| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC | L1 | Accepted-AOC Accepted and awarded | |
| 2 | L2₹6.8 L+₹33,803.02 (5.19%)Rejected-AOC | L2 | Rejected-AOC Higher rate hence rejected. | |
| 3 | L3₹7.0 L+₹52,793.02 (8.11%)Rejected-Finance NORTH BEYPORE CALICUT 15 KERALA | KOZHIKODE | KERALA | 612906 | L3 | Rejected-Finance L3 | |
| 4 | L4₹7.3 L+₹77,448.02 (11.9%)Rejected-Finance | L4 | Rejected-Finance L4 | |
| 5 | L5₹7.4 L+₹86,428.52 (13.3%)Rejected-Finance | L5 | Rejected-Finance L5 |
Tender Value
₹7.8 L
EMD Value
₹11,670
Closing Date
3 Aug 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Electrical)
Executive Engineer (Electrical) Office of the Executive Engineer Electrical Electrical Division Engg Department University of Calicut Calicut University P O Malappuram District Kerala 673635
Electrification for the first floor of CUTEC building at Poomala
2022_UoC_500931_1
D3/E-Tender No.10/2022-23
Open Tender
Electrical Works
Item Rate
60 days
University of Calicut
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,837
₹11,670
27 Sept 2022
25 Jul 2022
6 Aug 2022
25 Jul 2022
3 Aug 2022
25 Jul 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group A. (1.10.1)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group B. (1.10.2)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required - Group C. (1.10.3)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2x1.5 sq.mm + 1x1.5 sq.mm earth wire. (1.14.1)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire. (1.14.2)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire. (1.14.7)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. (1.14.4)
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required - 4 X 6 sq. mm + 2 X 6 sq. mm earth wire. (1.14.9)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 6 sq. mm. (1.17.30)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm. (1.17.3)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 6 x 1.5 sq. mm. (1.17.6)
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm. (1.17.12)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm. (1.21.1)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm. (1.21.2)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch. (1.24.3)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 amp socket outlet. (1.24.5)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 3 Module (100mm X 75mm). (1.27.2)
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. (1.33)
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess, including providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets and 2 Nos. 5/6 A modular switches, connection etc. as required. (For light plugs to be used in non residential buildings). (1.56)
Supplying and fixing PVC batten/ angle holder including connection etc. as required. (1.58)
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(1.26)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing vand commissioning etc. as required.Single pole. (2.10.1)
Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. (2.12.1)
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25 amps. (2.14.1)
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole. (2.10.4)
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.(2.11)
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. (2.13.1)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps. (2.15.1)
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps. (2.15.2)
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32amps 240 volts "C" curve DP MCB complete with connections, testing and commissioning etc. as required. (2.16)
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. (5.14)
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. (5.17)
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator2+12 way, Double door. (2.3.8)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 10 sq. mm (25mm). (9.1.32)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 16 sq. mm (28mm). (9.1.33)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 4 X 50 sq. mm (35mm). (9.1.36)
Supplying and fixing 40A to 63 A ,TP MCB 415 V ,10 KA,"C" Curve ,miniature circuit breaker suitable for inductive load in the existing MCB DB complete with connections, testing and commissioning etc.as required. (od43120/2022_2023)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.4 core 6 sq mm. (90.12.5.39)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 10 sq mm. (90.12.5.40)
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 4 core 16 sq mm. (90.12.5.41)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 10 sq mm with factory made clamp. (90.12.7.40)
supplying and making end termination with brass compression gland and Aluminium lugs for following size of PVC sheathed /XLPE aluminium conductor cable of 1.1kv grade as required. 4 X 6 sq.mm. (od38629/2022_ 2023)
Providing and fixing 10 SWG copper wire on surface or in recess for loop earthing as required. (od38506/2022_ 2023)
Supply, Installation ,Testing and commissioning of 400 mm AC Sweep oscillating type wall mounting fan with suitable clamp and bolt. (od38328/2022_2023)
Supplying and Fixing 7W LED Bulb in the existing Bulb Holder. (od38329/2022_2023)
Supplying 305 mm sweep, 1400 rpm Heavy Duty Exhaust fan working on 230 V A/C. (od38330/2022_2023)
Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required. (90.4.8)
Conveyance, installation , testing and commissioning of exhaust fans of size up to 450mm in the existing opening, fixing necessary anchor bolts / bolt and nuts etc., as required including giving connections with the supplied wire along with the exhaust fan. (90.4.10)
Supply and laying 20 mm Corrugated PVC flexible conduit. (od38331/2022_2023)
Wiring plug point along with wiring of light point including supply fixing 5A flush type modular switch and 3 pin plug socket in combined position.(Combined Plug). (od38332/2022_2023)
Supplying and fixing 22 to 25W LED, ( PF> 0.96 ,Harmonics > 9%. ) recess mounted round shaped down lighter suitable for low ceiling heights, ceiling should be cut in required shape and make good connection etc complete. (od38655/2022_2023)
Supply & installation of light fittings on flat iron bracket Supply, conveyance, installation, testing and commissioning the light fittings of following types made of CRCA sheet of .5mm thickness complete with all accessories and lamps etc. directly on wall using 2 nos. flat iron brackets made from 25x6mm flat iron, painting the flat iron bracket and giving connections with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS or extending the original wiring and giving connection etc. as required.1200 mm 1X20W LED Lamp with box type fixture. (90.3.22.3)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43). (90.11.1.10)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43). (90.11.1.14)
Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8 + 18) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43). (90.11.1.19)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 6 sq mm with factory made clamp. (90.12.7.39).
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 16 sq mm with factory made clamp. (90.12.7.41)
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required. 4 core 50 sq mm. (90.12.7.44)
Earthing with G.I. earth pipe 2.5 metre long, 40 mm dia including accessories, and<br>providing masonry enclosure with cover plate having locking arrangement and<br>watering pipe etc. with charcoal/coke and salt as required<br> (Dimension of pit should be minimum of 2.5m*0.6m*0.6m). (od38676/2022_2023)
Supplying and fixing 3 Phase Energy meter Syntax Enclosure With Neutral Link. (od39542/2022_2023)
Supplying and providing 63 A Kit Kat fuse on Existing Syntax Box.. (od39461/2022_2023)
Supply and fixing 4pole MCCB sheet steel enclosure on surface /recess along with100 A , 440 V 4 pole MCCB. complete with connections ,testing and commissioning etc, as required. (od39475/2022_2023)
Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.<br>Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 2.00mm CRCA sheet, powder coated (excluding base frame). (90.14.1.1)
Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc. (90.14.2.1)
Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet. (90.14.3.2)
Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board. (90.14.5)
Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required. (90.14.6)
Supply and providing copper earth bus in the panel board. (90.14.7)
Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL. (90.14.10.3)
MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A. (90.14.11.13)
Supply and Installing the following accessories to existing Fabricated MCCB panel Board 1) 1 no LCD display 3 phase 4 wire Kwh panel mount meter with Suitable CT ratings. 2) 1 no Multifunction meter to read V, A, F, PF 3) 3 Nos R Y B Led indication Lamp with toggle switch including connection etc completed. (od40755/ 2022_2023)
Supply and making 32 mm dia GI pipe (medium class) in wall for fixing street light including bending the pipe to the required shape complete as required. (od41710/2022_ 2023)
Supplying and installing integrated 70-80W LED Street light with IP66 protection (PWD approved makes mandatory) With fittings , all accessories and 1.5 meter 3 core 1.5 sq mm WP cable to fix in the Walls of Buildings. (od41711/ 2022_2023)
Supplying and fixing 4 pole sheet steel enclosure on surface / recess along with 40A 4Pole Isolator complete with connections, testing and commissioning etc as required.. (od41834/2022_2023)
supplying and providing following size of electrical grade rubber mat to site location 1000 mm X 2000 mm X 12 mm. etc completed. (od41909/ 2022_ 2023)
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size from wall surface as required. Upto 35 sq. mm. (od42629/2022_2023)
Dismantling of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size from wall surface as required. Up to 35 sq mm and same cable clamping on another wall to connect new MSB. (od42661/2022_2023)
Mahesh KR
gopakumar.kv
SURENDRAN.MR
Nijilesh P
MOHAMMED MUSTHAFA K.
ASIF ELECTRICAL WORKS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_717825.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .