| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹38.6 L+₹1.7 L (4.72%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹38.7 L+₹1.9 L (5.03%)Rejected-Finance | L3 | Rejected-Finance BEING L3 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Dec 2023, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIR / REPLACEMENT OF INTERNAL ELECT / DB / SUB MAIN WIRING, LED LIGHT BAY LIGHTS, REPAIR OF CEILING FANS AND GEYSER AT MD AND OTM ACCN AT AFS VADODARA
2023_MES_630721_1
8848/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
4 documents required · 4 mandatory
₹500
GE AF BARODA
₹80,000
Yes
7 Feb 2024
1 Dec 2023
4 Jan 2024
1 Dec 2023
28 Dec 2023
15 Dec 2023
2 Dec 2023 - 8 Dec 2023
Amount
Taking down carefully copper / Aluminium point wiring of light, fan, socket or power points complete including fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical, fan regulators, light or power sockets etc and removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
M&L for point wiring with using 1.5 Sqmm (nominal area) stranded copper conductor single core PVC insulated & unsheathed cable 1100 volts grade in and incl PVC casing and caping of suitable size fixed on surface all as directed with using new sunken type pressed steel box/terminal boxes for mounting fittings/junction boxes not less than 1.6 mm thick duly painted with two coats of black bituminous paint over a coat of red oxide primer with and incl all accessories and using 1.5 Sq mm (nominal area) stranded copper conductor single core conductor PVC insulated & unsheathed cable as in earth wire connected to common earth dolly complete all as specified and directed for the following:-
Note for item No 2.00 : (i) The quoted rates shall deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of PVC casing caping shall be determined on permissible No of runs of wires as specified in SSR part I (2010) and as specified in preamble 1 (a) to (q) of section 19, sub section 13 - Internal work of SSR-II, 2020.
One light point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size
One light point controlled by two, two way switches
One bell point controlled by one bell push
Description all as per item No. 2.00 here-in-before but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Description all as per item No. 2.00 here-in-before but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Material and labour for point wiring with using 2 x 1.5 Sqmm (nominal area) stranded copper conductor single core, PVC insulated (FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in existing concealed PVC conduit any type as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box and Moduler cover plate for fixing of switch socket, fan regulators etc and incl all accessories complete all as specified and directed for the following:-
Note for item No 5.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ.
One light point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switches.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size
One bell point controlled by one bell push
One light point controlled by two, two way switches
Description all as per item No. 5.00 here-in-before but using 2.5 Sqmm PVC insulated, unsheathed copper conductor cable and earth conductor of 2.5 sqmm copper cable for one 3 pin socket outlet 15 Amps on independent board.
Description all as per item No. 5.00 here-in-before but using 4 Sqmm PVC insulated, unsheathed copper conductor cable and earth conductor of 4 sqmm copper cable for one 3 pin socket outlet 15 Amps on independent board.
Material and labour for concealed point wiring with using 2 x 1.5 Sqmm (nominal area) stranded copper conductor single core, PVC insulated (FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1x 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in and including concealed rigid PVC conduitsize not less then 20mm dia as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box and Moduler cover plate for fixing of switch socket, fan regulators etc and incl all accessories complete all as specified and directed for the following :-
Note for item No 8.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light point controlled by one, one way switch.
One fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One 3 pin 5 Amps socket outlet on independent board with cable of 1.5 sqmm size
One light point controlled by two, two way switches
One bell point controlled by one bell push
Description all as per item No.8.00 here-in-before but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Description all as per item No.8.00 here-in-before but wiring with 4 sqmm multistranded copper conductor unsheathed and 4 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board.
Note: (for item 01 to 10): Being maintenance work Contractor shall carry out even single point wiring or associated work as per the direction of concerned JE(E/M)/AGE E/M. In case contractor fails to execute the allocated work within 3 days from the date of allocation a recovery at the dauble of quoted rate shall be levied upon contractor and no claim whatsover on this account shall be entertained by the Government.
M & L for sub main wiring using two single core 6 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping/PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 6 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 6 sqmm and one run of 6 sqmm earth wire and one run of PVC conduit / casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Casing Caping / PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 4 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit / casing caping shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the unit rate quoted .
S & F switch piano Modular type single pole one way 6 Amp 240 Volts complete all as specified and directed.
S & F switch piano Modular type single pole one way 16 Amp 240 Volts complete all as specified and directed.
S & F switch piano Modular type single pole two way 6 Amp 240 Volts complete all as specified and directed.
S & F modular socket outlet 6 Amps 3 pin 2 module 240 Volt complete all as specified and directed.
S & F socket outlet 6/16 Amps 5 pin 2 module 240 Volt complete all as specified and directed.
S & F Fan Regulator 2 Module FSC Modular type 240 Volts complete all as specified and directed.
S&F piano switch flush type 5 Amps single pole, one way, 230 volts AC circuit complete all as specified and directed.
S&F in replacement 5 Amps Socket only 3 Pin flush type complete all as specified and directed.
S&F in replacement 15 Amps Socket only 3 Pin flush type complete all as specified and directed.
S&F in replacement 15 Amps Switch only flush type complete all as specified and directed.
S&F in replacement switchsocket combination 2 in 1, 3 pin, 5 amps flush type universal 240 Volt complete all as specified and directed.
S&F in replacement switch socket combination 3 pin 16 Amp 2 flush type complete all as specified and directed.
S&F in replacement switch piano flush type single pole two way 5 Amp 240 Volts. complete all as specified and directed.
S&F in replacement switch socket combination 2 in 1, 3 pin, 5 Amps flush type 240 Volt complete all as specified and directed.
S&F in repair Stepped/socket type electronic fan regulator heavy duty typeA/C 240 V.complete all as specified and directed.
S&F Bell push flush type single pole 5 Amp 240 Volts complete all as specified and directed.
S&F in replacement modular switch one way 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular switch one way 16 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular switch two way 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular bell push way 6 Amps 1 module 240 Volts complete all as specified and directed.
S&F in replacement modular socket outlet 6A 3 pin 2 module 240 Volts. Complete all as specified and directed.
S&F in replacement modular socket outlet 6A/16 5 pin 2 module 240 Volts. Complete all as specified and directed.
S&F in replacement modular fan regulator 120W-2 module 240 Volts. Complete all as specified and directed.
S&F modular Bell push flush type single pole 6 Amp 240 Volts one module. Complete all as specified and directed.
S&F in replacement Bell ding dong type, one way, 240 volts, AC, ISI marked.Complete all as specified and directed.
S&F ceiling rose surface bakelite three terminal 65 x 50 mm three terminal 250/230 volts ISI marked. Complete all as specified and directed.
S&F in repair straight /Angle bulb holder pvc body, material to be supplied as per demand of qty is ordered by Engineer -in- charge as per site requirement. Complete all as specified and directed.
S&F in repair TPN DBs Vertical type load line 4 way DB 415 volt with provision for FP as incomer and SP complete all as specified and directed.
S&F in repair TPN DBs Vertical type l4 way DB 415 volt with provision for FP as incomer and SP as outgoing complete all as specified and directed.
S&F in repair TPN DBs Vertical type load line4 way DB 415 volt with provision for FP as incomer and SP as outgoing complete all as specified and directed.
S&F in repair sheet metal enclosure for single pole and neutral 12 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure for single pole and neutral 08 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.
S&F in repair sheet metal enclosure for single pole and neutral 04 way DB 240 voilts, 100 Amp rated bus bar complete all as specified and directed.
S&F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single MCB SP 20 Amps complete all as specified and directed.
S&F in repair DB's MCB's of MCB SP up to 40 Amp 240 Volts 9 KA rupturing capacity conforming to IS-8828 of the undermentioned type and ratings complete all as specified and directed.
S&F in repair MCB SP & N up to 63 Amp 240 Volts complete all as specified and directed.
S&F in repair MCB four pole up to 80 Amp 415 Volts complete all as specified and directed.
S&F in repair MCB TP &N (4P) up to 100 Amp 415 Volts complete all as specified and directed.
S&F in replacement PVC rectangular block for mounting switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100mm x 100mm x 50 mm complete all as specified and directed.
Description all as per item Ser No 51.00 here-in-before but for size 175x100x50 mm deep
Description all as per item Ser No 51.00 here-in-before but for size 200x150x50 mm deep
Description all as per item Ser No 51.00 here-in-before but for size 250x200x50 mm deep
Description all as per item Ser No 51.00 here-in-before but for size 350x200x50 mm deep
S&F single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
S&F three phase electronic meters temper proof LCD display with polycarbonate cover 415 V,10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH Class 1 complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet,10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing LED bulk head luminare10 watt, 220 V AC complete with driver, holders & LED lamp suitable for wall/roof/ ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F LED light fittings small 6 watt round/square type white/yellow complete with choke/driver complete all as specified and directed.
S&F recess mounted down lighter 6 Watts complete all as specified and directed.
S&F LED Inverter Street light fittings 30 watt, 220 V AC complete with driver, holders & LED lamp suitable for wall/roof/ ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply only LED bulb Lamp 09 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat shrink complete all as specified and directed.
Supply only LED bulb Lamp 12 Watts Retrofit B22 holder type base wth polycorbonate diffuser and alluminiun heat shrink complete all as specified and directed.
Dismantling the Geyser of any capacity and of any description material and labour for cleaning and de-scaling the inner tank and other parts / accessories including inlet, outlet , overflow Geyser element, thermostat , ‘U’ assembly etc. with brush, cleaning rod, and using / circulating concerned de-scaling solution mixed with water in suitable proportion till the complete deposits /scale is removed as approved by Engineer-in-Charge, brazing for stopping leakage of copper inner tank/gas welding for inner steel tank, re- assembling the complete Geyser after cleaning, Fixing and installation of Geyser in position and testing to the entire satisfaction of engineer-in-Charge complete all as specified and directed.
Taking down and refixing storage type water heater from wall by disconnecting the electric connection and water inlet/outlet connection from main and repairing the water heater storage type capacity 25 ltrs of any type and make, checking the serviceablity of all parts such as inner vesser, rubber gasket, non return valve, heating element, thermostat etc and refixing the same after replacing of unserviceable parts and assembly complete (considered as one unit) and installing and testing the same as per the direction of Engineer-in-Charge complete all as specified and directed. Note :- Supply only for parts such as Heating element, Thermostate etc against unserviceable parts shall be measured and paid for separately under relavent items given below.
Description all as per item No 68.00 here-in-before but for capacity 50 ltrs complete all as specified and directed.
Supply only heating elements, 1.5/2 KW any type any size ISI mark 230 volts complete all as specified and directed.
Supply only thermostat immersion point type 15 Amps, 230-250 volts/AC ISI marked complete all as specified and directed.
Supply & fix in replacement, stainless steel flexible conneciton pipe with brass check nuts complete as per site requirement complete all as specified and directed.
Supply & fix in replacement of indicator lamp assembly for geyser complete all as specified and directed.
Supply and fix syphon assembly suitable for 25/50 ltr geyser complete including nuts and washer complete all as specified and directed.
Supply and fix geyser brass tank for 25/50 ltr geyser complete including nuts, washer, glass wool etc complete all as specified and directed.
Supply and fixing 15 Amp plug top complete all as specified and directed.
Supply and fixing earth industrial plug top for socket for industrial socket metal clad suitable for 20 Amps metal clad MCB DB complete all as specified and directed.
Supply and fixing earth industrial socket metal clad suitable for 20 Amps 240 volts metal clad MCB DB complete all as specified and directed.
Supply only FR electrical insulation tape nominal size 0.125mm thickness x 1.8 cm width x15 mtr length as IS CODE 1728 As per sample complete all as specified and directed.
Supply and fix 4 sq mm 3 core flexible copper cable for maintenance of geyser and cooling appliances. Role of 90 RM complete all as specified and directed.
Supply and fixng Hylam sheet Size 7” x 9”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 9” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 6” x 6”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixng Hylam sheet Size 9” x 11”x3 mm thick with Brass screw and washers with necessary slots reqired for mounting the fixtures complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with,1400RPM, heavy duty blades, and frame and louvers including taking out u/s exaust fan from site complete all as specified and directed.
Supply only of exhaust fan, steel body heavy duty turboforce, AC single Phase. 230 V of size 450 mm sweep, 1400 RPM air delivery 1950 CM with, 4 blades, and frame and louvers grey colour, dust resistant. complete all as specified and directed.
M&L for making hole of dia 300mm/450mm(inner dia) with using 300mm/450mmdia hume pipe in existing wall (wall thicknes upto 300mm) for fixing of exhaust fan and making good the existing surface to match with existing complete all as specified and directed.
Supply, fixing and fabrication and testing desert cooler in GI body sheet with and including cooler fan motor size/sweep 450mm (fan blade only) 230 Volts, Single phase 50 Hz, 1400 RPM, heavy duty single sheet, totally enclosed. The overall dimesnions of the desert cooler shall not be less than 690mm x 690mm x 1020mm with and including following accessories each complete all as specified and directed.
(a) Air grill of suitable size made out of 0.5mm PGI sheet including GSS arrangement with a knob for easy and smooth movement. (b) Front & Side panel made out of 1mm thick PGI sheet of suitable size and shape. (c) Water tank height should not be less than 11 inch made out of 2mm thk PGI sheet. (d) Submersible pump electric driven single phase 230 volts, 50 Hz of suitable discharge and head but motor capacity not less than 18 watt. Make : Khaitan/Crompton or equivalent make. (e) Service cord of 3 Core copper wire 1.5 Sqmm with plug top 5 Amp length not less than 2 metres. (f) Electronic fan dimmer 1000 watts AC 230 Volt for controlling the fan speed. (g) Complete electric wiring of desert coolers as required to operate fan and pump along with 5 Amp switches . (h) Make of cooler fan motor: Khaitan/ Havells/Crompton Greaves (j) Make of PGI sheet. Tata/Jindal/National (k) Make of PGI sheet. Tata/Jindal/National
M&L painting enamel white paint by spraying on ceiling fans/exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavities with fine finishing surface by filler one coat after removing/cleaning all dust/dert etc including taking down/ refixing complete all as specfied and directed. Note:- marking/numbering with MES No/Qtr no included in item rates, no extra payment shall be made for marking/numbering.
Attending the complaints lodged by the occupants/users including Identifying and rectifying the fault as per the complaint lodged by the user in day time 8.30 Hrs to 1730 Hrs like No light/loose connection/ MCB tripping/ceiling fan/exhaust fan/air circulator/ cabin fan such as hanging/ dismantling/ loose connection etc complete all as specified and directed
Supply and fixing capacitor of 2.5 MFD complete all as specified and directed.
M & L for rewinding of ceiling fans 1200/1400mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of heavy grade (ISI mark ) copper winding wire, duly providing leatherite sheets, cotton tape, insulation sleeves, varnish, etc, 6 month waranty period shall given by the dealer/contractor after repair, complete incl taking down, dismantling, reassembling and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed Note:- Contractor shall make the suitable arrangement at Darjipura (MES) premises for replacing of accessories, testing upto the satisfactory level in front of concerned E/M in charge without fail.
M & L for rewinding of Exhaust fan 300 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc, 6 month waranty period shall given by the dealer/contractor after repair, complete incl taking down, dismantling, reassembling and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L for rewinding Exhaust fan 450 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc, 6 month waranty period shall given by the dealer/contractor after repair, complete incl taking down, dismantling, reassembling and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed
M & L rewinding for Cabin fan 400 mm sweep/PVC Exhaust fan, strip opening and removal of burnt winding wire, rewinding the fans with suitable size of of heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc, 6 month waranty period shall given by the dealer/contractor after repair, complete incl taking down, dismantling, reassembling and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
M & L for rewinding of air circulator 600 mm sweep, strip opening and removal of burnt winding wire, rewinding the fans with suitable size ofof heavy grade (ISI mark ) copper winding wire, duly providing leathoride sheets, cotton tape, insulation sleeves, varnish, etc, 6 month waranty period shall given by the dealer/contractor after repair, complete incl taking down, dismantling, reassembling and refixing at site and shifting/transporting to wksp including testing complete all as specified and directed.
S & F MS clamps (Standard size as per site of DJP) with rubber real with MS nut, bolts, check nut & split pin complete all as specified and directed.
Supply and fix anti suicide fan rod (12") with brass clamp including rubber nuts bolt cotter pin white, MS pipe zinc plated, 19 mm OD, 1.8 + /- 0.05 mm spring set grade 3 carbon steel material zinc plated , MSME tested for, performance test and opening at impact load of 22 kgs + and spring 'hidden in the pipe' will expand to about 1 mtr or more, complete all as speified and directed. Note :- rate of clamp included in item rate Make :- Gold life or any other equivalent as approved by GE
M&L for changing of fan bearing 6201/6202 of ceiling fan of any capacity any size complete all as specified and directed Note: Replacement of bearing to be carried out at power house at AFS Darjipura only exceptional case where lathe work is required then only fan to be taken at workshop.
M&L for changing of bearing/bush of exhaust fan/cabin fan/air circulator of any capacity any size all as specified and directed Make SKF/NBC Note: Replacement of bearing to be carried out at power house at AFS Darjipura only exceptional case where lathe work is required then only fan to be taken at workshop complete all as specified and directed.
Overhauling/serviceaing of ceiling fans 1200/1400mm, Exhaust fan,wall mount fan any size/ any capacity including cleaning, greasing, oiling and other minor repair and also including taking down and refixing after servicing complete all as specified and directed.
Supply and fix 23/.0076 sq mm 2 core flexible copper cable for maintenance. Role of 90 RM complete all as specified and directed.
Supply& fix highway light 120 watt LED highbay with aluminium die cast housing IP 65 with high lumen efficiency of the rated wattage complete all as specified and directed.
Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc complete all as specified and directed.
Supply and fix electric wall fan high speed 3 speed control complete with all accessories required to fix on wall etc complete all as specified and directed.
Supply and fixing recessed mounted LED tube light fitting ENERGY Efficient 1x36 Watt 1x 4 feet tile in CRCA housing with opal diffuser suitable to fix in false ceiling complete all as specified and directed.
Supply and fixing LED bed side light fitting (bed side reading light) 3 watt as per sample complete all as specified and directed.
Supply and fixing LED wall light fitting(for name plate/showcase light) 15 watt as per sample complete all as specified and directed.
Supply and fixing AAA battery for remote hand set complete all as specified and directed.
Supply & fix Exhaust fan louvers 300mm/450mm complete all as specified and directed.
M & L for Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and aking good, cutting exceeding 20cm girth complete all as specified and directed
Supply only of PVC conduit size 25mm Rigid non-metallic PVC conduit exclusive of boxes (junction /terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth, tube ends and fixing accessories, including chase cutting, such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed
motwani and associate
Shiv Kripa Tradimg
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .