| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.3 LAccepted-AOC RH NO 06 KARMA KSHETRA HOUSING SOCIETY SECTOR 29 PRADHIKARAN RAVET POST DEHU ROAD 412 101 | NA | NA | 412101 | L1 | Accepted-AOC Being lowest, L1. | |
| 2 | L2₹50.0 L+₹1.6 L (3.40%)Rejected-Finance BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L2 | Rejected-Finance Not being lowest. | |
| 3 | L3₹53.9 L+₹5.6 L (11.5%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | L3 | Rejected-Finance Not being lowest. | |
| 4 | L4₹55.0 L+₹6.6 L (13.7%)Rejected-Finance | L4 | Rejected-Finance Not being lowest. | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Recommended due to documents verification not received. |
| Sl No | Description | Qty | Unit | V r traders L3 | AGRAWAL ASSOCIATES L2 | Shri Sai Electricals L1 | DHARMESH ENTERPRISES L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 25 KVA DG set all as directed. | 1 | Each | 5,999 ₹5,999 | 500 ₹500 Lowest | 4,500 ₹4,500 | 1,000 ₹1,000 |
| 2.00 | Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 30 KVA DG set all as directed. | 3 | Each | 5,999 ₹17,997 | 500 ₹1,500 Lowest | 7,500 ₹22,500 | 1,000 ₹3,000 |
| 3.00 | Taking down the existing silencersystem, modification the cannopy to installed retrofit emission control device of capacity 62.5 KVA DG set all as directed. | 7 | Each | 9,999 ₹69,993 | 500 ₹3,500 Lowest | 8,000 ₹56,000 | 1,500 ₹10,500 |
| 4.00 | Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 140 KVA DG set all as directed. | 1 | Each | 9,999 ₹9,999 | 500 ₹500 Lowest | 9,000 ₹9,000 | 2,000 ₹2,000 |
| 5.00 | Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 160 KVA DG set all as directed. | 1 | Each | 9,999 ₹9,999 | 500 ₹500 Lowest | 10,000 ₹10,000 | 2,000 ₹2,000 |
| 6.00 | Taking down the existing silencersystem, modification the cannopy to installed retrofit emission control device of capacity 150 BHP DG Pump set all as directed. | 1 | Each | 9,999 ₹9,999 | 500 ₹500 Lowest | 11,000 ₹11,000 | 2,000 ₹2,000 |
| 7.00 | Taking down the existing silencerr system, modification the cannopy to installed retrofit emission control device of capacity 165 BHP DG Pump set all as directed. | 1 | Each | 9,999 ₹9,999 | 500 ₹500 Lowest | 12,500 ₹12,500 | 2,000 ₹2,000 |
| 8.00 | Supply Installation testing and commissioning Of retro fit emission control device for 25 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
Note:-(i) Device should be Type Approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets should be as per CPCB instructions and the same has to be obtained from the following CPCB Prescribed labs.
(ii)Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type : Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5)
(iii) Carbon Monoxide, Hydrocarbon reduction efficiency Retrofit device is to be installed in place of existing silencer. No soot is to be collected in the retrofit device. The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap.A Manual Valve will be given after the first stage(Oxidation Stage) and before the second stage (passive Regeneration trap)of the DOFF, Noise attenuation is with in the permissible limits ,Equipped with mechanical pressure relief system,capturing chamber made of resistance process treated Mild steel etc.as reqd.
(iv). The RECD device provided by the seller should be equipped with a remote Data Monitoring system certified by ICAT/ ARAI providing essential information recorded at every 15 minutes, including but not limited to:
a. Energy consumption
b. Running hours
c. Warnings related to ECD diagnosis for the following conditions:
1. Complete loss of particulate capture function
2. Removal of the ECD system
3. Failure of the ECD system
4. Detection of exhaust bypass, temporary or permanent, as part of field/operator tampering
Min Particular Matter Reduction 85%,Min Carbon Monoxide Reduction 90%,Min Hydrocarbon Reduction 90% | 1 | Each | 1,89,999 ₹1,89,999 | 2,50,000 ₹2,50,000 | 1,95,000 ₹1,95,000 | 1,50,000 ₹1,50,000 Lowest |
| 9.00Note:-2 TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit.and Drawing Should be approved by Engineer In ChargeGeneral Technical Requirements (GTR) / Commissioning :- a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. c )Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motorable way. f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. g) Exhaust piping, extra civil work, distribution board shall be provided by the seller | |||||||
| 10.00Note:3-Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device. b) Construction of suitable earthing station (If applicable) and necessary connections shall be done by the seller. Warranty/Service - 12 months of preventive maintenance visits offered in a year during warranty period : 2 visits. c) The Device to be minimum 10-12 year life in place of from date of commissioning, The guarantee certificate to be submitted to Engr-in-charge after commissioning the equiptments. (d) DELIVERABLES, TIME SCHEDULE Submission of approach of work/ methodology, Drawings and the details of team as per the scope of work :- 30 days. Delivery Of Device :- 60 days. Installation, Testing Commissioning at site of retrofit emission control device on existing DG sets :- 90 days (e) Factory visit of device by Engineer in charge for approval is required before purchasing and further installation of retro fitting which is to be catered by contractor (f) OEM have to provide mandatory. COP (Conformity of Production) certificate from ARAI / ICAT. (g) OEM authorisation letter for participating in the tender. | |||||||
Tender Value
₹65 L
EMD Value
₹1.2 L
Closing Date
17 Jun 2025, 6:00 pmClosed
GE dehu road Pune
GE dehu road Pune
MAINTENANCE AND UPGRADATION OF STAND BY DG SETS UNDER AGE E/M OF GE DEHU ROAD
2025_MES_702781_3
8941
Open Tender
Civil Works
Item Wise
180 days
GE dehu road
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
GE dehu road
₹1.2 L
23 Aug 2025
27 May 2025
19 Jun 2025
27 May 2025
17 Jun 2025
3 Jun 2025
Amount
Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 25 KVA DG set all as directed.
Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 30 KVA DG set all as directed.
Taking down the existing silencersystem, modification the cannopy to installed retrofit emission control device of capacity 62.5 KVA DG set all as directed.
Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 140 KVA DG set all as directed.
Taking down the existing silencer system, modification the cannopy to installed retrofit emission control device of capacity 160 KVA DG set all as directed.
Taking down the existing silencersystem, modification the cannopy to installed retrofit emission control device of capacity 150 BHP DG Pump set all as directed.
Taking down the existing silencerr system, modification the cannopy to installed retrofit emission control device of capacity 165 BHP DG Pump set all as directed.
Supply Installation testing and commissioning Of retro fit emission control device for 25 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets. Note:-(i) Device should be Type Approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets should be as per CPCB instructions and the same has to be obtained from the following CPCB Prescribed labs. (ii)Application :- Reduce particulate matter (PM 2.5), Carbon Monoxide and Hydrocarbons emitted from Diesel Engine Technology/Type : Wet Scrubbing, Diesel Oxides Catalyst Guaranteed specified Particulate matter (PM 2.5) Carbon Monoxide, Hydrocarbon reduction efficiency (Min) Guaranteed specified Particulate matter (PM 2.5) (iii) Carbon Monoxide, Hydrocarbon reduction efficiency Retrofit device is to be installed in place of existing silencer. No soot is to be collected in the retrofit device. The device including enclosure should include an Oxidation chamber and Passive Regeneration Trap.A Manual Valve will be given after the first stage(Oxidation Stage) and before the second stage (passive Regeneration trap)of the DOFF, Noise attenuation is with in the permissible limits ,Equipped with mechanical pressure relief system,capturing chamber made of resistance process treated Mild steel etc.as reqd. (iv). The RECD device provided by the seller should be equipped with a remote Data Monitoring system certified by ICAT/ ARAI providing essential information recorded at every 15 minutes, including but not limited to: a. Energy consumption b. Running hours c. Warnings related to ECD diagnosis for the following conditions: 1. Complete loss of particulate capture function 2. Removal of the ECD system 3. Failure of the ECD system 4. Detection of exhaust bypass, temporary or permanent, as part of field/operator tampering Min Particular Matter Reduction 85%,Min Carbon Monoxide Reduction 90%,Min Hydrocarbon Reduction 90%
Note:-2 TEST REPORTS Certification :- Device should be ‘Type Approved’ as per the System and Procedure of Central Pollution Control Board for Emission Compliance Testing of Retro-fit Emission Control Devices (RECD) For Diesel Power Generating Set Engines, Dated 01/02/2022, wide Pollution Control Series PCLS/12/2021-22 Adhering to this, RECD to be ‘Type Tested’ for an equivalent kVA family as per the System and Procedure from any one of the four Central Pollution Control Board, Govt, of India, recognized/approved test agencies/laboratories as given below: (a) Automotive Research Association of India (ARAI, Pune) (b) International Centre for Automotive Testing (ICAT, Manesar) (c) Indian Institute of Petroleum (IIP, Dehradun) (d) Vehicle Research Development Establishment (VRDE, Ahmednagar): Back Pressure due to the Emission Control retrofit device :- Maximum back pressure exerted by the Emission Control retrofit device at max prescribed load by DG OEM(as per the capacity of the DG set) should be under limit and display panel to be provided for Back pressure and exhaust temperature limit.and Drawing Should be approved by Engineer In ChargeGeneral Technical Requirements (GTR) / Commissioning :- a) Emission Control retrofit device shall be complete with safety precautions to ensure no damage should be done to the DG set operations under any circumstances. The Emission Control retrofit device should be closely coupled with the DG exhaust to ensure 100% of the exhaust passes through the Emission Control retrofit device. b) Anti-Vibration mountings shall be provided for complete Emission Control retrofit device in case of flexible coupling with the diesel generator exhaust. c )Emission Control retrofit device should have protection against under voltage, over voltage, under frequency, over frequency, low battery voltage, over current, earth-fault, short circuit, phase sequence change etc. d) The Emission Control retrofit device shall be with corrosion resistive and HR paint. e) Unloading and placement of the Emission Control retrofit device at the time of delivery is in the scope of buyer. The consignee shall ensure that the site is located along a motorable way. f) The seller shall provide the trial run (Testing) of Emission Control retrofit device. The seller shall conduct trial run of the Emission Control retrofit device with the available electrical load at site. The trial run shall be for TWO hours. The electrical loading shall not be more than the rated capacity of the DG set. g) Exhaust piping, extra civil work, distribution board shall be provided by the seller
Note:3-Scope of Installation :- a) Installation of Emission Control Retrofit Device when offered by the vendor is inclusive in the scope of supply and shall be done by the seller. The installation work of Emission Control Retrofit Device. b) Construction of suitable earthing station (If applicable) and necessary connections shall be done by the seller. Warranty/Service - 12 months of preventive maintenance visits offered in a year during warranty period : 2 visits. c) The Device to be minimum 10-12 year life in place of from date of commissioning, The guarantee certificate to be submitted to Engr-in-charge after commissioning the equiptments. (d) DELIVERABLES, TIME SCHEDULE Submission of approach of work/ methodology, Drawings and the details of team as per the scope of work :- 30 days. Delivery Of Device :- 60 days. Installation, Testing Commissioning at site of retrofit emission control device on existing DG sets :- 90 days (e) Factory visit of device by Engineer in charge for approval is required before purchasing and further installation of retro fitting which is to be catered by contractor (f) OEM have to provide mandatory. COP (Conformity of Production) certificate from ARAI / ICAT. (g) OEM authorisation letter for participating in the tender.
Note : Supply, Installation, Testing & Commissioning of Type approved RECDs( Retrofit Emission Control Devices) to control air pollution from existing DG sets as per the latest guidelines of CPCB/CAQM etc. Technical specifications, RECD features & Essential Terms & Condition strictly as per the below mentioned details. TECHNICAL SPECIFICATIONS S. No. Description Desired Features/Spects 1. Approvals & Efficiencies 1.1 Approval CPCB/CAQM designated agency- ARAI or ICAT/Other 1.2 Efficiency PM removal >80% 1.3 Efficiency-CO/HC removal >70% 2. Constructions Materials 2.1 MOC of RECD 409 SS/Heat resistant Ferrie SS/Corrosion Resistance 3. Compensator Yes 3.1 MOC 304SS 4. Clamp Mechanism Roto seal/Engineered clamp mechanism for quick service/should be temper proof 5. OBD Onboard Diagnostic panel with temperature /pressure sensors. 5.1 RECD Monitoring Online Monitoring System for 24x7 monitoring of RECD health 6. Size/Weight of RECD Should be of compact size/light weight /can be installed over DG set 7. Technologe Type DOC (Diesel Oxidation Catalyst) +DPF (Diesel Particulate filter) with automatic regeneration 8. Hazardous waste No hazardous waste 9. Power consumption NO/Zero
General Conditions DG emission having following compliances/specifications/General features/Safety features: - RECD should be free from hazardous waste generation. Device should be energy efficient i.e. No power consumption & with no waste Generator (carbon collection) & can be quickly installed. Device should have automatic regeneration mechanism for ensuring trouble free operation and minimal human intervention. Type Approval should be from designated agencies (by CPCB) only and strictly according to systems & procedures of CPCB laid down in CPCB guidelines.
Special Conditions As this facility is critical national asset, safety and speed is utmost important, RECD should be equipped with 24x7 online health monitoring system for proactive indication/service. Also, RECD should be equipped with engineered clamp mechanism for quick opening & closing of RECD at the time of emergency to ensure minimum down time. RECD should be equipped with compensator for safety of RECD/long life. Bidder should have type approved RECDs for all capacities of DG sets-Entire range-40KVA-1000KVA. Confirm and submit all the certifications. Bidder should have completed at least one successful installation of each category of DG sets i.e. up to 250 KVA. Bidder have to ensure the quick service and for this they have to provide documentary evidence of their registered workshop/service station. Bidder should have capability to install Online emission monitoring systems comprising Emission Analyzer / necessary Hardware & Software for data logging /Data transmission & Submission facility (to PCB). Documentary evidence to be submitted Bidder should have capability & experience of at least 12 months of installation of RECDs/ online health monitoring of RECD. The device should be expandable and futuristic to cater to any additional systems and components may be suggested by CPCB (as per CPCB guidelines). Capability to certify the work by Certified Energy Auditor/Manager. This is to ascertain that no adverse impact will be on entire energy /power generation capacity of the facility after installation of RECDs. Following documents should be submitted while filling technical bid. Type approval certificates for entire range i.e. 50KVA-1000KVA -Exp: - Similar work experience during last three years is mandatory. Similar work means supply, Installation, Testing & Commissioning of RECD in existing DG Sets. -Exp: - Documentary evidence of SITC of online health monitoring system. Own registered work shop/service station -List of team with qualifications. Availability of at least one certified energy auditor/manager ( certified by BEE ( Bureau of energy efficiency) for certifying the entire work
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 30 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 62.5 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 140 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 160 kVA desiel generator to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 150BHP desiel generator pump set to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
All as per item before but Supply Installation testing and commissioning Of retro fit emission control device for 165 BHP desiel generator pump set to match the existing DG set complet all as directed.The retro fit emission control device should have approved (CPCB-I / CPCB-II whichever is applicable to particular DG Set) for family of DG sets.
AGRAWAL ASSOCIATES (BID ID -3318713)
V r traders (BID ID -3316410)
DHARMESH ENTERPRISES (BID ID -3318654)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .