Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹17.9 L+₹32,404 (1.84%)Rejected-Finance HARI OM BHAWAN CIRCULAR ROAD UPPER KAITHU SHIMLA | L2 | Rejected-Finance Being L2 |
Tender Value
₹17.1 L
EMD Value
₹36,000
Closing Date
17 Jan 2022, 5:00 pmClosed
XEN Elect Division No II
XEN Elect Division No II HPPWD Shimla-2
Providing addressable fire alarm system
2021_PWD_55203_1
ED.II.GA.Tender/21-22-7571-72 dated 28.12.2021
Open Tender
Electrical Works
Item Rate
365 days
Kalpa District Kinnaur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
EE Electrical Division No II
₹36,000
22 Apr 2022
5 Jan 2022
18 Jan 2022
5 Jan 2022
17 Jan 2022
5 Jan 2022
Amount
Addressable Fire Alarm System
Supply Installation and Commissioning of UL864 Listed and FM approved, 10th edition 32 bit 2 Loops Analog addressable Fire Alarm system , having the total panel capacity of 125 devices (detector or device any combination) in each loop. The panel shall have a backlit, 2”─x─ 4.3/4” backlit LCD screen and the four-way navigation push button at the top of the FACP. The panel shall have the capacity of storing upto 5000 events. The panel shall have Multiple levels of password protection, Automatic environmentalbe compensation for smoke detectors, Degrade-mode operation, polarity-insensitive detection circuits, Supports single-person Walk Test, Connectivity to a leased-line / city-tie module, The Panel shall disconnect backup battery on the addressable FACP when its voltage drops below 19VDC. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries upto 33 AH. The panel shall have 240 V AC power supply, 24 V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm complete as per specification. The Panel shall have the capacity of connecting additional 15 panels or Network terminals, with redundancy in the network. The panel shall have the capacity of connecting maximum 8 Remote terminals or 8 remote displays. The panel shall be approved by UL 864 10th Edition Listed, ULC, FM, CSFM & NYC Fire Department. complete the work upto the entire satisfaction of Engineer In Charge.Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL Listed and FM approved repeater Panel The panel shall be able to give location of all fire and fault and Isolation conditions of addressable units of main Fire Alarm panel via the address codes and also having remote-system-control capabilities. The panel shall have a 160 characters backlit LCD screen. Panel will show all details of above panels, complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL and FM approved Intelligent Addressable Multicriteria Smoke detector having responsiveness of photoelectric, thermal (Rate- of-Rise and Fixed), Built-in isolation (inbuilt fault isolator in detector), ionization technology and false alarm resistance along with standard base. The detector shall be Polarity insensitive, dust- resistant photoelectric chamber, Automatic environment compensation, field programmable as rate-of- rise or fixed temperature. The detector shall have Tri-color detector-status light-emitting diode (LED) with 360° view. The detector shall be approved by UL, ULC, FM, CSFM & NYC Fire Department. complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL listed and FM approved Intelligent Addressable Heat detector having responsiveness of thermal (Rate-of-Rise and Fixed), Built- in isolation, ionization technology and false alarm resistance along with standard base. The detector shall be Polarity insensitive, Automatic environment compensation, field programmable as rate-of- rise or fixed temperature. The detector shall have Tri-color detector-status light-emitting diode (LED) with 360° view. The detector shall be approved by UL, ULC, FM, CSFM & NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL listed and FM approved single action Manual Pull Station. MCP Shall be Built-in isolation, Polarity insensitive, shock and vibration resistant, inbuilt isolator. MCP shall be approved by UL, ULC, FM, CSFM & NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL listed and FM approved Intelligent addressable Output with one input module with Built-in isolation having facility to activate sounders, AHU Trippings etc. Module Shall be Polarity insensitive, inbuilt isolator approved by UL, ULC, FM, CSFM & NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply Installation and Commissioning of UL listed and FM approved Intelligent addressable one input module having facility to integrate water flow switch etc. Module Shall be Polarity insensitive, inbuilt isolator approved by UL, ULC, FM, CSFM & NYC Fire Department complete the work upto the entire satisfaction of Engineer In Charge. Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3000
Supply of UL listed and FM approved Line Isolator for isolating the section of circuit incase of short in the addressable Loop wiring Make: Siemens Cerberus / Bosch / Schneider Electric (ESMI) / Honeywell XLS3001
Supply Installation and Commissioning of 1 KVA UPS on line with 30 min backup. Make: Uniline/ APC/ Amerson
Supply, Installation, Testing and commissioning of IEC 60849 Approved Glow Type EXIT/Stair /Emergency Exit Sign Board as finalized by Engineer In Charge, on both side showing marking (running man, Arrow and Exit) and hanged with the ceiling with chain and fastener complete the work upto the entire satisfaction of Engineer In Charge. Make: PES/HEINRICH/OMEX/COOPER
Supply Installation and Commissioning of 480 W Booster Amplifier for RMS power out put 70V/ 100V and 8 OHM out put 100 V input for slave operation on 100 volts speaker lines also having temperature control in built fan for high reliability with sensitivity/ level control complete as required with Digital interface to central network controller with following features complete the work upto the entire satisfaction of Engineer In Charge. Make: BOSCh /ASL/BOSE/JBL
Supply Installation and Commissioning of 6 Watt Ceiling / Wall mounted speaker complete the work upto the entire satisfaction of Engineer In Charge. Make: BOSCh /ASL/BOSE/JBL
Supply Installation and Commissioning of 19" Presidential equipment rack of required size made out of CRCA sheet steel duly powder quoted & provided with PVC channel to house all the control equipments, amplifiers with wiring & switches complete in all respect complete the work upto the entire satisfaction of Engineer In Charge. Make: BOSCH /ASL/BOSE/JBL
Supply Installation and Commissioning of LPCB Certified 2c x 1.5 sq.mm fire survival Circuit Integrity (CI) armoured cable, 600/1000 volts with class-2 Copper conductor having halogen free ceramified silicon insulation as per BS EN 50363 and low smoke zero halogen (LSZH) inner & outer sheath. Should comply to EN 61034-2 & EN 60754-1. The cable should meet fire performance circuit integrity test as per BS EN 50200 & BS 6387 CWZ (950 Deg. C for 3 hrs).” Outer sheath in RED complete the work upto the entire satisfaction of Engineer In Charge. Make: Comrack/ DLink
Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required:- 25mm Dia
KHARBANDA ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .