| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAdmitted-Finance 108 3 CHANDAR NAGAR DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹2.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.7 Cr+₹19.5 L (7.95%)Admitted-Finance 231 SATYA VIHAR MADAN CONTRACTORS AND COMO VIJAY PARK DEHRADUN DEHRADUN UTTARAKHAND 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹2.7 Cr+₹19.5 L (7.95%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Madan Contractors & Co. L2 | MITTAL MACHINES PVT LTD L1 |
|---|---|---|---|---|---|
| 1.00 | 145 kV Circuit Breaker 1600A | 1 | Set | 17,68,000 ₹17,68,000 | 14,00,000 ₹14,00,000 Lowest |
| 2.00 | 145 kV CT 60/1-1-1-1-1A | 4 | No | 5,59,800 ₹22,39,200 | 4,18,000 ₹16,72,000 Lowest |
| 3.00 | 145 kV Isolator 1600A , Centre Break type SDF along with hot dip galvanized steel base frame with two rotary pedestals, insulators,current carrying conductors (current path) and driving mechanisms | 1 | Set | 2,80,000 ₹2,80,000 Lowest | 2,87,742 ₹2,87,742 |
| 4.00 | 145 kV Isolator Tendam Type | 1 | Set | 4,10,640 ₹4,10,640 | 3,22,000 ₹3,22,000 Lowest |
| 5.00 | 120 kV Lightning Arrester,Line discharge class-3 | 3 | No | 92,300 ₹2,76,900 Lowest | 95,500 ₹2,86,500 |
| 6.00 | 6.6 kV Circuit Breaker Panel Board with 1 Income + 2 Outgoing | 1 | No | 29,74,800 ₹29,74,800 | 26,80,000 ₹26,80,000 Lowest |
| 7.00 | 6.6 kV LA ,type -Silicon polymeric | 3 | No | 12,500 ₹37,500 Lowest | 13,250 ₹39,750 |
| 8.00 | Control cum Relay panel for 132 kV transformer. | 1 | No | 19,00,000 ₹19,00,000 | 15,00,000 ₹15,00,000 Lowest |
| 9.00 | Supply Of 11 kV VCB ICOG Panel. | 1 | No | 6,20,000 ₹6,20,000 Lowest | 6,35,000 ₹6,35,000 |
| 10.00 | Supply of 6.6 kV/ 415 V Transformer 500KVA | 1 | No | 11,57,500 ₹11,57,500 Lowest | 12,25,000 ₹12,25,000 |
Tender Value
₹2.5 Cr
EMD Value
₹4.9 L
Closing Date
28 May 2025, 3:00 pmClosed
Executive Engineer (M G) Kulhal Power Station, Kul
Executive Engineer (M G) Kulhal Power Station, Kulhal
Extension of Bay at 132kV Switchyard at Kulhal Power station
2025_UJVN_83590_1
01/UJVNL/EE (M G)/KPS/2025-26
Open Tender
Electrical Works
Item Rate
210 days
Kulhal
Please refer Tender documents.
3 documents required · 3 mandatory
₹11,800
PNB, A/c No 1072002105502148
₹4.9 L
18 Jun 2025
6 May 2025
3 Jun 2025
6 May 2025
28 May 2025
13 May 2025
Amount
145 kV Circuit Breaker 1600A
145 kV CT 60/1-1-1-1-1A
145 kV Isolator 1600A , Centre Break type SDF along with hot dip galvanized steel base frame with two rotary pedestals, insulators,current carrying conductors (current path) and driving mechanisms
145 kV Isolator Tendam Type
120 kV Lightning Arrester,Line discharge class-3
6.6 kV Circuit Breaker Panel Board with 1 Income + 2 Outgoing
6.6 kV LA ,type -Silicon polymeric
Control cum Relay panel for 132 kV transformer.
Supply Of 11 kV VCB ICOG Panel.
Supply of 6.6 kV/ 415 V Transformer 500KVA
Supply of 6.6 kV/ 11 kV Transformer 500KVA
Latis type GI Structure for 145 kV Current Transformer
Latis type GI Stricture for 132KV Tendam Isolator
Latis type GI Structure for 11kv LA
Latis type GI Gantry Tower
Latis type GI Gantry BEAM
ACSR Panther conductor
Disc Insulator string for 145 kV suspension type (Silicon Type) 8*9 insulator
Clamp & Connector for 145 kV Equipment
Hardware For Control wiring like Lug Ferule, Cable Tie, Gland etc.
CT Junction Box
11KV Cable End Termination Kit
10C X 2.5 Sq mm ,1.1 kV ,copper armoured cable
4C X 2.5 Sq mm ,1.1 kV, copper armoured cable
2C X 2.5 Sq mm ,1.1 kV , copper armoured cable
11KV (UE)HT XLPE CABLE 3C X 300SQ MM
3.5 Core 400 sqmm XLPE Aluminium Cable 1.1 kv grade
Making of foundation for 145 kV Circuit Breaker
Making of foundation for 145 kV Circuit CT
Making of foundation for 145 kV bus Isolator
Making of foundation for 145 kV Tandam Isolator
Making of foundation for 145 kV gantory tower
Making of Foundation for 132 kV/6.6 kV Transformer
Making of Foundation for 6.6kV/0.415kV Transformer
Making of Foundation for 6.6kV/11 kV Transformer
Designing & Making of Oil Collection Trench/Gallery around 132 KV/6.6 kV Transformer
Designing & Making of Cable Trench in brick Work with trench cover and cable tray.
Designing & Laying Rail for traveling the Gen Transformer as per site requirement.
Shifting and modifying the fabricated stair and outside wire mesh boundary from the existing area as a site requirement
Demolishing & Shifting the 02 Nos compressor with all accessories like pipe line Air recevier tank with panel etc from exist position to at generator floor inside Power house
Shifting the 12.5 MVA transformer from erection bay to New Foundation
Demolishing the existing building for 132/6.6 kV Generator transformer, proper leveling of area for transformer plinth.
Fabrication,installation & Testing of Complete package of Galvanised Steel Structures along with required G. I. Bolts with Nuts (ISI Marked), Spring Washers, etc. for 132 kV Transformer Bay as well as equipment structres Viz. CB, CT, LA, BUS Isolators.
ETC of 145 kV Circuit Breaker
ETC of 145 kV CT
ETC of 120 kV LA
ETC of 145 kV Bus Isolator
ETC of 145 kV Tandom Isolator
ETC of 11KV LA
ETC of 11KV IC-OG Panel
ETC of 132KV / 6.6 KV 12.5 MVA Transformer with panel and relay
ETC of 6.6KV / 415V 500KVA Transformer with panel and relay
ETC of 6.6KV / 11 kV 500KVA Transformer with panel and relay
Laying and Termination of Control Cable
Laying and termination of 11KV HT XLPE Cable
Earthing of All Equipment 34 Nos earthing pit and including earth mat with necessary materials
Madan Contractors & Co. (BID ID -384159)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.38 MB
Tender_01.pdf
Tender Documents • 1.84 MB
BOQ_99474.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .