Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical ALL RELEVANT DOCUMENTS UPLOADED AS PER SBD |
| 2 | Accepted-Technical | Accepted-Technical ALL RELEVANT DOCUMENTS UPLOADED AS PER SBD |
| 3 | Accepted-Technical | Accepted-Technical ALL RELEVANT DOCUMENTS UPLOADED AS PER SBD |
Tender Value
Refer Docs
EMD Value
₹10,440
Closing Date
5 Mar 2026, 4:00 pmClosed
Executive Engineer ED-Rajouri
Executive Engineer ED-Rajouri
EDR/97 of 2025-26 dated 25-02-2026
2026_PDD_304515_1
EDR/97 OF 2025-26 DATED 25-02-2026
Open Tender
Electrical Works
Turn-key
20 days
Rajouri
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
Executive Engineer ED-Rajouri
₹10,440
6 Mar 2026
25 Feb 2026
6 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Select, At Par, Excess (+), Less (-) IOCL
Tender Inviting Authority: EXECUTIVE ENGINEER, ELECTRIC DIVISION, JPDCL, RAJOURI
Name of Work: 1.Creation of 25KVA S/Stn alongwith HT/LT network at Mohalla Mehmood Saralla W No 3 Mehari Gujjaran Rajouri on Mehari Feeder Under TSP Grants 2. Creation of 25KVA S/Stn alongwith HT/LT network at Massi Mohalla W No 3 Village Sawani on Chatyari feeder Under TSP Grants (All the items should be as per latest specifications and drawing adopted/Approved by Department)
e-NIT No: EDR/ 97 of 2025-26 Dated 25-02-2026
Name of the Bidder/ Bidding Firm / Company :
Sl. No. Item Description * Bidders are requested to quote the rates for all items which must be inclusive of Supply, Erection, Testing and commissioning of all items including Taxes, Labour charges, Overhead Charges etc. ** Before quoting the rates bidders are requested to visit the site *** Material should be in accordance to latest IS and IEC Standards Item Code / Make Quantity Units Estimated Rate in Rs. P Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category
2 1.Creation of 25KVA S/Stn alongwith HT/LT network at Mohalla Mehmood Saralla W No 3 Mehari Gujjaran Rajouri on Mehari Feeder Under TSP Grants.
3 SITC OF HT Line
4 S.T Pole 8 mtrs long (410-SP15) 1 No Excess(+) Full Conversion INR
5 Galvanisied V cross-arm with top bracket including clamp item5 30 KG Excess(+) Full Conversion INR
6 30 mm2 ACSR Weasel Conductor item6 0.2 Kms Excess(+) Full Conversion INR
7 11 kv Pin insulators with pins (10KN) item7 6 No Excess(+) Full Conversion INR
8 11 kv Disc insulators with fittings (45 KN) item8 No Excess(+) Full Conversion INR
9 Al. Painting item9 1 ltrs. Excess(+) Full Conversion INR
10 Red Oxide item10 1 ltrs. Excess(+) Full Conversion INR
11 Galvansied Nuts and Bolts of sorts item11 1 Kg Excess(+) Full Conversion INR
12 SITC OF SUB STATION
13 25KVA Transformer Level II , 11/0.433KV,3-Phase Distribution Transformer with Bimetallic Terminal Connectors ,Aluminium Wound and with LV Cable Box having detachable Aluminium Gland plate. No Excess(+) Full Conversion INR
14 S.T Pole 8 mtrs long (410-SP15) item14 No Excess(+) Full Conversion INR
15 Surge Arrester Station Type 9KV, 10 kA (Polymer Type) item15 Set Excess(+) Full Conversion INR
16 11 KV Horn Gap Set, 3 Phase, 200 Amp item16 Set Excess(+) Full Conversion INR
17 Channel/Flate/Angle in shape of fabricated X-arms, Top bracket, Angle braces, clamps etc. item17 Kg Excess(+) Full Conversion INR
18 PVC insulated stranded conductor FRLS type 1.1kv Grade Cable 120mm sq with Thimbles item18 Mtr Excess(+) Full Conversion INR
19 Earthing of Sub-station ,excavation of earth pit of dia 650mm and depth 3000mm,installation of earthing pipe of 40mm nominal bore and 4mm wall thickness and length 2.5 mtr.long as per IS 1239.GI strip for neutrl earthing of size 25 mm*3 mm for connection of transformer body ,G.O set and lightening arrestor as per IS 2629/85,GI nuts and bolts ,refilled with earth enhancement materials and earth chamber made of brick masonary with RCC slab cover. (Specification as per cost data) item19 No Excess(+) Full Conversion INR
20 11 kv Pin insulators with pins (10KN) item20 No Excess(+) Full Conversion INR
21 11 kv Disc insulators with fittings (45 KN) item21 No Excess(+) Full Conversion INR
22 Nuts and Bolts of sorts item22 Kg Excess(+) Full Conversion INR
23 Al. Painting item23 ltrs. Excess(+) Full Conversion INR
24 Red Oxide item24 ltrs. Excess(+) Full Conversion INR
25 Sundry Items/POL item25 LS Excess(+) Full Conversion INR
26 SITC OF LT Line
27 S.T Pole 8 mtrs long (410-SP15) No Excess(+) Full Conversion INR
28 30 mm2 ACSR Weasel Conductor item28 0.1 Kms Excess(+) Full Conversion INR
29 Shakle Insulator (16KN) item29 Nos Excess(+) Full Conversion INR
30 Mukky Clamps item30 Nos. Excess(+) Full Conversion INR
31 Red Oxide item31 ltrs. Excess(+) Full Conversion INR
32 Al. Painting item32 ltrs. Excess(+) Full Conversion INR
33 Danger Plate item33 No. Excess(+) Full Conversion INR
34 Nuts and Bolts of sorts item34 Kgs Excess(+) Full Conversion INR
35 2.Creation of 25KVA S/Stn alongwith HT/LT network at Massi Mohalla W No 3 Village Sawani on Chatyari feeder Under TSP Grants
36 SITC OF HT Line
37 S.T Pole 8 mtrs long (410-SP15) 8 No Excess(+) Full Conversion INR
38 Galvanisied V cross-arm with top bracket including clamp item38 200 KG Excess(+) Full Conversion INR
39 30 mm2 ACSR Weasel Conductor item39 1.4 Kms Excess(+) Full Conversion INR
40 11 kv Pin insulators with pins (10KN) item40 24 No Excess(+) Full Conversion INR
41 11 kv Disc insulators with fittings (45 KN) item41 No Excess(+) Full Conversion INR
42 GI Stay sets complete with 50*8mm stay clamp ,guy insulator(2 nos.),anchor plate(200*200*6mm),nut-bolts,turn -buckles(2 nos.),1.8m long,16mm diameter solid GS stay rod and 7/3.15 mm dia GI stranded wire complete. item42 No Excess(+) Full Conversion INR
43 Al. Painting item43 8 ltrs. Excess(+) Full Conversion INR
44 Red Oxide item44 8 ltrs. Excess(+) Full Conversion INR
45 Anti Climbing Device with clamps item45 8 No. Excess(+) Full Conversion INR
46 Danger Plates with Clamps item46 8 No Excess(+) Full Conversion INR
47 Galvansied Nuts and Bolts of sorts item47 8 Kg Excess(+) Full Conversion INR
49 Providing of computriised single diagram of the complete work depicting all vital items including landmark (size of sheet 24X24 inch) item1.55 no Excess(+) Full Conversion INR
50 Providing of geo tagged coloured photographs of all the vital items of the work including name plate of Transformer(size of photograph 4X6 inch) item1.56 no Excess(+) Full Conversion INR
Total in Figures
Quoted Rate in Figures Select
Please Enable Macros to View BoQ information
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.49 MB
SBD.pdf
Tender Documents • 1.61 MB
BOQ_989143.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .