Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance CHARUVILA PUTHEN VEEDU KOTTUKAL NELLIMOODU P O TRIVANDRUM 695524 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695524 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Jun 2024, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ENGINEER (PROJECTS)
KEL MAMALA KOCHI
DTPC THRISSUR- STATE TOURISM DEPT.-MAINTENANCE WORKS AT SNEHATHEERAM BEACH PARK (ELECTRICAL AND CIVIL)
2024_KEL_677099_1
KRO/BDC/1678/2024
Open Tender
Electrical and Maintenance Works
Item Rate
150 days
KEL MAMALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,950
₹50,000
Yes
2 Jul 2024
21 Jun 2024
1 Jul 2024
21 Jun 2024
28 Jun 2024
21 Jun 2024
21 Jun 2024 - 28 Jun 2024
Amount
Electrification Works
od20953/2024_2025 : Supply, installation, testing and commissioning of Floor Mounting Type High Quality Glass Fibre Reinforced Polycarbonate Insulated Outdoor Main Feeder Pillar Panel with Canopy having Metering, IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self extinguishing with glow wire test at 960 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. The Panel shall be in accordance with IEC 61439-1 and 2 and the material shall conform to RoHS directive 2002/95/EC, UV resistant according to IEC 61439-1. The Polycarbonate Panel shall also have TYPE TESTED Report (in accordance with ASTA certification by CPRI) in accordance with IEC 60439-1 and the CPRI report shall have mentioned the tests of Temperature Rise, Dielectric Properties, Short circuit withstand current - Rated peak and short time withstand current and Rated Conditional Short Circuit Current, Degree of Protection, Clearance and Creepage Distance, Mechanical Operation, Effectiveness of Protective Circuits performed and passed out satisfactorily. The manufacturer / OEM of the Polycarbonate Enclosure and Panel board shall be the same and the Routine test certificate shall be submitted. All mentioned type test certificate of the Panel shall be for Polycarbonate and shall also comply with other necessary specifications as required for outdoor panels. For all MCCBs Ics shall be 100% Icu. The panel shall conform to the Electrical Inspectorate standards and it shall only be manufactured after getting approval from the Electrical Inspectorate, Engineer-in-Charge and the Consultant.<br>BUSBAR<br>1 Runs of 20 x 10mm Copper for each Phase 1 Runs of 12 x 10mm Copper for Neutral<br>1 Runs of 12 x 10mm Copper for Earth EB INCOMER SIDE WITH METERING<br>4 Nos - Provision for fixing Resin Cast CTs<br>1 Nos - Provision for fixing CT Operated Three Phase Energy Meter<br>3 Nos - 200A Bakelite / Open Type Fuse Units with HRC Fuse of suitable rating 1 Nos - 200A Neutral Link<br>There shall be KSEBL Sealing Provision of CT Compartment and Metering Compartment<br>1 Set - RYB Indication Lamps with Control MCBs<br>1 Nos - 200A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM, Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs<br>3 Nos - 200/5A 10VA CL:1 Resin Cast CT<br>1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF with Control MCBs<br>DG INCOMER SIDE<br>1 Set - RYB Indication Lamps with Control MCBs 1 Nos - 125A 4P Switch Disconnector<br>3 Nos - 125/5A 10VA CL:1 Resin Cast CT<br>1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF with Control MCBs MECHANICAL INTERLOCK<br>Castle Key Interlock - 2 Lock with one Key so as to ensure either one of the EB or DG Supply will be working at a time<br>SURGE PROTECTION DEVICE<br>2 Nos - 4 Module DIN Rail Mounting Type 1 + Type 2 / Class 1 + class II 100kA SPD on the incoming side of EB Supply and DG Supply with all necessary accessories etc. complete as required. The connections to RYB Phases, Neutral and Earth shall be done using 16 Sq.mm Single Core Flexible Copper conductor cables with less than 0.45m in length<br>SOLAR INCOMER SIDE WITH METERING<br>4 Nos - Provision for fixing Resin Cast CTs<br>1 Nos - Provision for fixing CT Operated Three Phase Energy Meter<br>There shall be KSEBL Sealing Provision of CT Compartment and Metering Compartment<br>1 Set - RYB Indication Lamps with Control MCBs<br>1 Nos - 80A 36kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM Spreader, ON-OFF-TRIP Auxiliary Contact and ON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs<br>1 Nos - 80A 4P AC3 Duty Contactor<br>1 Nos - Digital Phase Failure Relay with Control MCBs 1 Nos - Control Contactor with 2 NO + 2 NC Contacts 3 Nos - 80/5A 5VA CL:1 Resin Cast CT<br>1 Nos - Digital Multifunction Meter measuring V, A, F, KWH, KVA, PF with Control MCBs<br>OUTGOINGS<br>2 Nos - 125A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM, Spreader, Shunt Release, ON-OFF-TRIP Auxiliary Contact, ON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs, Digital Earth Leakage Relay with CBCT and Control MCBs<br>2 Nos - 100A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM, Spreader, Shunt Release, ON-OFF-TRIP Auxiliary Contact, ON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs, Digital Earth Leakage Relay with CBCT and Control MCBs<br>1 Nos - 80A 25kA 4P Thermal Magnetic Type MCCB having 70 to 100% Setting Provision with ROM, Spreader, Shunt Release, ON-OFF-TRIP Auxiliary Contact, ON (Red), OFF (Green), TRIP (Amber) Indication Lamps with Control MCBs, Digital Earth Leakage Relay with CBCT and Control MCBs
od20955/2024_2025 : Supply and installation of thermoplastic insulated, environmental friendly, non corrosive, chemical resistant, shock proof MCB DB including Copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / Isolator etc. fixed on wall using suitable Stainless Steel anchor bolts or screws etc. The DB shall be manufactured in accordance with IEC 61439-3 and with IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 07(5 Joule) in accordance with DIN EN 50102 etc. complete as required.<br>8 Way (8+24) TPN Vertical with provision for fixing 4P MCB / Isolator with 4P RCCB or 8P RCBO as Incomer and TP / SP MCBs as outgoings
od20956/2024_2025 : Supply and installation of thermoplastic insulated, environmental friendly, non corrosive, chemical resistant, shock proof MCB DB including Copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / Isolator etc. fixed on wall using suitable Stainless Steel anchor bolts or screws etc. The DB shall be manufactured in accordance with IEC 61439-3 and with IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 07(5 Joule) in accordance with DIN EN 50102 etc. complete as required.<br>4 Way (8+12) TPN Vertical with provision for fixing 4P MCB / Isolator with 4P RCCB or 8P RCBO as Incomer and TP / SP MCBs as outgoings
od20957/2024_2025 : Supply and installation of thermoplastic insulated, environmental friendly, non corrosive, chemical resistant, shock proof MCB DB including Copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / Isolator etc. fixed on wall using suitable Stainless Steel anchor bolts or screws etc. The DB shall be manufactured in accordance with IEC 61439-3 and with IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 07(5 Joule) in accordance with DIN EN 50102 etc. complete as required.<br>6 Way (8+18) TPN with provision for fixing 4P MCB / Isolator with 4P RCCB or 8P RCBO as incomer and SP MCBs as outgoings
od20958/2024_2025 : Supply and installation of thermoplastic insulated, environmental friendly, non corrosive, chemical resistant, shock proof MCB DB including Copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / Isolator etc. fixed on wall using suitable Stainless Steel anchor bolts or screws etc. The DB shall be manufactured in accordance with IEC 61439-3 and with IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 07(5 Joule) in accordance with DIN EN 50102 etc. complete as required.<br>18 Way SPN with provision for fixing DP MCB / Isolator with DP RCCB or 4P RCBO as Incomer and DP / SP MCBs as outgoings
od58632/2024_2025 : Supply and installation of thermoplastic insulated, environmental friendly, non corrosive, chemical resistant, shock proof MCB DB including Copper bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB / Isolator etc. fixed on wall using suitable Stainless Steel anchor bolts or screws etc. The DB shall be manufactured in accordance with IEC 61439-3 and with IP 65 protection according to IEC 60529, with protection class II and internally embedded gasket made of polyurethane, flame retardant, self-extinguishing with glow wire test at 700 Deg.C in accordance with IEC 60695-2-11 UL subject 94, Impact strength IK 07(5 Joule) in accordance with DIN EN 50102 etc. complete as required.<br>9 Way SPN with provision for fixing DP MCB / Isolator with DP RCCB or 4P RCBO as Incomer and DP / SP MCBs as outgoings
2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.13.1 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.13.2 : Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
od20959/2024_2025 : Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
2.14.3 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.2 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.15.3 : Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.10.3 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Double pole
2.10.4 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
2.11 : Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
od20968/2024_2025 : Supply and laying of 3Cx95+1Cx70+1Cx16 Sq.mm LT ABC Cable of voltage grade 1.1kV conforming to IS 14255 1995 and IS 8130 1984 having Approximate Current Carrying Capacity in Air at 40 Deg.C 235A and Phase conductor short circuit current rating 8.93 kA/1sec. The phase conductors and insulation shall have the specifications of Number of Phase Conductors 3, Nominal cross section area 95 Sq.mm, Material Stranded Class 2 compacted circular Aluminium Conductor, Standard and minimum number of strands in conductor as per IS 8130 1984, Approximate Diameter of conductor 11.4mm, Maximum DC resistance of conductor at 20 Deg.C 0.32 Ohm/Km, Maximum AC resistance of conductor at 90 Deg.C 0.410 Ohm/Km, Rated conductor temperature 90 Deg.C, Conductor temperature during short circuit 250 Deg.C, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.5mm, Volume resistivity at 27 Deg.C 1 x 10 raise to 14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core identification by one, two, three ridges on cores, Core colour Black. The messenger wire and insulation shall have the specifications of Nominal cross section area 70 Sq.mm, Material Stranded Aluminium Alloy conductor, Material Standard as per IS 398 (Part 4) 1979, Maximum DC Resistance at 20 deg. C 0.492 Ohm/Km, Minimum breaking load 19.7KN, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.5mm, Volume resistivity at 27 Deg.C 1 x 10 raise to14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core colour Black. The Street Light Conductor and insulation shall have the specifications of Nominal cross section area 16 Sq.mm, Material Stranded Class 2 compacted circular Aluminium Conductor, Standard and minimum number of strands in conductor as per IS 8130 1984, Maximum DC resistance of conductor at 20 Deg.C 1.91 Ohm/Km, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.2mm, Volume resistivity at 27 Deg.C 1 x 10 raise to 14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core colour Black etc. complete as required
od20969/2024_2025 : Supply and laying of 3Cx70+1Cx50+1Cx16 Sq.mm LT ABC Cable of voltage grade 1.1kV conforming to IS 14255 1995 and IS 8130 1984 having Approximate Current Carrying Capacity in Air at 40 Deg.C 171A and Phase conductor short circuit current rating 6.58 kA/1sec. The phase conductors and insulation shall have the specifications of Number of Phase Conductors 3, Nominal cross section area 70 Sq.mm, Material Stranded Class 2 compacted circular Aluminium Conductor, Standard and minimum number of strands in conductor as per IS 8130 1984, Approximate Diameter of conductor 9.7mm, Maximum DC resistance of conductor at 20 Deg.C 0.443 Ohm/Km, Maximum AC resistance of conductor at 90 Deg.C 0.567 Ohm/Km, Rated conductor temperature 90 Deg.C, Conductor temperature during short circuit 250 Deg.C, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.5mm, Volume resistivity at 27 Deg.C 1 x 10 raise to 14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core identification by one, two, three ridges on cores, Core colour Black. The messenger wire and insulation shall have the specifications of Nominal cross section area 50 Sq.mm, Material Stranded Aluminium Alloy conductor, Material Standard as per IS 398 (Part 4) 1979, Maximum DC Resistance at 20 Deg.C 0.689 Ohm/Km, Minimum breaking load 14KN, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.5mm, Volume resistivity at 27 Deg.C 1 x 10 raise to 14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core colour Black. The Street Light Conductor and insulation shall have the specifications of Nominal cross section area 16 Sq.mm, Material Stranded Class 2 compacted circular Aluminium Conductor, Standard and minimum number of strands in conductor as per IS 8130 1984, Maximum DC resistance of conductor at 20 Deg.C 1.91 Ohm/Km, Insulation material Extruded Cross Linked Polyethylene Compound (XLPE) as per IS 14255 1995, Nominal insulation thickness 1.2mm, Volume resistivity at 27 Deg.C 1 x 10 raise to14 Ohm-cm, Volume resistivity at 90 Deg.C 1 x 10 raise to 12 Ohm-cm, Core colour Black etc. complete as required
90.12.7.28 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 35 sq mm with factory made clamp
90.12.7.29 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 50 sq mm with factory made clamp
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm
90.12.7.31 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 95 sq mm
90.12.7.39 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 6 sq mm with factory made clamp
90.12.7.40 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp
90.12.7.41 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp
90.12.7.42 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp
od20970/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>3.5 core 95 sq mm
od20971/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>3.5 core 70 sq mm
od20972/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required<br>3.5 core 50 sq mm
od20973/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>3.5 core 35 sq mm
od20974/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>4 core 25 sq mm
od20975/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>4 core 16 sq mm
od20976/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>4 core 10 sq mm
od20977/2024_2025 : Supply and laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing excavated trench / pulling through pipes etc. complete as required.<br>4 core 6 sq mm
9.1.21 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
9.1.22 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.24 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 95 sq. mm (45mm)
9.1.32 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 10 sq. mm (25mm)
9.1.33 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm)
9.1.34 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm)
od20978/2024_2025 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.<br>4 X 6 sq. mm
od20979/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required <br>3 1/2 X 95 Sq. mm
od20980/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>3 1/2 X 70 Sq. mm
od20981/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>3 1/2 X 50 Sq. mm
od20982/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>3 1/2 X 35 Sq. mm
od20983/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>4 X 25 Sq. mm
od20984/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>4 X 16 Sq. mm
od20985/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>4 X 10 Sq. mm
od20986/2024_2025 : Supply and providing gland earthing using Gland Earthing Clips / Clamps for following size of PVC insulated and PVC sheathed / XLPE Aluminium conductor cable of 1.1 KV grade as required<br>4 X 6 Sq. mm
14.15.1 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
14.15.2 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.90 mm dia (OD-90 mm & ID-76 mm nominal)
14.15.3 : Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.120 mm dia (OD-120 mm & ID-103 mm nominal)
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.55.3 : Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
90.10.1.1 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )1 module moulded plastic box on surface
90.10.1.2 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface
90.10.1.3 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.4 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )4 module moulded plastic box on surface
90.10.1.5 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
90.10.1.6 : Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )8 module moulded plastic box on surface
1.25 : Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.28.1 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.1 or 2 Module
1.28.2 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.3 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.4 Module
1.28.4 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5 : Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
90.10.3.15 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1.24.1 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
90.10.3.33 : Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.6 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Telephone socket outlet
1.14.1 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
1.14.2 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.14.4 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 6 Sq.mm + 1 x 6 sq.mm earth wire
1.14.7 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
1.14.8 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 4 sq. mm + 2 X 4 sq. mm earth wire
1.14.9 : Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required4 X 6 sq. mm + 2 X 6 sq. mm earth wire
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.26 : Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
od20987/2024_2025 : Supply, installation, testing and commissioning of Shuttered type data socket etc. complete with connections as required
90.6.9.2 : Supplying & Drawing unarmored PVC insulated and & PVC sheathed copper conductor Telephone Pair Cable conforming to ITD specification for indoor application through the existing conduit2 pair
1.53.1 : Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
90.3.20.3 : Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.20.4 : Supply & installation of light fittings on TW round block <br> Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 2X20W LED Lamp with box type fixture
90.3.21.3 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture
90.3.21.4 : Supply & installation of light fittings on 'C/U' shaped flat iron bracket <br> Supply, conveyance, installation, testing and commissioning the light fittings of following types made from 0.5mm CRCA sheet complete with all accessories and lamps etc. directly on wall using 2 nos. 'C/U' brackets made from 20 x 3 mm MS flat, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 2x20W LED Lamp with box type fixture
1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required.
od21001/2024_2025 : Supply and fixing of LEB Bulb up to 12W in the existing PVC batten / angle holder etc. complete as required
90.4.8 : Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
od20988/2024_2025 : Supply, installation, testing and commissioning of 26W, 220V-240V, 50Hz, 1200mm Sweep Brown Colour 5 Star rated BLDC Ceiling Fan with Rated speed of 350 revolutions per minute, Air delivery of 220m3/minute, Ribbed blades and Beautiful bottom motor cover complete with all necessary fittings like 300mm Down Rod, Canopy Set, Shackle Kit, and Twisted Wire and wiring the down rod with 16mm/0.20mm PVC insulated and PVC sheathed 650V / 1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. complete as required
od20989/2024_2025 : Supplying and providing extra H.G conduit down rod of 19mm dia 0.6m long with 16/0.20mm 3 core copper conductor flex wire conforming to relevant IS or with the extended original wiring and giving connection etc. complete as required
od20990/2024_2025 : Supplying and providing extra H.G conduit down rod of 19mm dia 0.9m / 1.0m long with 16/0.20 mm 3 core copper conductor flex wire conforming to relevant IS or with the extended original wiring and giving connection etc. complete as required
od20991/2024_2025 : Supply, installation, testing and commissioning 50W, 240V, 50Hz, 400mm Sweep Wall Fan with 3 blades, Air delivery of 72m3/min, Noise level of 63.5dB, Rated speed of 1350 Revolution per minute, adjustable upward and downward tilt mechanism, Thermal Overload Protector (TOP), pull cord, using mounting accessories and Stainless Steel screws etc. complete as required
od20992/2024_2025 : Supply, installation, testing and commissioning of 50W, 240V, 50Hz, 400mm Sweep Pedestal Fan with 3 blades, Air delivery of 72m3/min, noise level of 63.2dB, Rated speed of 1350 Revolution per minute, adjustable upward and downward tilt mechanism, Thermal Overload Protector (TOP), using mounting accessories and Stainless Steel screws etc. complete as required
od20993/2024_2025 : Supply, installation, testing and commissioning of 20W, 220V-240V, 50Hz, 200mm Sweep Exhaust Fan with Air delivery of 250m3/min, Rated speed of 1550 Revolution per minute, with ON / OFF and Shutter Open / Close through pull cords in the existing opening using necessary Stainless Steel bolts and nuts or screws, making good the damages etc. complete as required
od20711/2024_2025 : Supply and providing earthing with ISI Marked Nickel Sealed Copper Bonded 20mm dia, 3.0 metre long Rod having 250 microns coating thickness with T clamp including Stainless Steel Nuts, Bolts, Round Washers, Spring Washers and other accessories, and providing masonry enclosure with cover plate having locking arrangement with sufficient earthing compound etc. complete as required
od20712/2024_2025 : Supply, installation, testing and commissioning of Tinned Stainless Steel Earth Bench/Terminal Strip of 8 Poles manufactured in accordance with IS / IEC 62305-3:2010 and IEC 62561-2:2012 with screws, nuts, bolts, round and spring washers etc. The Terminal Strip shall have the specifications of minimum Width 25mm, Thickness 4mm, insulations provided at mounting ends etc. complete as required
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.3 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4 : Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
od20694/2024_2025 : Supply, installation, testing and commissioning of Direct Burial Type GRP Street Light Pole of overall length of 3.9 metre with Double Side Arm of 0.5 metre and External GRP Junction Box of suitable size having Four Screw Type Terminal of 16 Sq.mm with the provision for terminating up to 2 Nos of 4C x 16 Sq.mm A2XFY Cable and fixing of 1 Nos of 6A DP MCB and External Lighting Surge Protection Device. The External GRP Junction Box shall only be fixed to the Pole using Stainless Steel clamps and fittings etc. The Pole shall conform to IS 2713 - 1980, IS 875 (PART 3) - 1987, IS 6746, ANSI C 136.20 1990, ASTM D 4923-01, ASTM D 790, ASTM D 5083-10, ASTM D 2584-11, ASTM D 695 etc. and other latest International, Indian Standards and Regulations. The <br>Pole shall have the specifications of Pole Process of Polyester Resin with Glass Fibre by CNC Machines wherein Programmable Logic Control (PLC) is used in a close loop control circuit to control machine movements that ensures<br>placement of right amount of fibreglass at the right place and orientation, Non filled Resin System, Pole Size 3.9 metre (+/- 50 mm), Shaft Length 3900 mm, Burial Depth 900 mm, Nominal Height 3000 mm, Top OD Dia 89 greater than or equal to 5 mm (Approx.), Bottom OD Dia 130 greater than or equal to 5 mm (Approx.), Pole Average Thickness 6 mm (+/-0.5 mm), Glass Content ASTM D2584-11 greater than or equal to 62%, Specific Gravity 1.5 TO 1.95 gm/cm3, Tensile Strength ASTM D 5083-10 greater than or equal to 2100 kg/cm2, Flexural Strength ASTM D 790 greater than or equal to 2100 kg/cm2, Compressive Strength ASTM D 695 greater than or equal to 1100 kg/cm2, Impact Resistance ASTM D 256 greater than or equal to110 kJ/m2, Water Absorption as per ASTM D 570 less than or equal to 0.5%, Surface Colour Shade Polyurethane Paint of Shade Silver, High Wind Load withstand capacity<br>up to 180 km/hr with maximum deflection of 15% etc. complete as required
od20695/2024_2025 : Supply, installation, testing and commissioning of Direct Burial Type GRP Street Light Pole of overall length of 3.9 metre with Single Side Arm of 0.5 metre and External GRP Junction Box of suitable size having Four Screw Type Terminal of 16 Sq.mm with the provision for terminating up to 2 Nos of 4C x 16 Sq.mm A2XFY Cable and fixing of 1 Nos of 6A DP MCB and External Lighting Surge Protection Device. The External GRP Junction Box shall only be fixed to the Pole using Stainless Steel clamps and fittings etc. The Pole shall conform to IS 2713 - 1980, IS 875 (PART 3) - 1987, IS 6746, ANSI C 136.20 1990, ASTM D 4923-01, ASTM D 790, ASTM D 5083-10, ASTM D 2584-11, ASTM D 695 etc. and other latest International, Indian Standards and Regulations. The Pole shall have the specifications of Pole Process of Polyester Resin with Glass Fibre by CNC Machines wherein Programmable Logic Control (PLC) is used in a close loop control circuit to control machine movements that ensures<br>placement of right amount of fibreglass at the right place and orientation, Non filled Resin System, Pole Size 3.9 metre (+/- 50 mm), Shaft Length 3900 mm, Burial Depth 900 mm, Nominal Height 3000 mm, Top OD Dia 89 greater than or equal to 5 mm (Approx.), Bottom OD Dia 130 greater than or equal to 5mm (Approx.), Pole Average Thickness 6 mm (+/-0.5 mm), Glass Content ASTM D2584-11 greater than or equal to 62%, Specific Gravity 1.5 TO 1.95 gm/cm3, Tensile Strength ASTM D 5083-10 greater than or equal to 2100 kg/cm2,<br>Flexural Strength ASTM D 790 greater than or equal to 2100 kg/cm2, Compressive Strength ASTM D 695 greater than or equal to 1100 kg/cm2, Impact Resistance ASTM D 256 greater than or equal to 110 kJ/m2, Water Absorption as per ASTM D 570 less than or equal to 0.5%, Surface Colour Shade Polyurethane Paint of Shade Silver, High Wind Load withstand capacity<br>up to 180 km/hr with maximum deflection of 15% etc. complete as required
od20696/2024_2025 : Supply, installation, testing and commissioning of 72W LED Street Light with luminary specifications of Luminaries wattage 72 Watt (+/- 5%), Input Voltage 230Vac, Input Frequency 50Hz, Input Current 0.313A, Power Factor greater than 0.98, Efficiency 90%, Temperature Class T6, Protection Rating IP 65, Total Weight 2 to 3 Kg, Starting Time Instant, LED specifications of LED type SMD, System Efficiency at the rate of 60 LED Tc 6818 Lumens 103 lm/W, Colour CCT 3000K, Colour Rendering Index RA 70, LED Wattage 66.2W, LED Current 919ma, LED Voltage 72V, Lamp Life 50,000 Hours, Certification LM80, Photo Biological Test Report, LED Drive specifications of Constant Current Type, Input Voltage Range 100 to 320Vac, Frequency 50Hz, Output Protections Short Circuit, Over Voltage / Current / Temperature, External Surge Protection 10KVA etc. complete as required
od20697/2024_2025 : Supply, installation, testing and commissioning of 50W LED Street Light with luminary specifications of Luminaries wattage 50 Watt (+/- 5%), Input Voltage 230Vac, Input Frequency 50Hz, Input Current 0.217A, Power Factor greater than 0.98, Efficiency 90%, Temperature Class T6, Protection Rating IP 65, Total Weight 1 to 2 Kg, Starting Time Instant, LED specifications of LED type SMD, System Efficiency at the rate of 60 LED Tc 4738 Lumens 103 lm/W, Colour CCT 3000K, Colour Rendering Index RA 70, LED Wattage 46W, LED Current 638ma, LED Voltage 72V, Lamp Life 50,000 Hours, Certification LM80, Photo Biological Test Report, LED Drive specifications of Constant Current Type, Input Voltage Range 100 to 320Vac, Frequency 50Hz, Output Protections Short Circuit, Over Voltage / Current / Temperature, External Surge Protection 10KVA etc. complete as required
od20698/2024_2025 : Supply, installation, testing and commissioning of 36W LED Street Light with luminary specifications of Luminaries wattage 36 Watt (+/- 5%), Input Voltage 230Vac, Input Frequency 50Hz, Input Current 0.156A, Power Factor greater than 0.98, Efficiency 90%, Temperature Class T6, Protection Rating IP 65, Total Weight 1 to 2 Kg, Starting Time Instant, LED specifications of LED type SMD, System Efficiency at the rate of 60 LED Tc 6818 Lumens 103 lm/W, Colour CCT 3000K, Colour Rendering Index RA 70, LED Wattage 33.1W, LED Current 460ma, LED Voltage 72V, Lamp Life 50,000 Hours, Certification LM80, Photo Biological Test Report, LED Drive specifications of Constant Current Type, Input Voltage Range 100 to 320Vac, Frequency 50Hz, Output Protections Short Circuit, Over Voltage / Current / Temperature, External Surge Protection 10KVA etc. complete as required
od20699/2024_2025 : Supply, laying, testing and commissioning of 1.5 Sq.mm Multi Core Round Insulated Copper Conductor and Sheathed Flexible cable with compact construction and high insulation resistance. The cable shall have the specifications of Standard FRLS PVC Insulation, FRLS Sheathing in accordance with IS 694, BS 6500, IEC 60227, DIN VDE-0281, IEC 60754-I IEC, 60332-I, BS 4066-I, ASTMD 2843, ASTMD 2863, Conductor Class 5, Number of Conductor Strands 30, Nominal Diameter of Conductor Strands 0.25mm, Nominal Thickness of Insulation 0.6mm, Nominal Thickness of Sheath 0.9mm, Approximate Overall Diameter 8.2mm, AC Current Rating of 18A, Voltage Drop/Amp/Metre for Single Phase AC 31mV, Maximum Conductor Resistance at 20 Deg.C 13.3 Ohms/Km etc. complete as required
od20700/2024_2025 : Excavation of all types of soils for the laying of PVC insulated and PVC sheathed / XLPE Aluminium or copper conductor cable, GI / HDPE / RCC / PVC / Conduit Pipes, Earthing Copper conductors to the required width and depth up to 1.2m and back filling etc. complete as required. The trench dimensions and specifications shall be as per the Electrical Inspectorate, KSEBL and CPWD standards
od20701/2024_2025 : Supply and providing sand cushioning by laying it above the PVC insulated and PVC sheathed / XLPE Aluminium or copper conductor cable, GI / HDPE / RCC / PVC / Conduit Pipes, Earthing conductors in the existing excavated trench etc. complete as required
od20702/2024_2025 : Supply and providing protective covering by laying bricks breadth wise above the PVC insulated and PVC sheathed / XLPE Aluminium or copper conductor cable, GI / HDPE / RCC / PVC / Conduit Pipes, Earthing conductors in the existing excavated trench etc. complete as required
od20703/2024_2025 : Supply and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted / welded to 35 mm X 35 mm X 6 mm GI angle iron, 60 cm long painted with 2 coats of epoxy primer and 2 coats of epoxy paint and fixing the same in ground with cement concrete in M.15 Grade (1:2:4) etc. complete as required
od20704/2024_2025 : Charges for the dismantling of existing Main Switch Board Panel, tracing the existing cables, disconnecting and dismantling the existing cables and connections, providing temporary connection arrangements to the existing cables if necessary etc. complete as required
od20705/2024_2025 : Charges for the dismantling of existing Switch Board / Sub Switch Board / Motor Control Centre Panel, tracing the existing cables, disconnecting and dismantling the existing cables and connections, providing temporary connection arrangements to existing cables if necessary etc. complete as required
od20706/2024_2025 : Charges for the dismantling of all existing Distribution Boards, Wiring Switch Boards, Ceiling Fans, Wall Fans, Exhaust Fans, Tube and other Light Fittings, Conduits, Wires, Ceiling Roses etc. tracing of existing wirings, providing temporary connection arrangements if necessary etc. complete as required
2.21 : Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
od20661/2024_2025 : Supply and fixing 2Kg Dry Chemical Powder (DCP) type fire extinguisher complete with Gun Metal cap, hose with squeeze grip nozzle, wall fixing brackets conforming to BIS: 2171 and with ISI mark etc. complete as required
od20662/2024_2025 : Supply and providing a set of 2 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red oxide paint and written with white paint &quot;FIRE&quot; and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc. complete as required
od20663/2024_2025 : Supply and providing First Aid Box as approved by St. John Ambulance Brigade / Indian Red Cross conforming to IS 2217 : 1963 etc. complete as required
od20664/2024_2025 : Supply and fixing Laminated Shock Treatment Chart duly mounted on a good frame work etc. complete as required
od20665/2024_2025 : Supply and providing tested Industrial Safety Helmet conforming to IS 2925 : 1984 etc. complete as required
od20666/2024_2025 : Supply and installation of the following Energy Meter after getting it duly tested from Electrical Inspectorate / TMR KSEBL. The scope also includes the supply and installation of mounting screws, 1.1 kV Grade 4.0 / 2.5 Sq.mm Flame Retardant Low Smoke (FRLS) or Heat Resistant Flame Retardant (HRFR) PVC insulated single core copper conductor cable for providing connections from Energy Meter to CTs and Incoming Busbar / Cable / Fuse terminals and copper sockets (banana / palm / pin / ring) for providing connections to Energy Meter including crimping etc. complete as required. (All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents)<br>Three Phase LT TOD CT Operated Energy Meter (CL:0.5S)
od20667/2024_2025 : Supply and installation of the following CTs with NABL Certification or after getting it duly tested from Electrical Inspectorate / TMR KSEBL. The scope also includes the supply of copper sockets (banana / palm / pin / ring) including crimping for providing connections to CTs etc. complete as required. (All Statutory or Testing fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents)<br>Up to 200/5A CL:0.5S 5VA Resin Cast CT
od20668/2024_2025 : Preparation and submission of application, drawings and getting approval from Electrical Inspectorate. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents)
od20669/2024_2025 : Preparation and submission of Completion Report, arranging Inspection and obtaining Sanction for Energization Order from Electrical Inspectorate. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents)
od20670/2024_2025 : Preparation and submission of application for regularizing contract demand or load (enhancing / reducing), drawings, agreement and co-ordination with KSEBL for the execution of agreement, for energization etc. complete as required. (*All Statutory fees shall be remitted by the Client / Consumer or it shall be reimbursed on the submission of supporting documents)
Ticket Counter
2.8.1 : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.8 : Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.2.2 : Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up tot floor five level excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3( 1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
5.9.1 : Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.6 : Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.22.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
5.22A.6 : Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.1.5 : Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.10.1 : Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.48 : Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete (steel frame work to be paid separately)
12.49 : Providing & laying on roof pressed clay tile ridge (Mangalore tile) of 20 mm thickness and of approved pattern on steel frame work complete (steel frame work to be paid separately ).
13.1.1 : 12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
od21735/2024_2025 : Supplying and providing Granite Sitting stone bench of size 1.5*.5*.450 including all cost of transportation, erection at site as per direction of engineer in charge(as per quotation)
od21751/2024_2025 : Supply, Conveyance, fixing and commissioning of water purifier -Aquaguard Eden SS RO+UV Water purifier
21.1.2.2 : For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.2.1 : Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
21.3.1 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness
21.3.3 : Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness
Existing Electrical Room Renovation
13.46.1 : Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.99.1 : Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
13.52.1 : Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work
11.21.1.1 : Providing and fixing 10 mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile
Existing Administrative Building Renovation
13.115 : Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work.
100.98.1029 : Engaging Carpenter (average)
EXCLUSIVE OF GST
Note :1 All materials, Items, Equipment shall be best branded items with IS and approved by client/KEL
2:Rate should be inclusive of Insurance,Transportation, delivery and installation cost for all items
3.Rate should be Exclusive of GST.
4.Work should be executed as per DSR/PWD specification and direction of Engineer at site.
5.ELECTRICAL: Note: Rate should be inclusive of preparation of schematic diagram and getting approval from KSEB/Electrical Inspectorate. Statutory fees paid to KSEB/EI shall be paid by us separately.
Make of Electrical equipments/materials
All electrical materials/equipments shall be of best branded items with ISI, strictly as per schedule specification
Panel Boards: CPRI certified reputed manufacturers make
6.Rigid PVCPipes/Casing & Capping - A-ONE/REPUTED MAKE with ISI , Precession, Balco, GEO
7.ALUMINIUM WORK: Make: INDAL, JINDAL in the order of preference and prior sample approval from KEL, Client
8.CEMENT: Make use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
9.CENTERING & SHUTTERING: (Centering and shuttering for different category of work may be considered separately.)
10. ACRYLIC SMOOTH EXTERIOR PAINT/ SYNTHETIC ENAMEL PAINT/WHITE CEMENT BASED PUTTY/ CEMENT PRIMER: Make: Asian, Berger, Nerolas or eq. in the order of pref.
11. STEEL WORK G.I.PIPE: Make: JINDAL, Tata or eq. primary make in the order of preference.
12.RCC: (Assessment of strength of concrete by Cube testing at Approved Govt labs as per IS) Cement make: Use Malabar cement only as per Govt. direction and in case of non availabilty of Malabar cement use Ultra Tech, Dalmia, Ramco or eq. brand in the order of preference.
meconconstructions
A ONE AGENCIES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .