Executive Engineer PWD BDN ELEC DIVN
Room no 1081st fl purta bhawan salt lake kolkata
Electrical Installation work and Internal Electrification works for SITC of Split AC Systemat New Special Court for Criminal Cases related to elected MPs MLs at Mayukh Bhaban Salt Lake Kolkata 91
2018_WBPWD_160746_1
WBPWD/EE/BED/89/e-IT of 2017_18
Open Tender
ELECTRICAL WORKS M/R
Item Rate
20 days
Mayukh Bhavan
Please refer Tender documents.
4 documents required · 4 mandatory
₹19,052
Yes
27 Feb 2020
5 Mar 2018
26 Mar 2018
9 Mar 2018
23 Mar 2018
9 Mar 2018
Amount
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. Make- (Phlips,(Cat no TMC 501 P 2XT-LED 22W P3242) /Crompton/Bajaj/wipro) etc. with fixing 2 no Essential LED tube.
Extra down rod for tube light fittings as to GS.(14SWG)
S&F 2'X2' LED light fittings suspended 25cm bellow the ceiling with "L" type MS clamp whose one side fixed on ceiling with suitable size 4nos. 6mm fastner & other side connection with the conduit with suitable size of bolts & nuts incl.. S&F EL conduit, "L" type (125mmX125mm) 6mm thick and 25 mm with ms clamps & connecting the length of PVC insulated cu wire and mending good damages to original finish & painting etc. by 2X24/0.20mm(1.5sqmm ). flexible copper wire of 1.10mt. Length. (Make-Phlips-Cat no-RC380B G2 LED 28S-6500 PSU OD WH/ CG/Bajaj/ wipro)
Supply& Fixing 1200 mm sweep AC celling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. (Make- Orient/Crompton/Usha)
S & F of 16” sweep Bracket fan on HW block as to GS (Make- CG-WMSD/Orient/Usha)
S/F 230V, 250 Watt Step Type Electronic Fan regulator on modular type board as per GS
S/F 14 SWG Extra down rod for supplying additional wire for down rod & paining the rod exceeding 30cm by 2X1.5 sqmm. flexible copper wire for ceiling fan.
S&F only exhaust fan after making hole in wall and making good damages and smooth cement finish & louver shutter/cowl etc. as practicable as possible and providing necy.length of PVC insutated wire and making connection for exhaust of following diameter.(Make-EPC/CG/ Havells) a)23cm(9")
Supply and Fixing only fan clamp for RC ceiling as per specification after cutting the ceiling & binding with reinforcement and mending good the damages.
S &F 250 V modular type (12 module) computer board of comprising of lowing accessories. A) 6A/16A switch & Socket- 1 Set B) 6A,------do------do----- 2 sets C) Indicator---------------- 1 set incl. Necessary interconnection by PVC insulated copper wire flushed in wall. (Brand approved by E.I.c)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy.connections with PVC Cu wire and earth continuity wire etc.
Supplying and fixing 415 V, 16-32A per way, 8 way HTPN MCB DB with SS enclosure double-door with IP-42/43 protection with Four Pole MCB as incomer and SPMCBs ('C' Curve, 10 kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for ear thing attachment Incomer-63A 4 pole MCB. Outgoing-6-32A SP MCB--24 (Make- Legrand/Havells/ABB)
Supplying and fixing double-door SPN MCB Distribution Board (2+12way) with IP-42/43 protection, on angle iron frame on wall. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Incoming: 40 A DP MCB --- 1 nos. Outgoing: 6 - 16 A SP MCB --- 12 nos. (Make- Legrand/Havells/ABB)
S/F and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.Incoming-415V,25KA,125A,FP MCB--1No 415V, 10KA, 63A T.P MCB C curve--6 nos & Other outgoing are covered by Blank Plate (Make- Legrand/Havells/ABB)
S/Laying of 4 core 50 Sq mm XLPE/PVC Al armoured cable on wall with S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting. (Make- Havells/KEI/Glostar)
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below : 4 core 50 Sq mm
Finishing of the XLPE/PVC insulated armoured cable ends by soldering with cable sockets and insulated tapes etc., including supplying sockets, soldering materials, tapes etc. and making connection to switch, BDB and BBC etc 4 core 50 Sq mm
Supply & Laying 65 mm dia G.I Protection Pipe underground strange cutting the floor with out brick protection & mending good damages without net cement & polish.
Distribution wiring in 1.1 KV single cores stranded 'FR'PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR'(Precision make) incl. necy. fittings as required. a) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC( from SPNDB to TPNDB) (Make-Finolex/Havells)
b) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC( from SPNDB to TPNDB) (Make-Finolex/Havells)
c) 3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC ( from VTPN to TPNDB) (Make-Finolex/Havells)
d) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC (power point& computer connection) (Make-Finolex/Havells)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) 2X84/0.3(6 sq mm)+1X 56/0.3(4 sq mm)
ii) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm)
iii) 2X36/0.3 (2.5 sq mm)+ 1X22/0.3 (1.5 sq mm)
iv) 3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm)
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish. {PVC Rigid Conduit 'FR' (ISI Marked) on wall/ceiling with Modular type Switch.} a) Average Run- 11 Mtr
b) Average Run- 12 Mtr
c) ---Do---Do----Do---- On board
S&F 125A MCCB with necessary accssories as required. (Make L&T, cat no-CM90996OOOO)
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: A) By TATA-Medium GI pipe
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
S&F of A.C Power unit by switch type starter module having automatic volt,amp check facilities on 4 module G.I box. (Make-OLP30)
Supply & fixing of multitune wire less call bell with 2 nos battery for each units (Make- CONA/ Anchor)
L.W.C. must be quoted manually @1% on the total quoted value else the total quoted rate shall be treated incl. LWC as per rule. N.B. Rate should be quoted inclusive of GST.
BANERJEE CONCERN
S. A. ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .