Loading…
Loading…
Tender Value
₹7.6 L
EMD Value
₹18,928
Closing Date
19 Jun 2026, 4:00 pm5d left
Assistant Engineer
OFFICE OF AEE, LIDEW ,Vamanapuram BP
Annual Plan-Vamanapuram BP 2025-26 Setting of Block Panchayath Presidents office room-Prj. No. 224/26-General Civil Work
2026_LSGD_855358_1
01/2026-27/AE/LIDEW/VMPM
Open Tender
Civil Works - Buildings
180 days
VENJARAMOODU
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,670
Yes
₹18,928
Yes
12 Jun 2026
12 Jun 2026
22 Jun 2026
12 Jun 2026
19 Jun 2026
12 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1President room renovation | ||||||
| 1.001 | OD53903/2026-2027:od102331/2023_2024 :Providing and fixing storage unit/file rack of 40 cm depth, at 60 cm height and 60cm width, using 17 mm interior grade MDF frames and racks. Inside area to have 0.7mm thick white/off white laminate. Back side to have 6 mm thick multiwood. Doors to be made of 17 mm interior grade MDF at height 210/240 cm. All exposed portion to be finished with 0.8 mm thick decorative laminate of approved make and colour. Multilocks, auto hinges to be fixed. etc as per design and size and direction of engineer in charge. NC putty to be applied neatly on all exposed edges, if any. Including all cost to finish work at site | - | sqm | - | - | BI01010001010000000000000515BI0100001114 |
| 1.002 | 15.13.1:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area 3 sq. metres and below | - | each | - | - | BI01010001010000000000000515BI0100001115 |
| 1.003 | 15.13.2:Taking out doors, windows and clerestory window shutters (steel or wood ) including stacking within 50 metres lead:Of area beyond 3 sq. metres | - | each | - | - | BI01010001010000000000000515BI0100001116 |
| 1.004 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 1 | sqm | - | - | BI01010001010000000000000515BI0100001117 |
| 1.005 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | - | cum | - | - | BI01010001010000000000000515BI0100001118 |
| 1.006 | 26.42.2:Providing and fixing of external wall system on Light gauge steel frame work with outer face cement boards as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make. A groove of 2 mm to 3mm shall be maintained and grooves shall be sealed with silicon based sealant. The board shall be fixed in a staggered pattern. Screws shall be of counter sunk rib head of 1.60mm to 4 mm thick or 8 to 10 gauge of length varying from 25 to 45 mm and. Internal face 12.5 mm thick gypsum plaster board fixed on cement board as per standard sizes fixed with self- drilling / taping screws / fasteners @ 60cm c/c of approved make, proper taping and jointing to be done using fiber mesh tape and epoxy and acrylic based jointing compound for seamless finish.(cost of frame work to be paid for separately)Outer face: Outer face having 8 mm thick cement bonded particle Board fixed on 10 mm thick cement bonded particle board. (Termite, Fire and Moisture Resistance) as per IS 14276:1995. Inner face:-12.5 mm thick gypsum plaster board conforming to IS 2095:2011 fixed on 8 mm thick cement bonded particle board (Termite, fire and moisture resistance) confirming to IS:14276:1995) | 1 | sqm | - | - | BI01010001010000000000000515BI0100001119 |
| 1.007 | 10.16.2:Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished seamless type tubes | 0.6 | kg | - | - | BI01010001010000000000000515BI0100001120 |
| 1.008 | 13.26:Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. | - | sqm | - | - | BI01010001010000000000000515BI0100001121 |
| 1.009 | 13.43.1:Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface:Water thinnable cement primer | - | sqm | - | - | BI01010001010000000000000515BI0100001122 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.41 MB
Tendernotice_2.pdf
PDF • 0.28 MB
viewsbd.pdf
Tender Documents • 1.87 MB
fot.pdf
Tender Documents • 0.33 MB
aff.pdf
Tender Documents • 0.32 MB
epayment.pdf
Tender Documents • 0.49 MB
BOQ_1445599.xls
BOQ • 0.34 MB
viewnit.pdf
Tender Documents • 0.07 MB
fee.pdf
Tender Documents • 0.47 MB
pa.pdf
Tender Documents • 0.34 MB
Download all tender documents and submit your bid