) Instruments & Indications i) 3-Phase current sensing APFC microprocessor relay/controller, advance 8/12 stages (8 stages for capacity below 100 KVAR and 12 stages 100
KVAR & above) with Communication Ethernet/RS485/SNMP port open protocol for BMS integration as per approved by Engineering in charge and having display of Phase wise
V, A, PF, Cos-Phi, Kw, KVA, KVAR, THD-V, THD-I, harmonics up to 31 level. 3 nos of dual core CT's accuracy class 1, 15VA at incomer of PCC Panel for APFC relay.
ii) Auto Manual Selector switch, auxiliary contactors with timer for delay in manual mode.
iii) Digital Multi function meter with LED Display for V, A, PF, KW, KVA, KVAR, THD-V & I, Frequency.
iv) Suitable rating control transformer shall be provided for control and indication circuit.
v) All components like control transformer, meter, relay and indicating lamp shall be protected by using suitable rating individual MCB's.
vi) Wiring of the control circuit shall be done by using 2.5 sq mm, FRLS/HFFR 1100 V grade, PVC insulated multi stranded copper control wire.
(C) Bus Bars 1.3 Amp per Sq.mm,TPN, Electrolytic grade Aluminium bus bar of capacity 1.25 times of incomer rating as per CPWD specification.
(D) Outgoings (APFC Section) Selection of the capacitors combinations shall be for continuous rating and each capacitor bank shall have suitable capacity Heavy
Duty ISI Marked Capacitor, capacitor duty contactor,the capacitor shall be mounted on channel with base of perforated M S Powder coated sheet, connections
inter connections etc. and other features as per CPWD Specifications and relevant IS Code having following:
(i) Capacitor bank ratings & stages shall be as per the technical specifications sheet of NIT.
(ii) Capacitor will be MPP self healing type with discharge resistor, pressure release mechanism.
(iii) Since Capacitor Voltage is 525 Volts, thus higher KVAR has to be considered to get rated output at 415 Volts.
(iv) 14% Detuned Reactor of class H insulation & 150% linearity in series with Capacitor.
(Note: Technical specifications sheet for selection of the capacitors combinations shall be provided by the NIT Approving Authority with due consideration of
number of capacitors i.e. 1 KVAR, 2 KVAR, 3 KVAR, 5 KVAR, 10 KVAR.....for smooth correction).
Contractor 42 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
Supplying, Installation, Testing & Commissioning of ‘Silent Type Diesel Generating set as per CPCB IV + or better norms along with having Prime Power Rating
of KVA as below, 415 volts at 1500 RPM, 0.8 lagging power factor at 415 V suitable for 50 Hz, 3 phase system & for 0.85 Load Factor, including testing at factory
and site with fuel, load for test and other necessary arrangements Complete as per CPWD specifications, should have QR code which should contain drawing,
test report OEM manual,Geo- Tag of
manufacturing location, rating plate as per relevant IS Code etc. and consisting of the followings:
(A) Diesel Engine: Tourbocharged Diesel engine 4 stroke water cooled, multi cylinder, dynamically balanced fly wheel, electric
start of suitable BHP at 1500 RPM suitable for above output of alternator at 40 0C, 50% RH & at 1000 Meter MSL , capable of taking 10% over loading for one
hour after 12 hours of continuous operation. The engine will be with Electronic governor, Dry type Air filter with
service indicator, first filling of engine fuel (after commissioning) lubricating Oil, Coolant and other consumables complete with all the required accessories, the
Electronic governor shall be as per ISO 8528.The engine shall comply to the latest CPCB norms (CPCB IV + or better) and Conforming to BS 5514, BS 649, IS
10000, IS 10002, IS 13018 and as per CPWD specifications.
(B) Engine mounted Instrument Panel fitted with and having digital dis Plate for following:
(i) Start-stop switch with key
(ii) Water temperature indication
(iii) Lubrication oil pressure indication
(iv) Lubrication oil temperature indication
(v) Battery charging indication and Voltage indication
(vi) RPM indication
(vii) Over speed indication
(viii) Low lubricantion Oil trip indication
(ix) Engine Running Hours indication
(C) Alternator: Synchronous alternator rated of appropriate KVA, 415 volts at 1500 RPM, 3 phase 50 Hz, AC supply with 0.8 lagging power factor at 40 0C, 50%
RH & at 1000 Meter MSL. The alternator shall be having Screen Protected Drip Proof (SPDP) enclosure IP23, brushless, continuous duty, dynamically balanced
rotor, capable of taking 10% over loading for one hour after 12 hours of continuous operation, self cooled,self-excited and self-regulated through AVR conforming
to IS13364(Part 2)/IS: 4722/BS 2613 suitable for tropical conditions and with class- H insulation.
(D) Base Frame & Foundation: Both the engine and alternator shall be mounted on suitable base frame made of MS channel with necessary reinforcement which
shall be installed on suitable cement concrete foundation and vibration isolation arrangement as per recommendations of manufacturer.
(E) FUEL TANK: Daily service fuel tank of suitable liters capacity as per CPWD Specifications, fabricated out of 3 mm thick M.S. sheet complete with all standard
accessories and fuel piping between fuel tank and diesel engine with MS class ‘C’ pipes of suitable dia. Complete with valves, level indications & accessories as
required as per specifications.
(F) Exhaust System: Dry exhaust manifold with hospital type exhaust silencer and catalytic convertor.
(G) Starting System: 12V/24V DC starting system comprising of starter motors: voltage regulator and arrangement for initial
excitation complete with suitable numbers of batteries (180 AH capacity lead acid SMF type) as required as per specifications. The battery shall be housed inside
the acoustic enclosure of DG Set.(H) Acoustic and weather proof enclosure with arrangement for fresh air intake for cooling of the engine & alternator, extraction,
discharging hot air in to the atmosphere and the temperature rise inside the enclosure, noise level outside enclosure. The acoustic enclosure should be suitable
29.1 3 for cable connection/connection through bus-trunking. Such arrangements on acoustic enclosure should be water proof & dust-proof conforming to IP-65
protection. The enclosure shall be as per CPCB IV + or better norms etc. and as per CPWD specifications.
(I) AMF Panel: Free standing floor mounted IP 42 automatic mains failure control panel including auto by-pass, suitable for KVA as below for silent type DG set
complete with relays, timers, set of CTs for metering & protection and energy analyser to indicate currents, phase and line voltages, frequency, power factor,
KWH, Kilo Volt Ampere Reative Hour (KVARH), KVA (Phase & Total), KW & provision for overload, short circuit, restricted earth fault, under frequency, power
(aluminium) and control (copper ) cabling of suitable size upto 15 meter between AMF panel, LT Panel and DG Set including connection interconnection etc. as
required, all complete and inter locking and communication/ Ethernet /RS485/SNMP port open protocol for BMS integration including suitable software, the panel
shall be of DG Set OEM make etc. as per approved by Engineering in charge and including the following:
Contractor 43 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
1. Suitable numbers and appropriate capacity 4 pole motorised electrically operated draw out with cradle type 3 position ACB/ MCCB with electronic release for
O/C & E/F and shunt trip.
2. Auto/Manual/Test/Off selector switch
3. Protection for under and over voltage phase reversal (2 nos Over voltage relay, 2 Nos. reverse power relay and 2 Nos. under voltage relay).
4. 3 Sets of current transformers 15 P 10 accuracy for protection and 15 VA class-I for metering
5. Energy analyser unit to indicate current, Voltage (LN & L_L), kW, kVA (Phase & Total), Frequency, KWH, PF.
6. LED Indicating lamps for load on mains and load on set
7. Fuse/ MCB for instruments
8. Battery charger, complete with transformer/ rectifier, D.C. voltmeter and ammeter, selector switch for trickle, off and boost and current adjustment.
9.Main supply failure monitor
10.Supply failure timer
11.Restoration timer
12.Control unit with three impulse automatic engine start/stop and failure to start lockout.
13. Impulse counter with locking and reset facility.
14.ON/OFF/Control circuit switch with indicator
15.Audio/Video annunciation for
(i) High water temperature
(ii) Low lubricating oil pressure
(iii) Engine over speed
(iv) Engine fails to start
(v) Full load/maximum load warning
16. Protection for over/under Frequency, Loss of AC sensing, Over Current, Unbalancing load with suitable number of relays and accessories
17. Maintenance notification based on Engine Run Hour & due date.
18. Load Management through PLC to achieve auto opening and closing of incomer breakers, bus coupler switching of essential panel, interlocking providing
signal to AMF Panel for load status and AMF shall give command to DG Set to auto start / auto stop depending upon load status and requirement etc. and
necessary hardware and software required to perform the operation shall be provided by the contractor
including all control wiring
B Sub Head - II : Cabling
M.R. 1 Supplying of one number PVC insulated and PVC sheatehed XLPE power aluminium conducter armoured cable of 11 KV (E) grade of following size etc as reqd. 50 Meter 4864.00 243200.00
22.1 2 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand
cushioning, protective covering and refilling the trench etc as required.
22.1.2 2.1 Above 120 sq. mm and upto 400 sq. mm 50 Meter 694.00 34700.00
22.4 3 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size in the existing masonry open duct as required.
22.4.2 3.1 Above 120 sq. mm and upto 400 sq. mm 25 Meter 146.00 3650.00
23.4 4 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core,
XLPE aluminium conductor cable of 11 KV grade as required:
23.5 5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3
core, XLPE aluminium conductor cable of 11 KV grade as required :
5.4 1 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking 12 Set 8351.00 100212.00
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
5.6 2 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking 12 Set 15004.00 180048.00
arrangement and watering pipe of 2.7 Meter long etc. with charcoal/ coke and salt as required.
M.R. 3 Providing and fixing 50 mm X 6 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation 200 Meter 5750.00 1150000.00
and re-filling etc. as required.
M.R. 4 Providing and fixing 50 mm X 12 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and 200 Meter 2000.00 400000.00
re-filling etc. as required.
Contractor 44 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
M.R. 5 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 100 Meter 2649.00 264900.00
M.R. 6 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 100 Meter 627.00 62700.00
OUTDOOR SUB STATION
2-POLE STRUCTURE:
Supply, erection and commissioning of 2-pole structure for terminating 11 KV O.H. supply from supply company as per specifications and drawing. The 2-pole
structure shall comprise of:-
a) MS tubular swaged pole 11 mtrs high (410SP 24) (as per latest relevant BS standard)or as per Indian std., in cement concrete foundation 1:3:6 (1 cement : 3
coarse sand : 6 graded aggregate 40mm nominal size) including excavation and refilling etc. as required. The rate shall be inclusive of painting with 2 coats of
aluminium paint (on red oxide). The portion of pole under the ground shall be provided with 2 coats of bituminous paint -2 Nos.
b) Steel sections, channels angles, flats, clamps, GI nuts, bolts and required hardware etc of different sizes for cross arms, bracings, supports etc. for pole GODO
etc. including anticlimbing barbed wires (conforming to BS Standard) having 4 points barbs spaced 75 ±12mm apart. All steel structure shall be given 2 coats of
red oxide primer and 2 finishing coats of aluminium paint as required as per drawings and direction of Engineer-in-charge -Lot
c) Supply, installation, testing and commissioning of 11 KV class disc/pin/support insulators complete with clamps and fixing hard disc/pin/support insulators
complete with clamps and fixing hard wares etc. complete as required as per drawings and direction of Engineer-in-charge -Lot
d) Supply, installation, testing and commissioning of 11 KV station class thyrite type lightning arrestors complete with mounting arrangement (on all phases) -1
e) Supply, installation, testing and commissioning of drop out -lock out (DOLO) fuse, gang operating device (Air Break Switch) with pad locking arrangement
(operating rod to be supported properly), complete with operating handle and locking arrangement -1 Set
f) Supply, installation, testing and commissioning of GI stay set complete with 20mm dia 1.8 M long stay rod with 450 x 450 x 7.5 mm anchor plate with thimbles,
stay clamps, 7/4.00 mm dia GI stay wire, turn buckle (20mm x 600mm) strain insulator bow tightner in cement concrete 1:3:6 foundation as excavation and refilling
Earthing of poles with 2 Nos. 20mm dia M.S. rod earthing and connecting the poles with 25 x 6mm GI earth strip. - Lot
Earthing of lightning arrestors with 2 Nos. 32 x 6mm GI strip directly connected with GI pipe Earth station (2 Nos.) as per IS-3043 - Lot.
Two pole structure as described above. Set 1 125000.00 125000.00
Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of cubicle type 11 kV metering panel fabricated out of 14 SWG CRCA
sheet steel, free standing floor readable dust and vermin proof with arrangement for sealing the covers and doors, re-inforcement of suitable size angle iron,
channels, T sections of flats wherever necessary. Cable gland plate shall be provided on bottom of metering panel. Panel shall be treated with allanti-corrosion
process prior to powder coating.
Approval shall be obtained from concerened Electricity Board for the shop drawings before fabrication.
The metering panel shall comprise the following
Trivector Meter of Secure make, accuracy class 0.5
MR 8 3 nos 11 KV cast resin CT's of 50/1 A amps CT ratio, 15VA burden and accuracy class 0.5
1 no. 3 phase potential transformer of approved make by Electricity Board Ratio 11000V/√3/110/√3 VA Burden 100VA Class 0.5
Ratio 11000V/√3/110/√3 VA Burden 100VA Class 0.5
One Set of Phase Indicating Lamps.
2 Sets of HRC fuses with fuse base (H.T. Fuse - 1A & LT fuse 2-6A).
1 Nos. indoor cable end box for suitable for 3C x 95 sq.mm.11 KV(E), aluminium conductor XLPE Al. cable (Incoming & Outgoing cable).
Note: The contractor shall get the Trivector meter, CTs' & PT tested by SEB and the charges for liaison for the same will be paid extra.
The metering panel shall be complete with all interconnections etc. as above including calibration of instruments as per Electricity Board. Set 1 132000.00 132000.00
11kV DISTRIBUTOR BOARD
Supplying, installing, testing and commissioning of Indoor 1no. Incomer and 01no. Outgoing Vacuum Circuit Breaker Panel Comprising of 11kV, 630Amp,
26.3kA/3-sec, Draw-Out type HT Vacuum Circuit breaker panel confirming to IEC 62271-200, IAC AFLR – 26.3kA for 1sec, LSC2B-PM Class, comprising of
630Amp, continuous rated aluminium busbars and droppers, 01no. Line-Earthing Trucks, 01nos. Rack-In-Rack-Out Handles and mandatory spares including
01no. Trip Coils, 01nos. Closing Coils, 01nos. Spring Charging Motors, 02nos. Space Heaters.
The Board shall consist of following panels:
INCOMER PANEL - 01nos., Each comprising of
11kV, 630Amp, 26.3KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker should have 03nos. encapsulated vacuum
bottles of same manufacturer as of circuit breaker. Motorized spring charging mechanism (230VAC) with integral spring charging handle for manual spring charge,
associated Shunt Trip/Close Coils (24VDC):
Current Transformers: 11kV, 300-150/1-1, Core1: Class 5P10, 5VA, Core2: Class 0.5, 5VA
Potential transformers: 11kV/rt3:110V/rt3, 50VA, Class 0.5
Accessories: Local Remote Switch, Breaker Control Switch (T-N-C), space heater with thermostat, DC & AC control circuit through MCB,
Contractor 45 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
Indicating Lamps: for RYB, spring charge, DC Supply healthy, Breaker ON/OFF and TEST/ SERVICE position
Metering Instruments:
Multifunction Meter with RS485 port for MODBUS communication (Acc.Cl.0.5), Digital Ammeter (Acc.Cl.0.5), Digital Voltmeter (Acc.Cl.0.5)
Protection Relays:
01no. Flush-Mounted, Numerical based, 03-OverCurrent+01-EarthFault Feeder Protection Relay, providing OverCurrent (LowSet: 10%-250% / HighSet: 20%-
2500%), Earth-Fault (LowSet: 10%-200%/HighSet: 50%-1250%), ThreePhase Inrush Detection, CktBrkr Control, TripCkt Supervision, ThreePhase & Residual
Current Measurement, Non-Volatile memory for 100-event log, five-fault-record with time-stamp, Local HMI and user-programmable 4DI/6DO for future
deployment of interlocking/changeover scheme.
Relay should be communicable on MODBUS protocol.
Master Trip Relay - DA Aux.
Pluggable Relays for contact multiplication, anti-pumping, spring-charging indication etc. where applicable.
Additional facilities like Arrangement for connecting atleast one run of outgoing cables. Panel Illumination Lamp, Space Heater + Thermostat, Electrical or
Mechanical Anti pumping Protection, Test Terminal Block, Seperate PowerPack with associated BatteryBackup: 24VDC of suitable rating for each VCB, Panel
structure fabrication shall be made of sheet steel with anti-corrosive protection of zinc and aluminum coating. Safety Shutters, Continuous rated closing and
tripping coil. Panel design shall be one-second Fully Internal Arc Type tested for 26.3kA by the works manufacturing the item (principle/licensor/half-panel type-test
reports will not be accepted). Vacuum Bottles of same make as panel manufacturer. Complete Control circuit shall operate on 24VDC, except Spring-Charging-
Motor and SpaceHeater which shall operate on 230VAC.
OUTGOING PANEL - 01 nos. EACH COMPRISING OF
Same description as INCOMER PANEL above, except following changes:
Potential Transformer, Voltmeter, Under/OverVoltage Relay, R-Y-B Phase Indications are not required in Outgoing Panels
PANEL COMPLETE AS ABOVE 1 nos 1250000.00 1250000.00
PANELS WITH REAR ACCESS
Designing, fabricating, transporting, unloading, storing, fixing in position, testing and commissioning the following sheet steel cubicle type panels fabricated from
1.6mm thick CRCA sheet, dust and vermin proof, indoor type TPN Panels with hinged lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3
phase 4 wire 50Hz AC supply with rear access for cable alley and with segregated bus-bar chamber with tinned copper/aluminium bus bar as specified and
including supplying and fixing following switchgears, meters and accessories, inter-connections, bonding to earth, powder coated painting and marking as
specified. Switch boards complete as per schematic diagram:
Type of construction: Form 3
IP classification: 42
All MCCBs in Main LT Panel shall have minimum 50 kA breaking capacity
The LT PANEL shall be electrically inter-locked as shown in Schematic diagram and as detailed in the Specifications
Colour: Siemens Gray Powder Coated, as per approved sample.
ALL PANELS MUST BE EQUIPPED WITH GAS FLOODING SYSTEM
(NOTE: Interlocking of the incoming breakers and coupler to be coordinated with PLC in DG Control Panel with suitable control wiring and auxillary contacts left
Panel must have suitable entry for bus duct and rising main wherever required
INCOMER (Transformer)
1 nos 1000A FP electrically operated draw-out type ACB with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type
indication, with Reverse Power Relay and three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current,
Frequency, Power, Energy, Power factor, RS 485 port for connection to BMS system and set of suitably sized CTs including protection with 2A HRC fuses and
suitable number of auxilary contacts for electrical interlocking as described.
INCOMERS (DG SET)
MR 10 1 nos 800A FP electrically operated draw-out type ACB with microprocessor-based relay for O/L, S/C and E/F protection with time delay facility and fault type
indication, with Reverse Power Relay and three phase indicating lamps, 1no 96mm x 96mm multi parameter digital meter with LCD display for Voltage, Current,
Frequency, Power, Energy, Power factor, RS 485 port for connection to BMS system and set of suitably sized CTs including protection with 2A HRC fuses and
suitable number of auxilary contacts for electrical interlocking as described.
2 nos 630 A TPN MCCB with thermal-magnetic release setting of 80%-100%, rotary operating handle and ON indication with 1no 96mm X 96mm digital 3-phase
current Ammeter with suitably rated CTs and protected with set of 2A SP HRC fuses.
1 nos 400 A TPN MCCB with thermal-magnetic release setting of 80%-100%, rotary operating handle and ON indication with 1no 96mm X 96mm digital 3-phase
current Ammeter with suitably rated CTs and protected with set of 2A SP HRC fuses.
2 nos 250 A TPN MCCB with thermal-magnetic release setting of 80%-100%, rotary operating handle and ON indication with 1no 96mm X 96mm digital 3-phase
current Ammeter with suitably rated CTs and protected with set of 2A SP HRC fuses.
Contractor 46 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
4 nos 100A TPN MCCB with thermal-magnetic release setting of 80%-100%, rotary operating handle and ON indication with 1no 96mm X 96mm digital 3-phase
current Ammeter with suitably rated CTs and protected with set of 2A SP HRC fuses.
10 nos 63A TPN MCB with rotary operating handle and ON indication with 1no 96mm X 96mm digital 3-phase current Ammeter with suitably rated CTs and
protected with set of 2A SP HRC fuses.
1no 800A FP electrically operated draw-out type ACB with ON/ OFF indication and suitable number of auxilary contacts for electrical interlocking as described
Equally sized three phase and neutral aluminium conductors busbar suitably sized to carry 1250A current and suitably insulated with colour coded Heat Shrink
Panel complete as above 1 nos 1875000.00 1875000.00
Supplying, erecting, testing and commissioning outdoor duty floor mounted weather proof IP54 feeder pillar fabricated as detailed in description given in E.1 above
but with double door (lockable outer door), sloping roof, water run-off gutter on three sides as per approved drawing, entire unit mounted on 50mm x 50mm x 5mm
angle iron with minimum 300mm long "legs":
1nos 40A TPN MCB.
1 no 96mm x 96mm multi parameter digital meter with LCD display for voltage & current with suitably rated CTs and MCB protection.
1 set of three phase indicating lamps with suitable protection.
MR 11 Busbar: Equally sized three phase and neutral copper conductors busbar suitably sized to carry 100A current and suitably insulated with colour coded Heat Shrink
1 nos. 25A TP MCB
3 nos. 40A DP ELCB.
18nos.6/10/16A SP MCB
2 nos. 16A water proof outlet.
Feeder Pillar complete as above 1 nos 90000.00 90000.00
Safety equipments
MR 1 Supplying & Erection of following safety equipments at suitable places as required.
MR a CO2 (Carbon Dioxide) type fire extinguisher Confirming to IS:15683 with cylinder fully charged of 4.5 Kg. capacity (ISI marked.) 2 Each 6400.00 12800.00
MR b ABC Powder type Fire Extinguisher (Stored Pressure type) Capacity 06 Kg duly ISI marked conforming to IS: 15683:2006, with IS 14609 (ISI marked.) 2 Each 3200.00 6400.00
MR c A set of 4 Nos. Fire Buckets with 50 mm x 50 mm x 6 mm thick angle iron suitable stand etc. as required (Confirming to IS-25461974). 2 Each 4500.00 9000.00
MR d Industrial First Aid small kit having Metal Box wall mounted with acrylic door as approved by St. JOHN AMBULANCE BRIGADE or Indian Red Cross Society as 2 Each 3500.00 7000.00
per IS code 2217 '1963
MR e Electric shock treatment chart of size 24" X 18" as per BIS 1986 duly framed in glass frame work i/c mounting arrangement. 2 Each 4500.00 9000.00
Supplying & Fixing of Fire retardant / Extinguishing Elect. Insulated mat of 3.0 mm thick + 10% according to IS: 15652, 2006 meeting requirements of IS: 3043, IS: 10 Sq Meter 1600.00 16000.00
5216 (Part 1,2& 3), IS: 8437 and IEC 479 Pub-1, Tested for breakdown strength, tensile/ elongation, ageing, properties, Insulations resistance,effects of acid,
alkaline, diesel & transformer oil, leakage current test, having min. width of 1000 mm + 20 mm. All allied material such as pu-resin, chemi bound (Hardener), spl.
PVC adhesive, liquid primer and sealing material and similar tape of matching colour and matching design tapes should be used to maintain any aesthetic look of
the insulation over the joints and corner as per in servicerecommendation of Annexure "A" Clause C of IS: 15652 and suitable for Class-C upto 33 KV etc
complete as required
Supplying & Fixing of Fire retardant / Extinguishing Elect. Insulated mat of 2.0 mm thick + 10% according to IS: 15652, 2006 meeting requirements of IS: 3043, IS: 10 Sq Meter 1200.00 12000.00
5216 (Part 1,2& 3), IS: 8437 and IEC 479 Pub-1, Tested for breakdown strength, tensile/ elongation, ageing, properties, Insulations resistance, effects of acid,
alkaline, diesel & transformer oil, leakage current test, having min. width of 1000 mm + 20 mm. All allied material such as pu-resin, chemi bound (Hardener), spl.
PVC adhesive, liquid primer and sealing material and similar tape of matching colour and matching design tapes should be used to maintain any aesthetic look of
the insulation over the joints and corner as per in service recommendation of Annexure "A" Clause C of IS: 15652 and suitable for Class-A upto 3.3 KV etc
complete as required
10.1 Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle 100 Each 598.00 59800.00
iron, 60 cm long and fixing the same in ground as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II
15.16 3 complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning
and protective covering etc., complete as required.
Contractor 47 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SUBSTATION
DSR E&M DSR NON-DSR
S No Description QTY UNIT Rate
All Figure are in Rs. All Figure are in Rs.
15.16.5 a 200 mm dia (OD-200 mm & ID-175 mm nominal) 100 Meter 733.00 73300.00
Based on Supplying, installation by suspension on ceiling, testing and commissioning of following capacity Sandwich Type Rising Mains/Bus Duct for use on 3 phase 4 wire
31.13 415 volts, 50Hz A.C. supply with metal clad enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly
powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints,
elbow joints & expansion joints and bends, fire barrier at each floor, provision of tapping at every metre, adopter box and copper flexible for joints, continuous
earthing with 2 Nos aluminium strip of suitable size (one on each side) including, G.I. clamping brackets, suspenders, angle iron bracket, steel fasteners,
connecting to earthing
system etc. as required
Contractor 48 Digitally signed by NBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing and Commisioning of SINGLE LEVER
CONCEALED BASIN MIXER (WALL MOUNTED) WITH SPOUT
1 MR (COMPOSITE ONE PIECE BODY) LPM should be 2.5 with suitable EACH 48 16080.00 771840.00
aerators as per GRIHA norms. Manufacturer should have valid
GRIHA certification
Supply, Installation, Testing and Commisioning of TABLE TOP
BASIN, SIZE: 630x460x130mm
Supply, Installation, Testing and Commisioning of suitable
3 MR compatible WASTE COUPLING 32MM- FULL THREAD- WITH EACH 48 2398.00 115104.00
CERAMIC CAP-*130MM HEIGHT *65MM CERAMIC CAP
Supply, Installation, Testing and Commisioning of BOTTLE TRAP
(WITH INTERNAL PARTITION) 32mm SIZE WITH 300mm &
190mm LONG WALL CONNECTION PIPES & WALL FLANGE
Supply, Installation, Testing and Commisoning of RIMLESS, BLIND
INSTALLATION WALL HUNG WC WITH UF SOFT CLOSE SLIM
SEAT COVER, HINGES AND ACCESSORIES SET, SIZE:
Supply, Installation, Testing and Commissioning of PNEUMATIC
Supply, Installation, Testing and Commisoning of ANGULAR STOP
COCK WITH WALL FLANGE
Supply, Installation, Testing and Commissioning of CONCEALED
8 MR STOP COCK WITH ADJUSTABLE WITH WALL FLANGE 15mm EACH 48 4965.00 238320.00
Supply, Installation, Testing and Commisiong of HAND SHOWER
(HEALTH FAUCET) WITH 8mm DIA 1.2 METER LONG FLEXIBLE
TUBE AND WALL HOOK ALD-CHR-573 or equivalent. LPM should
be 3.8 with suitable aerators as per GRIHA norms. Manufacturer
should have valid GRIHA certification
Supply, Installation, Testing and Commisiong of PNEUMATIC
SINGLE PIECE SLIM CONCEALED CISTERN BODY WITH
10 MR INSTALLATION KIT & “S-TYPE” DRAIN PIPE CONNECTION SET EACH 48 8044.00 386112.00
FOR WALL HUNG WC (WITHOUT FLUSH CONTROL PLATE). This
should be as per the GRIHA norms of 2L/4L LPF
Contractor 49 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Providing and fixing P.V.C. waste pipe for sink or wash basin
including P.V.C. waste fittings complete.
17.28.2 Flexible pipe
Providing and fixing mirror of superior glass (of approved quality)
12 17.31 complete with 6mm thick hard board ground fixed to wooden cleats EACH 48 1607.95 77181.60
with C.P. brass screws and washers complete.
Providing and fixing C.P. brass angle valve for basin mixer and gyser
13 points of approved quality conforming to IS : 8931
18.53.1 15 mm nominal bore EACH 192 574.30 110265.60
Cutting chases in brick masonry walls for following diameter sand
cast iron/centrifugally cast (spun) iron pipes and making good the
same with cement concrete 1:3:6 (1 cement: 3 coarse sand: 6
14 graded stone aggregate 12.5 mm nominal size) including necessary
plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand)
Cutting holes upto 30x30cm in walls including making good the
18.76.1 With common burnt clay F.P.S. (non modular) bricks EACH 48 416.80 20006.40
Making chases upto 7.5 X 7.5 cm in walls including making good and
finishing with matching surface after housing G.I. pipe etc.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, including fixing the pipe with
clamps at 1.00 m spacing. This includes jointing of pipes & fittings
with one step CPVC solvent cement and testing of joints complete as
per direction of Engineer in Charge.
Internal work - Exposed on wall
18.7.2 20mm nominal outer dia pipes METRE 350 335.00 117250.00
18.7.3 25mm nominal outer dia pipes METRE 200 401.55 80310.00
18.7.4 32mm nominal outer dia pipes METRE 180 518.75 93375.00
18.7.5 40mm nominal outer dia pipes METRE 100 702.95 70295.00
18.7.6 50mm nominal outer dia pipes METRE 80 934.15 74732.00
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all
CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps
at 1.00 m spacing.
This includes jointing of pipes & fittings with one step CPVC solvent
cement and the cost of cutting chases and making good the same
including testing of joints complete as per direction of Engineer in
Concealed work including cutting chases and making good the walls
18.8.1 15mm nominal outer dia pipes METRE 700 497.80 348460.00
18.8.2 20mm nominal outer dia pipes METRE 400 537.60 215040.00
18.8.3 25mm nominal outer dia pipes METRE 200 627.25 125450.00
18.8.4 32mm nominal outer dia pipes METRE 100 739.30 73930.00
Contractor 50 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Providing, fixing, jointing and testing in position of ISI marked UV
stabilized UPVC pipes for soil, waste, and vent, Type-B as per IS
: 13592 suitable for rubber ring joints, including all neccessary
specials and fittings (confirming to IS:14735) i.e. bends, tees,
junctions (with or without doors), reducers, WC connectors,
couplers, expansion joints / bellows, cowels, clamps, rubber rings,
clean outs etc. fixing at wall/ ceiling/ floor level supported by clamp &
hangers etc. in concealed / inside duct / under floor & basement
ceiling / external work etc. including chase cutting as required,
excavation and back filling in all kind of soils, suspended from floor
under false ceiling or embedding the pipes laid under floors / building
19 in 75 mm. alround 1:2:4 cement concrete (1 cement : 2 coarse sand
MR : 4 graded stone aggregate 20 mm nominal size) including cost of
shuttering for proper completion of the work, breaking and making
good the walls and floors etc. after pipes have been duly laid and
tested. The rubber ring shall confirm to IS:5382.
The Pipes will be supported with threaded G I rods & U clamps with
nuts, washers etc on 50x50x5 mm slotted angle. The cost will
include all support arrangements. The work includes commissioning
of all pipes lines as per drawings and specifications and as directed
by engg-in-charge at site.
a 110 mm dia (Wall Thickness - 3.2 to 3.8 mm) METRE 800 536.00 428800.00
b 75 mm dia (Wall Thickness - 3.2 to 3.8 mm) METRE 150 416.00 62400.00
Providing, fixing, jointing and testing in position ISI marked (IS:4985)
UPVC pipes of min 6 Kg/ Sqcm rating with fitting for waste pipe
from fixtures to floor trap including reduces, enlarger, socket,
couplers, bends, tees etc including fixing at wall/ ceiling level
supported by clamp & hangers etc. cutting holes in wall/ floors/ slabs
and making good the same with cement concrete 1:2:4 complete as
Providing & fixing UPVC Floor trap of self cleansing design with
21 MR stainless steel grating complete in all respects.
Plain Floor Trap (4" Ht) with 50 / 75 outlet and with height raiser EACH 125 536.00 67000.00
Extra for providing & fixing 125 mm dia C.P. grating in place of C.I.
grating over floor traps.
Providing & fixing of SS Floor Cleanout, round or square with rubber
23 MR seal and flat round cover with screws and other required fitting EACH 125 1001.00 125125.00
complete as required.
MR Supply, Installation, Testing and Commisiong of HIGH FLOW EACH 22 18938.00
24 SINGLE LEVER CONCEALED DIVERTOR FOR BATH & SHOWER 416636.00
MR Supply, Installation, Testing and Commisiong of SPOUT FOR EACH 22 9377.00
BUILT IN BATH/SHOWER MIXER
MR Supply, Installation, Testing and Commisiong of OVERHEAD EACH 22 24100.00
SHOWER 350x350MM ROUND EDGE SQUARE HEAD SINGLE
FLOW (BODY & FACE PLATE STAINLESS STEEL WITH CHROME
PLATED) WITH RUBIT CLEANING SYSTEM
Contractor 51 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing and Commissioning of 15 litre geyser
Supply, Installation, Testing and Commisiong of SOAP DISH
Supply, Installation, Testing and Commisiong of TUMBLER
Supply, Installation, Testing and Commisiong of TOWEL RACK
600MM LONG WITH LOWER HANGER
31 MR Supply, Installation, Testing and Commisiong of ROBE HOOK EACH 22 2045.00 44990.00
Supply, Installation, Testing and Commisiong of TOWEL HOLDER
Providing and fixing white vitreous china battery based infrared
sensor operated urinal of approx. size 610 x 390 x 370 mm having
pre & post flushing with water (250 ml & 500 ml consumption),
having water inlet from back side, including fixing to wall with suitable
brackets all as per manufacturers specification and direction of
Engineer-in-charge.
Supply Installation, Testing and Commisioing of Handicap Toilet
34 MR special fixtures to the complete satisfaction of the engineer in charge
(a) SITC of Grab Bar vertical swing white Each 5 9867.00 49335.00
(b) SITC of Grab Bar Left/Right 90 angle Each 5 7271.00 36355.00
(c ) SITC of Grab Bar 842mm long white Each 5 4664.00 23320.00
Providing and fixing C.P. brass bib cock of approved quality to
conforming to IS 8931.
a 18.49.1 15 mm nominal bore Each 48 506.80 24326.40
Providing and fixing C.P. brass long body bib cock of approved
36 18.51 quality conforming to IS standards and weighing not less than 690
a 18.51.1 15 mm nominal bore Each 2 798.95 1597.90
Providing and fixing C.P. brass stop cock (concealed) of standard
design and of approved make conforming to IS : 8931.
a 18.52.1 15 mm nominal bore Each 58 670.45 38886.10
38 18.9.6 50mm nominal outer dia pipes M 200 794.25 158850.00
Providing and fixing gun metal gate valve with C.I. wheel of
approved quality (screwed end).
a 18.17.1A 20 mm nominal bore Each 80 539.95 43196.00
b 18.17.1 25 mm nominal bore Each 40 622.40 24896.00
c 18.17.2 32 mm nominal bore Each 16 689.60 11033.60
d 18.17.3 40 mm nominal bore Each 4 826.10 3304.40
e 18.17.4 50 mm nominal bore Each 4 1026.65 4106.60
Providing and fixing ball valve (brass) of approved quality, High or
low pressure, with plastic floats complete :
a 18.18.3 25 mm nominal bore Each 6 464.05 2784.30
Providing and fixing unplasticised PVC connection pipe with brass
18.21.1 30 cm length
a 18.21.1.1 15 mm nominal bore Each 100 85.00 8500.00
Contractor 52 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Providing and placing on terrace (at all floor levels) polyethylene
water storage tank IS: 12701 marked with cover and suitable locking
arrangement and making necessary holes for inlet, outlet and
overflow pipes but without fittings and the base support for tank
Excavating trenches of required width for pipes, cables, etc including
excavation for sockets, and dressing of sides, ramming of bottoms,
depth upto 1.5 m including getting out the excavated soil, and then
2.10 returning the soil as required, in layers not exceeding 20 cm in depth
including consolidating each deposited layer by ramming, watering,
etc. and disposing of surplus excavated soil as directed, within a lead
2.10.1 All kinds of soil
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm
Providing and fixing square-mouth S.W. gully trap class SP-1
complete with C.I. grating brick masonry chamber with water tight
19.4 C.I. cover with frame of 300 X 300 mm size (inside) the weight of
cover to be not less than 4.50 kg and frame to be not less than 2.70
kg as per standard design :
19.4.1 100 X 100 mm size P type
a 19.4.1.2 With Sewer bricks conforming to IS : 4885 Each 10 2685.20 26852.00
Constructing brick masonry manhole in cement mortar 1:4 (1 cement
: 4 coarse sand) with R.C.C. top slab with 1:2:4 mix (1 cement : 2
coarse sand : 4 graded stone aggregate 20 mm nominal size),
foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded
stone aggregate 40 mm nominal size) inside plastering 12 mm thick
19.7 with cement mortar 1:3 (1 cement : 3 coarse sand) finished with
floating coat of neat cement and making channels in cement
45 concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate
20 mm nominal size) finished with a floating coat of neat cement
complete as per standard design :
19.7.1 Inside size 90 X 80 cm and 45 cm deep including C.I. cover with
frame (light duty) 455 X 610 mm internal diamensions total weight of
cover and frame to be not less than 38 kg (weight of cover 23 kg and
weight of frame 15 kg):
a 19.7.1.2 With Sewer bricks conforming to IS : 4885 Each 15 12711.80 190677.00
19.7.3 Inside size 120 X 90 cm and 90 cm deep including C.I. cover with
frame (medium duty) 560 mm internal diameter, total weight of cover
and frame to be not less than 208 kg (weight of cover 108 kg and
weight of frame 100 kg)
a 19.7.3.2 With Sewer bricks conforming to IS : 4885 Each 1 32719.50 32719.50
47 19.8 Extra for depth of manholes
19.8.1 Size 90x80cm
19.8.1.2 With Sewer bricks conforming to IS : 4885 Meter 15 8654.25 129813.75
19.8.2 Size 120x90cm
19.8.2.2 With Sewer bricks conforming to IS : 4885 Meter 1 10381.45 10381.45
Contractor 53 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Constructing brick masonry road gully chamber 50 X 45 X 60 cm with
bricks in cement mortar 1:4 (1 cement : 4 coarse sand) including 500
X 450 mm precast R.C.C. horizontal grating with frame complete as
per standard design :
19.27.1 With common burnt clay F.P.S. (non modular) bricks of class
designation 7.5
Supply, Installation, testing and commisioning of Domestic Water
Pumps(to lift water from underground domestic water tank to terrace
tank of building)Location - Near underground water tank with Level
Controller with sufficient nos. of low / high level alarms, contacts with
electrodes and control wiring for the automatic operation of all water
supply pumps to achieve the functional requirement shall be
provided. Control wiring between these pumps and water tanks shall
be provided. Raw water pumps must start at low level of water in
49 underground domestic water tank & stop at high water level in that
tank. Dry running protection shall be provided for all the pumps.All
water supply to operate automaticaly through level controller.
(a) Capacity 1 LPS each minimum
RPM 2800 / 2 HP
SUBMERSIBLE SUMP PUMPS FOR PLANT ROOM DRAINAGE
(Location : Basement of the Building)
Supplying, Installation, Testing & Commissioning of dewatering
single stage submersible non clog type (Capable of solid handling of
20 mm diameter) self priming of suitable HP pump with casing in
SS., Impeller in SS & shaft in SS with auto level controls (to stop at
Low Level and to Start at High Level in the sump) having discharge
of 250 LPM at 12 Mtr head complete with all accessories suitable for
operation on 230 Volt 3 phase 50hz AC supply as required for plant
room. The pump shall be inclusive of strainer, sluice/gate valve, non
return valve, float switch,...Etc
Flow Rate =250 LPM
HP - as per maufacturer recommendations.
Quantity (Set=1 Working + 1 Standby)
Control panel, configuration with all standard feature like , contactor
,relays, MCB Tp, Amp-meter, volt meter, single phase / Three phase
preventer , over load, dry run protection, Start, Stop, Indicators, Auto,
manual, Sequential, timer etc. all of reputed make like: L&T/
Installation testing & commissioning of pump
Cable 2x 1.5 squire mm (Supply and lying /Terminating).
Ø 50mm GI pipe (Make Pipe JINDAL/SURYA) with Ø50 mm 1No
Ball valve, 1 No NRV Ø 50mm. (Make: SANT/ZALOTO).
Contractor 54 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Providing and Fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal
ring conforming to IS: 5382, leaving 10mm gap for thermal
expansion, (i) Single socketed pipes.
Providing and fixing on wall face unplasticised PVC moulded fittings/
accessories for unplasticized Rigid PVC rain water pipes conforming
52 12.42 to IS : 13592 Type A, including jointing with seal ring conforming to
IS: 5382, leaving 10mm gap for thermal expansion.
12.42.1 Coupler
12.42.6 Shoe (Plain)
Providing and fixing unplasticised PVC pipe clips of approved design
to unplasticized PVC rain water pipes by means of 50x50x50 mm
hard wood plugs, screwed with M.S. screws of required length,
including cutting brick work and fixing in cement mortar 1:4 (1
cement : 4 coarse sand) and making good the wall etc. complete
Providing and fixing to the inlet mouth of rain water pipe cast iron
54 12.44 grating 15 cm diameter and weighing not less than 440 grams Each 20 54.70 1094.00
Providing, laying and jointing glazed stoneware pipes class SP-1 with
55 19.1 stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1
fine sand) including testing of joints etc. complete :
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) all-round
S.W. pipes including bed concrete as per standard design :
a 19.2.2 150 mm diameter S.W. pipe meter 160 1179.85 188776.00
b 19.2.3 200 mm diameter S.W. pipe meter 160 1375.45 220072.00
Contractor 55 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - SANITARY & PLUMBING WORKS
DSR 2023/ DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
MR All Figure are in Rs. All Figure are in Rs.
Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse
sand : 10 graded stone aggregate 40 mm nominal size) up to
haunches of S.W. pipes including bed concrete as per standard
a 19.3.2 150 mm diameter S.W. pipe meter 160 743.10 118896.00
b 19.3.3 200 mm diameter S.W. pipe meter 160 873.50 139760.00
Providing and laying non-pressure NP2 class (light duty) R.C.C.
pipes with collars jointed with stiff mixture of cement mortar in the
proportion of 1:2 (1 cement : 2 fine sand) including testing of joints
etc. complete :
Supply, Installation, Testing and Commisioning of Sensor based
basin mixer wall mounted. LPM should be 2.5 with suitable aerators
as per GRIHA norms. Manufacturer should have valid GRIHA
Supply, Installation, testing and Commisioning of Touch free infrered
Supply, Installation, testing and Commisioning of Automatic soap
Supply, Installation, Testing and Commisioning of Toilet Paper
Holder with flap
Supply, Installation, Testing and Commisioning of Wall Mounted
Paper Towel Dispenser
Supply, Installation, Testing and Commissioning of Electromagnetic
Flow Meter/ Water Meter having the following specs suitable for
pipes upto 50 mm dia pipes:
Transmitter: Die Cast
Power Supply: 90 – 265 VAC
Outputs: 4-20 mA , Pulse, RS485
64 MR Process Pressure: 10 Bar each 4 25300.00 101200.00
Sensor Terminal Housing: C.S
Fabricated IP65
Display: Remote Display With 5
Flange: ASA #150 C.S
Electrode: SS316L
Grounding Electrode: SS316L
Flow Tube: SS304
Coil Housing: C.S
Protection Class: IP-66
Contractor 56 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: HVAC
S No Description Unit Quantity Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
VRF OUTDOOR UNIT: Supply, Installation, Testing & Commissioning of Modular type Variable
Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoor units suitable for
cooling/heating having 100% hermetically sealed inverter type twin Rotary/Scroll
Compressor(s),minimum two compressors (with individual separate PCB) for above 14HP
modules, microprocessor based Controller, top discharge type condensing unit(s), with R-410-A
Refrigerant or equivalent, vibration Isolators with suitable foundation etc. complete as required. To
have better efficiency condenser fan shall be capable to operate at different speed with respect to
load. The unit shall deliver the rated capacity and in confirmation as per IS 18728:2024 and
CPWD Specifications and work even at 50°C ambient temperature without tripping. The system
shall be able to deliver 100% of the rated capacity upto 39 Degree Celcius.The unit shall be
1 31.3 suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply and BMS compatible. The unit
shall be filled with first charge of the refrigerant and ready for use as required. The condenser
should be coated with a hydrophilic film to prevent water accumulation on the surface of the heat
exchanger, enhance water dispersion, and reduce the risk of degradation, thereby improving
overall performance and durability. The Indian Seasonal Energy Efficiency Ratio (ISEER) of the
unit shall be as per Energy Conservation and Sustainable Building Code (ECSBC) 2024 as below
and complete as per CPWD specification, connections, inter connections etc. as required. (For
capacity <40 kWr ISEER 7.4, Capacity > 40 and <70 ISEER 7.5, Capacity > 70 ISEER 7.6 for
Super ECSBC Building)
For Cooling or Heating or Both
VRF INDOOR UNITS: Supply, Installation, Testing and Commissioning of following minimum
capacity High wall type Indoor unit equipped with and comfort washable synthetic media pre-filter,
fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with
DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan,
necessary accessories etc., suitable for operation on 230 V ± 10%, 50 Hz, single phase AC
2 31.8 supply, complete as required. The Indoor units must shut down upon receiving a singal from the
BMS System/Fire Singnals. The system shall be capable to adjust air flow as per room
requirement automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27
Degree C DB and 19 Degree C WB temperature. (Make will be same as of Outdoor)
Contractor 57 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: HVAC
S No Description Unit Quantity Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing and Commissioning of following minimum capacity Single way wall/corner
VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter,
fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper
coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation,
3 31.6 Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC
supply,complete, as required. The Indoor units must shut down upon receiving a singal from the BMS
System/Fire Signals. The system shall be capable to adjust air flow as per room requirement
automatically. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19
Degree C WB temperature. (Make will be same as of Outdoor)
INDOOR UNIT Supply, Installation, Testing and Commissioning of following minimum capacity 4 way
Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section
with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX Copper coil,
electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration Isolation,
4 31.4 Corded remote control etc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply,
complete, as required. The Indoor units must shut down upon receiving a singal from the BMS
System/Fire Signals. The system shall be capable to adjust air flow as per room requirement in auto
mode. The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree
C WB temperature. (Make will be same as of Outdoor)
Supply, Installation, Testing and Commissioning of Y/T/Multi Joints. Joints shall be of same Original
Equipment Manufacturer (OEM) make as of ODUs and IDUs
b 31.13.2 Outdoor Multi Joint Nos 12 8,098.00 97,176.00
REFRIGERANT PIPING:
Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following
nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings,
with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with
XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves
sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per
specifications etc. as required:
Contractor 58 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: HVAC
S No Description Unit Quantity Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
a 31.14.1 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 500 256.00 128,000.00
b 31.14.2 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 1675 346.00 579,550.00
c 31.14.3 12.7 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 500 487.00 243,500.00
d 31.14.4 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm Metre 1675 615.00 1,030,125.00
e 31.14.5 19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 400 739.00 295,600.00
f 31.14.6 22.2 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 400 904.00 361,600.00
g 31.14.7 25.4 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 300 1,068.00 320,400.00
h 31.14.8 28.58 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm Metre 300 1,157.00 347,100.00
i 31.14.9 31.8 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Metre 100 1,222.00 122,200.00
j 31.14.10 34.9 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Metre 100 1,286.00 128,600.00
k 31.14.11 38.1 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Metre 50 1,322.00 66,100.00
l 31.14.12 41.27 mm dia (OD) (Hard drawn) with tube thickness 1.62 mm Metre 50 1,368.00 68,400.00
a MR 300x75mm outdoor cable tray with cover (hot dip galvanized) Metre 700.00 1,439.00 1,007,300.00
DRAIN PIPING For VRV HVAC
8 Providing and fixing of uPVC/cPVC/PVC drain pipe
CONTROL CABLING
Supplying, receiving, storing, laying, effecting proper connections, testing and commissioning of the
9 following sizes of 1.1 KV grade PVC insulated copper conductor unarmoured stranded control cable
complete as required.
a MR 2C x 1.5 mm² Cu (Communication cable from ODU to IDU for VRF units) Metre 2610 274.00 715,140.00
Supply, Installation, Testing & Commissioning of Silent type circular /rectangular inline fans for exhaust air
complete with sheet metal casing, 25mm thick acoustic insulation, direct driven centrifugal fan, motor with
proper protection and inspection door. Fan shall be suitable for operation on 220+6 % volts, 50 Hz,1
phase AC power supply. Flanges to be provided on both sides to facilitate duct connections. Fan shall be
10 installed as shown in the drawings and will be of following characteristics:
MR All single phase inline fans shall be provided with factory fitted speed regulators. All Fans Should be
complete with Plug Top & necessary power cable.
Fans shall have low noise level in rage of 35-40dBA @3m and shall be suitable for indoor installations.
a 200 CFM S P of 13-14 for Toilet Nos. 24 6500.00 156000.00
b 500 CFM S P of 13-14 for Kitchen Nos. 2 9500.00 19000.00
Contractor 59 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: VENTILATION
DSR E&M DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
1 Exhaust Fans - Axial Flow Type :
( Fire rated : 250 deg for 2 Hrs. )
Providing, fixing, testing and commissioning of AMCA Certified (For Air and Sound
Performance) tube / vane axial flow fan of different capacity as mentioned below in standard
M.S. construction. Entire fan model & AMCA Seal shall appear in technical submittal of fan. All
the fans are synthetic enamelled painted/hot dip galvanized with minimum 220 GSM Zinc
Coating and complete with bird screen at inlet. The electric motor coupler shall be squirrel cage
induction motor (IE-3 type) confirming to IS - 325-IP - 55 with class `H' insulation. Motor shall be
MR of high temperature resistance "Class H Smoke Spill" 250° C for 2 hrs. Fan shall be TUV / CE
Certified for high temperature. Fan shall be EN 12101-3 Certified high temperature. Motor
should be VFD rated. Fan efficiency should not be less than 70 %. Noise level should not more
than 80 dB @ 3 mtr distance when measured in hemispherical reverberant room conditions,
for normal (non-fire) conditions, and not more than 85 dB @ 3mtr distance for fire conditions.
Fans should be as per specification and drawings.
(i) Normal Mode
(ii) Emergency Mode
2 Lift well Pressurization Axial fan
Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with
Hot dipped Galvanised Steel Casing with spun flanges, adjustable pitch die cast aluminium
impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the
MR job requirement and shall be marked on the fan assembly.The complete fan
assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be
sourced from one manufacturer. Fan mut be AMCA certifeid for Air & sound both
3 Lift Lobby Pressurization Axial fan
Supply, installation, testing and commissioning of Direct drive Tube Axial fans complete with
Hot dipped Galvanised Steel Casing with spun flanges, adjustable pitch die cast aluminium
impeller (Hub and Aerofoil blades) and IE3 motors. Casing position shall be as per the
MR job requirement and shall be marked on the fan assembly.The complete fan
assembly with its casing, impeller and motor ( not only motor or one of the item ) shall be
sourced from one manufacturer. Fan mut be AMCA certifeid for Air & sound both.
Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal
rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers,
4 30.12.2 vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required
complete in all respect in confirmation with IS : 655 and approved drawings and specifications
of following sheet thickness complete as required.
Contractor 60 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: VENTILATION
DSR E&M DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
Supply, installation, testing and commissioning of Motorized (ON-OFF Type) duct mounted GI
volume control damper with enthalpy sensor and necessary control wire for integration within
5 30.14 AHU room complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc in
confirmation to SMACNA/IS and as per specifications complete etc. as required.
Supplying, Fixing, installation, testing and commissioning of powder coated extruded SQM 20 9,623.00 192,460.00
6 30.15 aluminium Supply Air Grills with aluminium volume control dampers in confirmation to
SMACNA/IS and as per specifications complete etc. as required.
Supplying & fixing of powder coated extruded aluminium Return Air Grills with louvers but SQM 20 6,285.00 125,700.00
7 30.16 without volume control dampers complete in confirmation to SMACNA/IS and as per
specifications complete etc. as required.
Electrical Panels
Supplying ,testing and commissioning of combined sheet steel cubicle type panels fabricated
from 14 guage thick CRCA sheet, dust and vermin proof, indoor type Panels with hinged
lockable doors fabricated from 2mm thick CRCA sheet, suitable for 415V, 3 phase 4 wire 50Hz
AC supply with rear / bottom access for cable alley and with segregated bus-bar chamber and
including supplying and fixing following switchgears, meters and accessories, inter-connections,
bonding to earth, bottom base channel of MS. Entire panel shall have a common earth busbar
at rear with 2 nos earth stud cable alleys, cable gland plates powder coated painting of
approved shade after antirust treatment and marking as specified. Switch boards complete as
per schematic diagram: panel with fan starter for Fesh/ exhaust/ lift &lobby pressurization. It
should accept and offer command to & from fire alarm system. Programmable to run and
control fan operation in normal, early fire, ventilation and fire mode based on fire alarm signal
or Manual operation. Fan should be operable in Manual / Auto fan mode. Panel should be
equipped with emergency stop mushroom type push button for emergency stop condition.
Panel should equipped with over voltage, over current, phase protection, short circuit protection
with motor starter based on DOL / Star - Delta. Bus bar should be hot sleeved with suitable
8 MR Cable entries provided from top. Bimetal overload relay for all the starters shall have built-in
single phasing prevention feature. Electrical interlocking wiring shall be provided as per system
requirement. System fault/trip reset arrangement shall be provided as required.
Incomming MCCB of 250 Amp Rating with necessary metering and indications etc complete as
approved by Engineer in charge.
Bus bar of suitable ratings
Outgoings for Lift well and staircase pressuresation:-6 nos
For Normal and Emergency mode Axial flow fans:- 6 nos
Details for each fans
Contractor 61 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: VENTILATION
DSR E&M DSR NON-DSR
S NO DESCRIPTION UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
63 A TPN MCB for motor-01 set.Digital type ammeter to read (0 - 32) Amp, digital type
Voltmeter (0-500)V, A set of CT's, RYB LED type phase indication lights -- 01 set. Fully
automatic DOL Starter with built-in single hasing preventor, over load relay and (0-30) seconds
adjustable timer suitable for -01 set. Auto-Manual type selector switch/timer to facilitate auto
start of fan after restoration of power. Control wiring & safety circuit as required with Start-Stop
PB's and LED type 'ON' & 'OFF' indication lights.
Complete as above set 2 250,000.00 500,000.00
Contractor 62 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: LIGHTING FIXTURES
DSR E&M DSR NON-DSR
S No Description QTY Unit RATE
All Figure are in Rs. All Figure are in Rs.
LED Down lighter (COB Type) (System lumen efficacy ≥120 lm/Watt ) Supplying, Installation, Testing & Commissioning of
LED Recessed/surface Down lighter (Round / square/ Rectangular) COB Type of following body material and construction
as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit
protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below
5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with, 70% of initial Lumen
maintained till life ends , CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour
Matching)<3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant
1 8.1 BIS standard. Manufactures Word Mark/ Name Engraved/Embossing/ Screen printing on housing. OEM must have its
own in house NABL lab setup for all testing facilities for LED fixtures. "complete in all respect i/c external
connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test
report and all testing required for LED fixtures as per BIS shall be submitted Shape size and CCT shall be as
approved by Engineer-inCharge as per requirement. (Thermal management: heat sink of aluminium housing such that
LED junction temperature shall not rise above 90°C). Powder coated die cast/ Extruded aluminium Body including trim
with Aluminium Reflector
LED Batten light (System lumen efficacy >135 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface
mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the
requirement with Driver efficiency >85% ,Operating voltage AC 140 270 Volt, frequency 50/60 hz, Operating temp range
-5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20,
CRI >80, Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000
Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As
per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the
2 8.11 specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/
Screen printing on housing complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System
lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS
shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder
coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Contractor 63 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: LIGHTING FIXTURES
DSR E&M DSR NON-DSR
S No Description QTY Unit RATE
All Figure are in Rs. All Figure are in Rs.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy >135 lm/Watt).
Supplying, Installation, Testing & Commissioning of Street light LED fixture, powder coated pressure die cast
aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-
270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per
IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under
voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle as per IESNA type I/II/III as
per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver &
electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per
3 8.14 LM80 extrapolation IES TM-21-11 report, CCT 3000°K /4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard
Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall
be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System
lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS
shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal
management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
Supply, Installation, Testing and Commissioning of Integral, SMD 4x1 Backlit LED Panel, IP 20, 30W LED recessed
mounted fixture with system efficacy of minimum 100lm/W and system lumen output of minimum 3000lm, operating in
ambient temperature of 0⁰C to 45⁰C at 50Hz frequency. Luminaire shall have CRCA housing coated in white (RAL9016)
with translucent HET diffuser for uniform illumination and wider light distribution. LEDs used in the product shall
comply with IEC 62471. LM 80-08 compliant LEDs should be provided. The LED shall comply with L70 life of 50000
burning hours tested at maximum current. The LEDs used should be with CCT of 4000 K and CRI of Minimum
4 MR 80. LED Driver shall be Isolated type, Constant Current topology driver with proper heat sink for heat dissipation 276 nos 3500.00 966000.00
suitable to operate in input voltage range of 140V to 300V (nominal rated voltage – 240V) with 4KV internal surge
protection, Power factor of minimum 0.95 and total harmonic distortion (THD) of less than or equal to 10% should
be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India.
LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance
to Indian Standards of IS10322 Part 5 / Sect 5:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) :
Supply, Installation, Testing and Commissioning of 20W, recessed/suspended by 1.5m suspension wire, 4 feet linear,
IP40 from front, SMD LED luminaire with system efficacy of 120 lumen/watt and system lumen output of 2400 lumen,
operating in an ambient temperature of 0⁰C to 45⁰C. Operating at 50Hz frequency, luminaire shall have extruded
aluminium housing in white with high efficiency translucence diffuser and must have provision for end to end seamless
connectivity. EMC package of wattage of 0.2-0.5 W LEDs used in the product shall comply with IEC 62471 for Photo-
biological safety. LM 80-08 compliant LEDs should be provided. The LED shall comply with L70 life of 50000 burning
hours tested at maximum current. The LEDs used should be with CCT of 4000/5700 K and CRI of Minimum 80, with
MacAdam CCT binning ≤3 mounted on 1.6mm FR4 / MCPCB with 35 micron cu layer. LED Driver shall be Isolated type,
5 MR Constant Current topology driver with proper heat sink for heat dissipation suitable to operate in input voltage range of 49 nos 4000.00 196000.00
140V to 300V (nominal rated voltage – 240V) with 4KV internal surge protection, Power factor of minimum 0.95, driver
efficacy of minimum 85% and total harmonic distortion (THD) of less than or equal to 10% should be integral to the
luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80
reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards
Dimension: 1204 X 50 X 75mm, weight: 1.6Kg with all connectors to give continous cascading effect wherever required as
per the directions of engineer in charge
Contractor 64 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: LIGHTING FIXTURES
DSR E&M DSR NON-DSR
S No Description QTY Unit RATE
All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing and Commissioning of 1200mm dia Pendent Mounted Ring LED. Fixture to be made of
extrusion Aluminum housing in white finish with HET plastic diffuser. LED Used shall be SMD type with Minimum system
Lumens 4800 @60W & efficacy 80lm/W,Life of fixture : 50000 burning Hrs. @ L70 Lumen maintenance, CCT of
4000/5700K (SDCM<=3), CRI Ra >=80, PF >0.95, operating Voltage Range of 150-270 V AC. Minimum Internal Surge
Protection 2.0KV. LED driver should have CISPR 15 / EN 55015 compliance to limit for radio disturbance characteristics.
Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports
need to be submitted from a NABL/UL accredited lab to verify above parameters. Both the fixture and Driver should have
separate BIS approval.
Supply, Installation, Testing and Commissioning of 30W LED Decorative Post Top type luminaire with System efficacy of
120 lm/W (3600 lumens), suitable for external poles of dia. 60mm to 75mm. Fixture dimension: 480X470mm, height:
550mm (including PDC base). Light fixture should have Dark Sky certification to avoid light pollution and power wastage.
Luminaire shall be made up of pure polyster power coated RAL7021 pressure die cast Aluminium housing with PC lens
and tempered glass with street light optics. All external hardwaremust be of SS304 grade. LM 80-08 compliant LEDs of
EMC/ceramic package should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological
safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 and IK07 protection.
The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM
80 test report for LED should be submitted for 10000 hrs of testing) with ambient operating temperature -10° to +45° C.
7 MR The LEDs used should be with CCT of 4000/5700 K, CRI of Minimum 70 and SDCM <5. LEDs must be driven at max 10 Nos 14523.00 145230.00
70% of the rated current. MCPCB with Aluminium core and copper thickeness of 35 micron to be used for LED mounting.
LED Driver shall be silicone potted, Integrated type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency
> 85% & 5 KV internal surge protection, 10KV external surge protection, Power factor greater than 0.95 and total
harmonic distortion (THD) of less than 10% should be integral to the luminaire. OEM should provide Dark Sky Certificate
mentioning the name of the item along with unique ID issued by "Dark Sky International". Manufacturer shall have inhouse
lab approved by NABL or ministry of science of govt of India. LM79 and LM80 reports need to be submitted from a
NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect 5:1967;
Supply, Installation, Testing and Commissioning of 11W LED Decorative Bollard with System lumen output of 300
lumens. Luminaire shall be made up of dark grey, pure polyester power coated extruded Aluminium housing specially
design to provide beautiful light pattern on ground surface. Light fixture should have Dark Sky certification to avoid light
pollution and power wastage. Fixture dimension: 150X150mm, length: 1004mm, weight: 4.3Kg. LM 80-08 compliant LEDs
of EMC/ceramic package should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological
safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP65 protection. The LED
shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test
report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 3000 K, CRI of
8 MR Minimum 70 and SDCM <5. LEDs must be driven at max 70% of the rated current. MCPCB with Aluminium core and 2 Nos 14000.00 28000.00
copper thickness of 35 microns to be used for LED mounting. IP65 rated LED Driver shall be silicone potted, Integrated
type, Isolated, Constant Current with range 140-280V AC. Driver Efficiency > 80% & 2.5KV internal surge protection,
Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire.
OEM should provide Dark Sky Certificate mentioning the name of the item along with unique ID issued by "Dark Sky
International". Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM79 and
LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Compliance to Indian
2012 should be there.
Contractor 65 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: LIGHTING FIXTURES
DSR E&M DSR NON-DSR
S No Description QTY Unit RATE
All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing and Commissioning of 18W recessed, deep inset COB LED Downlight luminaire having 1620
lumens with dimensions of 92mm x 92mm and height of 56mm. The cut out dia (Φ) should not be more than 85mm x
85mm. Luminaire shall be made up of pure polyster powder coated pressure die cast Aluminium housing with inbuilt heat
sink to provide better thermal management to enhance LED life. The luminaire should be equiped with the secondary
optics of high efficiency polycarbonate lens to provide UGR < 19. The luminaire should have beam angle of 70°.LM 80-08
compliant ceramic / aluminium base LEDs should be provided. LEDs used in the product shall comply with EN 62471 for
Photo-biological safety and certificate for the same from manufacturer shall be provided. The luminaire should be IP20
rated. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current
9 MR (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 266 Nos ₹ 2,200.00 585200.00
4000/5700 K and CRI of Minimum 80. LED Driver shall be IP20 rated, non-integrated type, Isolated, Constant Current
operated driver with range 100-265V AC. Driver Efficiency > 85% & 2.5 KV internal surge protection, Power factor greater
than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall
have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted
from a NABL/UL accredited lab to verify above parameters. Compliance to Indian Standards of IS10322 Part 5 / Sect
Supply, Installation, Testing and Commissioning of LED based Spike light, housing made up of pressure die cast
aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer
and optics made of surface mount reflector with toughened. The fixture should have a minimum system efficacy of
80lumen/Watt and a minimum system lumen output of 640 lumens and maximum system wattage of 8 Watts.The fixture
shall have a CRI of minimum 80 and beam angle: 50-55deg. The fixture shall be designed for a system life of 50,000
hours @70% lumen maintenance. Ingress Protection of IP67 (lamp and gear Compartment) and Mechanical Impact
Resistance Rating of IK >=07, CCT: 2700K. The fixture driver should have an operating voltage range of 100-270 V, surge
protection of >=3KV, PF >0.9, THD<10% & Driver efficacy >80% @full load and rated voltage. Ambient temp range: 0deg
to 45deg C. The Drivers should be a potted driver not a printed circuit board without casing, mounted inside the luminaire.
The fixture should comply with the parameters as per IS10322. Manufacturer shall have inhouse lab approved by NABL .
LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters.
SITC of decorative wall bracket having canopy arm chrome lamp cup with E27 lamp holder and LED bulb. Dimension:
L180XW120XH300mm ±2mm.Wipro cat No.: LM91/LT/Regent
SITC of Aluminium LED (Wall Highlighter) - 12W Modern Black Finish Wall Sconce Light for bedside indirect lighting
complete in all respect
Contractor 66 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: FIRE DETECTION AND ALARM SYSTEM WITH PUBLIC ADDRESS AND 2-WAY COMMUNICATION
DSR (E&M) DSR NON-DSR
S No Description Qty Unit Rate
2025/MR All Figure are in Rs. All Figure are in Rs.
Supplying, installation, testing and commissioning of micro processor based
intelligent addressable main fire alarm panel, central processing unit with the
following loop modules and capable of supporting not less than 240 devices
(including detectors) and minimum 120 detectors per loop and loop length up to 2 km,
network communication card, minimum 320 character graphics/ LCD display with keypad
and minimum 4000 events history log in the non volatile memory (EPROM), power
1 28.2 supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free
batteries with automatic charger. The panel shall have facility to connect printer to printout log
and facility to have seamless integration with analog/digital voice evacuation system
(which is part of the schedule of work under SH: PA System) and shall be complete with
all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/
Modbus over IP complete as per specifications
Supplying, installation, testing & commissioning of repeater panel with 320 character/ Touch
3 28.2.3 screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 7.00 Each 113734.00 796138.00
Supplying, installation, testing & commissioning of intelligent analog addressable
4 28.2.4 photothermal detector with in-built isolator complete with mounting base complete as required. 330.00 Each 3004.00 991320.00
Supplying, installation, testing & commissioning of response indicator on surface/recessed MS
5 28.2.5 Box having two LED, metallic cover complete with all connections etc as required. 165.00 Each 306.00 50490.00
Supplying, installation, testing & commissioning of fault isolator complete with base as
Supplying, installation, testing & commissioning of intelligent addressable thermal detector with
7 28.2.9 rate of rise cum fixed temperature thermistor having in-built isolator complete with base as 80.00 Each 2866.00 229280.00
Supplying, installation, testing & commissioning of addressable fire control module complete
Supplying, installation, testing & commissioning of addressable phone control module
complete as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as
Supplying, installation, testing and commissioning of addressable duct detector including
suitable photo detector complete with base as required
Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB,
13 28.3.1 MP3 player (including 6 zone button paging station) with seamless integration facility with main 1.00 Each 132115.00 132115.00
fire alarm panel for voice evacuation complete as required.
Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as
Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers
complete as required.
Supplying, installation, testing and commissioning of digital audio amplifier 250 watt, 25V rms
operating at 240 Volt AC Supply complete as required
Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with
microphone assembly complete as required.
Contractor 67 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: FIRE DETECTION AND ALARM SYSTEM WITH PUBLIC ADDRESS AND 2-WAY COMMUNICATION
DSR (E&M) DSR NON-DSR
S No Description Qty Unit Rate
2025/MR All Figure are in Rs. All Figure are in Rs.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed
19 28.5.2 copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete 4400.00 Each 386.00 1698400.00
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess
20 1.2 including painting in case of surface conduit, or cutting the wall and making good the same in
case of recessed conduit as required.
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the
21 existing surface / recessed steel conduit of following pairs, cores and size including
connections and interconnections etc. as required.
(a) 28.5.3.1 Speaker cable Single pair, 2-core, 1.5 sqmm 1680.00 Mtr. 61.00 102480.00
Supplying & Fixing of battery operated illiminated "EXIT" signage, with 2hrs power
Battery backup complete as required.
Contractor 68 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable
for automatic operation and consisting of following, complete in all respects, as required:
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze
impeller with stainless steel shaft, mechanical seal conforming to IS 1520.
(b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable
1 27.1. for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure,
horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.
(c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as
(d) Suitable cement concrete foundation duly plastered with anti vibration pads.
Supplying, installation, testing and commissioning of diesel engine driven main fire pump
suitable for automatic operation and consisting of following, complete in all respects, as
(Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and
bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520. Suitable
HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard
complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank,
exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass
wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and
protection as per standard specification, stop solenoid for auto stop in the event of fault with
audio indications, painted with post office red colour etc. as required. MS fabricated, common
base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement
concrete foundation duly plastered and with anti vibration pads.
(a) Supplying, installation, testing and commissioning of electric driven pressurisation pump
conforming to IS 12469: 2019 suitable for automatic operation and consisting of following,
complete in all respects, as required : (Jockey Pump) (b)Horizontal type, multistage,
centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical
seal as required. (c)Suitable HP squirell cage induction motor TEFC type suitable for
3 27.3 operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure,
horizontal foot mounted type with Class 'F' insulation, conforming to IS-12615: 2018. 194
DELHI SCHEDULE OF RATES (E&M)-2025 (d)M.S. fabricated Common base plate,
coupling, coupling guard, foundation bolts etc. as required. (e) Suitable cement concrete
foundation duly plastered and with anti vibration pads.
Contractor 69 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
CONTROL PANELS: Fabrication, supplying, Installation testing & commissioning of Electrical
control panel of cubicle construction, floor mounted type, fabricated out of 2mm thick CRCA
sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated
of approved shade after 7 tank treatment process, cable alley, inter-connection with suitable
size copper conductor cable/solid copper strip, having switchgears and accessories,
mountings and internal wiring, earth terminals, numbering etc. complete in all respect,
suitable for main fire pump, pressurisation pump & diesel pump set complete as per CPWD
specifications with following in coming and Outgoings, suitable for operation on 415V, 3
phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :
Incomings 400A, 50kA 4 Pole MCCB, Ics=100% Icu rating Digital Voltmeter 0-500V with
selector switch Ammeter (0-400 A) with selector swtich & CTs etc. LED type RYB phase
indicating lamps, ON, OFF, trip indicating lamps Set of Copper Bus Bar 500A Outgoings
(Note : All outgoing feeders for pumps should have digital Ammeter with selector switches,
and LED type ON, OFF, trip indicating lamps) Main Fire Pump 200 A, 50kA TPN MCCB,
Ics=100% Icu, with fully automatic Star/Delta starter suitable for 75 hp pump with overload
protection, current sensing type single phase preventor complete with all acceessories and
internal wiring required for automatic operation, selector switch for local/remote,
auto/manual/OFF operation. Jockey Pump 100 A, 50kA TPN MCCB, Ics=100% Icu, with
suitable HP fully automatic Star/Delta starter with overload protection, current sensing type
single phase preventor complete with all acceessories and internal wiring required for
27.5.2 automatic operation, selector switch for local/remote, auto/manual/OFF operation. Diesel 1 Each 300803.00 300803.00
Engine Control Control for diesel engine comprising - Automatic/Manual selctor switch & 3
attempt starting device, timers and relays as required, push buttons, start/stop in manual
mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp and Engine on
indication Battery charger suitbale for 12V/24 V DC with boost and trickle selector switch, 0-
30 V DC volt meter, and 0-20 A DC Ammeter
All standard relays and accessories for automatic operation of diesel engine
Designing, Supply, Installation, Testing and commissioning of System Controller to control
operation of main electric fire pump, diesel pump, Pressurization pump, Terrace pump in
sequence as per specification consisting of relays, timers.
Sensors, annunciation window for fault indication, complete as per specifications.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS
1239/Class -II of IS: 3589 including Welding, fittings like elbows, tees, flanges, tapers, nuts
6 27.7 bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame
and painting with two or more coats of synthetic enamel paint of required shade complete as
Contractor 70 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Providing laying, testing & commissioning of 'C' class heavy duty MS Pipe conforming to IS
1239/Class -II of IS: 3589 i/c fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.
7 27.6 in ground including welding, excavation & providing cement concrete blocks as supports,
anticorrosive treatment with coaltar/asphalt tape as per IS 10221, refilling the trench etc. of
following sizes complete as required.
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with
8 27.11 bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets
conforming to IS 13095 of following sizes as required :
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with
9 27.12 non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers,
gaskets and conforming to IS 780 of following sizes as required :
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with
orifice of required size to be fitted between flange & landing valve of external and internal
hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes
11 27.14 confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
Providing, installation, testing and commissioning of stainless steel Y-strainer fabricated out of
12 27.15 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel
Contractor 71 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supplying and fixing single headed internal hydrant valve with instantaneous
Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming
to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
13.1 27.9.1 Single headed Gunmetal 7 NOS 8208.00 57456.00
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia
instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked,
conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as
14.1 27.10.1 Single headed Gunmetal 4 NOS 8208.00 32832.00
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red,
conforming to IS 884 complete with the following as required. (a) 20 mm nominal internal dia
water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 (b) 20 mm nominal
internal dia gun metal globe valve & nozzle. (c) Drum and brackets for fixing the equipmets on
wall. (d)Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female
16 27.16 couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal
17 27.18 diameter size nozzle conforming to IS 903 suitable for instantaneous connection to
interconnect hose pipe coupling as required :
18 MR Providing and fixing standard firemans axe with heavy rubber handle. 11 NOS 1056.00 11616.00
Supplying and fixing of fire brigade connection of cast iron body with gun metal male
19 27.19 instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe
connection conforming to IS 904 as required :
Providing and fixing weather proof cabinet of size not less than 0.6 x 0.6 x 0.45 mtr made out
of M.S. sheet not less than 1.5 mm thick having central opening and 4 mm thick glazed glass
doors (Two nos.) suitably marked on the outside 'with the letters "FIRE HOSE" including
20 MR necessary locking arrangement and painting in red colour suitable to accomodate, external 4 NOS 11095.00 44380.00
yard hydrant valve, 2 nos 15 mtr long Hose pipe, branch pipe, nozzle and fire man's axe. It
shall be mounted on boundary wall complete as required.
Contractor 72 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Providing and fixing 4 mm thick glass door of size 2.1 m x 0.9 m with anodized aluminium
frame of size 0.10 x 0.05 M with centre opening for fire hose cabinet. Suitably marked on the
outside with the letters "FIRE HOSE" including locking arrangement. All aluminium work to be
in Red P.O. colour.
Providing and fixing ISI Marked of approved make Fire Extinguishers complete with all
accessories as per manufacturer's specifications.
22 MR a) CO2 gas nozzle type - 9 Litre capacity (IS:15683). 14 NOS 11600.00 162400.00
b) Mechanical Foam gas cartridge type. 9 Kg capacity (IS:15683). 14 NOS 5260.00 73640.00
c) ABC dry powder stored pressure type 6 kg capacity (IS:15683). 14 NOS 4476.00 62664.00
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating
68 degree centigrade with required accessories :
23.1 27.21.1 Pendant sprinkler 639 Each 599.00 382761.00
23.2 27.21.2 Upright Sprinkler 411 Each 599.00 246189.00
23.3 27.21.2 Horizontal side wall sprinkler 44 Each 699.00 30756.00
Providing, fixing, testing & commissioning of installation control valve of cast iron body,
brass/bronze working parts comprising of water motor alarm, bronze seat clapper, clapper
arm and hydraulically driven mechanical gong bell to sound continuous alarm when the wet
24 27.24 riser/sprinkler system activates, pressure gauges, emergency releases, strainer, pressure
switch, cock valve complete with drain valve and bypass, test control box, ball valves, MS
pipe of required size, flanges, orifice plate, gasket etc of follwing sizes as required :
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in
height with air release valve on top and flanged connection to riser, drain arrangement with
25 27.20 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith 1 set 19402.00 19402.00
synthetic enamel paint of approved shade as required.
Providing and fixing of pressure switch in M.S. pipe line including connection etc as required
Providing and fixing of flow switch in following sizes in M.S. pipe line including connection etc
Supplying, installation, testing & commissioning of sprinkler flexible pipe (UL Listed) of
stainless steel complete with 15 NPT on reducer thread with maximum working pressure of
175 PSI test pressure ofc875 PSI (Burst) with branch line (Inlet) 25mm NPT male thread to
sprinkler head (Outlet) 15mm NPT female thread with reducer, nipple, 2 side brackets, center
bracket, stockbar of following sizes complete as required.
Contractor 73 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES:FIRE PIPING,HYDRANTS,SPRINKIERS AND ACCESSORIES
S No 2025 DESCRIPTION QTY UNIT RATE DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
SAFETY SIGNAGE:Providing and fixing of photo luminiscent/visual markers signage made
out of photo luminiscent, produced luminization with suitable colours combination (Glow in
dark) with high intensity luminious properties covered with U/V statilized coating having
following features complete as required.
(a) Thickness of aluminium/ACP sheet 2.00 mm ±10%
(b) Service temperature - 40 C to 120 C
(c) Suitable for indoor surface, glow visibility for more than 8 hrs in total darkness.
One sided signage written in English and also in regional Language,if required, for the below
dimension Fire Safety Signages.
Signage printed with the above stated specification for
(i) "NO SMOKING" with board size 4" x 12" at suitable point,
(ii) Floor indentification signage with board size 4"x12" at suitable point,
(iii) Exit signage board size 4"x12" at suitable point,
(iv) Colour signages for " EVACUATION MAP OF EACH FLOOR" with board size of 18"x24" 16128 SQ INCH 22.50 362880.00
at suitable point,
(v) Lift Alert with board size 8'x12' at suitable point,
(vi) Signages of " FIRE ORDER" with the board size of 24"x36" at main exit/entry (Gr. Floor)
TOTAL AMOUNT 9242821.00 825170.00
TOTAL AMOUNT 9242821.00 825170.00
Contractor 74 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUQNTITIES: IT PASSIVE
S No Item Description Unit Qty Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supplying, Installation, Testing and commissioning of following CAT6A Patch Cord
39.13 should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-
1 D etc. complete as required.
39.13.1 Copper Patch Cords of length 1m (3ft) Set 289 173.00 49,997.00
39.13.2 Copper Patch Cords of length 3m (10ft) Set 289 405.00 117,045.00
Supply, Installation, Testing and Commissioning of loaded Patch Panel 24 Port Cat 6A
U/UTP ,The Cat-6Atransmission performance is in compliance and Exceeds
ANSI/TIA/EIA-568.2-D Standard. Supports 1000-Base-T. 90 Degree (Top Entry) or 180
Degree Punch Down Design for Convenient Network Terminations, Individual
replaceable jack module panel design as applicable.UL Listed, Complaint to RoHS
Directive 2011/65/EU and (EU) 2015/863 and ASTM B 117 Certified. OEM should have
ISO 9001:2015, ISO 14001:2015and ISO 45001:2018 or latest.All networking passive
material (Fiber Cable, Copper Cables, Networking Racks and their connectivity
components) should be from one OEM make only for Data as per given Specification
etc. all complete
Supply Installation Testing & Commissioning of 1 uPVC Cable Manager as per given
specification etc.
Supply, Installation, Testing & Commissioning of Mounting Hardware pack of 10pcs as
per given specification etc. all complete
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor Standing
Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side panels, L-
Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking completely knocked-
down condition (CKD) Shape, fitted with 4 number cooling fans, minimum 8nos two line
cable entry/exit provision at top and bottom with rubber protection, Front door 5mm
Toughened Glass with MS frame or MS perforated with lock, Rear MS vented or
perforated door, Powder coated Color- RAL- 7035 or black, complied with UL & RoHS, 2
x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware
mounting screws packet of 20 x 1 number, etc. complete as required.
Supplying, Installation, Testing and commissioning of CAT6A Copper Information Outlet
(IO) with face plate of color as per site requirement, should have ETL/UL verification
6 39.15 program certificate for compliance with ANSI/TIA-568.2-D. All copper Cable and Nos 289 302.00 87,278.00
components should be from same OEM to maintain compatibility and interoperability
etc. complete as required.
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid
copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal
(solid) Cable suitable for high speed data networking application supporting upto
10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with
color coded insulation for easy indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew
should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have
been tested and verified by UL/ ETL etc. complete as required.
Contractor 75 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUQNTITIES: IT PASSIVE
S No Item Description Unit Qty Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supplying, Installation, Testing and commissioning of RJ45 Connector for CAT 6/6A
Cables. RJ45 modular plug supports 4 twisted pairs, 8 positions, 8 connectors. Housing:
PC, UL94V-2, transparent color, Use for 24- 26 AWG stranded wires etc. complete as
Supplying and drawing following core Multi mode Fiber Optic Cable having corrugated
steel armoring, leser optimize 50/125 μm with HDPE jacket, LSZH (Low smoke Zero
Halogen), Tight-buffered or loose tube, maximum attenuation: < 3.5 dB/km at 850 nm, <
1.5 dB/km at 1300 nm, bandwidth > 2000 MHz-km at 850 nm, > 500 MHz-km at 1300
nm compliance and certifications: ISO/IEC 11801 Ed. 2.2, ANSI/TIA-568-C.3, ITU-T
G.651.1 RoHS compliant. Multi Mode Fiber shall be Central-loose tube filled with
Thixotropic jelly, duly following Standards: ISO 11801, IEC 60793-1/60794-1-2, ITU-T-
REC G.652D and Telecordia GR-20-core, High quality Electro Chromium Coated
9 Corrugated Steel tape (ECCS ) and HDPE- Sheath, Operating ambient Temperature
should be – 5 0C to +50 0C and Storage Temperature should be – 5 0C to +50 0C,
Maximum Attenuation ± 3.5 dB/km at Operational Wavelength 850 nm and ± 1.5 dB /
km at Operational Wavelength 1300 nm . type of fiber should be 50/125 / G.652D &
Refractive Index should be 1.483/1.478, The value for Mode-filed, Cladding Diameter 50
± 2.5 μm and 125 ± 1μm correspondingly i/c splicing & marking etc complete as
39.20.1 6 Core Multi Mode Optical Fiber Cable meter 200 87.00 17,400.00
Contractor 76 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: INTEREGRATED IT ACTIVE
DSR E&M DSR NON-DSR
S No Item Description Unit QTY Rate
All Figure are in Rs. All Figure are in Rs.
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 3 Network
Switch having features and specifications etc. as mentioned here under: At least 20 X RJ-45
Gigabit Ethernet Ports and additional 4 combo 10/100/1000 base-t/SFP Ports
with additional 4 SFP+ ports non-blocking architecture by having Switching capacity of min.
128Gbps and packet forwarding rate of 95Mpps or higher, 16K MAC table. Console Port, USB port,
Internal AC Power supply with operating temperature of 0 to +50 0C.
Stacking port with stacking support of minimum 8 units per stack. 48K Mac address, 9K or more
Jumbo frame, ERPS with enabling ring to converge in less than 50 ms from node or link failure,
Static routing, Static, 6to4, ISATAP and GRE, IPv6 Neighbor Discovery (ND), BGP, ISIS, MPLS,
VRRP v2, OSPFv2/v3, PBR, Route Redistribution, RIPv1/v2/ng, IP Helper all L3 Protocols should
1 39.4 support from day 1 for both IPv6 and IPv4, 802.1x, Port security, Radius C TACACS+ Nos 1 193,791.00 193,791.00
authentication C accounting, DAD, DAI, DoS attack prevention, SSH, Guest VLAN, IP Access List,
MAC Access List. Multicast: VLAN, PIM-SM, PIMDM, PIM- SDM, PIM-SMv6, DVMRP v3 and
MSDP, IGMP C MLD Snooping, Flow mirroring, IGMP C MLD Snooping Ǫuerier, Per-VLAN IGMP
C MLD Snooping. SNMP, Dual configurations, Multiple images, RMON, LLDP/LLDP-MED, sFlow,
DHCP/BOOTP Client, IPv4/IPv6, Syslog server, Debug command, 802.3ah Ethernet Link OAM,
802.1ag Connectivity Fault, Y.1731 OAM, 802.1Ǫbb Priority- based Flow Control (PFC), Dying
Gasp, Cable Diagnostics , 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45
access ports. Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted
Telecom Portal of Department of Telecommunication, Government of India etc. complete as
Supplying, installation, Testing and commissioning of following capacity 24 port Layer 2 indoor
Network Switch having features and specifications etc. as mentioned here under: At least 24 X RJ-
45 Gigabit Ethernet Ports and additional 2 X 10G Base -T with 4 X SFP Ports with non-blocking
architecture by having Switching capacity of min. 168Gbps and packet forwarding rate of 125Mpps
or higher, 16K MAC table. Console Port, USB port, Stacking support of min. 8 units per stack.
Internal dual AC Power supply, STP, RSTP, MSTP, BPDU Filter, BPDU Restriction, Min. 9K Jumbo
Frame, LBD, IGMP Snooping V1/V2/V3, MLD Snopping V1/V2. IGMP /MLD Groups 1K or more,
IPv4/IPv6 Loopback Interface, 16 L3 IP Interface, Ipv6 ND, VRRPv3, UDP Helper, ECMP. VLAN:
802.1Ǫ, Port based, Ǫ-in-Ǫ, Multicast VLAN, Protocol VLAN, VLAN Trunking, DHCP Snopping,
Server, server Screening. RADIUS , TACACS+ Authentication, ǪoS: 802.1P, 8 queues per port,
2 ǪoS : WRR, Strict+WRR, WRED, 802.1p. ACL: MAC based, IPv4C IPv6, TCP/UDP Port number,
time based ACL, TFTP Client, SNMP V1, v2c, v3, SNMP traps, RMON, DHCP server, relay, client,
LLDP, LLDP-MED, OAM, Dying Gasp, 802.3ah, sflow, RIP, OSPF v2/v3, policy based route, SSL,
SSH. 6 kV surge protection on all Gigabit Ethernet ports and on all GE RJ-45 access ports.
Certifications: UL, CE, FCC, RoHS, MTCTE, OEM/Product must be on Trusted Telecom Portal of
Department of Telecommunication, Government of India etc. complete as required.
24 port PoE Layer 2 Network Switch with PoE Support of 370W or higher with each copper port
supporting 802.3at PoE+ min.
39.3.2 24 port Layer 2 Non-PoE Network Switch Nos 11 86,163.00 947,793.00
Contractor 77 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: INTEREGRATED IT ACTIVE
DSR E&M DSR NON-DSR
S No Item Description Unit QTY Rate
All Figure are in Rs. All Figure are in Rs.
Supplying, Installation, Testing and commissioning of small form-Pluggable (SFP) for Network
Switches. Must be hot Pluggable, RoHS Complaint, etc. complete as required.
39.6.3 10 G SFP + Single Mode/Multi Mode Nos 2 14,972.00 29,944.00
Supplying, Installation, Testing and commissioning of indoor Wireless Access Point for High
density use having features and specifications etc. as mentioned here under- WiFi6 802.11ax
574Mbps (2.4GHz) + 2402Mbps (5GHz), WIFI 6 Certified, 1 x RJ45 console port, MG 2.5G LAN
POE Port, factory reset, WPA/WPA2/WPA3™ personal/ Enterprise, WEP 64/128-bit, SSID
broadcast disable, MAC address access control, Internal RADIUS server, SNMP, Customizable
Captive Portal, Auto Channel, Works as Access Point, WDS, WDS with AP, Wireless Client, Web
(HTTP), Secure Socket Layer (SSL), Traffic control, Support ATF/Fast Roaming/Band Steering,
4 39.8 Supports enhanced security – WPA-PSK/WPA2 PSK/WPA3-PSK and RADIUS client, and Cipher Each 18 35,559.00 640,062.00
negotiation, and MAC/ IP ACL for networks, Certifications: MTCTE, CE, FCC. Works as
Standalone, Compatible with S/W & H/W Controller with addtional features like - Real-Time
Monitoring and Alerts, Rich Advanced Features, Centralized Device Management, Role-Based
Administration, Real-Time Monitoring, VLAN and Access Control, Auto RF Management and
Bandwidth Optimization, Multi-SSID and Captive Portal Authentication.OEM/Product must be on
Trusted Telecom Portal of Department of Telecommunication, Government of India etc. complete
Supplying, Installation, Testing and commissioning of indoor Wireless Controller having features
and specifications etc. as mentioned here under- The network controller shall be a dedicated
hardware appliance designed for centralized management of wireless access points, It must
support the management of up to 500 networking devices, The system should be on-premise,
ensuring data privacy and complete control over network configurations. It must include an intuitive
user interface for real-time monitoring, device discovery, firmware upgrades, scheduling, and mass
configuration deployment. Features such as role-based administration, multi-site management. AP
to controller communication shall be use of industry standards-based (IEEE or IETF) CAPWAP or
any tunneling protocols as per guidelines of DoT.The controller should support Layer 2 and Layer 3
device discovery, VLAN configuration, MAC ACL groups, IGMP snooping, and bandwidth
optimization. Automatic radio frequency (RF) management and access policy enforcement are
5 39.10 required for reliable wireless performance. The solution must offer a comprehensive dashboard Each 1 113,228.00 113,228.00
with network topology, floor plan views, client and device lists, and alert notifications. For
authentication, it should support a range of methods including local database, external RADIUS,
LDAP, and passcode or MAC-based access. It should provide detailed traffic analytics, logs, and
customizable reporting for network visibility and planning. Firmware and configuration backup and
restoration functions must be available, with USB based log storage supported. Physical
specifications should include a compact form factor with a minimum of one 2.5G Ethernet port and
USB 3.0 port, and it must be MTCTE,CE, FCC, and RoHS certified. The controller should operate
reliably within a 0°C to 40°C temperature range and 10–90% non-condensing humidity. Product
must be on Trusted Telecom Portal of Department of Telecommunication, Government of India
etc. complete as required.
Contractor 78 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: EPABX (TELEPHONE & INTERCOM SYSTEM)
DSR DSR NON-DSR
S NO DESCRIPTION Unit QTY RATE
2025/MR All Figure are in Rs. All Figure are in Rs.
Supplying, installation, testing and Commissioning of IP based voice
communication system with 04 Port Voicemail, 04 Port FXS, 04 Port
FXO, 1 PRI Trunk lines (30 Channels) Circuit with CLIP Facility, min
100 IP users License with provision for further additions, 100 analog
users, 01 Number IP based Operator Console, 100 Party
1 38.1 Conference, Speed Dial, Music on Hold, Internal/ External ring Each 1 1,578,920.00 1,578,920.00
difference, Call Barring, Call Pickup, Redundant server in active -
Active mode and as per technical specification including supporting
accessories etc complete as required. The system should have valid
TEC GR approval from DoT.
Supplying, Installation, Testing & Commissioning of Type 1 IP Phone
having 2 VoIP account, 120 x40 DOT matrix screen with backlight,
Full HD duplex speaker phone, IPV6, Gigabit Etherent, PoE etc.
complete as required.
Supplying and drawing 20 Pair 0.5 mm dia FRLS PVC insulated
annealed copper conductor, unarmored telephone cable in the
existing surface/ recessed steel/ PVC Conduit etc. complete as
Supplying, Installation, Testing & Commissioning of Analog phones
having standard feautres like 16 digit LCD display, 2 way speaker,
caller ID and number storage facility etc. complete as required.
Contractor 79 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUNATITIES:INTERGRATED ACCESS CONTROL SYSTEM
S No Item Description Qty Unit Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Access Control System with Face recognition Supplying, Installation, Testing and Commissioning of
Access Control System comprising of Face and fingerprint Recognition, Smart Card, QR Code, NFC &
PIN Code based Reader, following sizes of 5” IPS TFT Touch Screens, 1GB RAM, 8 GB ROM, Live
Face Detection with anti-spoofing against 2D photograph, mobile selfie & video, Fake Fingerprint and
face Detection Technology, 30,000 Face storage (1:N) /, 3,000 fingerprint (1:N), QR code 30,000,
30,000 card storage (1:N), 2 lakh transaction storage, 20,000 image logs, onboard dual camera (colour
1 41.1 & IR) Primary camera min 2MP, Support authentication & verification from up to 1 meters,
Communication protocols WiFi, TCP/IP, Wiegand Out, Wiegand IN, USB, MQTT protocol, Blacklist
Employee Management, User wise authentication modes; Built in Lock Control, Mask Detection & Alert
(configurable), 40 to 30,000 lux illumination, IP65 for Ingress Protection, Certification: CE, FCC, BIS,
ROHS, etc. Metal Enclosure with battery backup, suitable for mounting on metal surface/metal frames/
wooden frames/wall/flap barriers including all mounting bracket & accessories complete etc. as required.
1.1 41.1.1 5" IPS TFT Touch Screen 1 Each 58,306.00 58,306.00
Software for Web based Access Control System Supplying, Installation, Testing and Commissioning of
Web based Access Control Enrolment and Device Configuration Software, Should be independent of
OS (Windows), Unified Management of Biometric, Card, and Controllers, Import Functionality for bulk
user details, Biometric Template Retrieval for Data Recovery, User Management, Logs and Terminal
Management, Support for IP-based and USB Biometric Devices, User-specific Access Policies, Different
2 41.5 User Policies on the Same Terminal, Assignment of Specific Access Schedules, Pushing Users to 1 Nos 97,176.00 97,176.00
Terminals or Groups, Admin Authority Management to define rights of each user to perform, Blacklist
User Management, Access Schedule Creation, Real-Time Log Retrieval, Real- Time User Identification,
Secure Storage of Biometric/Users Data, Capable to integrate with 3rd party applications over Web
API's, MQTT protocol support
Electromagnetic locks Supplying, Installation, Testing and Commissioning of Electromagnetic locks (fail
safe type) for following type of Doors suitable for operation on 12 V DC having holding force 600 lbs for
Single Leaf Door and 1200lbs for Double leaf door with suitable feedback i/c connection complete etc.
3.2 41.6.2 Double leaf door (Each leaf 600lbs & Total 1200 lbs) 1 Nos 7,593.00 7,593.00
Exit Push Button
Supplying, Installation, Testing and Commissioning of Heavy Duty SS Finish Exit Push Button for
releasing access doors with all necessary installation accessories i/c connection complete etc. as
Door Position Sensor Supplying, Installation, Testing and Commissioning of Door Position Sensor i/e
connection complete etc. as required.
Contractor 80 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUNATITIES:INTERGRATED ACCESS CONTROL SYSTEM
S No Item Description Qty Unit Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supply, Installation, Testing & Commissioning of Smart card Frequency Excitation (13.56 MHz) Mifare
smart Card , distance upto 2.5" Memory Type EEPROM, 2K bit memory Complies with ISO/IEC
standards for thickness. Lifetime Warranty .etc. as per specifications of this tender etc complete as
required and directions of Engineer-in- Charge.
Supply, Installation, Testing & Commissioning of 3 core 1.5 Shielded communication multi-stand Data
7 MR Cable etc. as per specifications of this tender etc complete as required and directions of Engineer-in- 30 Mtr 147.00 4,410.00
Contractor 81 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUQANTITIES: AUDIO VISUAL SYSTEM
DSR/ DSR NON-DSR
S No Item Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
SITC of 86" 4k, UHD Professional Signedge Display with 300 NITS, 24x7 ,Built in SOC/ Media
Playerwith Quad Core Processor, Built in Open Platform Android 11, 3X HDMI, Audio Input
Audio Output, Built in Speaker(12W x 2) ;Including mounting bracket, Built-in Chromecast,
1 MR Dolby Digtial audio HDMI-CEC device linking supported, 3 USB(2.0), 3*HDMI(2.0 Side), Nos 1 362,279.72 362,279.72
Headphone Out, 1 *RJ 45, SPDIF out, Built In 2.4 GHZ Wifi,CPU Built in Mali G31 MP2
GPU-A55*4, 1.1 GHz Processer, 4 GB RAM 32GB Storage,Metal Frame 12 W built speakers,
etc all required
SITC of Screen Size 75" Interactive display Pixel Pitch 0.429 x 0.429 mm, Resolution 3840
(H) x 2160 (V) 4K, Brightness ≤500 Nits, Contrast Ratio ≦4000, Viewing angle 178°,178°,
Response time 5ms, Display color 8 bit/16.7 Million, Backlight DLED,Speakers 2*15W etc all
SITC of Cable Cubby with flip top, cover and 6 Pass Through Holes for multi-format cables, 2
3 MR Universal Power Socket , 1 HDMI, 1 USB-C for Data Transfer, made of aluminium Nos 1 20,900.00 20,900.00
etc all complete etc all complete
SITC of Network PTZ Conference Camera, 12x optical zoom and 60° horizontal FoV, 1/2.8”
low-noise CMOS Sensor, Sensor Scanning Mode: Progressive, Horizontal Rotation Range:
±170°, Vertical Rotation Range: -30° to +90°, Image rotation for ceiling mounting, White
4 MR Balance: Auto, indoor, outdoor, one-push, manual, specified color temperature, IP Stream Nos 1 332,887.15 332,887.15
Resolutions: H.264 @ 360p, 270p or 180p, a single network cable for video, power and
control data transport, HDMI 2.0 and 3G-SDI Outputs Power Over Ethernet (PoE) support etc
SITC of professional-grade Presentation & Collaboration Switcher suitable for conference
rooms, boardrooms, AV environment with HDMI and USB-C connectivity, 2 HDMI Inputs, 2
USB-C connectivity (4K Video, Audio, Data, Power charge), 2 HDMI Outputs, 4 USB-A 3.0
5 MR Connection (for USB Devices), 2 USB-B 3.0 Connection (for PC hosts), USB host switching, Nos 1 303,675.51 303,675.51
Analog audio de-embedding, Charging via USB-C up to 60w, Supports HDMI 4K signal
formats (4K UHD @60Hz RGB 4:4:4, up to 18 Gbps), HDMI 2.0, HDMI 1.x, HDCP 1.x, HDCP
2.2 support etc all complete
SITC of Ceiling Tile Beamforming Microphone with Integrated DSP comprising minimum 128-
element MEMS microphone array with beamforming and advanced algorithms including AEC,
AGC, ANS, AFS, and reverberation reduction. The unit shall provide frequency response of
75 Hz to 20 kHz, 48 kHz/24-bit sampling, signal-to-noise ratio of 70 dB or better, and support
balanced analog and Dante network audio outputs. The microphone shall support 2 × 2 Dante
channels, RS-485 control, and 12 V DC / 48 V phantom power or PoE. The unit shall be
suitable for flush or suspended ceiling mounting and supplied complete with all required
SITC of Digital signalprocessor 6 balanced mic/line inputs and 1 unbalanced stereo auxiliary
input, 2 balanced outputs and 1 unbalanced stereo output, USB Audio I/O (for soft codecs),
7 MR Network (RJ-45) port, and Audio-Technica LINK (for cascading up to 8 mixers), Acoustic echo Nos 1 160,190.00 160,190.00
cancellation (AEC), 4-band parametric EQ and de-esser on each input, feedback
suppressors, and noise cancellation etc all complete
SITC of 6.5-inch, 2-Way Ceiling Speaker, Rated Power: 30W, Frequency Range: 65 Hz – 20
kHz, Sensitivity: 88 dB, Rated Coverage 135° conical DMT, Maximum continuous SPL 106
8 MR dB, Nominal impedance: 8 / 16 Ohm, Transformer taps: 30W / 15W at 100 / 70V, IP-34 Nos 6 23,202.17 139,213.04
Rated, Low-saturation and low-loss 70/100V transformers with 16Ω bypass, UL and CE
Certified etc all complete
SITC of 2 Channel Class-D Amplifier, Power (per channels driven): 200 W at 8 Ω / 4 Ω / 100V
/ 70V, FlexAmp Technology, Frequency Response: 20 Hz – 20 kHz, Signal to Noise > 103 dB,
Input impedance >10k, balanced or unbalanced, User-configurable operating modes, UL, CE,
RoHS/WEEE compliant etc all complete
Contractor 82 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUQANTITIES: AUDIO VISUAL SYSTEM
DSR/ DSR NON-DSR
S No Item Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
SITC of 2 Meter Premium High Speed HDMI 2.0b Flexy Cable, Bandwidth up to 18Gbps, Up
10 MR to 4096x2160@60Hz at RGB 4:4:4 video resolution, High Dynamic Range (HDR10), Dolby Nos 2 3,270.00 6,540.00
Vision and Hybrid log–gamma (HLG) video etc all complete
SITC of 10 Meter Active Copper HDMI Cable, Data Rate: Up to 18.2Gbps, Colour Depth: Up
to 16 bits, Colour Formats: RGB 4:4:4 / Y’CBCR 4:2:2 / Y’CBCR 4:2:0, Consumer Electronic
Control (CEC), Auto Lip-Sync Correction, Audio Return Channel (ARC), Enhanced Audio
Return Channel (eARC), High Dynamic Range (HDR) etc all complete
SITC of 2 Meter USB Full-Featured Type-C cable for USB 3.1 Gen2, 4 Lane Displayport Alt
12 MR mode (4K60FPS Video and Audio), Supporting peripherals via USB 2.0 up to 480 Mbps Nos 2 4,370.00 8,740.00
(Mouse, Keyboard, Thumb Drive, Speakerphone and Webcam) etc all complete
SITC of 10 Meter USB 3.1 Gen1 SuperSpeed Active Extension Cable TypeA/male to
13 MR TypeA/female, Supports 4K Webcam, SSD storage, Native USB2/USB1 and USB3 extension, Nos 1 24,452.90 24,452.90
Plug and play compatible with PC, Mac, and Linux etc all complete
SITC of 2 Conductor 16 AWG Speaker Cable, stranded Bare copper conductors, PVC/Nylon
insulation, PVC jacket (as per actual) etc all complete
SITC of Mirophone cable PVC/Nylon insulation, PVC jacket (as per actual) etc all complete
16 MR SITC of Category 6A Cable, 4 Pair, S/FTP, PVC jacket (as per actual) etc all complete Metre 50 95.00 4,750.00
17 MR SITC of Various Cables, relay modules & Connectors etc all complete Nos 3 15,181.45 45,544.35
Contractor 83 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULEOF QUANTITIES: LIFT
Refer DSR- Rate DSR NON-DSR
S No Description of Item Unit Quantity
All Figure are in Rs. All Figure are in Rs.
Supplying, Installation, Testing & Commissioning of following capacity passenger Machine
room less (MRL) lift with regenerative drive as per CPWD General Specification for
Electrical Works (Part-III Lift & Escalator) 2003, BIS Codes, NBC 2016 as amended upto
date having provision for barrier free access as per Harmonised Guidelines & Standards for
Universal Accessibility in India - 2021 of MoHUA, serving different floors in the lift shaft as
per detailed specifications enclosed and as under including all other equipment and
accessories complete as required:-
(i) Speed-1 MPS
(ii) Floors-7 (2B+G+4)
(iii) Travel -30 Meters (approx.)
(iv) Stops & opening- 7 stops and 7 openings
(v) Controller: A.C. variable voltage & variable frequency
(vi) Automatic rescue device (ARD) complete with dry maintenance free batteries as
1 vii) Operation: Microprocessor based single automatic push button/simplex selective
collective/duplex collective selective with/without attendant
(viii) Power-415 Volts+10%, 3 phase, 50 Hz, 4 wires system
(ix) Car Enclosure: Stainless steel scratch proof (Moon Rock/Honeycomb/ Hairline Finish)
on all sides and stainless steel decorative ceiling with fans (indirect throw) and LED fitting.
(x) The car flooring should be smooth and antiskid as approved by engineer-in-charge.
(xi) Type of doors (a) Car: Power operated, centre opening horizontal sliding stainless steel
scratch (MoonRock/Honeycomb/ Hairline Finish).
(b) Landing doors: stainless steel scratch proof.
(xii) A hand rail not less that 600mm long at 900mm above floor level to be fixed adjacent to
control panel in the lift car.
(xiii) Voice announcement system in the car toannounce the position of the elevator in the
hoist way as the car passes or stops at floor served by the elevator.
(xiv) Closed loop Control System, protection against power fluctuation, self diagnostic
control, Landing doors 2 hours Fire rated, Overload detection and protection, Overspeed
Governer, Dot Matrix LED D&P Indicators In Car & Landings, BMS Compatibility, tamper
proof infrared curtain covering almost the entire height of the lift car door, Alarm horn, Anti
Nuisance Operation, CCTV camera system with 4 MP IP camera, suitable NVR and HDD
for 30 days storage backup , Firemen switch, 2/3 way intercom, Emergency Stop Switch
with battery backup for fan and light fitting for 1 hour, pit ladder.
(xv) The lift doors shall have a vision panel to enable persons with hearing impairment to
signal for help or assistance in the event of an emergency.
(xvi) An appropriate technological support be provided (Through emergency messaging
|services or alarms etc.) to respond to the emergency requirements of person with hearing
impairment or deafness.
(xvii) In case of failure of ARD or other electronic devices, a provision of manual rescue be
Contractor 84 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULEOF QUANTITIES: LIFT
Refer DSR- Rate DSR NON-DSR
S No Description of Item Unit Quantity
All Figure are in Rs. All Figure are in Rs.
Incomer: 1nos 63A, 300mA 4P ELCB.
1nos 32A TPN MCBs
2nos 16A DP MCB
board complete as above Each 3 61065.00 183195.00
Contractor 85 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: BUILDING MANAGEMENT SYSTEM
E&M S No DESCRIPTION OF ITEM UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
CENTRAL CONTROL SERVER Supplying Installation Testing Commissioning of
Central Control Server System comprising of Intel® Xeon® CPU E5-2640 x64 (or
better) compatible with dual and quad core processors, Windows 11 (Professional,
Enterprise, Ultimate, 64 bit), Windows Server 2013 R2 (Standard, Enterprise, 64 bit)
42.1 1 16 GB or more, Video card and monitor capable of displaying at 1024 x 768 resolution Each 1 186,434.00 186,434.00
or better, Latest Microsoft Licence Version Operating System Loaded with MS
OFFICE 2019 Professional, Word, EXCEL, Power Point, Outlook Express, Microsoft
Team official version lifetime licences suitable for running BMS software complete etc.
PC System Supplying Installation Testing Commissioning of Client PC System
comprising of PC Hardware with minimum11th Gen Intel® I7 processor CPU E5-2640
x64 (or better), compatible with dual and quad core processors minimum 3.1 Ghz and
42.2 2 8GB or higher RAM, Hard Drive Space of 256 GB SSD or better, Video card and Each 1 90,698.00 90,698.00
monitor capable of 1920 x 1080 pixel resolution or better with Ethernet adapter
(10/100/1000 Mbps with RJ-45 connector) with 2 GB or higher Graphics card suitable
for BMS System complete etc. as required.
LaserJet printer Supplying Installation Testing Commissioning of LaserJet printer
42.3 3 having printing resolution 1200 x 1200 dpi, (dot/inch) or better, 21 to 30 ppm printing Each 1 22,674.00 22,674.00
speed (LaserJet) complete etc. as required
Supplying, Installation, Testing and Commissioning of following size LED display (LED
monitor) industrial grade with 3840x2160 resolution or better, USB playback, bluetooth
and miracast connectivity, 4X HDMI 2.0, DP 1.2, HDR 10/10+, brightness: 500-nits
Software for Building Management System : Supplying Installation Testing
Commissioning of Necessary Software (UL listed) Packages containing Building
42.5.1 Management
For Upto 500 with
pointCapability
included of Collection, Storage, Processing and Controlling all the Each 1 97,377.00 97,377.00
Contractor 86 NBCC
Digitally signed by DEEPAK
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: BUILDING MANAGEMENT SYSTEM
E&M S No DESCRIPTION OF ITEM UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
DDC CONTROLLERS Supplying Installation Testing Commissioning of IP Based
DDC controller capable of fully “stand- alone” operation i.e. In the event of loss of
communication with other DDC’s or Control Station, they shall be able to function on
their own. The controllers shall consist of dual/quad core 32 bit microprocessors with
EPROM based operating system on BACNET. The network Topology shall not allow
single point failure. Each DDC on field level shall have embedded TCP/IP
(10/100Mbps) connectivity so that it can be hooked into the Local Area Network (LAN)
provided by the client or on dedicated network . Each DDC can be accessed from the
Graphical User Interface (GUI) or from a standard Web browser (WBI) by connecting
the server alongwith inbuilt web browser. All controllers shall accept 230V+/- 10%,
50Hz Uninterrupted power supply provided by end user. Controller shall support
42.7 6 DHCP addressing over Local Area Network (LAN) so that the static IP requirements
get reduced however a single static IP shall be provided for system so that it can be
hosted on to internet in consultation with end user. The microprocessor based DDC’s
shall be provided with power supply, analoge to Digital and Digital to analoge
converters with memory and capacity to accommodate input/output (I/O) hardware
points (with or without an expansion board). Each DDC should have own board and
shall accept 0-10 V /4-20mA input signal having Minimum 20% sparecapacity
considered for expansion. Each DDC on fieldlevel should have minimum 128MB RAM
& 64MBFlash memory. Following type of All controllers should be mandatorily BTL
approved with B-BC profile complete etc. as required.
42.7.1 a DDC Controller-Type-I (support upto 32 points) Each 12 46,861.00 562,332.00
Field Devices -Supplying Installation Testing Commissioning of following Field
Devices including connection etc. as required
42.11.1 a Water Differential Pressure (DP) Switch for Pump Status. Each 6 9,690.00 58,140.00
42.11.2 b High/Low Level Switch for Tank Level Monitoring. Each 4 7,904.00 31,616.00
42.11.3 c Air DP Switch for Fan Run Status. Each 4 2,928.00 11,712.00
Outside Temp & Humidity Sensor with radiation shield. Measuring Range: Temp:- -15
42.11.9 e Current Sensing Relay Each 10 3,174.00 31,740.00
42.11.10 f Wall Mount Temp. Sensor Each 4 6,550.00 26,200.00
42.11.1 g Wall/Ceiling Mount CO Sensor Each 4 8,314.00 33,256.00
42.11.14 h Water level sensor Each 10 6,621.00 66,210.00
42.11.16 i Water flow switch Each 4 3,779.00 15,116.00
Contractor 87 NBCC
Digitally signed by DEEPAK
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: BUILDING MANAGEMENT SYSTEM
E&M S No DESCRIPTION OF ITEM UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
Integration of the below mentioned Equipments:
Necessary data exchange hardware/ software points units required to integrate the
below third party systems and to convert to open protocol MQTT, MODBUS vendor to
accommodate the software address required for integration. Any additional hardware
required to complete the integration for both read-write provisions shall be in the
scope of below equipment provider
MR a Variable Air Volume Lot 1 555,429.00 555,429.00
MR b Energy Meters Lot 1 108,923.00 108,923.00
MR d Fire Alarm System Integration Lot 1 79,103.00 79,103.00
Supply, installation, testing and commissioning of Wall Mount Indoor Enviroment
Monitoring Sensor; BMS/IoT compatible.
Measurement Parameters:
- Temperature: -40 to 80 °C, Accuracy ±0.5 °C, Resolution 0.01 °C
- Relative Humidity: 0–100% RH, Accuracy ±3% RH, Response <8 sec
- CO₂: NDIR, 0–2000 ppm, ± (50ppm + 5% of reading)
Electrical & Mechanical: 9–24 V AC/DC, ≤340 mA @ 24 V AC, Reverse/Overvoltage
protection, ABS plastic enclosure, IP20, Wall mount
Communication Interfaces: Modbus RS-485 / Modbus TCP (Wi-Fi)
Compliance: UL or CE compliant
Contractor 88 NBCC
Digitally signed by DEEPAK
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: BUILDING MANAGEMENT SYSTEM
E&M S No DESCRIPTION OF ITEM UNIT QTY RATE
All Figure are in Rs. All Figure are in Rs.
Supply, installation, testing and commissioning of Wall Mount Indoor Air quality
sensor; BMS/IoT compatible.
Measurement Parameters:
- Temperature: -40 to 80 °C, Accuracy ±0.5 °C
- Relative Humidity: 0–100% RH, Accuracy ±3% RH
- Carbon Dioxide: NDIR, 0–2000 ppm
- Carbon Monoxide: 0-500 ppm
- Total Volatile Organic Compound: 0 - 99999 ppb
- Nitrogen Dioxide: 1 - 500 Index
MR b - Sulphur Dioxide: 0 - 20 ppm Each 6 85,000.00 510,000.00
- Ozone: 0 - 10 ppm
- Formaldehyde: 0 - 3 ppm
- Particulate Matter 1.0: 0.3 to 10μm
- Particulate Matter 2.5: 0.3 to 10μm
- Particulate Matter 10: 0.3 to 10μm
Electrical & Mechanical: 9–24 V AC/DC, ≤340 mA @ 24 V AC, Reverse/Overvoltage
protection, ABS plastic enclosure, IP20, Wall mount
Communication Interfaces: Modbus RS-485 / Modbus TCP (Wi-Fi)
Compliance: UL or CE compliant
Contractor 89 NBCC
Digitally signed by DEEPAK
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: OCCUPANCY SENSORS AND CURTAIN REMOTE CONTROLS
S No 2025/ Description Unit QTY Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Description Supplying, Installation, Testing and commissioning of Passive
Infrared (PIR) technology based occupancy sensor having high performance,
non regulating programmable type, suitable for connected load upto 10Amp ,
for mounting height up to 3 meter and for 5 m diameter coverage area along
with necessary fixing arrangements i/c programming at site etc. complete as
Supplying, Installation, Testing and commissioning of Passive Infrared(PIR)
technology based occupancy sensor with day light dimming(lighting level shall
be regulated as per availability of natural day light in an area along with
occupancy detection) having high performance, regulating programmable
suitable for connected load upto 10Amp , for mounting height up to 3 mtr
and for 5 m diameter coverage area along with necessary fixing
arrangements i/c programming at site etc. complete as required.
Supplying, Installation, Testing and commissioning of Astronomical time
switch of following configuration to be mounted in feeder pillars / Lighting DBs
for automatic switching On & OFF of street lights at sun set & sun rise or
twilight(Auto ON, Auto OFF, Auto modes) with manual override facility with
12/24 hour display format with suitable battery and indication for relay status
i/c programming at site complete as required.
7.4.3 3 output(1output per phase) and suitable for three phase supply Each 4 11,161.00 44,644.00
Contractor 90 NBCC
Digitally signed by DEEPAK
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SOLAR PHOTOVOLTAIC POWER PLANT
S No Item Description Unit Qty. Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Supplying Installation, Testing and Commissioning of on-grid Solar Photovoltaic Power Plant
conforming to various applicable standards BIS, IEC, MNRE guidelines, the Central Electricity
Authority Regulations and CPWD Specifications as amended up to date, consisting of
Mono/Poly Crystalline silicon solar cells module, net metering facility, necessary control,
protections, earthing, cabling, mounting structure, junction boxes, power conditioning units, Real
time online web interfaced Data Monitoring System, Distribution panels, grid connecting
arrangement, conduits, pipes, cable trays and other accessories etc. as required.
High Energy Efficiency Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in
India, conforming to IS 14286/IEC 61215, IS/IEC 61730- Part-1, IS/IEC 61730-Part-2. Solar
Photovoltaic Module conversion efficiency shall not be less than 23% at STC with temperature
coefficient of Pmax better than -0.30% per 0C. PV modules used in solar power plants/ systems
must be warranted for their output peak watt capacity, which should not be less than 90% at the
end of 10 years and 80% at the end of 25 years. Solar Modules shall be designed to operate in
relative humidity upto 100% with temperature between -10 0C and +85 0C. Further, each PV
module used in any solar power project must have Radio frequency identification tag with
information such as name of manufacturer, month and year of manufacturing, country of origin
(separately for Solar cell and module), I-V curve, Unique Serial No and Model No of the module,
Wattage, Im, Vm and FF, name of test lab issuing IEC certificate.
Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 415 V AC, three
phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC with a variation of 10% at
nominal voltage. Power with efficiency not less than 97%, total harmonic distortion less than 3%
and suitable for ambient temperature from 0 to 50 0C, Minimum IP-65 for outdoor and Minimum
IP 21 for indoor, Built-in 91 DELHI SCHEDULE OF RATES (E&M)-2025 meter and data logger,
MPPT, switching devices IGBT/MOSFETs and controller Microprocessor /DSP. PCU/inverter
shall be capable of complete automatic operation including wake-up, synchronization &
shutdown. The PCU shall be able to withstand unbalanced load conforming to IEC standard with
B shutdown/standby mode. It must be provided with grid islanding along with manual disconnect
pole isolation switch besides automatic disconnection. Minimum protections: Mains Under / Over
Voltage, Over current, Over/Under grid frequency, Over temperature, Surge voltage induced at
output due to external source, Short-circuit, Lightening, Anti Islanding (for grid synch. Mode) and
1 other protections as per applicable standards. LCD/LED display of minimum parameters: DC
input voltage, DC current, AC Voltage and current (all 3 phases, in case of 3 phase),
Instantaneous & cumulative AC output power, Daily DC energy produced and other parameters
applicable standard. Communication interface RS 485 / RS 232.
Module mounting structure: The roof top solar plant generation units shall be installed by using
supporting Aluminium/Galvanized MS structure (mass of zinc coating shall be as per IS4759 )
having minimum head room clearance of 2.4 meter above the terrace level / ground level. The
mounting structure would be designed to sustain wind load and seismic parameter of the site of
C installation. All the structure shall be design as per applicable BIS code and the material shall
also confirm the applicable BIS Code. Structural material shall be corrosion resistant and
electrolytically compatible with the materials used in the module frame, its fasteners, nuts and
bolts. The suitable arrangements for maintenance and cleaning shall be provided.
Real time online web interfaced Data Monitoring System complete with accessories for various
parameters such as Solar Irradiance, temperature, AC Output Voltage and current, Output
D Power, Power factor, DC Input Voltage and Current, Time Active, Time disabled, Time Idle,
Power produced and other parameters as per standard practices.
Contractor 91 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SOLAR PHOTOVOLTAIC POWER PLANT
S No Item Description Unit Qty. Rate DSR NON-DSR
All Figure are in Rs. All Figure are in Rs.
Array junction box & Main junction box with IP 65 protection and termination arrangement for
incoming and outgoing cable along with glands, lugs and other 92 DELHI SCHEDULE OF
RATES (E&M)-2025 accessories etc. as required. Each junction box shall be made of
E GRP/FRP/Powder Coated Aluminium /cast aluminium alloy with full dust, water & vermin proof
arrangement with High quality Suitable capacity Metal Oxide Varistors(MOVs) (semiconductor
diode with resistant applied voltage)/ surge arrestors and suitable Reverse Blocking Diodes,
isolation switches isolate the DC input to Inverter, copper bus bar etc.
F Lightning, surge voltage protection, earthing protection and grid islanding.
Cables: Connections & Interconnections by required size IR/UV protected XLPE insulated
copper conductor 1.1 kV grade armored power and control cables(ISI Marked) along with
supplying & fixing of necessary channel/conduit, GI cable trays, supports, lugs, thimble and other
accessories etc. as required.
DC Distribution Board And AC Distribution Panel Board: IP65, free standing, metal cladded,
H having copper bus bar, having required protection and control gears, connection- KWp 30 54280.00 1628400.00 0.00
interconnection, etc. as required.
Parkbay DC Charger (Mode-3) Power Level 2: Normal Power ~24KW and above, 3 phase
415VAC(-40% to +20%), Frequency:50 Hz +/-5%, output supply: DC 12/24 Volt, Operational
temperature range : -25 to 55 0C (outdoor), -5 to 55 0C (Indoor), RH upto 95%, Charging Device
as per Device/protocol: IS-17017-23, EV-EVSE Communication as per IS-17017-24, ISO 15118,
Infrastructure Socket as per IS-17017-2-2/3, Vehicle Connector as per IS-17017-2-3 Vehicle
Inlet/ Connector As per EV manufacturer, suitable for 4 wheelers. Indoor use: at least IP42;
Outdoor use: at least IP54. Mechanical Strength: protection of the external enclosure against
2 18.1.4 mechanical impact shall be IK08 according to IEC 62262. O/L,S/C protection. Insulation
Resistance > 1 M Ω. Cable Length: 7.5 m. RCD having a rated residual operating current not
exceeding 30 mA; Separate RCD for multiple outputs. Telecommunication port of the EV supply
equipment according to IS 13252 (Part 1) : 2010.
OCPP(Open charge point protocol) 1.6J upgradable to ocpp 2.0. Device Should follow 17017
series of IS codes in general and the installation of the system shall comply with relevant IS
Total of Solar & EV Charger Works 1,628,400.00 0.00
Contractor 92 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SEWAGE TREATMENT PLANT (STP)
DSR/ DSR NON-DSR
S No Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
Design, Supplying, Installing, Testing & Commissioning of Sewage Treatment Plant capacity 20 KLD. The plant proposed shall
be 20 KLD with a main pump room. The plant is proposed to be installed in the basement accessible from the pump room itself
for future maintenance. No opening shall be provided on main slab above for this purpose, for the following :
Nature of effluent - Domestic Sewage from Toilet use and kitchen waste.
Daily average out flow - 20 Cum / Day
BOD5 - upto 250-350 Mg/L
S. Solids - 250 - 400 Mg/L
COD - upto 450-600 Mg/L
Oil & Grease - 50 Mg / L
Effluent discharge standard after treatment
BOD5 - Less than 10 Mg/L
S. Solids - Less than 10 Mg/L
COD - Less than 50 Mg/L
Oil & Grease - Less than 5 Mg/L
Turbidity -Less than 2–5 NTU
1 MR Phosphate- Less than2 Mg/L
Total Nitrogen- Less than 10 Mg/L
Sewage treatment plant shall include the following items:
Sewage equalization tank/sump
Disinfection Chember
Treated Water tank
Sludge Holding Tank
Filtration through MGF & ACF
Air Blowers, Pumps & equipment
Piping, valves etc
Electrical Panel & Cabling
Common plant room adjacent to STP.
Ultra Filtration (U.F) Systems
Softener as optional
Soft water tank as optional
All piping, valves & level indicator/controller etc. within plant room.
Supply, installation, testing & commissioning of 1 Nos Stainless Steel Perforated Screen with suitable lifting arrangement (size
1.1 MR Set 1
600 mm wide x 600 mm high approx)
Raw Sewage Lifting pump
Supply, installation, testing & commissioning of non clogging type pumps, having CI casing & CI impeller complete with all
accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation
cock level controller with wiring to control the level of sump automatically. Pump shall have following duty.
Submersible Sump Pumps (2 Nos. - 1 working & one standby) :Raw Sewage Lifting pump
(Solid handling cap. 30 mm)
Flow rate (each) = 4m3 / hr
Head = 6-7 Mtr Set 1
Contractor 93 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SEWAGE TREATMENT PLANT (STP)
DSR/ DSR NON-DSR
S No Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
1.3 Sewage Lifting Pump
Supply, installation, testing & commissioning of non clogging type pumps, having CI casing & CI impeller complete with all
1.3.1 MR accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation
cock level controller with wiring to control the level of sump automatically. Pump shall have following duty.
Submersible Sump Pumps (2 Nos. - 1 working & one standby) :Sewage Lifting Pump
(Solid handling cap. 30 mm)
Flow rate (each) = 4m3 / hr
Head = 6-7 Mtr Set 1
1.4 Drainade Sump Pump For Plant Room.
Supply, installation, testing & commissioning of non clogging type pumps, having SS casing & CI impeller complete with all
1.4.1 MR accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation
cock level controller with wiring to control the level of sump automatically. Pump shall have following duty.
Plant room sump pump 2 Nos (1 working + 1 standby)
Flow rate of each = 10 cum/hr
Head = 14Mts Set 1
(Solid handling size for this pump shall be 7 mm).
1.5 Sludge Transfer surface mounted Pumps
Supply, installation, testing & commissioning of non clogging type pumps, having CI casing & CI impeller complete with all
1.5.1 MR accessories, motor of required capacity. Delivery header with isolation valve, pressure gauge on delivery line with isolation
cock level controller with wiring to control the level of sump automatically. Pump shall have following duty.
Sludge Transfer surface mounted Pumps (2 Nos. - 1 working & one standby) :-
(Solid handling cap. 7 mm)
Flow rate (each) = 2 m3 / hr
Head = 10 Mtr Set 1
1.6 Air diffusion system shall include the following:
Twin type rotary air blowers One working & one standby) capable of delivering 80 cum/hr (each) of free air at 0.4 kg/cm2
1.6.1 MR driven through “V” belt or directly coupled through flexible coupling to a TEFCmotor of suitable HP Suitable for 415 ± 10% Set 1
volts, 3 phase, 50 cycles a/c supply(1W+1S)
Air piping shall comprise of pipes droppers/ laterals with M.S "B Class" (epoxy coated) Header complete with all fittings such Included in System
1.7 MR Lot 1
as tees, crosses, plugs, sockets, elbows, reducers, supports & clamps, puddle flanges etc Piping
Non clog type air dispersion system capable of handling 3-5 cfm of air with oxygen transfer efficiency of 3-4% per/meter
1.8 MR water depth. Air dispersion grid shall be assembled in modular form so that they can be replaced / repaired
1.9 Fine bubble diffusers
a) For equalization tank -1 Job.
b) MR For sludge holding tank - 1 Job.
c) MBBR reactor tank- 1 Job. Lot 1
Note : Air dispersion system shall be provided for Equalisation Tank, Sludge holding Tank and MBBR reactor Tank.
Providing and fixing all piping (as described below) and isolation control valves for making the system complete.
PVC : Submerged air piping
MS Epoxy : Air piping
PVC piping : Pumped effluent & tank overflow pipe line Job 1
Contractor 94 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SEWAGE TREATMENT PLANT (STP)
DSR/ DSR NON-DSR
S No Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
Bio deck MBBR Media
Supply, installation, testing and commissioning of PVC Bio deck MBBR media to be installed in MBBR Tank (1No.) and PVC
1.11 MR tube deck settling media to be installed in Secondary Settling Tank alonwith suitable sludge removal arrangement either by Job 1
pumps or air lifting pumps
Tube Settler Media:
Instalation Testing and commissioning providing PVC tube deck media to be instaled in seconday setteling tank along with
1.12 MR Lot 1
sutable sludge removal arrangment.
Supply, installation, testing & commissioning of Chlorine Dosing pumping systems Job 1
Make : E- Dose/Initiative (1W+ 0S)
Capacity : 0-6 LPH
Tank : 100 Ltr HDPE
Supplying, installing, testing & commissioning of centrifugal filter feed water pumps SS Body, SS Impeller with mechanical
seal along with motor. Pressure gauge with isolation cock, NRV, Isolation valve on delivery line. Isolation valve, stainer at
suction. The pump shall be suitable for 415 ± 10% volts, 3 phase, 50 cycles a/c supply
Capacity : 3 M3/hr.
No. of Pumps (1 working + 1 standby) Set 1
Operation of pump shall be based on level controller proposed to be installed in tank as per site location. The contractor to
ascertain the Head required for pumps as per site conditions and provide accordingly.
Supplying, installing, testing and commissioning of FRP vessel filter with MPV and associated valves and accessories. Filter
1.15 MR shall be suitable for minimum working pressure of 2.5 kg / cm2 and shall include media, standard fittings like pressure.
Multigrade pressure sand filter media
Flow rate : 3 cum/hr
1.15.1 MR Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 600 mm. Set 1
Oprating Pressure: 3.5 Kg/Sqm
Activated Carbon Filter
Flow Rate : 5 cum/hr
Filteration velocity : 15 cum/hr/sqm
Filter Diameter : 600 mm Set 1
DIGESTED SLUDGE DISPOSAL PUMP:
Providing and fixing horizontal, centrifugal sludge disposal pump for the disposal of sludge to tanker or to sludge dry beds.
The pumps shall have CI casing, bronze impeller &SS shaft & sleeve with mechanical rotary shaft seal connected by a flexible
MR tier type coupling to TEFC induction motor mounted on a common channel base-plate with coupling guard, 150 mm dia
pressure gauge with GM isolation cock, suitable vibration eliminator pads of approved design .Motor to be suitable for including
all necessary piping to feed filter press/ outlet upto ground level for feeding vehicle, valves and other accessories and concrete
foundation complete as required.
Capacity 5m3/hr @ 2 m head (1W+0S) Set 1
Supply, installation, testing and commissioning of Filter Press of plate size 12"x 12" x 11 plate with screw feed pumps for
1.17 MR Set 1
required capacity (1Working) with interconnecting piping and poly dosing system all complete.
Contractor 95 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: SEWAGE TREATMENT PLANT (STP)
DSR/ DSR NON-DSR
S No Description Unit Qty Rate
MR All Figure are in Rs. All Figure are in Rs.
1.18 MR Magnatic Flow Meter at treated water outlet. No 1
Electrical cable and cable trays
1.19 MR Supply instalation testing commisioning of electrical cable,cable trays and cable trenches , compleet with lugs,
cableglands,conducting pipesand all other accessories,cabling shall be down from all the equipment to the master control set 1
panel compleet in all respect. GI Earting strip from all the eqiupment to the master control panel is also included.
Instrumentation / pressure gause/ Level switch set 1
SITC of the 2 m³/hr Ultrafiltration (UF) System: System shall be designed, manufactured, tested, supplied, installed, and
commissioned to produce 2 m³/hr of treated water. The system shall include UF membrane modules, pumps, piping, valves, set 1
instrumentation, control panel, skid, accessories, and all necessary interconnections for complete operation.
Raw Water Tank → Feed Pump → UF System → Permeate Tank, Backwash Line: Permeate Tank → Backwash Pump → UF
Membrane,Chemical Cleaning: CIP Tank → CIP Pump → UF Membrane
Plant Capacity: 2 m³/hr, Type of Process: Pressure Driven Ultrafiltration, Membrane Material: PVDF Hollow Fiber, Membrane
Pore Size: 0.01 µm, Filtration Mode: Outside-In, Operating Pressure: 1–3 bar, Design Pressure: 4 bar, Recovery: ≥ 90%,
Operating Temperature: 5–40°C, Feed Water Source: Surface Water / Borewell / Municipal Water, Power Supply: 415 V AC, 3
UF Unit: 2 m3/hr. UF Skid: MS No 1
UF Feed Pump: 4 m 3/hr. @ 25 m MOC –CI. No 2
UF Backwash Pump: 5 m3/hr. @ 25 m, MOC-CI No 1
UF Membrane: 8” x 72” Make: Deerfos/Grafil/Eqv No 1
Dosing System0 – 6 LPH No 1
1.20 MR Air Blower: 10 cmh @ 0.3 kg/cm2 No 1
Micro Screen Filter No 1
100 amps TPN MCCB with the following accessories:
a. 0-500 volts 96 x 96 mm square electronic voltmeter with selector switch shall be protected by 2 amps TP MCB. 1 Set
b. 0-100 amps 96 x 96 mm square electronic ammeter with selector switch and 100./5 amps 10 VA CL:1 CTs. 1 Set
c. Phase indicating lamps shall be protected by 2 amp SP MCB 3 Sets
300 amps TPN (15 KA) copper bus bar with heat shrinkable insulation sleeves.
a. Required Nos of required capacity TPN MCB for direct on line starter/star delta starters and out going feeders to all the
pumps/blowers etc. (including standbies). Each compartment shall contain auto / manual selector switch and indicating lamp
with MCB’s for ‘ON/OFF/TRIP’ status of motor
b. Spare MCB’s of following capacities:
i. 32 amps TPN MCB’s 6 Nos. or as per load & oprational logic
c. Necessary cable alleys, internal / cabling, wiring, cabling from MCC to various pumps / equipment and interlocking, earthing
for all equipment shall also included
Notes : a. All MCCBs / MCBs shall be of 15 KA breaking capacity and suitable for motor duty application.
b. All motor starters shall be provided with Automatic level controller
c. DOL starters shall be used for mototrs below 5HP and Star-Delta Starters for other motors .
d. Provision shall be made for providing potential free contacts to all pumps starters
1.21 MCC for all STP equipments/pumps as described in sub head II Job 1 3,970,605.00 3,970,605.00
Contractor 96 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES - RO PLANT
DSR E&M DSR NON-DSR
S NO DESCRIPTION UNIT QUANTITY RATE
2025/ MR All Figure are in Rs. All Figure are in Rs.
SITC of food grade Stainless Steel water cooler with cooling
A.1 MR capacity of 40 litres per hour and storage capacity of 80 litres Each 5 132986.00 664930.00
with hot and cold faucet dispenser
Supply, Installation, Testing and Commissioning of 500 LPH RO
A.2 MR system along with 1000 Ltr SS storage tank as per attached Each 1 997395.00 997395.00
technical above
Contractor 97 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: BOOM BARRIER
DSR/ DSR NON-DSR
S No Description Unit Qty Rate
All Figure are in Rs. All Figure are in Rs.
SITC of Electromechanical automatic barrier, for 6
m access points. Dimensions 220 x 340 x 1 040
mm, self-supporting steel structure, with
protective cataphoresis treatment and powder
coating RAL 7015; degree of protection IP54. Built-
in control unit housed in the top section of the
Operating temperature ranging between -20°C and
+55°C. Usage frequency for 6m boom 2 000
1 MR operations/24h. MCBF: 3 000000 cycles 24 V motor Each 2 268,000.00 536000.00
lubricated with permanent grease. Barrier supply
voltage 110V 50/60Hz, or 230V 50/60Hz. Absorbed
electric motor power 300 W.
Adjustable opening & closing time 2.2 to 4 sec.
Impact reaction through an encoder. Balancing by a
spring included in the barrier. Manual release with
custom key. Including Loop Detector, 2 Channel
Remote and Push Button
TOTAL 536000.00
Contractor 98 Digitally signed byNBCC
Tender for appointment of Contractor for "Construction of Central Bank of India Office Building at Amaravati, Andhra Pradesh"
SCHEDULE OF QUANTITIES: FURNITURE
S No DSR/ MR Item Name Description Quantity Rate
All Figure are in Rs. All Figure are in Rs.
Regional maneger Room Table & Side Table
Overall Size : W 2100 x D 1000 x H 750mm & Side Unit Extention: W 1400 x D 550 x H 750mm. Table
Top: 25mm thick pre laminated particle board with 2mm PVC edge lipping supported on V Shape
aluminium die cast connectors of min size 430 mm L x 110 mm H x 25 mm Thick. 4 Connectors on Main
table & 2 on side unit shall be provided. All sides of the worktop except corners of main & side table shall
be provided with 2mm thick alumimum extrusion of 40mm + 25 mm + 30 MM + 8 mm formed into
horizontal & vertical direction to enable support as well as top surface coverage. edge surface extrusion
supporting the worktop to be tappered towards top. Support: End Legs: 50mm thick pre laminated particle
board with 2mm PVC edge lipping & 3 equal drawer pedetal size of 600 x 850 x 570mm (LDH). Modesty
Panel: 18mm thk pre lam board with 2mm PVC edge lipping of 450mm Ht. Wire Management: 65mm dia
Cabin Table wire manager grommet on table, flip up and provision to place CPU in side extension drawer. Sufficient
1 MR storage space to be priovided in the storage pedestal of the table having drawers at the main table & 1 235,514.00 235,514.00
hinged door storage below the side unit. The main and the return table top will have 10 mm thick Euro
bronze glass with white vinyl film hot laminated and Kuraray pvb interlayer. Back Unit Overall Size W 1500
x D 600 x H 750mm, Table Top: 25mm thick pre laminated particle board with 2mm PVC edge lipping
sides covered with 2mm thick anodised alumimum extrusion of same size as above supported on V Shape
aluminium die cast connectors of same size as above. Back: 25mm thick pre laminated particle board with
2mm PVC edge lipping with aluminium die cast arms Shutters: 25mm thick pre laminated particle board
with 2mm PVC edge lipping with brush steel handles and softclose drawer slides and hinges. The back
unit table top shall also have 10 mm thick Euro bronze glass with white vinyl film hot laminated and
Kuraray pvb interlaye
The overall size of table shall 2000L x 800D x 780H with Side Unit Extention 1010L x 500D x 650H. The table top shall
be made of 25mm thick with Pre laminate Partical board with all side 2mm pvc edge band finish. The working table top
shall have size of 1800L x 800D. The table top visible side shall be 50mm thick. The edge of table top shall be cover
with L-shaped alumimum extrusion with size of 10mm x 15mm.This aluminium extrusion shall increase the overall look
of the table top.The main table top shall be supported on one side top supported pedestal and other side of side unit. 3
equal drawer unit shall be provided with size of 495 W x 800D x 650H. The drawer unit shall be made of 18mm thick
pre laminate partical board with 2mm pvc edge band finish.The front modesty shall be made of 18mm thick pre
laminate Partical board with 450mm height. Modesty shall be fitted on gable end with helps of mini fix. Wire
Management: 1 No. Aluminium Flip Up and provision to mount swicthes and sockets on metal cable Dump and
vertebra considered for wire uptake from floor to cable dump. Side return unit shall have overall size of 1010L x 500D x
Cabin Table 650H.The body of side unit shall be made of 18mm thick pre laminte Partical board with 2mm PVC edge band
2 MR finish.The side table design should be such that it has flexibility to be fixed either in right hand side or left hand side of
the user during the time of assembly. The side unit shall have one openeble shutter with 2 equal compartment to keep
the documents and rest area shall have open compartment. The overall size of Back unit shall be 1800L x 400D x
2000H. The back unit top shall be made of 25mm thick pre laminate partical board with 2mm pvc edge band on all the
side. The side pannel shall have made of 18mm thick pre laminate partical board with 2mm pvc edge band finish all the
visible side. The storage consist of 2 openeble door with size of 450W x 1940H and 2 openable shutter with height of
780mm at the floor level. In middle of the storage shall have openable compartment and the shelf of openable
compartment shall be made of 25mm thick pre laminate partical board with 2mm pvc edge band in the viasible side of
shelf. The door shall be operated by leatherette strip handle. The OEM shall have ISO 9001, BIFMA Level 2, Green
Guard UL Gold Certification, AIOTA, IGBC Gold rated factory certification and India Design Mark.
Contractor 99 Digitally signed byNBCC
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT Central Bank of India Amaravati.pdf
Tender Document
SCC- CBOI.pdf
Tender Document
GCC for Construction Works 2026.pdf
Tender Document
Integrity Pact.pdf
Tender Document
Physical Milestones - Central Bank of India Amaravati.pdf
Tender Document
Tender BOQ- CBOI.pdf
Tender Document
Tender Drawings - CBOI.pdf
Tender Document
Techncial_Circulars.pdf
Tender Document
Technical Specifications-CBOI.pdf
Tender Document
Approved Makes List - CBOI.pdf
Tender Document
Geotechnical Investigation Report - CBOI.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].