Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.5 LAccepted-AOC | ₹24.5 L Quoted ₹24.8 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹25.5 L+₹67,228 (2.71%)Rejected-Finance DOOR NO 42 2237 KRISHNA BEHIND ERNAKULAM MEDICAL CENTRE CENTURY CLUB ROAD VENNALA KOCHI 682028 | KOCHI | ERNAKULAM | KERALA | 682028 | ₹25.5 L+₹67,228 (2.71%) | L2 | Rejected-Finance unsuccessful bidder |
| 3 | L3₹28.0 L+₹3.2 L (12.8%)Rejected-Finance | ₹28.0 L+₹3.2 L (12.8%) | L3 | Rejected-Finance unsuccessful bidder |
| 4 | L4₹28.5 L+₹3.7 L (14.9%)Rejected-Finance B 101 SURAJ TOWER MIRA BHAYANDER ROAD OPP SAI PETROL PUMP MIRA ROAD EAST THANE 401107 | MIRA ROAD EAST | THANE | MAHARASHTRA | 401107 | ₹28.5 L+₹3.7 L (14.9%) | L4 | Rejected-Finance unsuccessful bidder |
| 5 | L5₹29.9 L+₹5.1 L (20.6%)Rejected-Finance VISHNU NIVAS IRUMBA ARUVIKKARA PO TRIVANDRUM 695564 | THIRUVANANTHAPURAM | KERALA | 695564 | ₹29.9 L+₹5.1 L (20.6%) | L5 | Rejected-Finance unsuccessful bidder |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
9 Feb 2024, 6:00 pmClosed
GE AF Trivandrum
Office of Garrison Engineer AF, Pulayanarkotta, Thuruvikkal Post, Trivandrum-11
COMPREHENSIVE MAINTENANCE OF LIFTS FIRE ALARM SYSTEM NON COMPREHENSIVE MAINTENANCE OF BIO COMPOSTOR AND REPAIR MAINT OF FIRE FIGHTING SYSTEM UNDER GE AF TRIVANDRUM
2024_MES_637108_1
8463
Open Tender
Electrical and Maintenance Works
Works
365 days
Trivandrum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF Trivandrum
₹54,000
Yes
18 Mar 2024
12 Jan 2024
12 Feb 2024
12 Jan 2024
9 Feb 2024
26 Jan 2024
Amount
M & L for comprehensive maintenance and servicing of electrically operated lift 01 No of make KONE Elevators of 544 Kgs capacity (for 8 passengers including lift attendant) controlled by two speed induction motor with 3 landings (Ground + 2 floors) including emergency rescue device at HQ SAC bldg at AF Stn Trivandrum including repairs/replacement of all defective and unserviceable parts as per manufacturer's recommendation during contract period for attending of break down as and when intimated including necessary periodical safety checking and testing of lifts as mentioned in relevant code of practice/IE rule for the safe and efficient performance with all consumables, spares/accessories which ever be required for smooth functioning/trouble free services to the users for 24 hours including Sunday/holiday and submit the maintenance report for smooth functioning of lift, contractor shall also carry out the maintenance of lift in the following period and submit the details in the Performa and as per manufacturer's instruction and procedure laid down:- (a) Fortnightly (b) Monthly (c) Quarterly (d) Yearly
M & L for comprehensive maintenance of electrically operated Lift 01 No of make: Johnson of 884 Kilogram capacity controlled by two speed induction motor with 3 landing (Ground + 2 floors) including emergency rescue device at Station store, Vayu vihar ,AF Stn Trivandrum, contractor shall carry out complete maintenance of lift monthly as per manufacturer's recommendation and also attend and rectify the complaint in case of any break down in the lift as and when intimated including necessary periodical safety checking and testing of lifts as mentioned in relevant code of practice/IE rule for the safe and efficient performance with all consumables, spares/accessories which ever be required for smooth functioning/trouble free services to the users for 24 hours including Sunday/holiday and submit the maintenance report for smooth functioning of lift, contractor shall also carry out the maintenance of lift in the following period and submit the details in the Performa and as per manufacturer's instruction and procedure laid down:- (a) Fortnightly (b) Monthly (c) Quarterly (d) Yearly
NOTE for item 1 to 2 (a) (i) The rate quoted shall be inclusive of all spares required during comprehensive maintenance period. (ii) Rate quoted shall be exclusive of refinishing, repair or replacement of the following:- (b) Elevator car enclosure (c) Elevator car and landing door panels, gates (d) LED Bulbs (15W) and alarm buzzer/bell (e) Cabin fans (f) Main switch in the machine room and incoming electrical wiring to main switch (g) Batteries for ARD
(h) The Above maintenance includes complete maintenance of existing lift & Bio composting machine by regularly and systematically examining adjusting fabricating as require for smooth and efficient functioning of the equipment / lift. Cost of all spares items are deemed to be included in OEM AMC schedule but required at site for smooth operation of lift shall be paid to contractor on this account (j) The Maintenance of lift shall be done through (OEM) the tenderer has to submit intent of MOU from OEM the tenderer has to submit intent of MOU from OEM within fifteen days of acceptance of tender failing which the contract will be liable to be cancelled and work shall be executed at risk & cost of the contractor. Contractor shall conclude AMC with OEM and copy of the agreement will be submitted to Engr-in-charge and GE before commencement of AMC, no payment shall be made to contractor without submission of valid AMC agreement. (k) The contractor /OEM shall provide mechanic and this mechanic shall be available round the clock i, e. 24 hrs. for emergency break down attendance and rescue of trapped persons all as directed by Engr-in-charge.
(l) The contractor shall obtain signature of Authorized Representative of GE and in token of satisfactory completion of defects. Any minor complaint requiring no spare part shall be rectified within 2 hour & if requiring minor parts, shall be rectified within 4 hrs. Any major complaint requiring major spare part/repair shall be rectified within 48 hours. In case delay in rectification of any minor complaint, a penal recovery @ Rs 100/- per hour shall be imposed upon the Contractor & in case of delay in major repair of the lifts for more than 48 hours & up to 10 (Ten) days, penalty on the Contractor for a sum of Rs 2000/- per lift per day.
M & L for non-comprehensive maintenance of Fully automatic Mechanical compositing machine based on the technology of heating, crushing mechanism and thermophilic process (50 to 55 degree C), electrically operated by 3 phase 12.5 HP geared motor with compositing capacity 200 Kg (Food or wet waste 100% segregated bio-degradable) per day all wetted parts made up of stainless steel grade SS 304 complete with in-built voltage stabilizer, crusher and air pre-heating system and control panel etc. of Make Smart Enviro Systems, Model SMART Xpress 200 of capacity 200 Cum/day installed at Vayu Vihar area, AF Station, Trivandrum. Contractor shall carry out complete annual maintenance as per manufacturer recommendations and also attend and rectify any complaint in case of any break down and submit the Maintenance Report to the Engineer-in-Charge complete all as specified and directed. Note: Each Job to be done in each quarter
Note for Item for 03: In case delay in rectification of any minor complaint, a penal recovery @ Rs 100/- per hour shall be imposed upon the Contractor & in case of delay in major part of the Bio Compositor for more than 48 hours & up to 10 (Ten) days, penalty on the Contractor for a sum of Rs 2000/ day shall be imposed.(ii) Contractor is bound to smooth functioning of the Smart Enviro Systems, Model SMART Xpress 200 of capacity 200 Cum/day. Contractor shall be responsible to display the operating manual and safety instruction on a board and display near the installation. Contractor shall prepare a " DO/DON'T " chart for operation of biocompositor in A2 size board and display it near the installation with necessary fixing arrangement as directed by Engr-in-charge.
Supply only Crusher oil seal of suitable size of Bio composter 200 Kgs of capacity Make: Smart enviro systems.
Supply only Enzyme power 150 gm. packet made of Smart enviro systems 200 Capacity all as specified and directed
Supply and fix Mixer bearings Make : SKF all as specified
Supply and fix Mixer shaft sprocket 40 feet 1 inch all as specified
Supply and fix battery 6 V for lift of capacity 544 Kg at Command HQ
M& L for cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots and trees and rubbish up to a distance a 30 mtr outside / inside the periphery of the area under clearance of area around the installation complete all as specified. Note: necessary penalty will be raised against Contractor, if area found dirty.
Dismantling three phase 440 volts motors of 12.5 HP capacity, cutting and removing burnt motor winding, cleaning the slots and rewinding with approved quality super enamelled copper conductor winding wire of existing size and capacity including insulating materials, varnishing baking etc. and reinstalling in existing position, testing etc. complete all as specified and directed.
Supply & Fix in replacement of Fire Hydrant Valves conforming to IS 5290, with ISI mark, SS body, single headed type 63mm dia oblique type with female instantaneous hose coupling adaptor complete with gunmetal blank cap and chain. Make: Newage, Kartar
Supply & Fix in replacement of Fire Fighting Delivery Hoses Reinforced rubber lined type in 15M of length, 63mm dia, IS marked and tested to a bursting pressure of 32kg/sq.cm and with heavy quality SS/ aluminium metal couplings with IS mark. (IS 903) Make: Newage/ Kartar
Supply & Fix in replacement of Double Hose Cabinets to accommodate one pieces of hose pipes along with one pair of male and female coupling and one branch pipe. The cabinet is made up of MS sheet, glass fronted with hinged doors, painted with scarlet red outside and off white inside and with lock and key. Make: Friends Eng./ Kartar
Supply & Fix in replacement of SS Short Branch Pipes 63mm dia complete with hexagonal based nozzle. Make: Newage /Kartar
Supply & Fix in replacement of Air Release Valve. Make : Kartar/ Newage
Supply & Fix in replacement of First aid Hydraulic Hose Reels complete with swing type drum 20mm dia rigid hose having a length of 25M with stop cock and chrome plated shut off nozzle on one end including testing & commissioning & all other necessary fixing materials and made functional. Make : Kartar/ Newage
Supply & Fix in replacement of Foot Valve of the following size conforming to IS specifications and with ISI mark. Valves with cast iron body, seat material black nitrile rubber and with stainless steel spindle. Make: Newage/ Kartar.
Size: 150 mm dia
Size: 100 mm dia
Supply & Fix in replacement of Butterfly valve of the following size conforming to IS specifications and with ISI mark. Valves with cast iron body, seat material black nitrile rubber and with stainless steel spindle. Make: Newage/ Kartar.Size: 100 mm dia
Supply & Fix in replacement of Non Return valve of the 100 mm dia size conforming to IS specifications and with ISI mark. Valves with cast iron body, seat material black nitrile rubber and with stainless steel spindle. Make: Kartar.
Supply & Fix in replacement of Fire Hydrant Female Coupling conforming to IS 5290, with ISI mark, SS body, single headed type 63mm dia oblique type with female instantaneous hose coupling adaptor complete with gun metals blank cap and chain. Make: Newage, Karta
Supply & Fix in replacement of Hose Reels Shutoff Nozzle complete 25mm gun metal with stop cock and chrome plated on one end including all other necessary fixing materials and made functional.Make : Kartar/ Newage
Supply & Fix in replacement of motor starter control panel with DOL starter unit & ON Off push buttons, ammeter & Volt meter set indication lamps etc. and with wired remote control station unit.
Supply & Fix in replacement of GI ‘ B’ class pipes of the following sizes conforming to IS 1239 with ISI mark with required pipe specials such as bens, flanges tees nuts and bolts, gaskets etc. with necessary pipe supports and the piping shall have anticorrosive primer coating over which two coats of signal red paints. Make : TATA/ JINDAL
100 mm dia
150 mm dia
Providing comprehensive maintenance of fire detection system in various buildings under HQ SAC , servicing and testing the entire system/ cleaning of detectors etc. as per specification in each quarterly (90 days) i.e. attending breakdown calls within 24 hrs. of intimation etc., complete as required for the period of 01 year as per details given below. Note: Compliant register and quarterly report must be submitted alongwith the RAR by the contractor.
AFNET : Fire alarm panel 06 Zone ( Conversional - Ravel - 2558) Manual Call point , electronic sounders, smoke/heat detectors
AFNET Tel : Fire alarm panel 06 Zone ( Conversional - Ravel RE - 10 D) Manual Call point , electronic sounders, smoke/heat detectors
COORD : Fire alarm panel ( Addressable - Morely IAS-DX1) Manual Call point , electronic sounders, smoke/heat detectors
CHOC : Fire alarm panel 06 Zone ( Conversional - RE - 150 D) Manual Call point , electronic sounders, smoke/heat detectors
DCN/SATCOM : Fire alarm panel 08 Zone ( Conversional - Ravel RE - 150 D) Manual Call point , electronic sounders, smoke/heat detectors
DCN : Fire alarm panel 08 Zone ( Conversional - Morely IAS Horizon ) Manual Call point , electronic sounders, smoke/heat detectors
Auditorium : Fire alarm panel ( Addressable - Ravel, Avani ) Manual Call point , electronic sounders, smoke/heat detectors
AFNET SITE -II : Fire alarm panel 08 Zone ( Conversional - Morely IAS Horizon ) Manual Call point , electronic sounders, smoke/heat detectors
Supply and fixing in replacement include testing and Commissioning of Conventional Type Manual Call Point
Supply and fixing in replacement including testing and Commissioning of Addressable Manual Call Point
Supply and fixing in replacement including testing and Commissioning of Addressable Smoke Detector
Supply and fixing in replacement including testing and Commissioning of Conventional Smoke Detector
Repairing, Greasing and Servicing of 30HP Main Fire Pump, painting, gland packing and tightening of all connections including earth connection. (Head Quarter Building)
Repairing, Greasing and Servicing of 20HP Fire Jockey Pump, painting, gland packing and tightening of all connections including earth connection. (Head Quarter Building)
Repairing, Greasing and Servicing of 20HP Fire Booster Pump, painting, gland packing and tightening of all connections including earth connection. (Bheema Tower)
Repairing, Greasing and Servicing of 20HP Fire Booster Pump, painting, gland packing and tightening of all connections including earth connection. (Arjun Tower)
Repairing, Greasing and Servicing of 20HP Fire Booster Pump, painting, gland packing and tightening of all connections including earth connection. (Krishna Tower)
Repairing, Greasing and Servicing of Fire Brigade Inlet complete all as specified and directed
Repairing, Greasing and Servicing of Fire Hydrant Valve complete all as specified and directed
Repairing, Greasing and Servicing of Hose Reel complete all as specified and directed
Repairing, Greasing and Servicing of Hose Cabinet including cleaning, scrapping of rusted surface and painting complete all as specified and directed
Repairing and Servicing of Delivery Hose complete all as specified and directed
Repairing and Servicing of Fire Alarm Control Panel including the spares required to smooth/proper functioning of the panel complete all as specified and directed
Repairing and Servicing of Manual Call Point complete all as specified and directed
Repairing and Servicing of Sounder complete all as specified and directed
Repairing and Servicing for Fire Pump Starter of any capacity including all necessary spares as per requirement complete all as specified and directed
AAG INDIA PVT LTD
General Engineering and Constructions
Saviour Security Systems
VISHNU
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .